Loading...
616 TIMBER BRIDGE LN - ENERGY SHEETS . _•_..,__• _ ___ ___ • FILE COPY i FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CATALINA 4372 Right Builder Name: Toll Brothers Street: 616 Timber Bridge Lane(lot 167) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number:/5=SP/'-/3-3-q-5- Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(4093.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3595.60 ft2 b.Frame-Wood,Adjacent R=13.0 497.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (3561.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 3431.00 ft2 6. Conditioned floor area above grade(ft2) 4372 b.Knee Wall(Vented) R=19.0 130.00 ft2 • c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(622.8 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 516 a. U-Factor: Dbi,U=0.33 622.78 ft2 • b.Sup: Attic,Ret:Attic,AN:Attic 6 350 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 42.0 SEER:14.00 SHGC: b.Central Unit 24.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: b.Electric Heat Pump 24.0 HSPF:8.20 Area Weighted Average Overhang Depth: 4.516 ft. Area Weighted Average SHGC: 0.240 14.Hot water systems • a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (4372.0 sqft.) Insulation Area EF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 2823.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 941.00 ft2 None • . ot�1'P1-60oiEITMo-difiieti''L- -ds-'52 38 AS S4". ..•,- Glass/Floor Area:. 0.142 Total Standard Reference Loads: 83.18 Review of the plans and 0.0"1,0057:13:,4., I hereby certify that the plans and specifications covered by , O ; ......... ..._ h` ku this calculation are in compliance with the Florida Energy . specifications covered by this ` 1':� ..-.. ;..•..0�,' Code. calculation indicates compliance 'cy %i„ . ;*� r ��.'� with the Florida Energy Code. c rrre r .1•.,• a`..O - PREPARED Y: --- - f� ,) j'' . ht/ . Before construction is completed a ;'6 .-4 I: �� �' �� s DATE: r this building will be inspected for c,0 4 '.r- ;�' compliance with Section 553.908 *`.• . '* . I hereby certify that this building,as designed,is in compliance Florida Statutes. 'r,_�rr;C.., ......:A c. with the Florida Energy Code. //�/��,J1r,/ ��" Ob . 's, ••OWNER/AGENT: BUILDING OFFICIAL: DATE: /9 ,slf DATE: 1 Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 6/2/2015 10:17 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 1 I i PROJECT i Title: CATALINA 4372 Right Bedrooms: 5 Address Type: Street Address • Building Type: User Conditioned Area: 4372 Lot# Owner: Toll Brothers Total Stories: 2 Block/SubDivision: #of Units: 1 • Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: 616 Timber Bridge Lane Permit Office: Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No • City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: • CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 2823 28230 2 Block2 1549 13941 SPACES Number Name Area Volume Kitchen Occupants Bedrooms 'ail ID Finished Cooled Heated 1 1st Floor 2823 28230 Yes 3 2 1 Yes Yes Yes 2 2nd Floor 1549 13941 No 3 3 1 Yes Yes Yes FLOORS FloorT.v .�.�,�--°z Pit -° ----•- S R3o . Perme—e Ped m eter.R.V31 [e�u Jois�.R-Va14E�;;a . Tile .Wood,.;C atP.e t: i :r..n7 i 1 Slab-On-Grade Edge Insulatlo -1st Floor 390.5 ft - 0 '2823 ft' _ _ 0 0 1 -i ■ __ .�_ —_.._.. . 