1691 ATLANTIC BEACH DR - ENERGY SHEETS -- - - I - FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Builder Name: Toll Brothers Lot 16 Project Name: O 3114 Right W Permit Office: Atlantic Beach r Street: Lot 16 Atlantic Beach permit Number: Cr O P City,State,Zip: Atlantic Beach ,FL, Jurisdiction: 261300 Y Owner. Toll Brothers Design Location: FL,Jacksonville Types 4051.7 sgfL) Insulation Area New(From Plans) 9. Wall Typ ( R=u9.0 384A Area ft2 1. New construction or existing a.Frame-Wood,Exterior Single-family b.Frame-Wood,Adjacent R=13.0 205.00 ft2 . 1 2. Single family or multiple family c.N/A R= R= f2 3. Number of units,if multiple family d.NIA 4 Types (1536.0 sqft.) Insulation Area 4. Number of Bedrooms 10.Ceiling Typ ( 5. Is this a worst case? 0 1536.00 ft2 R= b.N/A 3067 No a.Under Attic(Vented) R=38, ft2 R= ft2 6. Conditioned floor area above grade(ft2) c.N/A R ft2 Conditioned floor area below grade(ft2) 0 11.Ducts 6 512 7. Windows(600.8 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor Dbl,U=0.34 600.83 ft2 a. U-Factor. kBtulhr Efficiency SHGC: N/A ft2 12.Cooling systems to h SE Efficiency 00 b. U-Factor: NIA � a.Central Unit SHGC: c. U Factor. N/A ft2 13.Heating systems kBtuthr Efficiency • d. U-Factor: N/A ft2 SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: 4.767 ft. Area Weighted Average Overhang Depth: 0 270 14.Hot water systems Cap:1 gallons Area Weighted Average SHGC: a.Natural Gas Tankless EF:0.590 8. Floor Types (3067.0 sqft.) Insulation Area • a.Slab-On-Grade Edge Insulation R=0.0 1531.00 ft2 b. None c.otther Conservation features R=0.0 1416.00 ft2 Pstat b.Floor Over Other Space R= 120.00 ft2 15.Credits her(see details) Total Proposed Modified Loads: 77.50 PASS Glass/Floor Area: 0.196 Total Baseline Loads: 82.97 'M..Y•I...i Review of the plans and �`'Q1::•�-•-�.•�••••-36' '• I hereby certify that the plans and specifications covered by specifications covered by this =`�1'-%i `>;� �''.Q•4'~+` Cis calculation are in compliance with the Florida nergy calculation indicates compliance '/, , ;,;_..7.' '-•.� Code. / Code. ate• --• 's� '' with the Florida Energy cx��:,� ._ ®,:„ ., I _ •4- Before construction is completed 0,_ _,,e a DATE: aY: ��" this building will be inspected for :c9 • DATE: �� 9��- compliance with Section 553.908 •*1; `�. �`•Florida Statutes. 4 '- I hereby certify that this building as designed,is in compliance -, c,.....,...•..••,, with the Florida Energy C••.e • BUILDING OFFICIAL: `���� OWNER/AGENT: q . 5 • DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 8402.4.1.1 and an envelope leakage P test report in accordance with R402.4.1.2. 10/9/2015 8:24 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 _ - - F O R M R405-2014 PROJECT 4 Address Type: Street Address Bedrooms: Lot# Title: 7errano 3114 Right W e User Conditioned Area: 3067 Block/SubDivision: Building Type: Total Stories: 2 Owner: Toll Brothers No PlatBook: 1 Worst Case: Street: Lot 16 Atlantic Beach #of Units: Rotate Angle: 0 Duval Builder Name: Toll Brothers County: Cross Ventilation: No Coo State,Zip: Atlantic Beach Permit Office: 261300 Beach Whole House Fan: No FL, Jurisdiction: 261300 Family Type: Single-family New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp / TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range `i Design Location 70 75 1281 49 Medium FL,Jacksonville FL_JACK50NVILLE_INT 2 32 93 r BLOCKS Number Name Area Volume 1 Block1 3067 29134 SPACES Bedrooms lnfillD Finished Cooled Heated Name . Area Volume Kitchen Occupants Yes Yes Number 1 1 1 Yes 1 Main 1531 15310 Yes 1536 13824 No 4 3 1 Yes Yes Yes 1 I 2 2nd Floor 1 FLOORS 120 ft Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet_____y___ # Floor Type Space -- --_ 0 0 1 ft2 0 2nd Floor _____y___ 1 Floor over Garage _r 0 0 1 197.4 ft 0 1531 ft2 1/ 2 Slab-On-Grade Edge Insulatio Main V 0 0 1 1416 ft2 0 % 3 Floor Over Other Space 2nd Floor --- ---- ROOF • Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Materials Area Area Color Absor. Tested Tested lnsul. (deg) # Type • 1 Gable or Shed Composition shingles 1788 ft2 344 ft2 Medium 0.8 N 0.9 No 0 22.6 1 ATTIC J Ventilation Vent Ratio(1 