Loading...
365 8th ST - REVISION RETENTION POND e CITY OF ATLANTIC BEACH } 800 Seminole Road Atlantic Beach,Florida 32233 a��9 Telephone(904)247-5800 "'� :;,`,""' FAX(904)247-5845 �wilb, REVISION REQUEST SHEET Date: I1 2e - Received by: Resubmitted: Permit N tmbe l`' \5 \°N\y Original Plans Exa� . Cep-rr Project Name: lr m,s�.ld Project Address: 5 $T�' Sr• Contractor.__Mc Qye�y T{� �n�r�_� Contact Name: A,,,Am Contact Phone : cJQ4 - R 1- R 1 3 -1-7-7 R-7-7 R Contact e-mail: a 1. � ..,.a„a„ 6„ •�,�Q.-. h„„ Revision/Plan Check/Permit Fee (s)Due: $ T— Description of Proposed Revision to Existing Permit: C-HA,JC,a C208A RF_- jn.� DpNn T 6U .rte1 ,13,FgCE __1LC LTA4'{_,nwl 54_$TM _ Additional Increase in Building Value: $ - 0- Additional S.F. - n Site Plan Revised: It 25 /{ Public W/U Approval: By signing below. I (print oaFnc)_JO 4PPN w '�" pAJ4A r4 affirm that the above revision is inclusive of the proposed changes. 1 JJ '4z I-,] �� Ate E Sigitatureof Contractor/Agent(Comnradorntua�;rgn Uicr in v4ualio Dat D Oaice Use ON 2b el.115— Date: IZ troveJ: Rejected: _ Noifi avy: Plan Review Comments: Department review required Yes No Building Planning &Zoning Tree Administrator ns examiner Public Works Public Utilities _ / — Public Safety _ Fire Services Date 252 Otterwood Ct Jacksonville, FL 32225 Mr Doug Layton Mr Scott Williams Department of Public Works City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 Re: Stormwater Management System 365 8th Street,Atlantic Beach Dear Doug and Scott: Enclosed is our Revision Request Sheet to permit installation of a subsurface Stormwater Management System at the above referenced residential lot. The original plan was for a retention pond but the ownerhas opted for the system described herein for reasons of public health and enjoyment of their limited backyard. The Plan reflects the several discussions we have had over the past few weeks. It is considerably simpler than any of the conceptual plans I showed you as well as distributing stormwater falling on the site more broadly around the site. I am confident that it will handle almost any foreseeable precipitation event. Thanks for the patience you've shown in helping me get up to speed on this issue. Please contact me should you have any questions or comments on the enclosed. Very truly yours, Joseph W Sheahan Consulting Hydrogeologist Encl Cc: Adam Smythers (w/encl) Ed Hebert (w/encl) 365 8th LTR 112415a.Dol 11/24/15 22:27 SPECIFICATIONS STORMWATER MANAGEMENT SYSTEM 365 B'b Street Atlantic Beach, FL November 24, 2015 BACKGROUND The City of Atlantic Beach requires that stormwater falling on sites of new construction must be managed on site, i.e., ideally no stormwater from the site will discharge to the city's storm sewers. The architect of the house under construction at the site has calculated that the rain event specified by the city could produce 2,155 cubic feet (ft) or 16,371 gallons of stormwater; this becomes the storage volume required by the city. The conventional approach - stormwater retention basins - entails several drawbacks including serving as mosquito breeding grounds, undesirable from a public health perspective. SYSTEM CAPACITY The design objective was to find 2,155 ft' of stormwater storage space in some combination of subsurface piping volume plus the pore space in the lower 3.5 feet of unsaturated soils underlying the site. The approach taken is to use slotted corrugated pipe to distribute the stormwater to the unsaturated soils. The site was divided into four areas for the analysis. The attached spreadsheet presents the calculations of storage volumes for different pipe sizes in each area. The cells stippled and shaded blue contain the options selected to attain the required volume with 4°% excess capacity. The Proposed Layout, Stormwater Management System shows the system configuration based on the spreadsheet and input from the drainage contractor. The calculations probably merit some explanation. 