Loading...
1957 W SEVILLA BLVD - HVAC 0 , , ff l Sig CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD -" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �JF31�? MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-2246 Job Type: MECHANICAL HVAC ONLY Description: 1 cu 1 ahu 3 tons Estimated Value: Issue Date: 9/23/2015 Expiration Date: 3/21/2016 PROPERTY ADDRESS: Address: 1957 W SEVILLA BLVD RE Number: 169462-0355 PROPERTY OWNER: Name: MANKIN, HAROLD TURNER II Address: 1957 W SEVILLA BLVD GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN Phone: 904-241-3785 PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $24.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $107.00 PI'RNIIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904)247-5826 Fax (904) 247-5845 loBADDRESS: 14 1 Scv.%lla 1.106 . P M _ — PERMIT# o,„ PROJECT VALUE $_ 36750-1 ARI# 75� (q REQUIRED _Air Handling Equipment Only )k Air Handling Unit & Condenser Condenser Only ■TEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating. Duct Systems: Total CFM REQUIRED IEPLACEVIENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity_ I Tons Per Unit 1 G Heat: Unit Quantity I BTU's Per Unit 3(J Seer Rating IC Duct Systems: Total CFM ?ME PREVENTION uanti (Requires 3 sets of plans) Fire Sprinkler System Q �' Fire Standpipe Quantity (Requires plans) uires 3 sets of Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity _ (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) TIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets �_ Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: --- ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will he complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name a r1\L J 1 Phone Number 610 -TVA Mechanical Company c�'e 1Vs.4.. \-\_(.> A.c Office Pbonea4 t-37 Fax ;o. Address: 3 1 S 4Ft~.. City l�c __ State!'L ,Zip 3341.3 .1icense Holder(Print): 4..1,1\s_ t ‘`'dyon State Certification/Registration#GPI0 3i1 i;( Jotarized Signature of License Holder 1 f '""..«..."...y""'." day of Sc,P 20_(5 ''nY�i'� RICHARD 7`'1�1"' ,`t'� Before me this aa s. .• ..= Commissiol, 'FF.i1d()399 ' `` ' .r., Expires July 29,2017 Signature of Notary Public "1: pMdad tfim Tao;Fe%knrenMA004a64016 O"^ Project Summary JOb:Date: September 20,2015 Entire House ay: Donovan Heat & Air 315 6th Ave S.Jacksonville Beach.FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron(gdOnovantlC.COf Web:vrvrw.donovanec.com Pra'ect Information. * For: Hal Mankin 1957 Sevilla Blvd, Atlantic Beach, FL 32233 Notes: i� •Desi•n information . • Weather: Jacksonville Mayport Naval, FL, US 1 Winter Design Conditions Summer Design Conditions I Outside db 39 'F Outside db 99 °F Inside db 70 °F Inside db • Design TD 31 OF Design TD 24 °F Daily range 66 L Relative humidity Moisture difference 62 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18185 Btuh Structure 17651 Btuh Ducts 3586 Btuh Ducts 5334 Btuh Central vent(26 cfm) 883 Btuh Central vent(26 cfm) 683 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22653 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 24615 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2713 Btuh Ducts Heating Cooling Central vent (26 cfm) 1099 Btuh Area(ft2) 1176 1176 Equipment latent load 5200 Btuh Volume(ft') 11760 11760 Air changes/hour 0.55 0.23 Equipment total load 29815 Btuh Equiv. AVF (cfm) 108 45 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade XL16 Trade XL16 Model 4TW6036H1 Cond 4TW6036H1 ARI ref no. 7564819 Coil TEM6A0C36 ARI ref no. 7564819 16 SEER Efficiency 9 HSPF Efficiency Heating input Sensible cooling 25340 Btuh Heating output 32800 Btuh @ 47'F Latent cooling 10860 Btuh Temperature rise 25 'F Total cooling 36200 Btuh Actual air flow 1207 cfm Actual air flow 1207 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.82 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. . 41- wrtgI-at' fit- Right-Sae)Universal 7.1 01 R5U05995 2015-Sep-21 17:29:05 AC C:1Documents and$ettingstOpMan\My DocumentstWrlphtaort HVAC17emplate\Bogus 3.5 Ton.ruo Calc=MJ Pa9C 1