1390 BEGONIA ST - ENERGY SHEETS FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: R0515186 Builder Name: /` % w 1'"r"o'T
Z/v v`--
Street: 1390 Begonia St Permit Office: City of Atlantic Beach
City,State,Zip: Atlantic Beach,FL, Permit Number:
Owner: Jurisdiction: 261100
Design Location: FL,Jacksonville
1. New construction or existing New(From Plans) 9. Wall Types(1950.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a. Frame-Wood,Exterior R=13.0 1647.00 ft2
b. Frame-Wood,Adjacent R=11.0 303.00 ft2
3. Number of units, if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 3 d. N/A R= ft2
10.Ceiling Types (1822.0 sqft.) Insulation Area
5. Is this a worst case? No a. Under Attic(Vented) R=38.0 1822.00 ft2
6. Conditioned floor area above grade(ft2) 1822 b. N/A R= ft2
ft2
Conditioned floor area below grade(ft2) 0 c N/A R R ft2
11. Ducts
7. Windows(160.2 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Garage 6 225
a. U-Factor: Dbl, U=0.52 160.20 ft2
SHGC: SHGC=0.30
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 33.6 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Heat Pump 34.0 HSPF:8.00
SHGC:
Area Weighted Average Overhang Depth: 4.464 ft.
Area Weighted Average SHGC: 0.300 14. Hot water systems
a. Electric Cap:80 gallons
8. Floor Types (1822.0 sqft.) Insulation Area EF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1822.00 ft2 b. Conservation features
b. N/A R= ft2 None
c. N/A R= ft2 15.Credits None
Total Proposed Modified Loads: 26.51
Glass/Floor Area: 0.088 PASS
Total Standard Reference Loads: 40.78
I hereby certify that the plans and specifications covered by Review of the plans and �,-•O�IHE STgT
this calculation are in compliance with the Florida Energy specifications covered by this /�ti ,i i ; FO
Code. J(4"." /� calculation indicates compliance `� ,,, '= �
21(3Z ea, with the Florida Energy Code. i ',.,I ,, ..• •.,;,04-"„ O�
8 Q _1r •, "
PREPARED BY: . _ Before construction is completed • w -_ :- " _
DATE: 08-14-15 this building will be inspected for 0 "� 1
compliance with Section 553.908 a.
I hereby certify that this building, as desig -., is in compliance Florida Statutes. '; f °
with the Florida Energy Code. �.. Co WE ...."
OWNER/AGENT• BUILDING OFFICIAL:
DATE: -- /4/-/ 5 - DATE: . g
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
G0Q
OF
8/14/2015 2:48 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7
PROJECT
Title: R0515186 Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1822 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 1390 Begonia St
Permit Office: City of Atlantic Beach Cross Ventilation: No County: Duval
Jurisdiction: 261100 Whole House Fan: No City,State,Zip: Atlantic Beach,
Family Type: Single-family
FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1822 16398
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Master Bedroom 235 2115 No 2 1 1 Yes Yes Yes
2 MWic 2 76 684 No 0 1 Yes Yes Yes
3 MWic 1 20 180 No 0 1 No Yes Yes
4 MBath 88 796 No 0 1 Yes Yes Yes
5 WC 18 162 No 0 1 No Yes Yes
6 Pwdr Rm 28 252 No 0 1 No Yes Yes
7 Laundry 66 594 No 0 1 Yes Yes Yes
8 Kitchen 233 2097 Yes 0 1 Yes Yes Yes
9 Family Rm 392 3528 No 0 1 Yes Yes Yes
10 Bedroom 3 185 1665 No 1 1 1 Yes Yes Yes
11 Bath 55 495 No 0 1 Yes Yes Yes
12 Hall 40 360 No 0 1 No Yes Yes
13 Bedroom 2 173 1557 No 1 1 1 Yes Yes Yes
14 Foyer 69 621 No 0 1 Yes Yes Yes
15 Dining Rm 144 1296 No 0 1 Yes Yes Yes
FLOORS
✓ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Master Bedroom 29 ft 0 235 ft2 _ 0 0 1
2 Slab-On-Grade Edge Insulatio MWic 2 18 ft 0 76 ft2 ____ 0 0 1
3 Slab-On-Grade Edge Insulatio MWic 1 1 ft 0 20 ft2 ____ 0 0 1
8/14/2015 2:48 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7
FLOORS
✓ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
4 Slab-On-Grade Edge Insulatio MBath 14.3 ft 0 88 ft2 ____ 0 0 1
5 Slab-On-Grade Edge Insulatio WC 1 ft 0 18 ft2 __•_ 0 0 1