1 divided the site into four areas, North, East, South and West. The North Area is the backyard where the Retention Pond was to go. The East Side is a narrow strip between the new house and the adjacent lot. The South Area is now a courtyard and the front yard of the property; tiles were installed in this areas before the courtyard walls were poured to handle downspout Flow. Finally, the West Area is the driveway serving a side-load garage on the ground level; the driveway is being finished with pervious pavers. 365 specifications 112415b.Uocx 1 11/20/15 21:52 The city recognizes the capacity of the pore space in the unsaturated soils (i.e., above the water table) to hold stormwater. In calculating the site-specific available pore volume, the city assumes a soil porosity of 30% and a watertable elevation of 3.0 feet. These parameters are incorporated in the spreadsheet. The first column shows the minimum length of slotted pipe to be installed in a given area..The south and east sides have two relatively closely spaced slotted pipes each. The second column shows that, due to the pipes' proximity, each side is assumed to have an infiltration area only two feet wide, or one foot per tile. As we discussed, each pipe actually discharges to a considerably wider area. The second column shows that the three tiles spaced on four-foot centers in the wider North and West Areas, discharge to an area 12 feet wide, consistent with the plan with which you had at one time concurred for the North Side. Both of these areas have considerably greater areas and volumes to handle any infiltrating water. In all cases, I have assumed a conservative 3.5 feet of unsaturated soils beneath the pipes to absorb the infiltrating waters. These values are combined with the City's default value of 30% porosity to yield the total unsaturated pore volumes calculated in the Column titled 30% Volume,ft'. As shown at the bottom of that column, the unsaturated soils can hold 2,098 ft3 of the 2,155 ft' required The next section of the spreadsheet calculates the volumes of the lengths of pipe specified in Column 1 for various pipe diameters to permit optimization of the system design. Six-inch corrugated, slotted HDPE pipe was chosen for all four areas, yielding an additional 138 ft' of storage volume. The total volume in the system so designed is 2,336 ft3, or 4% more than required. SYSTEM DESIGN The infiltration system is designed to serve a purpose completely opposite from most piping systems. Typical gravity piping systems are designed to convey liquids from Point A to Point B, as efficiently as possible with no loss of the contents of the system. An infiltration system, conversely, is designed to allow all of its contents to leak out and prevent discharges from the end of the system. The infiltration system will be installed with all pipe inverts on the north, south and east sides set at an elevation of 6.5 ft., or 3.5 feet above the assumed water table, i.e., 1.0 foot below the final site grade of 7.5 ft. (NAVD88). The tiles under the drive on the west side of the property will be set at an invert elevation of 6.3 ft to accommodate the overlying pervious pavers. Cross 365 specifications 112415oDoa 2 11/24/15 21:52 section A - A' shows the placement of the tiles under the drive relative to the fill placed to bed the pavers. The infiltration gallery will end at an overflow outlet box which is designed to prevent water from seeping to the surface should the infiltration gallery ever become overloaded. The invert of the discharge from the overflow structure will be set at an elevation of 7.0 ft, i.e., at the top of the inside of the 6" corrugated pipe in the infiltration gallery at its far extent. The overflow structure will gravity drain to an overflow discharge adjacent to the driveway and behind the sidewalk. Prepared by: Joseph W. Sheahan Consulting