Loading...
574 TIMBER BRIDGE LN - NEW HOME PERMIT (2) • , R.O.W. Permit Attachment of for R.O.W. Permit# issued ,2015 Atlantic Beach, FL 32233 Owner's Name: Toll FL VI, LP Property Address: 574 Timber Bridge Lane Atlantic Beach, FL 32233 Subdivision: Atlantic Beach Country Club Lot#/Block#: 174 R.E. #: 169505-2130 REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT, issued on this a day of Obi0Zie ,20 /,K,by Atlantic Beach, Florida, a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as "CITY"and Toll FL VI, LP of Atlantic Beach, Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above (copies attached). This work is generally described as: Pavers in the Right of Way for the driveway. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty (30) days notice by CITY to the USER, said notice to USER shall be given by certified mail,return receipt requested,to the following address: 160 Cape May Ave. Ponte Vedra,FL 32081. The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating,replacing, or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code, and all other land use and code requirements of the CITY,including City Code Section 19-7 (h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH R 1 r411 I^ r Y 800 Seminole Road,Atlantic Beach, FL 32233 iI lira 6. 1 id Office(904)247-5826 Fax (904) 247-5845 . Job Address: 574 Timber Bridge Lane;Atlantic Beach, FL 32233 Permit Number:/5'SFR-,2y70 Legal Description Lot 174 Atlantic Beach Country Club Unit 2 Parcel 67-132-08-2S-29E Floor Area of Sqq.Ft. S Ft Valuation of Work$ 335,421 Proposed Work heated/cooled 2.936 non-heatedlcooled 440 Class of Work(circle one): 4110 Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/pro osed structures)((circle one):_ Commercial esidentiall If an existing struc ure,is a fire sprinkler system installed? (Circle one): o N/A Florida Product Approval# See attached • For multiple products use prod%ct approval form Describe in detail the type of work to be performed:New Residential Construction Property Owner Information: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904 217-0739 E-Mail or Fax#(Optional)arogers @tollbrothers.com Contractor Information: CONTRACTOR EMAIL ADDRESS: arogers(i1 tollbrothers.com Company Name: Toll Bros.. Inc. Qualifying Agent: Steven R. Merten Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904 217-0739 Job Site/Contact Number 904 386-6472 Fax# State Certification/Registration# CGC 1510225 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and • Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void([work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6)months at any lime after work is commenced. /understand that separate permits must be secured for Electrical Work, Plumbing, Signs, Wells,Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certifi,that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state,or local law regulating construction or the performance of construction. Signature of Owner �' Signature of Contractor Print Name Steven R. Me en, Division Sr.Vice President Print Name Steven R. Merten Before me Before me • this 12th Ps f October .2015 this 7 Day of October ,2015 A Notary , .A Nota iiric ;:o'.."",`°�•; MELISSA LIEBERMAN Revised 01.26.10 `t "I MY COMMISSION;�FF055605 =:!?e, , EXPIRES September 18.2017 " MELISSA LIEBERMAN (307)3S6 0153 Floridallotarysorvice.com P it .