Loading...
610 TIMBER BRIDGE - ICC -ES EVALUATION lb /imbue sEr 2-11, Es S ICC EVALUATION ` SERVICE Most Widely Accepted and Trusted • ICC-ES fictatepyort -- ESR-3375 By__ Reissued August 2014 This report is subject to renewal August 2016. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE pcf. The insulation's liquid components are supplied in PROTECTION nominally 55-gallon drums, labeled as "A" component or Section: 07 21 00—Thermal Insulation "B" component. The insulation components have a shelf life of six months when stored in unopened containers at REPORT HOLDER: temperatures between 70°F(21°C)and 90°F (32°C). SES FOAM 3.2 Surface-burning Characteristics: 4008 LOUETTA ROAD,#538 At a maximum thickness of 4 inches (102 mm) and a SPRING, TEXAS 77388-4405 nominal density of 0.5 pcf, the insulation has a flame- (713)239-0252 spread index of 25 or less and a smoke-developed index of www.sesfoarn.com 450 or less when tested in accordance with ASTM E84. Thicknesses of up to 111/2 inches (292 mm) for wall EVALUATION SUBJECT: cavities and ceiling cavities are recognized based on room corner fire testing in accordance with NFPA 286, when SES FOAM 0.5 lb SPRAY: SPRAY-APPLIED the insulation is covered with a minimum 1/2-inch-thick POLYURETHANE FOAM PLASTIC INSULATION (12.7 mm) gypsum board installed in accordance with the applicable code. 1.0 EVALUATION SCOPE 3.3 Thermal Resistance(R-values): Compliance with the following codes: The insulation has thermal resistance (R-values)at a mean • 2012 and 2009 International Building Code®(IBC) temperature of 75°F(24°C)as shown in Table 1. • 2012 and 2009 International Residential Code®(IRC) 3.4 Air Permeability: • 2012 and 2009 International Energy Conservation The insulation, at a minimum thickness of 3 inches Code®(IECC) (76 mm), is considered air-impermeable in accordance • Other Codes(see Section 8.0) with IRC Section R202, based on testing in accordance with ASTM E283. Properties evaluated: 4.0 INSTALLATION • Surface-burning characteristics 4.1 General: • Physical properties SES Foam 0.5 lb spray insulation must be installed in • Thermal resistance(R-values) accordance with the manufacturer's published installation • Attic and crawl space installation instructions and this report. A copy of the manufacturer's published installation instructions must be available at all • Air permeability times on the jobsite during installation. 2.0 USES 4.2 Application: SES Foam 0.5 lb spray polyurethane foam plastic The insulation is spray-applied at the jobsite using a insulation is used as a nonstructural thermal insulating volumetric positive displacement pump as identified in the material in buildings of Type V-B (IBC) construction, and in SES Foam 0.5 lb spray application manual. The insulation dwellings built under the IRC. The insulation is for use in components must be stored at temperatures between wall cavities and floor/ceiling assemblies, and in attics and 70°F (21°C) and 90°F (32°C) for several days before crawl spaces when installed as described in Section 4.4. application. The insulation must not be used in areas Under the IRC, the insulation may be used as air- that have maximum in-service temperatures greater than impermeable insulation when installed as described in 180°F (82°C). The insulation must not be used in Section 3.4. electrical outlet or junction boxes or in contact with water 3.0 DESCRIPTION (e.g., rain, condensation, ice, snow) or soil. The substrate 3.1 General: must be free of moisture, frost or ice, loose scales, rust, oil, grease or other surface contaminants. The insulation can SES Foam 0.5 lb spray foam insulation is a two- be installed in one pass to the maximum thickness. The component, open cell, one-to-one-by-volume spray-applied spray-applied foam insulation must be protected from polyurethane foam system with a nominal density of 0.5 weather during and after installation. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied as to any f nding or other matter in this report,or as to any product covered by the report. Copyright 0 2014 Page 1 of 3 ESR-3375 I Most Widely Accepted and Trusted Page 2 of 3 4.3 Thermal Barrier: 5.0 CONDITIONS OF USE SES Foam 0.5 lb spray insulation must be separated from The SES Foam 0.5 lb spray polyurethane foam plastic the interior of the building by an approved thermal barrier insulation described in this report complies with, or is a of 1/2-inch-thick (12.7 mm) gypsum wallboard or an suitable alternative to what is specified in, those codes equivalent 15-minute thermal barrier complying with, and listed in Section 1.0 of this report, subject to the following installed in accordance with, IBC Section 2603.4 or IRC conditions: Section R316.4, as applicable. Within an attic or crawl 5.1 The insulation must be installed in accordance with space, installation must be in accordance with Section 4.4. the manufacturer's published installation instructions, 4.4 Attics and Crawl Spaces: this evaluation report and the applicable code. If there are any conflicts between the manufacturer's 4.4.1 Application with a Prescriptive Ignition Barrier: published installation instructions and this report, this When SES Foam 0.5 lb spray is installed within attics and report governs. crawl spaces, where entry is made only for service of 5.2 The insulation must be separated from the interior of the utilities, an ignition barrier must be installed in accordance building by an approved 15 minute thermal barrier, as with IBC Section 2603.4.1.6 or IRC Section R316.5.3 or described in Section 4.3. Installation in an attic or R316.5.4, as applicable. The ignition barrier must be consistent with the requirements for the type of crawl space must be as described in Section 4.4. construction required by the applicable code, and must be 5.3 The insulation must not exceed the thicknesses noted installed in a manner so that the foam plastic insulation is in Sections 3.2 and 4.4. not exposed. SES Foam 0.5 lb spray insulation at a 5.4 The insulation must be protected from exposure to the minimum thickness of 3 inches(76 mm) may be installed in weather during and after application. unvented attics in accordance with 2012 IRC Section R806.5 (2009 IRC Section R806.4), as applicable. 5.5 The insulation must be applied by contractors certified by SES Foam. 4.4.2 Application without a Prescriptive Ignition Barrier: Where the spray applied insulation is installed in 5.6 Use of the insulation in areas where the probability of accordance with this section (Section 4.4.2) or Section termite infestation is "very heavy" must be in 4.4.3,the following conditions apply: accordance with 2012 IBC Section 2603.9 (2009 IBC Section 2603.8)or IRC Section R318.4, as applicable. a) Entry to the attic or crawl space is to service utilities, 5.7 Jobsite certification and labeling of the insulation must and no storage is permitted. comply with IRC Sections N1101.4 and N1101.4.1 b) There are no interconnected attic or crawl space and IECC Sections R303.1.1 and 303.1.1.1, as areas. applicable. c) Air in the attic or crawl space is not circulated to other 5.8 SES Foam 0.5 lb spray polyurethane foam plastic parts of the building. insulation is produced in St. Louis, Missouri, under a quality control program with inspections by ICC-ES. d) Attic ventilation is provided when required by IBC 6.0 EVIDENCE SUBMITTED Section 1203.2 or IRC Section R806, except when air-impermeable insulation is permitted in unvented 6.1 Data in accordance with the ICC-ES Acceptance attics in accordance with 2012 IRC Section R806.5 or Criteria for Spray-applied Foam Plastic Insulation 2009 IRC Section R806.4. Under-floor (crawl space) (AC377), dated June 2012, including reports of tests ventilation is provided when required by IBC Section in accordance with Appendix X of AC377. 1203.3 or IRC Section R408.1, as applicable. 