Loading...
581 TIMBER BRIDGE LN - ENERGY SHEETS . --. FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CATALINA 3970 Left Builder Name: Toll Brothers Street: 581 Timber Bridge Lane(lot 161 AB) Permit Office: Atlantic Beach 11! : City,State,Zip: Atlantic Beach,FL, Permit Number. Owner: Toll Brothers Jurisdiction: 261300 f� Design Location: FL,St.Augustine 1. New construction or existing New(From Plans) ' 9. Wall Types(3856.8 sqft.) Insulation Area R=19.0 a.Frame-Wood,Exterior 3359.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 497.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (3522.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 3522.00 ft2 6. Conditioned floor area above grade(ft2) 3970 b.N/A R= ft2 . c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 R ft2 11.Ducts 7. Windows(520.6 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 416 a. U-Factor: Dbl,U=0.33 520.56 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 350 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 42.0 SEER:14.00 b.Central Unit 18.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: b.Electric Heat Pump 18.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.369 ft. • Area Weighted Average SHGC: 0.300 14.Hot water systems a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (3970.0 sqft.) Insulation Area EF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 b. Conservation features b.Floor over Garage R=0.0 590.00 ft2 None c.other(see details) R= 544.00 ft2 15.Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 94.88 PASS Total Baseline Loads: 97.83 .,;,. I hereby certify that the plans and specifications covered by Review of the plans and ,,�•'`p-GT' '9T.-�,. this calculation are in compliance with the Florida Energy specifications covered by this .' 4,# -.-, z r"�...:n.∎, Code. / calculation indicates compliance �yr„� ;' , with the Florida Energy Code. //.�� r�`c is : ;.n.'1. PREPAR i�� <, �i Before construction is completed �� 15--DATE: s 4� this building will be inspected for i 0 •,: ;Ax compliance with Section 553.908 * .,,F a . Florida Statutes. y;✓' �f hereby certify that this building,a .esigned,is in compliance •,,.±C••.................4o .- with the Florida Energy Code. i • r `<<,..QD ' �•'' • OWNER/AGEN BUILDING OFFICIAL: � . DATE: (1 i •� DATE: r'glo.I S` - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1 -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. . i 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 1 FORM R405-2014 PROJECT • Title: CATALINA 3970 Left Bedrooms: 5 Address Type: Street Address 3970 Lot# 101 Conditioned Area: 39 Building Type: User Owner: Toll Brothers Total Stories: 2 Block/SubDivision: AB #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: 581 Timber Bridge Lane Permit Office: Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) i Comment: , CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,St.Augustine FL_JACKSONVILLE_INT 2 32 93 70 75 . 1281 64 Medium BLOCKS Number Name Area Volume . 1 Blockl 2836 28360 2 Block2 1134 10206 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 2836 28360 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 1134 10206 No 2 2 1 Yes Yes Yes FLOORS ‘,./ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 390.5 ft 0 2836 ft2 0 0 1 V --- -— 2 Floor Over Other Space 2nd Floor 514 ft2 0 0 0 1 Vj 3 Floor over Garage 2nd Floor ___ ____ 590 ft2 0 0 0 1 V 4 Raised Floor 2nd Floor ___ ____ 30 ft2 0 0 0 1 ROOF • Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) \/ 1 Hip ' Composition shingles 3865 ft2 0 ft2 Medium 0.5 N 0.9 No 0 26.6 ' ATTIC V # Type Ventilation Vent__Ratio(1 in) Area RBS__ IRCC l 1 Full attic Vented 300 3456 ft2 N N 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 1 FORM R405-2014 CEILING y/ # Ceiling Type Space R-Value