781 CAMELIA ST - HVAC -SL�jr S, CITY OF ATLANTIC BEACH f 800 SEMINOLE ROAD j r ATLANTIC REACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-2285 Job Type: MECHANICAL HVAC ONLY Description: 1 CU 1 AHU 2.5 TONS Estimated Value: Issue Date: 9/29/2015 Expiration Date: 3/27/2016 PROPERTY ADDRESS: Address: 781 CAMELIA ST RE Number: 170937-0010 PROPERTY OWNER: Name: SCHRADER, MATTHEW H Address: 781 CAMELIA ST GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN Phone: 904-241-3785 PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $20.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $103.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 fOB ADDRESS: 7K; (.o Mi, I Q. 5+ 42 f x L 20a 33 PERMIT# PROJECT VALUE $ LICOO ARI# 7 g99 o--7g REQUIRED _Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only — JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity ___ BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit , S Heat: Unit Quantity I BTU's Per Unit Seer Rating ) 5 Duct Systems: Total CFM REQUIRED ■IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) ■IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read Us application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name S 6 1-N e,.cO-acs Phone Number 3y 9 - 5 73 Mechanical Company 'OK■c e \-\ Office Phone: -1V5 Fax ;o. Address:3t . L 4 L 5o CitySed, State3L Zip 04133 .icense Holder(Print): k,.i��\`��*^ �o�ws�� State Certification/Registration#C 976 ■otarized Signature of License Holder � - -- OA, RICHARD TOMPKINS efore me this 9J day of �Le 20 1 S a•: • #) Commission#FF 040399 P-n4 Babied btu �s °"SOO.365-70111 ignature of Notary Public Ail- wr" htsoft° Project Summary Job: By; Bran 015 Entire House y: Brandon 2aharfo Donovan Heat & Air 315 6th mit south,Jacksonville Bench,FL 32250 Phan:241-3785 Email:brendorj donovnnc,Com imeme■' ....e' Amy / .. Pro'ect Information For: SCHARADER 781 Camelia st,Atlantic Beach, FL 32233 Notes: Desi n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 68 °F Inside db 75 °F Design TD 29 °F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 14414 Btuh Structure 14371 Btuh Ducts 3195 Btuh Ducts 4674 Btuh Central vent (13 cfm) 409 Btuh Central vent (13 cfm) 282 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18019 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19327 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1921 Btuh Ducts 1006 Btuh Heating Cooling Central vent (13 cfm) 465 Btuh Area (ft") 1218 1218 Equipment latent load 3392 Btuh Volume(ft3) 10962 10962 Air changes/hour 0,56 0.23 Equipment total load 22718 Btuh Equiv.AVF (cfm) 102 42 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade Trade Model 4TWR5030 Gond 4TWR5030 AR I ref no, 7599075 Coil TEM6A0B30 ARI ref no. 7599075 Efficiency 9 HSPF Efficiency 15 EER Heating input Sensible cooling 20906 Btuh Heating output 29717 Btuh @ 47°F Latent cooling 8960 Btuh Temperature rise 34 °F Total cooling 29866 Btuh Actual air flow 801 cfm Actual air flow 801 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. - 4•44- wricshtso7°e- Right-Suttee Universal 7.1.01 RS1,105996 2015-Sep•21 09:40:43 C:11.4eralSales lDocumentaSWrlghteoit HVAC12.5 TON Ce4c-MJ8 OrlentetIon=N Page 1 D oNovAN • • 904/241-3785 Since 1987 H'4���4'84.��.tl: �„° Fa. ^ax 241-3745 CAC() 3976'! ACO 58398 S15 6th Ave.South,Jacksonville Beach,FL 32250 to IV. RN!T." .Went Your Business...Give Us the Opportunity r To• ACk From L r 2va n gea 41� FRE •dt/ C7 - 5& Pages: 3 �.�0,2( • • _ goof . (/7 - Data: Re: . cc Gl uryent ®For Review FJ Please Cerulean! []Please Reply 0 Please Recycle e C ramen : • Por er.04rr www.donovanac.co l