° ;` At 1.11'COMMISSION#FF055605 '.:,.lc` F;' EXPIRES September 18.2017 .,OF F-.. (407139t1-0153 FlorldallotarySorvice.com •• •h' i- • The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall, at the discretion of the CITY, be requested to submit as-built drawings showing the change within thirty(30)days after the day of completion. This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. DATED and SIGNED this 12th day of October , 2015. By: Steve erte , oll FL VI, LP. (to be signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL On this 16t day of October , 2015,personally appeared before me, a Notary Public in and for said County and State, St. Johns, Florida , the property owner of 574 Timber Bridge Lane, Atlantic Beach, Florida, known to me to be the person(s) described in and who executed the foregoing instrument; who acknowledged to me that he or she executed the same freely and voluntarily and for the uses and p y+os'es therein mentioned. 141-1 o�p""°"B‹;'. MELISSA LIEBERMAN • � MY COMMISS1pN�FF055o05 Not P B in for said County and State 4, .�p,> EXPIRES September 18 2017 (407)3060753 FloridalloteryServico.com CITY S F ATLANTIC BEACH,FLORIDA, a municipal corporation: Approv-': / (Do �' ayton,Pu is Works Director For Permits where city sidewalk is impacted, City Manager approval required: Nelson Van Liere, City Manager Page2of2 TFin.61/` 11141re 41W 40L _ Zt'o ,GC0 V00 Atte «Ρ t N X/�3 /f2 2.1 (4 . - _,130 )(3 z go '11IA r PO- -?2 to l ';r14 _it( f ll 360c 6.04 '/`Gk, w`VS k ? �l - z( x 61, Liz.," Mgwo J6 x X70 /ti4A t l.f fr G ( ;3X3 ? „#kr U' r' �`s CITY OF ATLANTIC BEACH c-1 BLI JTILIT 1200 Sandpiper Lane \ ATLANTIC BEACH,FL 32233 (904) 270-2535 or (904) 247-5874 NEW WATER/SEWER TAP REQUEST Date: /0 —20 - /5— Project Address: 57`7/L3 //f-C 640VE No. of Units: Commercial Residential V Multi-Family New Water Tap(s)&Meter(s) Meter Size(s) 3, •' New Irrigation Meter V Upgrade Existing Meter from 3` to (size) � ., New Reclaimed Water Meter ►/ Size � New Connection to City Sewer V Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# IS- 5# AZ - 2470 Water System Development Charge $ /, /y0, 00 Sewer System Development Charge $ / 0 SO. & Water Meter Only $ /8,5—, co Reclaimed Meter Only $ /83,00 Water Meter Tap $ (notes) Sewer Tap $ Cross Connection $ Sa pa Other $ TOTAL $3;6/0. Od APPROVED: Kayle Moore,PE Z v✓` (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BEASSESSED NOTICE OF COMMENCEMENT I l ,.. State of: FLORIDA Tax Folio No. 169505-2130 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 174 Atlantic Beach Country Club Unit 2,67-132 08-2S-29E Address of property being improved: 574 TIMBER BRIDGE LANE,ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD. HORSHAM,PA 19044 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: Contractor: TOLL BROS.,INC. Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Doc#2015238559,OR BK 17338 Page 676, Name and address of any person making a loan for the construction of Number Pages:1 Name: Recorded 10/16/2015 at 10:08 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL Address: COUNTY RECORDING$10.00 Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): 06/30/17 THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: Date: /0/'$/i 5- Before me is 15 day of OC1-0 . in the County of Duval,State Of Florida,has personally appeared STElj J14(._'7t.. 81-) Notary Public at Large,State of Flo ida,County of Duval. My commission expires:/ �l'7 �f Personally Known: �/ / ' or Produced Identification: _._.. ,ii"; MF_LISS cBERMAN ;10 MY COMMISSION #FF055605 EXPIRES September 18.2017 (4071 350.0153 Floridallotary Service.com ,,.4,,t-,1A.-\\:;,t' sa CITY OF ATLANTIC BEACH J 1`� 800 SEMINOLE ROAD ....„. ATLANTIC BEACH,FL 32233 ...„, (904)247-5800 Revision Request Sheet Date: III I g 115 Received by: Resubmitted: Permit Number: 15 -Sf - 2416 Clearance Sheet Number: r- ik ' ' Original Plans Examiner: ` Project Name: Project Address: x5-7'-4' Ti rvr Bri4tg.e Lan-e, A-- _ Contractor: Toll bra-I 11C Contact Name:___ _l _ ".