Loading...
1765 MARITIME OAK DR - HVAC DUCT LEAKAGE TEST Jacksonville Building Science, LLC 450 -106 State Rd 13 N Suite 132 Jacksonville, FI 32259 Phone: 904 - 807 -3540 OFFICE COPY Fax: 886 - 678 -6204 Date of Test: December 30, 2015 Technician: M O'Donoughue Test File: Riverside ABCC 103 Outside Customer: Riverside Homes Building Address: Riverside ABCC 103 414 Old Hard Road 1765 Maritime Oak Dr. Suite 502 Atlantic Beach, Fl Fleming Island, FI Phone: (904) 264 -6553 Fax: Test Results 1. Measured Duct Leakage: 12.7 CFM / 2.4 sq. in. ( +/_ 62265530476846642000000000000000 2. Duct Leakage as a Percent of System Airflow: 0.8 % 3. Duct Leakage as a Percent of Building Floor Area: 0.5 % 4. Leakage Split: Supply Side: Return Side: 5. Duct Leakage Curve: Flow Coefficient (C): 1.8 Exponent (n): 0.600 (Assumed) 6 Test Settings: Test Mode: Depressurization Test Pressure: 25.0 Pa Equipment: Series B Minneapolis Duct Blaster, S/N 001 Test Type: Outside Leakage (Combined Duct Blaster and Blower Door Test) Building and System Parameters: Floor Area: 2709 sq. ft. Average Supply Operating Pressure: Pa System Airflow: 1600 CFM Average Return Operating Pressure: Pa Supply Leakage Split: % Supply Leakage Penalty: Return Leakage Split: % Return Leakage Penalty: Percentage of Measured Leakage Connected to Outside: 100% (12.7 CFM) DUCT LEAKAGE TEST Page 2 Date of Test: December 30, 2015 Test File: Riverside ABCC 103 Outside Data Points - Data Entered Manually: Duct Fan Fan Flow Fan Pressure (Pa) Pressure (Pa) (CFM) % Error Configuration -25.0 -4.5 13 0.0 Ring 3 Comments