Loading...
1805 ATLANTIC BEACH DR - ENERGY SHEETS FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cumberland 2803 Left SW Builder Name: Toll Brothers Street: 1805 Atlantic Beach Dr.(Lot 42 AB) Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number. Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(3325.9 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 3127.90 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 198.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (2803.0 sqft.) Insulation Area 5. Is this a worst case? • No a.Under Attic(Vented) R=38.0 2803.00 ft2 6. Conditioned floor area above grade(ft2) 2803 b.N/A R= ft2 c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(284.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 980 a. U-Factor. Dbl,U=0.34 284.00 ft2 SHGC: SHGC=0.27 12.Cooling systems kBtu/hr Efficiency b. U-Factor. N/A ft2 a.Central Unit 36.0 SEER:14.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 36.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 3.223 ft. 14.Hot water systems Area Weighted Average SHGC: 0.270 a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (2803.0 sqft.) Insulation Area EF:0.600 a.Slab-On-Grade Edge Insulation R=0.0 2189.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 614.00 ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 66.13 PASS Glass/Floor Area:. 0.101 Total Baseline Loads: 72.69 '���4li.u.,.Y.ry�r�A� I hereby certify that the plans and specifications covered by Review of the plans and �.'0 . E ST,.4 :,.; this calculation are in compliance with the Florida Energy specifications covered by this ,�, �? 5 .��,''�• Code. calculation indicates compliance c../.4?.. CO %��,t''..;'�" sN.'ytN,o n i� / with the Florida Energy Code. 'tano . %• :F-r. ^ ,�'O ' PREPARED BY !�f tIZ et � - Before construction is completed . �. - this building will be inspected for `� q .� a DATE: D��O L� i a I compliance with Section 553.908 * * ; Florida Statutes. . \ ....,. `1- c ��' I hereby certify that this building,as designed,is in compliance `' COD yrL T ,,t�° with the Florida Energy •de , `Q01). ,wE' ,.N� OWNER/AGENT: �� & A BUILDING OFFICIAL: DATE: q 03 I DATE: I w` • -j - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as • certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. OFFICE COPY • 9/2/2015 3:37 PM EnergyGaugee USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 ___ _.__ _. ._. ____.______.____ __...._._.__._ ._._-..-_. ___._ _.._. ..__._..__._.. .._..._._ .-_-.__..___._._. ..__..._.__._.__._ _ __._____. _...__.___.___.._.T # . FORM R405-2014 PROJECT • Title: Cumberland 2803 Left SW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2803 Lot# Owner. Toll Brothers Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: 1805 Atlantic Beach Dr. Permit Office: Duval Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE V IECC Design Temp Int Design Temp Heating Design Daily Temp f Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 2803 27416 SPACES Number Name Area Volume Kitchen Occupants Bedrooms !Mil ID Finished Cooled Heated 1 Main 2189 21890 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 614 5526 No 1 . 1 1 Yes Yes Yes FLOORS V/ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _ V/ 1 Slab-On-Grade Edge Insulatio Main 211.8 ft 0 2189 ft2 0 0 1 V2 Floor Over Other Space 2nd Floor ____ ____ 614 ft2 0 0 0 1 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) V1 Gable or Shed Composition shingles 2371 ft2 456 ft2 Medium 0.8 N 0.9 No 0 22.6 ATTIC a I V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC y 1 Full attic Vented 300 2189 ft2 N N __ k{I ! I • I 9/2/2015 3:37 PM EriergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 i FORM R405-2014 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) Main 38 2189 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 38 614 ft2 0.11 Wood WALLS V # Orot Adjacent Space Cavity Width Height Sheathing Framing Solar Below alue Ft In Ft In Area p-value-Eraction..._,9bsor-Grade%_ ✓1 SW Exterior Frame-Wood 2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 ✓2 SW Exterior Frame-Wood