141 OCEAN GATE DR - REV .ENERGY SHEETS FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-QUADPLEX-OUTSIDE-A2 Builder Name: BEACHES HABITAT Street: 141 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Jurisdiction: 4451311t) 2,61.■0 0 Owner: Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(1637.3 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 1138.70 ft2 2. Single family or multiple family Multi-family b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (605.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 605.00 ft2 N/A R= ft2 6. Conditioned floor area above grade(ft2) 1170 b. R= ft2 c.N/A Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(130.0 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165 a. U-Factor: Dbl,U=0.30 130.00 ft2 SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency a.Central Unit b. U Factor: N/A ft' 22.7 SEER:15.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a. Electric Heat Pump 23.6 HSPF.8.50 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. 14.Hot water systems Area Weighted Average SHGC: 0.300 a. Electric Cap:40 gallons 8. Floor Types (605.0 sqft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 27.52 PASS Glass/Floor Area: 0.111 Total Baseline Loads: 31.69 _.. .-..-...•. I hereby certify that the plans and specifications covered by Review of the plans and .,0•o4 C8E STgr�•'s• this calculation are in compliance with the Florida Energy specifications covered by this v , .q'' "'A Code. calculation indicates compliance r co %qv.''• e ,e : with the Florida Energy Code. ' ���,.� . '""'` `"•" O 1. PREPARED BY: J FERNANDEZ(ESIGN) Before construction is completed DATE: 10/2015 this building will be inspected for 0 p„ compliance with Section 553.908 -. attio 0 Florida Statutes. 'r I hereby certify that this building, as designed, is in compliance +.•`•f' 1LJc�+'+ Y Y Opw T '• with the Florida Energy Code. +`'' .+.,..,,•+•"'' ':-. 1 OWNER/AGENT: ',� L' - BUILDING OFFICIAL:,t����' DATE: -_- - /1- `� -/ )' DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 00444 )61.. 10/30/2015 2:39 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: HABITAT-QUADPLEX-OUTSI Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1170 Lot# Owner: Total Stones: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 270 Street: 141 OCEAN GATE DRI Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 1170 9360 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 565 4520 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 605 4840 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 605 ft2 ___ 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 638 ft' 100 ft2 Medium 0.85 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 605 ft' N N CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 605 ft' 0 Wood 10/30/2015 2:39 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt TO wall Type Space R-Value Ft In Ft In Area R-Values Frartion Ahsgr Grade% 1 N=>W Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 2 E=>N Exterior Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 3 S=>E Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 4 W=>S Neighbor Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 5 N=>W Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 6 E=>N Exterior Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 7 S=>E Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 8 W=>S Neighbor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated 1st Floor Metal .46 3 6 8 20 ft2 2 S=>E Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 6 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 7 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed CFM(50) .1 .00 .01 .0000 .0003 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 23.55 kBtu/hr 1 sys#1 10/30/2015 2:39 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 Milk FORM R405-2014 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 22.71 kBtu/hr 681 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF ft2 None None DUCTS —Supply— --Return-- Air CFM 25 CFM25 HVAC#- # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling X Jan 'X Feb X Mar X Apr X May p)<(1 Jun -X Jul X Aug X Sep X Oct X Nov X Dec Jun 'X Jul Aug X Sep X Oct X Nov X Dec Ventig ff X Jan X1 Feb �Xi Mar IXI Apr �Xi May X Jun X�Jul [Xi Aug Xi Sep tX1 Oct tX1 Nov X Dec Venting l Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 AM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WD) PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) PM 72 72 72 72 72 72 72 72 72 72 72 72 0 10/30/2015 2:39 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index,the more efficient the home. 141 OCEAN GATE DRIVE, ATLANTIC BEACH , FL, 32233 From Plans) 9. Wall Types Insulation Area 1. New construction or existing New(From a.Frame-Wood,Exterior R=19.0 1138.70 ft2 2. Single family or multiple family Multi-family b.Frame-Wood,Common R=19.0 498.67 ft2 R= ft2 3. Number of units,if multiple family 1 c.N/A d.N/A R= ft 2 4. Number of Bedrooms 3 Insulation Area 10.Ceiling Types 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 605.00 ft2 b.N/A R= ft2 6. Conditioned floor area(ft2) 1170 c N/A R= ft2 7. Windows** Description Area 11.Ducts R ft2 a. U-Factor. Dbl,U=0.30 130.00 ft2 a.Sup:1st Floor,Ret: 1st Floor,AH:Attic 6 165 SHGC: SHGC=0.30 ft2 SHGC:b. Factor: N/A 12.Cooling systems kBtu/hr Efficiency S ft2 a.Central Unit 22.7 SEER:15.00 c. U-Factor: N/A SHGC: ft2 kBtu/hr Efficiency d. U-Factor: N/A 13.Heating systems SHGC: a.Electric Heat Pump 23.6 HSPF:8.50 Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 Insulation Area 14.Hot water systems Cap:40 gallons 8. Floor Types a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 a.Electric EF:0.92 b.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building OSt1ti sT,,T�•., Construction through the above energy saving features which will be installed (or exceeded) ti per..: in this home before final inspection. Otherwise,a new EPL Display Card will be completed ;4 _• ; based on installed Code compliant features. • I;i a Builder Signature: /'_Al"-T7 Date: /1 L/' /1 `, � •/ O� • ✓ �r Address of New Home: pit ("64, t_ City/FL Zip: . . 4...c, / ... *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. 10/30/2015 2:40 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Florida Code 2014 Summary Report Title: HABITAT-QUADPLEX-OUTSIDE-A2 TMY City: FL JACKSONVILLE_ 141 OCEAN GATE DRIVE FLProp2014 Elec Util: Florida Average ATLANTIC BEACH , FL, 32233 Gas Util: Florida Average Registration #: Run Date: Energy Uses Reference Home Proposed Home e-Ratio Heating 2.43 MBtu 1.37 MBtu 0.56 Cooling 5.66 MBtu 4.95 MBtu 0.87 Hot Water 8.58 MBtu 8.94 MBtu 1.04 Total 16.67 MBtu 15.26 MBtu 0.92 Building Loads Reference Home Proposed Home e-Ratio Heating 5.13 MBtu 2.89 MBtu* 0.56 Cooling 18.15 MBtu 15.87 MBtu* 0.87 Hot Water 8.41 MBtu 8.76 MBtu* 1.04 Total 31.69 MBtu 27.52 MBtu 0.87 normalized modified loads Glass/Floor Area: 0.111 Total Proposed Modified Loads: 27.52 PASS Total Reference Loads: 31.69 10/30/2015 2:40 PM EnergyGauge®USA-FlaRes2014/ Page 1 of 1 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-QUADPLEX-OUTSIDE-A2 Builder Name: BEACHES HABITAT Street: 141 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/30/2015 2:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 141 OCEAN GATE DRIVE Permit Number: I ATLANTIC BEACH .FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. %l 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ti R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. 0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official.an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors.fireplace and stove doors shall be closed,but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust.intake, makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures: 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed: 5.Heating and cooling systems,if installed at the time of the test,shall be turned off:and 6.Supply and return registers.if installed at the time of the test,shall be fully open. c R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. c R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2).when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. c R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. i R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. K] R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. XI R403.2.2 Sealing(Mandatory)all ducts,air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes.or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C)shall be insulated to a minimum of R-3., C R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight.moisture.equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ accessible ssible Circulating switch that systems(Mandatory). Circulating hot water systems off the hot-water circulating pump when the system is not in use. with an automatic or readily ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'h inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. gi R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies C R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls • capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100`F to 140°F(38°C to 60°C). R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied • to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. c R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation.Commercial Provisions.for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy • factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the ❑ Florida Building Code,Residential or Florida Building Code, Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. C R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. � R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical , ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3 If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. K1 R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. G R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. Page 2 of 3 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal. rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data. the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer, in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. C R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ▪ R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. C R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. • R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F. ❑ R403.9 Swimming pools, inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. C R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas- and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. C R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. c: R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. o R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 Job: QUADPLEX-OUTSIDE UNI... Manual S Compliance Report Date: 1012015 +�+ wrightsoft at Entire House JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:NMNV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 141 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions gain: Btuh Entering coil DB: 76.2°F Sensible ain: 17 Outdoor design DB: 92.0°F Outdoor design WB: 78.0°F Latent gain: 2425 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 20356 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A"30+FX4DNF025 Actual airflow: 800 cfm Sensible capacity: 21971 Btuh 123%of load Latent capacity: 744 Btuh 31%of load Total capacity: 22715 Btuh 112%of load SHR: 97% Heating Equipment Design Conditions Outdoor design DB: 39.0°F Heat loss: 21480 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A**30+FX4DNF025 Actual airflow: 800 cfm Capacity balance: 36 °F Output capacity: 23554 Btuh 11CP/o of load Capaomic balance: 36 °F Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 5.2 kW 83%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Oct-30 14:41:17 wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 ACM ..htsoft HVACIHABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.ruP Calc=MJ8 Building Front faces: W 1, Residential Plans Examiner Review Form Form ACCar for HVAC System Design (Loads. Equipment. Ducts) RPER 1 15Mar09 At(irrlrrq Grtatn,ryMwra Header Information Contractor: FLORIDA AIR SERVICE&ENGINEERING REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ® No ❑ Mechanical license: CAC1813923 or MJ1AE Form*(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes ❑ No ❑ Building plan#: Manual D Friction Rate Worksheet: Yes [7l] No ❑ Duct distribution sketch: Yes ® No ❑ Home address(Street or Lot#,Block,Subdivision): 141 OCEAN GATE DR, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 39 °F Orientation: Building Front faces West North,East,West,South,Northeast,Northwest,Southeast,Southwest Indoor temperature: 70 °F Total heat loss: 21480 Btuh Number of bedrooms: 3 Conditioned floor area: 1170 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 92 °F Indoor temperature: 75 °F Windows Rod Grains difference: 58 gr/Ib @50%RH Eave overhang depth: 8.0 ft Sensible heat gain: 17931 Btuh Internal shade: none Eave Latent heat gain: 2425 Btuh Blinds,drapes,etc. Depth Window Total heat gain: 20356 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Fquipment Data Cooling Fquipment Data Blower Data Eau ment type: Split ASHP Eauioment t i e: Split ASHP Heating cfm: 800 u e Hea hump,Boiler,etc. Ir ondflb Heat pump,etc. Cooling cfm: 800 Model: Carrier Model: Carrier Static pressure: 0.50 in H2O 25HBC524A`"30+FX4DNF025 25HBC524A"30+FX4DNF025 Fan's rated external static pressure for design airflow Heating output capacity: �3�54 Btuh Total cooling capacity: 22715 Btuh Heat pumps-capacity at winter design ou oo conditions Sensible cooling capacity: 21971 Btuh Aux.heating output capacity: 17762 Btuh Latent cooling capacity: 744 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 800 cfm Longest supply duct: 377 ft Duct Materials Used Equipment design ESP: 0.50 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 377 ft Available static pressure(ASP): 0.50 in H2O Friction rate: 0(� p in/100ft Branch duct: Round flex vinyl Friction Rates ASP+(TELYl I declare the load calculation,equipment equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification Contractor's printed name: J FERNADNEZ Contractor's signature: J FERNANDEZ(ESIGN) Date: 10/2015 Reserved for County. Town Municipality or Authority having jurisdiction use. 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist ' wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 +y+ wrightsoft Load Short Form Job: QUADPLEX-OUTSIDE UNI... Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEI ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 141 OCEAN GATE DR, ATLANTIC BEACH, FL 32233 Design Information Htg Clg Infiltration Outside db(°F) 39 92 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 31 17 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 40 50 Moisture difference(grub) 16 58 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC524A**30 Cond 25HBC524A**30 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17718 Btuh Heating output 23554 Btuh @ 47°F Latent cooling 4997 Btuh Temperature rise 27 °F Total cooling 22715 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) BATH2 96 794 426 30 19 MBED 196 10337 9111 385 406 BED2 158 2062 1253 77 56 GREAT 249 3160 4301 118 192 MWIC 32 490 94 18 4 BATH1 52 100 130 4 6 M EC H 48 501 126 19 6 BED3 151 1996 1204 74 54 KITCHEN 188 2039 1286 76 57 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +`+ wrightsoft 2015-Oct-30 14:41:18 t ' g Right-Suite® 2015 15.0.17 RSU13554 Page 1 AE ...htsoft HVACIHABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces: W Entire House 1170 21480 17931 800 800 Other equip loads 0 0 Equip. @ 1.00 RSM 17931 Latent cooling 2425 TOTALS 1 1170 I 21480 I 20356 I 800 I 800 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AL-. wrl htsoft' 2015-Oct-30,a:a,:,s . 9 Right-Suite® RSU13554 Paget ...htsoft HVACWABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces: W Building Analysis Job: QUADPLEX-OUTSIDE UNI... Date: 10/2015 +++ wrightsoft Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email.FAE @ENGINEER.COM Web.WWW.NORTHFLORIDAAIR.COM Pro'ect Information For 141 GATE AOCEAN GIDR, ATLANTIC BEACH, FL HABITAT 33233 Desi• n Conditions Indoor: Heating Cooling Location: Indoor temperature (°F) 70 75 Elevation: May16rt Naval, FL, US Design TD (°F) 31 17 L titude: 16 ft Relative humidity (%) 40 50 Latitude: 30°N Moisture difference(gr/Ib) 15.7 58.2 Outdoor: Heating Cooling Dry bulb(°F) 39 92 ( I ) Infiltration: Simplified Daily ran(0 ) 78 Construction quality Average- W V\iet ind d speee d (mph)bulb F) 15.0 7.5 Fireplaces 1 (Average) W Component Btu h/ft2 Btuh %of load – Walls 2.0 1262 5.9 Glazing 48.2 11660 54.3 Doors 0 0 0 Ceilings 1.0 1161 5.4 Floors 1.2 1431 6.7 Infiltration 3.8 3373 15.7 ,.,..,L :.. ..,..... Ducts 2593 12.1 Piping 0 0 0 0 Humidification 0 0 Ventilation 0 Adjustments Total 21480 100.0 Coolin• Component Btu h/ft2 Btuh %of load -1 Walls / Glazing 46.6 11289 63.0 ` = ` 0 0 0 Doors ��,y,.,, Ceilings 1.7 2035 11.3 Floors 0 0 0 Infiltration 0.8 754 4.2 — . . Ducts 3086 17.2 ---- Ventilation 0 0 Internal gains 0 0 zr Blower 0 0 Adjustments 0 Total 17931 100.0 Latent Cooling Load=2425 Btuh Overall U-value=0.155 Btuh/ft2-°F Data entries checked. 2015-Oct-30 14 41:18 Page 1 ' " wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 ACCh .htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces: W Project Summary Job: QUADPLEX-OUTSIDE UNI... +I+ wrightsoft Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:VWWV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT -A, BEACHES HABITAT 141 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Notes: Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 58 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18887 Btuh Structure 14845 Btuh Ducts 2593 Btuh Ducts 3086 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21480 Btuh Use manufacturer's data Y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17931 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1596 Btuh Ducts 829 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1170 1170 Equipment latent load 2425 Btuh Volume (ft') 10530 10530 20356 Btuh Air changes/hour 0.56 0.23 Equipment total load Equiv. AVF (cfm) 99 40 Req. total capacity at 0.78 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC524A"30 Cond 25HBC524A**30 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17718 Btuh Heating output 23554 Btuh @ 47°F Latent cooling 4997 Btuh Temperature rise 27 °F Total cooling 22715 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Oct-30 14:41:18 -Fi+ wrightsoft Right-Suite®U niversal 2015 15.0.17 RSU13554 Page 1 AC ..htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces. W 41- Job: QUADPLEX-OUTSIDE UNI...wrightsoft Loads for Multiple Orientations Date: 1012015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE@ENGINEER.COM Web:W N.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT -A, BEACHES HABITAT 141 OCEAN GATE DR, ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) V tt bu lb(°F) - 78 Wind speed (mph) 15.0 7.5 Building Front North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 19163 17105 19695 21522 22224 20052 17931 19836 Latent Load (Btuh) 2425 2425 2425 2425 2425 2425 2425 2425 Total Load (Btuh) 21588 19530 22120 23947 24649 22477 20356 22261 Heating AVF (cfm) 800 800 800 800 800 800 800 800 Cooling AVF (cfm) 800 800 800 800 800 800 800 800 Building Orientation Cooling Load .1111 iim 0 I • S 9,N W 1'W N � Dredion BJldrg Frcrtfaoes Current Orientation: Building Front faces West Highest Cooling Load: Building Front faces South Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Oct-30 14:41:18 ' wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 A ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces: W Job: QUADPLEX-OUTSIDE UNI... +i+ wrightsoft Duct System Summary Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE.FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER COM Web.wMNJ.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 141 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.500 in/100ft 0.500 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 377 ft Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk MECH h 542 28 10 0.500 4.0 Ox 0 VIFx 307.0 70.0 BATH2 h 818 42 30 0.500 4.0 Ox 0 VIFx 307.0 70.0 MBED h 3382 172 147 0.500 7.0 Ox 0 VIFx 307.0 70.0 BED3 h 2297 117 96 0.500 6.0 Ox 0 VIFx 307.0 70.0 KITCHEN h 2343 119 103 0.500 6.0 Ox 0 VIFx 307.0 70.0 BED2 h 2366 120 100 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT c 2148 85 148 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT-A c 2148 85 148 0.500 6.0 Ox 0 VIFx 307.0 70.0 BATH1 c 148 6 10 0.500 4.0 Ox 0 VIFx 307.0 70.0 Mwnc h 530 27 7 0.500 4.0 Ox 0 VIFx 307.0 70.0 2015-Oct-30 14:43:54 1 A wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 A ..ghtsoft HVACtHABIJAX-QUAD-OUTSIDE UNIT-A-MD.rup Calc=MJ8 Building Front faces W