Loading...
1753 MARITIME OAK DR - ENERGY SHEETS . . FiLE COPY i FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION I Florida Department of Business and Professional Regulation - Residential Performance Method Name: Toll Brothers 'N ilder a Project Name: CATALINA 3965 Left Builder Street: 1753 Maritime Oak Dr(lot 101) Permit Office: Atlantic Beach , City,State,Zip: Atlantic Beach,FL, Permit Number: /5--S Pg.-/S 4 Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(3856.8 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 3359.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=19.0 497.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 d.N/A R= ft2 ■ 4. Number of Bedrooms 5 10.Ceiling Types (3437.0 sqft.) Insulation Area 5. Is this a worst case? No .a.Under Attic(Vented) R=38.0 3437.00 ft2 R= ft2 6. Conditioned floor area above grade(fie) 3965 c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 6 516 7. Windows(520.6 sqft.) Description Area 2 b.Sup: Attic,c,Reet Att Attic,AH Attic 6 350 a. U-Factor: Dbl,U=0.34 520.56 fi SHGC: SHGC=0.27 ft2 12.Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a:Central Unit 42.0 SEER:14.00 SHGC: b.Central Unit 18.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A- ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: b.Electric Heat Pump 18.0 HSPF:8.20 • Area Weighted Average Overhang Depth: 3.369 ft. 14.Hot water systems Area Weighted Average SHGC: 0.270 a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (3965.0 sqft.) Insulation Area EF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 2817.00 ft2 b. Conservation features __ R=0.n 590.00 ft2 - -None b.Floor over Garage _ . c.other(see details) R= 558.00 ft2 - • 15.Credits None Total Proposed Modified Loads: 52.99 PASS Glass/Floor Area: 0.131 Total Standard Reference Loads: 77.62 0 0N....-........, I hereby certify that the plans and specifications covered by Review of the plans and ."44F11$E STAT'"a, this calculation are in compliance with the Florida Energy specifications covered by this 1*.c? �,s ,;..Q4%,,• calculation indicates compliance co s, f�.=/ ,�, Code. c"�, nn �"', -;;;:.:,,,;,,,.,,% p with the Florida Energy Code. -.4: u ,) *�,,,, :t� IAA.. /fi ,, Before construction is completed '^�' PREPARED. Y: : s4:__,� ._ : Ste/9 J this building will be inspected for 'I • C9 l lli DATE: compliance with Section 553.908 � I Florida Statutes. r.'fl4./w �r , ��,+,s,. I hereby certify that this building, as designed, is in compliance '4a��COp tiYB ',./ with the Florida Energy Co.e. ' rn ;h..,.,_�...f+�� OWNER/ G• T: BUILDING OFFICIAL: � ��� DATE: __ � DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 411 i• 5/19/2015 1:19 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: CATALINA 3965 Left Bedrooms: 5 Address Type: Street Address # lol Building Type: User Conditioned Area: 3965 2 Block/SubDivision: AB • Total Stories: Owner: Toll Brothers #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: 1753 Maritime Oak Dr(I • Permit Office: Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach, FL, Family Type: Single-family New/Existing: New(From Plans) Comment:. CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT .2 32 93 70 75 1281 49 Medium I . BLOCKS • Number Name Area Volume • 1 Block1 2817 28170 2 •Block2 1148 10332 _ SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 2817 28170 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 1148 10332 No 2 2 1 Yes Yes Yes FLOORS - • V # Floor Type Space Perimeter Perimeter R-Value .Area Joist R-Value Tile Wood Carpet . ::-:-, . _ 1.SIab-0n-Grade.Edge.lnsulatio 1st.Eloor_390.5ft_4 0 I 2 Floor Over Other Space 2nd Floor _� __ 528 ft2 0 0 0 1 3 Floor over Garage 2nd Floor ____ 590 ft2 0 0 0 1 2nd Floor 30 ft2 0 0 0 1 4 Raised Floor ---- °-- ROOF f� / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg} 1 Hip Composition shingles 3844 ft2 0 ft2 Medium 0.5 N 0.9 No 0 26.6 ATTIC • i i # Type Ventilation Vent Ratio(1 In) Area RBS IRCC 1 Full attic Vented 300 3437 ft2 N N 5/19/2015 1:19 PM EnergyGauge®Ener Gau e®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 i I CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type . I 1 Under Attic(Vented) 1st Floor 38 2289 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 38 1148 ft2 0.11 Wood WALLS / d Cavity Width Height Sheathing Framing Solar Below V 3t O.rnf A-[jo acent Wail Type Space P-value Et in Ft in AMA R-va!