Main 19 18 0 10 0 180.0 ft2 0 0.23 0.6 - 0 -73 SE Exterior Frame-Wood 2nd Floor 19 19 7 9 0 176.3 ft2 0 0.23 0.6 0 j 4 SE Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft2 0 0.23 0.6 0 5 NE Exterior Frame-Wood 2nd Floor 19 40 0 8 0 320.0 ft2 0 0.23 0.6 0 I _14 � NE Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.6 0 4 J NW Exterior Frame-Wood 2nd Floor 19 19 7 8 0 156.7 ft2 0 0.23 0.6 0 ✓A NW Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft2 0 0.23 0.6 0 V 9 SW Garage Frame-Wood Main 13 22 0 9 0 198.0 ft2 0 0.23 0.01 0 DOORS V # Ornt Door Type Space Storms U-Value Ft Width In Ft Height Area V/ 1 SW Insulated Main None .6 3 8 24 ft2 1 2 SW Insulated Main None .6 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang • - / # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening V 1 SW 2 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 In Drapes/blinds Interior 5 / 2 SE 4 Vinyl Low-E Double Yes 0.34 0.27 75.0 ft2 1 ft 4 in 1 ft 0 In Drapes/blinds Interior 5 V/` 3 NE 6 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 V J4 'NE 6 Vinyl Low-E Double Yes 0.34 0.27 40.0 ft2 10 ft 0 in 1 ft 0 in Drapes/blinds Interior 5 5 NW 7 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 V 6 NW 8 Vinyl Low-E Double Yes 0.34 0.27 4.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 V / 7 NW 8 Vinyl Low-E Double Yes 0.34 0.27 45.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior.5 t/ / 8 SE 4 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 14 ft 0 In 1 ft 0 in. Drapes/blinds Interior 5 t/l 9 SE 3 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation _ �/ 1 476 ft2 510 ft2 64 ft 9 ft 1 1 I • � I . . • 9/2/2015 3:37 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000311 2284.7 125.43 235.88 .2946 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 36 kBtu/hr 1 sys#1 COOLING SYSTEM V/ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts V/ 1 Central Unit Split SEER: 14 36 kBtu/hr 1080 cfm 0.7 1 sys#1 HOT WATER SYSTEM __V # System Type SubType Location EF Cap Use SetPnt Conservation _ 1 Natural Gas Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage / Cert # Company Name System Model# Collector Model# Area Volume FEF �/ , None None ft2 DUCTS / —Supply— --Return-- Air CFM 25 CFM25 HVAC# V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1/ 1 Attic 6 980 ft2 Attic 520 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling ' 'Jan • 'Feb - 'Mar Apr May Jun Jul Au Sep Heating X Jan X, Feb X Mar Apr May Jun Jul Aug Sep Oct Nov X Dec Venting ,Jan , _Feb X.Mar lxi Apr May Jun �l Jul [ l Aug Sep [X Oct €X�Nov Dec • 9/2/2015 3:37 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 I PM 68 68 68 68 68 68 68 68 68 68 66 66 II Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 i MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1-Electric Heat Pump 0% 1 -Central Unit • • • •4 { I I � I 9/2/2015 3:37 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 1 • FORM R405-2014 PERFORMANCE LEVEL (EPL)ENERGY DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the EnergyPerformance Index, the more efficient the home. 1805 Atlantic Beach Dr. (Lot 42 AB) , Atlantic Beach , FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 3127.90 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 198.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2803.00 ft2 6. Conditioned floor area(ft2) 2803 b.N/A R= ft2 c.N/A R= ft2 7. Windows`* Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.34 284.00 ft2 a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 980 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a.Central Unit 36.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 36.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.223 ft. Area Weighted Average SHGC: 0.270 stems Hot water systems 8. Floor Types Insulation Area 14. Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2189.00 ft2 a.Natural Gas EF:0.6 b.Floor Over Other Space R=0.0 614.00 ft2 b. Conservation features c.N/A - R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ,r.o4.B S...... Construction through the above energy saving features which will be installed (or exceeded) , v, T 0 } ;' `', in this home before final inspection. Otherwise, a new EPL Display Card will be completed � ����� ;;, ,,..r based on installed Code r pli nt features. ;,5"""""..e;; '- -4:. "'0 Builder Signature: r 0 �'L Date: Q!3 i is r �� 5 Address of New Home: gO f v Ii n ue, Rah Dr. City/FL Zip: FL 3223',,,,x}; ��'��` *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/2/2015 3:37 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 ,, FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods I ADDRESS: 1805 Atlantic Beach Dr.(Lot 42 AB) Permit Number. Atlantic Beach ,FL, r MANDATORY REQUIREMENTS See individual code sections for full details. f 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended ' infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. fR402.4.3 Fenestration air leakage.Wlndows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. • i R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handier enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. . 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. i 9/2/2015 3:37 PM EnergyGauge®Ener Gau e®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 i FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) vR403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the • design air flow rate when tested in accordance with ASHRAE 193. R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. iR403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13*C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily / accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ft5 R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies R403.4.4.1 Storage water heater temperature controls o R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). o R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be tumed off.A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water heating systems to be tumed off. VR403.4.4.2 Water heating equipment Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. o R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. if ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a / minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. ,-( R403. Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. `f R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by focal intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the '. calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in i Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the i equipment shall not be less than the calculated latent load. ' 9/2/2015 3:37 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page.2 of 3 src+-.aarrwnnz .-- wn+-+.r. il FORM R405-2014 MANDLTORY REQUIREMENTS - (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This • selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or.heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. O R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. o R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F, o R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be In accordance with ANSI/APSP-14. • o R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. I{ o R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in -i compliance with this equipment. Exceptions: • • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. p R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. / RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently Installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 8404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights R405. Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. • 9/2/2015 3:37 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 - --- • FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cumberland 2803 Left SW Builder Name: Toll Brothers Street: 1805 Atlantic Beach Dr.(Lot 42 AB) Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. / Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and 77/framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. 