1698 MARITIME OAK DR - ENERGY SHEETS /69� 1larf -1,1' �.k McGowan, Job: Manual S Compliance fi� ®� Date: '7—(-7 Nearing&Air Rest of House) By:tl Conditioning�� 4r McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email'jjacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 34382 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 2791 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 37173 Btuh Indoor RH: 50% Estimated airflow: 1333 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L Actual airflow: 1333 cfm Sensible capacity: 34382 Btuh 100%of load Latent capacity: 2791 Btuh 100%of load Total capacity: 37173 Btuh 100%of load SHR: 92% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 32938 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer Carrier Model: CH14NB0420000A+FB4CNP042L Actual airflow: 1333 cfm o Capacity balance: 27 °F Output capacity: 40000 Btuh 121%of load Economic balance: -99 °F Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1333 cfm Output capacity: 9.7 kW 100%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jul-01 08:48:10 wrightsoft` Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 �'ti+� ...00 RES NC\Toll Brolhers\ot 119 AB Manual S.rup Calc=MJ8 Front Door faces: E McGowan s Job: Manual S Compliance Report Date: Heat1rng R Air By' Conditioning McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobslmcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 18930 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 1722 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 20652 Btuh Indoor RH: 50% Estimated airflow: 740 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0240000A+FB4CNP030L Actual airflow: 740 cfm Sensible capacity: 18930 Btuh 100%of load Latent capacity: 1722 Btuh 100%of load Total capacity: 20652 Btuh 100%of load SHR: 92% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 12562 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0240000A+FB4CNP030L Actual airflow: 740 cfm o Capacity balance: 19 °F Output capacity: 22200 Btuh 177%of load Economic balance: 19 °F Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 740 cfm Output capacity: 3.3 kW 89%of load Temp. rise: 17 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jul-01 08:48:10 wrightsoft Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 ACCA ...00 RES NC\Toll Brothers\Lot 119 AB Manual S.rup Calc=MJ8 Front Door faces: E FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION . Florida Department of Business and Professional-Regulation - Residential Performance Method Project Name: CATALINA 4320 Left Builder Name: Toll Brothers Street: 1698 Maritime Oak Dr(lot 119) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: /S- j k-g_-/q6( Owner: Toll Brothers Jurisdiction: 261300 FILE COPS Design Location: FL,Jacksonville I 1. New construction or existing New(From Plans) 9. Wall Types(3978.3 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 3480.80 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 497.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 . 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (3746.0 sqft.) Insulation Area . 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 3446.00 ft2 6. Conditioned floor area above grade(ft2) 4320 b.Knee Wall(Vented) R=19.0 300.00 ft2 c.N/A R= ft2 • Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 • •• 7. Windows(642.