___ Contact Phone Number: ci D4 2-170-739 Contact Fax Number: _ 1 Revision/PIan Check/Permit Fee(s)Due:$ Description of Proposed Revision to Existing Permit: Pending Hold: tt0_ld Oh Slat pl& v1 . tiros IS a 4-e,u 1ged 5rt Nan duce tD 1 Survt ter mew-city-19 Wron9 tat Size. Pleze se-e. _up Ca-WC' ssr e Ow. ' Plumbing: — - i Mechanical: OFFICE COPY . Electrical: I Misc. 1 -- — Additi onal Increase in Building Value:$ Additional Square Footage: Clear ce Sheet/Site Plan Revised: Environmental Health Approval: By si 'ng below,I i,,;.,�opmeL acs affirm that the above revision is inclusive of the propose i t t _. [111811 . Signa iNre o Contra;/A_'nt(Contractor must sign it increase in valuation) Date i / Office Use Only Date: i /1'a 77¶ Approved: Rejected: Notified by:_X_____ F Plan R4view Commen 19to v Q' S ✓ 6;Yt , "G✓ l (pr p• 2 9'7 s— Plans E iner Date Crated Silo E N -- O 00 -...1 ON LA .A w N --• CO ON LA A w N O " H c-) CA K '° '0 > n7 p C) Y O Y X v) v) va , Po -, = = E4 0 O =. , Z CP 0 S. X r► -s C O -d CD CL. C, ,y . C1.. N -. .i c C O 0 UQ . CD o. o N CD O • p ° arQ _ O QQ �. Co ..■ O. ..t IQ O 0 0 = O '�-., 0) 0 , c ' 0. ,... • Co• C 7.- 0 ~ Cl) UOQ •T7 a 7r 3 S (IQ o o ° w 0- Q a O , - C7 n: 0 n 701 < ^• '; o y 0 ° - p• vs CD a• 0 � w• cr y Q W `(D • ao 0 0 0 0 o 3 H a N C D ` 0• CD y N O CO C 0 a O C p -71 w S II. 0 „d 0 o 0 .,::$_ <r i o c -0 o a a 0 rm Y• = c co C 2' Cl) 4 `< c y .00 � Cs •, y • C. c o -s C, .-1• M• A; 0 'Ti 5'n. < CD < ? 0 aan ,-7•1 4 o N a W 5 W °z vs co CI) `< 0 N n K Y < < < g > ?1 b • a �o "3•E; - a C C C f, C o o 0 p' co -a `Li • u 3 = 9 g O o 0. O o n < x o '5 ;n C y p rn. ^r � ° cA (f0 X s ° ' . K" c n. D -n 6: 1-3 0. y 'Y OS:'? A 1 = G.- 3 B -3 `� 0 0 • . It Y O w z cm LA LA N N z z r - N' O - .� o a o O O o a O " 0. — v1 W Cn to In N N g a n co O co O go co O L7 .9 '; p• 0 -° CI Cl) O ° < -0 > -11 a -+ P o t n O cra E x a = C '1 ft) 5 cn 5 r aQ �- cr 0 vs rr r r r r rrr5' o 5 - u) ,,., v, �„ — v� as C . O. ._. 000 0. 0 00 .A N - tj. y • O N A (WA J N N 0000 CD O O J r d 0 N DD r0n ? ON W r 's7 C CD W � 00 M r O Cr■ N 4t Co (ri A t N C '0 tJ l., r a r , E CD kAl A 0 L31 J ° C, lA .A W N •- C ° 00 --] Fs '✓, A W N — 0 - O J' 00 J ON Us .P W N C) p is o a _,• 0 0 0 S a o o 0 (0 :n p t 1 0 ',' p ° ›. n a - zs m o r < y c c o < F 0 n C'' o c . -n I c ° ---2. ` z m s C; 7- z •s z `- s ° a n 2 a - T A, o '17 _ CD S CD Q, n _— ,n s v, T O_ _0. '0 C% O p„° mss 0 < F. -3 CD "0 CD f1C G v v v r u i 0. 0 0 (IC. (1.:, C; V (r 0 F.- r; r 7 0 0 p p s -r - - - - ✓J ✓: — r a N r f C.. cra v:n a 0 C CD -. a co (1a oa a T `< co (.1 Q 4. .-- j .» n.f _, ff (10 U 7 (D T 7 v,. + z z z z ;> ;= � aa o aaa > w 2. 0 0 0_ C oo N :., 4- J-. 00 t J s rJ C.- - C\ c.) — - t J — O _.• C CD a- VI - • � Y 00 '-'s t Cr — -- FJ — — A — '..., I..)C — — a J C — Oo t — F, i O a 0) It on O N N . . w N C V' oo v Q, to .A W N -- n ;s1 J C. to 4,. W N _ Cs1 = R a CZ O � � � s p o 0 w O � O � Xn � u7ycn I• I' VI Q to .-- Cr ' z y 0 r C o co IQ 0• ° CO CID q o 5. w = co 0 0 L.. C) _N p w --ti 'b r Q. 0 = y C n -I (134 = CD CD ' per) - 3 o w o - °' C C .* n y O '"," m y -t ti _ -t '. -i co CD O O y . 1 3 a. v) on G M 10 CD 0 ,. 0 O c.,, 0 0 w too - 3 (TQ 0 a) d 3 w w 10• C/) 3 G0 0 ^-1 `0 O CD 0 cn rw 2 c- m � i :v 0 n -, - cr co ° o- `� * 0 N r w w t< 3 e) c 0 _ `-I m CD 3 1 0, o (ra co a• `° CD -' a. z_ _ 'No 0 0 L. 0 0 C y ' CI. a DO n) o. a 0 N• .. c w 5; � = N fa.In °' r, `, CD E-0. 0 - o co A) N to (74 (IQ O CD CCD w Cr =' .' C) (IQ V4 It e. E ? R § o a o J « =PO \ /4 z 7 \ z -s > 7, CO , « & a 3 n cr / • 0 ) t, e n 7 « a H k / a - — \ c A / k P z E7 3 - § ■ \ q P 2 < § E § \ G J E \ I o ¢2 k } F 0 5 E. E k d = 2 I m'11 c4 Fr aQ p e_ / § / / C .. C 4 e .0 N a izi 2 § / & I. A o c E E a o - & 0 0 w / g f \ 4h. 0 / \ ƒ = g o § FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Davenport Bonus 2936 Right Builder Name: Toll Brothers Street: 574 Timber Bridge Lane(Lot 174 AB) Permit Office: Atlantic Beach /o City,State,Zip: Ponte Vedra,FL, - Permit Number: i ", �, Owner. Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(2609.2 sqft.) Insulation Area Single-family a.Frame-Wood,Exterior R=19.0 2261.20 ft2 2. Single family or multiple family b.Frame-Wood,Adjacent R=13.0 348.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (2757.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2201.00 ft2 6. Conditioned floor area above grade(ft2) 2936 b.Knee Wall(Vented) R=19.0 556.00 ft2 c. N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(385.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 550 a. U-Factor: Dbl,U=0.34 385.65 ft2 SHGC: SHGC=0.30 ft2 12.Cooling systems kBtu/hr Efficiency b. U-Factor N/A a.Central Unit 42.0 SEER:14.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 3.665 ft. 14.Hot water systems Area Weighted Average SHGC: 0.300 a.Natural Gas Tankless Cap: 1 gallons 8. Floor Types (2936.0 sqft.) Insulation Area EF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 2181.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 735.00 ft2 None c.other(see details). R= 20.00 ft2 15.Credits Pstat • Total Proposed Modified Loads: 67.12 PASS Glass/Floor Area: 0.131 Total Baseline Loads: 71.04 I hereby certify that the plans and specifications covered by Review of the plans and _s,{'00 . 1.6. : this calculation are in compliance with the Florida Energy specifications covered by this A.^'Qv:;;��, t�'�c S. <\�� calculation indicates compliance ; vlk';4i„ q,; =z,;�o\\7�':. Code. with the Florida Energy Code. +r++' `•'''•- E:x''o""+N`�y ' Before construction is completed w: '°?%.s ,. PREPARED BY: ,e���c =/ r f�'� 12 i DATE: �,. this building will be inspected for c ���^ y``�5`� compliance with Section 553.908 `.. °t =r Florida Statutes. "..'rrl,.' '•g'S I hereby certify that this building�oesigned,is in compliance �t CO- �. with the Florida Energy Cod D WE. OWNER/AGENT: BUILDING OFFICIAL: �` --/DATE: 51 I(5 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 8/28/2015 10:18 AM EnergyGaugee USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: Davenport Bonus 2936 Right Bedrooms: 4 Address Type: Street Address Building Type: User • Conditioned Area: 2936 Lot# Owner. Toll Brothers Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Narne: Toll Brothers Rotate Angle: 0 Street: 574 Timber Bridge Lane Permit Office: Atlantic Beach Cross Ventilation: No County: St.Johns Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Ponte Vedra, • Family Type: Single-family FL, - New/Existing: New(From Plans) Comment: CLIMATE V IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range 4 FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block/ 2936 28605 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2181 21810 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 755 6795 No 1 1 1 Yes Yes Yes FLOORS V, # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet ✓� 1 Slab-On-Grade Edge Insulatio Main 186.6 ft 0 2181 ft2 0 0 1 v 2 Floor over Garage 2nd Floor ____ __ 20 ft2 19 0 0 1 v 3 Floor Over Other Space 2nd Floor ____ _— 735 ft2 0 0 0 1 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) V 1 Gable or Shed Composition shingles 2549 ft2 64.4 ft2 Medium 0.6 N 0.9 No 0 30.3 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC V 1 Full attic Vented 300 2201 ft2 N N 8/28/2015 10:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING `/// # Ceiling Type Space R-Value Area Framing Frac Truss Type y/ 1 Knee Wall(Vented) Main 19 • 76 ft2 0.11 Wood "__ f✓ ' 2 Under Attic(Vented) Main 38 1446 ft2 0.11 Wood i 3 Under Attic(Vented) 2nd Floor 38 755 ft2 0.11 Wood V 4 Knee Wall(Vented) 2nd Floor 19 480 ft2 0.11 Wood WALLS Adjacent S Space Cavity Width Height Sheathing Framing Solar Below 1�# omit At cent Type P v iuo Ft