Loading...
Permit Siding 489 Aquatic 2012 * t 1 rJc, CITY OF ATLANTIC BEACH . x ' '. 800 SEMINOLE ROAD 1- ` r} ATLANTIC BEACH, FL 32233 r , , INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000101 Date 1/27/12 Property Address 489 AQUATIC DR Application type description SIDING PERMIT Property Zoning TO BE UPDATED Application valuation . . . • 5972 Application desc new siding Owner Contractor TODD LARRY. WCI GROUP, INC. 2444 BENTWATER DR W 1100 SHETTER AVE STE 203 JACKSONVILLE FL 32246 QA KEVIN PATRICK FITZGERALD JAX BEACH FL 32250 (904) 242 -4444 Permit SIDING PERMIT Additional desc . Permit Fee . . . 80.00 Plan Check Fee . . 40.00 Issue Date . . . Valuation . . . . 5972 Expiration Date . 7/25/12 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONA1 ELECTRIC CODE *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. Other Fees STATE DCA SURCHARGE 2.00 STATE DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 80.00 80.00 .00 .00 Plan Check Total 40.00 40.00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 124.00 124.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH I I I I I , ,,,,io 0 / 0 / 7 T g , , „. t�' W fs`: 800 SEMINOLE ROAD, ATLANTIC BEACH, FL 32233 A N , 'i OFFICE: (904)247 -5826 • FAX NO.:(904)247 -5845 r. ^.,. i , BUILDING - DEPT @COAB.US 40 =, ILDING PERMIT APPLICATION DUVAL COUNTY 1. JOB ADORE. = 2. VALUATION OF WORK: 3. SO. FT. UNDER ROOF 3.-' AVr I 7-‘6, I� 1 70 9 4 A - LJ UtLVIVLIIIVIV tCJIUGi�Ii�+� 1�/ LOTH BLOI'.K .(! �� SUB DIVISION PI4U per 1C... � 0 ITION V ❑ CONVERTING USE ❑ COMMERCIAL 7, DESCRIPTK>N OF WORK. !. ALTERATION ❑ ACCESSORY BLDG. 8. FIRE SPRINKLERR i y / y L 1 "t ❑ REPAIR ❑ POOL / SPA ❑ YES MAT ij �% -- 5 — t � � 1 V & / / .;,__ a- ❑ MOVE ❑ OTHER ❑ NO PROPERTY OWNER: CONTRACTOR: ARCHITECT 1 ENGINEER: 9. NAME: 15. COMPANY NAME 23. COMPANY NAME: - _ 4 /4 71') /) /4 I�4 c�/' //✓C 24. LICENSEE NAME: LIK j//1 n 6 , ra.) . : 1 Id AUUKEJ F-� 2'. A ESS. - '-ficic�,,rn/ 0 3 Z2-4 /vv rye 3 s : v a z -,x sit, 3zz z r�..J..1� 11 (1FFI(`F PN(11.IF I13 FAX AI(1' 1 I�FFif F PH(1NF I7n FAX N(1 �7 /IFFI(`. P (INFO 1 �0. FA 1 ^ � a go 1 1 2y2 -4 14'Zi-0‘7i7 »n V V I Q A (..4.1_ rrlu� e 9 �""'� I + � 1 4.6 - ar I 29. CELL P l+ R I g a 14. tIVIAIL AUUr<tJJ. LL. t IHIL HU t W 3U. tIMAIL A tJ Y i! c4 4,,n 5 21 n.0 a)",7 ✓ Al/!'! ✓/ - ,:. .. . • � ¢ FEE SIMPLE TITLE HOLDER: BONDING COMPANY: ' M ` r , l ?!J (IF OTHER THAN OWNER ) . �! ,� v 31 NAME- 33. NAME. 35. NAME: w H rn p 1 32. ADDRESS: 34. ADDRESS: 36. ADDRES � �, , : I L F ® a t I 1 i ' . Application is hereby made to obtain a permit to do the work and installations as indicated. I ce ; th AP O * r I > . 4.8 commenced prior to the issuance of a permit and that all work will be performed to meet the standards of 11 ,Iw r lati o l •tr o�rnry i 8 (7� jurisdiction This permit becomes null and void if work is not commenced within six (6) months. or if trI R�r ` I: s acilri nP abandoned for a period of six (6) months at any time after work is commenced. I understand that s , , List se cured for Electrical Work, Plumbing, Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks, Air Conditione a4.+..b - OWNER'S AFFIDAVIT - I certify that all the foregoing information is accurate and that all work will be done in compliance wil pplicable laws regulating construction and zoning. I will not occupy or use the referenced building or any part therof, until all inspections - °- prior to obtaining a certificate of occupancy or completion issued by the building official, as required by law. * ** WARNING TO OWNER: *** YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR I PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING. CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER or AGENT CONTRACTOR rt n1, Power of Attorney orAgenc etterRequired)' •a Mier Only ', 7 /y A de r �y Date: (--/ - 7 —/ Z Signed: " IC/ G Y ! G... Signed: Ale � L // ,. /// Date: Before me this r Th d•'; o PGUN Ix�MI , -2699 in the county of Before me this d- I NICO> , in the county of Duv State of Florida, h.