Loading...
96 ARDELLA RD - ENERGY SHEETS FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: EH144715 Builder Name: Elitt Homes Street: Ardella Rd.West unit Permit Office: /t,/b. _„ 7: City,State,Zip: Atlantic Beach , FL, Permit Number: /5' OA X"' 151 3 FILE Owner: Chris Lambertson Jurisdiction: 261100 III Design Location: FL,MAYPORT_NS 1. New construction or existing New(From Plans) 9. Wall Types(1256.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=13.0 1104.00 ft' b. Frame-Wood,Adjacent R=13.0 152.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types (740.0 sqft.) Insulation Area a. Roof Deck(Unvented) R=0.0 740.00 ft 6. Conditioned floor area above grade(ft2) 1447 b. N/A R= ft2 c. R= ft2 Conditioned floor area below grade(ft') 0 11 DN R cts R ft' 7. Windows(131.0 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH: Bedroom 1 6 281.6 a. U-Factor: Dbl,U=0.37 131.00 ft' SHGC: SHGC=0.45 b. U-Factor N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit ".11 48.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems L y� kBtu/hr Efficiency d. U-Factor: N/A ft2 a- Electric Heat Pump L �' 48.0 HSPF:8.00 SHGC: C.- Area Weighted Average Overhang Depth: 3.149 ft. Area Weighted Average SHGC: 0.450 14. Hot water systems 8. Floor Types (1440.0 sqft.) Insulation Area a. Electric �` Cap:66 gallons EF:0.950 a. Floor Over Other Space R=0.0 736.00 ft2 b. Conservation features b. Slab-On-Grade Edge Insulation R=0.0 704.00 ft' None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 27.64 PASS Glass/Floor Area: 0.091 Total Standard Reference Loads: 35.93 ............... I hereby certify that the plans and spec ifications covered by Review of the plans and .•�04 ,otxE.ST9TF'.;; this calculation are in co.4p nce w the hrida Energy specifications covered by this ti.: - ; O :. 4,. Code. calculation indicates compliance ° + f co with the Florida Energy Code. m„ ,;:`O _ _ PREPARED BY: • ik Before construction is completed €---- 1°'r4 .2 r _ DATE: //t a this building will be inspected for ; O c a compliance with Section 553.908 .,.. - t I hereby certify that this building, as desi ned, is in compliance Florida Statutes. with the Florida Energy �e �/y� *•.,,COpwE/4��,.• OWNER/AGENT: � !_!` r BUILDING OFFICIAL: fill ` DATE: DATE: _ 71/S'/ r _ - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 7/14/2015 10:13 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: EH144715 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1447 Lot# Owner: Chris Lambertson Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Elite Homes Rotate Angle: 270 Street: Ardella Rd.West unit Permit Office: Cross Ventilation: County: Duval Jurisdiction: 261100111 Whole House Fan: City,State,Zip: Atlantic Beach , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT_NS FL_MAYPORT_NS 2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 Block/ 1447 11576 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Kitchen 156 1248 Yes 2 1 Yes Yes Yes 2 Dining Room 156 1248 No 2 0 1 Yes Yes Yes 3 Living Room 320 2560 No 2 0 1 Yes Yes Yes 4 Bedroom 1 199 1592 No 0 1 1 Yes Yes Yes 5 Bedroom 2 288 2304 No 0 1 1 Yes Yes Yes 6 Bedroom 3 256 2048 No 0 1 1 Yes Yes Yes 7 Stairwell 72 576 No 0 0 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Kitchen 12 ft 0 156 ft2 ____ 1 0 0 2 Slab-On-Grade Edge Insulatio Dining Room 12 ft 0 156 ft2 ____ 0 1 0 3 Slab-On-Grade Edge Insulatio Living Room 34 ft 0 320 ftz ____ 0 1 0 4 Slab-On-Grade Edge Insulatio Stairwell 3 ft 0 72 ft2 ____ 0 0 1 5 Floor Over Other Space Bedroom 1 ____ ____ 192 ft2 0 0 0 1 6 Floor Over Other Space Bedroom 2 ____ ____ 288 ft2 0 0 0 1 7 Floor Over Other Space Bedroom 3 ____ ____ 256 ft2 0 0 0 1 7/14/2015 10:13 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Y # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1567 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC 1 # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1447 ft2 N N CEILING ✓ # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Unvented) Kitchen 30 1 ft2 0.11 Wood 2 Under Attic(Unvented) Dining Room 30 1 ft2 0.11 Wood 3 Under Attic(Unvented) Living Room 30 1 ft2 0.11 Wood 4 Under Attic(Unvented) Stairwell 30 1 ft2 0.11 Wood 5 Under Attic(Unvented) Bedroom 1 30 192 ft2 0.11 Wood 6 Under Attic(Unvented) Bedroom 2 30 288 ft2 0.11 Wood 7 Under Attic(Unvented) Bedroom 3 30 256 ft2 0.11 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V # Ornt..____To.