6.2 Report of room corner fire testing in accordance with e) Combustion air is provided in accordance with NFPA 286. International Mechanical Code Section 701. 6.3 Report of air permeance testing in accordance with In attics, the insulation may be spray-applied to the ASTM E283. underside of roof sheathing or roof rafters, and/or vertical 7.0 IDENTIFICATION surfaces, and in crawl spaces the insulation may be spray Components of the SES Foam 0.5 lb spray polyurethane applied to the underside of floors and/or vertical surfaces as described in this section. The thickness of the foam foam plastic insulation are identified with the plastic applied to the underside of the top of the space manufacturer's name (SES Foam) and address; the date must not exceed 12 inches (305 mm). The thickness of the foam plastic applied to vertical surfaces must not exceed of manufacture or the lot number; the product trade name(SES Foam 0.5 lb); the mixing instructions; the density;the 111/2 inches (292 mm). The foam plastic may be installed flame spread and smoke developed indices, and the without a covering or coating. The insulation may be evaluation report number(ESR-3375). installed in unvented attics in accordance with 2012 IRC 8.0 OTHER CODES Section R806.5 (2009 IRC Section R806.4). The ignition In addition to the codes referenced in Section 1.0, the barrier in accordance with IBC Section 2603.4.1.6 or IRC products in the report were evaluated for compliance with Section R316.5.3 may be omitted. the requirements of the following codes: 4.4.3 Use on Attic Floors: SES Foam 0.5 lb spray • 2006 International Building Code®(2006 IBC) insulation may be installed exposed at a maximum 2006 International Residential Code®(2006 IBC) thickness of 111/2 inches (292 mm) between joists in attic • floors. The ignition barrier in accordance with IBC Section • 2006 and 2003 International Energy Conservation 2603.4.1.6 or IRC Section R316.5.3 may be omitted. The Code®(2006 IECC) insulation must be separated from the interior of the building by an approved thermal barrier. ESR-3375 I Most Widely Accepted and Trusted Page 3 of 3 The products comply with the above-mentioned codes as provided in accordance with Sections 701 and 703 of described in Sections 2.0 through 7.0 of this report, with the 2006 IECC. revisions as noted below: • Protection against Termites: See Section 5.6, except • Application with a Prescriptive Thermal Barrier: See use of the insulation in areas where the probability of Section 4.3, except the approved thermal barrier must termite infestation if"very heavy" must be in accordance be installed in accordance with Section R314.4 of the with Section R320.5 of the 2006 IRC. 2006 IRC. • Jobsite Certification and Labeling: See Section 5.7, • Application with a Prescriptive Ignition Barrier: See except jobsite certification and labeling must comply Section 4.4.1, except an ignition barrier must be with Sections 102.1.1 and 102.1.1.1, as applicable, of installed in accordance with Section R314.5.3 or the 2006 IECC. R314.5.4 of the 2006 IRC. • Application without a Prescriptive Ignition Barrier: See Section 4.4.2, except that combustion air is TABLE 1—THERMAL RESISTANCE(R-VALUES'') THICKNESS(inches) R-VALUE(°F.ft2.h/Btu) 1 4.0 2 7.6 3 11 3.5 13 4 15 5 19 6 22 7 26 8 30 9 33 10 37 11 41 12 44 For SI:1 inch=25.4 mm, 1°F•ft2•h/Btu=0.176 110K-m2/W. 1R-values are calculated based on tested K values at 1-and 3.5-inch thicknesses. 7R-values greater than 10 are rounded to the nearest whole number. • ICC EVALUATION `,,.