� personally app d ,�` Z . Duval, State of FI 'da, has personally appeare herin by hims/ herself and affirms that all statements and declarations are herin by himself / herself and affirm t all statements and declarations are true and accurate. / true and accurate. Notary Public at Large, State of County of f Notary Public at Large, State o County of u V Ul� ❑ Personally Known "� J, LL .J _ I / , ❑ Personally Known `-� , - 1 _ 1 - 1 ,Y 8 J� .7 ?' S G- - ' 7 a I.l,Produced Identificatio .. i. , '� *�r•r l�- Produced Identlfla bon - �I �J / MIN Notary Sign. ;,,->' '.;fll� / affi/� / I Notary Signature: ow., a •.,u a • E 1 1'230 r, Bonded Thu Troy Fah Insurance 800.385.7818 •,Y ,.,, ELIZABETH A. RICKERTSEN i., : s Commission # DD 870870 BLDG01 Permit Application Bldg: REVISED: 12/18/2008 • = Expires May 16, 2013 ' ' k; '� Bonded Thru Troy Fain In.nIv0809.385-7019 Doc # 2012015316, OR BK 15830 Page 1520, Number Pages: 1 Recorded 01/24/2012 at 11:38 AM, JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY r, ,,.ii Nu. /c- — C9/0 / RECORDING $10.00 Tax Folio No. �/ NOTICE OF COMMENCEMENT Ctat "n1 in e of _, __ ( of 1, ,�r✓�T'"' The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. /}v e /C.. �� ' 1. Description of property: 989 GY !� G�g € d , z ' 25 2. General description of improvement: 1 owner infnrmatinnm a. N.me and address b. Interest in property • ,/e -re — c. Name and address of fee simple titleholder (if other than Owner): 4. Contractor Pre B Contractor: WCI Group, Inc. 1100 Shetter Ave. Suite 203 Jacksonville Beach, FL 32250 p y. Contractor's phone number (904) 242 -4444 (Fax) 242 -7077 5. Surety a. Name and address: b. Phone number: c. Amount of bond: 5 __— 6. Lender a. Lender Name Et Address: - b. Lender's phone number: - — 7.a. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: _ b. Phone numbers of designated persons: — 8.a. In addition to himself or herself, Owner designates of to receive a copy of the 1 ionnr'c Nntiro nc nrnwirlcri in Cortinn 711 11111011 FInrirla Ctnti itoc b. Phone number of person or entity designated by owner: 9 Fxniration date of notice of commencement (the exniratinn date is 1 year from the date of rernrdino unless a different date is specified) WARNIN(; TO (1WNFR• ANY PAYMENTS MAnF RY TI-1F f1WNFR AFTFR TI-IF FYPIRATIfN OF TI-4F Nf1TICF (1F (•(1MMFNCFAAFNT ARF CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN Yfll IR PAYIN(; TWIf F FOR IMPROVFMFNTS Tfl Y(ll IR PROPFRTY A Nf1TICF f1F COMMFNCFMFNT MI KT RF RFf nPnFn Awn POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN KAteRNEY BEFORE CO ENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. -- � 1 7 - /Z- c:;ratu e .f ^w r (4, — Date bil The foregoing instrument was acknowledged before me this 1 day of 1 Zin the County of Duval, State of Florida. has oersonally aooeared , herein by himself /herself and affirms that all statements and declara erein are true and accurate. Personal K . 6 p n� _ . ..� 'ro• 'ced I entification Type of Identification Produced .7((" , / / " sy , z__—, z i 7/9 hc‘z-/A / i-LepA) nature of Notary Public - State of Florida Print, Type, or Stamp Commissioned Name of Notary Public Verification pursuant to Section 92.525, Florida Statutes. Under penalties o perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and /lief. " xw sip- �rlaLur 0 Niatu al Person Signing Above , ,v = ELIZABETH A.RICKERTSEN g . :* ah .r<_ Commission # DD 870870 .� 1 Expires May 16, 2013 • s „ ' ' i d9nekd SIN troy Fain Immo (4(61131140.12 / y/9 rdiePlan Lap Sidi — Z,...0 . JamesHardie H a rdiePlan k ® EFFECTIVE APRIL 2009 INSTALLATION i7Ef?iJIIiEIi1EPjTS PRIMED tuiul_Oi3PLiIS" PRODUCTS vi ,^r_+ Mara^; hardio .c!in ^: for the most recent version. SELECT CEDARMILL© S BEADED COLON O IA L SM H - EDGE SHINGLE COLONIAL ROUGHSA N ®• BEADED CEDARMILL© IMPORTANT: FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS, INSTALLATION OF HZ1OTrv' PRODUCTS OUTSIDE AN HZ1O LOCATION WILL VOID YOUR WARRANTY TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1- 866 -942 -7343 (866 9HARDIE) STORAGE & HANDLING: © CUTTING INSTRUCTIONS Store flat and keep dry and OUTDOORS INDOORS 1, Position cutting station so that wind sail blow dust away from user 1 :. Cut only using score and snap, or shears (manual, electric or pneumatic). covered prior to installation. Installing and others in working area. 2. Position tutting station in wet- ventilated area siding wet or saturated may result in 2. Use one of the following methods: shrinkage at butt joints. Carry planks a. Best i. Score and snap 9 1 ii. Shears (manual, cicctrc or onoumstid) - NEVER use a power saw indoors an edge. Protect edges and corners b. Better: L Dust reducing circular saw equiyped with a - NEVER use acircular saw blade that does not carry the IiardieBlade saw blade trad Omar; from breakage. James Hardie is not HardieStarle` saw blade and I1EPA vacuum extraction - NEVER dry sweep — Use wet suppression or IIEPA Vacuum L. Good: i. Dust reducing circular saw with a i IardieSlade saw blade responsible for _ (only use for law to moderate cutting) damage caused 1i "? ay g" 9 `� �, I Important Note: F or max pro Rawest respir dust production), James Hardie recommends always using Hest " -level cutting methods Mere feasible. by improper '� I NIOSII- approved mentors can be used in coiuunction with above flitting practices to further reduce dust exposures. Additional exposure information is available storage and \ I� at vwrw.jamesha��die.com to help you determine the mast appropriate cutting method for your it requirements. If ca cam still exists about exposure levels or YOU handling of the product. do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie :tor turt :er information. Team GENERAL REQUIREMENTS: • HardiePlank" lap siding can be installed over braced wood or steel studs spaced a maximum of 24" o.c. or directly to minimum 7/16" thick OSB sheathing. Irregularities in framing and sheathing can mirror through the finished application. • HardiePlank lap siding can also be installed over foam insulation /sheathing up to 1" thick. When using foam insulation /sheathing, avoid over - driving nails (fasteners), which can result in dimpling of the siding due to the compressible nature of the foam insulation /sheathing. Extra caution is necessary if power- driven nails (fasteners) are used for attaching siding over foam insulation /sheathing. • A water- resistive barrier is required in accordance with local building code requirements. The water- resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie wit assume no responsibility for water intiltration. James Hardie does manufacture HardieWrap' Weather Barrier, a non -woven non - perforated housewrapl , which complies with building code requirements. • When installing James Hardie products all clearance details in figs. 3,4,5,6,7,8, &9 must he followed. • Adjacent finished grade must slope away from the building in accordance with local building Figure 1 Double Wall Single Wall codes - typically a minimum of 6" in the first 10'. Construction Construction • Do not install James Hardie products, such that they may remain in contact with standing water. water - resistive barrier let -in bracing • HardiePlank lap siding may be installed on flat vertical wall applications only. plywood or 24" o.c. max. • DO NOT use stain on James Hardie products. OSB sheathing ;f INSTALLATION: 1 JOINT TREATMENT` //pi (Required for Co/orPluse' Finish, Recommended for Primed product) % / James Hardie does not recommend the use of caulk at field butt joints. Figure 2 water - resistive stud \� I , barrier W ..-- - \ �� 1 an " f plp �^ "� joint Flashing° r L— 18 from j � • • % � > , • / j e cu e, install s in I moderate to contact " 1 Il °�\ / water-resistive i nom \ � .. barrier I - '''• fastener fastener Install a 1 114" starter strip to Install factory finished edges together at butt joints. ° moo o .-0 ensure a consistent plank angle For other jointing options, refer to local building code or NER 405 \ e " "As required by local building code ' "'Apply caulk in accordance with caulk manufacturers written application instructions. leave a ppr p between ' For additional information on HardieWrap Weather Barrier, consult James Hardie at 1- 866- 4Hardie or www.hardiewrap.com WARNING: AVOID BREATHING SILICA DUST James Hardie° products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. Some studies suggest smoking may increase these risks. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for cutting or, where not feasible, use a Hardieelade saw blade and dust - reducing circular saw attached to a HEPA vacuum; (3) wam others in the immediate area; (4) wear a properly - fitted, NIOSH- approved dust mask or respirator (e g. N -95) in accordance with applicable government regulations and manufacturer instructions to further limit respirable silica exposures. During clean -up, use HEPA vacuums or wet cleanup methods - never dry sweep. For further information, r refer 0 AND installation instructions INSTRUCTIONS and Material I o ty Data TO SeeRIOail PERSONAL at t cow L nashar OR DEATHby calling 1- 800- 9HARDIE (1- 800 -942- 7343). FAILURE TO ADHERE TO OUR WARNINGS, Hs0920-P114 4/09 y to At the juncture of the roof and vertical CLEARANCES Maintain a 1" - 2" clearance between surfaces, flashing and countertlashing shall Install siding and trim products in compliance James Hardie products and decking be installed per the roofing manufacturer's with local building code requirements for Maintain a 1" - 2" clearance material. instructions. Provide a 1" - 2" clearance clearance between the bottom edge of the between James Hardie` Fi r ure 5 between the roofing and the bottom edge of siding and the adjacent finished grade. products and paths, steps and driveways. ' the siding and trim. siding water a Figure 3 stud y rbarrie Fi r ure 6 water resistive - 1" - Y barrier ' barrier w Figure 4 deck material I', I I : i � 1 ,_ 2 , gir foundation / I ' . ` joist I 1 aching � . , ledger ��i� 1 flashing '\'''' HardiePlank® I Figure 9 \" min. lap siding 1 \ KICKOUT FLASHING Maintain a 1/4" clearance Maintain a minimum 1" gap " s " ' t - Because of the volume of water that can pour down between the bottom of James between gutter end caps and nape ,,� �- a sloped root, one of the most critical flashing ;° Hardie products and horizontal siding &trim. -I �- 1 details occurs where a roof intersects a sidewall. 1np flashing. Do not caulk gap. Figure 8 ` ✓� °4 sow wlhed as. The roof must be flashed with step flashing. Where gig the roof terminates, install a kickout to deflect water nasnm Figure 7 ° Dn edge away from the siding. , siding g v It is best to install a self - adhering membrane on the ''I 00 not 114 50P siding . wall before the subfascia and trim boards are nailed h— Caulk j ng `' o,. rPwrap I in place, and then come back to install the kickout. + � fasc Figure 9, Kickout Flashing$ To prevent water from dumping behind the siding and the flashing .. 4I end of the roof intersection, install a "kickout" of sufficient length and angle to direct the ° gutter and end cap water running down the roof away from the siding. FASTENER REQUIREMENTS ** Blind Nailing is the preferred method of installation for all Face Nailing should only be used where required for high wind areas HardiePlank lap siding products and must not be used in conjunction with Blind Nailing BLIND NAILING FACE NAILING Nails - Wood Framing Nails - Wood Framing • Siding nail (0.09" shank x 0.221" HD x 2" long) • 6d (0.11 3" shank x 0.267" HD x 2" long) • 11 ga. roofing nail (0.121" shank x 0.371" HD x 1.25" long) • Siding nail (0.09" shank x 0.221" HD x 2" long) Screws - Steel Framing Screws - Steel Framing • Ribbed Wafer -head or equivalent (No. 8 x 1 1/4" Tong • Ribbed Bugle -head or equivalent (No. 8 -18 x 1 -5/8" long x x 0.375" HD) Screws must penetrate 3 threads into metal framing. 0,323" HD) Screws must penetrate 3 threads into metal framing. Nails - Steel Framing Nails - Steel Framing • ET & 6 Paneltasttl nails or equivalent • ET & F pin or equivalent (0.10" shank x 0.25" HD x 1-1/2" long) (0.10" shank x 0.313" HD x 1-1/2" long) Nails must penetrate minimum 1/4" into metal framing. Nails must penetrate minimum 1/4" into metal framing. OSB minimum 7/16" OSB minimum 7116" • Siding nail (0.09" shank x 0.221" HD x 1 -1/2" long)' • llga. roofing nail (0.121" shank x 0.371" HD x 1.75" long) 24„ _--------► • Ribbed Wafer-head or equivalent (No. 8 x 1 5/8" long x 0.375" HD). stud O. C. max. 24"_ - - - - ' I Figure 10 Figure 11 1 1 v4" min stud — ) overlap O.0 max �'j, -, _ _ water resistive , - , Minimum overlap / _ -I _ barrier - o \ for Both Fact: I o ; I and Blind Nailing I I I blind nail �� a /4 „_1„ t 1 ) \ min. 11/4' I� 1 I I -1— facenail . I o overlap l I , r 11 f 1 = _ — t' I i wa res water- resistive - ✓ yJr barrier 114” mm' barrier L_________.-/ overlap Laminate sheet to be removed immediately after installation of each course for ColorPlus products. $ The Illustration (figure 9) and associated text was reprinted with permission of THE JOURNAL OF LIGHT CONSTRUCTION. For subscription information, visit www.jlconline.com. * When face nailing to OSB, planks must he no greater than 9 1/4" wide and fasteners must be 12" o.c. or less. "Also see General Fastening Requirements. HS0920 -P2/4 4/09