6 Slab-On-Grade Edge Insulatio Pwdr Rm 1 ft 0 28 ft2 ___ 0 0 1
7 Slab-On-Grade Edge Insulatio Laundry 10.3 ft 0 66 ft2 ___ 0 0 1
8 Slab-On-Grade Edge Insulatio Kitchen 1 ft 0 233 ft2 �_ 0 0 1
9 Slab-On-Grade Edge Insulatio Family Rm 22 ft 0 392 ft2 ___ 0 0 1
10SIab-On-Grade Edge Insulatio Bedroom 3 27.3 ft 0 185 ft2 ____ 0 0 1
11SIab-On-Grade Edge Insulatio Bath 9 ft 0 55 ft2 ___ 0 0 1
12SIab-On-Grade Edge Insulatio Hall 1 ft 0 40 ft2 ____ 0 0 1
13SIab-On-Grade Edge Insulatio Bedroom 2 31 ft 0 173 ft2 ___ 0 0 1
14SIab-On-Grade Edge Insulatio Foyer 6.7 ft 0 69 ft2 ____ 0 0 1
15SIab-On-Grade Edge Insulatio Dining Rm 15.3 ft 0 144 ft2 _ 0 0 1
ROOF
V/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1974 ft2 0 ft2 Medium 0.65 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1822 ft2 N N
CEILING
# Ceiling Type - Space R-Value Area Framing Frac Truss Type
1 Under Attic(Vented) Master Bedroom 38 235 ft2 0.1 Wood
2 Under Attic(Vented) MWic 2 38 76 ft2 0.1 Wood
3 Under Attic(Vented) MWic 1 38 20 ft2 0.1 Wood
4 Under Attic(Vented) MBath 38 88 ft2 0.1 Wood
5 Under Attic(Vented) WC 38 18 ft2 0.1 Wood
6 Under Attic(Vented) Pwdr Rm 38 28 ft2 0.1 Wood
7 Under Attic(Vented) Laundry 38 66 ft2 0.1 Wood
8 Under Attic(Vented) Kitchen 38 233 ft2 0.1 Wood
9 Under Attic(Vented) Family Rm 38 392 ft2 0.1 Wood
10 Under Attic(Vented) Bedroom 3 38 185 ft2 0.1 Wood
11 Under Attic(Vented) Bath 38 55 ft2 0.1 Wood
12 Under Attic(Vented) Hall 38 40 ft2 0.1 Wood
13 Under Attic(Vented) Bedroom 2 38 173 ft2 0.1 Wood
14 Under Attic(Vented) Foyer 38 69 ft2 0.1 Wood
15 Under Attic(Vented) Dining Rm 38 144 ft2 0.1 Wood
8/14/2015 2:48 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
Omt To W 1I tyre Space R-Vab� __Ft In Ft In - Area __R-Va1ii Fraction _Absor_ Grade%
1 E Exterior Frame-Wood Master Bedro 13 13 4 9 0 120.0 ft2 0 0.25 0.3 0
2 S Exterior Frame-Wood Master Bedro 13 15 8 9 0 141.0 ft2 0 0.25 0.3 0
3 S Exterior Frame-Wood MWic 2 13 6 8 9 0 60.0 ft2 0 0.25 0.3 0
_4 W Exterior Frame-Wood MWic 2 13 11 4 9 0 102.0 ft2 0 0.25 0.3 0
5 W Exterior Frame-Wood MBath 13 14 4 9 0 129.0 ft2 0 0.25 0.3 0
6 W Exterior Frame-Wood Laundry 13 10 4 9 0 93.0 ft2 0 0.25 0.3 0
7 E Exterior Frame-Wood Family Rm 13 2 0 9 0 18.0 ft2 0 0.25 0.3 0
8 S Exterior Frame-Wood Family Rm 13 20 0 9 0 180.0 ft2 0 0.25 0.3 0
9 E Exterior Frame-Wood Bedroom 3 13 12 4 9 0 111.0 ft2 0 0.25 0.3 0
10 S Exterior Frame-Wood Bedroom 3 13 15 0 9 0 135.0 ft2 0 0.25 0.3 0
11 N Exterior Frame-Wood Bath 13 2 8 9 0 24.0 ft2 0 0.25 0.3 0
12 E Exterior Frame-Wood Bath 13 6 4 9 0 57.0 ft2 0 0.25 0.3 0
13 N Exterior Frame-Wood Bedroom 2 13 15 0 9 0 135.0 ft2 0 0.25 0.3 0
14 E Exterior Frame-Wood Bedroom 2 13 12 4 9 0 111.0 ft2 0 0.25 0.3 0
15 W Exterior Frame-Wood Bedroom 2 13 3 8 9 0 33.0 ft2 0 0.25 0.3 0
16 N Exterior Frame-Wood Foyer 13 6 8 9 0 60.0 ft2 0 0.25 0.3 0
17 N Exterior Frame-Wood Dining Rm 13 11 8 9 0 105.0 ft2 0 0.25 0.3 0
_18 E Exterior Frame-Wood Dining Rm 13 3 8 9 0 33.0 ft2 0 0.25 0.3 0
19 W Garage Frame-Wood Dining Rm 11 12 4 9 111.0 ft2 0.23 0.01 0
_20 N Garage Frame-Wood Kitchen 11 13 8 9 123.0 ft2 0.23 0.01 0
21 N Garage Frame-Wood Laundry 11 7 8 9 69.0 ft2 0.23 0.01 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Insulated Foyer None .35 3 6 8 20 ft2
2 N Insulated Kitchen None .46 3 7 21 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC _ Area D epth Separation Int Shade Screening
1 S 2 Metal Low-E Double Yes 0.52 0.3 30.0 ft2 1 ft 4 in 1 ft 7 in Drapes/blinds Exterior 5
2 S 8 Metal Low-E Double Yes 0.52 0.3 40.2 ft2 9 ft 4 in 1 ft 4 in Drapes/blinds None
3 S 8 Metal Low-E Double Yes 0.52 0.3 30.0 ft2 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5
4 S 10 Metal Low-E Double Yes 0.52 0.3 15.0 ft2 1 ft 4 in 5 ft 1 in Drapes/blinds Exterior 5
5 N 13 Metal Low-E Double Yes 0.52 0.3 15.0 ft2 1 ft 4 in 1 ft 7 in Drapes/blinds Exterior 5