Hydrogeologist 365 Specifications 112415b.Docx 3 11/24/15 21:52 ' ao s i < f s w O i m N m r f " o m C W WT d m N • a a w e s E i n g ? GO 3 M c d oY O � x � Sa : - a o � a o - �' zo r w i - � Y a6 p 0 _ 0 a 'E o 'a r a N � a ao i O o p a > p o = Y a _. O LL a N ? + a aw m v s 2 c o � C 0 a a =- h .R-- f q No o y o°Do LL CE m > p a Z S p c m ? W u O r r p l N o w > a ^ O z W m o 3 v U w a y m u �J Q 0 pNp .n �p V V1 Q W 0 J F— QJ N = r L Q ++ N Q y Lu N VI l O LnLn E a s o a > o a v I a spa d f/f M Z a $ d v a ? m r m Y Lr! \ o � � 0 .. J D � lV S � u u �J1 r1i � r' M `[ I w J LL cLU fp Ul Z a Q Q T = UL z Q ami ro O W o Ll M - --.3sa C ? F. F- L1 N GJ Z . x W N N O W N i w V) CC 0 ai 0 O a y a D � > a O �V V c% � z a M j � I x ` Q 1 I qj tutu N N tj¢ e Li > 3 N x n C - - , e -579 T.rA, «..a-.a K s .,y C� / 6076 36 70 FRe o f PPE !o Eck. o 42 S L1a li„ Comp. By: SRW J '- Date: 11/20/2015 J'S19/ Public Works Department City of Atlantic Beach Permit No: Address: 365 8th Street Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning,Subdivision,and Land Development Regulations requires that the difference bely een the pre-and posldevelopmenl volume of stonnwawler runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feel R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area(A) = 10,816 ft' Runoff Coefficient Area Lot Area Description (fte) (ft) C. Wtd "C" Impervious 1,777 10,816 1.00 0.16 Pervious 9,039 10,816 0.20 0.17 Runoff Coefficient(C)= 0.33 Runoff Volume V= 0.33 x 10,816 x 9.3 I 12 V= 2,778 ft' Postdeveloumenl Runoff Volume: Lot Area(A) = 10,816 ft' Runoff Coefficient Area Lot Area Descrip8on ffex) (flr) "C" VM"C" Impervious s, 10,816 1.00 0.49 %ISA= 48.6% Pervious 5,564 10,816 0.20 0.10 Runoff Coefficient(C)= 0.59 Runoff Volume V= 0.59 x 10,816 x 9.3 1 12 V= 4,933 ft' Reauired Stomps Volume DV= Posldevelopment Runoff Volume-Predevelopmenl Runoff Volume DV= 4,933 - 2,778 DV= 2,155 its Retention 8th Stmet865 11)20MI5 s�Lv>� Comp. By: SRW Date: 11/20/2015 •a 91' Public Works Department City of Atlantic Beach Permit No: Address: 365 8th Street Provided Storage: Elevation Area Storage 0 BOTTOM 0 TOB Elevation Area Storage (ft) (ft') (ft') 0 BOTTOM 0 TOB Elevation Area Storage (ft) (k') (ft') 0 BOTTOM 0 TOB Inground storage=A'd'pf A=Area= 0.0 d=depth to ESHVPT= pf=pore factor= 0.3 Inground Storage= 0.0 ft3 Required Treatment Volume= 2,155 ft3 .F73 Supplied Treatment Volume= 0 ft' V RetenWn Stn Street365 11/20/2015 SPECIFICATIONS qi,J1. P /RESIDENTIAL SITE DRAINAGE SYSTEM / 3LOg`"Street pi Atlantic Beach, FL { I I t wBACKGROUND The City of Atlantic Beach stipulates that stormwater falling on sites of new construction must be managed on site, i.e., ideally no stormwater from the site will discharge to the city's storm sewers. The architect of the house under construction at the site has calculated that the specified rain event could produce 2,155 cubic feet (ft3) or 16,371 gallons of stormwater. The city requires that the site be able to retain that much water. The conventional approach - stormwater retention basins - entail several drawbacks including serving as mosquito breeding grounds, undesirable from a public health perspective. SYSTEM CAPACITY SYSTEM DESIGN The city appropriately recognizes the ability of the pore space in the unsaturated soils (above the water table) to hold stormwater. In calculating the site-specific available pore volume, the city assumes a soil porosity of 30% and a depth-to-water of 3.0 feet. The infiltration system is designed to serve a completely opposite purpose from most piping systems. Typical gravity piping systems are designed to convey liquids from Point A to Point B, as efficiently as possible with no loss of the contents of the system. In an infiltration system, ideally all of the contents leak out before they can discharge from the end of the system. The infiltration system will be installed with all pipe inverts set