604 TIMBER BRIDGE LN - ENERGY SHEETS FILE COPY
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Crapps' Residence Builder Name: Holder Johnson
Street: Permit Office: Duval
City.State,Zip: Atlantic Beach,FL,32233- Permit Number:/$- S'FR -/5 0 7
Owner: Jurisdiction:
Design Location: FL, Jacksonville
1. New construction or existing New(From Plans) 9. Wall Types(2636.8 sqft.) Insulation Area
2. Single family or multiple family Single-family a. Frame-Wood,Exterior R=19.0 1438.30 ft'
b.Frame-Wood,Exterior R=13.0 816.00 ft'
3. Number of units,if multiple family 1 c Frame-Wood,Adjacent R=13.0 382.50 R'
4. Number of Bedrooms 4 d.N/A R= ft'
10.Ceiling Types(2095.0 sqft.) Insulation Area
5. Is this a worst case? Yes a. Under Attic(Vented) R=30.0 1510.00 ft?
6. Conditioned floor area above grade(ft') 2620 b. Knee Wall(Vented) R=19.0 585.00 ft'
Conditioned floor area below grade(ft') 0 A NIA R= ft'
11. Ducts R ft'
7. Wlndows(367.8 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 231
a. U-Factor: Dbi, U=0.34 367.83 ft'
SHGC: SHGC=0.34
b. U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 36.0 SEER:14.00
c. U-Factor. N/A ft'
SHGC: 13. Heating systems kBtu/hr Efficiency
'd. U-Factor: N/A ft' a. Electric Heat Pump 36.0 HSPF:8.00
SHGC:
Area.Weighted Average Overhang Depth: 6.405 ft.
Area Weighted Average SHGC: 0.340' 14. Hot water systems
8. Floor:Types:(262Q.0 wit.) Insulation Area a. Electric Cap:50:0.920
EF: 0.920
a. Slab-On-Grade Edge Insulation R=0.0 1510.00 ft' b. Conservation features
b.Floor Over Other Space R=0.6 1057.00 ft' None
c.other(see details) R= 53.00 ft' 15.Credits + None
Glass/Floor Area: 0.140 Total Proposed Modified Loads: 41.19 PASS
Total Standard Reference Loads: 57.47
I hereby certify that the plans and specifications covered by Review of the plans and /*foil Sr9TF3,
this calculation are in compliance with the Florida Energy specifications covered by this .: O ,-
Code. calculation indicates compliance .H : _ i
with the Florida Energy Code. ' g,.ua,-.-'0.•° ?• U L
PREPARED BY: Cristina McAnal ly p m•. . `
}� Before construction is completed �_ --.��:�
DATE: (DI.� /1 this building will be inspected for :0 . • : 1
compliance with Section 553.908 .Ems;r ; ,,
+ Florida Statutes.
I
hereby certify that this building,as designed,is in compliance 1 •- •'*
with the Florida Energy Co cOD WEB....'