6 N 17 Metal Low-E Double Yes 0.52 0.3 30.0 ft2 1 ft 4 in 1 ft 7 in Drapes/blinds Exterior 5
8/14/2015 2:48 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7
I
V GARAGE
_ V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height
Exposed Wall Insulation
1 419.61 ft2
0 ft2 64 ft 9 ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgIA ACH ACH 50
1 Wholehouse Best Guess .0005 2389.6 131.18 246.71 .385
8.7413
HEATING SYSTEM
'✓ # System Type Subtype Efficiency Capacity B lock Ducts
1 Electric Heat Pump None HSPF:8 34 kBtu/hr
1 sys#1
COOLING SYSTEM
V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 14 33.6 kBtu/hr cfm 0.73 1 sys#1
HOT WATER SYSTEM
V # System Type SubType Location EF Cap Use _ SetPnt Conservation
1 Electric None Garage 0.97 80 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
VFSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— —Return— Alr CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 225 ft2 Attic 150 ft2 Default Leakage Garage (Default) (Default) 1 1
8/14/2015 2:48 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7
' TEMPERATURES
Programable Thermostat:N Ceiling Fans:
Coolin - Jan Feb Mar A r Ma Jun Jul X Au X Se Oct Nov Dec
Heating X Jan [X�Feb [Xt Mar [ i Apr f 1 May [ Jun [ Jul 4Aug f 'Sep f 1 Oct [XI Nov X)Dec
Venting Jan [ Feb [X Mar [X r ( Ma Jun Jul [ 'Aug [ Se [X Oct [X Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
8/14/2015 2:48 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7
1
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 1390 Begonia St PERMIT#:
Atlantic Beach, FL,
MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and
controls cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental t./
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker 1 i
(electric) or shutoff(gas). Circulating system pipes insulated to = R-2 (/
+ accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent (/
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or /'
other means proven to reduce heat loss except if 70% of heat from V
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment occasion cooling or heating capacity requires separate system or 1 /
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
8/14/2015 2:48 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 7 of 7
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
1 ,
ESTIMATED ENERGY PERFORMANCE INDEX* = 65
The lower the EnergyPerformance Index,the more efficient the home.
1390 Begonia St, Atlantic Beach, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame Wood,Exterior R=13.0 1647.00 ft2
b.Frame-Wood,Adjacent R=11.0 303.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=38.0 1822.00 ft2
6. Conditioned floor area(ft2) 1822 b.N/A R= ft2
7. Windows" Description Area c.N/A R= ft2
a. U-Factor: Dbl,U=0.52 160.20 ft2 11. Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:Garage 6 225
SHGC: SHGC=0.30
b. U-Factor: N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 33.6 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.0 HSPF:8.00
Area Weighted Average Overhang Depth: 4.464 ft.
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:80 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1822.00 ft 2 EF:0.97
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building . :SHE ST
Construction through the above energy saving features which will be installed (or exceeded) 04. �TF''•;
in this home before final inspection. Otherwise - new EPL Display Card will be completed y��,,�`'%, -jr
=r ��',
based on installed Code compliant feat - :1, ,,,,,, "h. • '..3" �p`,•
Builder Signature: ' Date: .9--/11`IS- :.V a_ :>;
Address of New Home: 1 Gt p 5 i-\.(1, 5 3--- City/FL Zip:#44,144,4( bA '.■4, " fi°° `9O
3zz33
f
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
i
N
HVAC Layout
10x6
48 cfm
5" ..