2 Floor Over Other Space 2nd Floor ___ ____ 941 ft' 0 0 0 1 3 Floor over Garage 2nd Floor ___ ____ 608 ft' 19 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested insul. (deg) 1 Gable or Shed Composition shingles 3837 ft' 860 ft' Medium 0.7 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 3431 ft' N N 6/2/2015 10:17 AM EnergyGauge®USA-FlaRes2010 Section 405.4,1 Compliant Software Page 2 of 6 CEILING c V # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 38 1882 ft2 0.11 . Wood 2 Under Attic(Vented) 2nd Floor •38 1549 ft2 0.11 Wood 3 Knee Wall(Vented) 1st Floor 19 130 ft2 0.11 Wood • WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below i V # Ornt TO Wall Type p R-Value Ft In Ft in Area -R-\fatue Fraction-Absor.--Grade9L. 1 NE Exterior Frame-Wood 1st Floor 19 8 9 10 0 87.5 ft2 0 0.25 0.8 • 0 _ 2 E Exterior Frame-Wood 1st Floor 19 40 6 12 0 486.0 ft2 0 0.25 0.8 0 3 SW Exterior Frame-Wood 1st Floor. 19 3 6 12 0 42.0 ft2 • 0 0.25 0.8 . 0 • 4 S Exterior Frame-Wood 1st Floor 19 49 0 12 0 588.0 ft2 0 0.25 0.8 0 _ 5 SE Exterior Frame-Wood 1st Floor 19 3 6 12 0 42.0 ft2 0 0.25 0.8 0 6 W Exterior Frame-Wood 1st Floor 19 33 5 12 0 401.0 ft2 0 • 0.25 • 0.8 0 _ 7 N Exterior Frame-Wood 1st Floor 19 20 1 10 0 200.8 ft2 0 0.25 0.8 0 B N Garage Frame-Wood 1st Floor 13 49 9 10 0 497.5 ft2 0 0.25 0.8 0 9 NE Exterior Frame-Wood 2nd Floor 19 8 9 9 0 78.8 ft2 0 0.25 0.8 0 _10 E Exterior Frame-Wood 2nd Floor 19 40 9 9 0 366.8 ft2 0 0.25 0.8 0 11 S Exterior Frame-Wood 2nd Floor 19 39 9 9 0 357.8 ft2 0 0.25 0.8 0 _12 W Exterior Frame-Wood 2nd Floor 19 46 9 9 0 420.8 ft2 0 0.25 0.8 0 _13 N Exterior Frame-Wood 2nd Floor 19 40 9 9 0 366.8 ft2 0 0.25 0.8 0 ■ _14 SE Exterior Frame-Wood 2nd Floor 19 8 9 9 0 78.8 ft2 0 0.25 0.8 0 15 NW Exterior Frame-Wood 2nd Floor 19 8 9 9 0 78.8 ft2 0 0.25 0.8 0 i DOORS • ✓ # Ornt Door Type Space Storms U-Value Ft Width In Ft Heightln Area °M ="'1I■1 EM?Irisulatedt7F16o`r" - None tS .rrlatArt .B1ct•Fkmr--- '-241t2I -hie 1-- . 4 „2:___,,,____N_-_„_,_ .Insulated..._._....,:_.jst.Floor___.. y _._None i6 .2.. .:...8___- 8•--•• --- _,_.21t-ft° WINDOWS Orientation shown is the entered,Proposed orientation. • i / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Double Yes 0.33 0.24 20.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 2 E 2 Vinyl Low-E Double Yes 0.33 0.24 30.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 3 SW 3 Vinyl Low-E Double Yes 0.33 0.24 15.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 4 S 4 Vinyl Low-E Double Yes 0.33 0.24 128.0 ft2 9 ft 0 in 1 ft 0 in None Interior 5 5 • S 4 Vinyl Low-E Double Yes 0.33 0.24 30.0 ft2 4 ft 4 in 1 ft 0 in None Interior 5 6 S 4 Vinyl Low-E Double Yes 0.33 0.24 45.0 ft2 12 ft 0 in 1 ft 0 in . None Interior 5 7 SE 5 Vinyl Low-E Double Yes 0.33 0.24 15.0 ft2 6 ft 4 in 1 ft 0 in None Interior 5 8 W 6 Vinyl Low-E Double Yes 0.33 0.24 30.0 ft2 1 ft 4-in 11 ft 0 in •None .. Interior 5 9 W 6 Vinyl Low-E Double Yes 0.33 0.24 10.0 ft? 1 ft 4 in 11 ft 0 in None Interior 5 10 N 7 Vinyl Low-E Double Yes 0.33 0.24 33.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 11 N 7 Vinyl Low-E Double Yes 0.33 0.24 30.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 12 NE 9 Vinyl Low-E Double Yes 0.33 0.24 16.7 ft2 1 ft 4 in 1 ft 0 in None Interior 5 I■ 6/2/2015 10:17 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 1 I WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes .NFRC U-Factor SHGC Area Depth •Separation Int Shade Screening 13 W 12 Vinyl Low-E Double Yes 0.33 0.24 60.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 14 W 12 Vinyl Low-E Double Yes 0.33 0.24 7.1 ft' 1 ft 4 in 1 ft 0 in None Interior 5 • 15 N 13 Vinyl Low-E Double Yes 0.33 0.24 • 16.7 ft2 1 ft 4 in 1 ft 0 in None Interior 5 16 N 13 Vinyl Low-E Double Yes 0.33 0.24 15.