at an elevation of 6.5 ft., or 2.0 feet above the assumed depth of the water table in the rear(north end)of the site, i.e., 1.0 foot below the final site grade of 7.5 ft. at the north end of the site. The infiltration gallery will end at an overflow structure which will prevent water from seeping to the surface should the infiltration gallery ever become overloaded. The invert of the discharge from the overflow structure will be set at an elevation of 7.0 ft, the top of the inside of the 6" corrugated pipe in the infiltration gallery at its distal extent. The overflow structure 635 Specifications 110315a.Docx 11/3/15 0&16 n 0 I I n 0 1 0 V p o 41 T a � I � 0 N I N fP n � o I I � I I n 0 G a f y] u will be piped to a catch basin in 8t" Street at Sta 7+37. The overflow pipe will be connected directly to the catch basin below grade. 635 Specifications 110315a.00v 11/3/15 08:16 &' i V C It : dY iviiyi 3 � dI�� m'5 P1, 8 m ° r m o - GC&&" tom m ISI „ o S? an - u ° � o a � N x � 6 `1` ►a v99 q_3 �L $ 3 ' ut 3 v n nn w v m � x s 0 w z c wo gm � N c a ^ N n n N N uZ b 0 G � 2 o � x w � g 3 ; 3 m � v c w o n y o z -zi z o a v 3 0 nn N � N i 0 n a � U x � _ rn � J n N D — W o J C Z ' - \f _ 2 a ,crj h I n� I 1 m 3 a n n a � o O _ C m . O s a m F x g n x , s 3 u m i w c g s $ m i WSW 3 � A W 3 z � e w N 3 m a . m D - < y N — O o m O s � O N � O O c < x 3 3 3 N m 3 o n JIB m 3 P n o m o o m w r w Z D ^' S m W � 3 " cm 'n m � n z 6 0 n < n n o 1 c n N 3 a 0 c G m � z z 3 < s9 d ^a O O d R T � O N O 3 3 ° i � O n p n o D ^I q n3 a F q e q � I .ai\G Y • rrta Ltir / w\\\t t III NINA _ .�CydiY/\\/1S�\iSSi�e/tYSi. /S rrrJiAA r r / / ON y`whaeN .w'\ weNett\t\.\\t /iAiriir vii / s FrA 'IIr IIIIf NI 3III 'H/ JIII AAA//. r6lr - ;• aY\hS\\ey\wY otew.w rtwtYSNN�a>Y.-YNN\ \ • ,� \rtr\YL�LLre1/�\LF�.(IIe/\',,II!�'� •IHIIIII •^ I`IYI\II�I`Js°1°!✓ IiI`11•°iYii ' II/IAIN IIA IIIIIA// q`.eheNN4t\WNNNR •IOIlIIAAY'r OJ aIIIIIFIC. NINE/i•!h'N•dI)' FhwY\.W.Ntv,\�r I/NIs�.'hVIII y, N• a\\ ;I Ie YI II�IINII S . w eN\Ntw. NAAIIAII II , \tk1\)\A\I�\t� A\7 �D Comp. By: RLC Date: 9/16/2014 Public Works Department yf l City of Atlantic Beach / Permit No: 13-tbd Address: 365 STH STREET Required Storage Volume Criteria: Section 24-08 of the City of Atlantic Beach's Ztxung,Subdivsim,and Land Development Regulations requires that the difference between the pre-and postdavelopmem volume of starmwawter runoff be stored on site. Volume of Runoff Is defined as follows: V=CAR/12 Where: V-Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predevelopment Runoff Volume, Lot Area(A) - 10,816 ft2 Runoff Coefficient Area Lot Area Description (ft') (R) "C' Wtrl"C" Impervious 1,777 10,816 1.00 0.18 Pervious 9,039 10,816 0.20 0.17 Runoff Coefficient(C)= 0.33 Runoff Volume V= 0.33 x 10.816 x 9.3 1 12 V= 2,778 ft' Postdeveloomern Runoff Volume: Lot Area(A) = 10,816 ft2 Runoff Coefficient Area Lot Area Description (ft') (ft') "C" Wtd"C" Impervious 5,252 10,816 1.00 0.49 Pervious 5,564 10,816 0.20 0.10 Runoff Coefftclenl(C)= 0.59 Runoff Volume V= 0.59 x 10,816 x 9.3 1 12 V= 4,933 ft, Reaulned Storage Volume DV= Postdevelopment Runoff Volume-Predevelopment Runoff Volume DV= 4,933 - 2.778 DV= 2,155 fte Retention 1402 Repuhetl Stora9a Volume 9116/2o14 Comp. By: RLC Date: 9/16/2014 Public Works Department City of Atlantic Beach Permit No: 13-lbd Address: 365 8TH STREET Provided Storage: Elevation Area Storage (ft) (ft) (11) 0.0 754 0 BOTTOM 0.5 1,303 514 TOB Elevation Area Storage (ft) (ft2) (ft) 0.0 268 0 BOTTOM 0.2 1,036 136 TOB Elevation Area Storage (ft) (ft ) (fill 0.0 0 0 BOTTOM 0.5 0 0 Toa Inground storage-Mtrpf A=Area- 2339.0 d=depth to ESHWr= 3.0 pf=pore factor= 0.3 Inground Storage= 2105.1 ft° Required Treatment Volume= 2,155 ft2 Supplied Treatment Volume a 2,755 ft2 �J\S rr' a.wvw .2_9e9WrW%iv Vdum. 911eWla s I' l W7 W W N N V -qp J fZ O � U � O Z D 3 C u p � L Q J eul P W w T O N d M � N d a. �n u � n � �b i { J QIQ