1588 OCEAN BLVD - ENERGY SHEETS FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1588 Ocean Blvd Builder Name: Ossie Homes and Development Street: 1588 Ocean Blvd Permit Office: City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS 1. New construction or existing New(From Plans) 9. Wall Types(4217.1 sqft.) Insulation Area a.Frame 2. Single family or multiple family Single-family Wood,Exterior R=19.0 1967.00 ft2 b. Frame-Wood,Exterior R=13.0 1849.30 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 400.75 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2618.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2618.00 ft2 6. Conditioned floor area above grade(ft2) 3894 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(517.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 501.4 a. U-Factor Dbl,U=0.33 517.00 ft2 b.Sup. Attic,Ret:Attic,AH:Second Floor 6 277.4 SHGC: SHGC=0.23 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 33.2 SEER:15.00 b.Central Unit 22.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 33.0 HSPF:8.90 SHGC: b. Electric Heat Pump 22.0 HSPF:8.50 Area Weighted Average Overhang Depth: 3.461 ft. Area Weighted Average SHGC: 0.230 14.Hot water systems 8. Floor Types (3894.0 sqft Insulation Area a.Natural Gas Tankless Cap:1 gallons.) EF:0..800 0 a.Slab-On-Grade Edge Insulation R=0.0 2507.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1276.00 ft2 None c.other(see details) R= 111.00 ft2 15.Credits Pstat Glass/Floor Area: 0.133 Total Proposed Modified Loads: 85.99 PASS Total Baseline Loads: 96.67 I hereby certify that the plans and specifications covered by Review of the plans and -'',T> $r.4� this calculation are in corn.'. .- w' the Florida Energy specifications covered by this ,: 0 McOrp'•., Code. calculation indicates compliance of with the Florida Energy Code. ;ti S ,,r PREPARED BY: Before construction is completed DATE: __ ZINErigrAr this building will be inspected for 0' �t® compliance with Section 553.908 \ . 47,-_,,, e ;`I hereby certify tha building,as designed,is in compliance Florida Statutes. % with the Florida Energy Code. •oD WE OWNER/AGENT: BUILDING OFFICIAL: in',r^ __ DATE: DATE: Q-. . (T''o7 LS_ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. r'"_ COPY 9/8/2015 11:31 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 , FORM R405-2014 PROJECT Title: 1588 Ocean Blvd Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 3894 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Ossie Homes and Developme Rotate Angle: 0 Street: 1588 Ocean Blvd Permit Office: Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT_NS FL_MAYPORT_NS 2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 Blockl 2507 26323.5 2 Block2 1387 13176.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms !nil!ID Finished Cooled Heated 1 First Floor 2507 26323.5 Yes 3 2 1 Yes Yes Yes 2 Second Floor 1387 13176.5 No 3 3 1 Yes Yes Yes FLOORS ✓ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio First Floor 182 ft 0 2507 ft2 ---- 1 0 0 2 Raised Floor Second Floor ____ ____ 111 ft2 19 1 0 0 3 Floor Over Other Space Second Floor ____ 1276 ft2 0 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2836 ft2 0 ft2 Medium 0.75 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2618 ft2 N N 9/8/2015 11:31 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 ill FORM R405-2014 CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) First Floor 30 1231 ft2 0.11 Wood 2 Under Attic(Vented) Second Floor 30 1387 ft2 0.11 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V # Ornt--- ----To Wail Type 5 R-Value Ft - In Ft In Area R-Value Fraction Absor. Grade% 1 E Exterior Frame-Wood