in) Area RBS 1RCC # Type 1651 ft2 N N 1 Full attic Vented 300 10/9/2015 8:24 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 1 Iv Framing Frac Truss Type Space R-Value Area Wood # Ceiling Type 1536 ft2 0.11 ___\___ 1 Under Attic(Vented) 2nd Floor 38 Adjacent Height Sheathing Framing Solar Below I Space - -Cavity Width 9 39 . _ 8 9 0 357.0 ft, 0 0 25 0.8 0 1 W Exterior Frame-Wood 2nd Floor 19 0 0.25 0.8 0 Main 19 19 2 10 0 191.7 ft2 2 W Exterior Frame-Wood 19 64 6 9 0 580.5 ft2 0 0.25 0•8 0 I 2nd Floor 0 , l 3 N Exterior Frame-Wood 2 10 0 691.7 ft2 0 0.25 0.8 I VI Main 19 69 0 0.25 0.8 0 4 N Exterior Frame Wood 39 8 9 0 357.0 ft2 2nd Floor 19 = 0 0.25 0.8 0 5 E Exterior Frame-Wood 39 8 10 0 396.7 ft Main 19 0 I 6 E Exterior Frame Wood 64 6 9 0 580.5 ft2 0 0.25 0.8 / 2nd Floor 19 2 0 0.25 0.8 0 V 7 S Exterior Frame-Wood 19 69 2 10 0 691.7 ft �g S Exterior Frame-Wood Main z 0 0.25 0.01 0 Main 13 20 6 10 0 205.0 ft /g W Garage Frame Wood DOORS Height Area i Storms U-Value Width I # Ornt Door Type Space Ft In Ft In None .6 3 8 24 ft2 Main 1 W Insulated 39 2 8 8 21.3 ft2 2 W Wood Main None WINDOWS Orientation shown is the entered,Pro•osed orientation. Overhang I J • Wall Area Depth Separation Int Shade Screening NFRC U-Factor SHGC None Exterior 5 # W ID Frame Panes 12.0 ft2 1 ft 0 in 1 ft 6 in 1 W 1 Vinyl Low-E Double Yes 0.34 0.27 None Exterior 5 - Yes 0.34 0.27 30.0 ft2 1 ft 0 in 1 ft 6 in 2 W 1 Vinyl Low-E Double None Exterior 5 i Yes 0.34 0.27 36.0 ft2 1 ft 0 in 1 ft 6 in 3 W 2 Vinyl Low-E Double None Exterior 5 / 0.34 0.27 20.0 ft2 1ft 0in 1ft 6in � 4 N 3 Vinyl Low-E Double Yes None Exterior 5 Yes 0.34 0.27 20.0 ft2 1 ft 0 in 1 ft 6 in �/ 5 N 3 Vinyl Low-E Double None Exterior 5 Yes 0.34 0.27 128.0 ft2 8 ft 2 in 1ft 6in 6 E 6 Vinyl Low-E Double None Exterior 5 Yes 0.34 0.27 6.0 ft2 1 ft 0 in 1ft 6in 7 N 3 Vinyl Low-E Double None Exterior 5 Yes 0.34 0.27 20.0 ft2 1 ft 0 in 1 ft 6 in 8 N 4 Vinyl Low-E Double None Exterior 5 Yes 0.34 0.27 15.0 ft2 7ft 2in 1ft 6in 9 W 1 Vinyl Low-E Double None Exterior 5 0.34 0.27 60.Oft2 8ft2in 1ft 6in 10 E 6 Vinyl Low-E Double Yes None Exterior 5 0.34 0.27 96.0 ft2 8ft2in 1ft6in 11 E 6 Vinyl Low-E Double Yes None Exterior 5 Yes 0.34 0.27 6.0 ft2 1ft 4in 1ft 6in 12 E 5 Vinyl Low-E Double None Exterior 5 "T Yes 0.34 0.27 15.0 ft2 1 ft 0 in 1 ft 6 in V 13 E 5 Vinyl Low-E Double None Exterior 5 33.3 ft2 5ft0in 1ft6in 14 E 5 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 15 S 7 Vinyl Low-E Double Yes 0.34 0.27 None Exterior 5 Yes 0.34 0.27 8.0 ft2 1 ft 0 in 1 ft 6 in 16 S 7 Vinyl Low-E Double None Exterior 5 Yes 0.34 0.27 45.0 ft2 1 ft 0 in 1 ft 6 in L 17 S 8 Vinyl Low-E Double None Exterior 5 '-V Yes 0.34 0.27 4.5 ft2 1 ft 0 in 1 ft 6 in 19 S 2 8 Vinyl Low-E Double None Exterior 5 19 W 2 Vinyl Low-E Double Yes 0.34 0.27 16.0 ft2 1 ft 0 in 1 ft 6 in 10/9/2015 8:24 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 . . _____. - ----------\ FORM R405-2014 GARAGE lif Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation # Floor Area Ceiling Area 10 ft 0 I 1 653 ft2 420 ft2 83 ft • INFILTRATION 1 d SLA CFM 50 ELA Method EqLA ACH ACH 50 # Scope 250.66 .2861 5 1 Wholehouse Proposed ACH(50) .000302 2427.8 133.28 HEATING SYSTEM lir Efficiency Capacity Block Ducts Electric Subtype 1 sys#1 # System Type 1 Electric Heat Pump None HSPF:8.2 42 kBtu/hr COOLING SYSTEM WV Efficiency Capacity Air Flow SHR Block Ducts Subtype sys#1 # System Type SEER:14 42 kBtu/hr 1260 cfm 0.700000 1 y 1 Central Unit Split HOT WATER SYSTEM RV SetPnt Conservation Location EF Cap Use se None # System Type SubType 55.1 gal 120 deg 1 Natural Gas Tankless Exterior 0.59 1 gal SOLAR HOT WATER SYSTEM Collector Storage FEF FSEC System Model# Collector Model# Area Volume Cert # Company Name ft2 None None DUCTS HVAC# Air CFM 25 CFM25 RLF Heat Cool Supply— —Return Handler TOT OUT QN # Locatioo n R-Value Area Location Area ea Leakage Type Default 1 Attic 6 512 ft2 Attic 213 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1 1 i Compliant Software Page4of5 10/9/2015 8:24 AM EnergyGauge®USA FIaRes2014 Section R405.4.1 Comp'l Air FORM R405-2014 TEMPERATURES Ceiling Fans: Nov Dec