374 11TH ST - HVAC f 1�s f; CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-2131 Job Type: MECHANICAL HVAC ONLY Description: 1 CU 1 AHU 4 TONS Estimated Value: Issue Date: 9/10/2015 Expiration Date: 3/8/2016 PROPERTY ADDRESS: Address: 374 11TH ST RE Number: 170087-0000 PROPERTY OWNER: Name: OSTERGREN• KAREN A Address: 374 11TH ST GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN Phone: 904-241-3785 PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $32.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 TotalPayments: $115.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 t 54-m ECu -Z 13 FOB ADDRESS: 3T`1 I ifik 54 A 6 t-/ -?aa33 PERMIT# PROJECT VALUE $ ARI# 793C1-11 REQUIRED _Air Handling Equipment Only _,,Air Handling Unit & Condenser Condenser Only gEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity ! Tons Per Unit `'I Heat: Unit Quantity I BTU's Per Unit 92- Seer Rating f-I Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) +IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have rcad tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name 14®..CC\ (35-}-tttycr, Phone Number Qt-19 - 1'SvJ Mechanical Company iD\On \atio.N a- A i r Office Phonea91 3) Fax :o. Address: I C, G41, Ave c\i- '\ . City j,y, J <c t.t., State j--L Zip '3 3.., S .icense Holder(Print): �,J \ \A ,0 3•-■ .. o-``C ,voc- State Certification/Registration# Notarized Signature of License Holder U101y�/l t.-- 7____,------_ giVirk, RICHARD TOMPKINS Before me this q day of . - 20 -., ,ai' •% Commission#FF 040399 =;;-,..47:, Expires July 29,2017 Signature of Notary Public . .rte Bonded Than Troy Fein Insurance 800388.7010 Project Summary Jobt •a Date: September 7,2015 Entire House By: Donovan Heat & Air 315 6th Ave 5,JacksonvIlle Beech,FL 32250 Phone:904-241-3795 Fax:904.241.3745 Email:eerohndonovanse.com Web:www.danovenac.com Pro'ect Information •• • • . • For: Karen Ostergren 374 11th St, Atlantic Beach, FL 32233 Notes: Desi••n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outsid. db 39 °F Outside db 99 °F Inside db 70 "F Inside db 75 °F Design TD 31 "F Design TD 24 °F Daily range L Relative humidity 55 Moisture difference 62 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 24583 Btuh Structure 23407 Btuh Ducts 6052 Btuh Ducts 9079 Btuh Central vent(62 cfm) 2101 Btuh Central vent(62 cfm) 1627 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32736 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 35477 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 3361 Btuh Ducts 2413 Btuh Heating Cooling Central vent (62 cfm) 2617 Btuh Area (ft') 2263 2263 Equipment latent load 8390 Btuh Volume (ft3) 22630 22630 Air changes/hour 0.37 0.16 Equipment total load 43868 Btuh Equiv, AVF (cfm) 141 60 Req, total capacity at 0.70 SHR 4.2 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 14 SEER N Series R410A HP Trade 14 SEER N Series R410A HP Model N4H448 Cond N4H448 ARI ref no. 7939713 Coil FEM4X48*".. ARI ref no. 7939713 Efficiency 8,2 HSPF Efficiency 14 EER Heating input Sensible cooling 33600 Btuh Heating output 46000 Btuh ©47°F Latent cooling 14400 Btuh Temperature rise 26 °F Total cooling 48000 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 3.80 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. f�x -.r- wrigrlht�cyft'• Right-5008 Unlvertel 7.1.01 RSU05995 2015•Sep•06 09:31:25 rt.-4•t'. C:tDocumnnts end Settings\OpMan\My DocumerotVrightsoR MIVAC,Tempiate■Bogus 1 Ten rue c?Ic=MJ8 Page 1