Loading...
1705 MARITIME OAK DR - ENERGY SHEETS FORM 405-10 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION IFlorida Department of Business and Professional Regulation - Residential Performance Method • I Project Name: Anastasia Bonus 3621 Left Builder Name: Toll Brithers Inc. I Street: 1705 Maritime Oak Dr Permit Office: St.Johns City,State,Zip: Atlantic Beach,FL, - Permit Number: Owner: Toll Architecture Jurisdiction: 651000 Design Location: FL,St.Augustine I I . 1. New construction or existing New(From Plans) 9. Wall Types(2915.3 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 2663.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 252.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 . 10.Ceiling Types (2991.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2866.00 ft2 2 b.Knee Wall(Vented) R=19.0 125.00 ft2 6. Conditioned floor area above grade(ft2) 3621 - N c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 ` 7. Windows(410.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 253 a. U-Factor: -Dbl,U=0.34 410.00 ft2 .b.Sup: Attic,Ret:Attic,AH:Attic 6 200 SHGC: SHGC=0.27 • b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 18.0 SEER:14.00 SHGC: • b.Central Unit 36.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 1 13.Heating systems kBtu/hr Efficiency• d. U-Factor: 'N/A ft2 a.Electric Heat Pump 18.0 HSPF:8.00 SHGC: .b.Electric Heat Pump 36.0 HSPF:8.00 j Area Weighted Average Overhang Depth: 6.774 ft. Area Weighted Average SHGC: 0.270 14.Hot water systems • a.Natural Gas Tankless Cap:1 gallons B. Floor Types (3621.0 sqft.) Insulation Area EF:0.900 a.Slab-On-Grade Edge Insulation R=0.0 2696.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 755.00 ft2 None c.other(see details) R= 170.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 35:10 PASS Glass/Floor Area: 0.113 Total Standard Reference Loads: 66.43 I hereby certify that the plans and specifications covered by Review of the plans and �,t```.1 E.STAr';'�.,,. this calculation are in compliance with the Florida Energy specifications covered by this 4.,.-- .14,'a z •.;O,s':y calculation indicates compliance # �a:u„ °f:4,••,., ,° s Code. r: .-i? =.. a / with the Florida Energy Code. t~:n(Iv,-.;. �•:.•° ,�,0 ,�/i% 73'6'- Before construction is completed :: • � ".; PREPARED Y: -.�-� -� �d; 6 S w this building will be inspected for i c�•:_44,'...1) r DATE: compliance with Section 553.908 y *' a. * ' I hereby certify that this buildin•, •s designed,is in compliance Florida Statutes. .e.-;' +�,•'.5A• Y fy g � ...... .... with the Florida Energy ode. ... 0b �` . OWNER/AGENT: -�._Ly�• BUILDING OFFICIAL: DATE: '7 2-1 DATE: �7 3/' /r---- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist ______ i � REVISED FILECOPY g� am Page 1 of6 - 7/16/2015 2:49 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: Anastasia Bonus 3621 Left Bedrooms: 4 Address Type: Street Address • Building Type: User Conditioned Area: 3621 Lot# Owner. Toll Architecture Total Stories: 2 Block/SubDivision: . #'of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brithers Inc. Rotate Angle: 0 Street: 1705 Maritime Oak Dr Permit Office: St.Johns Cross Ventilation: No County: Duval Jurisdiction: 651000 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL,. New/Existing:. New(From Plans) Comment • CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.'5% 2.5% Winter Summer Degree Days Moisture Range FL,St.Augustine FL_JACKSONVILLE_INT 2 32 93 70 75 1281 64 Medium BLOCKS Number Name Area Volume , 1 •Blockt 2696 26960 .2 Block2 925 8325 • SPACES . � Number Name Area Volume Kitchen Occupants