„P Fraction Absor._Grade%- _ 1 S Exterior Frame-Wood 1st Floor 19 8 9 10 0 87.5 ft2 0 0.25 0.8 0 I __2 SE Exterior Frame-Wood 1st Floor 19 40 6 12 0 486.0 ft2 0 0.25 0.8 0 _ 3 N Exterior Frame-Wood 1st Floor 19 3 6 12 0 42.0 ft2 • 0 0.25 0.8 0 • 4 NE Exterior Frame-Wood 1st Floor 19 49 0 12 0 588.0 ft2 0 0.25 0.8 0 _ 5 E Exterior Frame-Wood 1st Floor 19 3 6 12 0 42.0 ft2 0 0.25 0.8 0 6 NW Exterior Frame-Wood 1st Floor 19 33 5 12 0 401.0 ft2 0 0.25 0.8 0 I� 7 SW Exterior Frame-Wood 1st Floor 19 20 1 10 0 200.8 ft2 0 0.25 0.8 0 _8 SW Garage Frame-Wood 1st Floor 19 •49 9 10 0 497.5 ft2 0 0.25 0.8 0 _9 SE Exterior Frame-Wood 2nd Floor 19 40 9 9 0 366.8 ft2 0 0.25 0.8 0 _10 NE Exterior Frame-Wood 2nd Floor 19 39 9 9 0 357.8 ft2 0 0.25 0.8 0 _11 NW Exterior Frame-Wood 2nd Floor 19 46 .9 9 0 420.8 ft2 0 0.25 0.8 0 _____12 SW Exterior Frame-Wood 2nd Floor 19 .40 .9 9 0 366.8 ft2 0 0.25 0.8 0 r DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated 1st Floor None .6 3 8 24 ft2 2 SW Wood 1st Floor None .6 2 8 8 21.3 ft2 _____ _ WJNDOWS... - _` -- Orientation shown is the entered,Proposed orientation. •(11- ' Wall Overhang -Ornt--ID--Frame Panes NFRC-U=Fadtor SHGC - Area-Depth-Separation-"Irit'Shade Screenirig- ---j 1 SE 2 Vinyl Low-E Double Yes 0.34 0.27 20.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 2 SE 2 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 3 N 3 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 4 NE 4 Vinyl Low-E Double Yes 0.34 0.27 96.0 ft2 9 ft 0 in 1 ft 0 in None Interior 5 5 NE 4 Vinyl Low-E Double Yes • 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 6 NE 4 Vinyl Low-E Double Yes 0.34 0.27 42.7 ft2 1 ft 4 in 1 ft 0 in None Interior 5 • 7 E 5 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 6 ft 4 in 1 ft 0 in None Interior 5 8 NW 6 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 11 ft 0 In None Interior 5 9 NW 6 Vinyl Low-E Double Yes 0.34 0.27 10.0 ft2 1 ft 4 in 11 ft 0 in None Interior 5 10 SW 7 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 11 SW 7 Vinyl Low-E Double Yes 0.34 0.27 25.0 ft2 1 ft 4 in 1 ft 0 in None • Interior 5 I 12 • NW 11 Vinyl Low-E Double Yes 0.34 0.27 45.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 13 NW 11 Vinyl Low-E Double Yes 0.34 0.27 3.6 ft2 1 ft 4 in 1 ft 0 in None .Interior 5 • 14 SW 12 Vinyl Low-E Double Yes 0.34 0.27 20.0 ft2 6 ft 0 in 1 ft 0 in None Interior 5 15 SW 12 Vinyl Low-E Double Yes 0.34 0.27 20.0 ft2 1 ft 4 in 1 ft 0 In None Interior 5 16 SW 12 Vinyl Low-E Double Yes 0.34 0.27 33.3 ft2 6 ft 0 in 1 ft 0 in None Interior 5 5/19/2015 1:19 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang / V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening f 17 NW 6 Vinyl Low-E Double Yes 0.34 0.27 8.0 ft2 1 ft 4 in 11 ft 0 in None Interior 5 I 18 NE 4 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 19 SW 12 Vinyl Low-E Double Yes 0.34 0.27 24.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 20 SE 2 Vinyl Low-E Double Yes 0.34 0.27 8.