14$14
10 x 6 197'cfm
136 cfm "
-7.—_— ?---- _e----Y---.11- .„,‘\_ - •,..•0711 _
=No-- . LEI 0
10x6 10x10 k i
100 cfm / 1111 145 cfrn '' x 4
7'' - \ 7" iii i'* ./ ,cfm 0
10x10
10 x10
`
cfm
111 cm 111
"
Xf 7" • � '
a -
o
10 O
!a
dri 1i1� 10x6
_ I 75 cfm
10 x 10 i_4.� 4 �,�� 145 N ` 6. ii 0
9' T
• 7" 24x14
8x4 1 fl 23 cfm ■ 923 cfm /`— ■4" �III
\ 12" w•A Co
12x12 J 30cfm 76x6
10" 4" 76 cfm
6'
10x6 /
100 cfm
7"
L.
Job#: R0515186 Kevin Martin Scale: 1 : 104
Performed by JT for: Page 1
Right-Suite®Universal 2015
1390 Begonia St 15.0.19 RSU07440
Atlantic Beach,FL Phone: 954235 8307 2015-Aug-14 15:10:12
..515186-Begonia St\R0515186.rup
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 1390 Begonia St PERMIT#:
Atlantic Beach, FL,
MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and
controls cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker q /
(electric) or shutoff(gas). Circulating system pipes insulated to = R-2
+accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas. (/
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or r /
other means proven to reduce heat loss except if 70% of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls , 405.2.1 R-19 space permitting.
5/21/2015 10:40 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 7 of 7
•
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
1 ,
ESTIMATED ENERGY PERFORMANCE INDEX* = 65
The lower the EnergyPerformance Index, the more efficient the home.
o o
1390 Begonia St, Atlantic Beach, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a. Frame-Wood.Exterior R=13.0 1647.00 ft2
b. Frame-Wood,Adjacent R=11.0 303.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d. N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1822.00 ft2
6. Conditioned floor area(ft2) 1822 b.N/A R= ft2
7. Windows'" Description Area c. N/A R= ft2
a. U-Factor: Dbl,U=0.52 160.20 ft2 11. Ducts R ft2
a.Sup:Attic, Ret:Attic,AH:Garage 6 225
SHGC: SHGC=0.30
b. U-Factor: N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 33.6 SEER:14.00
SHGC:
d. U-Factor: N/A ft2
13. Heating systems kBtu/hr Efficiency
SHGC:
a. Electric Heat Pump 34.0 HSPF:8.00
Area Weighted Average Overhang Depth: 4.464 ft.
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14. Hot water systems
ft2 a.Electric Cap:80 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1822.00 ft EF:0.97
b. N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building .04-01-1E sr 2.' -5.
Construction through the above energy saving features which will be installed (or exceeded) "ti° y = _ ■oa
in this home before final inspection. Oibewise, a new EPL Display Card will be completed ` ��',,,, . ,{,
based on installed Code compliant featur -- . E.tr,,,,,, rc ' :oot„-:0 t
d -2q--/5 ,� :o
Builder Signatur . Date: �.c�*� a__ .
Address of New Home: 1362 0 L5 ,,�q 5 L. City/FL Zip: Q>/-f..y�n,I,L, j t -�` �/
.* DW6
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
-�+ wri g htsoft Manual S Compliance Report Job: R0515186
Date: 20 MAY 2015
Entire House By: JT
Mr Kevin Martin
FL
Project Information
For:
1390 Begonia St,Atlantic Beach, FL
Cooling Equipment
Design Conditions
Outdoor design DB: 92.7°F Sensible gain: 24279 Btuh Entering coil DB: 78.5°F
Outdoor design WB: 77.1°F Latent gain: 6769 Btuh Entering coil WB: 64.2°F
Indoor design DB: 75.0°F Total gain: 31048 Btuh
Indoor RH: 50% Estimated airflow. 1120 cfm
Manufacturer's Performance Data atActual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier or Eqv. Model: CH14NA036****A+FB4CNP036
Actual airflow 1120 cfm
Sensible capacity: 24528 Btuh 101% of load
Latent capacity: 9072 Btuh 134% of load
Total capacity: 33600 Btuh 108% of load SHR: 73%
Heating Equipment
Design Conditions
Outdoor design DB: 32.5°F Heat loss: 27959 Btuh Entering coil DB: 67.5°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data atActual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier or Eqv. Model: CH14NA036****A+FB4CNP036
Actual airflow. 672 cfm
Output capacity: 34000 Btuh 122% of load Capacity balance: 29 "'F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow 672 cfm
Output capacity: 10.0 kW 122% of load Temp. rise: 46 °F
The above equipment was selected in accordance with ACCA Manual S.