First Floor 19 36.5 10 6 383.3 ft2 0.23 0.75 0 _ 2 N Exterior Frame-Wood First Floor 19 55 8 10 6 584.5 ft2 0.23 0.75 0 _ 3 W Exterior Frame-Wood First Floor 19 34 6 10 6 362.3 ft2 0.23 0.75 0 4 W Exterior Frame-Wood First Floor 19 7 10 10 6 82.3 ft2 0.23 0.75 0 5 W Exterior Frame-Wood First Floor 19 16 8 10 6 175.0 ft2 0.23 0.75 0 6 W Exterior Frame-Wood First Floor 19 36 2 10 6 379.8 ft2 0.23 0.75 0 7 E Garage Frame-Wood First Floor 13 22 6 10 6 236.3 ft2 0.23 0.75 0 8 S Garage Frame-Wood First Floor 13 15 8 10 6 164.5 ft2 0.23 0.75 0 9 E Exterior Frame-Wood Second Floor 13 53 8 9 6 509.8 ft2 0.23 0.75 0 10 N Exterior Frame-Wood Second Floor 13 43 8 9 6 414.8 ft2 0.23 0.75 0 11 W Exterior Frame-Wood Second Floor 13 53 8 9 6 509.8 ft2 0.23 0.75 0 12 S Exterior Frame-Wood Second Floor 13 43 8 9 6 414.8 ft2 0.23 0.75 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood First Floor None .46 6 8 48 ft2 2 E Wood First Floor None .46 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening . 1 E 1 Vinyl Low-E Double Yes 0.33 0.23 36.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds Exterior 5 2 N 2 Vinyl Low-E Double Yes 0.33 0.23 36.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds Exterior 5 3 N 2 Vinyl Low-E Double Yes 0.33 0.23 16.0 ft2 1 ft 6 in 3 ft 0 in Drapes/blinds Exterior 5 4 N 2 Vinyl Low-E Double Yes 0.33 0.23 12.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds Exterior 5 5 W 3 Vinyl Low-E Double Yes 0.33 0.23 96.0 ft2 8 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 6 W 3 Vinyl Low-E Double Yes 0.33 0.23 36.0 ft2 8 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 7 W 4 Vinyl Low-E Double Yes 0.33 0.23 24.0 ft2 8 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 8 W 5 Vinyl Low-E Double Yes 0.33 0.23 36.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds Exterior 5 9 E 9 Vinyl Low-E Double Yes 0.33 0.23 16.0 ft2 1 ft 6 in 1 ft 0 in Drapes/blinds Exterior 5 10 E 9 Vinyl Low-E Double Yes 0.33 0.23 54.0 ft2 1 ft 6 in 0 ft 6 in Drapes/blinds Exterior 5 11 N 10 Vinyl Low-E Double Yes 0.33 0.23 10.0 ft2 1 ft 6 in 1 ft 0 in Drapes/blinds Exterior 5 12 N 10 Vinyl Low-E Double Yes 0.33 0.23 36.0 ft2 1 ft 6 in 0 ft 6 in Drapes/blinds Exterior 5 13 W 11 Vinyl Low-E Double Yes 0.33 0.23 45.0 ft2 1 ft 6 in 0 ft 6 in Drapes/blinds Exterior 5 14 W 11 Vinyl Low-E Double Yes 0.33 0.23 24.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds Exterior 5 15 S 12 Vinyl Low-E Double Yes 0.33 0.23 30.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds Exterior 5 16 S 12 Vinyl Low-E Double Yes 0.33 0.23 10.0 ft2 1 ft 6 in 1 ft 0 in Drapes/blinds Exterior 5 9/8/2015 11:31 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 GARAGE # Floor Area __ Ceiling Area Exposed Wall Perimeter Avg.Wall Height _ Exposed Wall Insulation 1 475.072 ft' 384 ft2 43 ft 10.5 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 - 1 Wholehouse Proposed ACH(50) .000322 3291.7 180.71 339.85 .3055 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.9 33 kBtu/hr 1 sysll 2 Electric Heat Pump Split HSPF:8.5 22 kBtu/hr 2 sys#2 COOLING SYSTEM V it System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 33.2 kBtu/hr 1250 cfm 0.85 1 sysll 2 Central Unit Split SEER:15 22.8 kBtuTr 850 cfm 0.85 2 sys#2 HOT WATER SYSTEM V . # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.8 1 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert U Company Name System Model# Collector Model# Area Volume FEF • None None ft2 DUCTS V Supply---- ---Return---- Air CFM 25 CFM25 HVAC# ;f Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 501.4 ft Attic 125.4 ft Default Leakage Garage (Default) (Default) 1 1 2 Attic 