• SERVICE Most Widely Accepted and Trusted ICC-ES VAR Environmental Report VAR-1030* Reissued July 2013 This report is subject to renewal September 1, 2015. www.icc-es.orqlep 1 800-423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE high-pressure, plural component SPF application PROTECTION equipment. The bio-based content is as set forth in Table 1 Section: 07 21 00—Thermal Insulation of this report. R 4.0 CONDITIONS REPORT HOLDER: 4.1 Code Compliance: SES FOAM See ICC-ES report ESR-3375 for compliance of the SES 4008 LOUETTA ROAD,#538 Foam 0.5 lb Foam S Polyurethane Foam Plastic Insulation SPRING, TEXAS 77388-4405 with code requirements. (713)239-0252 www.sesfoam.com 4.2 Green Codes, Standards and Rating Systems Eligibility: EVALUATION SUBJECT: The information presented in Tables 2 through 5 of this SES FOAM 0.5 lb SPRAY POLYURETHANE FOAM report provides a matrix of areas of evaluation and corresponding limitations and/or additional project-specific PLASTIC INSULATION requirements, and offers benefits to individuals who are 1.0 EVALUATION SCOPE assessing eligibility for compliance. The final interpretation of the specific requirements of the Compliance with the following environmental criteria: code rests with the Authority Having Jurisdiction. ICC-ES Environmental Criteria for Determination of Compliance for items noted as "Verified Attribute" is Bio-based Material Content(EC102), dated March 1, 2012. subject to any conditions noted in the tables. Decisions on Compliance eligibility with the applicable sections of compliance for those items noted as"Eligible for Points" in the following codes and standards: Tables 2 through 5 rests with the user of this report, and those items are subject to the conditions noted. The user is • 2012 International Green Construction Coder"' (IgCC) advised of the project-specific provisions that may be (see Table 2 for details) contingent upon meeting specific conditions, and the • ASHRAE Standard 189.1 – 2009 (see Table 3 for verification of those conditions is outside the scope of this details) report. • National Green Building Standard (ICC 700-2008) (see Due to the variability of costs and volume, the bio-based Table 4 for details) content percentage listed in this report is based upon weight (mass). The use of cost or volume as the method • ANSI/GBI 01-2010, Green Building Assessment for calculation is outside the scope of this report. Protocol for Commercial Buildings (see Table 5 for details) 5.0 BASIS OF EVALUATION 2.0 USES The information in this report, including the "Verified Attributes," is based upon submission of documentation SES Foam 0.5 lb Foam S Polyurethane Foam Plastic demonstrating compliance with the requirements set forth Insulation is used as nonstructural thermal insulating in ICC-ES EC102. (Evaluation applies to IgCC Section material in wall cavities, floor/ceiling assemblies, or in 505.2.4, item 3; ASHRAE 189.1 Section 9.4.1.3; ICC 700 attics and crawl spaces. See ICC-ES report ESR-3375 for Section 606.1; ANSI/GBI-01 Section 10.1.2.2.) more information on uses and applications. 6.0 IDENTIFICATION 3.0 DESCRIPTION Containers of SES Foam 0.5 lb Foam S Polyurethane SES Foam 0.5 lb spray-applied polyurethane foam plastic Foam Plastic Insulation are identified by a label bearing the insulation is a two-component, open-cell, water-blown, SES Foam name and address, product name, spray-applied polyurethane foam (SPF) with a nominal manufacturing date, manufacturing location and the VAR density of 0.5 lb/ft3. The foam is sprayed in place using Environmental Report number(VAR-1030). `Corrected May 2014 ICC-ES Verification of Attributes Reports are issued under the ICC-ES VAR Environmental Program.These reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,I.LC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. m1uw14 atu�r Copyright 0 2014 Page 1 of 2 VAR-1030 Most Widely Accepted and Trusted Page 2 of 2 • TABLE 1-810-BASED MATERIAL CONTENT SUMMARY PRODUCT NAME % MEAN BIO-BASED CONTENT METHOD OF DETERMINATION SES Foam 0.5 lb Spray Polyurethane Foam Plastic Insulation 17%(+/-3%)' ASTM D6866 1I Note: 'Based on precision and bias cited in ASTM D6866. TABLES 2 THROUGH 5 Section I Possible Number Section Intent Points Conditions Of Use To Qualify For Points Finding