2015-May-21 104729
wrightsoft Right-Suite®Universal 2015 15.0.15 RSU20773 Page 1
ACCk ...C1aWorkFile'x0515186-Begonia StR0515186.rup CaIc=MJB Front Door faces: N
Project Summary Job: R0515186
W ri9htSOft Date: 20 MAY 2015
Entire House By: JT
Mr Kevin Martin
FL
Project Information
For
1390 Begonia St, Atlantic Beach, FL
Notes: Load Calculation was obtained from an electronic copy of CAD drawing.
Desi• n Information
Weather: Jacksonville Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 33 °F Outside db 93 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 18 °F
Daily range M
Relative humidity 50 ok
Moisture difference 51 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 22550 Btuh Structure 16223 Btuh
Ducts 5409 Btuh Ducts 7545 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 512 Btuh
Piping 0 Btuh
Equipment load 27959 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 24279 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
I Construction quality Average
Fireplaces 0 Structure 4989 Btuh
Ducts 1780 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft2) 1822 1822 Equipment latent load 6769 Btuh
Volume (ft3) 16398 16398
Air changes/hour 0.38 0.20 Equipment total load 31048 Btuh
Equiv. AVF (cfm) 104 55 Req. total capacity at 0.73 SHR 2.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier or Eqv. Make Carrier or Eqv.
Trade Split HP Trade Split HP
Model CH14NA036****A Cond C H1 4NA036****A
AHRI ref 6803064 Coil FB4CNP036
AHRI ref 6803064
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 24528 Btuh
Heating output 34000 Btuh @ 47°F Latent cooling 9072 Btuh
Temperature rise 46 °F Total cooling 33600 Btuh
Actual air flow 672 cfm Actual air flow 1120 cfm
Air flow factor 0.024 cfm/Btuh Air flow factor 0.047 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.78
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2015-May-21 10:47:29
, W rigntSOft' Right-Suite®Universal 2015 15.0.15 RSU20773 Page 1
ACCP. ...CoWork File\R0515186-Begonia SB 0515186.rup Catc=MJ8 Front Door faces. N
+1+ w.rightsoft Right-J® Worksheet Job: R0515186
Entire House Date: 20 MAY 2015
By: JT
Mr Kevin Martin
FL
1 Room name Entire House Master Bedroom
2 Exposed wall 183.0 ft 29.0 ft
3 Room height 9.0 ft 9.0 ft heat/cool
4 Room dimensions 15.7 x 15.0 ft
5 Room area 1822.0 ft' 235.0 ft'
Ty Construction U-value Or I HTM Area (ft') Load Area (ft') Load
number (Btuhlft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 3.41 2.29 324 259 883 594 0 0 0 0
4A5-20b 0.520 n 19.50 12.53 45 0 878 564 0 0 0 0
11NO 0.350 n 13.13 10.57 20 20 264 212 0 0 0 0
. W 12C-Osw 0.091 e 3.41 2.29 450 450 1536 1032 120 120 409 275
11 W 12C-Osw 0.091 s 3.41 2.29 516 401 1368 919 141 111 379 255
-G 10D-b 0.520 s 19.50 9.75 40 40 784 392 0 0 0 0
G 4A5-2ob 0.520 s 19.50 12.53 30 30 585 376 30 30 585 376
`G 4A5-2ob 0.520 s 19.50 13.85 15 6 293 208 0 0 0 0
G 4A5-2ob 0.520 s 19.50 12.53 30 30 585 376 0 0 0 0
W 12C-Osw 0.091 w 3.41 2.29 357 357 1218 819 0 0 0 0
9 12B-Osw 0.097 - 3.64 1.69 307 286 1039 482 0 0 0 0
I D 11NO 0.350 n 13.13 10.57 21 21 276 222 0 0 0 0
C 16B-38ad 0.026 - 0.98 1.40 1822 1822 1776 2544 235 235 229 328
F 22A-cpl 0.989 - 37.09 0.00 1822 183 6787 0 235 29 1076 0
1
6 c)AED Excursion 0 36
Envelope loss/gain 18271 8740 2678 1270
12 a) Infiltration 4279 1063 678 168
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 4 920 2 460
Appliances/other 5500 0
Subtotal(lines 6 to 13) 22550 16223 3356 1898
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 22550 16223 3356 1898
15 Duct loads 24% 47% 5409 7545 24% 47% 805 883
Total room load 27959 23767 4161 2781
Air required(cfm) 672 1120 100 131
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