OWNER/AGENT' 1 BUILDINGOFFICIAL:
DATE: (.v j 23/ IC' c•r+ A\ o /lc Or") DATE: •/
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
5/6/2015 11:30 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
i
PROJECT
Title: Crapps' Residence Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 2620 Lot# 169
Owner: Total Stories: 2 Block/SubDivision: Atlantic Bch CC
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Holder Johnson Rotate Angle: 90 Street:
Permit Office: Duval Cross Ventilation: County: Duval
Jurisdiction: Whole House Fan: City,State,Zip: Atlantic Beach ,
Family Type: Single-family FL , 32233-
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Block! 2620 25090
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms la! ID Finished Cooled Heated
1 1st Floor 1510 15100 Yes 2 1 1 Yes Yes Yes
2 2nd Floor 1110 9990 No 3 3 1 Yes Yes Yes
FLOORS
V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge lnsulatio 1st Floor 174 ft 0 1510 ft' __ 0 0.25 0.75
2 Floor over Garage 2nd Floor __ __ 53 ft2 0 0 0 1
3 Floor Over Other Space 2nd Floor -- __ 1057 ft2 0 0 0 1
ROOF
v' Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1749 ft2 0 ft2 Medium 0.96 No 0.9 No 0 30.3
/ ATTIC
V # Type Ventilation Vent Ratio(1 In) Area RBS IRCC
1 Full attic Vented 300 1510 ft2 N N
5/6/201511:30 AM EnergyGauge®USA- FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
c
CEILING
V # Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under Attic(Vented) 1st Floor 30 1510 ft' 0.11 Wood
2 Knee Wall (Vented) 2nd Floor 19 585 ft2 0.11 Wood
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
S C)rnt Tn Wall Type Space R-Vahie Ft In Ft In Area R-Valle Fra&inn Ahcnr r;rarle%
1 N=>E Exterior Frame-Wood 1st Floor 19 42 0 10 0 420.0 ft' 0 0.23 0.75 0
2 E=>S Exterior Frame-Wood 1st Floor 19 39 1 10 0 390.8 ft2 0 0.23 0.75 0
3 S=>W Garage Frame-Wood 1st Floor 13 21 2 10 0 211.7 ft2 0 0.23 0.75 0
4 W=>N Garage Frame-Wood 1st Floor 13 5 1 10 0 50.8 ft2 0 0.23 0.75 0
5 E=>S Garage Frame-Wood 1st Floor 13 12 0 10 0 120.0 ft2 0 0.23 0.75 0
6 S=>W Exterior Frame-Wood 1st Floor 19 20 10 10 0 208.3 ft2 0 0.23 0.75 0
7 W=>N Exterior Frame-Wood 1st Floor 19 41 11 10 419.2 ft2 0 0.23 0.75 0
8 N=>E Exterior Frame-Wood 2nd Floor 13 16 6 9 148.5 ft2 0 0.23 0.75 0
9 E=>S Exterior Frame-Wood 2nd Floor 13 28 10 9 259.5 ft2 0 0.23 0.75 0
10 S=>W Exterior Frame-Wood 2nd Floor 13 19 2 9 172.5 ft2 0.23 0.75 0
11 W=>N Exterior Frame-Wood 2nd Floor 13 26 2 9 235.5 ft' 0.23 0.75 0
DOORS
✓ # Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S=>W Wood 1st Floor None .46 2 8 6 8 17.8 ft2
2 S=>W Insulated 1st Floor None .46 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation(=>) changed to Worst Case.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>E 1 Vinyl Low-E Double Yes 0.34 0.34 72.0 ft2 10 ft 0 in 10 ft 0 in Drapes/blinds None
2 N=>E 1 Vinyl Low-E Double Yes 0.34 0.34 96.0 ft2 10 ft 0 in 10 ft 0 in Drapes/blinds None
3 E=>S 2 Vinyl Low-E Double Yes 0.34 0.34 8.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
4 E=>S 2 Vinyl Low-E Double Yes 0.34 0.34 8.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
5 E=>S 2 Vinyl Low-E Double Yes 0.34 0.34 20.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
6 S=>W 6 Vinyl Low-E Double Yes 0.34 0.34 13.3 ft2 7 ft 0 in 10 ft 0 in Drapes/blinds None
7 S=>W 6 Vinyl Low-E Double Yes 0.34 0.34 36.0 ft2 12 ft 0 in 10 ft 0 in Drapes/blinds None
8 W=>N 7 Vinyl Low-E Double Yes 0.34 0.34 20.0 ft2 1 ft 0 in 10 ft 0 in None None
9 N=>E 8 Vinyl Low-E Double Yes 0.34 0.34 30.0 ft2 1 ft 0 in 1 ft 0 in None None
10 E=>S 9 Vinyl Low-E Double Yes 0.34 0.34 15.0 ft2 1 ft 0 in 1 ft 0 in None None
11 S=>W 10 Vinyl Low-E Double Yes 0.34 0.34 7.5 ft2 1 ft 0 in 1 ft 0 in None None
12 S=>W 10 Vinyl Low-E Double Yes 0.34 0.34 12.0 ft2 1 ft 0 in 1 ft 0 in None None
13 S=>W 10 Vinyl Low-E Double Yes 0.34 0.34 15.0 ft2 1 ft 0 in 1 ft 0 in None None
14 W=>N 11 Vinyl Low-E Double Yes 0.34 0.34 15.0 ft2 1 ft 0 in 1 ft 0 in None None
5/6/2015 11:30 AM EnergyGauge®USA- FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
