Loading...
2321 MAYPORT RD - HVAC TEST REPORT HTB NEBB CERTIFIED TEST, ADJUST AND BALANCE REPORT DATE: 7/15/2015 PROJECT Dollar Tree ADDRESS 2031 Mayport Road Atlantic Beach, Florida 32233 ARCHITECT Not Specified ENGINEER Not Specified HVAC CONTRACTOR Progressive Air HOLISTIC TEST & BALANCE 3614 LENOX AVE. JACKSONVILLE, FL 32254 (904) 900-1484 om 1 r -�1 - LOYD E.UFFELDAAN L CERTIFICATION 2701 Exp.3/31/17 9'�� �0`°g l4 - � rl � .-� - .5 6, n°'M(iron\c 7 Zszt Table of Contents Abbreviation Sheet 1 RTU-1 2 RTU-1 Grille Sheet 3 RTU-2 4 RTU-2 Grille Sheet 5 RTU-3 6 RTU-3 Grille Sheet 7 RTU-4 8 RTU-4 Grille Sheet 9 RTU-5 10 RTU-5 Grille Sheet 11 Duct-Traverse Totals 12 EF-1 13 EF-1 Grille Sheet 14 Instrument Calibration Report 15 HOLISTIC TEST & BALANCE 3614 Lenox Avenue Jacksonville, Florida 32254 (904) 900-1484 Abbreviations and Terms A/C or ACU Air Conditioner Unit Max Maximum AHU Air Handling Unit MBH BTU's per hour Amp(s) Amperage Min. Minimum BHP Brake Horse Power NA Not Applicable BTU British Thermal Unit NI Not Installed CFM Cubic Feet per Minute NS Not Specified CFLA Corrected Full Load Amperage # Number Comp. Compressor OA Outside Air DB Dry Bulb Ph. Phase Diff. Differential P.D. Pressure Drop EF Exhaust Fan PSI Pounds Per Square Inch Elev. Elevator Qty Quantity Ent. Entering Req Required Equip. Equipment RPM Rotations Per Minute FLA Full Load Amps SF Safety Factor FTU Fan Terminal Unit S.P. Static Pressure Ft. Feet Sq Square G.C. General Contractor Svc Service GPM Gallons Per Minute TAB Test and Balance HP Horse Power Temp Temperature Hz Hertz VAV Variable Air Volume Inches VEL Velocity KW Kilowatt WB Wet Bulb lb(s) Pound(s) WG Water Gauge Lvg. Leaving Page 1 HOLISTIC TEST & BALANCE PROJECT: Dollar Tree DATE: 7/14/2015 BY: NLU LOCATION: Atlantic Beach, Florida SYSTEM: RTU-1 SPECIFICATIONS: FAN CFM: 2850 TSP/ESP: /1 .0 BHP/HP: /NS RPM: NS OA CFM: 700 COOLING: MBH: 93.3 TYPE: DX EAT DB/WB: 80.0/67.0 LAT DB/WB: NS HEATING: KW: 12.0 TEST DATA: UNIT: Carrier SIZE: 50HC-DO8A2P5AF10 SER#: 0415P78778 MOTOR: Marathon HP: NS RPM: 1725 VOLT: 208-230/3v FLA: 6.9 TEST VOLT: 210/3v CORR. FLA: 6.9 MISC: HTR SIZE: RATING: RUN. AMPS: 4.2, 4.2, 4.6 BHP: NA FAN CFM: 3045 TSP/ESP: /0.98 RPM: 733 OA CFM: 750 COIL: EAT DB LAT DB DIFF TYPE MBH COOLING: 75.8/65.2 56.2/55.7 6.56 DX 86.9 HEATING: COMP. FLA: 2 @ 13.6A @ 208-230/3v TEST: 12.9A + 13.2A @ 210/3v COND. FLA: 2 @ 1.5A @ 208-230/1v TEST: 1 .2A + 1 .2A @ 210/1v LRA: 83.0 (2) ELECT HT. 31.8A @ 210/3v= 11 .6 KW REMARKS: Supply Air - Return Air = Outside Air Per Design Page 2 