W rightsof[• 2015-May-21 10:47:29
Rig ht-Suitee Universal 2015 15.0.15 RSU20773 Page 1
...ClaWork File1R0515186-Begonia S#R0515186.rup Caic=MJ8 Front Door fa ms N
4 varightsoft Right-J® Worksheet Job: R0515186
Entire House Date: 20 MAY 2015
By: JT
Mr Kevin Martin
FL
1 Room name MWic 2 MWic 1
2 Exposed wall 18.0 ft 0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 6.7 x 11.3 ft 5.3 x 3.7 ft
5 Room area 75.6 ft' 19.6 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load
number (Btuh/ft'`F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 3.41 2.29 0 0
. -G 4A5-2ob 0.520 n 19.50 12.53 0 0
. -D 11NO 0.350 n 13.13 10.57 0 0
. W 12C-Osw 0.091 e 3.41 2.29 0 0
11 W 12C-Osw 0.091 s 3.41 2.29 6 6 205 138
-G 10D-b 0.520 s 19.50 9.75 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0
-G 4A5-2ob 0.520 s 19.50 13.85 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0
W 12C-Osw 0.091 w 3.41 2.29 10 10 348 234
Pf I 12B-Osw 0.097 - 3.64 1.69 0 0
D 11NO 0.350 n 13.13 10.57 0 0
C 16B-38ad 0.026 - 0.98 1.40 7 7 74 105 2 2 1 2
F 22A-cpl 0.989 - 37.09 0.00 7 1 668 0 2
6 c)AED eccursion -4 0
Envelope loss/gain 1294 473 19 27
12 a) Infiltration 421 105 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1715 578 19 27
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1715 578 19 27
15 Duct loads 24% 47% 411 269 24% 47% 5 13
Total room load 2126 847 24 40
Air required(cfm) 51 40 1 2
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
± wrightsoTt 2015-May-2110:47:29
Right-Suite0 Universal 2015 15.0.15 RSU20773 Page 2
..C\awork FileV20515186-Begonia St1R0515186.rup Cale=MJ8 Front Door Earns• N
4 wrightsoft Right-J® Worksheet Job: R0515186
Entire House Date: 20 MAY 2015
By: JT
Mr Kevin Martin
FL
1 Room name MBath WC
2 Exposed wall 14.3 ft 0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 1.0 x 88.4 ft 5.3 x 3.3 ft
5 Room area 88.4 ft' 17.8 ft'
Ty Construction U-value Or HTM Area (ft') I Load Area (ft') Load
number (Btuh/ft'-°F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 3.41 2.29 0 0 0 0 0 0
. -G 4A5-2ob 0.520 n 19.50 12.53 0 0 0 0 0 0
. -D 11N0 0.350 n 13.13 10.57 0 0 0 0 0 0
. W 12C-Osw 0.091 e 3.41 2.29 0 0 0 0 0 0
11 VV 12C-Osw 0.091 s 3.41 2.29 0 0 0 0 0 0
-G 10D-b 0.520 s 19.50 9.75 0 0 0 0 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0 0 0 0 0
-G 4A5-2ob 0.520 s 19.50 13.85 0 0 0 0 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0 0 0 0 0
W 12C-Osw 0.091 w 3.41 2.29 129 129 44 296 0 0 0
R L-D12B-Osw 0.097 - 3.64 1.69 0 0 0 0 0 0
11NO 0.350 n 13.13 10.57 0 0 0 0 0 0
C 16B-38ad 0.026 - 0.98 1.40 88 88 86 123 18 18 17 2
F 22A-cpl 0.989 - 37.09 0.00 88 14 532 0 18 0 0
6 c)AED excursion -3 0
Envelope loss/gain 1058 416 17 25
12 a) Infiltration 335 83 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1393 499 17 25
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1393 499 17 25
15 Duct loads 24% 47% 334 232 24% 47% 4 11
Total room load 1727 732 21 36
Air required(cfm) 42 34 1 2
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
_ wr- f7tsOft. 2015-May-21104729
9 Right-Suite®Universal 2015 15.0.15 RSU20773 Page 3
. CCU ...C\aW ork FIe\R0515186-Begonia St R0515186.rup Calc=MJ8 Front Door faces:N g
f if wrightsoft Right-J® Worksheet Job: R0515186
Entire House Date: 20 MAY 2015
By: JT
Mr Kevin Martin
FL
1 Room name Pwdr Rm Laundry
2 Exposed wall 0 ft 10.3 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 5.3 x 5.3 ft 1.0 x 65.8 11
5 Room area 28.4 ft' 65.8 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load
number (Btuh/ft'-'F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 3.41 2.29
4A5-2ob 0.520 n 19.50 12.53
11NO 0.350 n 13.13 10.57
. W 12C-Osw 0.091 e 3.41 2.29
11 W 12C-Osw 0.091 s 3.41 2.29
