Loading...
394 8th ST - REVISION / REVISED TRUSS F-S -L\l� ' `�` J" CITY OF ATLANTIC BEACH s1 800 Seminole Road 10 ' ) OFFICE COPY Atlantic Beach,Florida 32233 Telephone(904)247-5800 FAX(904)247-5845 Di31�r> REVISION REQUEST SHEET Date: t06\ Cc/p i5 Received by: Resubmitted: Permit Number: \c _ S F0.- ‘S q u Original Plans Examiner: St,Y\ AC\Z,17ko`n Project Name: %C\ h104,:\ R e S■ .e"f\■,'t. Project Address: .. 0•.\,\ 2k.-2-' ST.N.e@ \- _INA.Ack\k\c, C3ea.,ti FL , 13-4,13-\ Contractor: 'Ck∎NiQ�S\ 'o Yee S Contact Name: S .■ c,„\ 0' \e \\ Contact Phone : b‘,\ - 'a,\u- \\g(N`\ Contact e-mail: ro.e\\ Q. ,r.yr;v e%5 .-c\ ov-6.(o ■ Revision/Plan Check/Permit Fee(s)Due: $ Description of Proposed Revision to Existing Permit: rp.N,ec w0,0'. \:\E.? 1A-t[ Q S v -2/\in ll a-Nk6 5 c..,1,‘ R.K\e vSC aS N- • MCC QC-It'c :n_ \■ .v O t V Ir.' \--Vt).O Cx v∎ c Z 05W N.A./2k pv\ 4-Nest \6\_ �cu..n..t� .,,,o.,\. !�:\te trO r& )rr•>s c d\cicaf:.w.q� 2■Y '1.2.- , ')air \^ow.o..a 1S \cmov5e Ln C 'n\SQi\\-.orv.‘‘- Cvv 0._ %OS -Oh \i' ■c)r Additional Increase in Building Value: $ ci Additional S.F. Site Plan Revised: Public W/U Approval: • By signing below.I(print na . Zxxc. 4\ \/*-, \ _ affirm that the above revision is inclusive of the proposed - - es. _ /-2,,v- 404- 657- Pkg"k ` 07 6(\.5 Si: ature • Contractor/Agent(contrac . •, -. •, .. •, Date Office Use Only t5 U �'! 'E i Date: /0'e?O-/ ( Approved: X v Rejected: Notified by: , OCT 1 -6--2015 Plan Review Comments: Lt �y as /Y �Pl�d 1 cad� L?a(F V vrr r Department review required Yes No Building fly, Planning &Zoning Tree Administrator Plans Examiner Public Works Public Utilities /0 -€O Public Safety Fire Services Date Created 8/20/IS Rev.2 OFFICE COPY AP ESC T E C H N O L O G Y MEMORANDUM REVISION October 16, 2015 6P# /s- sr e- is 9k DATE /U / 2 1,__ TO: Riverside Homes SIGNED FR: Derek B. Murray, P.E. RE: Sherry Terrace, Lot 6 (Brighton Residence) Apex#RS2364 The purpose of this memorandum is to address the following framing issues: 1) As we understand, the framer would like to use 7/16"24/16 span rated OSB or plywood as the roof deck sheathing in lieu of the 5/8"40/20 span rated OSB or plywood specified for shingle and metal roof in Table 2: Wood Structural Panel Sheathing Requirements on structural sheet ST-2. We have reviewed the anticipated loading and conclude that this is an acceptable alternative in this case. 2) Gable truss GE04 cannot be located as specified on plan due to an existing tree on the lot, and the framer would like to move the truss approximately 24"back towards the house and conventionally frame a Boston hip. Please see the attached addendum"Gable Framing Addendum at Balcony" and truss repair for GE04. Should you have any further questions or require any further clarification, please call. �. :M MU • • Ito sQ�Ci CAE N S E • • O;' O 7" • jgl!?ray,P.E FL PE#71457 10/16/15 4745 Sutton Park Court,Suite 402 Jacksonville, FL 32224 Phone 904-821-5200 Fax 904-992-8700 FBPE CA 7547 THIS REVISION IS IN CONJUNCTION WITH ENGINEERING DRAWINGS BY APEX TECHNOLOGY. APEX JOB NUMBER RS2364 