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 17 E 10 Vinyl Low-E Double Yes 0.33 0,24 12.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 i 18' S 4 Vinyl Low-E Double Yes 0.33 0.24 15.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 19 N 13 Vinyl Low-E Double Yes 0.33 0.24 33.3 ft' 8 ft 0 in 1 ft 0 in None Interior 5 20 E 2 Vinyl Low-E Double Yes 0.33 0.24 8.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 21 W 6 Vinyl Low-E Double Yes 0.33 0.24 8.0 ft2 1 ft 4 in 11 ft 0 in None Interior 5 22 N 13 Vinyl Low-E Double Yes 0.33 0.24 20.0 ft2 8 ft 0 in 1 ft 0 in None Interior 5 23 NE 9 Vinyl Low-E Double Yes 0.33 0.24 16.7 ft' 1 ft 4 in 1 ft 0 in None Interior 5 24 NW 15 Vinyl Low-E Double Yes 0.33 0.24 8.3 ft' 1 ft 4 in 1 ft 0 in None Interior 5 GARAGE ✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 692 ft' 84 ft' 64 ft 10 ft 1 • INFILTRATION • # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Best Guess .0003 3440.3 188.87 355.2 .2844 4.8949 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts I 1" ; --+ = 1 :Electric1HeatiPump :None:Osal . ..___ _ -1-1SPF:18 *Btuihr Nnnea-1-----sys#1-!--4S5 .{,_ _.,_2__.,.Electric.Fieat Bump..--None_-..,....-_ i _.HSP_F_:,8-2.:......_ :24:kBtu/hr .y- 2 .sys#2_ COOLING SYSTEM• # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:14 42 kBtu/hr 1260.cfm 0.700000 1 sys#1 2 Central Unit Split SEER:14 .24 kBtu/hr 720 cfm 0.7 2 sys#2 • HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankiess Garage 0.59 9 gal 60.9 gal 120 deg None • • I 1 ■ 6/2/2015 10:17 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 1 SOLAR HOT WATER SYSTEM FSEC Collector Storage . Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ---Supply---- ---Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 516 ft2 Attic 210 ft2 • Default Leakage Attic (Default) (Default) 1 1 2 Attic 6 350 ft2 Attic 242 ft2 Default Leakage Attic (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X 1 Jun X Jul X Au X Se Oct Nov Dec Heating EX Jan H Feb [Xi Mar f Apr f i May Jun Jul 4 Aug f Sep f Oct X�Nov f X Dec Venting [[ Jan Feb X Mar X Apr [ May Jun Jul [ Aug [ Sep X Oct X Nov t Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 _ 78 78 78 78 78 78 78 . 78 78 78. 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66. 66 66 68 68 68 68 68 68 68 PM 68 • 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 � { -1. l.3*.::.:._..._ — ":71-. . -...__ ,_.. - .. • • • • • • • . • , ! I Ji 6/2/2015 10:17 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 I FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations • Residential Whole Building Performance Method ADDRESS: 616 Timber Bridge Lane (lot 167) PERMIT#: Atlantic Beach, FL, MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENTS) CHECK Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors=0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces: gasketed doors &outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental \� electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the • • primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. �J ! 