Loading...
201 S NAUTICAL BLVD - IRRIGATION , CITY OF ATLANTIC BEACH • f 800 SEMINOLE ROAD T\-) /;r ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 PLUMBING PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-IRR-2410 Job Type: IRRIGATION/SPRINKLER Description: IRRIGATION Estimated Value: Issue Date: 10/21/2015 Expiration Date: 4/18/2016 PROPERTY ADDRESS: Address: 201 S NAUTICAL BLVD RE Number: 170703-0386 PROPERTY OWNER: Name: WARDREP, CHRISLEY P Address: 201 NAUTICAL BLVD GENERAL CONTRACTOR INFORMATION: Name: AMERICAN WELL & IRRIGATION,INC. Address: 1651 MAYPORT RD Phone: 904-249-5400 FEES: State PLMG DBPR Surcharge $2.00 State PLMG DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Plumbing Fixtures $7.00 Total Payments: $66.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. , LM)," City of Atlantic Beach APPLICATION NUMBER �s Building Department (To be assigned by the Building Department.) �� 800 Seminole Road 1 5 _ 1 ;� _ z/' ' C �` Atlantic Beach, Florida 32233-5445 I` 4{ Phone(904)247-5826 Fax(904)247-5845 /... Email: building dept @coab.us Date routed: I O I Z {S City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM S Property Address: Z 01 N A()TI et(A c Lv 3 Department review required Yes No 1 ,, ' Buildin Applicant: RMeRic b �/V -L I �� tanning &Zonin t� Tree a_or - Project: I 2 R... f7, 0 Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection T Florida Dept. of Transportation — St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ,Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING / Reviewed by: �0+��!/ 2 Date: klAiyI,s TREE ADMIN. --- -- --. — -------Second Review: Approved as revised. ['Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 PLUMBING PERMIT APPLICATION CITY OF ATLANTIC BEACH z4 U 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904)247-5826 Fax (904) 247-5845 1 5-- } i f,3i ,A I 0 JOB ADDRESS: th\ 1 a Llb CM i 3\v d. S. PERMIT# NEW OR REPLACEMENT INSTALLATION: Project Value$ TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank& Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink - Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System RE-PIPE: TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank& Pit • Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: 0 Sewer Replacement Back Flow Preventer 0 Grease Interceptor(Trap) gallons(Requires 3 sets of plans) Lawn Sprinkler System-Number of Heads 20 o Well ** SJRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.** o Other Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give a thority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name e-‘ni r:S W (Xr&'1 Phone Number 241,0.1 9,) p Plumbing Company �n es r Ca(\ U�e\ l 4 \''(' f . Office Phone ax(il-ttnn A 11 Co. Address: \tpt 1 Mai 1:1O1'1 City State 1Zipi ,323 License Holder(Print): 04/Se_L_` State Certification/Registration# Hp X N.. • • ..f , it re o License Holder _ra/ - io n. Notary public State of Florida Before me this s• "vi �e 20 /6.) Shirley LGraham h � ,� _ MY Commission FF 086990 �►�@a Expires 02/14/2018 Signature of Notary Pu• • Florida Friendly Landscapes i1 J� - '.;a r IRRIGATION COMPLIANCE CHECKLIS T 'I _11HJFr" DATE 1b 111-. 1. A. PROVIDE PROJECT INFORMATION: t `-� ADDRESS 'La l N au-h• Co\ \ I V 0 . ` , r- RESIDENTIAL, NEW INSTALLATION V j C t,(�\1(- (.....0 0 C e V RESIDENTIAL, CONTRACTOR 1 Y n ,� ! UPGRADE/REPLACE OFFICE /I.6 .59N) CELL 2_ ' � FAX 2 9 c4 i 1 �� NEW INSTALNATION r� r 1� NON-RESIDENTIAL, EMAIL Ut�-C f ' l'1A,C,� l \ I r7 qrsnol . c iney UPGRADE/REPLACE R. CALCULATE MAXIMUM HIGH VOLUME IRRIGATION: I HYDROZONE steall mean an irrigation watering zone TOTAL LOT AREA H C O SQ FT in which plant materials with similar water needs are I grouped together. CI'TOTAL IMPERVIOUS SURFACE AREA - L-1 SQ FT HIGH VOLUME IRRIGATION shall mean an irrigation system that does not limit the delivery of water directly to the root zone and which has a minimum TOTAL PERVIOUS AREA/LANDSCAPE 1) 0 SQ FT flow rate,per emitter, of thirty(30) gallons per hour (gph) or one-half (5) gallons per minute (gpm) or greater. (PER SECTION 24-18 i(b)(4)ii) x 0.60 IRRIGATION ZONE shall mean the grouping together MAX HIGH VOLUME IRRIGATION 49) 3 i q-D, SQ FT of any type of water emitter and irrigation equipment operated simultaneously by the control of a timer and a single valve. C. PREPARE&ATTACH A HYDROZONE PLAN: ON A COPY OF THE SITE PLAN OR SURVEY(RESIDENTIAL APPLICANTS)OR A LANDSCAPE PLAN(NON-RESIDENTIAL APPLICANTS),INDICATE THE LOCATION OF THE FOLLOWING AND FILL IN APPROXIMATE COVERAGES BELOW. i . HIGH WATER USE HYDROZONE(S) [ALL APPLICANTS] �� �� 1 t)� "`CCC SO FT %TLA igh Water Use Hydrozones contain plants that require supplemental watering on a regular basis throughout the year. These areas include turf and lawn grasses and are typically characterized by high visibility focal points of landscaping design where High Volume Irrigation is used. High Water Use Zones shall be placed on a separate irrigation zone. -- MODERATE WATER USE HYDROZONE(S) [NON-RESIDENTIAL ONLY] SQ FT %TLA Moderate Water Use Hydrozones contain plants that once established,require irrigation every two to three weeks in absence of rainfall or when they show visible stress such as wilted foliage or pale color. These are typically perennials,seasonal plants and flower beds. LOW WATER USE HYDROZONE(S) [NON-RESIDENTIAL ONLY] SQ FT %TLA Low Water Use Hydrozones contain plants that rarely require supplemental watering and that are drought tolerant during extreme dry periods,such as native shrubs and vegetation,established trees and ground covers,and wooded areas. �'stOISTURE SENSOR(S) [ALL APPLICANTS] At least one(1)moisture sensor shall be located in each Irrigation Zone. EMITTERS [ALL APPLICANTS] Emitters shall be sized and spaced to avoid excessive overspray on to impervious surfaces. City of Atlantic Beach • 800 Seminole Road • Atlantic Beach,Florida 32233 (P)904.2475800 • (F)904.247.5845 - www.coab.us FFL-ICC v12.07.10