OFFICE COPY Ih KEY MAP (3)2x12 (3)2x12 `o --•6x6 NO.2 SYP PT POST,(3)TOTAL •BEAM TO POST W/(2)MSTA24 •POST TO POST BELOW W/(2)MSTA36 SECOND LEVEL STRUCTURAL FRAMING PLAN T08 C T08 GE04- •CONVENTIONALLY FRAMED RAFTERS— TO \ ' BE 2x6 NO.2 SYP,MAX 24"O.C. 2x6 NO.2 SYP ROOF LEDGER, •FASTEN TO LEDGER AND BEAM W/(4) FASTEN TO EACH GABLE TRUSS 10d TOE-NAILS MEMBER W/(4)12d COMMON @ MAX 24"O.C. SECOND LEVEL ROOF FRAMING PLAN stool Ii,,,,f ass B R MODIFIED BY APEX TECHNOLOGY ti ° 714 7 ••::* RIVERSIDE HOMES = * • °C' A PEXSHERRY TERRACE 6 (BRIGHTON RESIDENCE �oti,� s :��'�� GABLE FRAMING ADDENDUM AT BALCONY 'r,'�1'••� ,•il`.���c".,`~ TECHNOLOGY ;,s10-146\-01%5 APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC..A FLORIDA CORPORATION FLORIDA ENGINEER BUSINESS NO.7547-4745 SUTTON PARK COURT SUITE 402.JACKS674 LE.FL .32224-906.021.5200 BRIGHTON Ply:1 SEQN: 17224/T60/GABL BRIGHTON Qty: 1 FROM: DRW: GE04 REPAIR Wgt:247.8 lbs Page 1 of 2 ... / ... 10/16/15 RIVERSIDE HOMES BRIGHTON RESIDENCE tCE COPY REPAIR:SHIFT GABLE 24"AND ATTACHO`C f K�5%5 ti BOSTON HIP pxe� 0�axa NO FURTHER REPAIR REQUIRED /I, I - M "=4X10' �_ N,3x/XH /4X80 D1 4X8 P 9p F 04X8 4111 - I4X8(E5) (E5) 4X81E5) .�I'' 16,, "-T.- �11 g _ . . AE AD AC AB AA Z V X W V 1254 • • (NNL) (NNL) I-3'4'8- 4 F. 3'418-.4 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl1CSI Criteria •Maximum Reactions(Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.092 AC 999 313 B 1795 /564 /458 /- /248 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.194 X 999 313 T 1795 /564 /458 /- /- /5.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.042 V - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:B HORZ(TL): 0.092 I - - B Min Brg Width Req= 2.1 NCBCLL: 10.00 Mean Height:26.49 ft Code/Misc Criteria Creep Factor:1.5 T Min Brg Width Req= 2.1 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.441 Bearings B&T Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.965 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.576 Maximum Top Chord Forces Per Ply(Ibs)C&C Dist a:3.00 ft FTIRT:30(0)!10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 -15 K-L 249 -764 Wind Duration:1.60 WAVE VIEW Ver:15.01.02F.0923.22 B-C 498 -1572 L-M 522 -1658 Lumber Purlins B-D 293 -953 M-N 529 -1693 C-D 498-1572 N-O 544 -1726 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins D-E 762 -2459 O-P 663 -2122 Top chord 2x4 SP#2 to laterally brace chords as follows: E-F 683 -2170 P-Q 683 -2170 Bot chord 2x4 SP#2 Chord Spacing(in oc) Start(ft) End(ft) F-G 663 -2122 Q-R 762 -2459 Webs 2x4 SP#3 TC 24 -1.29 27.37 :Stack Chord SC1 2x4 SP#2: BC 91 0.00 26.08 G-H 544 -1726 R-S 498 -1572 :Stack Chord SC2 2x4 SP#2: Apply purlins to any chords above or below fillers H-I 529-1683 R-T 293 -953 :Lt Slider 2x4 SP#3:BLOCK LENGTH= 1.500' at 24"OC unless shown otherwise above. I-J 522 -1658 S-T 498 -1572 :Rt Slider 2x4 SP#3:BLOCK LENGTH= 1.500' J-K 249 -764 T-U 42 -15 Additional Notes Lumber value set"136°uses design values See DWGS A14030ENC101014&GBLLETIN1014 for approved 1/30/2013 by ALSC Maximum Bot Chord Forces Per