403.3.3 Building framing cavities shall not be used as supply ducts. • Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.32. Provide switch or clearly marked circuit breaker _ ._ I; "(electric)or shutoff(gas). Circulating system pipes insulated to=RR2' ---� --- -_— +-accessible-manual•O.FF=switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical • ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. '• No make-up air from attics, crawispaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or �� I other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum 1. thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. • Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two NJ or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. • 6/2/2015 10:17 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORii LANCE LEVEL (EPL) DISPLAY CARD , ESTIMATED ENERGY PERFORMANCE INDEX* = 63 The lower the EnergyPerformance Index, the more efficient the home. • ■ , 616 Timber Bridge Lane (lot 167), Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3595.60 ft2 b.Frame-Wood,Adjacent R=13.0 497.50 ft' 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 I 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=38.0 3431.00 ft2 6. Conditioned floor area(ft2) 4372 b.Knee Wall(Vented) R=19.0 130.00 ft2 7. Windows"" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.33 622.78 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic . 6 516 SHGC: SHGC=0.24 b.Sup: Attic,Ret:Attic,AH:Attic 6 350 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: b.Central Unit 24.0 SEER:14.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 •Area Weighted Average Overhang Depth: 4.516 ft. b.Electric Heat Pump 24.0 HSPF:8.20 Area Weighted Average SHGC: 0.240 8. Floor Types Insulation Area 14.Hot water systems ft2 a.Natural Gas Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2823.00 ft EF:0.59 b. Floor Over Other Space R=0.0 941.00 ft2 b. Conservation features c.other(see details) R= 608.00 ft2 None -� .. ..< ,.e - .. '.,�. , .... , - - 4_-15.Credits Pstat IrN.r:ni,� certify that this home has complied with the Florida Energy Efficiency Code for Building .00, , Construction through the above energy saving features which will be installed (or exceeded) p...��1XEST,q��oy,, in this home before final inspection. Otherwise, a new EPL Display Card will be completed ik,"..'''„t..1. ��':.'42, based on installed Code compliant features. p y p �,U,�` .v-i�..ss° ', � s W Builder Signature: Date: ......._..v,_. ,a i a 3 .� *'• bra Address of New Home: 611,/T 6cr a,,dy_ �L City/FL Zip: 3a.-.�3 '4.4••• �''.-'.4s �7I ��,L 44LL N.,.4 ••••• • *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support ' • • staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software • TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CATALINA 4372 Right Builder Name: Toll Brothers Street: 616 Timber Bridge Lane(lot 167) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access(except unvented attic), knee wall door,•or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. \. ' . i Rim joists Rim joists are insulated and include an air barrier. N Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. N floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. 7 .. "'. 7w 1: ... -.:...:Exposed tearth in.unvented-crawl}spaces-iszovered-with,Clasisdloosea-ea>1 mew arrawt vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. . Garage separation Air sealing is provided between the garage and conditioned spaces. N, Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. • Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation • extends behind piping and wiring. . Shower/tub on exterior wall Showers and tubs.on exterior walls have insulation and an air barrier,. • . separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type.boxes are. installed. N.. Common wall Air barrier is installed in common wall between dwelling units. N. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software • McGowan's, Project Summary Job: Heairng A.Air Date: Conditioning "..�� (Rest of House) By: ,.. 