6 277.4 ft Attic 69.4 ft2 Default Leakage Second Flo (Default) (Default) 2 2 9/8/2015 11:31 AM EnergyGauge®USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin IXIJJ:ril Feb ( Mar (( A r Ma X Jun X Jul X Au X Se Oct Nov Dec Venting X}Feb [XI Mar lX]Apr May Jun Jul Aug Sep �XI Oct �XX Nov Deecc Venting Jan [[ 1 Feb [X Mar l Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/8/2015 11:31 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 • FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index,the more efficient the home. 1588 Ocean Blvd, Atlantic Beach, FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 1967.00 ft� b.Frame-Wood,Exterior R=13.0 1849.30 ft 3. Number of units,if multiple family 1 c. Frame-Wood,Adjacent R=13.0 400.75 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 2618.00 ft2 6. Conditioned floor area(ft2) 3894 b.N/A R= ft2 7. Windows" Description Area C.N/A R= ft s a. U-Factor Dbl,U=0.33 517.00 ft2 11.Ducts R ft a.Sup:Attic,Ret:Attic,AH:Garage 6 501.4 SHGC: SHGC=0.23 b.Sup: Attic, Ret:Attic,AH:Second Floor 6 277.4 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 33.2 SEER:15.00 SHGC: b.Central Unit 22.8 SEER:15.00 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 33.0 HSPF:8.90 Area Weighted Average Overhang Depth: 3.461 ft. b.Electric Heat Pump 22.0 HSPF:8.50 Area Weighted Average SHGC: 0.230 8. Floor Types Insulation Area 14.Hot water systems Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2507.00 ft2 a.Natural Gas p EF:0.8 b.Floor Over Other Space R4.0 1276.00 ft2 c.other(see details) R= 111.00 ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building VEST .' Construction through the above energy saving features which will be installed (or exceeded) 01 .......... ATE in this home before final ins,_., io Otherwise, a new EPL Display Card will be completed y�i3 .-', ',., ` ,.. based on installed Code ►• •li features. //,? ;„1,/,',/t''‘, . -•r':••,3∎`.p� . a '.-4.,, . �-..-.,..- 0 Builder Signature: €.--1 Date: Q 6;15, 1t) _c. a Address of New Hoy /5a-S- 0e-- �i1/ 04A City/FL ip: L `' J *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/8/2015 11:32 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 • FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 1588 Ocean Blvd Builder Name: Ossie Homes and Development Street: 1588 Ocean Blvd Permit Office: City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. (/ Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. ✓ Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity ✓ spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be l•/! air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or /17 air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. ✓✓✓ Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 9/8/2015 11:32 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 ? =."3,,,,,,,,,t,§ ;1E4 : �`h ] !-k| ! ! na ) S §i§ R `f� -- ®/ § #&f ['''E. . ' / { ) J f !• E : I - / \ \i 4t® I �� £ a , . . _ o! ——, .. / / �] J}_ I ` Ea ; } ) \ ( ' \k3\k Li � : . b . f 2/§) § • . , . k � i . {\ 1 ){2 _ ■ , i | KIM F � i 77 k ! k 9 _ . . . i . k ! f i } } { � _ : �� a ,6 . * ® ..... ...... ! ]; �6E � � --- -2 ' &2 ¥ � / \ .� \ .- f)g ! 9I I 2 `, ■ 3 /§ ■ 7 0 ft e/\ ) \ }\ik = ) f! ! / !' !— ; ) ''=} !k i I . ».4` . 1— 'k o 2 b .._r•T zo 7Ipi — cITI-h ito,*z v„,..... w ? g g 'E U -I --J 2 g % _____..j...-- ............... m V•cro cn m 7 o c 2n - (..) E= T., ._. 0 s 2 ii. - g -L ___-____ iiL x 0. 