__. iNaU Type _- _S ce- R-Value _Ft In- Ft In Area R-Value Fraction Absor. Grade% 1 W=>S Garage Frame-Wood Kitchen 13 16 0 8 0 128.0 ft2 0.23 0.75 0 2 N=>W Exterior Frame-Wood Kitchen 13 12 0 8 0 96.0 ft2 0.23 0.75 0 3 N=>W Exterior Frame-Wood Dining Room 13 12 0 8 0 96.0 ft2 0.23 0.75 0 4 N=>W Exterior Frame-Wood Living Room 13 18 0 8 0 144.0 ft2 0.23 0.75 0 5 E=>N Exterior Frame-Wood Living Room 13 18 0 8 0 144.0 ft2 0.23 0.75 0 6 N=>W Garage Frame-Wood Stairwell 13 3 0 8 0 24.0 ft2 0.23 0.75 0 7 W=>S Exterior Frame-Wood Bedroom 1 13 16 0 8 0 128.0 ft2 0.23 0.75 0 8 N=>W Exterior Frame-Wood Bedroom 1 13 12 0 8 0 96.0 ft2 0.23 0.75 0 9 N=>W Exterior Frame-Wood Bedroom 2 13 18 0 8 0 144.0 ft2 0.23 0.75 0 10 N=>W Exterior Frame-Wood Bedroom 3 13 16 0 8 0 128.0 ft2 0.23 0.75 0 11 E=>N Exterior Frame-Wood Bedroom 3 13 16 0 8 0 128.0 ft2 0.23 0.75 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W=>S Wood Kitchen None .46 2 8 6 8 17.8 ft2 2 N=>W Wood Living Room None .46 3 6 8 20 ft2 7/14/2015 10:13 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 3 Vinyl Double(Tinted) Yes 0.37 0.45 15.0 ft2 1 ft 6 in 12 ft 0 in Drapes/blinds None 2 N=>W 4 Vinyl Double(Tinted) Yes 0.37 0.45 20.0 ft2 1 ft 6 in 12 ft 0 in Drapes/blinds None 3 E=>N 5 Vinyl Double(Tinted) Yes 0.37 0.45 48.0 ft2 6 ft 0 in 8 ft 0 in Drapes/blinds None 4 W=>S 7 Vinyl Double(Tinted) Yes 0.37 0.45 18.0 ft2 1 ft 6 in 5 ft 0 in Drapes/blinds None 5 N=>W 9 Vinyl Double(Tinted) Yes 0.37 0.45 15.0 ft2 1 ft 6 in 8 ft 0 in Drapes/blinds None 6 E=>N 11 Vinyl Double(Tinted) Yes 0.37 0.45 15.0 ft2 1 ft 6 in 8 ft 0 in Drapes/blinds None GARAGE # F loor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 352ft2 352 ft2 38ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgIA ACH ACH 50 1 Wholehouse Best Guess .0005 1897.8 104.18 195.93 .474 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8 48 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype _ Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 48 kBtu/hr 1440 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 66 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 281.6 ft Attic 70.4 ft2 Default Leakage Bedroom 1 (Default) (Default) 1 1 7/14/2015 10:13 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin [ Jan Feb [[ ]]Mar ]]A r Ma [X))Jun X Jul X Au ((X]Se [ ]]Oct ]Nov Dec Heating [X Jan 7(l Feb [X]Mar ' ]Ar f 1 May [ ]Jun 4 1 Jul Aug [ ]Sep [ ]Oct ;X]Nov X Dec Venting [ Jan Feb [[X]]Mar 'X]]Apr [ May [ ]]Jun [ Jul Au [[ ]Se [X]]Oct X]Nov t I Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/14/2015 10:13 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Ardella Rd. West unit PERMIT#: Atlantic Beach, FL, MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the / primary air containment passageways for air distribution systems shall // be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to = R-2 +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed&attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 r R-19 space permitting. 7/14/2015 10:13 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. Ardella Rd. West unit, Atlantic Beach, FL, 1 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame Wood, Exterior R=13.0 1104.00 ft2 b. Frame-Wood,Adjacent R=13.0 152.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck(Unvented) R=0.0 740.00 ft2 6. Conditioned floor area(ft2) 1447 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 Z a. U-Factor: Dbl. U=0.37 131.00 ft2 11. Ducts R ft a. Sup:Attic. Ret:Attic,AH: Bedroom 1 6 281.6 SHGC: SHGC=0.45 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 48.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 48.0 HSPF:8.00 Area Weighted Average Overhang Depth: 3.149 ft. Area Weighted Average SHGC: 0.450 8. Floor Types Insulation Area 14. Hot water systems a. Floor Over Other Space R=0.0 736.00 ft2 a. Electric Cap:66 gallons EF:0.95 b.Slab-On-Grade Edge Insulation R=0.0 704.00 ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building "` Construction through the above energy saving features which will be installed (or exceeded) `,oF ENE ST,�T O:••. in this home before final inspection. Otherwise, a new EPL Display Card will be completed f k�';;;''i'' ' ' based on installed Code compli nt features. '�: ,„ , „�o : �rAC�, r Builder Signature: G.,r•�'L�! - Date: 2-/,�--/1 : ca r .a Address of New City/FL Zip: 4',;.. 4%i� "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: EH144715 Builder Name: Elite Homes Street: Ardella Rd.West unit Permit Office: City,State,Zip: Atlantic Beach , FL, Permit Number: Owner: Chris Lambertson Jurisdiction: 261100 III Design Location: FL. MAYPORT_NS COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. . Breaks or joints in the air barrier are filled or repaired. i/ Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with 1 insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down I/ stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. / Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside / above-garage and cantilevered of subfloor decking. I/ 0 floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. / Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening ; / to exterior or unconditioned space are sealed. VVV Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. ii Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation �/ extends behind piping and wiring. / Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier ,/ separating them from the exterior wall. {� Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are ,/J installed. / Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to // subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2010 Florida Building Code, Energy Conservation via the residential Simulated Performance method should include ❑ Form 405(usually 5 pages/may be greater) ❑ Energy Performance Level(EPL) Display Card(one page) Required prior to CO for the Performance Method: ❑ If duct leakage has been tested then a completed Air Distribution System Test Report (usually one page) ❑ A completed Envelope Leakage Test Report(usually one page). EnergyGauge®-USRFZB v4.0 Project Summary Job: May EH147715 2 Monica Bacca 1 rY Date: May 30,2015 Nick's Solar and Air Systems Entire House By: Monica S.Bacca NICK'S SOLAR AND AIR SYSTEMS, INC. 4015 GLENVIEW RD.,JACKSONVILLE, FL Email. MONICA.BACCA @YAHOO.COM Pro-ect Information For: Chris Lambertson, Elite Homes Ardella Rd. West unit,Atlantic Beach, Fl. Notes: FILE COPY Desi• n Information Weather: Jacksonville, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 52 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 32148 Btuh Structure 30886 Btuh Ducts 8252 Btuh Ducts 8730 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 40400 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 38744 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3770 Btuh Ducts 2253 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1447 1447 Equipment latent load 6023 Btuh Volume (ft') 14470 14470 Air changes/hour 0.58 0.30 Equipment total load 44767 Btuh Equiv. AVF (cfm) 140 72 Req. total capacity at 0.70 SHR 4.6 ton Heating Equipment Summary Cooling Equipment Summary Make Ruud Make Ruud Trade RUUD UPQL SERIES Trade RUUD UPQL SERIES Model UPQL-049JEZ Cond UPQL-049JEZ AHRI ref 5646605 Coil RCFL-H*6024+RGRM-10?ZAJ? AHRI ref 5646605 Efficiency 8.5 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 32550 Btuh Heating output 44000 Btuh @ 47°F Latent cooling 13950 Btuh Temperature rise 26 °F Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Jul-14 20:49 51 +1-1- wrightsoft Right-Suite®Universal 2015 15.0.18 RSU12595 Page 1 ACCA ...ica\Documents\Wrightsoft HVAC\Demo\EH147715.rup Calc=MJ8 Front Door faces. W Manual S Compliance Report Job: May 30,15 Monica Bacca p P Date: May 30,zols Nick's Solar and Air Systems Entire House By: Monica S.Bacca NICK'S SOLAR AND AIR SYSTEMS, INC. 4015 GLENVIEW RD.,JACKSONVILLE. FL Email: MONICA.BACCA @YAHOO.COM Project Information For: Chris Lambertson, Elite Homes Ardella Rd. West unit,Atlantic Beach, Fl. Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 39615 Btuh Entering coil DB: 76.6°F Outdoor design WB: 77.3°F Latent gain: 6023 Btuh Entering coil WB: 63.4°F Indoor design DB: 75.0°F Total gain: 45639 Btuh Indoor RH: 50% Estimated airflow: 1550 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Ruud Model: UPQL-049JEZ+RCFL-H*6024+RGRM-10?ZAJ? Actual airflow: 1550 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: 31.8°F Heat loss: 40400 Btuh Entering coil DB: 69.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Ruud Model: UPQL-049JEZ+RCFL-H*6024+RGRM-10?ZAJ? Actual airflow: 1550 cfm Output capacity: 46500 Btuh 115% of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1550 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jul-14 20:49:50 wrightsoft Right-Suite®Universal 2015 15.0.18 RSU12595 Page 1 ACCP\ ...ica\Documents\Wrightsoft HVAC\Demo\EH147715.rup Calc=MJ8 Front Door faces: W Load Short Form Job: 15 May 30, Monica Bacca Date: May 30,2015 Nick's Solar and Air Systems Entire House By: Monica S.Bacca NICK'S SOLAR AND AIR SYSTEMS, INC. 4015 GLENVIEW RD.,JACKSONVILLE,FL Email: MONICA.BACCA @YAHOO.COM Project Information For: Chris Lambertson, Elite Homes Ardella Rd. West unit,Atlantic Beach, Fl. Design Information Htg Clg Infiltration Outside db (°F) 32 93 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 38 18 Fireplaces 0 Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/lb) 34 52 HEATING EQUIPMENT COOLING EQUIPMENT Make Ruud Make Ruud Trade RUUD UPQL SERIES Trade RUUD UPQL SERIES Model UPQL-049JEZ Cond UPQL-049JEZ AHRI ref 5646605 Coil RCFL-H`6024+RGRM-10?ZAJ? AHRI ref 5646605 Efficiency 8.5 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 32550 Btuh Heating output 44000 Btuh @ 47°F Latent cooling 13950 Btuh Temperature rise 26 °F Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.87 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) UPSTAIRS 743 14296 10384 548 406 FIRST FLOOR 704 26104 30897 1002 1209 Entire House 1447 40400 39615 1550 1550 Other equip loads 0 0 Equip. @ 0.98 RSM 38744 Latent cooling 6023 TOTALS 1447 40400 44767 1550 1550 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Jul-14 20:49:51 1, " wrightsoft Right-Suite®Universal 2015 15.0.18 RSU12595 Page 1 /1Cc ...ica\Documents1Wrightsoft HVAC1Demo\EH 