Area Framing Frac Truss Type • ✓/ 1 Under Attic(Vented) 1st Floor 38 2388 W 0.11 Wood V 2 Under Attic(Vented) 2nd Floor 38 1134 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt To Wall Typo Space R-vatuo Ft ip Ft In ArPa R-VaAno Frartinn• Aheor Grade°/ 1 SE Exterior Frame-Wood 1st Floor 19 • 8 9 10 0 87.5 ft2 0 0.23 0.7 0 / 2 E Exterior Frame-Wood 1st Floor 19 40 6 12 0 486.0 ft2 0 0.23 0.7 0 V 3 NW Exterior Frame-Wood 1st Floor 19 3 6 12 0 42.0 ft2 0 0.23 0.7 0 4 N Exterior Frame-Wood 1st Floor 19 49 0 12 0 588.0 ft2 0 0.23 0.7 0 5 NE Exterior Frame-Wood 1st Floor 19 3 6 12 0 42.0 ft2 0 0.23 0.7 0 6 W Exterior Frame-Wood 1st Floor 19 33 5 12 0 401.0 ft2 0 0.23 0.7 0 f 7 S Exterior Frame-Wood 1st Floor 19 20 1 10 0 200.8 ft2. 0 0.23 0.7 0 8 S Garage Frame-Wood 1st Floor 13 49 9 10 0 497.5 ft2 0 0.23 0.7 0 9 E Exterior Frame-Wood 2nd Floor 19 40 9 9 0 366.8 ft2 0 0.23 0.7 0 10 N Exterior Frame-Wood 2nd Floor 19 39 9 9 0 357.8 ft2 0 - 0.23 0.7 0 11 W Exterior Frame-Wood 2nd Floor 19 46 9 9 0 420.8 ft2 0 0.23 0.7 0 12 S Exterior Frame-Wood 2nd Floor 19 40 9 9 0 366.8 ft2 0 0.23 0.7 0 DOORS V # Ornt Door Type Space Storms U-Value Ft Width Height Area In Ft In • 1 SE Insulated 1st Floor None .6 3 8 24 ft2 V 2 S Wood 1st Floor None .6 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang i V # Ornt ID Frame Panes NFRC U Factor SHGC Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low E Double Yes 0.33 0.3 20.0 ft2 1 ft 4 In 1 ft 0 in None Interior 5 2 E 2 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 .1 ft 4 in 1 ft 0 in : None . Interior 5 V 3 NW 3 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft2 ft 4 in 1 ft 0 in None Interior 5 4 N 4 Vinyl Low-E Double Yes 0.33 0.3 96.0 ft2 9 ft 0 in 1 ft 0 in None Interior 5 ' • ..• •. 5•• N 4 Vinyl Low-E Double Yes 0.33 0.3 30:0 ft2 .1 ft 4.in 1 ft 0 in None Interior 5 6 N 4 Vinyl Low-E Double Yes 0.33 0.3 42.7 ft2 1 ft 4 in 1 ft 0 in None Interior 5 7 NE 5 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft2 6 ft 4 in 1 ft 0 in None Interior 5 8 W 6 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 1 ft 4 in 11 ft 0 in None Interior 5 1 9 W 6 Vinyl Low-E Double Yes 0.33 0.3 10.0 ft2 1 ft 4 in 11 ft 0 in None Interior 5 10 S 7 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 . 11 S 7 Vinyl •Low-E Double Yes 0.33 0.3 25.0 ft2 , 1 ft 4 in 1 ft 0 in None Interior 5 -12 W 11 Vinyl Low-E Double • Yes 0.33 0.3 45.0 ft2 1 ft.4 in 1 ft 0 in None- Interior 5 13 W 11 Vinyl Low-E Double Yes 0.33 0.3 3.6 ft2 1 ft 4 in 1 ft 0 in None Interior 5 - ►N14 S 12 Vinyl-Low-E Double Yes 0.33--0.3 20:0 ft26-ft 0i1 ft 0 In None Interior 5 15 S 12 Vinyl Low-E Double Yes 0.33 0.3 20.0 ft2 1 ft 4 In 1 ft 0 In None Interior 5 16 S 12 Vinyl Low-E Double Yes 0.33 0.3 33.3 ft2 6 ft 0 in 1 ft 0 in None Interior 5 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 - . 1 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. Wall \s// Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening •. 17 W 6 Vinyl Low-E Double Yes 0.33 0.3 8.0 ft2 1 ft 4 in 11 ft 0 in None Interior 5 V/ 18 N 4 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 ' V/ 19 S 12 Vinyl Low-E Double Yes 0.33 0.3 24.0 ft2 1 ft 4 in 1 ft 0 In None Interior 5 .v 20 E 2 Vinyl Low-E Double Yes 0.33 0.3 8.