Loading...
1649 ATLANTIC BEACH DR - REVISION HVAC / ,t CITY OF ATLANTIC BEACH ,, \ss,1 800 Seminole Road 0 Atlantic Beach,Florida 32233 L.) �r Telephone(904)247-5800 FAX(904)247-5845 REVISION REQUEST SHEET Date: 1b/ 0 11 5 Received by: ,'C Resubmitted: p z Q / Permit Number: 15_ SP/Q--1�� I Original Plans Examiner: r7.kt ,Sovc 5 Project Name: Project Address: /b� 4L.-h'c rsu,c_l, ✓,y Contractor:7+1i ✓sip f/3 —Ave tiering Contact Name: J ate, C4,.t<.4 — Contact Phone : 9o'(—'/ ?-`t6G3 Contact e-mail: j c_o,-.t c/ /i(r,Nrs;,14,Co„`, Revision/Plan Check/Permit Fee(s) Due: $ Description of Proposed Revision to Existing Permit: 4V d-1 a, of- se cit AL u-4;}— ______________ Additional Increase in Building Value: $ Additional S.F. Site Plan Revised: Public W/U Approval: By signing below.I(print name) JK S e o..ti(-41-- affirm that the above revision is inclusive of the proposed changes. i V /.? 0 b C Sign ture of Contractor Agent(Contractor must sign if increase in valuation) Date �/ Office Use Only Date: /O ~ 6 ./ Approved: /\ Rejected: Notified by: Plan Review Comments: / /9�reued Q S kevi y 'c - Scan Offs Q ow -4a £1 f it I 1 e -'r An eel py lo s)1'k.. 47 Department review required Yes No Building___ rn &Zoning Tree Administrator Tans Examiner Public Works Public Utilities /D.d. 6r /5.-- Public Safety Fire Services Date Created 8/20/15 Rev.2 OFFICE COPY FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Terrano 3058 Left Builder Name: Toll Brothers Street: 1649 Atlantic Beach Dr Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, - Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,St.Augustine 1. New construction or existing New(From Plans) 9. Wall Types(4258.9 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 3708.90 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 550.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (1763.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1763.00 ft2 2 6. Conditioned floor area above grade(ft2) 3058 b.N/A R=ft2 c.N/A Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(443.9 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 212 a. U-Factor: Dbl,U=0.34 443.92 ft2 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 282 SHGC: SHGC=0.27 ft2 12.Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a.Central Unit 24.0 SEER:14.00 SHGC: b.Central Unit 24.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:8.20 SHGC: b.Electric Heat Pump 24.0 HSPF:8.20 Area Weighted Average Overhang Depth: 4.179 ft. 14.Hot water systems Area Weighted Average SHGC: 0.270 Cap:Ca 1 gallons a.Natural Gas Tankless 8. Floor Types (3058.0 sqft.) Insulation Area EF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 1597.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1295.00 ft2 None c.other(see details) R= 166.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 36.56 7:..07.1.4i.,.... Glass/Floor Area: 0.145 Total Standard Reference Loads: 65.18 I hereby certify that the plans and specifications covered by Review of the plans and 0 . ., +4 this calculation are in compliance with the Florida Energy specifications covered by this at ti ..•. �''= `; `(.,� �z calculation indicates compliance i c0._.>n, f� _-_,, . C Code. g F. nurr:.w, '4°,4 a: with the Florida Energy Code. •(��'=`�•�` °I ■ 6 - � a ���.� � 6l Before construction is completed �'---pi.- ''��° �,I• • PREPARED B : _ Y, DATE: v� this building will be inspected for a >:p;�«� compliance with Section 553.908 *`�., tot 4' ,•'�} Florida Statutes. ,ems' µ .• g'S� I hereby certify that this building, as designed, is in compliance �4.