147715.rup Calc=MJ8 Front Door faces: W �. Residential •Plans Examiner •Review Form RPER1 ACCk. for HVAC System Design (Loads. Equipment. Ducts) 15 Mar 09 Ar CollizniNCcrtazias dArrera 261100 III Header Information Contractor: NICK'S SOLAR AND AIR SYSTEMS, REQUIRED ATTACHMENTS ATTACHED INC. Manual J1 Form(and supporting worksheets): Yes 0 No ri Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes El No 0 OEM performance data(heating,cooling,blower): Yes 0 No 0 Building plan#: Manual D Friction Rate Worksheet: Yes El No 0 Duct distribution sketch: Yes E No 0 Home address(Street or Lot#,Block,Subdivision): Ardella Rd. West unit, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 32 °F Orientation: Front Door faces West °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Indoor temperature: 70 Total heat loss: 40400 Btuh Number of bedrooms: 3 Conditioned floor area: 1447 ft2 Summer Design Conditions Number of occupants: 6 Outdoor temperature: 93 °F Indoor temperature: 75 °F Windows Hoof Grains difference: 52 grub @50% RH Eave overhang depth: 0 ft Sensible heat gain: 40506 Btuh Internal shade: none Eave Latent heat gain: 6159 Btuh Blinds,drapes,etc. Depti 'Plinaov, Total heat gain: 46665 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment type. SplitASHP Equipment type: Split ASHP Heating cfm: 1550 umace,Hea pump,Boiler,etc. Air Conditioner,Heat pump,etc. Cooling cfm: 1 550 Model: Ruud Model: Ruud Static pressure: 0.60 in H2O UPQL-049JEZ Fan's rated external static pressure for UPQL-049JEZ design airflow ,, Heating output capacity: 0 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design outdoor conditions Sensible cooling capacity: 0 Btuh Aux. heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 1550 cfm Longest supply duct: 210 ft Duct Materials Used Equipment design ESP: 0.60 in H2O Longest return duct: 62 ft Trunk duct: Fiberglass board Total device pressure losses: -0.3 in H2O Total effective length(TEL): 272 ft Available static pressure(ASP): 0.25 in H2O Friction rate: �.0�Z in/100ft Branch duct: Round flex vinyl Friction Rate=ASP+IT x 1 I declare the load calculation.equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: r c r`C - ' ' CC-NC/L- b ,, Contractor's signature: ` . ,,C_ Date: Reserved for County.Town Municipality or Authority having jurisdiction use. 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist ± wrightsoft Right-Suite®Universal 2015 15.0.18 RSU12595 N c_ ()J Level 1 KITCHEN DINING ROOM GARAGE — LIVING ROOM I UTIUPO\ DER RM h I ST RS Q H2 BR2/BTH I BR1 BB 13 Job#: EH147715 NICK'S SOLAR AND AIR SYSTEMS, I... Scale: 1 : 114 Performed by Monica S. Bacca for: Page 1 Chris Lambertson 4015 GLENVIEW RD. Right-Suite®Universal 2015 Ardella Rd. West unit JACKSONVILLE, FL 2015-Jul-14 14 20:595 2015-Jul-14 20:51:16 Atlantic Beach, Fl. ...rightsoft HVAC\Demo\EH147715.rup MONICA.BACCA @YAHOO.COM Duct System Summary Job: EH147715 Monica Bacca Y Date: May 30,2015 Nick's Solar and Air Systems Entire House y' B Monica S.Bacca NICK'S SOLAR AND AIR SYSTEMS, INC. 4015 GLENVIEW RD.,JACKSONVILLE. FL Email:MONICA.BACCA @YAHOO.COM Project Information For: Chris Lambertson, Elite Homes 11 Ardella Rd. West unit,Atlantic Beach, Fl. Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.35 in H2O 0.35 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply / return available pressure 0.193/0.057 in H2O 0.193/ 0.057 in H2O Lowest friction rate 0.092 in/100ft 0.092 in/100ft Actual air flow 1550 cfm 1550 cfm Total effective length (TEL) 272 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH 2 h 2159 83 38 0.092 7.0 Ox 0 VIFx 40.0 170.0 st1 BR 1 h 4580 176 131 0.109 9.0 Ox 0 VIFx 7.0 170.0 st1 BR2/BTH 1 h 2316 89 81 0.094 7.0 Ox 0 VIFx 15.0 190.0 st1 BR2/BTH 1-A h 2072 89 81 0 0 Ox 0 VIFx 0 0 BR3 h 2924 112 74 0.094 8.0 Ox 0 VIFx 26.0 180.0 st1 DINING ROOM c 3407 93 133 0 0 Ox 0 VIFx 0 0 DINING ROOM-A C 3407 93 133 0 0 Ox 0 VIFx 0 0 KITCHEN c 3243 93 127 0 0 Ox 0 VIFx 0 0 KITCHEN-A c 3243 93 127 0 0 Ox 0 VIFx 0 0 LIVING ROOM c 3798 132 149 0 0 Ox 0 VIFx 0 0 LIVING ROOM-A c 3796 132 149 0 0 Ox 0 VIFx 0 0 LIVING ROOM-B c 3796 132 149 0 0 Ox 0 VIFx 0 0 LIVING ROOM-C c 3796 132 149 0 0 Ox 0 VIFx 0 0 STAIRS h 886 50 35 0 0 Ox 0 VIFx 0 0 UTIUPOWDER RM c 1527 50 60 0 0 Ox 0 VIFx 0 0 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 460 325 0.092 674 11.0 8 x 14 RectFbg Bold/italic values have been manually overridden wrightsoft 2015-Jul-14 20:51:53 g1 9 Right-Suite®Universal 2015 15.0.18 RSU12595 Page 1 ACCT. ...ica\Documents\Wrightsoft HVAC\Demo\EH147715.rup Calc=MJ8 Front Door faces: W Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox0 770 720 62.0 0.092 551 16.0 Ox 0 VIFx rb1 Ox 0 780 895 0 0 0 0 Ox 0 VIFx wri htsoft 2015-Jul-14 20:51:53 .