Bedrooms Intl!ID Finished Cooled Heated 1 Main 2696 26960 Yes 4 3 1 Yes Yes Yes • .2 2nd Floor 925 8325 No 1 1 1 Yes Yes Yes FLOORS ✓ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet V 1 Slab-On-Grade Edge lnsulatio Main 268 ft 0 2696 ft2 -- 0 0 1 / v 2 Floor Over Other Space 2nd Floor 755 ft2 0 0 0 1 3 Floor over Garage 2nd Floor _— ____ 170 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 1 Gable or shed Composition shingles 3319 ft2 838 ft2 Medium 0.6 N 0.9 No 0 30.3 ATTIC ,V/ # Type Ventilation Vent Ratio(1 in) Area RBS IRCC • 1 Full attic Vented 300 2866 ft2 N N • t I 7/16/2015 2:49 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 1 CEILING V' # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 / 1 Knee Wall(Vented) Main 19 • 125 ft2 0.11 Wood V 2 Under Attic(Vented) 2nd Floor 38 925 ft2 0.11 Wood • 3 Under Attic(Vented) Main . 38 1941 ft2 0.11 .. • Wood • WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below • . Space Q_Vaine Et In Ft In Area • R-Value Fraction Absor Grade%_ 1 NW Exterior Frame-Wood 2nd Floor 19 33 6 9 0 301.5 ft2 • 0 0.23 0.8 0 i NW Exterior Frame-Wood Main 19 58 8 10 .0 . 586.7.ft2 0 0.23 0.8 0 i V 3 SW Exterior Frame-Wood 2nd Floor 19 . 19 0 . 9 0 171.0 ft2 0 0.23 0.8 0 . SW Exterior Frame-Wood Main 19 18 2 10 0 181.7 ft2 0 0.23 0.8 0 5. SE Exterior Frame-Wood 2nd Floor 19 3 6 9 0 31.5 ft2 0 0.23 0.8 0 6 SE Exterior Frame-Wood Main 19 82 0 10 0 820.0 ft2 0 0.23 0.8 0 NE Exterior Frame-Wood 2nd Floor 19 19 0 9 .0 171.0 ft2. 0 0.23 0.8 0 NE Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.8 0 • i 9 SW Garage Frame-Wood Main 13 28 • 0 9 .0 252.0 ft2..• 0 0.23 0.8 0 • ' • DOORS ii1/ # Ornt Door Type Space Storms U-Value Ft Width In FHeightln Area 1 SW Insulated Main None .54 3 8 24 ft2 V 2 SW Insulated Main None 39 .2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening • / ,VJ 1 NW 2 Vinyl Low-E Double Yes 0.34 0.27 60.0 ft2 1 ft 4 in 11 ft 6 in None Exterior 5 3 a` 2 NW 1 Vinyl Low-E Double Yes 0.34 0.27 60.0 ft2 1 ft 4 in 1 ft 6 in None Exterior 5 V1 3 SW 3 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 1 ft 4 in 1 ft 6 in None Exterior 5 V/ 4 SW 4 Vinyl Low-E Double Yes 0.34 0.27 38.0 ft2. 3 ft 4 in 1 ft 6 in None Exterior 5 I( 5 SE 6 Vinyl Low-E Double Yes 0.34 0.27 45.0 ft2 1 ft 4 in 1 ft 6 in None Exterior 5 6 NE 8 Vinyl Low-E Double Yes 0.34 0.27 128.0 ft2 18 ft 2 in• 1 ft 6 In None Exterior 5 1• • • • • 7 NE . 8 Vinyl Low-E Double Yes 0.34 0.27 • • 30.0ft2 1 ft 4 in • 1 ft 6 in• None Exterior 5. V 8 SE 6 Vinyl Low-E Double Yes 0.34 0.27 19.0 ft2 1 ft 4 in 1 ft 6 in None Exterior 5 V • 9 NE 7 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 1 ft 4 in 1 ft 6 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 .602 ft2 432 ft2 64 ft 9 ft 1 i li 1 C 7/16/2015 2:49 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Software Page 3 of 6 ! INFILTRATION . #. Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Best Guess .0003 2849.4 156.43 294.18. .2844 4.8452 1 i HEATING,SYSTEM , • ,1'/// # System Type Subtype Efficiency Capacity Block Ducts V/ 1 Electric Heat Pump None HSPF:8 18 kBtu/hr 2 sys#2 • f! 2 Electric Heat Pump None HSPF:8 -36 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:14 18 kBtu/hr 540 cfm 0.699999 2 sys#2 V 2 Central Unit Split SEER:14 36 kBtu/hr 1080 cfm - 0.7 1 sys#1. • HOT WATER SYSTEM ! l V # System Type SubType Location EF Cap Use SetPnt Conservation i / ' V 1 Natural Gas Tankless Exterior 0.9 .1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM / V FSEC Collector Storage Cart # Company Name I None None System Model# Collector Model# Area Volume FEF ft DUCTS / --Supply--- —Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area .Leakage Type Handler TOT OUT QN RLF Heat Cool J1 Attic 6 253 ft2 Attic 123 ft' Default Leakage Attic (Default) (Default) 2 2 V 2 Attic 6 200 ft' Attic 85 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans:Venting .lx Jan Feb €Xi Mar [Xi Apr ' May Jun lX Jul •lX Aug Sep . [X Oct • [X Nov € 13,: • i — . i I Page 7/16/2015 2:49 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Pa 9 a 1 Thermostat Schedule: HERS 2006 Reference Hours ' Schedule Type 1 2 •3 4 5 6 7 8 9 10 11 12 F Cooling(WD) AM 78 78 78 78 78 . 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 7.8 78 78 78 i Heating(WD) AM 66 66 66 66 66 68 68 68 .. 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) • AM 66 66. 66 66 66 68 68 68 68 68 68 68 • PM 68 68 68 68 68 68 68 68 68 68 66 66 ) . _ ... . i . . 1 , � k 1 1 • 7/16/2015 2:49 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 1 i FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 1705 Maritime Oak pr PERMIT#: Atlantic Beach, FL, - . . . MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and • doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403:1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, , programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. ( Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and �) sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. I Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in \ Table 403.4.3.2. Provide switch or clearly marked circuit breaker .1 (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 • +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical �, ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1. &Spas HP shall have the capability of operating at two or more speeds. Spas }, and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13)..Heat pump pool heaters • minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per • Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two ---' ---- — - —.-------- .- -...—_ --- —-- • -- "- or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. N 7/16/2015 2:49 PM EnergyGaugee USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 li . 1 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD I ESTIMATED ENERGY PERFORMANCE INDEX* = 53 The lower the EnergyPerformance Index,the more efficient the home. . 1705 Maritime Oak Dr, Atlantic Beach, FL, - 1. New construction or existing - • New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 2663.30 ft_ 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 252.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? • No a.Under Attic(Vented) • R=38.0 2866.00 ft2 6. Conditioned floor area(ft2) • 3621 b.Knee Wall(Vented) R=19.0 125.00 ft2 c.N/A R= ft2 7. Windows"" Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.34 410.00 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 253 SHGC: SHGC=0.27 • b.Sup: Attic,Ret:Attic,AH:Attic 6 200 I b. U-Factor: N/A ft2 i SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 18.0 SEER:14.00 SHGC: b.Central Unit 36.0 SEER:14.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 18.0 HSPF:8.00 Area Weighted Average Overhang Depth: 6.774 ft. b.Electric Heat Pump 36.0 HSPF:8.00 Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14.Hot water systems Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2696:00 ft2 a.Natural Gas EF:0.9 b.Floor Over Other Space R=0.0 755.00 ft2 b. Conservation features • c.other(see details) R= 170.00 ft2 None i 15.Credits . Pstat . I certify that this home has complied with the Florida Energy Efficiency Code for Building 4<<�,'"` 9Y Y 9 4IIIE srg1, .