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 GARAGE • V # Floor•Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 683 ft2 94 ft' 64ft 10ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH . ACH 50 1 Wholehouse Proposed ACH(50) .000309 3213.8 176.44 331.81 .2926 5 . HEATING SYSTEM VI # System Type Subtype Efficiency Capacity Block Ducts • II 1// 1 Electric Heat Pump None HSPF:8.2 42 kBtu/hr 1 sys#1 V 2 Electric Heat Pump None HSPF:8.2 18 kBtu/hr 2 sys#2 - COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts y�� 1 Central Unit Split SEER: 14 42 kBtu/hr 1260 cfm 0.7 1 sys#1 V 2 Central Unit Split SEER:14 18 kBtu/hr 540 cfm 0.7 2 sys#2 HOT WATER SYSTEM J # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Garage 0.59 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM • . I ✓ FSEC Collector Storage /• Cert # Company Name System Model# • Collector Model# Area Volume. FEF k None None ft2 DUCTS V —Supply— —Return-- Air CFM 25 CFM25 HVAC# # Location. R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool • 1 Attic 6 416 ft2 - Attic 210 ft2 Default Leakage Attic (Default) (Default) 1 1 - 2 Attic 6 350 ft2 Attic 242 ft2 Default Leakage Attic (Default) (Default) 2 2 • i 8/6/2015 10:11 AM EnergyGaugee USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 -- r FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Ma Jun X Jul X Au X Sep Oct Nov Dec Heating Jan Feb Mar May Jun Jul Au Se Oct Nov Dec Venting Jan Feb [xl Mar lArr Apr May Jun Jul Aug Sep �X�Oct [xi Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 80 78 78 78 78 78 78 78 80 80 80 Cooling(WEH) - PM 78 78 78 78 78 • 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM • 68 68 68 68 68 68 68 68 68 68 66 66 , • • • • ' I 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY .PERFORMANCE LEVEL (EPL) DISPLAY CARD 4 1 ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index,the more efficient the home. • 1 , 581 Timber Bridge Lane (lot 161 AB), Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 3359.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 497.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 " 4. Number of Bedrooms 5 d.N/A • R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 3522.00 ft2 6. Conditioned floor area(ft2) 3970 b.N/A R= ft2 c.N/A R= ft2 7. Windows" Description Area R ft2 11.Ducts a. U-Factor: Dbl,U=0.33 520.56 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 416 SHGC: SHGC=0.30 b.Sup: Attic,Ret:Attic,AH:Attic 6 350 b. U-Factor. N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: b.Central Unit 18.0 SEER:14.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.369 ft. b.Electric Heat Pump 18.0 HSPF:8.20 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems Cap:1 gallons I a.Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 a.Natural Gas EF:0.59 i b.Floor over Garage R=0.0 590.00 ft2 b. Conservation features c.other(see details) R= 544.00 ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building .,..4" IgBST4 ;••:., Construction through the above energy saving features which will be installed (or exceeded) -' 0 ....:. ,._, F in this home before final inspectio . Otherwise, a new EPL Display Card will be completed /40"..,-y ,,, _/ ., based on installed Code co yell. eatures. ''`' .';'�, a_ Builder Signature: /JA Date: 1� `�'.. a. Address of New Home: 11 L ,Y' 1 City/FL 1p: 322-3 3 �a::fl%c .........` 4•`�•• ..,....... . *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy/Gauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods I ADDRESS: 581 Timber Bridge Lane(lot 161 AB) Permit Number: Atlantic Beach,FL, MANDATORY REQUIREMENTS See individual code sections for full details. p 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains Information Indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. • ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. p R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed In Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. o R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight-fitting flue dampers and outdoor combustion air. o R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm - per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. o .R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage • between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not . . more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. • ❑ R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction • or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free`by either of the following: • 1. Post-construction test:Total leakage shall be less than or equal to 4.cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,Including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and alr handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. • ❑. R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. • ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., 0 R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused • by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑. . R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. •• ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have . I heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls • capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for•the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, • and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in Installed solar water heating systems should meet the following criteria: - 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the ❑ Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. •. - Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. O R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. O R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed . garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating*equipment. 0—R403.6.1 Equipment sizing—Heating and cooling equipment shall be sized-in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,• • • • • •-• based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: • 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • ▪ R403.6.1.2.3•Fossll fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not 9 of be less than the design load calculated in accordance with Section R403.6.1. •O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. - - - - R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum • thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. •Where public health standards require 24-hour pump operations. . 2. Where pumpsare required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently Installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 • FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA !i Project Name: CATALINA 3970 Left Builder Name: Toll Brothers Street: 581 Timber Bridge Lane(lot 161 AB) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner. Toll Brothers Jurisdiction: 261300 Design Location: FL,St.Augustine COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the \ insulation and any gaps in the air barrier shall be sealed. v Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. --'----J Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and `- framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. N. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. 0 Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating ihem from the.showers and tubs. N. - Electrical/phone box on The air barrier shall be installed bbhind'electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/612015 10:11 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 r I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: CATALINA 3970 Left Builder Name: Toll Brothers Street: 581 Timber Bridge Lane(lot 161 AB) Permit Office: Atlantic Beach . City,State,Zip: Atlantic Beach,FL, Permit Number: - • Design Location: FL,St.Augustine Jurisdiction: 261300 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE I FLOW: . I ELA: EqLA: ACH: ACH(50): 1 i SLA: I R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures;•- --• -- 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,If installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, /D11KE.Zli:;! performance results demonstrate compliance testing shall be conducted by an '�'•% 74, _ D•,6 with Florida Energy Code requirements in approved third party.A written 3" '''/r f� ' ' ` s' f�;,run . ,, .