i
GARAGE
✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 492.66 ft2 439 ft2 56 ft 10 ft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Best Guess .0003 2061.7 113.18 212.86 .2844 4.9303
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8 36 kBtufir 1 sys#1
COOLING SYSTEM
✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER:14 36 kBtu/hr 1080 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.92 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ — Supply-- — Return
Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 231 ft2 2nd Floor 75 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1
5/6/2015 11:30 AM EnergyGauge> USA- FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
,
TEMPERATURES
Programable Thermostat:N Ceiling Fans:
Cooling ]Jan [ ]]Feb Mar Apr May X Jun X Jul X Au X Se Oct Nov ]Dec
Heating lX]Jan 4X] Feb f XX Mar f I Apr f 1 May/ 4 N Jun 4 N Jul I N Aug 4 i Sep f 1 Oct f XI Nov f X]Dec
Venting [ ]Jan ]]Feb IX Mar [X Apr [ May [ Jun [ Jul Aug [ Sep IX Oct [X Nov [ 1 Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 0 1 - Electric Heat Pump 0% 1 -Central Unit `
5/6/201511:30 AM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
B
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT#:
Atlantic Beach, FL,32233-
MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
doors=0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces:
gasketed doors&outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and
controls cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers,shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric)or shutoff(gas). Circulating system pipes insulated to=R-2
+accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70%of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78%(82%after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed&attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/kneewalls 405.2.1 R-19 space permitting.
5/6/2015 11:30 AM EnergyGauge®USA- FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 72
The lower the EnergyPerformance Index,the more efficient the home.
, Atlantic Beach, FL, 32233-
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 1438.30 ft'
b.Frame-Wood,Exterior R=13.0 816.00 ft'
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 382.50 ft'
4. Number of Bedrooms 4 d.N/A R= ft'
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1510.00 ft'
6. Conditioned floor area(ft') 2620 b.Knee Wall(Vented) R=19.0 585.00 ft2
7. Windows** Description Area c.N/A R= ft2
a. U-Factor: Dbl,U=0.34 367.83 ft2 11.Ducts R ft'
a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 231
SHGC: SHGC=0.34
b. U-Factor: N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 36.0 SEER:14.00
SHGC:
d. U-Factor: N/A ft' 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 36.0 HSPF:8.00
Area Weighted Average Overhang Depth: 6.405 ft.
Area Weighted Average SHGC: 0.340
8. Floor Types Insulation Area 14.Hot water systems
a.Slab-On-Grade Edge Insulation R=0.0 1510.00 ft2 a.Electric Cap:50 gallons
EF:0.92
b.Floor Over Other Space R=0.0 1057.00 ft2
c.other(see details) R= 53.00 ft2 b. Conservation features
None
15.Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building iESTgT••:
Construction through the above energy saving features which will be installed (or exceeded) �O ;z:, Fo,�
in this home before final inspection. Otherwise, a new EPL Display Card will be completed w�'' '.t.'
vet
based on installed Code compliant features.
Builder Signature: _ Date: 23i I S 1° �A a
Address of New Home:(.0(1-1 -(t bey Br td9 e L0.1) City/FL Zip: AA-tan-M., \.:11;•••••
cO3For1G1c`. 30033 1WT
.
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
ID
TABLE 402.4.2
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Crapps'Residence Builder Name: Holder Johnson
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach,FL,32233- Permit Number:
Owner: Jurisdiction:
Design Location: FL,Jacksonville
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in
substantial contact and continuous alignment with building
envelope air barrier.