in Ft in Area R�iaiue Fraction Abso[_-grade% ✓ 1 E Exterior Frame-Wood Main 19 67 0 10 0 670.0 ft2 0 0.23 0.6 0 1,/`2 SE Exterior Frame-Wood Main 19 12 9 10 0 127.5 ft2 0 0.23 0.6 0 .1// 3 5 Exterior Frame-Wood Main 19 27 11 10 0 279.2 ft2 0 0.23 0.6 0 V 4 W Exterior Frame-Wood Main 19 53 6 10 0 535.0 ft2 0 0.23 0.6 0 V 5 N Exterior Frame-Wood Main 19 20 6 10 0 205.0 ft2 0 0.23 0.6 0 1./ 6 N Garage Frame-Wood Main 13 20 0 9 0 180.0 ft2 0 0.23 0.6 0 Vi 7 W Garage Frame-Wood Main 13 18 8 9 0 168.0 ft2 0 0.23 0.6 0 8 SW Exterior Frame-Wood Main 19 8 0 10 0 80.0 ft2 0 0.23 0.6 0 i/ 9 W Exterior Frame-Wood 2nd Floor 19 20 3 9 0 182.3 ft2 0 0.23 0.6 0 1, 10 E Exterior Frame-Wood 2nd Floor 19 20 3 9 0 182.3 ft2 0 0.23 0.6 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In � '\./ 1 N Insulated Main None .6 3 8 24 ft2 _ 2 N Insulated Main None .6 3 7 21 ft2 WINDOWS - Orientation shown is the entered, Proposed orientation. Wall Overhang / # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening ___• 1 E 1 Vinyl Low-E Double Yes 0.34 0.3 6.6 ft2 1 ft 0 in 4 ft 0 in None Exterior 5 V. 2 E 1 Vinyl Low-E Double Yes 0.34 0.3 37.5 ft2 1 ft 0 in 7 ft 0 in None Exterior 5 Iii 3 E 1 Vinyl Low-E Double Yes 0.34 0.3 37.5 ft2 1 ft 0 in 14 ft 0 in None Exterior 5 V/ 4 SE 2 Vinyl Low-E Double Yes 0.34 0.3 56.3 ft2 8 ft 0 in 0 ft 6 in None Exterior 5 L 5 S 3 Vinyl Low-E Double Yes 0.34 0.3 21.3 ft2 9 ft 0 in 0 ft 6 in None Exterior 5 1/ 6 S 3 Vinyl Low-E Double Yes 0.34 0.3 37.5 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 V1 7 S 3 Vinyl Low-E Double Yes 0.34 0.3 27.1 ft2 9 ft 0 in 0 ft 6 in None Exterior 5 j 8 W 4 Vinyl Low-E Double Yes 0.34 0.3 21.3 ft2 1 ft 0 in 14 ft 0 in None Exterior 5 V/ 9 N 5 Vinyl Low-E Double Yes 0.34 0.3 37.5 ft2 7 ft 0 in 0 ft 6 in None Exterior 5 V/ 10 W 9 Vinyl Low-E Double Yes 0.34 0.3 15.5 ft2 1 ft 4 in 2 ft 0 in None Exterior 5 11 E 10 Vinyl Low-E Double Yes 0.34 0.3 46.5 ft2 1 ft 4 in 2 ft 0 in None Exterior 5 V 12 W 9 Vinyl Low-E Double Yes 0.34 0.3 3.6 ft2 1 ft 4 in 2 ft 0 in None Exterior 5 13 W 4 Vinyl Low-E Double Yes 0.34 0.3 37.5 ft2 1 ft 0 in 4 ft 0 in None Exterior 5 • 8/28/2015 10:18 AM. EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 GARAGE �/ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 440 ft2 420 ft2 64 ft 9 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00031 2383.8 130.86 246.11 .2934 5 HEATING SYSTEM J # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 42 kBtu/hr 1 sys#1 COOLING SYSTEM ✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts V 1 Central Unit Split SEER: 14 42 kBtu/hr 1260 cfm 0.7 1 sys#1 HOT WATER SYSTEM / # System Type SubType Location EF Cap Use SetPnt Conservation V 1 Natural Gas Tankless Exterior 0.59 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage . / Cert # Company Name System Model# Collector Model# Area Volume FEF '/ None None ft2 • DUCTS —Supply— —Return- Air CFM 25 CFM25 HVAC# # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool V 1 Attic 6 550 ft2 Attic 287 ft2 Default Leakage Attic (Default) (Default) 1 1 8/28/2015 10:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ ]Jan [[ Feb [[ ]]Mar Apr Ma X Jun Jul Au Se 8cctt Nov geecc Venting 4X Jan [Xi Feb [X]Mar [X Apr t i May t 1 Jun [ Jul [ Aug �i Sep [XX Oct [XX Nov t Dec Venting ]]Jan [[ Feb [X Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) PM 80 80 78 78 78 78 78 78 80 8 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 68 66 66 66 8 68 68 68 68 68 68 66 Heating(WEH) PM AM 66 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 66 66 • • / • 8/28/2015 10:18 AM EnergyGaugee USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD - r ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index,the more efficient the home. 1 r 574 Timber Bridge Lane (Lot 174 AB), Ponte Vedra, FL, - 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 2261.20 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 348.