• ,! accordance with Section R402.4.1.2. report of the results of the test shall • • - be signed by the third party ; ..•. ' • I conducting the test and provided to .V� 6 • the code official. . -....... SIGNATURE: ' ,�,�;' _1(,..t.,_:,, PRINTED NAME: `t«•...„......00° BUILDING OFFICIAL: DATE DATE: 0 8/6/2015 10:11 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Softwar Page 1 of 1 McGowan ` Project Summary Da e: 581 Timber Bridge Ln L... Heating&Air (Rest of House) By: Stephen Barber Condition*,M 00,". V McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Pro'ect Information For: Toll Brothers Fl Notes: Catalina Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 94 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 19 °F Daily range M Relative humidity 50 Moisture difference 47 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 31608 Btuh Structure 19208 Btuh Ducts 4207 Btuh Ducts 4892 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 35815 Btuh Use manufacturer's data n Rate/swing multiplier 0.99 Infiltration Equipment sensible load 30206 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2826 Btuh Ducts 742 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2836 2836 Equipment latent load 5662 Btuh Volume(ft3) 31451 31451 Air changes/hour 0.25 0.13 Equipment total load 35868 Btuh Equiv.AVF(cfm) 131 70 Req.total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB042 Cond CH14NB042 AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28700 Btuh Heating output 40000 Btuh @ 47°F Latent cooling 12300 Btuh Temperature rise 27 °F Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.057 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri —----' 2015-Aug-06 09:50:08 g Comfort Builder by Wr ghtsofl 15.0.17 RSU12270 Page 1 ACak ..300 RES NC\Toll Brothers\CATALINA 3970 Left.rup Calc=MJ8 Front Door faces:SE //'G�o�w,.,, Project Summary Job: 581 Timber Bridge Ln L... VV11r�n Date: 8/6/2015 Heating&Air l UP STAIRS By: Stephen Barber Con tinning .. McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Pro'ect Information For: Toll Brothers Fl Notes: Catalina Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 94 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 19 °F Daily range M Relative humidity 50 % Moisture difference 47 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 12171 Btuh Structure 9053 Btuh Ducts 1549 Btuh Ducts 1888 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13720 Btuh Use manufacturer's data n Rate/swing multiplier 0.99 Infiltration Equipment sensible load 14042 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1657 Btuh Ducts 285 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 1134 1134 Equipment latent load 1942 Btuh Volume(ft3) 12604 12604 Air changes/hour 0.35 0.19 Equipment total load 15984 Btuh Equiv.AVF (cfm) 74 40 Req.total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB018 Cond CH14NB018 AHRI ref Coil FB4CNP018 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17200 Btuh @ 47°F Latent cooling 5340 Btuh Temperature rise 26 °F Total cooling 17800 Btuh Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. l" wrightsdft° Comfort Builder by\ ightsoft 15.0.17 RSU12270 2015-Aug-06 09:5ge �"� Page 2 ..300 RES NC\Toll Brothers\CATALINA 3970 Left.rup Calc=MJ8 Front Door faces:SE • N 1 First Floor -1--\\ 1 : .. 2x6 I • 6x12 ■ 7" NOOK/KITCHEN GR T ROOM 6x12 ahlhu MASTER BED 7" 14" 14x6 14x6 j r..12x6 r.• 8" 8" ••• 7" Ret 10x6 16 x 16 'Al Riser • , .. 7" 14" FA 19 '24 AL U Sup 1.5 3"Fan 0p 9 " Sup Riser D ING a Riser 3 " HIS WC 1 8x4 8 x 4 10x10 01,41 4„ 4„ 4x8 9., I 10X 10 HALL 4 . r ■ CLOSET 8" a 12x12 ". 