►t 9 Right-Suite®Universal 2015 15.0 18 RSU12595 Page 2 ACC■ ...ica\Documents\Wrightsoft HVAC\Demo\EH147715 rup Calc=MJ8 Front Door faces: W FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: EH144715 Builder Name: Elite�Homes Street: Ardella Rd. East unit Permit Office: !, City,State,Zip: Atlantic Beach , FL, FILE COPY Permit Number: / 3 - p pL x- 15 13 Owner: Chris Lambertson Jurisdiction: 261100 III Design Location: FL, MAYPORT_NS 1. New construction or existing New(From Plans) 9. Wall Types(1256.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame Wood,Exterior R=13.0 1104.00 ft' b. Frame-Wood,Adjacent R=13.0 152.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (740.0 sqft.) Insulation Area a. Roof Deck(Unvented) R=0.0 740.00 ft2 6. Conditioned floor area above grade(ft2) 1447 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(131.0 sqft.) Description Area a. Sup:Attic, Ret:Attic,AH: Bedroom 1 6 281.6 a. U-Factor: Dbl, U=0.37 131.00 ft2 SHGC: SHGC=0.45 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 48.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 48.0 HSPF:8.00 SHGC: Area Weighted Average Overhang Depth: 3.149 ft. Area Weighted Average SHGC: 0.450 14. Hot water systems a. Electric Cap:66 gallons 8. Floor Types (1440.0 sqft.) Insulation Area EF:0.950 a. Floor Over Other Space R=0.0 736.00 ft2 b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 704.00 ft2 None c. N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 28.40 PASS Glass/Floor Area: 0.091 Total Standard Reference Loads: 35.93 I hereby certify that the plans and specifications covered by Review of the plans and ,,.0.014.E ST,gl :;,.. •this calculation are in complian - with t•e F .rids Energy specifications covered by this •• ':--' , ;..O.; Code. calculation indicates compliance Fi� ;'',,.'N.,;.... with the Florida Energy Code. r- O PREPARED BY: �� Before construction is completed �' __ w � v DATE: f this building will be inspected for :a compliance with Section 553.908 ,`•. a�a s Florida Statutes. ♦ ' ` �Y I hereby certify that this bu 'rig, as designed, is in compliance �. :.c;S.• with the Florida Energy od CO-•.. b wf. .0• OWNER/AGENT: BUILDING OFFICIAL: 77/'9 . S i/5- •. DATE: _ /IC _ DATE: / - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 7/14/2015 10:33 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: EH144715 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1447 Lot# Owner: Chris Lambertson Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Elite Homes Rotate Angle: 90 Street: Ardella Rd. East unit Permit Office: Cross Ventilation: County: Duval Jurisdiction: 261100 III Whole House Fan: City,State,Zip: Atlantic Beach , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT_NS FL_MAYPORT_NS 2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 Block1 1447 11576 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Kitchen 156 1248 Yes 2 1 Yes Yes Yes 2 Dining Room 156 1248 No 2 0 1 Yes Yes Yes 3 Living Room 320 2560 No 2 0 1 Yes Yes Yes 4 Bedroom 1 199 1592 No 0 1 1 Yes Yes Yes 5 Bedroom 2 288 2304 No 0 1 1 Yes Yes Yes 6 Bedroom 3 256 2048 No 0 1 1 Yes Yes Yes 7 Stairwell 72 576 No 0 0 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Kitchen 12 ft 0 156 ft2 ____ 1 0 0 2 Slab-On-Grade Edge Insulatio Dining Room 12 ft 0 156 ft2 ____ 0 1 0 3 Slab-On-Grade Edge Insulatio Living Room 34 ft 0 320 ft2 ____ 0 1 0 4 Slab-On-Grade Edge Insulatio Stairwell 3 ft 0 72 ft2 ____ 0 0 1 5 Floor Over Other Space Bedroom 1 ____ ____ 192 ft2 0 0 0 1 6 Floor Over Other Space Bedroom 2 ____ ____ 288 ft2 0 0 0 1 7 Floor Over Other Space Bedroom 3 ____ ____ 256 ft2 0 0 0 1 7/14/2015 10:33 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1567 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1447 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Unvented) Kitchen 30 1 ft2 0.11 Wood 2 Under Attic(Unvented) Dining Room 30 1 ft2 0.11 Wood 3 Under Attic(Unvented) Living Room 30 1 ft2 0.11 Wood 4 Under Attic(Unvented) Stairwell 30 1 ft2 0.11 Wood 5 Under Attic(Unvented) Bedroom 1 30 192 ft2 0.11 Wood 6 Under Attic(Unvented) Bedroom 2 30 288 ft2 0.11 Wood 7 Under Attic(Unvented) Bedroom 3 30 256 ft2 0.11 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V ._#.--Omt---- To-. Wall Type Spate-___R-Value .__Ft to Ft In. Area--- RVatu?- Fraction Absor. Grade% 1 W=>N Garage Frame-Wood Kitchen 13 16 0 8 0 128.0 ft2 0.23 0.75 0 2 N=>E Exterior Frame-Wood Kitchen 13 12 0 8 0 96.0 ft2 0.23 0.75 0 3 N=>E Exterior Frame-Wood Dining Room 13 12 0 8 0 96.0 ft2 0.23 0.75 0 4 N=>E Exterior Frame-Wood Living Room 13 18 0 8 0 144.0 ft2 0.23 0.75 0 5 E=>S Exterior Frame-Wood Living Room 13 18 0 8 0 144.0 ft2 0.23 0.75 0 6 N=>E Garage Frame-Wood Stairwell 13 3 0 8 0 24.0 ft2 0.23 0.75 0 7 W=>N Exterior Frame-Wood Bedroom 1 13 16 0 8 0 128.0 ft2 0.23 0.75 0 8 N=>E Exterior Frame-Wood Bedroom 1 13 12 0 8 0 96.0 ft2 0.23 0.75 0 9 N=>E Exterior Frame-Wood Bedroom 2 13 18 0 8 0 144.0 ft2 0.23 0.75 0 10 N=>E Exterior Frame-Wood Bedroom 3 13 16 0 8 0 128.0 ft2 0.23 0.75 0 11 E=>S Exterior Frame-Wood Bedroom 3 13 16 0 8 0 128.0 