1 McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278.0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.corn Web:www.mcgowansac.corn Pro"ect Information For: Toll Brothers Fl .a Notes: Catalina Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32514 Btuh Structure 22626 Btuh Ducts 4284 Btuh Ducts 5393 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower Piping 0 Btuh 0 Btuh Equipment load 36798 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 30196 Btuh Method Simplified Latent Cooling E Construction quality Average g quipment Load Sizing Fireplaces 0 Structure 3564 Btuh Ducts 942 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2823 2823 Equipment latent load 6006 Btuh Volume(ft3) 32090 32090 Air changes/hour 0.25 0.13 Equipment total load 36202 Btuh Equiv. AVF(cfm) 134 72 Req. total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB042 Cond CH14NB042 AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28700 Btuh Heating output 40000 Btuh @ 47°F Latent cooling 12300 Btuh 4-' Temperature rise 27 °F Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Comfort Builder by Wrightsoft 15.0.17 RSU12270 2015-Jun-26 10:50:01 ..oil Brothers\CATALINA 4372 Right Lot 167 AB.rup Calc=MJ8 Front Door faces:NE Page 1 • McGowan Project Summary Job: ""''""'h air yyy ld UP STAIRS Byte: Conditioning' �� By: I McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:pacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Notes: Catalina Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 16632 Btuh Structure 15163 Btuh Ducts 1935 Btuh Ducts 2509 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower Piping 0 Btuh 0 Btuh Equipment load 18567 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 18414 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2476 Btuh Ducts 432 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1549 1549 Equipment latent load 2908 Btuh Volume(ft3) 14777 14777 Air changes/hour 0.34 0.18 Equipment total load 21322 Btuh Equiv.AVF (cfm) 85 45 Req. total capacity at 0.70 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB024 Cond CH14NB024 AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 16240 Btuh Heating output 22600 Btuh @ 47°F Latent cooling 6960 Btuh f Temperature rise 27 °F Total cooling 23200 Btuh Actual air flow 773 cfm Actual air flow 773 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4i÷ wrightsoft- Comfort Builder by Wrightsoft 15.0.17 RSU12270 2015-Jun-26 10:50:01 1 Page 2 'e ...oll Brothers\CATALINA 4372 Right Lot 167 AB.rup Calc=MJ8 Front Door faces:NE i1 / ■ First Floor r I 12x3 i 6x12 " • GREAT RO M NOOK/KITCHEN i 12" 14x6 14x6 12x6 6x12 h/iAS1IIRELi) 9 8.. 7" 7.. Sup Riser „, — — 12" 12x6", : • �y Ret ` Ri IL 18" 16 x 16 16' 14., Sup Ri--r 9 16 OINK' 7\1 10x10 ��3 n 9" WC HIS EF--,E 8 x 4 8 x 4 HALL 10 x 10 t---- Ail ra LOSET 4x'8 4 ' 12X6 12x12 7.. 7 9" "' �� _ CASTER BATH 10x6 6" 6x10 STUDY 10x6 6" 6 4x8HERS NW EN 4' 11 / 3"Fan FOYER 4 x 8 4" 1114 3" an 12 x 12 !O D _ GARAGE Pig �__ 12x12rx F 10" 2 .4 4x8 4„ BED 2 6 x7 2 3"Fan AM AM ■.ATH 2 6x 10 5" Job #: McGowan's Heating & Air Conditioning, Scale: 1 : 108 Performed for: Toll Brothers 4850 Collins Road Page 1 Comfort Builder by Wrightsoft Fl Orange Park,Fl 32073 15.0.17 RSU12270 Phone:904.278-0339 Fax:904-278-0366 2015-Jun-2610:50:21 ■ ww.mcgowansac.com jjacobs @mcgowansac.com TALINA 4372 Right Lot 167 AB.rup 2ND FL BEDROOM 5 14x14 14x6 12" 0" Sup Riser r Ret 72 18" 4. Sup Riserr • �IN4S ;T'H 4 76. ta E 4..,.. am 3'Fan ° STORAGE 12 91. 