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 684 ft2 94 ft2 64 ft 10 ft 1 INFILTRATION F SLA CFM 50 ELA EqLA ACH ACH 50. l # Scope Method I 1 Wholehouse Best Guess .0003 3120.1 171.29 322.13 .2844 4.8622 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 42 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:8.2 18 kBtu/hr 2 sys#2 COOLING SYSTEM L._ _ V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts t 1 Central Unit Split SEER:14 42 kBtu/hr 1260 cfm 0.700000 1 sys#1 • f 2 Central Unit Split SEER: 14 18 kBtu/hr 540 cfm 0.7 2 sys#2 HOT WATER SYSTEM f , --• - - ( # System Type SubType Location EFCap Use SetPnt Conservation V 1 Natural Gas Tankless Garage 0.59 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM I' t•FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS I V --Supply-- —Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1 1 Attic 6 516 ft2 Attic 210 ft2 Default Leakage Attic (Default) (Default) 2 Attic • 6 350 ft2 Attic 24Z ft2 Default Leakage Attic (Default) (Default) 2 2 .11 I 5/19/2015 1:19 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 r1 ( 11 ITEMPERATURES Programable Thermostat:N Ceiling Fans: . Cooling Jan Feb Mar Apr May X Jun X Jul X Au X Se Oct Nov Dec Heating X Jan X Feb Mar Apr May Jun Jul Au Sep f t (X (X t t 1 Jun � 1 Jul 1 1 Aug t 1 Sep [X1 Oct OOct [X Nov X Dec Venting [ �Jan Feb X Mar Apr May Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 •7 8. 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 • 78 78 78 .78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 • 78 78 78 • 78 •78 78 78 78 78 78 78 • Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 • • i i I I i I EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 • f 5!19/2015 1:19 PM 9Y it . 1 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 1753 Maritime Oak Dr(lot 101) PERMIT#: Atlantic Beach, FL, MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors= 0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces: gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403:1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the i primary air containment passageways for air distribution systems shall I be considered ducts or plenum chambers, shall be constructed and �. sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters__ .. .._403.4____ .. .. . Heat trap required for vertical,pipe risers. Comply with efficiencies_in _, _. Table 403.4.3.2. Provide switch or clearly marked circuit breaker - .}_ (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 _ — —4-abbess-bid-manual'OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical . ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent N. to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas Nl and heated pools must have vapor-retardant covers or a liquid cover or 1 other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed&attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. \_) Ceilings/knee walls 405.2.1 R-19 space permitting. • 1 I 5/19/2015 1:19 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 • . . I ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD • r j ESTIMATED ENERGY PERFORMANCE INDEX* = 68 The lower the EnergyPerformance Index, the more efficient the home. r ■ 1753 Maritime Oak Dr (lot 101), Atlantic Beach, FL, New(From Plans) 9. Wall Types Insulation Area 1. New construction or existing a.Frame-Wood,Exterior R=19.0 3359.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=19.0 497.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 d.N/A R= ft2 4. Number of Bedrooms 5 Insulation Area 10.Ceiling Types 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 3437.00 ft2 b.N/A R= ft2 6. Conditioned floor area(ft2) 3965 c.N/A R= ft2 7. Windows" Description Area 11..Ducts R ft2 a. U-Factor: .Dbl,U=0.34 520.56 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 516 SHGC: SHGC=0.27 b.Sup: Attic,Ret:Attic,AH:Attic 6 350 S b. Factor: N/A ft2 kBtu/hr Efficiency SHGC: 12.Cooling systems ft2 a.Central Unit 42.0 SEER:14.00 c. U-Factor: N/A b.Central Unit 18.0 SEER:14.00 SHGC: � d. U-Factor: N/A ft2 kBtu/hr Efficiency 13.Heating systems SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.369 ft. b.Electric Heat Pump 18.0 HSPF:8.20 Area Weighted Average SHGC: 0.270 Insulation Area 14.Hot water systems Cap:1 gallons 8. Floor Types a.Slab-On-Grade Edge Insulation R=0.0 2817.00 ft2 a.Natural Gas EF:0.59 b.Floor over Garage R=0.0 590.00 ft2 "b. Conservation features c.other(see details) R= 558.00 ft2 None - - __._._. 