Breaks or joints in the air barrier are filled or repaired.
Air-permeable insulation is not used as a sealing material.
Air-permeable insulation is inside of an air barrier.
Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with
insulation and any gaps are sealed.
Attic access (except unvented attic), knee wall door, or drop down
stair is sealed.
Walls Corners and headers are insulated.
Junction of foundation and sill plate is sealed.
Windows and doors Space between window/door jambs and framing is sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including Insulation is installed to maintain permanent contact with underside
above-garage and cantilevered of subfloor decking.
floors)
Crawl space walls Insulation is permanently attached to walls.
Exposed earth in unvented crawl spaces is covered with Class I
Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening
to exterior or unconditioned space are sealed.
Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by
sprayed/blown insulation.
Garage separation Air sealing is provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall.
Exception—fixtures in conditioned space.
Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is
cut to fit around wiring and plumbing, or sprayed/blown insulation
Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier
separating them from the exterior wall.
Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are
installed.
Common wall Air barrier is installed in common wall between dwelling units.
HVAC register boots HVAC register boots that penetrate building envelope are sealed to
subfloor or drywall.
Fireplace Fireplace walls include an air barrier.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
I I
Manual S Compliance Report Job:
+I+ wrightsoft
Date: 2015
Entire House By:
A/C Designs of St. Augustine Inc.
103 Liberty Center Place,St.Augustine.FL 32092 Phone:904-829-8898 Fax:904-829-6587
Project Information
For: Holder Johnson
Fl
Cooling Equipment
Design Conditions
Outdoor design DB: 95.0`F Sensible gain: 26926 Btuh Entering coil DB: 76.4°F
Outdoor design WB: 76.0'F Latent gain: 3765 Btuh Entering coil WB: 63.2°F
Indoor design DB: 75.0'F Total gain: 30691 Btuh
Indoor RH. 50% Estimated airflow: 1140 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Goodman Mfg. Model: SSZ140361B+AVPTC42D14A
Actual airflow: 1140 cfm
Sensible capacity: 25650 Btuh 95% of load
Latent capacity: 8550 Btuh 227% of load
Total capacity: 34200 Btuh 111% of load SHR: 75%
Heating Equipment
Design Conditions
Outdoor design DB: 34.0°F Heat loss: 25544 Btuh Entering coil DB: 69.4°F
Indoor design DB: 70.0'F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Goodman Mfg. Model: SSZ140361B+AVPTC42D14A
Actual airflow: 1140 cfm
Output capacity: 34200 Btuh 134% of load Capacity balance: 29 `F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1140 cfm
Output capacity: 7.5 kW 100% of load Temp. rise: 31 `F
The above equipment was selected in accordance with ACCA Manual S.
}.1+ wrl htsoft
2015-Jul-24 13:age 1
"I" g Right-Suites:Universal 2015 15.0.19 RSU01648 Page 1
ACCT\ ...er-Johnson\Lot Specific\Crapps'Resldence.rup Cate=MJ8 Front Door faces:NE
Project Summary Job:
+ wrightsoft � � Date: 2015
Entire House By:
A/C Designs of St. Augustine Inc.
103 Liberty Center Place,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587
Pro'ect Information
For: Holder Johnson
Fl
Notes: Crapps' Residence
Lot 169 Atlantic Beach CC
Faces North East
Desi ' n Information
Weather: Jacksonville Cecil Field NAS, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 34 °F Outside db 95 'F
Inside db 70 °F Inside db 75 ''F
Design TD 36 °F Design TD 20 "F
Daily range M
Relative humidity 50 %
Moisture difference 40 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 23879 Btuh Structure 24408 Btuh
Ducts 1665 Btuh Ducts 2518 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 25544 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 26926 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2829 Btuh
Ducts 936 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft') 2620 2620 Equipment latent load 3765 Btuh
Volume (ft') 25090 25090
Air changes/hour 0.32 0.16 Equipment total load 30691 Btuh
Equiv. AVF (cfm) 134 67 Req. total capacity at 0.75 SHR 3.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make Goodman Mfg. Make Goodman Mfg.
