Loading...
2269 N FAIRWAY VILLAS LN - HURRICAN SHUTTERS „ rvf j �' '` , CITY OF ATLANTIC BEACH ., -r ■l 800 SEMINOLE ROAD j V: `` - �` '-”yr ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 WINDOW AND/OR DOOR PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-WIND-2562 Job Type: WINDOW AND/OR DOOR Description: HURRICANE SHUTTERS Estimated Value: $1,160.00 Issue Date: 11/12/2015 Expiration Date: 5/10/2016 PROPERTY ADDRESS: Address: 2269 N FAIRWAY VILLAS LN RE Number: 169398-1090 PROPERTY OWNER: Name: SKOCIK, COLLIN R &AMY L, * Address: 269 N FAIRWAY VILLAS LN GENERAL CONTRACTOR INFORMATION: Name: CUSTOM STORM SHUTTERS DIRECT Address: 826 HULL RD QA MICHAEL EDWARD O'CONNELL Phone: - - PERMIT INFORMATION: FEES: PLAN CHECK FEES $27.90 BUILDING PERMIT FEE $55.80 STATE DCA SURCHARGE $2.00 STATE DBPR SURCHARGE $2.00 Total Payments: $8730 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ►il r� City of Atlantic Beach 's'r l APPLICATION NUMBER d .4.40,;\ Building Department (To be assigned by the Building Department.) r. 800 Seminole Road ) Atlantic Beach, Florida 32233-5445 13 —WI f _ G z Phone(904)247-5826 • Fax(904)247-5845 9%- E-mail: building-dept @coab.us I d Date routed: /Z-C) / (S City web-site: http://vvww.coab.us 4 APPLICATION REVIEW AND TRACKING FORM Property Address: ZZa° . RLoe t( Department review required YerlS,Io v t LL S C� Buildinq� Applicant: Ca.S 7-p tw. S YC)Rvh S t-torrERS Planning &Zoning Tree Administrator Project: Hu R Rt o fl-NE S�{ U Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature • Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental P rotection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers — Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPL ATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: UILDIN.5 PLANNING & ZONING �~— Reviewed by: /7)4 Date://"6 '1 J TREE ADMIN. Second Review: ['Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. Comments: Reviewed by: Date: • Revised 07/27/10 BUILDING PERMIT APPLICATION OFFICE COPY CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach, FL 32233 Office(904)247-5826 Fax(904)247-5845 5— (N(J - ZG' Job Address: 224 9 N 0; Ln Permit Number: _ Legal Description 3R-1108-AS-2c)6 Wise Wisee.k.f th 166 Co/ IFS Parcel# / 0 35$-/0`}0 Floor Area of Sq.F't. Sq.F't Valuation of Work$ /,/6 0.tra Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial dielarent If an existing structure,is a fi e.s rinliler system installed?(Circle one): es No N/A Florida Product Approval# 1' L- 3 Sc) -j 7 For multiple products use product approval form Describe in detail the type of work to be performed: .Til,.Sta!/ 4.1 Arco c i ;o- Lurr i car.e_ S lu..-if r.t..s Property Owner Information: Name: co/[;h .4ies,y S/rocs - Address: 2,241 44. &Jay VI-114s e.4 City An_ar rtc. 1ecs. State Zip 312,53 Phone 904-2.2(,- iI/l0 E-Mail or Fax#(Optional) Contractor Information: Company Name:in44576.1 SA.Lepi S4.t cz Ca-wit Qualifying Agent: /Y(i a act e- 0 Conn a/J Address: 826 !au 11 R d City ei.kar,d2 Bcpc& State Zip 3Z/74 Office Phone 904 GL q S923 Job Site/Contact Number Fax# State Certification/Registration# CG C Is-14-114 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void f work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6)months at any time Oler work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs, Wells,Pools,Furnaces,Boilers,Healers, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUJR NOTICE OF COMMENCEMENT. I hereby certify that 1 have read and examined thisplication and know the same to be true and correct. All provisions o • s a ' ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to • /'utho to viola c' el the provisions of any other federal,state, or local law regulating construction or the performance of construction. AI./.14k 1 /i'J• i Signature of Owner /L Signature of Contracto �► _.ri nn � iii Print Name C01( OG 4 Print Name _AL" 4 I IQIL _ Sworn to and subscribed before me S orn o and su t .'•-d •-fo - me r thi G Day of l j / ,20 l f thi Day • 'a- o to 4. 20-6-J �o vi/� AVMS No ublic sia . sSION*FF 924951 I `$P �„ CONNELL d:74 PArn L.a ?� EXPIRES:October 6,2019 •, .4 Commission#EE 195635 -0451;.: Bonded inn,Novi Pic Underriters evised 01.26.10 • ' Expires June 8,2016 :.„„ 9ondtd1MiTIWFM1Mauranot 800364019 • Florida Building Code Online Page 1 of 2 . F.DRtD4 OLpAq!tflM'4..V Business & Professional Regulation O F F I V CC .. ® J .w _.`44, _` ' rag El Eff,,sou,OQPRI OBPR DiVISfONE CO:TA OOBPR loaJa Depaffl nt( BQS tome ' Log In !User Registration : Hot Tapia I Submit Surcharge : Stats&Facts ' Publications ' FBC Staff &CIS Site Map Links Search Busi'nWes Product Approval Professi�l Pubkc User Regulation Product Approval Menu>Product or Appllcatio 5_5u th>App'.icahon Lest>Application Detail /OFF1Cr.C."-e. FL* FL389-R7 sE..R£rp r, Revision Application Type Code Version 2010 Application Status Approved Comments Archived Product Manufacturer American Shutter Systems Association,Inc. Address/Phone/Email 4268 Westroads Drive West Palm Beach, FL 33407 f (561)209-8263 bfeeley@easternmetal.com L.. Authorized Signature Bill Feeley L Irodriguez @eastemmetal.com (7 c ty s Technical Representative / i Address/Phone/Email A� (/ Quality Assurance Representative Address/Phone/Email A..