15.Credits None ,_ . "' I certify that this home has complied with the Florida Energy Efficiency Code for Building no•OfSBEST,gTr,,` Construction through the above energy saving features which will be installed (or exceeded) �t ti.�.�,�� 4 .4,�: in this home before final inspection. Otherwise, a new EPL Display Card will be completed "v c*,. �t; , based on installed Code compliant features. ""= ', V"-;a, Date: s�G n is a a Builder Signature: /,' ft 44.7 ...` 5r• Address of New Home: City/FL Zip: v *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.corn for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software • • TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA 1 Project Name: CATALINA 3965 Left Builder Name: Toll Brothers Street: 1753 Maritime Oak Dr(lot 101) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and'framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. ;_ ;,,,. ~° °- Exposed earth in unvented crawl spaces_Is covered with Class I""° '""—�' vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening �, to exterior or unconditioned space are sealed. - Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut - to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. • Common wall Air barrier is installed in common wall between dwelling units. \ , HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. \ Fireplace Fireplace walls include an air barrier. `7 EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Manual S Compliance Report Job: McGowall' , p p Date: r,~r:ndii�. ng , . (Rest of House) By: Henditil Ai R w McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 34382 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 2791 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 37173 Btuh Indoor RH: 50% Estimated airflow: 1333 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L Actual airflow: 1333 cfm Sensible capacity: 34382 Btuh 100%of load Latent capacity: 2791 Btuh 100%of load Total capacity: 37173 Btuh 100%of load SHR: 92% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 33050 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L Actual airflow: 1333 cfm Output capacity: 40000 Btuh 121%of load Capacity balance: 27 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1333 cfm Output capacity: 9.7 kW 100%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jun-26 10:17:52 4 wrightsoft Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 A k ..NC\Toll Brothers\3.5 TON-1.5 TON Manual S.rup Calc=MJ8 House faces:SW • Project Summary Job: McGowan Date: Heating&Air i 1 (Rest of House) By: Conditioning�� „ .,..• McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@ mcgowansac.com Web:www.mcgowansac.com Pro'ect Information For: Toll Brothers Fl Notes: Catalina Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 94 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 19 °F Daily range M Relative humidity 50 % Moisture difference 47 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 31608 Btuh Structure 21147 Btuh Ducts 4207 Btuh Ducts 4892 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 35815 Btuh Use manufacturer's data n Rate/swing multiplier 0.99 Infiltration Equipment sensible load 30206 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2826 Btuh Ducts 742 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2965 2965 Equipment latent load 5662 Btuh Volume(ft3) 31451 31451 Air changes/hour 0.25 0.13 Equipment total load 35868 Btuh Equiv.AVF (cfm) 131 70 Req.total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB042 Cond CH14NB042 AHRI ref Coil FB4CNP042 11.5 EER, 14 SEER AHRI ref Efficiency 8.2 HSPF Efficiency Heating input Sensible cooling 28700 Btuh Heating output 40000 Btuh @ 47°F Latent cooling 12300 Btuh Temperature rise 27 °F Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Jun-26 10:46:35 W I'IgIlltsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 4.44 ./. ...300 RES NC\Toll Brothers\CATALINA 3965 Left.rup Calc=MJ8 Front Door faces: S McGowan'%, Project Summary Date: Heating&Air ,�}1 