„ • Construction through the above energy saving features which will be installed (or exceeded) •�o:._.('...= ..` o . in this home before final inspection. Otherwise, a new EPL Display Card will be completed ' •, /.144,'1,1,...,...n•-.. based on installed Code c• if ant features. ; ....411,A,•,:, ,14.,i',s,,,„,or�• mss.. :L-+p Builder Signature: l 1 -mil./A'`' Date: 211 19 to,... !,.,.j fl Address of New Home: i 1DS t V�lAyIll lilt lMt.-I i City/FL Zip: 33 4;4,c.._•. . .A.s 1 . •*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient • mortgage(EEM) incentives'if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) • 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. • EnergyGauge®USA-FlaRes2010 Section 405,4.1 Compliant Software. ,J I ' TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Anastasia Bonus 3621 Left Builder Name: Toll Brithers Inc. Street: 1705 Maritime Oak Dr Permit Office: St.Johns City,State,Zip: Atlantic Beach,FL, - Permit Number: Owner: Toll Architecture Jurisdiction: 651000 1 Design Location: FL,St.Augustine COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in . substantial contact and continuous alignment with building envelope . I air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. . Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with i insulation and any gaps are sealed. �) Attic access (except unvented attic), knee wail door, or drop down stair is sealed. Corners and headers are insulated. Walls Junction of foundation and sill plate is sealed. � Windows and doors Space between window/door jambs and framing is sealed. �. Rim joists Rim joists are insulated and include an air barrier. . Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. i Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. N. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. N Exception—fixtures in conditioned space. • Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing,or sprayed/blown insulation extends behind piping and wiring. • 1 Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier . separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are. • N installed. Common wall Air barrier is installed in common wall between dwelling units. �, HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. \ Fireplace Fireplace walls include an air barrier. NI I f EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software { • MCGowans Manual S Compliance Report Job: 1705 Maritime Oak Dr. Date: 7/16/2015 Conditioning (Rest of House) By: Stephen J Barber S 0*300(l£AKtall+ McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:pacobs @mcgowansac.com Web.www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 27258 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 4361 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 31619 Btuh Indoor RH: 50% Estimated airflow: 1100 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0360000A+FB4CNP036L Actual airflow: 1100 cfm Sensible capacity: 28403 Btuh 104%of load Latent capacity: 4361 Btuh 100%of load Total capacity: 32764 Btuh 104%of load SHR: 87% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 30630 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F '1l Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0360000A+FB4CNP036L Actual airflow: 1100 cfm 1 Output capacity: 33000 Btuh 108%of load Capacity balance: 30 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1100 cfm Output capacity: 9.7 kW 108%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jul-16 14:50:08 wrightsoft Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 A ...300 