<«Cpi7 w, ,�,° with the Florida Energy Code. «....,,....r�• DATE: OWNER/AGENT: � J[/l _ _ BUILDING OFFICIAL: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 'OFFICE COPY REVISION BP# /5-S1---R-/2 C DATE �p /, / 10/20/2015 4:04 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 C o r e r/Care Ct Page 1 of 6 PROJECT Title: Bedrooms: 3 Address Type: Street Address Building Type: User Terrano 3058 Left Conditioned Area: 3058 Lot# 5 2 Block/SubDivision: Total Stories: Owner: Toll Brothers Plat Book: of Units: 1 Worst Case: No Builder Name: Toll Brothers Rotate Angle: 0 Street: 1649 Atlantic Beach Dr Cross Ventilation: No County: Duval 261 Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach, Jurisdiction: 261300 Whole House Fan: No y' FL, Family Type: Single-family New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,St.Augustine FL_JACKSONVILLE_INT 2 32 93 70 75 1281 64 Medium BLOCKS _ Number Name Area Volume 1 Block1 1597 15970 2 Block2 1461 13149 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Inf l ID Finished Cooled Heated 1 Main 1597 15970 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 1461 13149 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor over Garage 2nd Floor _� 166 ft2 0 0 0 1 2 Slab-On-Grade Edge insulatio Main 208.3 ft 0 1597 ft2 __ 0 0 1 3 Floor Over Other Space 2nd Floor ___ ___ 1295 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1910 ft2 366 ft2 Medium 0.8 N 0.9 No 0 22.6 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1763 ft2 N N i 10/20/2015 4:04 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING V # Ceilin 9 Type T Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 38 1461 ft2 0.11 Wood 2 Under Attic(Vented) Main 38 302 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below V/ Space R-\Iahie Ft In Ft In Area R-value Fraction Absor Grade.% # Qrnt Tn Wall Type 1 N Exterior Frame-Wood 2nd Floor 19 51 4 9 0 462.0 ft2 0 0.25 0.8 0 2 N Exterior Frame-Wood Main 19 63 0 10 0 630.0 ft2 0 0.25 0.8 0 3 E Exterior Frame-Wood 2nd Floor 19 41 1 9 0 369.8 ft2 0 0.25 0.8 0 _4 E Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.25 0.8 0 _ 5 S Exterior Frame-Wood 2nd Floor 19 52 6 9 0 472.5 ft2 0 0.25 0.8 0 6 S Exterior Frame-Wood Main 19 61 11 10 0 619.2 ft2 0 0.25 0.8 0 7 W Exterior Frame-Wood 2nd Floor 19 39 6 9 0 355.5 ft2 0 0.25 0.8 0 _ 8 W Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.25 0.8 0 9 W Garage Frame-Wood Main 13 55 0 10 0 550.0 ft2 0 0.25 0.8 0 DOORS Storms U-Value Width Height Area # Ornt Door Type Space Ft In Ft In 1 W Insulated Main None .6 3 8 24 ft2 2 W Wood Main None .39 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.34 0.27 31.0 ft2 1 ft 0 in 1 ft 6 In None Exterior 5 2 N 1 Vinyl Low-E Double Yes 0.34 0.27 8.3 ft2 1 ft 0 in 1 ft 6 In None Exterior 5 3 N 2 Vinyl Low-E Double Yes 0.34 0.27 3.6 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 4 E 3 Vinyl Low-E Double Yes 0.34 0.27 33.3 ft2 4 ft 8 in 1 ft 6 In n 1 ft 6 in None Exterior 5 I 5 E 4 Vinyl Low-E Double Yes 0.34 0.27 62.0 ft2 8 ft 4 I None Exterior 5 6 E 4 Vinyl Low-E Double Yes 0.34 0.27 96.0 ft2 8 ft 4 in 1 ft 6 in None Exterior 5 I 7 S 5 Vinyl Low-E Double Yes 0.34 0.27 21.5 ft2 1 ft 0 in 1 ft 6 In None Exterior 5 8 S 5 Vinyl Low-E Double Yes 0.34 0.27 21.3 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 9 S 6 Vinyl Low-E Double Yes 0.34 0.27 21.5 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 10 W 7 Vinyl Low-E Double Yes 0.34 0.27 39.6 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 