12x6 MASTER BATH ; 6 x 12 ' 4x8 : 6x101 4" 5" ' 10x STUDY HERS ' 6 \j 3"Fan 1 3 i FOYER (\7.---- -- 10" 4x8 3"Fan aii 4" PO APE 14x14 GARAGE Si r 4x8 4 WI. 2: 14x14 12" ■ 6x14 3"Fan w 8 BED 2 H 4x8 4" Job #: 581 Timber Bridge Ln Lot 161 McGowan's Heating & Air Conditioning Scale: 1 : 106 Performed by Stephen Barber for: Page 1 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.17 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2015-Aug-06 09:51:45 www.mcgowansac.com jjacobs @mcgowansac.com Brothers\CATALINA 3970 Left.rup • h G —;1r. 2ND FL Ret Riser 18" ' STORAGE/UNFINISHED Sup 14" Riser 12" r ";1' Sup ■ • 12"@Y,^^^•�......,.,"�+' "'^^ Riser '6.. 14" WIC3 6 1 2-way BED3 Sx4 i 12x6 12x12 lJ q• 8 x 4 4" BATH SINKS 18 x 18 3"Fan �J 12 12 x 12 6 x 12 10" 0•• STAIRS/FOYER UP 14x6 T _ F3ED 4 6x'2 Job #: 581 Timber Bridge Ln Lot 161 McGowan's Heating & Air Conditioning Scale: 1 : 106 Performed by Stephen Barber for: Page 2 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.17 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2015-Aug-06 09:51:46 www.mcgowansac.com jjacobs @mcgowansac.com ...Brothers\CATALINA 3970 Left.rup //����,.,,������ Duct System Summary Job: 581 Timber Bridge Ln L... VVl�rSn l Date: 8/6/2015 Heating&Air ,�' (Rest of House) By: Stephen Barber FelditiMing McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:pacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.350/0.150 in H2O 0.350/0.150 in H2O Lowest friction rate 0.125 in/100ft 0.125 in/100ft Actual air flow 1367 cfm 1367 cfm Total effective length(TEL) 399 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH 2 h 1270 48 25 0.144 4.0 Ox 0 VIFx 63.1 180.0 st9 BED 2 h 4833 184 123 0.145 8.0 Ox 0 VIFx 61.1 180.0 st9 DINING c 2090 83 119 0.179 7.0 Ox 0 VIFx 35.5 160.0 st5 FOYER h 2473 94 62 0.162 6.0 Ox 0 VIFx 51.0 165.0 st5 GREAT ROOM c 2460 138 140 0.173 8.0 Ox 0 VIFx 37.4 165.0 st5 GREAT ROOM-A c 2460 138 140 0.173 8.0 Ox 0 VIFx 37.9 165.0 st5 HALL-A c 934 40 53 0.169 5.0 Ox 0 VIFx 36.6 170.0 st7 HERS h 415 16 11 0.165 4.0 Ox 0 VIFx 37.6 175.0 st7 HIS h 540 21 8 0.134 4.0 Ox 0 VIFx 56.6 205.0 st8 LAUNDRY c 6 0 0 0.179 4.0 Ox 0 VIFx 31.0 165.0 st7 MASTER BATH c 1859 94 105 0.140 7.0 Ox 0 VIFx 44.5 205.0 st8 MASTER BED c 2111 111 120 0.127 7.0 Ox 0 VIFx 75.2 200.0 st6 MASTER BED-A c 2111 111 120 0.129 7.0 Ox 0 VIFx 71.2 200.0 st6 NOOK/KITCHEN c 1877 68 106 0.125 7.0 Ox 0 VIFx 79.3 200.0 st6 NOOK/KITCHEN-A C 1877 68 106 0.128 7.0 Ox 0 VIFx 74.1 200.0 st6 POWDER h 253 10 7 0.140 4.0 Ox 0 VIFx 64.8 185.0 st9 STUDY h 3480 133 114 0.165 7.0 Ox 0 VIFx 46.6 165.0 st5 WC c 4 0 0 0.141 4.0 Ox 0 VIFx 48.5 200.0 st8 wlc 2 h 252 10 8 0.146 4.0 Ox 0 VIFx 59.4 180.0 st9 2015-Aug-06 09:50:08 ,,^ti -f wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 . ...300 RES NC%Toll Brothers\CATALINA 3970 Left.rup Calc=MJ8 Front Door faces:SE Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st8 Peak AVF 115 113 0.134 329 8.0 0 x 0 VinIFIx st7 st7 Peak AVF 171 177 0.134 401 9.0 0 x 0 VinIFIx st3 st2 Peak AVF 944 1026 0.125 735 16.0 0 x 0 VinlFlx st6 Peak AVF 357 452 0.125 423 14.0 0 x 0 VinIFIx st5 st5 Peak AVF 944 1026 0.125 735 16.0 0 x 0 VinIFIx st2 st3 Peak AVF 423 341 0.134 538 12.0 0 x 0 VinIFIx st9 Peak AVF 252 163 0.140 462 10.0 0 x 0 VinIFIx st3 Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 378 461 119.6 0.125 431 14.0 Ox 0 VIFx rt2 rb11 Ox 0 479 340 92.7 0.162 1085 9.0 Ox 0 VIFx rt2 rb10 Ox 0 509 567 114.0 0.131 530 14.