7: Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be . air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air I barrier installed separating them from the showers and tubs. Electricalphone box on The air barrier shall be installed behind electrical or communication boxes or 7 air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be 7 . sealed to the sub-floor or drywall. :.. An air barrier shall be installed on fireplace walls.Fireplaces shall have / ■ Fireplace gasketed doors (((/// 9/2/2015 3:37 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 i - FLORIDA ENERGY EFFICIENCY CODE F FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method I f Project Name: Cumberland 2803 Left SW Builder Name: Toll Brothers i Street: 1805 Atlantic Beach Dr.(Lot 42 AB) Permit Office: Duval t City,State,Zip: Atlantic Beach ,FL, Permit Number. Design Location: FL,Jacksonville Jurisdiction: 261300 I Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data I I HOUSE PRESSURE I FLOW: I ELA: EqLA: ACH: ACH(50): SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour In Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,If installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, o ........... . F••.,� 1 performance results demonstrate compliance testing shall be conducted by an a^ \'.;,, 4. O F with Florida Energy Code requirements in approved third party.A written to..."'/,�; , „»�,� • accordance with Section R402.4.1.2. report of the results of the test shall .:_-,_,:."�-.-. :V be signed by the third party € �': — a S conducting the test and provided to Lam'- E " 1 9 p .,. s: u SIGNATURE: the code official. i c° PRINTED NAME °°t)w� '*''s I BUILDING OFFICIAL: I DATE: DATE: ----- i I 9/2/2015 3:38 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Softwar Page 1 of 1 I 1 i McGowan , Summary Project Summary ect Job: 1805 ABD Lot 42 AB Date: 9/2/15 Heating&Air Entire House By: Stephen Barber Conditioning " °-• l ` McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey @mcgowansac.com Web:www.mcgowansac.com Pro'ect Information For: Toll Brothers Fl Notes: Cumberland Bonus Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28194 Btuh Structure 20017 Btuh Ducts 3795 Btuh Ducts 4802 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31988 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 25861 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4115 Btuh Ducts 834 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2803 2803 Equipment latent load 4949 Btuh Volume(ft3) 28281 28281 Air changes/hour 0.32 0.16 Equipment total load 30810 Btuh Equiv.AVF(cfm) 151 75 Req.total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB036 Cond CH14NB036 AHRI ref Coil FB4CNP036 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 23800 Btuh Heating output 34000 Btuh @ 47°F Latent cooling 10200 Btuh Temperature rise 27 °F Total cooling 34000 Btuh Actual air flow 1133 cfm Actual air flow 1133 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft 2015-Sep-02 14:20:25 . CA g Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 ..NC\Toll Brothers\Cumberland Bonus 2803 Left.rup Calc=MJ8 Front Door faces:SW /":\ First Floor MAST.E:Fatr 8x4 4° MASTER BEDROOMT ... 10x6 8x4 14x6 .•. 4' 8" " �, 12" 6 x 12 MASTER BATH '"fli12 U ^w�qL %\ " 3"Fan Mal; 18" Ret Riser 3''Fan �;` • 18,, ,4 x 18 .up Riser FAMILY ROOM rJ 3"Fan 12x12 %■1 14" 8" am ' 6x12 6x10 BATH 7" BEDROOM 2; 6 2 IMMIMIMMIU II 1 a HALLWAY '2' 12x6 stairs 7 KITCHEN 12x12 12x6 g" 10x6 7' BEDROOM 3 Ft © ... .5" 10x10 J w a O O a ii cul 10x10 1 "4 9„ '2xG Nill D -ING ROOM 4x14 Del GARAGE 10 x 6 12 x 6 6' J 7 12 x 12 9" LIVING ROOM Job#: 1805 ABD Lot 42 AB McGowan's Heating & Air Conditioning.. Scale: 1 : 102 Performed by Stephen Barber for: Page 1 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.17 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2015-Sep-0214:20:53 www.mcgowansac.com korey @mcgowansac.com ...s\Cumberland Bonus 2803 Left.rup JL Ill up Sup Riser Ret Riser 15" 18" ' 4 x 8 3" Fan 4" bath 3 6x12 8x4 1J8"; 7" 4bed4 . 6x12 10 - .. ^�■r7.... 