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W=>N Wood Kitchen None .46 2 8 6 8 17.8 ft2 2 N=>E Wood Living Room None .46 3 6 8 20 ft 7/14/2015 10:33 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 90 degrees). Wall Overhang V # OmtID Frame Panes NFRC U-Factor SHGC Area Depth Separation IM Shade Screening 1 N=>E 3 Vinyl Double(Tinted) Yes 0.37 0.45 15.0 ft2 1 ft 6 in 12 ft 0 in Drapes/blinds None 2 N=>E 4 Vinyl Double(Tinted) Yes 0.37 0.45 20.0 ft2 1 ft 6 in 12 ft 0 in Drapes/blinds None 3 E=>S 5 Vinyl Double(Tinted) Yes 0.37 0.45 48.0 ft2 6 ft 0 in 8 ft 0 in Drapes/blinds None 4 W=>N 7 Vinyl Double(Tinted) Yes 0.37 0.45 18.0 ft2 1 ft 6 in 5 ft 0 in Drapes/blinds None 5 N=>E 9 Vinyl Double(Tinted) Yes 0.37 0.45 15.0 ft2 1 ft 6 in 8 ft 0 in Drapes/blinds None 6 E=>S 11 Vinyl Double(Tinted) Yes 0.37 0.45 15.0 ft2 1 ft 6 in 8 ft 0 in Drapes/blinds None GARAGE V # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 352 ft2 352 ft2 38 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Best Guess .0005 1897.8 104.18 195.93 .474 9.8363 HEATING SYSTEM V # System Type Subtype_ Efficiency _ Capacity Block Ducts 1 Electric Heat Pump None HSPF:8 48 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 48 kBtu/hr 1440 dm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 66 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None R2 DUCTS —Supply— Return Air CFM 25 CFM25 HVAC# # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 281.6 ft Attic 70.4 ft2 Default Leakage Bedroom 1 (Default) (Default) 1 1 7/14/2015 10:33 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb ( ]Mar A r [ ]Ma [X]Jun X Jul X Au [X]Se [ ]Oct Nov Dec Heating lXI Jan [X Feb [X]Mar f t Ar [ ]May [ ]Jun 4 1 Jul 4 t Aug [ ]Sep [ ]Oct f X�Nov f X Dec Venting [ Jan [ Feb [X]Mar [X Apr [ ]May [ ]Jun [ Jul [ Au [ ]Sep [X]Oct [X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/14/2015 10:33 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Ardella Rd. East unit PERMIT#: Atlantic Beach, FL, MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. (/ Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. i- Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and / sealed in accordance with Section 503.2.7.2 of this code. 6 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical r ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. J No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. --------------- Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed& attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 7/14/2015 10:33 PM EnergyGauge®USA-FlaRes2010 Section 405 4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD I , ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home. • • Ardella Rd. East unit, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame Wood, Exterior R=13.0 1104.00 ft2 b. Frame-Wood.Adjacent R=13.0 152.00 ft2 3. Number of units. if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case' No a. Roof Deck(Unvented) R=0.0 740.00 ft2 6. Conditioned floor area(ft2) 1447 b. N/A R= ft2 7. Windows"` Description Area c. N/A R= ft2 a. U-Factor Dbl, U=0.37 131.00 ft2 11. Ducts R ft2 a. Sup:Attic, Ret:Attic,AH: Bedroom 1 6 281.6 SHGC: SHGC=0.45 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 48.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 48.0 HSPF:8.00 Area Weighted Average Overhang Depth: 3.149 ft. Area Weighted Average SHGC: 0.450 8. Floor Types Insulation Area 14. Hot water systems a. Floor Over Other Space R=0.0 736.00 ft2 a. Electric Cap:66 gallons EF:0.95 b.Slab-On-Grade Edge Insulation R=0.0 704.00 ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ''•.••""""""'•••••. Construction through the above energy saving features which will be installed (or exceeded) ,•• oF'�NE STgT�•.,. in this home before final inspection. Otherwise, a ne v EPL Display Card will be completed ;x`43 ;; ;• ': �, based on installed Code compliant features. :rr:,,,,„ .. .::..::...... :�0 Builder Signature: .I Date: ? "1,f !� :cI`: e_ :a Address of New o e: City/FL Zip: *fy `" l / - coo p *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: EH144715 Builder Name: Elite Homes Street: Ardella Rd. East unit Permit Office: City,State.Zip: Atlantic Beach , FL, Permit Number: Owner: Chris Lambertson Jurisdiction: 261100 III Design Location: FL, MAYPORT_NS COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. / Attic access (except unvented attic), knee wall door, or drop down ,\// stair is sealed. (77 Walls Corners and headers are insulated.Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. / Crawl space walls Insulation is permanently attached to walls. V/ Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. t/ Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. / Exception—fixtures in conditioned space. / Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut / to fit around wiring and plumbing, or sprayed/blown insulation ,v/ extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are . / installed. NNN Common wall Air barrier is installed in common wall between dwelling units. 