0 i . ..... t 2 R ■--... g E , 2: . .00.. ',...! .., ‘r e r--—1 I .. . . A., IS I i r" a i 6- ii 13 F. a • E g"; 1 -, 0 1 - 1 t m ij a , o i d' i o 1 , ette Op 1 a , o ,IIF -IL , A . E' - o 2 ; z ____.u................p j E A 2 i tn ., 9 2:1.1 .9111 i?.SM.i. 4' Le 08 3 n 5 ELO E§ ,•■ 4- ic • Manual S Compliance Report Job: 1588 Ocean Blvd Date: 09107!2015 1st Floor System By: David C Brown "2f 'f ConsultAir, LLC Atlantic Beach,Fl 32233 Phone (904)402-1463 Fax (904)800-1222 Web www.LoadCalculations.corn Project Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32223 Cooling Equipment Design Conditions Outdoor design DB: 92.1°F Sensible gain: 27843 Btuh Entering coil DB: 77.5°F Outdoor design WB: 77.6°F Latent gain: 4591 Btuh Entering coil WB: 63.7°F Indoor design DB: 75.0°F Total gain: 32434 Btuh Indoor RH: 50% Estimated airflow: 1250 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Amana Model: ASZ140361B*+AVPTC313714A* Actual airflow: 1250 cfm Sensible capacity: 28529 Btuh 102% of load Latent capacity: 4636 Btuh 101% of load Total capacity: 33165 Btuh 102% of load SHR: 86% Heating Equipment Design Conditions Outdoor design DB: 38.6°F Heat loss: 27996 Btuh Entering coil DB: 69.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Amana Model: ASZ140361B*+AVPTC313714A* Actual airflow: 1250 cfm Output capacity: 34800 Btuh 124% of load Capacity balance: 35 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1250 cfm Output capacity: 8.0 kW 97%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. wri htsoft' 2015-Sep-08 1142 43 ^_ 9 Right-Suite®Universal 2015 15 RSU15431 Page 1 CK Development 1588 Ocean Blvd\1588 Ocean Blvd rup Calc=MJ8 Front Door(aces. E • Manual S Compliance Report Job: 1588 Ocean Blvd Date: 09/0712015 2nd Floor System By: David C Brown VP:del viat'�"` ConsultAir, LLC Atlantic Beach,FI 32233 Phone(904)402-1463 Fax (904)800-1222 Web:www LoadCalculations com Project Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32223 Cooling Equipment Design Conditions Outdoor design DB: 92.1°F Sensible gain: 19087 Btuh Entering coil DB: 77.2°F Outdoor design WB: 77.6°F Latent gain: 3290 Btuh Entering coil WB: 63.6°F Indoor design DB: 75.0°F Total gain: 22376 Btuh Indoor RH: 50% Estimated airflow: 850 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Amana Model: ASZ140241A*+AVPTC313714A° Actual airflow: 850 cfm Sensible capacity: 19022 Btuh 100% of load Latent capacity: 3743 Btuh 114% of load Total capacity: 22765 Btuh 102% of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 38.6°F Heat loss: 15611 Btuh Entering coil DB: 69.2°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Amana Model: ASZ140241A`+AVPTC313714A* Actual airflow: 850 cfm Output capacity: 24000 Btuh 154% of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 850 cfm Output capacity: 4.6 kW 100%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. Wrl htsoft' 2015-Sep-08114243 �_ 9 Right-SuiteV Universal 2015 15.0.19 RSU15431 Page 2 ACC Development\1588 Ocean Blvd\1588 Ocean Blvd.rup Calc=MJ8 Front Door faces. E Project Summary Job: 0587/2015 Blvd J Summary Date: 0910712015 geaver Entire House By: David C Brown ConsultAir, LLC Atlantic Beach,Fl 32233 Phone (904)402-1463 Fax (904)800-1222 Web.www LoadCalculations.com Pro.ect Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32223 Notes: Desi. n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 32075 Btuh Structure 30280 Btuh Ducts 11531 Btuh Ducts 16352 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 43607 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 46632 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 4700 Btuh Ducts 3180 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft2) 3946 3946 Equipment latent load 7880 Btuh Volume(ft') 42927 42927 Air changes/hour 0.25 0.13 Equipment total load 54512 Btuh Equiv.AVF (cfm) 179 93 Req. total capacity at 0.70 