HOLISTIC TEST & BALANCE DIFFUSER AND GRILLE TEST REPORT PROJECT: Dollar Tree LOCATION: Atlantic Beach, Florida SYSTEM: RTU-1 AREA SERVED: Retail DESIGN FINAL LOCATION # TYPE SIZE AK TEST 1 MEN Percent Variance VEL CFM Supply Retail 1 A 12" Hood 450 490 109% Office 2 B 8" Hood 150 160 107% Retail 3 A 12" Hood 450 480 107% Retail 4 A 12" Hood 450 485 108% Retail 5 A 12" Hood 450 480 107% Retail 6 A 12" Hood 450 470 104% Retail 7 A 12" Hood 450 480 107% 2850 3045 107% Return Retail 1 D 36"x14" Hood 2850 2300 81% DATE: 7/14/2015 BY: NLU Page 3 HOLISTIC TEST & BALANCE PROJECT: Dollar Tree DATE: 7/14/2015 BY: NLU LOCATION: Atlantic Beach, Florida SYSTEM: RTU-2 SPECIFICATIONS: FAN CFM: 2800 TSP/ESP: /1.0 BHP/HP: /NS RPM: NS OA CFM: 700 COOLING: MBH: 93.3 TYPE: DX EAT DB/WB: 80.0/67.0 LAT DB/WB: NS HEATING: KW: 12.0 TEST DATA: UNIT: Carrier SIZE: 50HC-DO8A2P5A0F10 SER#: 5014P76782 MOTOR: Marathon HP: NS RPM: 1725 VOLT: 208-230/3v FLA: 6.9 TEST VOLT: 210/3v CORR. FLA: 6.9 MISC: HTR SIZE: RATING: RUN. AMPS: 4.1, 4.4, 4.0 BHP: NA FAN CFM: 2910 TSP/ESP: /0.94 RPM: 715 OA CFM: 740 COIL: EAT DB LAT DB DIFF TYPE MBH COOLING: 74.8/65.0 56.2/55.3 6.65 DX 87.1 HEATING: COMP. FLA: 2 @ 13.6A @ 208-230/3v TEST: 13.0A + 12.5A @ 210/3v COND. FLA: 2 @ 1.5A @ 208-230/1v TEST: 1.1A + 1.3A @ 210/1v LRA: 83.0 (2) ELECT HT. 32.0A @ 210/3v= 11 .6 KW REMARKS: Page 4 HOLISTIC TEST & BALANCE DIFFUSER AND GRILLE TEST REPORT PROJECT: Dollar Tree LOCATION: Atlantic Beach, Florida SYSTEM: RTU-2 AREA SERVED: Retail DESIGN FINAL LOCATION # TYPE SIZE AK TEST 1 Percent Variance VEL CFM VEL 1 CFM , Supply Retail 1 A 12" Hood 500 470 94% Office 2 A 12" Hood 500 510 102% Retail 3 A 12" Hood 450 490 109% Retail 4 A 12" Hood 450 470 104% Retail 5 A 12" Hood 450 490 109% Retail 6 A 12" Hood 450 480 107% 2800 2910 104% Return Retail 1 D 36"x14" Hood 2800 2150 77% DATE: 7/14/2015 BY: NLU Page 5 HOLISTIC TEST & BALANCE PROJECT: Dollar Tree DATE: 7/14/2015 BY: NLU LOCATION: Atlantic Beach, Florida SYSTEM: RTU-3 SPECIFICATIONS: FAN CFM: 2400 TSP/ESP: /1.0 BHP/HP: /NS RPM: NS OA CFM: 500 COOLING: MBH: 75.2 TYPE: DX EAT DB/WB: 80.0/67.0 LAT DB/WB: NS HEATING: KW: 12.0 TEST DATA: UNIT: Carrier SIZE: 50HC-A07A2P5A0F1 F0 SER#: 0915P61536 MOTOR: Marathon HP: NS RPM: 1725 VOLT: 208-230/3v FLA: 6.9 TEST VOLT: 210/3v CORR. FLA: 6.9 MISC: HTR SIZE: RATING: RUN. AMPS: 4.5, 4.3, 4.6 BHP: NA FAN CFM: 2610 TSP/ESP: /0.98 RPM: 735 OA CFM: 525 COIL: EAT DB LAT DB DIFF TYPE MBH COOLING: 74.4/65.5 56.1/55.3 7.04 DX 82.7 HEATING: COMP. FLA: 1 @ 19.0A @ 208-230/3v TEST: 18.3A @ 210/3v