7// HVAC register boots HVAC register boots that penetrate building envelope are sealed to v/ subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2010 Florida Building Code, Energy Conservation via the residential Simulated Performance method should include ❑ Form 405(usually 5 pages/may be greater) ❑ Energy Performance Level(EPL) Display Card(one page) Required prior to CO for the Performance Method: ❑ If duct leakage has been tested then a completed Air Distribution System Test Report (usually one page) ❑ A completed Envelope Leakage Test Report(usually one page). EnergyGauge®-USRFZB v4.0 Project Summary FLE COPY Job: ,15 May 30 Monica Bacca Date: May 30,2015 Nick's Solar and Air Systems Entire House By: Monica S.Bacca NICK'S SOLAR AND AIR SYSTEMS, INC. 4015 GLENVIEW RD.,JACKSONVILLE,FL Email: MONICA.BACCA©YAHOO.COM Project Information For: Chris Lambertson, Elite Homes Ardella Rd. East unit,Atlantic Beach, Fl. Notes: Desi• n Information Weather: Jacksonville, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 52 gr./lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32148 Btuh Structure 29956 Btuh Ducts 8252 Btuh Ducts 8730 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 40400 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 37834 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3770 Btuh Ducts 2253 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1447 1447 Equipment latent load 6023 Btuh Volume (ft') 14470 14470 Air changes/hour 0.58 0.30 Equipment total load 43858 Btuh Equiv.AVF (cfm) 140 72 Req. total capacity at 0.70 SHR 4.5 ton Heating Equipment Summary Cooling Equipment Summary Make Ruud Make Ruud Trade RUUD UPQL SERIES Trade RUUD UPQL SERIES Model UPQL-049JAZ Cond UPQL-049JAZ AHRI ref 5646536 Coil RCFL-H*6024+RGRM-10?ZAJ? AHRI ref 5646536 Efficiency 8.5 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 32550 Btuh Heating output 44000 Btuh @ 47°F Latent cooling 13950 Btuh Temperature rise 26 °F Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +I+ 20+I+ wri htsoft 15-Jul-14 18at28 9 Right-Suite®Universal 2015 15.0.18 RSU12595 Page 1 ACC\ ...ica\Documents\Wrightsoft HVAC1Demo1EH147715.rup Caic=MJ8 Front Door faces: E Job: EH147715 Monica Bacca Manual S Compliance Report Date: May 30,2015 Nick's Solar and Air Systems Entire House By: Monica S.Bacca NICK'S SOLAR AND AIR SYSTEMS, INC. 4015 GLENVIEW RD.,JACKSONVILLE,FL Email: MONICA.BACCA @YAHOO.COM Project Information For: Chris Lambertson, Elite Homes Ardella Rd. East unit, Atlantic Beach, Fl. Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 38685 Btuh Entering coil DB: 76.6°F Outdoor design WB: 77.3°F Latent gain: 6023 Btuh Entering coil WB: 63.4°F Indoor design DB: 75.0°F Total gain: 44709 Btuh Indoor RH: 50% Estimated airflow: 1550 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Ruud Model: UPQL-049JAZ+RCFL-H*6024+RGRM-10?ZAJ? Actual airflow: 1550 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: 31.8°F Heat loss: 40400 Btuh Entering coil DB: 69.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Ruud Model: UPQL-049JAZ+RCFL-H*6024+RGRM-10?ZAJ? Actual airflow: 1550 cfm Output capacity: 46500 Btuh 115% of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1550 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jul-14 18:51:28 Wrightsoft Right-Suite®Universal 2015 15.0.18 RSU12595 Page 1 /;1hil7il� ...ica\Documents\Wrightsoft HVAC\Demo\EH147715.rup Calc=MJ8 Front Door faces: E Load Short Form Job: May EH147715 2 Monica Bacca Date: May 30,2015 Nick's Solar and Air Systems Entire House By: Monica S.Bacca NICK'S SOLAR AND AIR SYSTEMS, INC. 4015 GLENVIEW RD..JACKSONVILLE,FL Email: MONICA.BACCA©YAHOO.COM Project Information For: Chris Lambertson, Elite Homes Ardella Rd. East unit,Atlantic Beach, Fl. Design Information Htg CIg Infiltration Outside db (°F) 32 93 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 38 18 Fireplaces 0 Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/Ib) 34 52 HEATING EQUIPMENT COOLING EQUIPMENT Make Ruud Make Ruud Trade RUUD UPQL SERIES Trade RUUD UPQL SERIES Model UPQL-049JAZ Cond UPQL-049JAZ AHRI ref 5646536 Coil RCFL-H*6024+RGRM-10?ZAJ? AHRI ref 5646536 Efficiency 8.5 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 32550 Btuh Heating output 44000 Btuh @ 47°F Latent cooling 13950 Btuh Temperature rise 26 °F Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.87 ROOM NAME Area Htg load Clg load Htg AVF CIg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) UPSTAIRS 743 14296 9951 548 399 FIRST FLOOR 704 26104 30739 1002 1232 Entire House 1447 40400 38685 1550 1550 Other equip loads 0 0 Equip. @ 0.98 RSM 37834 Latent cooling 6023 TOTALS 1447 40400 43858 1550 1550 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2015-Jul-1418:51:28 � 9 Right-Suite®Universal 2015 15.0.18 