SHR 5.6 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O d Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4 +++ wrightsoft` Right-Suite®Universal 2015 15.0 19 RSU15431 2015-Sep-08 11 43e 1 ACC Developrnent\1588 Ocean Blvd\1588 Ocean Blvd rup Calc=MJ8 Front Door faces E 4 Building Analysis Job: 1588 Ocean Blvd Date: 09/07/2015 Entire House By: David C Brown ConsultAir, LLC Atlantic Beach.Fl 32233 Phone. (904)402-1463 Fax. (904)800-1222 Web.www.LoadCalculations.corn Pro'ect Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32773 Desi• n Conditions Location: Indoor: Heating Cooling Mayport Ns, FL, US Indoor temperature(°F) 70 75 Elevation: 13 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 27.2 55.4 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 78 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin. Component Btuh/ft2 Btuh %of load Walls 2.6 10010 23.0 Glazing 10.4 5654 13.0 "' Doors 12.2 482 1.1 Ceilings 1.0 2596 6.0 Floors 2.8 7159 16.4 Infiltration 1.5 6175 14.2 Ducts 11531 26.4 Piping 0 0 ....,. Humidification 0 0 - Ventilation 0 0 Adjustments 0 Total 43607 100.0 Coolin• Component Btuh/ft2 Btuh % of load Walls 1.9 7387 15.8 ..w, Glazing 19.9 10843 23.3 Doors 12.1 477 1.0 Ceilings 1.7 4514 9.7 Floors 0.0 81 0.2 Infiltration 0.4 1749 3.7 Ducts 16352 35.1 Ventilation 0 0 0.. Internal gains 5230 11.2 Blower 0 0 k<i" .L Adjustments 0 --- Total 46632 100.0 Latent Cooling Load= 7880 Btuh Overall U-value= 0.086 Btuh/ft2-°F Data entries checked. '414- wrightsoft 2015-Sep-08 1143 25 Right-Suite®Universal 2015 15.0.19 RSU15431 Page 1 'CCK Develooment11588 Ocean Blvd 11588 Ocean Blvd rup Calc=MJ8 Front Door faces E AED Assessment Job: 1588 Ocean Blvd Date: 09/07/2015 Entire House By: David C Brown ConsultAir, LLC Atlantic Beach,F]32233 Phone (904)402-1463 Fax (9041 800-1222 Web www.LoadCalculahons.corn Project Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32223 Design Conditions Location: Indoor: Heating Cooling Mayport Ns, FL, US Indoor temperature(°F) 70 75 Elevation: 13 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 27.2 55.4 Dry bulb(°F) 39 92 Infiltration: Daily range(OF) - 15 ( L ) Wet bulb(°F) - 78 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 1B, 14, 12,000 - I10,810 __ 8,n1 6,1,1 4,s,, 2,000 0 I . _ 8 9 10 11 12 13 14 15 16 17 18 19 20 Flour of Day Harry amaps Maximum hourly glazing load exceeds average by 51.9%. House does not have adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 2019 Btuh (PFG - 1.3*AFG) L Wri htso `" 2015 Sep 08 11 43 25 9 Right-Bute®Universal 2015 15.0.19 RSU15431 Page 1 ...Develepment11588 Ocean Blvd11588 Ocean Blvd rup Cale=MJ8 Front Door faces: E Load Short Form Job: 1588 Ocean Blvd Date: 09/07/2015 gt511943 Entire House By: David C Brown ConsultAir, LLC Atlantic Beach.Ft 32233 Phone.(904)402-1463 Fax.(904)800-1222 Web.www.LoadCalculations.corn Project Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32223 Design Information Htg Clg Infiltration Outside db(°F) 39 92 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 31 17 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 27 55 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft') (Btuh) (Btuh) (cfm) (cfm) 1st Floor System d 2473 27996 27843 1250 1250 2nd Floor System d 1473 15611 19087 850 850 Entire House d 3946 43607 46632 2100 2100 Other equip loads 0 0 Equip. @ 1.00 RSM 46632 Latent cooling 7880 TOTALS 3946 43607 54512 2100 2100 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. L. 2015-Sep-081143.25 �= wrightsosa-1 l Right-Suite®Universal 2015 15 0 19 RSU15431 Page 1 Developmenl11588 Ocean Blvd\1588 Ocean Blvd rup Calc=MJ8 Front Door faces. E Component