Trade GOODMAN; JANITROL; AMANA DISTI... Trade GOODMAN; JANITROL; AMANA DISTI...
Model SSZ140361 B Cond SSZ140361 B
AHRI ref 5924429 Coil AVPTC42D14A
AHRI ref 5924429
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 25650 Btuh
Heating output 32000 Btuh @ 47"F Latent cooling 8550 Btuh
Temperature rise 26 °F Total cooling 34200 Btuh
Actual air flow 1140 cfm Actual air flow 1140 cfm
Air flow factor 0.045 cfm/Btuh Air flow factor 0.042 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft 2015-Jul-2413:03:35
g Right-Suite t Universal 2015 15.0.19 RSU01648 Page 1
ACCA .er-Johnson\Lot Specific\Crapps'Residence.rup Calc=MJ8 Front Door faces:NE
-1-1+ wrightsoft Right-J® Worksheet Job:
Entire House Date: 2015
By:
A/C Designs of St. Augustine Inc.
103 Liberty Center Place.SI.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587
1 Room name I Entire House 1st Floor
2 Exposed wall 174.0 ft 174.0 ft
3 Room height I 9.6 ft 10.0 ft heat/cool
4 Room dimensions 1510.0 x 1.0 ft
5 Room area 2620.0 ft' 1510.0 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load
number (Btuh/ft'-"F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12E-Osw 0.068 ne 2.45 1.52 379 274 671 417 208 138 338. 210
. -0 61A 0.340 ne 12.24 28.23 85 0 1040 2400 50 0 612 1412
D 11J0 0.600 ne 21.60 18.90 20 20 432 378 20 20 432 378
W 12E-Osw 0.068 se 2.45 1.52 604 569 1393 867 370 350 857 533
11 t-f 61A 0.340 se 12.24 27.02 35 11 428 946 20 3 245 540
1Q,1 12E-Osw 0.068 sw 2.45 1.52.52 569 371 908 565 420 252 617 384
�( 61A 0.340 sw 12.24 13.86 198 396 2424 2744 168 168 2056 2328
W I 12E-Osw 0.068 nw 2.45 1.52 611 560 1371 853 350 314 769 478
P I61A 0.340 nw 12.24 28.23 51 0 624 1440 36 0 441 1016
12C-Osw 0.091 - 3.28 1.51 330 312 1022 471 330 312 1022 471
I-D 11D0 0.390 ne 14.04 12.28 18 18 253 221 18 18 253 221
C 16D-30td 0.032 ne 1.15 1.12 1510 1510 1740 1691 1510 1510 1740 1691
F 20P-19c 0.050 - 1.80 0.75 53 53 95 40 0 0 0 0
F 22A-tpl 0.989 ne 35.60 0.00 1510 174 6195 0 1510 174 6195 0
I
I
6 c)AED excursion 3757 3427
Envelope loss/gain 18596 16790 15575 13090
12 a) Infiltration 5283 1468 3293 915
b) Room ventilation 01 0 0 0
13 Internal gains: Occupants @ 250 5 1250 2 500
Appliances/other 4900 4900
Subtotal(lines 6 to 13) 23879 24408 18868 19405
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 23879 24408 18868 19405
15 Duct loads 7% 10% 1665 2518 3% 7% 555 1388
Total room load 25544 26926 19423 20793
Air required(cfm) 1 140 1140 867 880
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft 2015-Jul-24 13:03:35
:�:A Rlght•Sulte:)Universal 2015 15.0.19 RSU01648 Page 1
...er-Johnson\Lot Specific\Crapps'Residence.rup Caic=MJ8 Front Door faces:NE
+ wrightsoft Right-J® Worksheet Job:
Entire House Date: 2015
By:
A/C Designs of St. Augustine Inc.