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2201.00 ft2 6. Conditioned floor area(ft2) 2936 b.Knee Wall(Vented) R=19.0 556.00 ft2 c.N/A R= ft2 7. Windows** Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.34 385.65 ft2 a.Sup:Attic,Ret:Attic,AH:Attic . 6 550 SHGC: SHGC=0.30 b. U-Factor. N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 kBtu/hr Efficient 13.Heating systems Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.665 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation. R=0.0 2181.00 ft2 a.Natural Gas EF:0.59 b.Floor Over Other Space R=0.0 735.00 ft2 b. Conservation features c.other(see details) R= 20.00 ft2 None 15.Credits Pstat Ay , n�4 I certify that this home has complied with the Florida Energy Efficiency Code for Building °•p4'� - ....... Construction through the above energy saving features which will be installed (or exceeded) ,;. = o in this home before final inspection. Otherwise, a new EPL Display Card will be completed . `5,, , F.�- P Y p co r '; ,,,, - based on installed Code co pan features. : ¢ "�!,,, ;gym: ,_��., Builder Signature: Date: 71 3 1 1 1 S 10% I ' n * .. r ss of New Home: n City/FL Zip: t, '� .�-�3 ' q.� ............. � Address 51� -Trnb �,Y►c�19-e. �� f *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/28/2015 10:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 574 Timber Bridge Lane(Lot 174 AB) Permit Number: Ponte Vedra, FL, - MANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. o R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors, if installed at the time of the test,.shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMANVDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. o R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be'substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area. when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 8/28/2015 10:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., O R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies O R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. O R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. O R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected In Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 8/28/2015 10:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity . R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ▪ R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1.• O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. p R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ▪ solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights O R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 8/28/2015 10:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Davenport Bonus 2936 Right Builder Name: Toll Brothers Street: 574 Timber Bridge Lane(Lot 174 AB) Permit Office: Atlantic Beach City,State,Zip: Ponte Vedra,FL, - Permit Number: Owner. Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the.foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and \� framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. \� The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or \� unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be \, sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/28/2015 10:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Davenport Bonus 2936 Right Builder Name: Toll Brothers Street: 574 Timber Bridge Lane(Lot 174 AB) Permit Office: Atlantic Beach City,State,Zip: Ponte Vedra,FL, - Permit Number. Design Location: FL,Jacksonville Jurisdiction: 261300 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: I ELA: EgLA: ACH: ACH(50): SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. HNC,. I hereby certify that the above envelope leakage Where required by the code official, C) .. tZs performance results demonstrate compliance testing shall be conducted by an •\.' ; . 