-G 10D-b 0.520 s 19.50 9.75
-G 4A5-2ob 0.520 s 19.50 12.53
-G 4A5-2ob 0.520 s 19.50 13.85
I-G 4A5-2ob 0.520 s 19.50 12.53
W 12C-Osw 0.091 w 3.41 2.29 9 9 31 21
R 12B-Osw 0.097 - 3.64 1.69 7 7 264 12
I D 11NO 0.350 n 1113 10.57 0
C 16B-38ad 0.026 - 0.98 1.40 2 2 2 4 66 66 64 9
F 22A-cp1 0.989 - 37.09 0.00 2 66 10 383
1
I
6 c)AED eccursion 0 -6
Envelope loss/gain 28 39 1029 422
12 a) Infiltration 0 0 242 60
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 500
Subtotal(lines 6 to 13) 28 39 1271 982
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 28 39 1271 982
15 Duct loads 24% 47% 7 18 24% 47% 305 456
Total room load 34 58 1576 1438
Air required(cfm) 1 3 38 68
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft Right-Suite®Universal 2015 15.0.15 RSU20773 2015-May-21 10:47:29
...CtaWork File1R0515186-Begonia SttR0515186.rup Calc=MJ8 Front Door faces:N Page
4 wrightsoft Rig ht-J® Worksheet Job: R0515186
Entire House Date: 20 MAY 2015
By: JT
Mr Kevin Martin
FL
1 Room name Kitchen Family Rm
2 Exposed wall 0 ft 22.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 1.0 x 233.4 ft 1.0 x 391.3 ft
5 Room area 233.4 ft' 391.3 ft'
Ty Construction I U-value Or I HTM Area (ft') Load Area (ft') Load
number 1 (Btuh/ft'"F) (Btuhrft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-0sw 0.091 n 3.41 2.29 0 0 0 0 0
4A5-2ob 0.520 n 19.50 12.53 0 0 0 0 0
11NO 0.350 n 13.13 10.57 0 0 0 0 0
. W 12C-Osw 0.091 e 3.41 2.29 0 0 18 1 61 41
11 W 12C-Osw 0.091 s 3.41 2.29 0 0 180 11 375 252
G 100-b 0.520 s 19.50 9.75 0 0 40 4 784 392
G 4A5-2ob 0.520 s 19.50 12.53 0 0 0 0 0
IG 4A5-2ob 0.520 s 19.50 13.85 0 0 0 0 0
L_G 4A5-2ob 0.520 s 19.50 12.53 0 0 30 30 585 376
W 12C-Osw 0.091 w 3.41 2.29 0 0 0 0 0 0
pi I 12B-Osw 0.097 - 3.64 1.69 123 102 371 17 0 0 0 0
D 11NO 0.350 n 13.13 10.57 21 21 276 222 0 0 0 0
C 16B-38ad 0.026 - 0.98 1.40 233 233 228 326 391 391 382 546
F 22A-cpl 0.989 - 37.09 0.00 233 0 0 0 391 22 816 0
6 c)AED excursion -27 -21
Envelope loss/gain 874 693 3002 1587
12 a) Infiltration 0 0 514 128
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 3500 1500
Subtotal(lines 6 to 13) 874 4193 3517 3215
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 874 4193 3517 3215
15 Duct loads 24% 47% 210 1950 24% 47% 844 1495
Total room load 1084 6143 4360 4710
Air required(cfm) 26 289 105 222
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
+1-1- wrightsoft Right-Suite®Universal 2015 15.0.15 RSU20773 2015-May-211Pa7e5
ACC'A ...C1aWorkFiteIR0515186-Begonia StIR0515186.rup Cale=MJ8 Front Door faces:N 9
III wrightsoft Right-J® Worksheet Job: R0515186
Entire House Date: 20 MAY 2015
By: JT
Mr Kevin Martin
FL
1 Room name Bedroom 3 Bath
2 Exposed wall 27.3 ft 9.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 15.0 x 12.3 ft 8.7 x 6.3 ft
5 Room area 185.0 ft' 54.9 ft'
Ty Construction U-value Or HIM Area (ft') Load Area (ft') Load
number (Btuh/ft2°F) (Btuh/ft2) or perimeter (ft) (Blob) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 3.41 2.29 0 0 0 0 2 24 8 55
. -G 4A5-2ob 0.520 n 19.50 12.53 0 0 0 0 0 0
. D 11N0 0.350 n 13.13 10.57 0 0 0 0 0 0
. W 12C-Osw 0.091 e 3.41 2.29 111 111 379 255 5 57 19 131
11 V,1 12C-Osw 0.091 s 3.41 229 135 120 409 275 0 0
-G 10D-b 0.520 s 19.50 9.75 0 0 0 0 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0 0 0 0 0
-G 4A5-2ob 0.520 s 19.50 13.85 15 6 293 208 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0 0 0 0 0
vv 12C-Osw 0.091 w 3.41 2.29 0 0 0 0 0 0
I 12B-Osw 0.097 3.64 1.69 0 0 0 0 0 0
I D 11NO 0.350 n 13.13 10.57 0 0 0 0 0 0
C 16B-38ad 0.026 - 0.98 1.40 185 185 180 258 5 55 54 77
F 22A-cp1 0.989 - 37.09 0.00 185 27 1014 0 55 9 334 0
I
6 c)AED excursion 46 -2