TABLE 2—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2012 INTERNATIONAL GREEN CONSTRUCTION CODE Bio-based materials shall be those materials that comply with one or more of the following: 505.2.4 Bio-based content N/A 3.The requirements of USDA 7CFR Part 2902. • Note: USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%). SES Foam 0.5 lb Spray exceeds this minimum. TABLE 3—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2009 ASHRAE STANDARD 189.1 A minimum of 5%of building materials used,based on cost,shall be biobased products. Biobased products shall comply with the minimum biobased contents of the USDA's Designation of Biobased Items for Federal Procurement[7 CFR Part 2902],contain the 9.4.1.3 Biobased products N/A `USDA Certified Biobased Product"label,or be composed of solid wood,engineered • wood,bamboo,wool,cotton,cork,agricultural fibers,or other biobased materials with at least 50%biobased content. Note: USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%). SES Foam 0.5 lb Spray exceeds this minimum. TABLE 4—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2008 NATIONAL GREEN BUILDING STANDARD (ICC 700) The following biobased products are used: (h)products with the minimum biobased contents of the USDA 7 CFR Part 2902 606.1 Biobased products 3 (i)other biobased materials with a minimum of 50 percent biobased content(by weight • 8 max or volume) Note: USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%). SES Foam 0.5 lb Spray exceeds this minimum. TABLE 5—SUMMARY OF AREA OF ELIGIBILITY WITH THE ANSI/GBI–01 (2010)STANDARD Bio-based products accounted for 1%or more of the materials used in the building. Percentage=100 x A±B,where: A=Total cost or weight of bio-based products B=Total cost or weight of all building products 10.1.2.2 Materials content– 1 Cost or weight must be used consistently • Assemblies 7 max For USDA-designated products, products meeting or exceeding USDA's bio-based content,criteria or qualifying as USDA"BioPreferred"were used. Note: USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%). SES Foam 0.5 lb Spray exceeds this minimum. • =Verified attribute ICC EVALUATION ��• SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3375 Seal and Insulate with ENERGY STAR®Supplement Reissued August 2014 This report is subject to renewal August 2016. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD,#538 SPRING, TEXAS 77388-4405 (713)239-0252 www.sesfoam.com EVALUATION SUBJECT: SES FOAM 0.5 lb SPRAY: SPRAY-APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1.0 EVALUATION SCOPE Conformance to the following: Seal and Insulate with ENERGY STAR® Program—Definitions and Testing Requirements for Residential Insulation, Version 1.0 Properties evaluated: • Thermal resistance • Surface-burning characteristics 2.0 PURPOSE OF THIS SUPPLEMENT This supplement is issued to certify that the insulation products described in Sections 2.0 through 8.0 of the master report ESR-3375 have been reviewed for compliance with the requirements of the Seal and Insulate with ENERGY STAR® Program, as set forth in the document Definitions and Testing Requirements for Residential Insulation, Version 1.0. The insulation product covered by this supplement is defined as"Spray or Pour Foam Insulation." The requirements for testing laboratory qualification and product sampling, as well as the specific material and test standards and editions used in this evaluation, are as set forth in the applicable documentation noted in Section 6.0 of the master evaluation report. 3.0 DEFINITIONS The following definitions are from Definitions and Testing Requirements for Residential Insulation, Version 1.0, and are applicable to the subject of this report. 