UP STAIRS By: Conditioning 0/. e..,, ,.. • D McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Notes: Catalina Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 94 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 19 °F Daily range M Relative humidity 50 % Moisture difference 47 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12171 Btuh Structure 10321 Btuh Ducts 1549 Btuh Ducts 1888 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13720 Btuh Use manufacturer's data n Rate/swing multiplier 0.99 Infiltration Equipment sensible load 14042 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1657 Btuh Ducts 285 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh l' Area(ft2) 1039 1039 Equipment latent load 1942 Btuh Volume(ft') 12604 12604 Air changes/hour 0.35 0.19 Equipment total load 15984 Btuh Equiv.AVF (cfm) 74 40 Req. total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB018 Cond CH14NB018 AHRI ref Coil FB4CNP018 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17200 Btuh @ 47°F Latent cooling 5340 Btuh Temperature rise 26 °F Total cooling 17800 Btuh Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Jun-26 10:46 .- wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 e ., Page 2 ...300 RES NC\ToII BrotherslCATALINA 3965 Left.rup Calc=MJ8 Front Door faces: S "v "- First Floor 7-1---- - -'-\ - r.--- 12 x t. II 6x, 7" NOOK/KITCHEN GRE'•T ROOM 6 x 12 1.,.,•,:.; W I , ) 7' 14" • • 14x6 14x6 ,.,12 x 6 7" .. Rel 10 x 6 ig 16 x 16 L Riser •• 6 6" 14" ri 144k"L4 0 Sup .6. 3"Fan It 9" Sup Riser Riser 1." D' ING HIS: 8x4 W 8x4 10x10 ® 1 4 x 8 9" 1ox10 HALL 4", Y Y • » CLOSET __I a 12x12 -•" '2xr -- MASTER.BAT, ; 6 x 10 9 6., ■ 4 x 8 I ._6x 10 4" 5" '•' 10x6 STUDY I\` HERS 6" aI 3"Fan FOYER 10" 4x8 3"Fan am 4 PO •E•0' 14 x 14 GARAGE r 4x8 [� r'� WI 2! "TCJ14x14 12" • 6x14 3"Fan Z e BED 2 czrH 4x8 Job #: McGowan's Heating & Air Conditioning Scale: 1 : 106 Performed for: Page 1 Toil Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.17 RSU12270 Ft Phone:904-278-0339 Fax:904-278-0366 2015-Jun-2610:47:01 www.mcgowansac.com jjacobs @mcgowansac.com .Brothers\CATALINA 3965 Left,nip • ,1, 2ND FL Ref Riser f2 18" 18" STORAGE/UNFINISHED Sup 171:/.."' 14 Riser 12" 16" Sup �� 12"@►wMti- Riser 16" 14" WIC 3 6 x 12 ULD 3 8 x 4 4" 12x6 12x12 r, 7' .. 9" 8x4 .. 4„ 8x4 IMF BATH 4„ SINKS 18 x rim 18 3"Fan am, i2" 12x12 rJ 6x12 10" 7" •:. STAIRS; DYER UP 14x6 • E r 8" i 13ED 4 ET-73 -MEI 1 Job #: McGowan's Heating & Air Conditioning Scale: 1 : 106 Performed for: Page 2 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.17 RSU12270 FI Phone:904-278-0339 Fax:904-278-0366 2015-Jun-26 10:47:01 www.mcgowansac.com jjacobs©mcgowansac.com .Brothers\CATALINA 3965 Left.rup System Summary Job: McGowan's. uct S y rY Date: NeaitngBAir + (Rest of House) By: Conrtitioning """""'""" McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O J Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.350/0.150 in H2O 0.350/0.150 in H2O Lowest friction rate 0.125 in/100ft 0.125 in/100ft Actual air flow 1367 cfm 1367 cfm Total effective length(TEL) 399 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH 2 h 1270 48 22 0.144 4.0 Ox 0 VIFx 63.1 180.0 st9 BED 2 h 4833 184 149 0.145 8.0 Ox 0 VIFx 61.1 180.0 st9 DINING r; 1864 83 98 0.179 6.0 Ox 0 VIFx 35.5 160.0 st5 FOYER h 2473 94 56 0.162 6.0 Ox 0 VIFx 51.0 165.0 sty GREAT ROOM c 3312 138 174 0.173 8.0 Ox 0 VIFx 37.4 165.0 st5 GREAT ROOM-A c 3312 138 174 0.173 8.0 Ox 0 VIFx 37.9 165.0 st5 HALL-A c 917 40 48 0.169 5.0 Ox 0 VIFx 36.6 170.0 st7 HERS h 415 16 10 0.165 4.0 Ox 0 VIFx 37.6 175.0 st7 HIS h 540 21 7 0.134 4.0 Ox 0 VIFx 56.6 205.0 st8 LAUNDRY c 6 0 0 0.179 4.0 Ox 0 VIFx 31.0 165.0 st7 MASTER BATH h 2467 94 80 0.140 6.0 Ox 0 VIFx 44.5 205.0 st8 MASTER BED h 2908 111 103 0.127 7.0 Ox 0 VIFx 75.2 200.0 st6 MASTER BED-A h 2908 111 103 0.129 7.0 Ox 0 VIFx 71.2 200.0 st6 NOOK/KITCHEN c 1999 68 105 0.125 7.0 Ox 0 VIFx 79.3 200.0 st6 NOOK/KITCHEN-A c 1999 68 105 0.128 7.0 Ox 0 VIFx 