0.;°; with Florida Energy Code requirements in approved third party. A written '- 1. accordance with Section R402.4.1.2. report of the results of the test shall :w r":4+-40R be signed by the third party g conducting the test and provided to * t SIGNATURE: the code official. PRINTED.NAME: BUILDING OFFICIAL: DATE: DATE: 8/28/2015 10:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Softwar Page 1 of 1 McGowan's Project Summary Job: 574 TBL-Lot 174 AB Date: 8/28115 Heating&Air ` Entire House By: Stephen Barber Conditioning `- McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:koreytmcgowansac.com Web:www.mcgowansac.com Pro'ect Information For: Steve Merten, Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Notes: The Davenport Bonus Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 96 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 21 °F Daily range M Relative humidity 50 % Moisture difference 48 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 32687 Btuh Structure 25241 Btuh Ducts 4166 Btuh Ducts 5005 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36853 Btuh Use manufacturer's data n Rate/swing multiplier 1.01 Infiltration Equipment sensible load 30488 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3930 Btuh Ducts 750 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2936 2936 Equipment latent load 4680 Btuh Volume (ft') 29077 29077 Air changes/hour 0.32 0.16 Equipment total load 35168 Btuh Equiv.AVF (cfm) 155 78 Req.total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade 14 SEER PURON HP Trade 14 SEER PURON HP Model CH14NB0420000A Cond CH14NB0420000A AHRI ref 0 Coil FB4CNP042L AHRI ref 0 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 28 °F Total cooling 40000 Btuh Actual air flow 1333 cfm Actual air flow 1333 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i wrightso1 Comfort Builder by Wrightsoft 15.0.17 RSU12270 2015-Aug-28 09:40:01 �� Page 1 ..thers\Davenport Bonus 2936 Right Lot 174 AB.rup Calc=MJ8 Front Door faces: N ire Al ■ First Floor 3'Fan 6x10 6" M.Bath 12• Master 10x6 -- . \ 6..GG�� / I. 4. °;:,:4,1' `^^?1Larmiry 66x if T.' t� ' � N16 MwIC ai 10x10 " 6' 4x6 - �% I 9- 4.• 3"Fan 10 x 10 Ai clst Ret Riser t Great 16x16 r` 12'.. R 6x12 �T/ 6x10 -,,,N Sup Rise 12" Po ee- _ l Dining_ !nc!x`n ... x J 12 x 1z l 10x6 12x12 9.• J 6" 18x24... 6 18 6x12 6�„2 ant: Beef 3 10x6 �.. .._ 6•• Brd 2 %o.^,k _...___ 6 x 12 I. Bath 2 8 3”Fan c ...,, G o PA Job #: 574 TBL - Lot 174 AB McGowan's Heating & Air Conditions... Scale: 1 : 128 Performed by Stephen Barber for: Page 1 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.17 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Aug-28 09:41:38 Phone:(904)217-0739 Fax:(904)814-8173 www•mcgowansac.com korey @mcgowansac.com ...Bonus 2936 Right Lot 174 AB.rup www.tollbrothers.com smerten @tollbrothersinc.com ■._4e •� ■ 2nd 3-Fan Zs.r4 Lath 3 6 x 10 L:•d 4 6" 14x6 6" ss„ 16x16 14 x 6 ►I 12" 8•' Ret Riser • 12" Sup Riser • • 12' 12" loft 14 x 6 8" Job #: 574 TBL - Lot 174 AB McGowan's Heating & Air Conditions... Scale: 1 : 128 Performed by Stephen Barber for: Page 2 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.17 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Aug-28 09:41:39 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey @mcgowansac.com ...Bonus 2936 Right Lot 174 AB.rup www.tollbrothers.com smerten @tollbrothersinc.com McGowan's Duct System Summary Job: 574 TBL-Lot 174 AB Date: 8/28/15 Heating E Air a P fie Entire House By: a Con:ido:ling B Ste hen Barber ....t...