Programable Thermostat:Y Sep Oct Nov Dec Aug Feb Mar Apr May Jun Jul Aug Sep t Oct Nov Dec Venting Jan Mar May Jul Aug Sep Heating [X Jan ��Feb [XI Mar �X�Apr May n Jun Venting L�Jan Hours 10 11 12 Thermostat Schedule: HERS 2006 Reference 2 3 4 5 6 8 9 Cools gle Type AM 78 78 78 78 78 78 78 78 78 78 80 80 Cooling(WD) PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM M 78 78 78 78 78 78 78 68 68 68 68 66 68 AM 66 66 66 66 8 68 68 68 68 68 68 66 66 Heating(WD) PM 68 68 66 66 66 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 68 68 68 68 68 i i • I 10/9/2015 8:24 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 . . ____ ___ __ ___ . ._ .\ FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance index,the more efficient the home. Lot 16 Atlantic Beach, Atlantic Beach , FL, 9. Wall Types Insulation Area New(From Plans) R=19.0 384 Area ft2 1. New construction or existing a.Frame-Wood,Exterior R=19.0 205.00 ft2 Single-family b.Frame-Wood,Adjacent ft2 2. Single family or multiple family c.N/A R 1 ft2 3. Number of units,if multiple family d.N/A R 4 10.Ceiling Types Insulation Area 4. Number of Bedrooms R=38.0 1536.00 ft2 No a.Under Attic(Vented) ft2 5. Is this a worst case? b.N/A R= ft2 c.N/A R 6. Conditioned floor area(ft2) 3067 R ft2 a. U-Factor: Dbl,U=0.34 Description Area 11.Ducts 6 512 7. Windows' 600.83 ft2 a.Sup:Attic,Ret:Attic,AH:2nd Floor SHGC: SHGC=0.27 ft2 b. S Factor: N/A kBtu!hr Efficiency 12.Cooling systems 42.0 SEER:14.00 SHGC: ft2 a.Central Unit C. U-Factor. N/A SHGC: ft2 kBtu/hr Efficiency d. U-Factor. N/A 13.Heating systems SHGC: 4.767 ft a.Electric Heat Pump 42.0 HSPF:8.20 . Area Weighted Average Overhang Depth: 0 270 Area Weighted Average SHGC: 14.Hot water systems Cap:1 gallons 8. Floor Types Insulation Area a.Natural Gas EF:0.59 a.Slab-On-Grade Edge Insulation R=0.0 1531.00 ft2 R=0.0 1416.00 ft2 b. Conservation features b.Floor Over Other Space 120.00 ft2 None c.other(see details) R= Pstat 15.Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building �."'' i1XE.sT."..=•.. y'rAiQ /•-c a' O'�.. Construction through the above energy saving features which will be installed(or exceeded) �,;� fr _ { in this home before final inspection. Otherwise, a new EPL Display Card will be completed re +r`+r ,,, ,: ;,,,,, ,o features. d. '°""__ cr based on installed Code co for, `w I. Date: I a . " r .a L. Builder Signature: AI .�► 322 -* �'''9 �Y �* C C.VI Zip: -L .o .' ,�.• /,!� Dr. City/FL p: F ``4.. .. w�' `,,.-.. Address of New Home: ( l I . a 1 your home may qualify for energy efficient *Note: This is not a Building Energy Rating. If your Index is below Rang. Contact the EnergyGauge Hotline at(321) mortgage(EEM)incentives if you obtain a Florida EnergyGauge 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/9/2015 8:24 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 I FORM 8405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods Permit Number: ADDRESS: Lot 16 Atlantic Beach Atlantic Beach ,FL, MANDATORY REQUIREMENTS See individual code sections df g full shall that an energy performance level(EPL) ❑ approval require that t an ten for performance Florida law 401.3 Energy Performance and Level certified by display card be(Mandatory). [Section card.9 completed and uesifreq requires the builder display p accurate o and included as correct asfan final app o each sal le col rac eor b thipr s components [Section ld reside, ial bull Stgs.T requires tpl Ecareontainsrnformat on indicating the energy to each sales builder accurately for encreflecs the plans nonalld in residential nit.The The EPL display sy of the EPL display and card can the found a C. installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by and specifications submitted to demonstrate compliance for the building.A copy R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of ❑ Sections R402.1 through R402.4.4. with Sections R402.4.1.1 and R402.4.1.2.The O 8402.4.1 Building thermal envelope. The building thermal envelope shall comply sealing methods between dissimilar materials shall allow for differential expansion and contraction. • accordance.1 Installation. wi tathe/ manufacturer's