11 W 7 Vinyl Low-E Double Yes 0.34 0.27 6.6 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 12 W 7 Vinyl Low-E Double Yes 0.34 0.27 6.5 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 13 W 8 Vinyl Low-E Double 14 W 8 Vinyl Low-E Double Yes 0.34 0.27 31.0 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 Yes 0.34 0.27 16.0 ft2 8 ft 9 in 1 ft 6 in None Exterior 5 Exterior 5 15 E 3 Vinyl Low-E Double Yes 0.34 0.27 15.5 ft2 1 ft 4 in 1 ft 6 in None 16 S 6 Vinyl Low-E Double Yes 0.34 0.27 15.5 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 17 E 3 Vinyl Low-E Double Yes 0.34 0.27 4.0 ft2 1 ft 4 in 1 ft 6 in None Exterior 5 18 N 2 Vinyl Low-E Double Yes 0.34 0.27 10.7 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 I i 10/20/2015 4:04 PM EnergyGauge®Ener Gau e®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 I ' GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 586 ft2 420 ft2 64ft 10ft 1 INFILTRATION ► # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 . 1 Wholehouse Best Guess .0003 2406.4 132.11 248.44 .2844 4.9583 • HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 24 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:8.2 24 kBtu/hr 2 sys#2 COOLING SYSTEM J # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:14 24 kBtu/hr 720 cfm 0.700000 1 sys#1 2 Central Unit None SEER:14 24 kBtu/hr 720 cfm 0.7 2 sys#2 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.59 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM JFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS V # --Supply— —Return— Air CFM 25 CFM25 HVAC# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 212 ft2 Attic 113 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1 2 Attic 6 282 ft2 Attic 119 ft2 Default Leakage 2nd Floor (Default) (Default) 2 2 ► { 10/20/2015 4:04 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Prcgramable Thermostat:Y Ceiling Fans: I Jun ri Jul Aug X Sep 1 Oct ]]Nov [ Dec Coaling [xi Jan [[ ]]Feb ' ]]Mar ]Apr [[ ]May e 1 Oct X Nov [X Dec Heating Jan ]Feb X]Mar Apr [ ]Mal Jun Jul [ Aug I 1 Sep X Oct X1]Nov [ Dec Venting Jan [[ ]]Feb XJJ Mar X]A r [[ ]Ma Jun Jul 111 111 Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 66 66 1 • 1 1 [ 10/20/2015 4:04 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 • FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 1649 Atlantic Beach Dr PERMIT#: Atlantic Beach, FL, - MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) I CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors=0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces: gasketed doors &outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. • 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in i Table 403.4.3.2. Provide switch or clearly marked circuit breaker s . (electric) or shutoff(gas). Circulating system pipes insulated to= R-2 • +accessible manual OFF switch. _ Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent �% to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas �� and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. 