Envelope loss/gain 2275 1042 664 260
12 a) Infiltration 639 159 210 52
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 1 230 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2914 1431 874 313
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2914 1431 874 313
15 Duct loads 24% 47% 699 665 24% 47% 210 145
Total room load 3613 2096 1084 458
Air required(of m) 87 99 26 22
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft Right-Suite®Uni,,ersal2015 15.0.15 RSU20773 2015-May-21 10:47:29
g Page 6
'CC ...C\aWork File1R0515186-Begonia StR0515186.rup Cale=MJ8 Front Door faces:N
III wrightsoft Right-J® Worksheet Job: R0515186
Entire House Date: 20 MAY 2015
By: JT
Mr Kevin Martin
FL
1 Room name Hall Bedroom 2
2 Exposed wall 0 ft 31.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 6.3 x 6.3 ft 1.0 x 173.4 ft
5 Room area 40.1 ft' 173.4 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load
number (Btuh/ft'-°F) (Btutfft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 3.41 2.29 0 135 120 409 275
. �---G 4A5-2ob 0.520 n 19.50 12.53 0 15 0 293 188
I-2 D 11NO 0.350 n 13.13 10.57 0 0 0 0 0
. W 12C-Osw 0.091 e 3.41 2.29 0 111 111 379 255
11 W 12C-Osw 0.091 s 3.41 2.29 0 0 0 0 0
-G 10D-b 0.520 s 19.50 9.75 0 0 0 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0 0 0 0
-G 4A5-20b 0.520 s 19.50 13.85 0 0 0 0 0
L-G 4A5-2ob 0.520 s 19.50 12.53 0 0 0 0 0
W 12C-Osw 0.091 w 3.41 2.29 0 33 33 113 76
I 12B-Osw 0.097 - 3.64 1.69 0 0 0 0 0
D 11N O 0.350 n 13.13 10.57 0 0 0 0 0
C 16B-38ad 0.026 - 0.98 1.40 40 4 3 56 173 173 169 242
F 22A-cpl 0.989 - 37.09 0.00 40 0 173 31 1150 0
6 c)AED Excursion 0 -9
Envelope loss/gain 39 56 2512 1026
12 a) Infiltration 0 0 725 180
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 39 56 3237 1436
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 39 56 3237 1436
15 Duct loads 24% 47% 9 26 24% 47% 776 668
Total room load 48 82 4013 2104
Air required(cfm) 1 4 96 99
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
_D. -4--f4- wrightsc ft Right-Suite®Universal 2015 15.0.15 RSU20773 2015-May-211Pa7e7
...C4aWork File`R0515186-Begonia SfR0515186.rup Calc=MJ8 Front Door faces-.N g
+{+.wrightsoft Right-J® Worksheet Job: R0515186
Entire House Date: 20 MAY 2015
By: JT
Mr Kevin Martin
FL
1 Room name For Dining Rm
2 Exposed wall 6.7 ft 15.3 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 1.0 x 69.3 ft 11.7 x 12.3 ft
5 Room area 69.3 ft' 143.9 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load
number (Btuh/ft'-°F) (Btuhlfti or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 3.41 2.29 60 4 136 91 10 75 256 17
. -G 4A5.20b 0.520 n 19.50 12.53 0 0 3 0 58 37
. -D 11NO 0.350 n 13.13 10.57 20 2 264 21 0
. W 12C-Osw 0.091 e 3.41 2.29 0 0 3 33 11 7
11 W 12C-Osw 0.091 S 3.41 2.29 0 0 0
G 10D-b 0.520 s 19.50 9.75 0 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0 0
-0 4A5-2ob 0.520 s 19.50 13.85 0 0 0
G 4A5-2ob 0.520 s 19.50 12.53 0 0 0
W 12C-Osw 0.091 w 3.41 2.29 0 0 0
Fj 12 8-05w 0.097 - 3.64 1.69 0 0 111 111 404 18
I D 11NO 0.350 n 13.13 10.57 0 0 0 0 0
C 163-38ad 0.026 0.98 1.40 69 6 68 9 144 144 140 201
F 22A-cpt 0.989 - 37.09 0.00 69 247 144 15 569 0
1
6 c)AED excursion -3 -7
Envelope loss/gain 715 398 2066 1005
12 a) Infiltration 156 39 359 89
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 871 437 2425 1094
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 871 437 2425 1094
15 Duct loads 24% 47% 209 203 24% 47% 582 509
Total room load 1080 640 3006 1603
Air required(cfm) 26 30 72 76
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft 2015-May-2110:47:29
Right-Suite®Universal 2015 15.0.15 RSU20773 Page 8
.C1aWork File\R0515186-Begonia St1R0515186.rup Catc=MJ8 Front Door faces:N