The tier's°instructions e ndlthe cr ter a listed envelope n Table Table applicable able to installed construction. Where with t the code official, approved third party shall inspect all components and verify compliance. Where required by the code official,an app 5 air • R402.4.1.2 hang changes per hour in The building or dwelling, d 3tairrchanges per hour in Climate Zones 3 through 8.Testing shall be conducted with a bloges per door hour in Climate ssu o f 0.2 inches 1 a conducting the test and provided to the code a blower door at a press ritten report of the esul s of Pascals).Where required by the code shall be signed by the party conducting tingnh shall and prconducted by an approved third n partyl A written P official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Heating doors ndreooling systems,ventilation installed systems t the time of the test,shall bettumed off;shall and closed and sealed; 5.Heating and cooling 6.Supply and return registers,if installed at the time of the test,shall be fully open. o R402.4.2 Fireplaces.New wood-buming fireplaces shall have tight-fitting tig ht-f i me an outd infiltration outdoor O ion air and ,skylights and sliding glass doors shall have an rate of no more than 0.3 cfm pe r square fo ot(1.5 Uslrn2),and more (2.6 e tested according to NFRC 400 or AAMANVDMA/CSA 10111.S.2lA440 by an a ceditedndepende t laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O between Recessed lighting. Recessed spaces.luminaires All recessed luminair es shall be IC-rated and labeled as having an air leakage rate not between conditioned and unconditioned s)w P ressure differential.All recessed more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)p luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance.heat shall have controls that,El . Heat during defrost,pP that,,except ept during defrost,prevent supplemental heat operation boxes and building ng cav'dies that form the primary aatconta containment ❑ passage aYs for (Mandatory)All systems s s,air shall belconsidered and filter b dot con accordance with Section for air distribution 2 of h Provisions of this code and shall be shown to meet lduct tightness ecriteriia by sealed in actor c ion and plenum chambers, with Section C403.2.7.2 of the Commercial or rough-in testing below. rater certified in accordance with Section Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either ith r of the feet(9 29 m2)of conditioned floor area 1. when tested a ion test pressure differential erentia shall inches less than or 5qua►a 4 ss cfm t e(113 n Umiy)p when tested at a pressure differential of 0.1 d during the testacross the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise seale 9 2, at a pressure test:Total leakage shall be less w.g. 25 or a across s 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm at a pressure differential of 0.1 inches wig.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If t (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. i 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/9/2015 8:24 AM EnergyGauge®USA FlaRes2014 -Section 8405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 8403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used asdus l of carrying fluids above 105°F(41°C) ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable or below 55°F(13°C)shall be insulated to a minimum of R-3., on of piping insulation. Piping insulation exposed to weather shall be parotected from that can damage,suer including tat degradation caused the •0 by sunlight,t,moisture, p P 9 by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from material.Adhesive tape shall not be permitted. 