6x12 ! BLD3 6 x 12 1 7" 2-way 18x18 8x4 4 x 8 �d 4.. to SIN S =BATH 3 \J 3"Fan STAIRS/FOYER UP 6x10 �J LOFT 6" 12 x 12 12x6 7" _ BED 4 1 6x10 6.. Job#: McGowan's Heating & Air Conditioning, scale: : X08 Performed for: Page 2 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft F1 Orange Park,Fl 32073 15.0.17 RSU12270 Phone:904-278-0339 Fax:904-278-0366 2015-Jun-26 10:50:22 www.mcgowansac.com jjacobs @mcgowansac.com . TALINA 4372 Right Lot 167 AB rup • McGowan's. Duct System Summary NeaGnggir Date: Conditioning f (Rest of House) By: McGowan's Heating & Air Conditioning, Inc. Job: 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:pacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.279/0.111 in H2O 0.279/0.111 in H2O Lowest friction rate 0.090 in/100ft 0.090 in/100ft Actual air flow 1367 cfm 1367 cfm Total effective length(TEL) 433 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH 2 h 1586 59 36 0.095 5.0 Ox 0 VIFx 72.0 220.0 st7 BED 2 h 4540 169 118 0.096 7.0 Ox 0 VIFx 69.5 220.0 st7 DINING c 2338 82 114 0.140 7.0 Ox 0 VIFx 29.5 170.0 st5 FOYER h 2352 87 65 0.127 6.0 Ox 0 VIFx 45.0 175.0 st5 GREAT ROOM h 4067 151 150 0.135 8.0 Ox 0 VIFx 31.4 175.0 st5 GREAT ROOM-A h 4067 151 150 0.135 8.0 Ox 0 VIFx 31.9 175.0 st5 HALL-A c 1034 39 50 0.114 6.0 Ox 0 VIFx 43.6 200.0 st8 HERS h 434 16 13 0.111 4.0 Ox 0 VIFx 45.2 205.0 st8 HIS h 532 20 8 0.090 4.0 Ox 0 VIFx 64.1 245.0 st9 LAUNDRY c 6 0 0 0.120 4.0 Ox 0 VIFx 38.1 195.0 st8 MASTER BATH c 1929 88 94 0.094 6.0 Ox 0 VIFx 52.1 245.0 st9 MASTER BED c 2325 108 113 0.096 7.0 Ox 0 VIFx 68.9 220.0 st6 MASTER BED-A c 2325 108 113 0.098 7.0 Ox 0 VIFx 65.1 220.0 st6 NOOK/KITCHEN c 2086 70 102 0.095 7.0 Ox 0 VIFx 73.3 220.0 st6 NOOK/KITCHEN-A c 2086 70 102 0.097 7.0 Ox 0 VIFx 68.6 220.0 st6 POWDER c 194 9 9 0.094 4.0 Ox 0 VIFx 72.5 225.0 st7 STUDY h 3483 129 117 0.129 7.0 Ox 0 VIFx 40.6 175.0 st5 WC c 1 0 0 0.094 4.0 Ox 0 VIFx 55.6 240.0 st9 WC 2 c 212 10 10 0.097 4.0 Ox 0 VIFx 67.1 220.0 st7 c wri ht50ft" 2015-Jun-2610:50:01 9 Comfort Builder by Wnghtsoft 15.0.17 RSU12270 Page 1 /4% ...oll Brothers\CATALINA 4372 Right Lot 167 AB.rup Calc=MJ8 Front Door faces:NE • Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st7 Peak AVF 247 173 0.094 560 9.0 0 x 0 ViniFlx st3 st8 Peak AVF 163 166 0.090 376 9.0 0 x 0 VinIFIx st3 st2 Peak AVF 957 1028 0.095 736 16.0 0 x 0 VinIFIx st3 Peak AVF 410 339 0.090 522 12.0 0 x 0 VinIFIx st9 Peak AVF 108 103 0.090 404 7.0 0 x 0 VinIFIx st8 st6 Peak AVF 356 430 0.095 548 12.0 0 x 0 VinIFIx st5 st5 Peak AVF 957 1028 0.095 736 16.0 0 x 0 VinIFIx st2 Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 355 276 117.0 0.095 332 14.0 Ox 0 VIFx rt2 rb11 Ox 0 250 242 91.5 0.122 567 9.0 Ox 0 VIFx rt2 rb10 Ox 0 761 849 123.5 0.090 539 17.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt2 Peak AVF 1367 1367 0.090 774 18.0 0 x 0 VinIFIx 2015-Jun-26 10:50:01 ��.• wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 ACL A . oll Brothers\CATALINA 4372 Right Lot 167 AB.rup Calc=MJ8 Front Door faces:NE f McGowan' Duct System Summary Job: l fa6nq t'Air _�j Date: Conditioning UP STAIRS By, McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:vnwv.mcgowansac.corn Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.304/0.196 in H2O 0.304/0.196 in H2O Lowest friction rate 0.140 in/100ft 0.140 in/100ft Actual air flow 773 cfm 773 cfm Total effective length (TEL) 358 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH 3 c 388 15 17 0.150 4.0 Ox 0 VIFx 42.6 160.0 st4 BATH 4 C 383 15 17 0.188 4.0 Ox 0 VIFx 31.7 130.0 st1 BED 3 c 2900 76 127 0.193 7.0 Ox 0 VIFx 27.2 130.0 st1 BED 4 c 2321 89 102 0.149 7.0 Ox 0 VIFx 43.3 160.0 st4 BEDROOM 5-A h 6633 276 270 0.186 9.0 Ox 0 VIFx 33.0 130.0 st1 LOFT h 2312 96 76 0.152 6.0 Ox 0 VIFx 39.3 160.0 st4 LOFT-A h 2312 96 76 0.140 6.0 Ox 0 VIFx 52.2 165.0 st4 LOFT-B h 2312 96 76 0.179 7.0 Ox 0 VIFx 39.2 130.0 st1 SINKS c 71 2 3 0.152 4.0 Ox 0 VIFx 40.1 160.0 st4 SINKS 4 h 253 11 9 0.195 4.0 Ox 0 VIFx 25.8 130.