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd•Floor 6 516 1 a. U-Factor: Dbl,U=0:34 642.25 ft2 b.Sup: Attic,Ret:Attic,AH:.2nd Floor 6 350 • SHGC: SHGC=0.27 b. U-Factor. N/A IP F 12.Cooling systems kBtu/hr Efficiency a.Central Unit 42.0 SEER:14.00 SHGC: ' b.Central Unit 24.0 SEER:14.00 c. U-Factor: N/A -V SHGC: 13. Heating systems kBtu/hr Efficiency • ' d. U-Factor: N/A -t2 .a."Electric Heat Pump 42.0 HSPF:8.20 SHGC: b.Electric Heat Pump .24.0 HSPF:8.20 • Area Weighted Average Overhang Depth: 4.993 ft. Area Weighted Average SHGC: 0.270 •14.Hot water systems . a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (4320.0 sqft.) Insulation Area EF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 874.00 ft2 None c.other(see details) R= 610.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 56.50 Glass/Floor Area: 0.149 Total Standard Reference Loads: 89.06 PASS . I hereby certify that the plans and specifications covered by Review of the plans and �,�••"4K8E ST'�?�•,�. this calculation are in compliance with the Florida Energy specifications covered by this :''ti,.,.. ,tir'If,....94:-..., Code. . calculation indicates compliance r'co •o„ , • •�,I r .. . with the Florida Energy Code. r.i : ' PREPAR Y: 7 Before construction is completed ag ; DATE: -r this building will be inspected for 's a• compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. �r ' with the Florida Energy Code. g g P r .,''fCOD .e _ BUILDING OFFICIAL: 771 X DATE:ER/AGENT: y. U ^7• /-,,,_2 cy S' DATE: 5'/3//5 DATE: - Compliance requires completion of a Florida Alr Barrier and Insulation Inspection Checklist I I 1 5/13/2015 10:56 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 1 I PROJECT Title: CATALINA 4320 Left Bedrooms: 5 Address Type: Street Address • Building Type: User Conditioned Area: 4320 Lot# Owner: Toll Brothers Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: 1698 Maritime Oak Dr(I Permit Office: Atlantic Beach Cross Ventilation: No . County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) • Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V , Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE INT .2 32 93 70 75 1281 49 Medium ' • BLOCKS Number Name Area Volume . • 1 Blockl 2836 28360 • • 2 Block2 1484 13356 SPACES • Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 2836 28360 Yes 3 2 1 Yes Yes Yes 2 2nd Floor 1484 13356 No 3 3 1 Yes Yes Yes FLOORS ✓� # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood .Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 39.5 ft 0 2836 ft2 ____ 0 0 1 1i2 Floor Over Other Space 2nd Floor 874 ft2 0 0 0 1 ___ 610 ft2 19 0 0 1 3 Floor over Garage 2nd Floor ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V / # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) i /// 1 Gable or Shed Composition shingles 3854 ft2 862 ft2 Medium 0.7 N 0.9 No 0 26.6 ATTIC { V # Type Ventilation Vent Ratio(1 in). Area RBS IRCC • 1 Futl attic Vented 300 3446 ft2 N N 5/13/2015 10:56 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Ty.e • Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor • 38 1962 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 38 1484 ft2 0.11 Wood 3 Knee Wall(Vented) 2nd Floor 19 300 ft2 0.11 . Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below • • • Space R 1/aIUP Ft �n Ft In---Area R=Value__Eraction-Absor-Grade_%_ J 1 NE Exterior Frame-Wood 1st Floor 19 8 9 10 0 87.5 ft' 0 0.25 0.8 0 i 2 N Exterior Frame-Wood 1st Floor 19 40 6 12 0 486.0 ft' 0 0.25 0.8 0 • 3 NW Exterior Frame-Wood 1st Floor 19 3 6 12 0 42.0 ft' 0 0.25 0.8 0 4 W Exterior Frame-Wood 1st Floor 19 49 0 12 0 588.0 ft2 0 0.25 0.8 0 t 5 SW Exterior Frame-Wood 1st Floor 19 3 6 12 0 42.0 ft2 0 0.25 0.8 0 • + 6 S Exterior Frame-Wood 1st Floor 19 33 5 12 0 401.01t2 0 0.25 0.8 0 , 7 E Exterior Frame-Wood 1st Floor 19 20 1 10 0 200.8 ft2 0 0.25 0.8 0 • _ 8 E Garage Frame-Wood 1st Floor 13 49 9 10 0 497.5 ft2 0 0.25 0.8 0 9 NE Exterior "Frame-Wood 2nd Floor 19 8 9 9 0 78.8 ft2 • 0 0.25 0.8 .0 _ 10 N Exterior Frame-Wood 2nd Floor 19. 