8403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily ❑ accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat w wa traps andaupwa d bend of at least 3%inches External in the hot water distribution I ne and cold water available heat trap possible downward and p to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies p R403.4.4.1 Storage water heater temperature controls a with automatic temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipp capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). o 8403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied provided supplied to the main burner(s) to electric service systems to be turned off.A separate valve shall be rovided to permit the energy of combustion types of service water heating systems to be turned off. type i um efficiencies installed. iesof O R403.4.4.2 Water heating equipment Water heating equipment in shall meet the for the typinimum P ciencies o Equipment C404.2 used in to provide 4 of the Florida unc Building Code,Energy Equipment used to provide fieating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. factor of the system..The of heating energy systems.tor of Solar systems m shall be determined from the production lorida Solar Energy gy Ce ter Directory ofergy Certified of the ar Systems.Ts. solar Certified Solar Standard Solar,Solar Domestic Hot Water System and Component Test Protocol, Methods for no installed osolar waters and SRCC Stands heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation tiwn that meets he requirements ventilation.the ❑ Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable, Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. O R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. • • Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. O R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3• If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air R- 0 otherhall be insulated to a . minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in d tea ng a with A C calculation based on the es, I equipment loads calculated in accordance with ACCA Manual J or other approved based on units tea the shall be submitted along with the building. sensible and total cooling capacities at the design conditions and number of the outdoor indoor units(S Section system) whichib f in equipment tt s sizing.System sizing calculations designer hall not intclude loads rcreated by local intermittent mechanical ventilation which affect such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load, closest available ns 1.15 times size provided rby than the total load calculated product lines.The according orresponding latent capacity of the Section 403.6,or the equipment shall not be less than the calculated latent load. Page 2 of 3 10/9/2015 8:24 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 shat not be used equipment sizing.capacity. Manufacture's expanded performance data shall be used to select cooling-only rating-test qipment value Thisnd shall not shall all b for us equipment sioo g load sagobe used ri select t coolnperatu eforp water-source equipment),the blower ocfm provided rby the temperature for the data, load calculation(or entering water temp the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry side temperature if the a shall be for sr is a indooddr an bulb and relative lative humidity used for the load calculation and shall be adjusted for ret gains Exceptions: • 1. Attached single- sandimelti fabut not de n ial equipment u pe cen i ghat be selected so that its cooling capacity is less than the calculated 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 termi en Extra sis capacity a antic pa ed additional onal loads caused by major entertainment events, cooling or heating have equipment zed or controlled on to an intermittent basis, options: • prevent continuous space cooling or heating within that space by one or more of the following op 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. with Sections • R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply C403 and C404 of the Commercial Provisions in lieu of Section R403. • R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls ua{acontrol that will allow shutoff when the outdoor temperature is above 40 F.55°F,and no precipitation is falling and an automatic or m an ID R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through 8403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. o R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. 