- a.c i . t:J McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey @mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten, Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.258/0.132 in H2O 0.258/0.132 in H2O Lowest friction rate 0.073 in/100ft 0.073 in/100ft Actual air flow 1333 cfm 1333 cfm Total effective length (TEL) 534 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 2 h 974 35 23 0.113 5.0 Ox 0 VIFx 33.7 195.0 st4 Bed 2 h 4675 169 85 0.110 7.0 Ox 0 VIFx 38.5 195.0 st4 Bed 3 c 1307 50 58 0.113 6.0 Ox 0 VIFx 37.2 190.0 st4 Dining c 2107 84 93 0.073 7.0 Ox 0 VIFx 73.3 280.0 st7 Foyer h 2170 78 57 0.116 6.0 Ox 0 VIFx 32.6 190.0 st4 Great-A h 3537 128 77 0.075 7.0 Ox 0 VIFx 63.7 280.0 st7 Kitchen c 1866 47 82 0.074 7.0 Ox 0 VIFx 68.0 280.0 st7 Laundry h 425 15 11 0.111 4.0 Ox 0 VIFx 31.8 200.0 st5 M wit c 19 0 1 0.090 4.0 Ox 0 VIFx 47.5 240.0 st6 M.Bath h 2497 90 76 0.113 6.0 Ox 0 VIFx 27.8 200.0 st5 Master c 1802 77 79 0.096 6.0 Ox 0 VIFx 38.8 230.0 st6 Master-A c 1802 77 79 0.095 6.0 Ox 0 VIFx 41.3 230.0 st6 Nook h 2888 104 73 0.074 7.0 Ox 0 VIFx 67.9 280.0 st7 Toilet c 45 2 2 0.118 4.0 Ox 0 VIFx 27.8 190.0 st5 bath 3 c 1094 45 48 0.105 6.0 Ox 0 VIFx 60.7 185.0 st3 bed 4 c 3262 95 144 0.108 8.0 Ox 0 VIFx 54.3 185.0 st3 loft c 3913 117 172 0.112 8.0 Ox 0 VIFx 46.1 185.0 st3 loft-A c 3913 117 172 0.109 8.0 Ox 0 VIFx 51.7 185.0 st3 - wri htsoft" 2015-Aug-2809:40:01 9 Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 ACA ...thers\Davenport Bonus 2936 Right Lot 174 AB.rup Calc=MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 375 537 0.105 684 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 375 537 0.105 684 12.0 0 x 0 VinIFIx st4 Peak AVF 333 223 0.110 611 10.0 0 x 0 VinIFIx st2 st5 Peak AVF 625 573 0.073 585 14.0 0 x 0 VinIFIx st2 st2 Peak AVF 959 796 0.073 687 16.0 0 x 0 VinIFIx st7 Peak AVF 364 325 0.073 463 12.0 0 x 0 ViniFlx st6 st6 Peak AVF 518 485 0.073 659 12.0 0 x 0 VinIFIx st5 Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rsb4 Ox 0 140 192 181.0 0.073 352 10.0 Ox 0 VIFx rt4 rb4 Ox 0 255 214 133.6 0.099 731 8.0 Ox 0 VIFx rt2 rb3 Ox 0 169 85 137.1 0.096 383 9.0 Ox 0 VIFx rt2 rb5 Ox 0 234 345 151.9 0.087 439 12.0 Ox 0 VIFx rt4 rb1 Ox 0 534 497 169.6 0.078 500 14.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt4 Peak AVF 375 537 0.073 684 12.0 0 x 0 VinIFIx rt3 rt2 Peak AVF 959 796 0.078 543 18.0 0 x 0 VinIFIx rt1 rt3 Peak AVF 375 537 0.073 684 12.0 0 x 0 VinIFIx rt1 rt1 Peak AVF 1333 1333 0.073 755 18.0 0 x 0 VinIFIx 2015-Aug-28 09:40:01 ^. W 1'Igf 1tsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 � AC ...thers\Davenport Bonus 2936 Right Lot 174 AB.rup Calc=MJ8 Front Door faces: N Manual S Compliance Report Job: Lot 174 AB McGa�wanys, p Date: 8/28/15 Heating&Air Conditioning Entire House By: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey @mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 34786 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 3565 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 38351 Btuh Indoor RH: 50% Estimated airflow: 1333 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L++TXV Actual airflow: 1333 cfm Sensible capacity: 34786 Btuh 100% of load Latent capacity: 3565 Btuh 100%of load Total capacity: 38351 Btuh 100%of load SHR: 91% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 33559 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A+FB4CNP042L++TXV Actual airflow: 1333 cfm Output capacity: 40000 Btuh 119%of load Capacity balance: 28 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1333 cfm Output capacity: 9.8 kW 100% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Aug-28 10:20:52 wrightsoft Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 1 A+CN l:1300 RES NC\Toll Brothers\3.5 TON Manual S.rup Calc=MJ8 Front Door faces: N