40 .9 .9 :0 366.8 ft2 0 0.25 0.8 0 ; _11 W Exterior Frame-Wood 2nd Floor 19 39 9 9 0 357.8 ftZ 0 0.25 0.8 0 i _12 S Exterior Frame-Wood 2nd Floor 19 46 .9 9 0 420.8 ft2 0 0.25 0.8 0 . • 13 E Exterior Frame-Wood 2nd Floor 19 40 -9 9 0 366.8 ft2 0 0.25 0.8 0 \Y 14 SE Exterior Frame-Wood 2nd Floor 19 4 9 9 .0 42.8 ft2 0 0.25 0.8 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated 1st Floor None .6 2 8 8 21.3 ft2 WINDOWS Orientation shown Is the entered,Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.34 0.27 24.0 ft2 1 ft 4 in 1 ft 0 In None Interior 5 .2 N 2 Vinyl Low-E Double Yes 0.34 0.27 20.0 ft2 1 ft 4 In 1 ft 0 in None Interior 5 3 NW 3 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft' 7 ft 4 In 1 ft 0 in None Interior 5 • 4 W 4 Vinyl Low-E Double Yes 0.34 0.27 128.0 ft2 9 ft 0 in 1 ft 0 In None Interior 5 • 5 W 4 Vinyl Low-E.Double Yes 0.34 0.27 30.0 ft2 4 ft 7 in 1 ft 0 in None Interior 5 • 6 W 4 Vinyl Low-E Double Yes 0.34 0.27 45.0 ft2 12 ft 1 In 1 ft 0 in None Interior 5 7 SW 5 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 7 ft 4 In 1 ft 0 in None Interior 5 8 S 6 • Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 In 11 ft 0 In None Interior 5 9 S 6 Vinyl Low-E Double Yes 0.34 0.27 10.4 ft2 1 ft 4 in 11 ft 0 in None Interior 5 10 E 7 Vinyl Low-E Double . Yes 0.34 0.27 15.0 ft2 1 ft 4 In 1 ft 0 in None Interior 5 11 S 6 Vinyl Low-E Double Yes 0.34 0.27 8.0 ft2 1 ft 4 in 11 ft 0 In None • Interior 5 12 N 2 Vinyl Low-E Double Yes 0.34 0.27 20.8 ft2 4 ft 4 In 1 ft 0 In None Interior 5 13 E 7 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 In 1 ft 0 In None Interior 5 ! 1• NE 9 Vinyl Low-E Double Yes 0.34 0.27 12.5 ft2 1 ft 4 In 1 ft 0 In None Interior 5 I I 5/13/2015 10:56 AM EnergyGauget USA-FlaRes201 0 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS , Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes •NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 15 S 12 Vinyl Low-E Double Yes 0.34 0.27 60.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 • 16 S 12 Vinyl Low-E Double Yes 0.34 0.27 7.1 ft2 1 ft 4 in 1 ft 0 in None Interior 5 17 ' E 13 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 18 E 13 Vinyl Low-E Double Yes 0.34 0.27 12.0 ft2 5 ft 0 in 1 ft 0 in None Interior 5 19 E 13 Vinyl Low-E Double Yes 0.34 0.27 33.3 ft2 5 ft 0 in 1 ft 0 in None Interior 5 20 N 10 Vinyl Low-E Double Yes 0.34 0.27 12.5 ft2 1 ft 4 In 1 ft 0 in None • Interior 5 21 W 11 Vinyl Low-E Double Yes 0.34 0.27 35.6 ft2 12 ft 0 in 1 ft 0 in None Interior 5 22 N 2 Vinyl Low-E Double Yes 0.34 0.27 8.0 ft2 1 ft 4 in 1 ft 0 In None Interior 5 23 SE 14 Vinyl Low-E Double Yes 0.34 0.27 12.5 ft2 1 ft 4 in 1 ft 0 in None Interior 5 24 W 4 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 1 ft 4 In 1 ft 0 In None Interior 5 .25 E 13 Vinyl Low-E Double Yes 0.34 0.27 12.5 ft2 1 R4 in '1 ft 0 in None Interior 5 • GARAGE i V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wail Insulation 1 683 ft2 73 ft2 64 ft 10 ft 1 • INFILTRATION 1 # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Best Guess .0003 3399A 186.62 350.97 .2844 4.6894 • HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts �� 1 Electric Heat Pump None HSPF:8.2 42 kBtulhr 1 sys#1 2 Electric Heat Pump None HSPF:8.2 24 kBtu/hr • 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts • (//, 1 Central Unit Split SEER: 14 42 kBtu/hr 1260 cfm 0.700000 1 sys#1 2 Central Unit None SEER:14 24 kBtu/hr 720 cfm 0.7 2 sys#2 HOT WATER SYSTEM / # System Type SubType Location EF Cap Use SetPnt Conservation �VJ 1 Natural Gas Tankless Garage 0.59 1 gal 60.9 gal 120 deg None • • • • 1 • • j . 