1 7„ loft' 114x14r�10" • 12" .i Plf 86x10 F, rats_vp1 5. Job #: 1805 ABD Lot 42 AB McGowan's Heating & Air Conditioning., Scale: 1 : 102 Performed by Stephen Barber for: Page2 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.17 RSU12270 H Phone:904-278-0339 Fax:904-278-0366 2015-Sep-02 14:20:53 www.mcgowansac.com korey @mcgowansac.com ...s\Cumberland Bonus 2803 Left.rup McGowan McGowaim Duct System Summary Job: 1805 ABD Lot 42 AB Heating&Ail' Date: 9/2/15 �,,d,�„pny e Entire House By: Stephen Barber ""°� ° " McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.269/0.121 in H2O 0.269/0.121 in H2O Lowest friction rate 0.086 in/100ft 0.086 in/100ft Actual air flow 1133 cfm 1133 cfm Total effective length(TEL) 455 if Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk BATH 2 c 4 0 0 0.117 4.0 Ox 0 VIFx 35.5 195.0 st3 BEDROOM 2 h 1543 55 54 0.118 6.0 Ox 0 VIFx 37.5 190.0 st3 BEDROOM 3 h 2328 82 80 0.108 7.0 Ox 0 VIFx 50.0 200.0 st3 DINING ROOM C 1534 58 70 0.089 7.0 Ox 0 VIFx 58.5 245.0 st4 FAMILY ROOM h 2335 83 67 0.112 7.0 Ox 0 VIFx 39.5 200.0 st5 FAMILY ROOM-A h 2335 83 67 0.123 7.0 Ox 0 VIFx 29.0 190.0 st5 FOYER h 1890 67 58 0.086 6.0 Ox 0 VIFx 67.6 245.0 st4 KITCHEN c 2034 56 93 0.089 7.0 Ox 0 VIFx 55.9 245.0 st4 L mo h 223 8 7 0.172 4.0 Ox 0 VIFx 11.6 145.0 st1 LAUDRY c 791 31 36 0.088 5.0 Ox 0 VIFx 59.8 245.0 st4 LIVING ROOM h 3433 122 96 0.086 7.0 Ox 0 VIFx 68.7 245.0 st4 MASTER BATH c 1229 52 56 0.115 6.0 Ox 0 VIFx 39.0 195.0 st5 MASTER BEDROOM c 2846 124 130 0.119 8.0 Ox 0 VIFx 30.9 195.0 st5 MASTER WIC h 1788 63 29 0.110 4.0 Ox 0 VIFx 44.4 200.0 st5 we c 45 1 2 0.122 4.0 Ox 0 VIFx 29.6 190.0 st5 bath 3 h 477 17 16 0.187 4.0 Ox 0 VIFx 9.1 135.0 st1 bed 4 c 2359 88 108 0.175 7.0 Ox 0 VIFx 13.3 140.0 st1 loft c 3026 110 138 0.184 7.0 Ox 0 VIFx 6.1 140.0 st1 stairs up h 911 32 26 0.174 5.0 Ox 0 VIFx 9.4 145.0 st1 , wrightsoft 2015-Sep-0214:20:25 At. ! 9 Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 ft.A. 1 ...NC1Toll Brothers\Cumberland Bonus 2803 Left.rup Calc=MJ8 Front Door faces:SW 11 Supply Trunk Detail Table ' Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 334 353 0.086 450 12.0 0 x 0 ViniFix st3 st3 Peak AVF 472 488 0.086 456 14.0 0 x 0 VinlFlx st2 st5 Peak AVF 406 350 0.110 517 12.0 0 x 0 ViniFix st2 st1 Peak AVF 256 295 0.172 541 10.0 0 x 0 VinIFIx st2 Peak AVF 877 838 0.086 628 16.0 0 x 0 ViniFix Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb4 Ox 0 251 237 123.4 0.098 320 12.0 Ox 0 VIFx rt3 rb3 Ox 0 323 283 141.4 0.086 926 8.0 Ox 0 VIFx rt3 rb8 Ox 0 142 164 118.1 0.103 302 10.0 Ox 0 VIFx rt1 rb9 Ox 0 113 130 128.6 0.094 295 9.0 Ox 0 VIFx rt1 rb1 Ox 0 303 317 110.9 0.109 404 12.0 Ox 0 VIFx rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt3 Peak AVF 877 838 0.086 497 18.0 0 x 0 VinlFlx rt2 rt1 Peak AVF 256 295 0.094 375 12.0 0 x 0 ViniFix rt2 Peak AVF 877 838 0.086 497 18.0 0 x 0 ViniFix 2015-Sep-02 14:20:25 t " wrightsot Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 A^L.. ...NC\Toll Brothers\Cumberland Bonus 2803 Left.rup Calc=MJ8 Front Door faces:SW • MCG+o'wan's Manual S Compliance Report Job: Lot 42 Date: 912/15 coniioning Entire House By: Stephen Barber Heating at�ifitrio.. �j "" �° McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 24975 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 4235 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 29210 Btuh Indoor RH: 50% Estimated airflow: 1100 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0360000A+FB4CNP036L Actual airflow: 1100 cfm Sensible capacity: 26024 Btuh 104%of load Latent capacity: 4235 Btuh 100%of load Total capacity: 30259 Btuh 104%of load SHR: 86% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 26952 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0360000A+FB4CNP036L Actual airflow: 1100 cfm Output capacity: 33000 Btuh 122%of load Capacity balance: 27 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1100 cfm Output capacity: 7.9 kW 100%of load Temp.rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. ti wrightsoft 2015-Sep-02 14:28:58 1 ,��j�'� � Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 �'+� K l:1300 RES NC1Toll Brothers\3 TON Manual S.rup Calc=MJ8 House faces:SW