Loading...
399 BEACH AVE - HVAC 1_,J-.1`11(� - '' CITY OF ATLANTIC BEACH s J 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-2739 Job Type: MECHANICAL HVAC ONLY Description: HVAC - 1 AC, 1 AHU, 4 TON Estimated Value: $4,000.00 Issue Date: 11/23/2015 Expiration Date: 5/21/2016 PROPERTY ADDRESS: Address: 399 BEACH AVE RE Number: 170187-0000 PROPERTY OWNER: Name: GOELZ, THOMAS AND DONNALEA, * Address: 399 BEACH AVE GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN Phone: 904-241-3785 PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $32.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $115.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 f, 5 -• ' EC,(_ Z73s lOB ADDRESS: 39(7 ae.O,G1k I't V C PERMIT# PROJECT VALUE $ 9 3a ARI# --- y 0197 6 REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit _- Heat: Unit Quantity BTU's Per Unit , �'� Seer Rating ia,() . Duct Systems: Total CFM REQUIRED 2EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ■IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) ■IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators LLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name To 613-(:12 Phone Number Cp) (0 3 260 Mechanical Company 1 �\1pn \t\to,'t 0- ,2, c Office Phoney 1 "37 '5Fax :o. Address: --7.- 1 5 l \\ sOU-V.-N City oa ri- c..O.(,\-, Stated Zip 3c%-, ). .icense Holder(Print): \,J.)\-\\, "1-- .o�ov a State Certification/Registration #Co.(.O 3110 I notarized Signature of License Holder \4\, ,c----- I)f------- _;ti reik RICHARD TOMPKINS Before me this 013 day of NQ\I 20 1 _* i s :._ Commission#FF 040399 =g'—:,,,.a= Expires July 29,2017 Signature of Notary Public Sr e;`.°•'' Bonded Thru Troy Fsn Insurance B00-385-70t9 Project Summary Job: Entire House Date: November 19,2015 By: Donovan Heat & Air 315 i3th Avo S,Jacksonville BeA6h,FL 32250 Phone:904.241-3785 FAx:PO4.241-3745 Email:aeron®tlonovenac,com Web www.donovenae.com .. •Pro'ect Information. For: Tom Goelz 399 Beach Ave, Atlantic Beach, FL 32233 Notes: Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 99 °F Inside db 70 °F Inside db 75 'F Design TO 31 °F Design TD 24 °F Daily range L Relative humidity 55 % Moisture difference 62 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 24583 Btuh Structure 23407 Btuh Ducts 5218 Btuh Ducts 7756 Btuh Central vent(62 cfm) 2101 Btuh Central vent(62 cfm) 1627 Btuh Humidification 0 Btuh Blower 0 Btuh Piping load 31902 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 34102 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 3361 Btuh Ducts 2051 Btuh Heating Cooling Central vent(62 cfm) 2617 Btuh Area (ft2) 2263 2263 Equipment latent load 8029 Btuh Volume (ft') 22630 22630 Air changes/hour 0,37 0.16 Equipment total load 42130 Btuh Equiv.AVF (cfm) 141 60 Req. total capacity at 0.70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make T- r Make T p�,ps.tar j 5- Model Trade ARI ref no. Cond bra' Coif Efficiency ARI ref no. —111916— Y 0 COP Efficiency 0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1319 cfm Actual air flow 1319 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0,80 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 4,1. •44- wrighresiuf t. Right-Suito5 UniverPel 7.1.01 RSU05995 2015-Nov-20 1715:18 ACCA C:IDocumnnts and Snttinge\OpMan\My Doeuments\Wrightsotl HVAC\TempIAle1Boaus 4 Ton.rup CAic.MJ8 Page 1