840ma.1.Gas and 82 percent pool for heaters manufactured gas-and oil-fired after April 16,20113 and space heaters shall have a minimum when tested In accordance with ANSI Z 21.56. Pool heaters to efficiency Pool heaters fired by natural gas or LP gas shall not have pool continuously shall have apmin mu m COP of 4.0 when tested in accordance • with AHRI 1160, pump pool nd heaters.d R Heat pump p with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature. i s are not required'to meetth ndepenent standard. is required to verify procedure compliance.Geothermal swimming p ool heat pumps p preset schedule Times shall be installed l ed switches all heaters and pumps.Heaters,pumps and motors that have built in timers shalll be deemed in to a preset schedule shall be i • compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipp ed with a vapor retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: e Outdr pools deriving ovn over operating 0 pr ent of the energy for heating from site-recovered energy,such as a heat pump or solar energy sourc ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required Fuel to utilize high-tens lamps.systems have continuously burning pilot lights O R404.1.1 Lighting equipment(Mandatory). 9 ❑ R405.2 Performance ONLY. All NLY.ts Ceilings sinside all(have minimum insulation of R-19.shall single insulated ssemby of the exposed deck and beam type or o R405.2.1 Performance concrete deck roofs do not have sufficent space,R-10 Is allowed. Page 3 of 3 10/9/2015 8:24 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com • FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Builder Name: Toll Brothers Project Name: Terrano 3114 Right W Builder Office: Toll Brothers Beach Street: Lot 16 Atlantic Beach Permit Number: City,State,Zip: Atlantic Beach ,FL, pe Perisdictiu 261300 Owner. Toll Brothers Design Location: FL,Jacksonville CHECK COMPONENT CRITERIA Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. �� Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. envelope. Exterior thermal walls shall substantial contact and co continuous alignment t with the aiirbarriertalled in Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim'oists Rim joists are insulated and include an air barrier. ME Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Where provided in lieu of floor insulation,insulation shall be permanently Crawl space walls attached to the crawispace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled Narrow cavities by insulation that on installation readily conforms to the available cavity s•aces. -\._,Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the buding thermal envelope shall be air tight,IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Efectrlcal/p hone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have gasketed doors Page 1 of 1 10/9/2015 8:25 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Builder Name: Toll Brothers Project Name: Terrano 3114 Right W Permi lde Office: Atlantic Brro Beach Street Lot 16 Atlantic Beach Permit Number. City,State,Zip: Atlantic Beach ,FL, pe Perisdictio 261300 Design Location: FL,Jacksonville Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n; R: CFM(50)' Single or Multi Point Test Data I I ELA; I I HOUSE PRESSURE FLOW: . EgLA. ACH: ACH(50): SLA: R402.4.1.2 Zones Testing. The air building changes per r intCl ma a be tested and verified as having an air Zones 3 through B.Testing shall be conducted with a blower door at air pressure of 0.2 hour in Climate Zones a and). 3 ae ehequi e p br approved third party.A written report of the results of the inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an app test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other • infiltration control measures; 2.Dampers including exhaust,Intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; . 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, l^ , ,� E_ ` o��, testing shall be conducted by an :�:, -, -' performance results demonstrate compliance 9 f���, to approved third party.A written F,;,nu i,,;, ,.-,,...s.-.-%.,;,.: _.„.0..,' ;,,, with Florida Energy Code requirements in report of the results of the test shall w _..4Q .°el®: accordance with Section R402.4.1.2. P _ ,._• _s..