3.1 General Definitions: Insulation: Any material mainly used to slow down heat flow. It may be mineral or organic, fibrous, cellular, or reflective (aluminum foil). It may be in rigid, semi-rigid, flexible, or loose-fill form. 3.2 Insulation Product Definitions: Spray or Pour Foam Insulation:A thermal insulating material that is sprayed or poured(as a gel or foamy liquid) into place, and expands or sets into a cellular foam and cures at the point of installation through a chemical reaction. Foamed materials include, but are not limited to polyurethane, polyisocyanurate, phenolic, and cementitious insulation. 3.3 Insulation Performance Definitions: R-value: The inverse of the time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces, under steady state conditions, per unit area. For the purposes of the Seal and Insulate with ENERGY STAR®program, Imperial units will only be accepted[(h•ft2•°F)1Btu]. ICC-ES Evaluation Reports are not to he construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC.express or implied as to any finding or other matter in this report,or as to any product covered by the report. Copyright 0 2014 Page 1 of 6 ESR-3375 I Most Widely Accepted and Trusted Page 2 of 6 Smoke-Development Index: The characteristic of a material to emit smoke when exposed to flame or fire compared to red oak and inorganic cement. Flame-Spread Index: The characteristic of a material to resist the spreading of flames when exposed to flame or fire compared to red oak and inorganic cement. 3.4 Thermal Resistance: The insulation has the thermal resistance R-values as noted in Table 1 of ESR-3375, based upon testing. 3.5 Installation: 3.5.1 General: The installation of the insulation must be in accordance with the requirements set forth in Sections 4.0 and 5.0 (as applicable)of ESR-3375. The insulation is manufactured on-site by spray polyurethane foam applicators meeting the qualification requirements of SES Foam. The following information on personal protective equipment and ventilation requirements is reprinted from the SES Foam published installation instructions: "F. SAFETY 3. PERSONAL PROTECTIVE EQUIPMENT(PPE): a. Skin: Wear gloves, coveralls, apron and boots as necessary to prevent contact of liquid components or partially-cured SPF with skin. When handling liquid components, gloves should be made of nitrile, neoprene, butyl or PVC. b. Eyes: Protect eyes while handling liquid components or spraying with safety goggles or safety goggles and a face shield. During spray application, eye protection may be provided by a full-face or hood respirator. c. Respiration: Firms engaged in the application of SES Foam systems must have a written respiratory protection program for employees engaged in handling or applying SES Foam materials. Depending on the situation, respiratory protection may include dust masks, air-purifying respirators (APR), powered air-purifying respirators (PAPR), or supplied- air respirators(SAR). 4. VENTILATION: Provide ventilation and other engineering controls to exhaust vapors from work areas and to protect building occupants and other trades." 3.5.2 Occupancy Time after Installation: The re-entry or re-occupancy time shall be in accordance with the manufacturer's installation instructions, which state the following: "E. RE-ENTRY SES Foam 0.5 lb Spray reacts and cures within seconds of application. Re-entry times will vary depending on factors including ventilation. Typically, ventilation is continued for 24 hours following the conclusion of spray application and re-entry may occur at that time." 3.5.3 Figures: The figures shown represent general installations of the insulation in the following applications: above-grade wall, below-grade wall, vented and unvented crawl space, unvented cathedral ceiling, and vented and unvented attic. These figures are for illustration purposes and are not to be construed or used as construction documents. This supplement expires concurrently with the master report, reissued August 2014. ESR-3375 I Most Widely Accepted and Trusted Page 3 of 6 •000"00°"00°0p0' * 1ih7L1 %00000_ 0°0_000 0.0°°00°°00°000 0 o° 00 00000 o o 0 X000 0 0 0 000 '°°0°C'0 0 00°0, _ 00. o' o. oo 1.1110 oo.,....