Loading...
1698 MARITIME OAK DR - ELEV. CERT, DENSITY REPORT cane. . FORM BOARD ELEVATION CE IFICATE DATE: -/_3-4,5- PERMIT NUMBER: /- s/ - /y‘. ADDRESS: / n /a,,' oa 4 fir. A.A.S. WORK ORDER NO. / '1 ?2 REQUIRED SLAB ELEVATION ON CITY APPROVED SITE PLAN: ACTUAL ELEVATION OF FORM BOARD OR GRADE STAKE: '`si /Li. Jo SURVEY COMPANY NAME: ALL AMERICAN SURVEYORS OF FLORIDA INC. 6820 SOUTHPOINT PARKWAY, SUITE 4 JAX, FL 32216 (904) 279-0088 SIGNATURE OF SURVEYOR: (Party Chief) I gpUNIVERSAL UES Project No: 0910.1400187.0000 Workorder No: 159140-1 ENGINEERING SCIENCES Report Date: 8/17/2015 Consultants In:Geotechnical Engineering•Environmental Sciences Geophysical Services•Construction Materials Testing•Threshold Inspection Building Inspection•Plan Review•Building Code Administration 5561 Florida Mining Blvd So., Jacksonville, 32257 • P:904-296-0757 • F: 904-296-0748 Ca ill Appi In-Place Density Test Report nl Client: UES Technician: Jody Swathwood 160 Cape May Avenue Ponte Vedra, FL 32081 Date Tested: 08/17/2015 Project: Atlantic Beach Country Club Area Tested: tlantic Beach Country Club Lot 119 Housepad Type of Test: Material: Fill Field: ASTM D-6938 Nuclear Gauge Metho Reference Datum: 0 = Top of Fill Laboratory: ASTM D1557 Modified Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Maximum optimum Field Dry Field Soil Fill Test Densi Densit Depth Pass tY Moisture Y Moisture Compaction (inch) or Fail No. Location of Test Range (pcf) (%1 (pcf) (%1 1%1 1 South end of housepad 119 0-1 ft 105.3 14.0 101.6 9.5 96 N/A Pas_ 2 East end of housepad 119 0-1 ft 105.3 14.0 100.8 9.8 96 N/A Pas: 3 West end of housepad 119 0-1 ft 105.3 14.0 102.2 9.5 97 N/A Pas: 4 Center of housepad 119 0-1 ft 105.3 14.0 102.3 9.7 97 N/A Pas: 5 North Corner of housepad 119 _- 105.3 14.0 101.1 9.9 96 N/A Pas: To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization UNIVERSAL UES Project No: 0910.1400187.0000 II p Workorder No: 159410-1 ENGINEERING SCIENCES Report Date: 8/26/2015 Consultants In:Geotechnical Engineering•Environmental Sciences Geophysical Services•Construction Materials Testing•Threshold Inspection Building Inspection•Plan Review•Building Code Administration 5561 Florida Mining Blvd So.,Jacksonville, 32257 • P:904-296-0757 • F: 904-296-0748 1,3 In-Place Density Test Report &1-9 Client: UES Technician: Jody Swathwood 160 Cape May Avenue Date Tested: 08/26/2015 Ponte Vedra, FL 32081 Project: Atlantic Beach Country Club Area Tested: Atlantic Beach Country Club Lot #119 Type of Test: Material: Fill Field: ASTM D-6938 Nuclear Gauge Metho Reference Datum: 0 = Top of Fill Laboratory: ASTM D1557 Modified Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Maximum Optimum Field Dry Fill D timum ry Field Soil Depth Pass Test Density Moisture Density Moisture Compaction No. Location of Test Range (pcf) (%) (pcf) 1%) (%) (inch) or Fail 1 East end of pad 0-1 ft 105.3 14.0 100.1 18.5 95 N/A Pas: 2 West end of pad 0-1 ft 105.3 14.0 100.4 17.2 95 N/A Pas: 3 Center of pad 0-1 ft 105.3 14.0 101.1 16.1 96 N/A Pas: To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and authorization