5/13/2015 10:56 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 ■ SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF v None None ft2 DUCTS V/ ---Supply---- —Return-- • Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type ,Handler TOT OUT QN RLF Heat Cool ✓ 1 Attic 6 516 ft2 Attic 210 ft' Default Leakage 2nd Floor (Default) (Default) 1 1 2 Attic 6 350 ft2 Attic 242 ft2 Default Leakage 2nd Floor (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan - Feb l Mar [ ]Apr [ ]Ma (X].Jun [X Jul ]Au ]Se [ ]Oct ' Nov [ Dec Heating XI Jan X Feb X Mar [ ]Apr [ ]May [ ]Jun [ Jul Aug ]Sep [ ]Oct X�Nov [Xj Dec • Venting Jar, ]]]]]]Feb X Mar [X]]Apr [ ]May )Jun [ ]Jul ]Aug )Sep [X]Oct :X Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 .3 -4 -5 6 7 B 9 10 11 12 Cooling(WD) PM 80 80 78 78 78 78 78 78 78 80 8 78 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 78 i Heating(WD) PM 66 66 65 8 66 66 68 68 68 68 68 68 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 6 • • . 1 1 5/13/2015 10:56 AM EnergyGauge0 USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 1 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 1698 Maritime Oak Dr(lot 119) PERMIT#: • Atlantic Beach, FL, . • MANDATORY REQUIREMENTS SUMMARY-See Individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E.283. Windows and doors= 0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces: gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. • Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental • electric heat must prevent supplemental heat when compressor can meet'the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 . &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from ) N site-recovered energy. Off/timer switch required. Gas heaters minimum I. thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special • equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two \ or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. \ 5/13/2015 10:56 AM EnergyGaugee USA-FlaRes2010 Section 405.4.1 Compliant Software Page 8 of 8 I • ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD • 1 , ESTIMATED ENERGY PERFORMANCE INDEX* = 63 The lower the EnergyPerformance Index,the more efficient the home. • 1698 Maritime Oak Dr (lot 119), Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 3480.80 ft= b.Frame-Wood,Adjacent R=13.0 497.50 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types • Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 3446.00 ft2 6. Conditioned floor area(ft2) •4320 b.Knee Wall(Vented) R=19.0 300.00 ft2 c.N/A R= ft2 , 7. Windows'" Description Area 11.Ducts R ft2 a. U-Factor. Dbl,U=0.34 642.25 ft2 a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 516 SHGC: SHGC=0.27 b.Sup: Attic,Ret:Attic,AH:-2nd Floor 6 350 .b. U-Factor. N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: .b.Central Unit 24.0 SEER:14.00 d. U-Factor: NIA ft2 13.Heating systems kBtumr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 4.993 • b.Electric Heat Pump 24.0 HSPF:8.20 0.270 8. FloorTypes Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 a.Natural Gas EF:0.59 b.Floor Over Other Space R=0.0 874.00 ft2 b. Conservation features c.other(see details) R= 610.00 ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building -•.