Ply(Ibs) gable wind bracing requirements. Chords Tens.Comp. Chords Tens. Comp. Special Loads Stacked top chord must NOT be notched or cut in B-AE 2025 -629 Z-Y 1341 412 (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) area(NNL).Dropped top chord braced at 24"o.c. TC-From 58 plf at -1.38 to 58 plf at 1.82 intervals.Attach stacked top chord(SC)to dropped AE-AD 2014 -627 Y-X 1670 -521 TC-From 58 plf at 1.82 to 58 plf at 7.97 top chord in notchable area using 3x4 tie-plates 24" AD-AC 1670 -521 X-W 1670 -521 TC-From 58 plf at 7.97 to 58 plf at 13.04 o.c.Center plate on stacked/dropped chord AC-AB 1670 -521 W-V 2014 -627 TC-From 57 pff at 13.04 to 57 plf at 18.11 interface,plate length perpendicular to chord length. AB-AA 1341 -412 V-T 2025 -629 TC-From 57 plf at 18.11 to 57 plf at 26.08 Splice top chord in notchable area using 3x6. AA-Z 1341 -412 TC-From 57 pff at 26.08 to 57 plf at 27.46 The overall height of this truss excluding overhang is BC-From 5 plf at -1.38 to 5 plf at 0.00 10-1-10. Maximum Web Forces Per Ply(lbs) BC-From 74 pff at 0.00 to 74 pff at 12.00 Webs Tens.Comp. Webs Tens. Comp. BC-From 74 Of at 12.00 to 74 ptf at 26.08 BC-From 5 pff at 26.08 to 5 Of at 27.46 E-AF 115 -375 AK-L 257 -842 AF-AD 128 -389 AK-AM 72 -88 Plating Notes G-AG 178 -583 AL-Z 83 -9 All plates are 3X3 except as noted. AC-AH 60 -20 AL-Y 76 -114 Plates sized for a minimum of 4.00 sq.in./piece. AH-AB 186 -616 AL-AN 54 -46 AB-AL 76 -114 Y-AO 186 -617 Wind Al-AK 72 -88 AO-X 60 -20 Wind loads based on MWFRS with additional C&C AJ-AL 54 -46 AP-0 178 -583 member design. J-AK 257 -842 W-AQ 127 -389 K-AK 805 -245 AQ-Q 115 -375 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APE X Michael G Kozlowski Jeffrey P Arneson Derek B Murray iiiSCEMEM PE No.60839 PE No.58544 PE No.71457 BRIGHTON Ply:1 SEQN:17224/T60/GABL BRIGHTON Qty: 1 FROM: DRW: GEO4'REPAIR Wgt:247.8 lbs Page 2 of 2 ... / ... 10/16/15 Maximum Gable Forces Per Ply(lbs) Gables Tens.Comp. Gables Tens. Comp. Cv AE-E 195 -24 L-AM 764 -215 �,�� OP 1 F-AF 29 -31 AM-AN 763 -215 OfOFV AD-G 509 -135 AN-Y 753 -212 AG-I 46 -47 M-AP 46 -47 Al-AJ 763 -215 O-W 509 -135 Al-J 764 -215 AQ-P 29 -31 AJ-AB 753 -212 Q-V 195 -24 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APE X Michael G Kozlowski Jeffrey P Arneson Derek B Murray iiiirMing PE No.60839 PE No.58544 PE No.71457 JOB COPY THIS PLAN MUST BE Ap EX ON JOB SITE FOR TECHNOLOGY EACH INSPECTION MEMORANDUM October 16, 2015 REVISION TO: Riverside Homes BP# $ FR: Derek B. Murray,P.E. DATE RE: Sherry Terrace, Lot 6 (Brighton Residence) SIGNED-z=�•� ��' " Apex#RS2364 The purpose of this memorandum is to address the following framing issues: 1) As we understand, the framer would like to use 7/16"24/16 span rated OSB or plywood as the roof deck sheathing in lieu of the 5/8"40/20 span rated OSB or plywood specified for shingle and metal roof in Table 2: Wood Structural Panel Sheathing Requirements on structural sheet ST-2. We have reviewed the anticipated loading and conclude that this is an acceptable alternative in this case. 2) Gable truss GE04 cannot