Constructions Job: 158 Blvd Date: 09/07/2017/201 5 ASUAR Entire House By: David C Brown ''"'' ;:h•^,-,'.,; ConsultAir, LLC Atlantic Beach,FI 32233 Phone(904)402-1463 Fax:(904)800-1222 Web:www.LoadCalculations.corn Project Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32223 Design Conditions Location: Indoor: Heating Cooling Mayport Ns, FL, US Indoor temperature(°F) 70 75 Elevation: 13 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 27.2 55.4 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 78 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 i Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/IY-°F B'-°F/Btuh BRA/I!' Ruh BtuM' Stub Walls 12E-Osw:Frm wall,stucco ext,3/8"wood shth,r-19 cav ins, 1/2" n 590 0.068 19.0 2.14 1260 1.50 883 gypsum board int fish,2"x6"wood frm,16"o.c.stud e 355 0.068 19.0 2.14 757 1.50 530 s 462 0.068 19.0 2.14 986 1.50 691 w 518 0.068 19.0 2.14 1106 1.50 775 all 1925 0.068 19.0 2.14 4109 1.50 2879 Frm wall,Hardie ext,r-13 cav ins, 1/2"gypsum board int fnsh,2"x4" n 346 0.097 13.0 3.05 1055 2.54 877 wood frm,16"o.c.stud:Frm wall,Hardie ext,r-13 cav ins, 1/2" e 411 0.097 13.0 3.05 1256 2.54 1044 • gypsum board int fish,2"x4"wood frm, 16"o.c.stud s 352 0.097 13.0 3.05 1073 2.54 892 w 412 0.097 13.0 3.05 1257 2.54 1045 all 1520 0.097 13.0 3.05 4642 2.54 3858 Partitions 12C-Osw:Frm wall, 1/2"wood shth,r-13 cav ins,1/2"gypsum board 387 0.091 13.0 2.86 1105 1.47 570 int fnsh,2"x4"wood frm,16"o.c.stud 12C-Osw:Frm wall,stucco ext,r-13 cav ins,2"x4"wood frm,16"o.c. 54 0.091 13.0 2.86 154 1.47 80 stud Windows U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; n 16 0.330 0 10.4 166 8.37 134 50%outdoor insect screen;1.5 ft overhang(4 ft window ht,3 ft sep.); 6.67 ft head ht U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; n 12 0.330 0 10.4 124 8.37 100 50%outdoor insect screen; 1.5 ft overhang(6 ft window ht,2 ft sep.); n 36 0.330 0 10.4 373 8.37 301 6.67 ft head ht e 18 0.330 0 10.4 181 22.0 385 e 18 0.330 0 10.4 187 22.0 396 w 35 0.330 0 10.4 363 22.0 770 all 119 0.330 0 10.4 1228 16.5 1953 U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; n 10 0.330 0 10.4 104 8.37 84 50%outdoor insect screen; 1.5 ft overhang(5 ft window ht,1 ft sep.); s 10 0.330 0 10.4 104 8.37 84 6.67 ft head ht all 20 0.330 0 10.4 207 8.37 167 U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; n 36 0.330 0 10.4 373 8.37 301 50%outdoor insect screen;1.5 ft overhang(6 ft window ht,0.5 ft sep.); e 54 0.330 0 10.4 560 20.3 1097 6.67 ft head ht all 90 0.330 0 10.4 933 15.5 1398 1 wr htsofC 2015-Sep-08 11:43:25 �• Right-Suite®Universal 2015 15.0.19 RSU15431 ..Development11588 Ocean Btvd11588 Ocean Blvd.rup Cak=MJ8 Front Door faces: E Pape 1 U-value.33 SHGC.23:U-value.33 SHGC.23;5 ft overhang(5 ft e 30 0.330 0 10.4 311 20.3 608 window ht,2 ft sep.);6.67 ft head ht U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; e 8 0.330 0 10.4 83 21.2 169 50%outdoor insect screen;1.5 ft overhang(4 ft window ht,1 ft sep.); e 8 0.330 0 10.4 86 21.2 176 6.67 ft head ht all 16 0.330 0 10.4 169 21.2 346 U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; s 30 0.330 0 10.4 311 8.37 251 50%outdoor insect screen;1.5 ft overhang(5 ft window ht,2 ft sep.); 6.67 ft head ht U-value.33 SHGC.23:U-value.33 SHGC.23;8 ft overhang(8 ft w 24 0.330 0 10.4 249 17.7 424 window ht,2 ft sep.);6.67 ft head ht w 96 0.330 0 10.4 995 17.7 1697 all 120 0.330 0 10.4 1243 17.7 2121 U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; w 35 0.330 0 10.4 363 11.5 401 50%outdoor insect screen;8 ft overhang(6 ft window ht,2 ft sep.); 6.67 ft head ht U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; w 24 0.330 0 