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 299 274 0.140 380 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 773 773 0.140 723 14.0 0 x 0 VinlFlx t W1'I FItSOft 2015-Jun-2610:50:01 9 Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 3 ..oll Brothers\CATALINA 4372 Right Lot 167 AB.rup Calc=MJ8 Front Door faces:NE • Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb4 Ox 0 185 178 140.4 0.140 420 9.0 Ox 0 VIFx rt3 rb3 Ox 0 122 102 116.9 0.168 276 9.0 Ox 0 VIFx rt1 rb7 Ox 0 449 473 108.0 0.182 602 12.0 Ox 0 VIFx rt1 rb6 Ox 0 17 20 109.0 0.180 230 4.0 Ox 0 VIFx rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt3 Peak AVF 202 198 0.140 189 14.0 0 x 0 VinIFIx rt1 rt1 Peak AVF 773 773 0.140 554 16.0 0 x 0 VinIFIx wrightsoft 2015-Jun-2610:50:01 ,.� g Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 4 ACCA ...oil Brothers\CATALINA 4372 Right Lot 167 AB.rup Calc=MJ8 Front Door faces:NE McGowan'*. Manual S Compliance Report Job: HeatingRAir (Rest of House) Date: Conditioning „�.! OUSa By: �,-�- -rue McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax'904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 34382 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 2791 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 37173 Btuh Indoor RH: 50% Estimated airflow: 1333 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L Actual airflow: 1333 cfm Sensible capacity: 34382 Btuh 100%of load Latent capacity: 2791 Btuh 100%of load Total capacity: 37173 Btuh 100% of load SHR: 92% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 32938 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L Actual airflow: 1333 cfm Output capacity: 40000 Btuh 121%of load Capacity balance: 27 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1333 cfm Output capacity: 9.7 kW 100%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. W rl htsoft' 2015-Jun-26 10:56:26 ACCK 9 Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 ..S NC1Toll Brothers13.5 TON-2 TON Manual Snip Calc=MJ8 Front Door faces:NE McGowan' Manual S Compliance Report Job: Hcatrrrg&Air y Date: Conditioning_ �' V P By: McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobscmcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 18930 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 1722 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 20652 Btuh Indoor RH: 50% Estimated airflow: 740 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0240000A+FB4CNP030L Actual airflow: 740 cfm Sensible capacity: 18930 Btuh 100% of load Latent capacity: 1722 Btuh 100% of load Total capacity: 20652 Btuh 100% of load SHR: 92% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 12562 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0240000A+FB4CNP030L Actual airflow: 740 cfm Output capacity: 22200 Btuh 177%of load Capacity balance: 19 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 740 cfm Output capacity: 3.3 kW 89%of load Temp. rise: 17 °F The above equipment was selected in accordance with ACCA Manual S. W rl htsoft' 2015-Jun-26 10:56:26 9 Comfort Builder by Wr ghtsofl 15.0.17 RSU12270 Page 2 ACCK ..S NC\Toll Brothers\3.5 TON•2 TON Manual S.rup Calc=MJ8 Front Door faces:NE