1 Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or v variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 1 10/20/2015 4:04 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 • ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 56 The lower the EnergyPerformance Index, the more efficient the home. 1649 Atlantic Beach Dr, Atlantic Beach, FL, - 9. Wall T es Insulation Area 1. New construction or existing New(From Plans) a.Frame-Wood,Exterior R=19.0 3708.90 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 550.00 ft2 R= ft2 3. Number of units,if multiple family 1 c.N/A d.N/A R= ft2 4. Number of Bedrooms 3 Insulation Area 10.Ceiling Types 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1763.00 ft2 6. Conditioned floor area(ft2) 3058 b.N/A F2= ft2 c.N/A R= ft2 7. Windows" Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.34 443.92 ft2 a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 212 SHGC: SHGC=0.27 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 282 b. U-Factor: N/A ft2 kBtu/hr Efficiency SHGC: 12.Cooling systems ft2 a.Central Unit 24.0 SEER:14.00 S HGC: c. Factor: N/A b.Central Unit 24.0 SEER:14.00 SHGC: ft2 kBtu/hr Efficiency d. U-Factor: N/A 13.Heating systems SHGC: a.Electric Heat Pump 24.0 HSPF:8.20 Area Weighted Average Overhang Depth: 4.179 ft. b.Electric Heat Pump 24.0 HSPF:8.20 Area Weighted Average SHGC: 0.270 Insulation Area 14.Hot water systems Cap: 1 gallons 8. Floor Types a.Slab-On-Grade Edge Insulation R=0.0 1597.00 ft2 a.Natural Gas EF:0.59 b.Floor Over Other Space R=0.0 1295.00 ft2 b. Conservation features c.other(see details) R= 166.00 ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ��,�OZHL Srg4.'. .,*.. Construction through the above energy saving features which will be installed (or exceeded) ,r ...;•-•:'� = = o�:: in this home before final inspection. Otherwise, a new EPL Display Card will be completed �,,�,,,f jI ,,. e compliant fea res. `u,,,, " .-,l ,;.0, ,t; :. based on installed Code comp 1 -r'°:1''" .. i 1 1 c4 Builder Signature: ,----- Date: I O��0 I / S 0 ;14--t Address of New Home: L / 4„L, 6i City/FL Zip: 0.1}-jc_66,(11 1‘. c -,4:;s•'� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Terrano 3058 Left Builder Name: Toll Brothers Street: 1649 Atlantic Beach Dr Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach, FL, - Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,St.Augustine COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors • Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. •x„y Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software McGowan Project Summary Jo e. Lot AB HestingKAir 1st Floor By: Stephen Barber Conditioning r�.� w,� •. I i McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Pro"ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Notes: The Terrano Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 96 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 21 °F Daily range M Relative humidity 50 % Moisture difference 48 gr./lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16748 Btuh Structure 11468 Btuh Ducts 1770 Btuh Ducts 2230 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18518 Btuh Use manufacturer's data n Rate/swing multiplier 1.01 Infiltration Equipment sensible load 17711 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1338 Btuh Ducts 332 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1597 1597 Equipment latent load 1670 Btuh Volume(ft3) 16133 16133 Air changes/hour 0.24 0.13 Equipment total load 19381 Btuh Equiv.AVF(cfm) 65 35 Req.total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB0240000A Cond CH14NB0240000A AHRI ref 0 Coil FB4CNP025 AHRI ref 0 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 15540 Btuh Heating output 22200 Btuh @ 47°F Latent cooling 6660 Btuh Temperature rise 27 °F Total cooling 22200 Btuh Actual air flow 740 cfm Actual air flow 740 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri P.