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt2 Peak AVF 1367 1367 0.125 774 18.0 0 x 0 VinIFIx 2015-Aug-06 09:50:08 wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 /C411 ...300 RES NC\Toll Brothers\CATALINA 3970 Left.rup Cale=MJ8 Front Door faces:SE McGt wan Duct System Summary Job: 581 Timber Bridge Ln L... Heating Date: 8/6/2015 UP STAIRS By: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:www.mcgowansac.com i Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.300/0.200 in H2O 0.300/0.200 in H2O Lowest friction rate 0.148 in/100ft 0.148 in/100ft Actual air flow 593 cfm 593 cfm Total effective length(TEL) 339 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH c 371 17 20 0.187 4.0 Ox 0 VIFx 30.6 130.0 st1 BED 3 c 2662 89 144 0.191 7.0 Ox 0 VIFx 27.3 130.0 st1 BED 4 c 2447 118 133 0.148 8.0 Ox 0 VIFx 38.4 165.0 st4 LOFT h 2762 119 95 0.155 7.0 Ox 0 VIFx 33.6 160.0 st4 ' LOFT-A h 2762 119 95 0.153 7.0 Ox 0 VIFx 36.6 160.0 st4 LOFT-B h 2762 119 95 0.199 7.0 Ox 0 VIFx 20.9 130.0 st1 SINKS c 71 2 4 0.200 4.0 Ox 0 VIFx 25.1 125.0 st1 WIC 3 h 185 8 6 0.199 4.0 Ox 0 VIFx 21.0 130.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 357 324 0.148 455 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 593 593 0.148 555 14.0 0 x 0 VinIFIx 2015-Aug-06 09:50:08 y''.'.,: wrightsoft. Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 3 +k. ...300 RES NC\Toll Brothers\CATALINA 3970 Left.rup Calc=MJ8 Front Door faces:SE . - Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox 0 239 191 99.0 0.202 438 10.0 Ox 0 VIFx ill rb3 Ox 0 114 170 90.0 0.222 385 9.0 Ox 0 VIFx di rb6 Ox 0 240 232 135.5 0.148 543 9.0 Ox 0 VIFx ill Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 593 593 0.148 555 14.0 0 x 0 VinIFIx 2015-Aug-06 09:50:08 wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 4 AL ...300 RES NC1Toll Brothers1CATALINA 3970 Left.rup Calc=MJ8 Front Door faces:SE I McGowan Manual S Compliance Report Job: 581 Timber Bridge Ln L... Heating&Air 481 Date: 88/6/2015 �, (Rest of House) By: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 34382 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 2791 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 37173 Btuh Indoor RH: 50% Estimated airflow: 1333 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L Actual airflow: 1333 cfm Sensible capacity: 34382 Btuh 100%of load Latent capacity: 2791 Btuh 100%of load Total capacity: 37173 Btuh 100%of load SHR: 92% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 33050 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L Actual airflow: 1333 cfm Output capacity: 40000 Btuh 121%of load Capacity balance: 27 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1333 cfm Output capacity: 9.7 kW 100%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Aug-06 09:55:27 wrightsot+ Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 ...NC\Toll Brothers13.5 TON-1.5 TON Manual S.rup Calc=MJ8 Front Door faces:SE Mc Gm" Manual S Compliance Report Job: 581 Timber Bridge Ln L... • Heating Air Date: 88/6/2015 Conditioning ? UP By: Stephen Barber 0•P•dietft McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 14930 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.2°F Latent gain: 1722 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 16652 Btuh Indoor RH: 50% Estimated airflow: 593 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A+FB4CNP018L Actual airflow: 593 cfm Sensible capacity: 14930 Btuh 100%of load Latent capacity: 1722 Btuh 100%of load Total capacity: 16652 Btuh 100%of load SHR: 90% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 11541 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A+FB4CNP018L Actual airflow: 593 cfm Output capacity: 17800 Btuh 154%of load Capacity balance: 23 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 593 cfm Output capacity: 3.3 kW 97%of load Temp. rise: 17 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Aug-06 09:55:27 ,�/C wrightsoft° Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 AM ...NC\Toll Brothers\3.5 TON-1.5 TON Manual S.rup Calc=MJ8 Front Door faces:SE