103 Liberty Center Place.St.Augustine.FL 32092 Phone:904-829-8898 Fax:904-829-6587
1 Room name I 2nd Floor
2 Exposed wall 0 ft
3 Room height 9.0 ft heat/cool
4 Room dimensions 1110.0 x 1.0 ft
5 Room area 1110.0 ft'
Ty Construction U-value Or HTM Area (ft') Load Area Load
number (Btuh/ft'-"F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 l./ 12E-Osw 0.068 ne 2.45 1.52 171 136 333 207
L—Gp, 61A 0.340 ne 12.24 28.23 35 0 428 988
11.10 0.600 ne 21.60 18.90 0 0 0 0
W 12E-Osw 0.068 se 1 2.45 1.521 234 219 536 334
11 (-0 61A 0.340 se 12.24 27.02 15 2 184 405
W 12E-Osw 0.068 sw 2.45 1.52 149 119 291 181
__G 61A 0.340 sw 12.24 13.86 30 30 367 416
WII 12E-Osw 0.068 nw 2.45 1.52 261 246 602 375
--G
L 61A 0.340 nw 12.24 28.23 15 0 184 423
P 12C-Osw 0.091 - 3.28 1.511 0 0 0 0
I-D 1 1 D0 0.390 ne 14.04 12.28 0 0 0 0
C 16D-30td 0.032 ne 1.15 1.12 0 0 0 0
F 20P-19c 0.050 - 1.80 0.75 53 53 95 40
F 22A-tpl 0.989 ne 35.60 0.001 0 0 0 0
I1
1
I -
6 c)AED excursion 331
Envelope loss/gain 3021 3700
12 a) Infiltration 1991 553
b) Room ventilation 0 0
13 Internal gains: Occupants @ 250 3 750
Appliances/other 0
Subtotal(lines 6 to 13) 5011 5003
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 5011 5003
15 Duct loads 22% 23% 1109 1130
Total room load 6121 6133
Air required(cfm) 273 260
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
w r i g h tsoft 2015-Jul-24 13:03:35
ACCP. Right-Sute7)Universal 2015 15.0.19 RSU01648 Page 2
...er-Johnson\Lot Specific\Crapps'Residence.rup Calc=MJ8 Front Door faces:NE
Level 1
Cafe
121 cfm 151 cfm
7 )U4 Family (1/8 " Owners
12"
117 cfm ,117 cfm
►�1�7 " FR-7"
Kitchen -
118 cfm Sup Riser 7 cfm 6,. 20 cfm_
.: 14
7" la 16 " j Pwdr 58 cfm \./ c
4 "
Pantry f .\O/Bath 4 � �
p,.
J \
• 20 cfm
7 1�i `� 6 Hall Laun
94 cfm
130 cfm Gallery
Stairs _( — 6
Dining
0.4 O/Wic
71 cfm
Foyer
Garage
Job#: A/C Designs Scale: 1 : 80
Performed for: Page 1
Holder Johnson 103 Liberty Center Place Right-Suiteii Universal 2015
Saint Augustine, FL 32092 115-Jul 2412:46:
Phone: 904-829-8898 Fax: 904-829-6587 2015-Jul- s Resi 8
der JohnsonlCrapps Residence.rup
level 2
I
Bed 3 7 cfm
1V Bath 2
6 cfm /4'
Bath 3 k4 95 cfm /
/4 7 " F`, Hall2
[ __
i. 10"
. , [
--16 " 12"
' 7" 7 ,
Bed raj . 7 r ( 1 Bed 2
�� -----1140 cfm 28 cfm
65 cfm 7 i Loft 73 cfm
•',Sup Riser
X16 " \\
i .T4 7"
18 cfm
Wic 4 Stairs 2 M
28 cfm
Open Below
Job#: A/C Designs Scale: 1 : 80
Performed for: Page 2
Holder Johnson 103 Liberty Center Place Right-Suite',1 Universal 2015
Saint Augustine, FL 32092 015-JululR412 6 124628
Phone: 904-829-8898 Fax 904-829-6587 hnson\Crap s Resid