- a be signed by the third party V 4.�1-, conducting the test and provided to .. a, * the code official. +r ; SIGNATURE: "�-1,o.:.D WV.I'':,..+. PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 10/9/2015 8:25 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Softwar Page 1 of 1 ■ I Lot 16 AB MCGOwan'S Project Summary Job:Job: Lot 16 Heating&Air .. f? Main By: Stephen Barber Candit-oning�1? ":�.��::._,��, McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Notes: The Terrano Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 96 °F Inside db 21 °F 70 °F Inside db 75 °F Design TD 38 °F Design TD Daily range M M Relative humidity 48 gr/lb Moisture difference Heating Summary Sensible Cooling Equipment Load Sizing Structure 27581 Btuh Structure 21857 Btuh Ducts 4511 Btuh Ducts 5407 Btuh 0 Btuh Central vent(0 cfm) 0 Btuh Centra vent(0 cfm) 0 Btuh Blower 0 Btuh Humidification Btuh Piping 0 Btu n Equipment load 32092 Btuh Use manufacturer's data 1.01 Rate/swing multiplier Infiltration Equipment sensible load 29689 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Structure 3877 Btuh Fireplaces Ducts 816 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Are a 3067 3067 Equipment latent load 6234 Btuh Volume e 30360 30360 Air changes/hour(fN) 35923 Btuh Air changes/hour 0.28 0.15 Equipment total load Equiv.AVF (cfm) 142 76 Req.total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB04200G Cond CH14NB04200G AHRI ref 7835544 Coil FB4CNP042L00 AHRI ref 7835544 12 0 EER, 14 SEER Efficiency 8.2 HSPF Efficiency 2SEE Btuh Heating input Sensible cooling 28700 Btuh Heating output 40000 Btuh @ 47°F Latent cooling 41000 Btuh Temperature rise 27 °F Total cooling cfm Actual air flow 1367 cfm Actual air flow 1367 1367 cfmlBtuh Air flow factor 0.043 cfm/Btuh Air flow factor .050 cf H2O Static pressure 0.50 in H2O Static pressure 0.85 Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Oct-09 08:14:24 wrightsoft` Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 /ACC ...nstruction\Toll Brothers\Terrano 3114 Right.rup Calc=MJ8 Front Door faces: W „, ® First Floor AirC Breakfas 6 x 12 7” Bedroom 10x10 6x14 TI LN 7„ Family Roo. 8 I 12 x 12 li 9„ r 12 Ret Riser 14" s • C I\ 10" Sup Rise as 1 m► 14 Bat J 18 18x 8x4 3" Fan ., Kitcher T _ 4" ') Stall 12" 10x10 6' FR 10x1 8"r' J ••' 6x10 Butler Pan' 'antr' 6 L 8 x 4 Hall 4 'iv 10 x 6 Study 6x14 6" 8" Dining Roar Garagc Faye: I Scale: 1 : 89 Job#: Lot 16 AB McGowan's Heating & Air Conditioning,. Page 1 Performed by Stephen Barber for: Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.17 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Oct-09 08:15:41 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com Korey©mcgowansac.com Brothers\Terrano 3114 Right.rup www.tollbrothers.com smerten@tollbrothersinc.com . . 4. „ .: ..,,,,,......... 1,,, ir- Second Floor fi T 8x4 5" J Walk-In 1 12 x 6 Master Bedroo 14" 9" I 7" Bedroom 10x6 10x6 16x16Mi il 6„ 6 14" f 12 x 12 r• P.1 �� � r, 9 Sup Riser Ret Riser MT 8 Laund II,a.,,,, aj lle x 4x8 PM 10x10 P. 14" , � 10x6 9' t 5 VJ a J 10x10 18 Bath 3 Hall 8x4 - Master Batt 4' me VW 12 :H-• PJ Stair: 3"Fan - 3" Fan T 12x12 i<J 12x12 8 r 9,• 12x6 7„ Bedroom bonus s Loft 10 x 6 6x10 6 6" i 10 x 6 6" Open to FoyE Job#: Lot 16 AB Scale: 1 : 89 McGowan's Heating & Air Conditioning,. Performed by Stephen Barber for: Page 2 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.17 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Oct-09 08:15:41 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com Korey @mcgowansac.com ...Brothers\Terrano 3114 Right.rup www.tollbrothers.com smerten @tollbrothersinc.com - AB 16 McGowan s Duct System Summary Job:Date: Lot Lot 16 Heating&Air 1 By: Stephen Barber Conditionin9 �J Main,r <.,=r<: "„°■ irkUfge McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey @mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone:(904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Heating Cooling 0.50 in H2O 0.50 in H2O External sta pressure 0.11 in H2O 0.11 in H2O Pressure ssure lostic ses 0.39 in H2O 0.39 in H2O Available eturic pressure 0.266/0.124 in H2O 0.266/0.124 in H2O Lwely/rest