•••'°'��'�'" Construction through the above energy saving features which will be installed (or exceeded) `;.• ogZHESrgT�;'• • in this home before final inspection. Otherwise, a new EPL Display Card will be completed . J/ •;,, f:,` based on installed Code com•liant -atures. - . :1`'`'"', "" -iz-,,_"\, 0 t y "m" Builder Signature: '`���� Date: �/ 3/r 10 yL A-i Address of New Home: )(/ "/ (.fl /j�2Q,�,�� / City/FL Zip: z �' 3 ':,mac �e.. `• -'/5` .- N.or,- WE loc., *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For • information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software I TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CATALINA 4320 Left Builder Name: Toll Brothers Street: 1698 Maritime Oak Dr(lot 119) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 ll Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. \+ Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with • Insulation and any gaps are sealed. Attic access(except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and-framing is sealed. Rim Joists Rim joists are insulated and include an air barrier. �' Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. 1 Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. NJ . __ _ . Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. . N. - Garage separation Air sealing is provided between the garage and conditioned spaces. N.. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut . to fit around wiring and plumbing, or sprayed/blown insulation Nj extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. ElectricaVphone box on Air barrier extends behind boxes or air sealed-type boxes are V installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to \ subfloor or drywall. 4 Fireplace _ Fireplace walls include an air barrier. i EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software 1 • McGowan Project Summary Date: Heating&>Ai (Rest of House) By: -t ----... McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Notes: Catalina Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 94 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 19 °F Daily range M Relative humidity 50 % Moisture difference 47 grill) Heating Summary Sensible Cooling Equipment Load Sizing Structure 31366 Btuh Structure 25116 Btuh Ducts 4205 Btuh Ducts 4893 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 35571 Btuh Use manufacturer's data n Rate/swing multiplier 0.99 Infiltration Equipment sensible load 32581 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2777 Btuh Ducts 744 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2836 2836 Equipment latent load 3520 Btuh Volume(ft3) 31299 31299 Air changes/hour 0.25 0.13 Equipment total load 36101 Btuh Equiv.AVF(cfm) 128 69 Req.total capacity at 0.70 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB042 Cond CH14NB042 AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28700 Btuh Heating output 40000 Btuh @ 47°F Latent cooling 12300 Btuh Temperature rise 27 °F Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-May-13 08:42:42 ..