COND. FLA: 2 @ 1.5A @ 208-230/1v TEST: 1 .1A + 1 .3A @ 210/1v LRA: 123.0 ELECT HT. 32.0A @ 210/3v= 11 .6 KW REMARKS: Page 6 HOLISTIC TEST & BALANCE DIFFUSER AND GRILLE TEST REPORT PROJECT: Dollar Tree LOCATION: Atlantic Beach, Florida SYSTEM: RTU-3 AREA SERVED: Retail DESIGN FINAL LOCATION # TYPE SIZE AK TEST 1 Percent Variance VEL CFM VEL CFM Supply Retail 1 A 12" Hood 400 440 110% Retail 2 A 12" Hood 400 430 108% Retail 3 A 12" Hood 400 490 123% Retail 4 A 12" Hood 400 430 108% Retail 5 A 12" Hood 400 420 105% Retail 6 A 12" Hood 400 400 100% 0 2400 2610 109% Return Retail 1 G 26"x14" Hood 1400 1250 89% Retail 2 G 22"x22" Hood 500 440 88% Retail 3 G 22"x22" Hood 500 440 88% 2400 2130 89% DATE: 7/14/2015 BY: NLU Page 7 HOLISTIC TEST & BALANCE PROJECT: Dollar Tree DATE: 7/14/2015 BY: NLU LOCATION: Atlantic Beach, Florida SYSTEM: RTU-4 SPECIFICATIONS: FAN CFM: 2400 TSP/ESP: /1.0 BHP/HP: /NS RPM: NS OA CFM: 500 COOLING: MBH: 75.2 TYPE: DX EAT DB/WB: 80.0/67.0 LAT DB/WB: NS HEATING: KW: 12.0 TEST DATA: UNIT: Carrier SIZE: 50HC-A07A2P50F1 F0 SER#: 5114P77025 MOTOR: Marathon HP: NS RPM: 1725 VOLT: 208-230/3v FLA: 6.9 TEST VOLT: 210/3v CORR. FLA: 6.9 MISC: HTR SIZE: RATING: RUN. AMPS: 4.6, 4.9, 4.5 BHP: NA FAN CFM: 2490 TSP/ESP: /0.95 RPM: 918 OA CFM: 540 COIL: EAT DB LAT DB DIFF TYPE MBH COOLING: 75.2/65.5 56.3/55.5 6.92 DX 77.5 HEATING: COMP. FLA: 1 @ 19.0A @ 208-230/3v TEST: 18.0A @ 210/3v COND. FLA: 2 @ 1.5A @ 208-230/1v TEST: 1.4A+ 1.2A @ 210/1v LRA: 123.0 ELECT HT. 31.7A @ 210/3v= 11.5 KW REMARKS: Page 8 HOLISTIC TEST & BALANCE DIFFUSER AND GRILLE TEST REPORT PROJECT: Dollar Tree LOCATION: Atlantic Beach, Florida SYSTEM: RTU-4 AREA SERVED: Retail DESIGN FINAL LOCATION # TYPE SIZE AK TEST 1 Percent Variance VEL CFM VEL CFM Supply Retail 1 A 12" Hood 400 390 98% Retail 2 A 12" Hood 400 410 103% Retail 3 A 12" Hood 400 430 108% Retail 4 A 12" Hood 400 410 103% Retail 5 A 12" Hood 400 430 108% Retail 6 A 12" Hood 400 420 105% 2400 2490 104% Return Retail 1 G 26"x14" Hood 2400 1925 80% DATE: 7/14/2015 BY: NLU Page 9 HOLISTIC TEST & BALANCE PROJECT: Dollar Tree DATE: 7/14/2015 BY: NLU LOCATION: Atlantic Beach, Florida SYSTEM: RTU-5 SPECIFICATIONS: FAN CFM: 2000 TSP/ESP: /1.0 BHP/HP: /NS RPM: NS OA CFM: 300 COOLING: MBH: 60.4 TYPE: DX EAT DB/WB: 80.0/67.0 LAT DB/WB: NS HEATING: KW: 12.0 TEST DATA: UNIT: Carrier SIZE: 50HC-A06A2P5A0F1 F0 SER#: 0913C85098 MOTOR: Marathon HP: NS RPM: 1725 VOLT: 208-230/3v FLA: 6.9 TEST VOLT: 210/3v CORR. FLA: 6.9 MISC: HTR SIZE: RATING: RUN. AMPS: 3.7, 4.0, 3.6 BHP: NA FAN CFM: 2091 TSP/ESP: /0.93 