< Category Shutters \ j'1/4".' - Subcategory Accordion ' t tr•-• Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ,i Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Walter A..Tillit,Jr. P.E. the Evaluation Report Florida License PE-44167 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2017 Validated By John W. Knezevich,PE V Validation Checklist- Hardcopy Received Certificate of Independence FL389 R7 COI ASSA INC CERT.IND. HV3 14-0428.02 DRWG13- 031.pdf Referenced Standard and Year(of Standard) Standard Year ASTM E-1886 2005 ASTM E-1996 2005 ASTM E-330 2002 TAS 201, 202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL389 R7 Equiv LETTER CERTIFY ASTM E 1996.pdf Sections from the Code file:///C:/Users/Mike/Documents/Eastern%20389%20Accordions%20Product%20Approval.... 2/7/2015 , Florida Building Code Online Page 2 of 2 1 Product Approval Method Method 1 Option D Date Submitted 05/05/2014 Date Validated 05/05/2014 Date Pending FBC Approval 05/06/2014 Date Approved 06/23/2014 Summary of Products FL# Model, Number or Name Description 389.1 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks Blade 3-(Non-HVHZ)-Drwg 13- (top and bottom)for storm protection 031 Limits of Use Installation Instructions Approved for use in HVHZ:No FL389 R7 II ASSA IN(2B_G__.13-031 HV3 NHVHZ.pdf Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida Inc. Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Level"D". Max span is 12'-7"for 35 FL389 R7 AE ASSA INC PROD.EVAL.REP. HV3 14- psf positive ASD load and 13'-0"for 35 psf negative ASD 0428.02 DRWG13-031.odf load for one specific condition shown in span tables. Max Created by Independent Third Party:Yes span versus load varies with Blade 1 or Blade 1 and 1A working in unison,as well as existing structure condition. See sheet 5 for schedules showing appropriate values. 389.2 Bertha HV Accordion Shutter-Blade Extruded aluminum interlocking blade,retained by tracks 1 Only-(Non-HVHZ)-Drwg 11-192 (top and bottom)for storm protection units of Use Installation Instructions Approved for use in HVHZ: No FL389 R7 II ASSA drwq 11-192.pdf Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida Inc. Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Large missile level"D". Max.Span is 16'-0"for 30 FL389 R7 AE ASSA Productevaluationreportdrwg11192.pdf p.s.f negative ASD load depending on centermates and Created by Independent Third Party:Yes locking rod configuration for the HV1 blade,8'-0"for+64, -72 p.s.f.load for HV blade for Keystone mountings 7'-0"for • +75,-75 p.s.f.for metals stud mountings and 8'-0"for 110 p.s.f.for HV1 and HV1A working in unison. See sheets 7, 11 and 20 respectively of installation drawings for other spans and pressures. 389.3 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks COMBO-(Non-HVHZ)-Drwg 11- (top and bottom)for storm protection 194 Limits of Use Installation Instructions Approved for use in HVHZ:No FL389 R7 II ASSA DRWG 11-194,_pdf Approved for use outside HVHZ: Yes Verified By:American Test Lab of South Florida Inc. Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Large missile. Max. 16'-0"span at 30 p.s.f ASD load FL389 R7 AE ASSA Product evaluation report drwq 11 for Blade 1 and 18'-0"for Blade 2. See schedules on sheet 194.pdf 12, 25 and 28 respectively Created by Independent Third Party:Yes fBack) INextl Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AAJEEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement:: cessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mad.if you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee ruder Chapter 455,F.S.,please click re Product Approval Accepts: ✓✓ security m yni e s Credit SAFE fi 1 e:///C:/Users/Mi ke/Documents/Eastern%203 89%20Accordion s%20Product%20Approval.... 2/7/2015 CUSTOM STORM SHUTTERS D I R F. C T Property Information Building Information • Owner: skocik Collin Wind Zone: 130 MPH. Address: Exposure Category: B Minimum Building Dimension: 50 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Max Positive Max Negative Number Pressure(psf) Pressure(psf) 1 22.8 -24.4 2 22.8 -24.4 Prepared in accordance with:ASCE 7-10.Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of I N 2 2 > > O 0 O 0 O 0 a a 0 0 0 CO N - 9 a skocik Collin s. o N o 7 CUSTOM STORM SHUTTERS N m I) I R I: C T 1 L inimimmusio) OFFICE ' 3PY CUSTOM STORM SHUTTERS D I R EC T Property Information . : . •• Owner: skocik Collin Wind Zone: 130 MPH. Address: Exposure Category: B Minimum Building Dimension: 50 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Max Positive Max Negative Number Pressure(psf) Pressure(psf) 1 22.8 -24.4 2 22.8 -24.4 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1 5 C D D 8 8 Q Q O csa r"- Ftr p of 9, skocik Collin 411C--- I"",00) E e OD O N z N o D r CUSTOM STORM SHUTTERS N CT m 17 I Ii 1 C T