74.1 200.0 st6 POWDER h 253 10 7 0.140 4.0 Ox 0 VIFx 64.8 185.0 st9 STUDY h 3480 133 116 0.165 7.0 Ox 0 VIFx 46.6 165.0 st5 We c 4 0 0 0.141 4.0 Ox 0 VIFx 48.5 200.0 st8 WIC 2 h 252 10 8 0.146 4.0 Ox 0 VIFx 59.4 180.0 st9 2015-Jun-26 10:46:35 ,. wrlghtsoft" Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 AC ...300 RES NC\Toll Brothers\CATALINA 3965 Left.rup Calc=MJ8 Front Door faces: S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st8 Peak AVF 115 88 0.134 430 7.0 0 x 0 ViniFlx st7 st7 Peak AVF 171 146 0.134 386 9.0 0 x 0 VinIFIx st3 st2 Peak AVF 944 1035 0.125 741 16.0 0 x 0 VinIFIx st6 Peak AVF 357 417 0.125 390 14.0 0 x 0 VinIFIx st5 st5 Peak AVF 944 1035 0.125 741 16.0 0 x 0 ViniFlx st2 st3 Peak AVF 423 332 0.134 538 12.0 0 x 0 VinIFIx st9 Peak AVF 252 186 0.140 462 10.0 0 x 0 VinIFIx st3 Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 378 424 119.6 0.125 397 14.0 Ox 0 VIFx rt2 rb11 Ox 0 479 359 92.7 0.162 1085 9.0 Ox 0 VIFx rt2 rb10 Ox 0 509 584 114.0 0.131 546 14.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk d rt2 Peak AVF 1367 1367 0.125 774 18.0 0 x 0 VinIFIx 2015-Jun-26 10:46:35 �' W rightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 ACC,A . 300 RES NC\Toll Brothers\CATALINA 3965 Left.rup Calc=MJ8 Front Door faces: S 1VIcGowari's. Duct System Summary Date: F?otir7g&Ai. i l? UP STAIRS By Conditioning ; McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply I return available pressure 0.300/0.200 in H2O 0.300/0.200 in H2O Lowest friction rate 0.148 in/100ft 0.148 in/100ft Actual air flow 593 cfm 593 cfm Total effective length (TEL) 339 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH h 399 17 17 0.187 4.0 Ox 0 VIFx 30.6 130.0 st1 BED 3 c 2402 89 117 0.191 7.0 Ox 0 VIFx 27.3 130.0 st1 BED 4 c 2864 118 139 0.148 8.0 Ox 0 VIFx 38.4 165.0 st4 LOFT h 2762 119 104 0.155 7.0 Ox 0 VIFx 33.6 160.0 st4 LOFT-A h 2762 119 104 0.153 7.0 Ox 0 VIFx 36.6 160.0 st4 LOFT-B h 2762 119 104 0.199 7.0 Ox 0 VIFx 20.9 130.0 st1 SINKS c 76 2 4 0.200 4.0 Ox 0 VIFx 25.1 125.0 st1 wWC 3 h 185 8 5 0.199 4.0 Ox 0 VIFx 21.0 130.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 357 347 0.148 455 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 593 593 0.148 555 14.0 0 x 0 ViniFlx 2015-Jun-26 10:46:35 a Wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 3 ACCI1 . 300 RES NC1Toll Brothers\CATALINA 3965 Left.rup Cale=MJ8 Front Door faces: S Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox 0 239 207 99.0 0.202 438 10.0 Ox 0 VIFx ill rb3 Ox 0 114 139 90.0 0.222 315 9.0 Ox 0 VIFx ill rb6 Ox 0 240 247 135.5 0.148 558 9.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rtl Peak AVF 593 593 0.148 555 14.0 0 x 0 VinIFIx 1 li iii 2015-Jun-26 10:46:35 .� W rightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 4 ACGk ...300 RES NC\Toll Brothers\CATALINA 3965 Left.rup Calc=MJ8 Front Door faces: S Manual S Compliance Report Job: I`�CGOWSIi'S P p Date: .,aftfig$Air i B Conditioning 7N '` UP By: McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 14930 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.2°F Latent gain: 1722 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 16652 Btuh Indoor RH: 50% Estimated airflow: 593 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A+FB4CNP018L Actual airflow: 593 cfm Sensible capacity: 14930 Btuh 100%of load Latent capacity: 1722 Btuh 100%of load Total capacity: 16652 Btuh 100%of load SHR: 90% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 11541 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A+FB4CNP018L Actual airflow: 593 cfm Output capacity: 17800 Btuh 154%of load Capacity balance: 23 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 593 cfm Output capacity: 3.3 kW 97%of load Temp. rise: 17 °F The above equipment was selected in accordance with ACCA Manual S. -l�" 2015-Jun-26 10:17:52 f wrughtsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 ACCA ...NC\Toll Brothers13.5 TON-1.5 TON Manual S.rup Calc=MJ8 House faces:SW