10.4 249 22.0 528 50%outdoor insect screen;1.5 ft overhang(3 ft window ht,2 ft sep.); 6.67 ft head ht U-value.33 SHGC.23:U-value.33 SHGC.23;40%blinds 45°,light; w 15 0.330 0 10.4 155 20.0 300 50%outdoor insect screen;1.5 ft overhang(5 ft window ht,0.5 ft sep.); w 31 0.330 0 10.4 319 20.0 616 6.67 ft head ht all 46 0.330 0 10.4 475 20.0 916 Doors 11DO:Door,wd sc type e 18 0.390 0 12.2 220 12.1 218 n 21 0.390 0 12.2 261 12.1 259 all 39 0.390 0 12.2 482 12.1 477 Ceilings 16B-30md:Attic ceiling,mtl roof mat,r-30 ceil ins,1/2"gypsum board 2584 0.032 30.0 1.00 2596 1.75 4514 int fish Floors 20P-19t:Fir floor,frm flr,17'thkns,tile fir fish,r-19 cav ins,amb ovr 111 0.050 19.0 1.57 174 0.73 81 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth,tile flr 189 1.180 0 37.1 6984 0 0 fnsh Al..- wr htsoft- 2015-Sep-0811.43:25 �, Right-Suite®universal 2015 15.0.19 Rsu15431 Page 2 ..Development\1588 Ocean Btvd\1588 Ocean Blvd.rup Calc=MJ8 Front Door faces: E Load Multizone Summary Report Job: 1588 Ocean Blvd Date: 09/07/2015 "■l-r' By: David C Brown ConsultAir, LLC Atlantic Beach,FI 32233 Phone:(904)402-1463 Fax:(904)800-1222 Web:www.LoadCalculations.com i Infiltration Summary Heating Cooling ZONENAME Volume ACH AVF HTM Volume ACH AVF HTM W cfm Btuh/ft2 ft cfm Btuh/ft2 1st Floor System 29670 0.20 101 1 .5 29670 0. 11 52 0.4 2nd Floor System 13257 0. 35 78 1 .5 13257 0. 18 41 0.4 Entire House 42927 0.25 179 1 . 5 42927 0. 13 93 0. 4 Load and AVF Summary ROOM NAME Arca Htg load Clg load HtgAVF CIgAVF IV Btuh Btuh cfm cfm Mstr WIC 126 2857 1200 128 54 Linen 9 0 0 0 0 Mstr Bth 155 2245 1052 100 47 Mstr Bdrm 324 2742 4626 122 208 Mstr H2O 26 0 0 0 0 I. Mud Rm 49 571 517 25 23 I Clst 21 667 314 30 14 Foyer 259 2522 1863 113 84 Office 196 4569 3529 204 158 Bth 1 56 88 117 4 5 Office Clst 23 0 0 0 0 Pantry 45 742 358 33 16 Family Rm 248 3252 5076 145 228 Dining Rm 264 5045 5148 225 231 Kit Clst 6 0 0 0 0 Family Kitchen 666 2696 4043 120 182 1st Floor System 2473 27996 27843 1250 1250 Bdrm 3 189 2493 2671 136 119 Clst 3 30 0 0 0 0 Bdrm 2 189 1447 2559 79 114 Clst 2 20 0 0 0 0 H2O 2 19 400 506 22 23 Bth 2 93 588 739 32 33 Laundry 77 107 873 6 39 Bdrm 1 216 2793 2924 152 130 WIC 1 40 877 836 48 37 Chase 2 0 0 0 0 1 Bth 3 51 982 931 53 41 Loft 534 5924 7049 323 314 13 0 0 0 0 2nd Floor System 1473 15611 19087 850 850 Entire House 3946 43607 46632 2100 2100 .� wri htsoft 2015-Sep-081143:25 9 Right-Suite®Universal 2015 15.0.19 RSU15431 Page 1 ACCA Development 11588 Ocean BIvd11588 Ocean Blvd.rup Calc=MJ8 Front Door faces: E r 6'5U1,413 Duct System Summary 1st Floor System ConsultAir, LLC Job: 1588 Ocean Blvd Y 7 Date: 09/07/2015 By: David C Brown Atlantic Beach,FI 32233 Phone.(904)402-1463 Fax (904)800-1222 Web www.LoadCalculations corn Project Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32223 Heating Cooling External static pressure 0.55 in H2O 0.55 in H2O Pressure losses 0.09 in H2O 0.09 in H2O Available static pressure 0.46 in H2O 0.46 in H2O Supply/return available pressure 0.213/0.247 in H2O 0.213/0.247 in H2O Lowest friction rate 0.097 in/100ft 0.097 in/100ft Actual air flow 1250 cfm 1250 cfm Total effective length (TEL) 477 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bth 1 c 117 4 5 0.133 4.0 Ox 0 VIFx 55.9 105.0 st2 clst h 667 30 14 0.140 4.0 Ox 0 VIFx 26.9 125.0 st3 Dining Rm c 2574 113 116 0.103 8.0 Ox 0 VIFx 78.0 130.0 st4 Dining Rm-A c 2574 113 116 0.101 8.0 Ox 0 VIFx 80.7 130.0 st4 Family Kitchen-A c 2022 60 91 0.097 7.0 Ox 0 VIFx 89.0 130.0 st4 Family Kitchen-B c 2022 60 91 0.097 7.0 Ox 0 VIFx 91.0 130.0 st4 Family Rm c 2538 73 114 0.113 8.0 Ox 0 VIFx 68.3 120.0 st4 Family Rm-A c 2538 73 114 0.105 8.0 Ox 