RES NC1Toll Brothers\Lot 93 AB Manual S.rup Calc=MJ8 House faces:SW 1 McGowari'S Manual S Compliance Report Job: 1705 Maritime Oak Dr. Date: 7/16/2015 He,ating4Air 1 UP By: Stephen 16/201 J Barber Conditioning "-; (" McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park"Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email.jjacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl 1 Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 14930 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.2°F Latent gain: 1722 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 16652 Btuh Indoor RH: 50% Estimated airflow: 593 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A+FB4CNP018L Actual airflow: 593 cfm Sensible capacity: 14930 Btuh 100%of load Latent capacity: 1722 Btuh 100%of load Total capacity: 16652 Btuh 100%of load SHR: 90% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 11409 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A+FB4CNP018L Actual airflow: 593 cfm Output capacity: 17800 Btuh 156%of load Capacity balance: 22 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 593 cfm Output capacity: 3.3 kW 98%of load Temp. rise: 17 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jul-16 14:50:08 wrightsoft° Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 ...300 RES NC1Toll BrothersQLot 93 AB Manual S.rup Calc=MJ8 House faces:SW McGowan Project Summary Job: 1705 Maritime Oak Dr. J � Date: 7/16/2015 Ne;afiny&Air c (Rest of House) By: Stephen J Barber Conditioningir Y' P '--*,ro4�,"-* C' McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey(Slmcgowansac.corn Web:www.mcgowansac.com Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Notes: The Anastasia Desi. n Information Weather: Jacksonville, FL, US i Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M . Relative humidity 50 % Moisture difference 52 grin) I Heating Summary Sensible Cooling Equipment Load Sizing Structure 24937 Btuh Structure 14783 Btuh Ducts 3415 Btuh Ducts 3992 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh 1 Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28352 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 26462 Btuh Method Simplified Latent Cooling Equipment Load Sizing I Construction quality Average Fireplaces 0 Structure 3335 Btuh I Ducts 670 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2696 2696 Equipment latent load 4755 Btuh Volume(ft3) 26773 26773 Air changes/hour 0.25 0.13 Equipment total load 31217 Btuh Equiv. AVF (cfm) 112 60 Req. total capacity at 0.70 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade I Model CH14NB037 Cond CH14NB037 AHRI ref Coil FB4CNP036 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 23800 Btuh Heating output 34000 Btuh @ 47°F Latent cooling 10200 Btuh Temperature rise 27 °F Total cooling 34000 Btuh 1 Actual air flow 1133 cfm Actual air flow 1133 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.060 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i i 1 wrightsoft Comfort Builder by Wrighlsofl 15.0.17 RSU12270 2015-Jul-16 15:04:07 Page 1 iCA ...NC\Toll Brothers\Anastasia Bonus 3621 left.rup Calc=MJ8 Front Door faces:SW I 1 • . McGowan, Project Summary Job: 1705 Maritime Oak Dr. Heating&Air R Date: 7/16/2015 1 Conditioning`���! up By: Stephen J Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Pro"ect Information i For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Notes: The Anastasia i Desi• n Information Weather: Jacksonville, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F i Daily range M Relative humidity 50 % Moisture difference 52 