`._ Wriplttsol°t' Comfort Builder by wrightsoft 15.0.06 RSU12270 Page 1 OILAA ...300 RES NC\Toll Brothers\CATALINA 4320 Left.rup Cale=MJ8 House faces: E McGowa.mp Project Summary Date: Heating airtir UP STAIRS By: "w''.w McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Notes: Catalina Desi•n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 94 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 19 °F Daily range M Relative humidity 50 % Moisture difference 47 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 14197 Btuh Structure 11887 Btuh Ducts 1882 Btuh Ducts 2253 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16079 Btuh Use manufacturer's data n Rate/swing multiplier 0.99 Infiltration Equipment sensible load 18231 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2022 Btuh Ducts 336 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1484 1484 Equipment latent load 2358 Btuh Volume(ft3) 14221 14221 Air changes/hour 0.35 0.19 Equipment total load 20589 Btuh Equiv.AVF(cfm) 84 45 Req.total capacity at 0.70 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB024 Cond CH14NB024 AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 16240 Btuh Heating output 22600 Btuh @ 47°F Latent cooling 6960 Btuh Temperature rise 27 °F Total cooling 23200 Btuh Actual air flow 773 cfm Actual air flow 773 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri ht�sofft" 2015-May-13 08:42:42 9 Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 2 ..300 RES NC\Toll Brothers\CATALINA 4320 Left.rup Calc=MJ8 House faces: E --".. t s,, N First Floor /—'-- . s\____ l 6x14 .'12x6 8• • 8• ` . `,• IT • , GREAT ROOM 6 x 14 1 MASTER BED " ;... 8 14 x 6 8" IIII! II IZ. ...7" Ret ,,, 10 x 6 Riser 6" 18" t6" 16 x 16 24 x 18 Sup t4" 4x8 8" T Li Riser 4x8 4" SVP 4" i 3"F.• N DINING " HIS WC%k 9. • t0 x 10 Riser IIIIII 16' as 111111 g„ r J 12 • ALL 11111,1 - 10x6 LAUND•., 6 4x8 clst 4" 12 x 12 12 x 6 + 9' 7" M'Ai R BATH ER 4x8 10 3'Fan 4" 10x 6 STUDY HERS 6" \ FOYER (\r------ - M 3'Fan a POW!" R GARAGE 8x4 14x14 4" 4x8 r—T, 4 14x14 WI 2• 10" 3"Fan BED 2 6x14 Y_/7 H r.1.1 8" 6 x 10 5" 1 Job #: McGowan's Heating & Air Conditioning Scale: 1 : 106 Performed for: Page 1 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.06 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2015-May-13 08:43:20 www.mcgowansac.com jjacobs @mcgowansac.com ...Brothers\CATALINA 4320 Left.rup A / N /1 2ND FL :_.) ,,_._. I be-1 s 11 14x6 12x12 8,. 10" se 1 16.• �3 1a° Ref bath 3. � iii 4 x 8 :.. Riser 18.. 4 4„ 12 16,. 12,. r� moch/uuini.,led Sup 16" Sup Riser : Riser 12'" 16" ■ BED 3 4 6x12 7„ 2-viay 12x6 r._7 ..YIlr.filt • 8x4,. 8x4.•. O 4" 4" f' 18x18 r VWBATH SINKS 9" 3"Fan am 12x 12 12" STAIRS/FOYER UP 12x6 9" J 7 •• • LOFT BED 4 1\ a■—/ 6x12 C IMMO -Y1 _ Job #: McGowan's Heating & Air Conditioning scale: : 106 Performed for: Page 2 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.06 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2015-May-13 08:43:20 www.mcgowansac.com jjacobs @mcgowansac.com ..Brothers\CATALINA 4320 Left.rup McGowan Duct System Summary Date: Ham ,g (Rest of House) By: ..... (sr McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.316/0.184 in H2O 0.316/0.184 in H2O Lowest friction rate 0.115 in/100ft 0.115 in/100ft Actual air flow 1367 cfm 1367 cfm Total effective length(TEL) 435 ft Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH 2 h 1265 49 19 0.129 5.0 Ox 0 VIFx 63.1 182.0 st7 BED 2 h 4721 181 142 0.127 8.0 Ox 0 VIFx 62.3 187.0 st7 DINING h 2306 89 58 0.148 6.0 Ox0 VIFx 42.9 170.0 st8 FOYER h 2679 103 57 0.171 6.0 Ox 0 VIFx 39.6 145.0 st3 GREAT ROOM c 4618 146 210 0.156 8.0 Ox 0 VIFx 37.2 165.0 st8 GREAT