+. ft' 2015-Oct-20 16:12:57 At. g Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 /� ...onstruction\Toll Brothers\Terrano 3058 Left.rup Calc=MJ8 Front Door faces: W McGowan' Project Summary Job: Lot 9AB Heatinc�B,4ir Re Main By: Stephen Barber Conditioning`�� r '= '''-'. ('° McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Koreycmcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Notes: The Terrano Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 96 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 21 °F Daily range M Relative humidity 50 % Moisture difference 48 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 10932 Btuh Structure 9637 Btuh Ducts 1690 Btuh Ducts 2125 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12623 Btuh Use manufacturer's data n Rate/swing multiplier 1.01 Infiltration Equipment sensible load 17590 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2105 Btuh Ducts 317 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1461 1461 Equipment latent load 2422 Btuh Volume(ft3) 13820 13820 Air changes/hour 0.32 0.17 Equipment total load 20012 Btuh Equiv.AVF(cfm) 75 40 Req.total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB0240000A Cond CH14NB0240000A AHRI ref 0 Coil FB4CNP025 AHRI ref 0 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 15540 Btuh Heating output 22200 Btuh @ 47°F Latent cooling 6660 Btuh Temperature rise 27 °F Total cooling 22200 Btuh Actual air flow 740 cfm Actual air flow 740 cfm Air flow factor 0.059 cfm/Btuh Air flow factor 0.063 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ak. ilk wri htSOtft� 2015-Oct-20 16:12:e7 g Comfort Builder by VJrightsoft 15.0.17 RSU12270 Page 2 ...onstruction\Toll Brothers\Terrano 3058 Left.rup Calc=MJ8 Front Door faces: W First Floor 1 Breakfas 12 x 6 Family ROOT ti•• 7 U 10 U 14x6 14x6 11 •� 8" 8 Kitcher 8 x 4 .■, 10x6 Bath Stall 6" 12" 6x10 8x4 �. 4, • 6„ Pantrl -B�i,er Pant;( 12x20 • • 12" 12" 10" Study ;•I :•. 10x6 6x14 12 x 12 14" 6„ 8„ 8" Dining Rs r • • oye • GetfBgC 14" 12x20 12" Job #: Lot 9 AB McGowan's Heating & Air Conditioning,. Scale: 1 : 89 Performed by Stephen Barber for: Page 1 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.17 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Oct-20 16:13:10 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com Korey @mcgowansac.com ...I Brothers\Terrano 3058 Left.rup www.tollbrothers.com smerten@tollbrathersinc.com x.� Second Floor II Walk-In 1 Master Bedroo 8x4 12x6 Bedroom 7,. 4„ • 114x14 10x6 10x6 12" 6" 6I,2x,2 e Laun• 10x6 ti T•WJ 8 x 4 1g„ 8x4 8x4 4„ 4" Bath 3 4„ • 18 x 18 I\ 14" Hall 4 Ma P Batl Stair:: 12 x 12 9" 12x6 .* • Bedroom 7" ! .,,. Loft 12x6 7" Job #: Lot 9 AB McGowan's Heating & Air Conditioning,. Scale: 1 : 89 Performed by Stephen Barber for: Page 2 Steve Menen 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.17 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Oct-20 16:13:11 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com Kore y m owansac.com I Brothers\Terrano 3058 Left.rup www.tollbrothers.com smerten @tollbrothersinc.com McGowan Job: Lot 9 AB Duct System Summary Date: a ;2 , 1st Floor By: Stephen Barber ue i3avaN" McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com i Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.250/0.140 in H2O 0.250/0.140 in H2O Lowest friction rate 0.090 in/100ft 0.090 in/100ft Actual air flow 740 cfm 740 cfm Total effective length(TEL) 432 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath h 948 38 19 0.118 4.0 Ox 0 VIFx 42.5 170.0 st3 Breakfast h 2883 115 98 0.090 7.0 Ox 0 VIFx 66.5 