gr./lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 8285 Btuh Structure 7326 Btuh I Ducts 1272 Btuh Ducts 1563 Btuh i Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 9557 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 14004 Btuh i Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1361 Btuh { Ducts 262 Btuh IJ Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 925 925 Equipment latent load 2049 Btuh Volume(ft3) 8087 8087 Air changes/hour 0.37 0.20 Equipment total load 16053 Btuh Equiv.AVF (cfm) 50 27 Req. total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB018 Cond CH14NB018 AHRI ref Coil FB4CNP018 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input . Sensible cooling 12460 Btuh Heating output 17200 Btu h @ 47°F Latent cooling 5340 Btuh Temperature rise 26 °F Total cooling 17800 Btuh Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.062 cfm/Btuh Air flow factor 0.067 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Jul-1615:04:07 __ wrightsot Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 ACCA ...NC1Toll Brothers\Anastasia Bonus 3621 left.rup Cale=MJ8 Front Door faces:SW ''= I''r. — First Floor i ��� 16 x 16 :J Ma,,tcr B;ith 14" A 3" an Master Bedroom 1 10 x 6 6" i i 4 x 8 10 I (01 4" • — my 3"Fan i his 8 x 4 hers 10' 8 x 4 4•• 2-way 4 6x12 - 3"Fan ; 1ax6•, • i 14 6" Oi ••ath 3 4x8 Bedroom ' 4- 12x12 8" 2-way ' 14x14 6x12 I Great oos, 10x6 g.. 6" 1 ! 2-way j L Re eat 6x12 Sup Riser re 16 Ret f S 14'"Riser Sup Riser 14 12 x 12 10" I 8 stairs Ret Riser 18" 10"O 4"8 x 4 10 x 10 Bedroom 3■ 4 x 8 g • Pantry Haft 1 4" • 1:ath 2 ,Ldrv.10 x 10 • 12x6 �5 4x8 4" 12x6 ., 3"Fan 24 x 18 ., X18" r- . // Foyer Dininq 1 Garage 10x6 12x6 6" Study , 1.7, _., Job #: 1705 Maritime Oak Dr. McGowan's Heating & Air Conditions... Scale: 1 : 121 Performed by Stephen J Barber for: Page 1 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.17 RSU12270 Ponte vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Jul-16 15:04:24 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey @mcgowansac.com ...rslAnastasia Bonus 3621 left.rup III www.lollbrothers.corn smerten @tollbrothersinc.com N • up J uric 8x4 4" 12x,2 3"Fan 1),,,1 4 10"r .9 •.ath 14 x 6 8" 8x4 4 attic CAD x 18 14" 10x6 10x6 • 14.. J k!t Sup Riser 16 Ret Riser 10" 16" 14" 18 10 Sup Riser 10" 12x6 12x6 CI Ret Riser 7" 7" 12x12 18" 10" bonus room i fy� 8x4 4" b wic Job#: 1705 Maritime Oak Dr. McGowan's Heating & Air Conditions... Scale: 1 : 121 Performed by Stephen J Barber for: Page 2 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.17 RSU12270 Ponle Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Jul-16 15:04:24 Phone:(904)217-0739 Fax (904)814-8173 www.mcgowansac.com korey @mcgowansac.com ...rs\Anastasia Bonus 3621 left.rup www.tollbrothers.com smerten(8ltollbrothersinc.com 1 McGowan' Duct System Summary Job: 1705 Maritime Oak Dr. j Heating&Air ( ��' Date: 7/16/2015 Condirp�iny uQe.! (Rest of House) By: Stephen J Barber C�c�f'M.�Y LK.7.,'• I O_ McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey @mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.366/0.134 in H2O 0.366/0.134 in H2O Lowest friction rate 0.086 in/100ft 0.086 in/100ft Actual air flow 1133 cfm 1133 cfm Total effective length (TEL) 581 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk Bath 2 h 197 8 5 0.087 4.0 Ox 0 VIFx 114.8 305.0 st10 Bedroom 2 c 1032 46 62 0.110 6.0 Ox 0 VIFx 82.3 250.0 st9 Bedroom 3 c 1288 77 78 0.087 7.0 Ox 0 VIFx 113.8 305.0 st10 Dining c 1651 84 100 0.184 7.0 Ox 0 VIFx 29.5 170.0 st6 Foyer h 2681 107 93 0.171 6.0 Ox 0 VIFx 39.1 175.0 st6 Great Room-A c 2089 110 126 0.187 7.0 Ox 0 