RPM: 1090 OA CFM: 325 COIL: EAT DB LAT DB DIFF TYPE MBH COOLING: 75.5/65.0 56.1/55.5 6.53 DX 61.4 HEATING: COMP. FLA: 1 @ 15.9A @ 208-230/3v TEST: 15.0A @ 210/3v COND. FLA: 1 @ 1.4A @ 208-230/1v TEST: 1.1A @ 210/1v LRA: 110.0 ELECT HT. 31.9A @ 210/3v= 11.6 KW REMARKS: Page 10 HOLISTIC TEST & BALANCE DIFFUSER AND GRILLE TEST REPORT PROJECT: Dollar Tree LOCATION: Atlantic Beach, Florida Restrooms, Hallway, Stockroom, SYSTEM: RTU-5 AREA SERVED: and Employee Area DESIGN FINAL LOCATION # TYPE SIZE AK TEST 1 Percent Variance VEL CFM VEL I CFM Supply Toilet 1 F 6" Hood 50 50 100% Hallway 2 F 6" Hood 100 95 95% Toilet 3 F 6" Hood 50 50 100% Stockroom 4 C 14"x10" 0.97 371 360 405 393 109% Stockroom 5 C 14"x10" 0.97 371 360 390 378 105% Stockroom 6 C 14"x10" 0.97 371 360 390 378 105% Stockroom 7 C 14"x10" 0.97 371 360 380 369 103% Employee Area 8 C 14"x10" 0.97 371 360 390 378 105% 2000 2091 105% DATE: 7/14/2015 BY: Page 1 r----- HOLISTIC TEST & BALANCE DUCT TRAVERSE SHEET ZONE TOTALS DATE: 7/14/2015 PROJECT: Dollar Tree LOCATION Atlantic Beach, Florida TRAVERSE DUCT REQUIRED FINAL SIZE AREA SYSTEM LOCATION VEL CFM VEL PRES. VEL CFM RTU-1 OA 36"x20" 5.0 140 700 150 750 RTU-2 OA 36"x20" 5.0 140 700 148 740 RTU-3 OA 36"x20" 5.0 100 500 105 525 RTU-4 OA 36"x20" 5.0 100 500 108 540 RTU-5 OA 30"x16" 5.0 60 300 65 325 REMARKS: Page 12 HOLISTIC TEST & BALANCE PROJECT: Dollar Tree DATE: 7/14/2015 LOCATION: Atlantic Beach, Florida FAN TEST SHEET SPECIFIED EF-1 LOCATION Restrooms TOTAL CFM 200 FAN RPM 1360 TOTAL SP 0.25 MOTOR BHP 71.3 KW TEST MANUFACTURER Greenheck MODEL # CSP-A200 SERIAL # 1418683 MOTOR MFG Fasco MOTOR HP NS MOTOR RPM 900 MOTOR VOLTS 115/1v MOTOR F.L.A. 0.54A RUN AMPS 0.49A LINE VOLTAGE 120/1v TOTAL CFM 190 FAM RPM 620 TOTAL S.P. 0.20 NOTES: Page 13 HOLISTIC TEST & BALANCE DIFFUSER AND GRILLE TEST REPORT PROJECT: Dollar Tree LOCATION: Atlantic Beach, Florida SYSTEM: EF-1 AREA SERVED: Toilets DESIGN FINAL LOCATION # TYPE SIZE AK TEST 1 Percent Variance VEL CFM VEL CFM Men's Restroom 1 E 10"x10" Hood 100 90 90% Women's Restroom 2 E 10"x10" Hood 100 100 100% 200 190 95% DATE: 7/14/2015 BY: NLU Page 14 NEBB INSTRUMENT CALIBRATION REPORT INSTRUMENT SERIAL # APPLICATION CALIBRATION TEST DATE Shortridge Hood 860C/M11557 Direct Reading 10/1/2014 Tachometer 634-513-044 Direct Reading 10/1/2014 Thermometer Cooper/ SRH77A Temp. Contact 10/2/2014 Thermometer Extech/GA10 Temp. Immersion 10/2/2014 Humidity Cooper/SRH77A Humidity 10/2/2014 Amprobe Field Piece/1201103231 Volts + Amps 10/1/2014 Thermo-Anonometer Extech/ AN100 Air