RSU12595 Page e 1 ACCA ...ica\Documents\Wrightsoft HVAC\Demo\EH147715 rup Calc=MJ8 Front Door faces: E Residential Plans Examiner Review Form RPER1 ACCk. for HVAC System Design (Loads. Equipment. Ducts) 15Mar09 ac«mtacasirbsaar.i. 261100 III Header Information Contractor: NICK'S SOLAR AND AIR SYSTEMS, REQUIRED ATTACHMENTS ATTACHED INC. Manual J1 Form(and supporting worksheets): Yes ❑ No 0 Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes El No ❑ OEM performance data(heating,cooling, blower): Yes ❑ No 0 Building plan#: Manual D Friction Rate Worksheet: Yes 0 No El Duct distribution sketch: Yes ❑ No 0 Home address(Street or Lot#, Block,Subdivision): Ardella Rd. East unit, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 32 °F Orientation: Front Door faces East Indoor temperature: 70 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 40400 Btuh Number of bedrooms: 3 Conditioned floor area: 1447 ft' Summer Design Conditions Number of occupants: 6 Outdoor temperature: 93 °F Indoor temperature: 75 °F Windows Root Grains difference: 52 gr/Ib @50% RH Eave overhang depth: 0 ft Sensible heat gain: 39556 Btuh Internal shade: none Latent heat gain: 6159 Btuh Blinds,drapes,eta Depe do. Total heat gain: 45714 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: SpIitASHP Equipment type: SpIitASHP Heating cfm: 1550 umace,Hear pump,Boiler,etc. it ond8ioner,Heat pump,etc. Cooling cfm: 1550 Model: Ruud Model: Ruud Static pressure: 60 in H2O UPQL-049JAZ UPQL-049JAZ Fan's rated external static pressure for design airflow Heating output capacity:. 0 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design outdoor conditions Sensible cooling capacity: 0 Btuh Aux. heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 1550 cfm Longest supply duct: 210 ft Duct Materials Used Equipment design ESP: 0.60 in H2O Longest return duct: 62 ft Trunk duct: Fiberglass board Total device pressure losses: -0.3 in H2O Total effective length(TEL): 272 ft Available static pressure(ASP): 0.25 in H2O Friction rate: 0.092 in/100ft Branch duct: Round flex vinyl Friction Rate=ASPr1T x1 I declare the load calculation.equipment.equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification Contractor's printed name: �' � t�to ,,- (s r , \� J C� Contractor's signature: I / , ' _ c;:_.__, Date: J / Reserved for County.Town Municipality or Authority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist ± wrightsoft Right-Suite®Universal 2015 15.0.18 RSU12595 N PC)0-f-dC6 n Level 1 --- KITCHEN DINING ROOM GARAGE — e LIVING ROOM I _., --- 6 I IUTIUPOVDER RM • I STARS © I I r H2 J BR2IBTH 1 BR 1 1 13 P`�-/ Job#: EH147715 NICK'S SOLAR AND AIR SYSTEMS, I... Scale: 1 : 114 Performed by Monica S. Bacca for: Page 1 Chris Lambertson 4015 GLENVIEW RD. Right-Suite®Universal 2015 Ardella Rd. East unit JACKSONVILLE, FL 015 J8 14 18 5 1 Atlantic Beach, Fl. 2015-Jul-14 18:52:12 rightsoft HVAC\Demo\EH147715.rup MONICA.BACCA @YAHOO.COM Monica Bacca Duct System Summary Job: EH147715 Date: May 30,2015 Nick's Solar and Air Systems Entire House By: Monica S.Bacca NICK'S SOLAR AND AIR SYSTEMS, INC. 4015 GLENVIEW RD.,JACKSONVILLE, FL Email: MONICA.BACCA @YAHOO.COM Project Information For: Chris Lambertson, Elite Homes Ardella Rd. East unit,Atlantic Beach, Fl. Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.35 in H2O 0.35 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply / return available pressure 0.193/ 0.057 in H2O 0.193/ 0.057 in H2O Lowest friction rate 0.092 in/100ft 0.092 in/100ft Actual air flow 1550 cfm 1550 cfm Total effective length(TEL) 272 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH 2 h 2159 83 39 0.092 7.0 Ox 0 VIFx 40.0 170.0 st1 BR 1 h 4580 176 110 0.109 9.0 Ox 0 VIFx 7.0 170.0 st1 BR2/BTH 1 h 4633 178 156 0.094 9.0 Ox 0 VIFx 15.0 190.0 st1 BR3 h 2924 112 93 0.094 8.0 Ox 0 VIFx 26.0 180.0 st1 DINING ROOM c 3261 93 131 0 0 Ox 0 VIFx 0 0 DINING ROOM-A c 3261 93 131 0 0 Ox 0 VIFx 0 0 KITCHEN c 3222 93 129 0 0 Ox 0 VIFx 0 0 KITCHEN-A c 3222 93 129 0 0 Ox 0 VIFx 0 0 LIVING ROOM c 3845 132 154 0 0 Ox 0 VIFx 0 0 LIVING ROOM-A C 3844 132 154 0 0 Ox 0 VIFx 0 0 LIVING ROOM-8 c 3844 132 154 0 0 Ox 0 VIFx 0 0 LIVING ROOM-C c 3844 132 154 0 0 Ox 0 VIFx 0 0 STAIRS h 880 50 35 0 0 Ox 0 VIFx 0 0 UTIUPOWDER RM c 1517 50 61 0 0 Ox 0 VIFx 0 0 Supply Trunk Detail Table Trunk I Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 548 399 0.092 691 11.8 8 x 16 RectFbg Bold/italic values have been manually overridden wrightsoft 2015-Jul-1418:52:33 1. Q Right-Suite®Universal 2015 15.0.18 RSU12595 Page 1 ACCA ...ica\Documents\Wrightsoft HVAC1Demo\EH147715.rup Calc=MJ8 Front Door faces: E Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 902 905 62.0 0.092 648 16.0 Ox 0 VIFx rb1 Ox 0 648 726 0 0 0 0 Ox 0 VIFx 0 0 2015-Jul-14 18:52:33 F wrightsoft Right-Bute®Universal 2015 15.0.18 RSU12595 Page 2 /R�++ Ik ...ica1 Documents\Wrightsott HVAC\Demo1EH147715 rup Calc=MJ8 Front Door faces: E