VIFx 31.3 165.0 st7 Great Room-B c 2089 110 126 0.175 7.0 Ox 0 VIFx 39.8 170.0 st7 Great Room-C c 2089 110 126 0.175 7.0 Ox 0 VIFx 39.8 170.0 st7 Ldry. h 240 10 8 0.086 4.0 Ox 0 VIFx 120.8 305.0 st10 Master Bath h 2764 110 58 0.105 6.0 Ox 0 VIFx 82.8 265.0 st11 Master Bedroom h 1929 77 75 0.105 7.0 Ox 0 VIFx 84.6 265.0 st11 Master Bedroom-A h 1929 77 75 0.106 7.0 Ox 0 VIFx 80.3 265.0 st11 Pantry h 155 6 4 0.180 4.0 Ox 0 VIFx 28.7 175.0 st6 Retreat c 1081 51 65 0.104 6.0 Ox 0 VIFx 92.3 260.0 st9 Study c 1927 114 116 0.171 7.0 Ox 0 VIFx 39.3 175.0 st6 bath 3 c 9 0 1 0.108 4.0 Ox 0 VIFx 84.3 255.0 st9 hers h 559 22 8 0.106 4.0 Ox 0 VIFx 85.3 260.0 st9 his c 5 0 0 0.105 4.0 Ox 0 VIFx 87.8 260.0 st9 toilet h 330 13 6 0.105', 4.0 Ox 0 VIFx 84.4 265.0 st11 .` W r 1 ht$c}ft' 2015-Jul-16 15:04:07 9 Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 ACLAN ...NC\Toll Brothers'Anastasia Bonus 3621 left.rup Calc=MJ8 Front Door faces:SW ! Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 311 314 0.171 575 10.0 0 x 0 VinIFIx st2 st10 Peak AVF 94 91 0.086 213 9.0 0 x 0 VinIFIx st9 st9 Peak AVF 214 227 0.086 417 10.0 0 x 0 VinIFIx st8 st11 Peak AVF 278 214 0.105 509 10.0 0 x 0 VinIFIx st8 st8 Peak AVF 492 441 0.086 460 14.0 0 x 0 VinIFIx st7 st7 Peak AVF 822 819 0.086 589 16.0 0 x 0 VinIFIx st3 st2 Peak AVF 311 314 0.171 575 10.0 0 x 0 ViniFlx st3 Peak AVF 822 819 0.086 589 16.0 0 x 0 VinIFIx Return Branch Detail Table _ Grill Htg CIg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb5 Ox 0 508 476 155.6 0.086 475 14.0 Ox 0 VIFx rb3 Ox 0 625 657 139.7 0.096 372 18.0 Ox 0 VIFx 2015-Jul-1615:04:07 wrightsoft Comfort Builder by Wrighlsoft 15.0.17 RSU12270 Page 2 i ACLA ...NC\Toll Brothers\Anastasia Bonus 3621 left.rup Cale=MJ8 Front Door faces:SW ■ MCGowan'S Duct System Summary Job: 1705 Maritime Oak Dr. Heating&Air �J Date: 7/16/2015 Conditioning �i Up By: Stephen J Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey @mcgowansac.com Web:www.mcgowansac.com • Project Information . For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.336/0.164 in H2O 0.336/0.164 in H2O Lowest friction rate 0.156 in/100ft 0.156 in/100ft ! Actual air flow 593 cfm 593 cfm Total effective length (TEL) 320 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk b wic h 740 46 31 0.156 4.0 Ox 0 VIFx 34.7 180.0 st5 bath 4 h 466 29 16 0.166 4.0 Ox 0 VIFx 22.3 180.0 st4 bed 4-A c 2484 156 166 0.169 8.0 Ox 0 VIFx 18.2 180.0 st4 bonus room C 1593 90 106 0.160 7.0 Ox 0 VIFx 29.5 180.0 st5 bonus room-A C 1593 90 106 0.161 7.0 Ox 0 VIFx 28.9 180.0 st5 loft c 1119 74 75 0.167 6.0 Ox 0 VIFx 20.6 180.0 st4 loft-B C 1119 74 75 0.169 6.0 Ox 0 VIFx 18.9 180.0 st4 we h 553 34 18 0.159 4.0 Ox 0 VIFx 30.8 180.0 st4 Supply Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct + Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 368 350 0.159 675 10.0 0 x 0 VinIFIx st1 st5 Peak AVF 225 243 0.156 446 10.0 0 x 0 VinlFlx st1 st1 Peak AVF 593 593 0.156 555 1 14.0 0 x 0 VinIFIx t Wrl htsoft' 2015-Jul-16 15:04:07 �� 9 Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 3 ..NC\Toll Brothers\Anastasia Bonus 3621 left.rup Calc=MJ8 Front Door faces:SW i • r Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb11 Ox 0 135 137 82.1 0.200 251 10.0 Ox 0 VIFx rtl rb4 Ox 0 265 259 84.6 0.194 485 10.0 Ox 0 VIFx rt1 rb2 Ox 0 193 197 105.1 0.156 565 8.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rtl Peak AVF 593 593 0.156 555 14.0 0 x 0 VinIFIx 2015-Jul-16 1501:07 .c . wrightsoft° Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 4 ...NC\Toll BrothersWnastasia Bonus 3621 left.rup Calc=MJ8 Front Door faces:SW