Velocity 10/20/2014 Manometer Extech/ HD755 Pressure 9/30/2014 Differential Pressure Orange 0 to 100" GPM 9/30/2014 Differential Pressure Orange 0 to 100' GPM 9/30/2014 Gauges -30 to 60 PSI 9/26/2014 Gauges 0 to 100 PSI 9/26/2014 Gauges 0 to 200 PSI 9/26/2014 Magnehelic Diff. Pressure 0 to 50 -#2000 In. of H2O 10/2/2014 Tachometer Extect/1113665 RPM's 10/1/2014 Hot Wire Anemometer Alnor/9870 Air Velocity 10/20/2014 Pilot Tubes 0 to 18" & 0 to 24 Pilot Traverse NA REMARKS: NEBB TAB FIRM: HOLISTIC TEST & BALANCE TAB SUPERVISOR: LOYD E. UFFELMAN REG. NO. 2701 Page 15 LT,41110 NEBB Certification Board NEBB Certified Professional _Loyd T. ffeCman HAS MET ALL THE NEBB REQUIREMENTS FOR NEBB CERTIFIED PROFESSIONAL STATUS IN [esting, Adjusting and_Balancing of environmental Systems This Certificate,as well as individual affiliation with a NEBB Certified Firm and associated NEBB Certification stamp are REQUIRED to provide a NEBB Certified Report. Participation in the NEBB Quality Assurance Program requires that the holder of this certification also be affiliated with a NEBB Certified Firm. ►-larch 31, 2017 Expiration Date NEBB Certification Board Chairman 21703 `1,Ct,GCt; �� NEBB Certificant Number NEBB Certification Director The NEBB Certification Board retains sole ownership of all certificates.Use of this certificate is governed by the NEBB Certification Board Policy Manual. I I rill ai ` Y NEBB Certification Board NEBB Certified Technician Nicholas C. rUffe(man HAS MET ALL THE NEBB REQUIREMENTS FOR NEBB CERTIFIED TECHNICIAN STATUS IN -Cesting, Adjusting and_Balancing of&ivitori rental Systems 4 This Certificate,as well as individual affiliation with a NEBB Certified Firm and associated NEBB Certification stamp are REQUIRED to provide a NEBB Certified Report. Participation in the NEBB Quality Assurance Program requires that the holder of this certification also be affiliated with a NEBB Certified Firm. .March 31, 2017 G �4t Expiration Date NEBB Certification Board Chairman 21357 NEBB Certificant Number NEBB Certificatf.n Director The NEBB Certification Board retains sole ownership of all certificates.Use of this certificate is governed by the NEBB Certification Board Policy Manual. I • II - — y Tuff—tuition THIS IS TO CERTIFY THAT 3-Lolistic Test & Balance Inc. HAS MET ALL REQUIREMENTS FOR NEBB CERTIFICATION IN THE FOLLOWING DISCIPLINE £[eslirig Adjusting anc L a`ancing of envilionmerltal Systems FOR THE NEBB BOARD OF DIRECTORS .March 31, 2017 - Expiration Date NEBB P esident 2701 NEBB Certification Number NEBB President-Elect