...der JohnsonlCrapps Residence.rup
S
t
Duct System Summary Job:
+I+ wrightsoft D Date: 2015
Entire House By:
A/C Designs Plan: Crapps Residence
103 Liberty Center Place,Saint Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587
Project Information
For: Holder Johnson
Heating Cooling
External static pressure 0.22 in H2O 0.22 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.22 in H2O 0.22 in H2O
Supply/return available pressure 0.110/0.110 in H2O 0.110/0.110 in H2O
Lowest friction rate 0.100 in/100ft 0.100 in/100ft
Actual air flow 1140 cfm 1140 cfm
Total effective length (TEL) 231 ft
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk
Bath 2 c 160 6 7 0.100 4.0 Ox 0 VIFx 23.8 135.0 st3
Bath 3 c 144 4 6 0.100 4.0 Ox 0 VIFx 20.4 135.0 st4
Bed 2 h 1927 73 72 0.100 7.0 Ox 0 VIFx 21.3 135.0 st3
Bed 3 h 2501 95 69 0.100 7.0 Ox 0 VIFx 19.2 135.0 st3
Bed 4 h 1715 65 60 0.100 7.0 Ox 0 VIFx 19.0 135.0 st4
Cafe h 3186 121 81 0.100 7.0 Ox 0 VIFx 28.3 145.0 st5
Dining h 3419 130 84 0.100 7.0 Ox 0 VIFx 18.2 125.0 st2
Family c 2875 64 117 0.100 7.0 Ox 0 VIFx 30.6 150.0 st5
Family-A c 2875 64 117 0.100 7.0 Ox 0 VIFx 22.1 145.0 st5
Gallery h 2481 94 59 0.100 6.0 Ox 0 VIFx 14.3 125.0 st2
Kitchen c 2900 29 118 0.100 7.0 Ox 0 VIFx 18.9 125.0 st2
Laun h 537 20 14 0.100 4.0 Ox 0 VIFx 52.7 170.0 st6
Loft h 727 28 23 0.100 7.0 Ox 0 VIFx 18.1 135.0 st3
Loft-A h 727 28 23 0.100 7.0 Ox 0 VIFx 26.0 135.0 st3
of Bath c 1432 57 58 0.100 6.0 Ox 0 VIFx 48.8 170.0 st6
o/wc c 498 17 20 0.100 4.0 Ox0 VIFx 54.6 170.0 st6
o/wlc h 1867 71 52 0.100 6.0 Ox 0 VIFx 60.8 170.0 st6
Owners h 3973 151 140 0.100 8.0 Ox 0 VIFx 42.6 170.0 st6
Pwdr h 195 7 5 0.100 4.0 Ox 0 VIFx 18.0 125.0 st2
wic 4 h 462 18 13 0.100 6.0 Ox 0 VIFx 28.6 150.0 st4
2015-Jul-24 12:age 1
wrightsoft Right-Sulta'F)Universal 2015 15.0.19 RSU01648 Page 1
ACCA ...ft files ES\Holder Johnson\Crapps Residence.rup Calc=MJ8 Front Door faces:
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st6 Peak AVF 316 285 0.100 402 12.0 0 x 0 VinIFIx st5
st5 Peak AVF 564 601 0.100 562 14.0 0 x 0 ViniFlx st2
st2 Peak AVF 824 867 0.100 621 16.0 0 x 0 VinIFIx
st3 Peak AVF 229 193 0.100 292 12.0 0 x 0 VinIFIx st1
st4 Peak AVF 87 79 0.100 159 10.0 0 x 0 VinIFIx st1
st1 Peak AVF 316 273 0.100 226 16.0 0 x 0 VinIFIx
Return Branch Detail Table
Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk
rb2 Ox 0 1140 1140 0 0 0 0 Ox 0 VIFx
Wrl htsoft 2015-Jul-24 12:age 2
9 Right-Sulte'�:Universal 2015 15.0.19 RSU01648 Page 2
ACCP ...ft files ES\Holder Johnson\Crapps Residence.rup Calc=MJ8 Front Door faces: