399 BEACH AVE - HVAC 1_,J-.1`11(�
- '' CITY OF ATLANTIC BEACH
s J 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 15-MECH-2739
Job Type: MECHANICAL HVAC ONLY
Description: HVAC - 1 AC, 1 AHU, 4 TON
Estimated Value: $4,000.00
Issue Date: 11/23/2015
Expiration Date: 5/21/2016
PROPERTY ADDRESS:
Address: 399 BEACH AVE
RE Number: 170187-0000
PROPERTY OWNER:
Name: GOELZ, THOMAS AND DONNALEA, *
Address: 399 BEACH AVE
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING & AIR
Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN
Phone: 904-241-3785
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $24.00
AC and Refrigeration $32.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $115.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845 f, 5 -• ' EC,(_ Z73s
lOB ADDRESS: 39(7 ae.O,G1k I't V C PERMIT#
PROJECT VALUE $ 9 3a ARI# --- y 0197 6 REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity 1 Tons Per Unit _-
Heat: Unit Quantity BTU's Per Unit , �'� Seer Rating ia,() .
Duct Systems: Total CFM REQUIRED
2EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
■IRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
■IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
LLL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
'roperty Owners Name To 613-(:12 Phone Number Cp) (0 3 260
Mechanical Company 1 �\1pn \t\to,'t 0- ,2, c Office Phoney 1 "37 '5Fax
:o. Address: --7.- 1 5 l \\ sOU-V.-N City oa ri- c..O.(,\-, Stated Zip 3c%-, ).
.icense Holder(Print): \,J.)\-\\, "1-- .o�ov a State Certification/Registration #Co.(.O 3110 I
notarized Signature of License Holder \4\, ,c----- I)f-------
_;ti reik RICHARD TOMPKINS
Before me this 013 day of NQ\I 20 1
_* i s :._ Commission#FF 040399
=g'—:,,,.a= Expires July 29,2017 Signature of Notary Public Sr
e;`.°•'' Bonded Thru Troy Fsn Insurance B00-385-70t9
Project Summary Job:
Entire House
Date: November 19,2015
By:
Donovan Heat & Air
315 i3th Avo S,Jacksonville BeA6h,FL 32250 Phone:904.241-3785 FAx:PO4.241-3745 Email:aeron®tlonovenac,com Web www.donovenae.com
.. •Pro'ect Information.
For: Tom Goelz
399 Beach Ave, Atlantic Beach, FL 32233
Notes:
Desi• n Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 99 °F
Inside db 70 °F Inside db 75 'F
Design TO 31 °F Design TD 24 °F
Daily range L
Relative humidity 55 %
Moisture difference 62 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24583 Btuh Structure 23407 Btuh
Ducts 5218 Btuh Ducts 7756 Btuh
Central vent(62 cfm) 2101 Btuh Central vent(62 cfm) 1627 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping load 31902 Btuh Use manufacturer's data n
Rate/swing multiplier 1.04
Infiltration Equipment sensible load 34102 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 3361 Btuh
Ducts 2051 Btuh
Heating Cooling Central vent(62 cfm) 2617 Btuh
Area (ft2) 2263 2263 Equipment latent load 8029 Btuh
Volume (ft') 22630 22630
Air changes/hour 0,37 0.16 Equipment total load 42130 Btuh
Equiv.AVF (cfm) 141 60 Req. total capacity at 0.70 SHR 4.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make T- r Make T p�,ps.tar j 5-
Model Trade
ARI ref no. Cond bra'
Coif
Efficiency ARI ref no. —111916—
Y 0 COP Efficiency 0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 1319 cfm Actual air flow 1319 cfm
Air flow factor 0.044 cfm/Btuh Air flow factor 0.042 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0,80
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
4,1. •44- wrighresiuf t. Right-Suito5 UniverPel 7.1.01 RSU05995 2015-Nov-20 1715:18
ACCA C:IDocumnnts and Snttinge\OpMan\My Doeuments\Wrightsotl HVAC\TempIAle1Boaus 4 Ton.rup CAic.MJ8 Page 1