0 VIFx 72.9 130.0 st4 Foyer h 2522 113 84 0.129 7.0 Ox 0 VIFx 34.9 130.0 st3 Mstr Bdrm c 2313 61 104 0.144 7.0 Ox 0 VIFx 32.9 115.0 st1 Msir Bdrm-A c 2313 61 104 0.135 7.0 Ox 0 VIFx 43.2 115.0 st1 Mstr Blh h 2245 100 47 0.179 6.0 Ox 0 VIFx 9.5 110.0 Mslr H2O c 0 0 0 0.215 0 Ox 0 VIFx 19.0 80.0 MstrWlc h 2857 128 54 0.150 7.0 Ox0 VIFx 27.0 115.0 st1 Mud Rm h 571 25 23 0.244 4.0 Ox 0 VIFx 12.5 75.0 Office h 2284 102 79 0.108 7.0 Ox 0 VIFx 57.8 140.0 st3 Office-A h 2284 102 79 0.127 7.0 Ox 0 VIFx 58.5 110.0 st2 Pantry h 742 33 16 0.127 5.0 Ox 0 VIFx 57.5 110.0 st2 � wrightsoft 2015-Sep-08 11 age 1 . 9 Right-Suited Universal 2015 15 0 19 RSU15431 Page 1 /CC .Development\1588 Ocean Blvd\1588 Ocean Blvd rup Calc=MJ8 Front Door faces E Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 139 101 0.127 398 8.0 0 x 0 VinIFIx st3 Peak AVF 244 177 0.108 448 10.0 0 x 0 VinIFIx st4 Peak AVF 491 641 0.097 599 14.0 0 x 0 VinIFIx st1 Peak AVF 250 262 0.135 480 10.0 0 x 0 VinIFIx Return Branch Detail Table Grill Htg Clg TEL Design ' Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rsbl Ox0 204 158 180.6 0.137 584 8.0 Ox 0 VIFx rt1 rb4 Ox0 696 783 255.6 0.097 561 16.0 Ox 0 VIFx rt3 rb3 Ox0 350 309 234.2 0.105 446 12.0 Ox 0 VIFx rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 1250 1250 0.097 707 18.0 0 x 0 ViniFlx rt3 Peak AVF 1046 1092 0.097 618 18.0 0 x 0 VinIFIx rt1 4 i+ wri htsoft' 2015-Sep-08 11 43 52 + g Right-Suited Universal 2015 15 0 19 RSU15431 pie 2 1CCN Developmentt1588 Ocean BIvd11588 Ocean Blvd rup Calc=MJB Front Door faces E Duct System Summary Job: 1587/2015 Blvd Y Summary Date: 09/0712015 ertsuljr 2nd Floor System By: David C Brown ConsultAir, LLC Atlantic Beach.Fl 32233 Phone:(904)402-1463 Fax:(904)800-1222 Web:www.LoadCalculations.com Project Information For: OSSI Homes and Development 1588 Ocean Blvd,Atlantic Beach, FL 32223 Heating Cooling External static pressure 0.55 in H2O 0.55 in H2O Pressure losses 0.09 in H2O 0.09 in H2O Available static pressure 0.46 in H2O 0.46 in H2O Supply /return available pressure 0.237/0.223 in H2O 0.237/0.223 in H2O Lowest friction rate 0.135 in/100ft 0.135 in/100ft Actual air flow 850 cfm 850 cfm Total effective length(TEL) 341 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk Bdrm 1 h 2793 152 130 0.144 8.0 Ox 0 VIFx 34.7 130.0 st5 Bdrm 2 c 2559 79 114 0.288 6.0 Ox 0 VIFx 7.3 75.0 Bdrm 3 h 2493 136 119 0.287 7.0 Ox 0 VIFx 7.6 75.0 Bth 2 c 739 32 33 0.156 5.0 Ox 0 VIFx 22.5 130.0 st5 Bth 3 h 982 53 41 0.288 5.0 Ox 0 VIFx 7.5 75.0 H2O 2 c 506 22 23 0.164 4.0 Ox 0 VIFx 24.6 120.0 st5 Laundry c 873 6 39 0.153 5.0 Ox0 VIFx 25.3 130.0 st5 Loft h 1975 108 105 0.135 7.0 Ox0 VIFx 30.8 145.0 st6 Loft-A h 1975 108 105 0.142 7.0 Ox 0 VIFx 26.9 140.0 st6 Loft-B h 1975 108 105 0.141 7.0 Ox0 VIFx 28.9 140.0 st6 WIC 1 h 877 48 37 0.143 5.0 Ox 0 VIFx 36.0 130.0 st5 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 323 314 0.135 591 10.0 0 x 0 VinIFIx st5 Peak AVF 259 262 0.143 592 9.0 0 x 0 VinIFIx I .` -}if wrightsoft 2o1s Sep os 11 ag s3 f' 7 Right-Suite®Universal 2015 15 Q19 RSU 15431 Faye 3 ACCA Development\1588 Ocean Blvd\1588 Ocean Blvd rup Calc=MJ8 Front Door faces: E Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 133 169 148.9 0.149 485 8.0 Ox 0 VIFx rt2 rb10 Ox 0 200 167 164.8 0.135 452 9.0 Ox 0 VIFx rt2 rb8 Ox 0 328 353 136.9 0.163 647 10.0 Ox 0 VIFx rt2 rb9 Ox 0 189 160 135.2 0.165 542 8.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt2 Peak AVF 850 850 0.135 609 16.0 0 x 0 ViniFlx 4 4 4 2015-Sep-08 11 43 52 . wrightsot Right-Suite®Universal 2015 15.0.19 RSU15431 Page 4 ACC Development11588 Ocean Blvd\1588 Ocean Blvd.rup Calc=MJ8 Front Door faces. E