ROOM-A c 4618 146 210 0.152 8.0 Ox 0 VIFx 42.7 165.0 st8 HERS h 491 19 11 0.149 4.0 Ox 0 VIFx 45.5 167.0 st6 HIS h 537 21 6 0.146 4.0 Ox 0 VIFx 49.5 167.0 st6 LAUNDRY c 192 8 9 0.153 4.0 Ox 0 VIFx 39.1 167.0 st6 MASTER BATH h 2456 94 43 0.150 6.0 Ox 0 VIFx 43.7 167.0 st6 MASTER BED c 2397 107 109 0.115 8.0 Ox 0 VIFx 69.0 205.0 st9 MASTER BED-A c 2397 107 109 0.116 8.0 Ox 0 VIFx 68.4 205.0 st9 NOOK/KITCHEN c 2813 71 128 0.202 7.0 Ox 0 VIFx 24.5 132.0 st2 NOOK/KITCHEN-A c 2813 71 128 0.115 8.0 Ox 0 VIFx 69.7 205.0 st9 POWDER h 274 11 7 0.128 4.0 Ox 0 VIFx 65.4 182.0 st7 STUDY h 3535 136 111 0.177 7.0 Ox 0 VIFx 38.5 140.0 st3 WC c 23 0 1 0.146 4.0 Ox 0 VIFx 44.0 172.0 st6 \MC 2 h 255 10 7 0.131 4.0 Ox 0 VIFx 59.1 182.0 st7 2015-May-13 08:42:42 Atz5k-Pk wrightsoft Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 1 ...300 RES NC1Toll Brothers\CATALINA 4320 Left.nip Calc=MJ8 House faces: E Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 142 70 0.146 408 8.0 0 x 0 VinIFIx st2 st7 Peak AVF 250 175 0.127 459 10.0 0 x 0 VinlFlx st2 st9 Peak AVF 284 346 0.115 441 12.0 0 x 0 VinIFIx st8 st8 Peak AVF 665 825 0.115 591 16.0 0 x 0 VinIFIx st3 st3 Peak AVF 903 994 0.115 712 16.0 0 x 0 VinIFIx st2 Peak AVF 464 373 0.127 590 12.0 0 x 0 VinlFlx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 399 397 160.0 0.115 373 14.0 Ox 0 VIFx rt2 rb11 Ox 0 489 343 132.2 0.139 1107 9.0 Ox 0 VIFx rt2 rb10 Ox 0 479 627 0 0 0 0 Ox 0 VIFx Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt2 Peak AVF 888 740 0.115 503 18.0 0 x 0 VinIFIx 2015-May-13 08:42:42 wrightsoft', Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 2 ...300 RES NC\Toll Brothers\CATALINA 4320 Left.rup Calc=MJ8 House faces: E , McGowan Duct System Summary Date: g UP STAIRS By: " """" "r McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs©mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.308/0.192 in H2O 0.308/0.192 in H2O Lowest friction rate 0.119 in/100ft 0.119 in/100ft Actual air flow 773 cfm 773 cfm Total effective length(TEL) 420 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk BATH h 398 19 13 0.145 4.0 Ox 0 VIFx 37.0 175.0 st4 BED 3 h 1878 90 86 0.151 7.0 Ox 0 VIFx 33.6 170.0 st4 BED 4 h 2139 103 102 0.125 7.0 Ox 0 VIFx 45.1 200.0 st5 LOFT c 2232 117 122 0.126 7.0 Ox 0 VIFx 38.7 205.0 st5 LOFT-A c 2232 117 122 0.119 7.0 Ox 0 VIFx 48.3 210.0 st5 LOFT-B c 2232 117 122 0.145 7.0 Ox 0 VIFx 36.4 175.0 st4 SINKS c 72 2 4 0.149 4.0 Ox 0 VIFx 32.0 175.0 st4 bath 3 h 309 15 10 0.192 4.0 Ox 0 VIFx 24.9 135.0 st1 bed 5 c 3394 183 186 0.197 8.0 Ox 0 VIFx 21.4 135.0 st1 sinks 3 h 193 9 6 0.198 4.0 Ox 0 VIFx 20.3 135.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 773 773 0.119 554 16.0 0 x 0 VinIFIx st5 Peak AVF 337 346 0.119 441 12.0 0 x 0 VinIFIx st4 st4 Peak AVF 566 571 0.119 534 14.0 0 x 0 VinIFIx st1 2015-May-13 08:42:42 �jtwrightsoft Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 3 /QUI% ...300 RES NC\Toll Brothers\CATALINA 4320 Lefl.rup Calc=MJ8 House faces: E Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb7 Ox 0 207 202 160.6 0.120 380 10.0 Ox 0 VIFx rt1 rb6 Ox 0 220 224 145.0 0.133 507 9.0 Ox 0 VIFx rtl rb3 Ox 0 112 103 146.0 0.132 253 9.0 Ox 0 VIFx ill rb4 Ox 0 234 244 161.6 0.119 552 9.0 Ox 0 VIFx 111 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rtl Peak AVF 773 773 0.119 554 16.0 0 x 0 VinIFIx wrf htSaft° 2015-May-13 08:42:42 AWA g Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 4 ..300 RES NCIToII Brothers\CATALINA 4320 Left.rup Calc=MJ8 House faces: E