„1„..._ _....—. • - o•- 0 . X00°000°. 00:.(0);0°:0., Interior Partition 00°00°°0 '00°00°°, X000° 00• �-----__Interior Finished Surface •°00000°000 (112-inch Sheetrock) 00p0000, 00°000°0 •000°0°°. .00°000'• 0• °00 0°' SES Foam 0.5 lb Spray X_,00_00•0 0 .n0°.-o0 ,0000°OvO. 000000°0 Exterior Sheathing •o 0°go.0 .• 0000o000 SES FOAM 0.5 LB SPRAY ABOVE GRADE WALL INSULATION SES 05-1 071812 ESR-3375 I Most Widely Accepted and Trusted Page 4 of 6 00� I Masonry Block �< > (Typical)----.— 1/ ,/ Interior Finish Surface (1/2-inch Sheetrock) Of :- ,.....::.::.. 2"x 4" Studs ��,f� SES Foam 0.5 lb Spray,:„.....,... .,..,..,..., „„..,....,,,,,... . .• • FOAM 0.5 LB SPRAY I BELOW GRADE WALL INSULATION I SES O5-2 I 071812 (Insulation on Interior Side of Wall) Baffle to provide / � air %/ insulation between on and roof // Barrier* deck. /// (as required by local code) �.0000x•, oo°o°o°o°0°0°0000000000000000 • o 0 0 0 0 0 0 0 0 0 x 0 0 0 0 0 0 0 0 0 0 0 0°0°0°0°0°0°0°0°0°0° 00°0°0°0°0°0°0°0°0°0°0°0• 0 0 0 0 0 0 0 0 0 0• x 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 x 0 0 0 0 0 0 0 0 0 0 ' o000g. °°°°°°° gogogo0g SES Foam 0.5 lb Spray °°°°°°°° i iiiiiii iii i i iii i ii i i i i i ii i i i. 0 0,.0 x 0. x0000000 g .' ..°0°0°0° 0 0 000o00o0 0.00.0x0 a 0°0°000 °o°o°o° 0 0 0 0 ' ° ° ° Vented Soffit g:o g:o goo o 000.0.° g0g0gQg0 . . . to.°.°.°0 'Where attic entry is for the bg:g:oo ry °.°0° ° service of utilities only,thermal SES Foam 0.5 lb Spray °o g:°:g:g and igniton barrier on the attic 0° 00°0 side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY VENTED ATTIC:FLOOR/SOFFIT SES 05-3 071812 ESR-3375 I Most Widely Accepted and Trusted Page 5 of 6 o Subfloor i _ SES Foam 0.5 Ib Spray r. °o°o ° °°°__ � o° ° °° '' °° °° Header-- g°ggg°ooggg.g. °°°°°°o war4 ,°° oo °g C A Sill— 1�� •-■gosoo° Joist Floor Cross Section ►�������4 Thermal Barrier* ko. . . A as required b Exterior Grade ��:+* (as code) by /\\\//\\\/\\\\%���A iiiii4 ►��������4 6"Min ►11114 Footer 4 Vapor Barrier ••.. ' '' z \//\�%/\`%/\• //\\//\\// 'Where crawlspace entry is for the ' + / service of utilities only,thermal and igniton barrier on the crawlspace side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY CRAWLSPACE:VENTED SES 05-4 071812 Subfloor °g°g °°°°°°°°°°°°° ° °g°°g . Header +e°°° °°°°e e' L °08 ° ,ggoggegk ..iii-4 Sill ►�--��-4::.: Joist ►������� :I'M i% ►��������g ogg Thermal Barrier' °gggg — (as required by Exterior Grade --.--Ngggog local code) „/c\//�"\///.\\ �������4 00° ••••.°g SES Foam 0.5 lb Spray• j��•'ii%o%o% ►��...lo ••••I ..-q•, • Footer` ►��� .6 "Min Vapor B.rrier• .. .' / \///\ 'Where crawlspace entry is for the service of utilities only,thermal and igniton barrier on the crawlspace side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY CRAWLSPACE:UNVENTED SES 05-5 071812 ESR-3375 I Most Widely Accepted and Trusted Page 6 of 6 Note:In cold climates,embed metal connector plates in spray foam to prevent winter-time condensation. °o °000�'.00000. °oao° i 000• SES Foam 0.5 lb Spray 000°/o44 k Roof Sheathing o oo° 2�i Truss Top Cord! ..0000 °?Rafter °0000°o°°'oo �{;#�__ nnnnnn nnnnnn I1- Thermal Barrier' (as required by local code) . Note:Local building code may V require the use of a vapor retarder 'n cold climate zones. Ceiling/Thermal Barrier 'Where attic entry is for the as required by local building code. service of utilities only,thermal and igniton barrier on the attic side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY UNVENTED ATTIC/INSULATED ROOF DECK SES 05-6 071812 1o0 SES Foam 0.5 lb Spray / 000 to specified thickness. O O i 0 Roof Sheathing •O O • 000000. • 0 0 0 0 0 • Thermal Barrier as Rafter 0 O O O ' required by code. 0 0 � Note:The local building code may require the installation of a vapor barrier in cold climate zones. V SES FOAM 0.5 LB SPRAY I CATHEDRAL CEILING SES 05-7 I 071912