be located as specified on plan due to an existing tree on the lot, and the framer would like to move the truss approximately 24"back towards the house and conventionally frame a Boston hip. Please see the attached addendum "Gable Framing Addendum at Balcony" and truss repair for GE04. Should you have any further questions or require any further clarification,please call. ,,0".; Mr t U- �, 4,��Q� GE N S ,'��i . Q:• 1457 •*0 .. • . rt �10 ;• S 0 C,1\; °O. • .• � �� gt1141l}ray,P.E FL PE#71457 10/16/15 4745 Sutton Park Court,Suite 402 Jacksonville,FL 32224 Phone 904-821-5200 Fax 904-992-8700 FBPE CA 7547 THIS REVISION IS IN CONJUNCTION WITH I , IIG'�i ENGINEERING DRAWINGS BY APEX TECHNOLOGY. -�-.1 i APEX JOB NUMBER RS2364 v 1 Ir I. 71 'i ril f -1 c _lj � - _ - ,, r i IL — — KEY MAP s is (3'2x12 (3)2x12 i O. •6x6 NO.2 SYP PT POST,(3)TOTAL •BEAM TO POST W/(2)MSTA24 •POST TO POST BELOW W/(2)MSTA36 SECOND LEVEL STRUCTURAL FRAMING PLAN T08 =__I_. -- _ i ; i /I I — - •CONVENTIONALLY FRAMED RAFTERS TO BE 2x6 NO.2 SYP,MAX 24"O.C. 2x6 NO.2 SYP ROOF LEDGER, •FASTEN TO LEDGER AND BEAM W/(4) FASTEN TO EACH GABLE TRUSS 10d TOENAILS MEMBER W/(4)12d COMMON @ MAX 24"O.C. SECOND LEVEL ROOF FRAMING PLAN - ,,,,,,1 u„,,,,, r O MODIFIED BY APEX TECHNOLOGY .. :� 0 7�Q'� ':* RIVERSIDE HOMES * °cc SHERRY TERRACE 6 (BRIGHTON RESIDENCES% S ' 4;••.41,•APE GABLE FRAMING ADDENDUM AT BALCONY `�•`�, °-•� `..•°"..._\C"4," TECHNOLOGY ,d'f•i'SYtQ,}ti/jatt 6� ►'}�5 APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC..A FLORIDA CORPORATION FLORIDA ENGINEER BUSINESS NO.7547-4745 SUTTON PARK COURT SUITE 402.JACKSONNLtE.�L 32224-904.821.5200 BRIGHTON Ply:1 SEAN:17224/T60/GABL BRIGHTON Qty: 1 FROM: DRW: GE04_REPAIR Wgt:247.8 Ibs Page 1 of 2 ... / ... 10/16/15 RIVERSIDE HOMES BRIGHTON RESIDENCE REPAIR:SHIFT GABLE 24"AND ATTACH %a5x5 BOSTON HIP. /4X8 L\axe NO FURTHER REPAIR REQUIRED. �' c4X10 / N\3X4 12 /4X80 41I .Sx7 om- ,` R 324X8(ES) 14X8(E5) 4 =17 4 X 2X4 4 e T 2X4 AD 4 7 c 2 cVX 4 c4 5 2X4 AE AD AC AB PA 2 21 V X IA/ V Imb • • (NNL) (NNL) I.--3'4.8--I I.-3'4113--1 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria •Maximum Reactions(Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.092 AC 999 313 g 1795 /564 /458 /_ /248 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.194 X 999 313 T 1795 /564 /458 /- 1- /5.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.042 V - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:B HORZ(TL): 0.092 I - - B Min Brg Width Req= 2.1 NCBCLL: 10.00 Mean Height:26.49 ft Code/Misc Criteria Creep Factor:1.5 T Min Brg Width Req= 2.1 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.441 Bearings B&T Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.965 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.576 Maximum Top Chord Forces Per Ply(Ibs) C&C Dist a:3.00 ft FT/RT:30(0)110(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 -15 K-L 249 -764 Wind Duration:1.60 WAVE VIEW Ver:15.01.02F.0923.22 B-C 498-1572 L-M 522 -1658 Lumber Purlins B-D 293 -953 M-N 529 -1693 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins C-D 498-1572 N-O 544 -1726 to laterally brace chords as follows: D-E 762 -2459 O-P 663 -2122 Top chord 2x4 SP#2 Chord y S Start(ft) End(ft) -F 683-2170 P-Q 683 -2170 Spacing(in oc) Start Bet chord 2x4 SP#2 ft) End ft) F G 663-2122 Q R 762 2459 Webs 2x4 SP#3 TC 24 1.29 27.37 :Stack Chord SC1 2x4 SP#2: BC 91 0.00 26.08 G-H 544-1726 R-S 498 -1572 :Stack Chord SC2 2x4 SP#2: Apply purlins to any chords above or below fillers H-I 529-1693 R-T 293 -953 :Lt Slider 2x4 SP#3:BLOCK LENGTH= 1.500' at 24"OC unless shown otherwise above. I-J 522 -1668 S-T 498 -1572 :Rt Slider 2x4 SP#3:BLOCK LENGTH= 1.500' J-K 249 -764 T-U 42 -15 Additional Notes Lumber value set"13B"uses design values See DWGS Al 030ENC101014&GBLLETIN1014 for approved 1/30/2013 by ALSC Maximum Bot Chord Forces Per Ply(Ibs) gable wind bracing requirements. Chords Tens.Comp. Chords Tens. Comp. Special Loads Stacked top chord must NOT be notched or cut in (Lumber Dur.Fac.=1.25/Plate Dur.Fac=1.25) area(NNL).Dropped top chord braced at 24"o.c. B-AE 2025 -629 Z-Y 1341 -412 TC-From 58 plf at -1.38 to 58 pff at 1.82 intervals.Attach stacked top chord(SC)to dropped AE-AD 2014 -627 Y-X 1670 -521 TC-From 58 pff at 1.82 to 58 plf at 7.97 top chord in notchable area using 3x4 tie-plates 24" AD-AC 1670 -521 X-W 1670 -521 TC-From 58 plf at 7.97 to 58 plf at 13.04 o.c.Center plate on stacked/dropped chord AC-AB 1670 -521 W-V 2014 -627 TC-From 57 plf at 13.04 to 57 plf at 18.11 interface,plate length perpendicular to chord length. AB-AA 1341 -412 V-T 2025 -629 TC-From 57 plf at 18.11 to 57 plf at 26.08 Splice top chord in notchable area using 3x6. AA-Z 1341 -412 TC-From 57 plf at 26.08 to 57 plf at 27.46 The overall height of this truss excluding overhang is BC-From 5 pff at -1.38 to 5 plf at 0.00 10-1-10. Maximum Web Forces Per Ply(Ibs) BC-From 74 plf at 0.00 to 74 pff at 12.00 BC-From 74 plf at 12.00 to 74 pff at 26.08 Webs Tens.Comp. Webs Tens. Comp. BC-From 5 Of at 26.08 to 5 pff at 27.46 E-AF 115 -375 AK-L 257 -842 Plating Notes AF-AD 128 -389 AK-AM 72 -88 G-AG 178 -583 AL-Z 83 -9 All plates are 3X3 except as noted. AC-AH 60 -20 AL-Y 76 -114 Plates sized for a minimum of 4.00 sq.inJpiece. AH-AB 186 -616 AL-AN 54 -46 AB-AL 76 -114 Y-AO 186 -617 Wind Al-AK 72 -88 AO-X 60 -20 Wind loads based on MWFRS with additional C&C AJ-AL 54 -46 AP-0 178 -583 member design. J-AK 257 -842 W-AQ 127 -389 K-AK 805 -245 AQ-Q 115 -375 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ez; Michael G Kozlowski Jeffrey P Ameson Derek B Murray PE No.60839 PE No.58544 PE No.71457 BRIGHTON Ply:1 SEAN:17224/T60/GABL BRIGHTON Qty: 1 FROM: DRW: GC04_REPAIR Wgt:247.8 Ibs Page 2 of 2 ... / ... 10/16/15 Maximum Gable Forces Per Ply(Ibs) Gables Tens.Comp. Gables Tens. Comp. AE-E 195 -24 L-AM 764 -215 F-AF 29 -31 AM-AN 763 -215 AD-G 509 -135 AN-Y 753 -212 AG-I 46 -47 M-AP 46 -47 AI-AJ 763 -215 O-W 509 -135 AI-J 764 -215 AQ-P 29 -31 AJ-AB 753 -212 Q-V 195 -24 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Ap E X Michael G Kozlowski Jeffrey P Arneson Derek B Murray PE No.60839 PE No.58544 PE No.71457