friction rate turn available pressure 0.081 in/100ft 0.081 in/100ft L 1367 cfm 1367 cfm Actual air flow 482 ft Total effective length(TEL) Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Trunk Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Loft c 1241 35 62 0.095 6.0 Ox 0 VIFx 45.2 235.0 st5 Open to Foyer C 1332 61 67 0.094 6.0 Ox 0 VIFx 46.5 235.0 st5 Bedroom 3 C 1875 84 94 0.138 7.0 Ox 0 VIFx 13.1 180.0 st3 Bath 3 h 672 29 23 0.128 4.0 Ox 0 VIFx 22.7 185.0 st3 Bedroom 2 C 2176 95 109 0.094 7.0 Ox 0 VIFx 47.9 235.0 st5 Walk-In 1 C 784 30 39 0.141 5.0 Ox 0 VIFx 13.5 175.0 st3 Master Bath h 912 39 35 0.128 5.0 Ox 0 VIFx 22.5 185.0 st4 Toilet h 195 8 6 0.128 4.0 Ox 0 VIFx 22.1 185.0 st4 Master Bedroom C 1240 56 62 0.128 6.0 Ox 0 VIFx 22.0 185.0 st4 Master Bedroom-A c 1240 56 62 0.130 6.0 Ox 0 VIFx 20.1 185.0 st4 Laundry-A c 183 6 9 0.139 4.0 Ox 0 VIFx 16.5 175.0 st3 bonus C 1558 65 78 0.096 7.0 Ox 0 VIFx 43.1 235.0 st5 Bedroom 4 h 3144 134 108 0.114 8.0 Ox 0 VIFx 32.7 200.0 st8 Bath h 999 43 19 0.113 5.0 Ox 0 VIFx 39.8 195.0 st8 Breakfast h 3048 130 96 0.081 8.0 Ox 0 VIFx 83.3 245.0 st7 Kitchen h 1712 73 23 0.086 7.0 Ox 0 VIFx 68.2 240.0 st7 Family Room C 4306 134 216 0.119 9.0 Ox 0 VIFx 32.7 190.0 st8 Dining Room h 4594 196 186 0.087 9.0 Ox 0 VIFx 66.7 240.0 st7 Study h 1176 50 29 0.107 6.0 Ox 0 VIFx 49.2 200.0 st6 Hall 1-A c 846 39 42 0.104 5.0 Ox 0 VIFx 56.2 200.0 st6 Pantry h 137 6 2 0.087 4.0 Ox 0 VIFx 64.2 240.0 st7 2015-Oct-09 08:14:24 Page 1 '.....t; + wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 ...nstruction\Toll Brothers\Terrano 3114 Right.rup Calc=MJ8 Front Door faces: W 1 1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st7 Peak AVF 404 306 0.081 741 10.0 0 x 0 VinIFIx st6 st6 Peak AVF 494 377 0.081 629 12.0 0 x 0 VinIFIx st2 st8 Peak AVF 310 343 0.113 437 12.0 0 x 0 VinIFIx st2 sty Peak AVF 256 316 0.094 403 12.0 0 x 0 ViniFlx st4 st3 Peak AVF 149 166 0.128 376 9.0 0 x 0 VinIFIx st1 st4 Peak AVF 415 481 0.094 450 14.0 0 x 0 ViniFlx st1 st1 Peak AVF 563 647 0.094 463 16.0 0 x 0 VinIFIx st2 Peak AVF 804 720 0.081 752 14.0 0 x 0 VinIFIx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Trunk Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Openin g (in) rsb3 Ox 0 476 445 141.1 0.088 1078 9.0 Ox 0 VIFx rt5 rt3 rb3 Ox 0 156 176 130.0 0.096 398 9.0 Ox 0 VIFx rt3 rb5 Ox 0 72 87 117.1 0.106 198 9.0 Ox 0 VIFx rt1 rb1 Ox 0 169 196 124.5 0.100 560 8.0 Ox 0 VIFx rt1 rb4 Ox 0 103 103 116.6 0.107 96 14.0 Ox 0 VIFx rt5 rb9 Ox 0 328 275 99.1 0.125 601 '10.0 Ox 0 VIFx rt3 rb6 Ox 0 63 86 153.6 0.081 321 7.0 Ox 0 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt5 Peak AVF 804 720 0.088 1474 10.0 0 x 0 VinlFlx rt2 rt3 Peak AVF 291 349 0.081 326 14.0 0 x 0 VinIFIx rt1 rt1 Peak AVF 563 647 0.081 463 16.0 0 x 0 VinlFlx rt2 Peak AVF 804 720 0.088 752 14.0 0 x 0 VinIFIx 2015-0c1-09 08:14:24 Page 2 " wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 CC ...nslruction\Toll Brothers\Tenano 3114 Right.rup Calc=MJ8 Front Door faces: Manual S Compliance Report Job: Lot 16 AB IHCGOW$11'S p p Date: 9/25/15 Heating&Air __ ,+ ? Entire House By: Stephen Barber Conditioning McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey @mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 34786 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 3565 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 38351 Btuh Indoor RH: 50% Estimated airflow: 1333 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L++TXV Actual airflow: 1333 cfm Sensible capacity: 34786 Btuh 100%of load Latent capacity: 3565 Btuh 100%of load Total capacity: 38351 Btuh 100%of load SHR: 91% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 33559 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L++TXV Actual airflow: 1333 cfm Output capacity: 40000 Btuh 119%of load Capacity balance: 28 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1333 cfm Output capacity: 9.8 kW 100%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Sep-25 08:58:17 -f� wrightsaft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 CN ...Construction\Toll Brothers\3.5 TON Manual S.rup Calc=MJ8 Front Door faces: W