210.0 st4 Dining Room c 3793 187 205 0.096 8.0 Ox 0 VIFx 49.0 210.0 st6 Family Room c 2970 127 160 0.096 8.0 Ox 0 VIFx 54.5 205.0 st4 Family Room-A c 2970 127 160 0.120 8.0 Ox 0 VIFx 38.5 170.0 st3 Hall 1 c 795 33 43 0.117 6.0 Ox 0 VIFx 38.5 175.0 st5 Kitchen h 1628 65 24 0.093 6.0 Ox 0 VIFx 53.0 215.0 st6 Pantry h 145 6 3 0.093 4.0 Ox 0 VIFx 52.6 215.0 st6 Study h 1050 42 28 0.117 6.0 Ox 0 VIFx 34.0 180.0 st5 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 242 258 0.090 473 10.0 0 x 0 VinIFIx st3 st3 Peak AVF 407 438 0.090 557 12.0 0 x 0 VinIFIx st1 st5 Peak AVF 333 302 0.093 424 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 740 740 0.090 692 14.0 0 x 0 VinIFix st6 Peak AVF 258 232 0.093 473 10.0 0 x 0 VinIFIx st5 2015-Oct-20 16:12:57 .` 4111- wrightsoft Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 .A_'P ...onstruction\Toff Brothers\Terrano 3058 Left.nip Calc=MJ8 Front Door faces: W Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb7 Ox 0 285 272 129.7 0.108 363 12.0 Ox 0 VIFx rt1 rb2 Ox 0 163 128 155.2 0.090 207 12.0 Ox 0 VIFx rt1 rb8 Ox 0 292 340 137.2 0.102 974 8.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 740 740 0.090 692 14.0 0 x 0 VinIFix I 2015-Oct-20 16:12:57 e�.`^� wrightsofr Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 19LCA ...onstruction\Toll Brothers\Terrano 3058 Left.rup Catc=MJ8 Front Door faces: W Job: Lot 9 AB McGOtiVan'S Duct Sy stem Summary Date: Heating&Air ,) Conditioning ^1. • Main By: Stephen hen Barber " """'"" ., McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey©mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merton,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904) 217-0739 Fax: (904) 814-8173 Web: www.tollbrothers.com Email: smerten @tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.246/0.144 in H2O 0.246/0.144 in H2O Lowest friction rate 0.087 in/100ft 0.087 in/100ft Actual air flow 740 cfm 740 cfm Total effective length (TEL) 448 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 3 h 629 37 27 0.120 4.0 Ox 0 VIFx 20.3 185.0 st9 Bedroom 2 c 2406 131 151 0.087 7.0 Ox 0 VIFx 47.2 235.0 st8 Bedroom 3 c 1858 114 117 0.125 7.0 Ox 0 VIFx 12.1 185.0 st9 Laundry c 181 9 11 0.127 4.0 Ox 0 VIFx 14.0 180.0 st9 Loft c 2315 108 146 0.088 7.0 Ox 0 VIFx 45.1 235.0 st8 Master Bath h 1756 103 89 0.122 6.0 Ox 0 VIFx 17.0 185.0 st7 Master Bedroom h 1637 96 80 0.120 6.0 Ox 0 VIFx 19.0 185.0 st7 Master Bedroom-A h 1637 96 80 0.121 6.0 Ox 0 VIFx 18.0 185.0 st7 Toilet h 190 11 7 0.119 4.0 Ox 0 VIFx 20.7 185.0 st7 Walk-In 1 h 592 35 31 0.124 4.0 Ox 0 i VIFx 13.2 185.0 st9 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st8 Peak AVF 240 297 0.087 545 10.0 0 x 0 VinIFIx st7 st7 Peak AVF 546 554 0.087 705 12.0 0 x 0 VinIFIx st2 st9 Peak AVF 194 186 0.120 440 9.0 0 x 0 VinIFIx st2 st2 Peak AVF 740 740 0.087 692 14.0 0 x 0 VinlFlx 2015-Oct-20 16:12:57 :` wrightsoft` Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 3 i ...onstruction\Toll Brothers\Terrano 3058 Left.rup Calc=MJB Front Door faces: W Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb6 Ox 0 208 181 153.4 0.094 194 14.0 Ox 0 VIFx rt2 rb3 Ox 0 119 152 165.5 0.087 345 9.0 Ox 0 VIFx rt2 rb5 Ox 0 186 175 161.9 0.089 420 9.0 Ox 0 VIFx rt2 rb4 Ox 0 227 232 162.6 0.089 295 12.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk r12 Peak AVF 740 740 0.087 530 16.0 0 x 0 VinIFIx 2015-Oct-20 16:12:57 ` Wrightsoft Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 4 AC ...onstruction\Toll Brothers 1Terrano 3058 Left.rup Calc=MJ8 Front Door faces: W