Loading...
1811 SELVA MARINA DR - HVAC -i r�J\ �� r Jai , ' 1* \S, CITY OF ATLANTIC BEACH kr i'�,; 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 � JS31�r' MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-2812 Job Type: MECHANICAL HVAC ONLY Description: 1 CU 1 AHU 4 TONS Estimated Value: $5,553.00 Issue Date: 12/4/2015 Expiration Date: 6/1/2016 PROPERTY ADDRESS: Address: 1811 SELVA MARINA DR RE Number: 172020-0764 PROPERTY OWNER: Name: WHITTEN, JACK E Address: 1811 SELVA MARINA DR GENERAL CONTRACTOR INFORMATION: Name: OCEAN STATE HEAT & AIR,INC. Address: 1476 ATLANTIC BLVD QA JAMES GLENN JONES Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Trade Permit Base Fee $55.00 Furnaces and Heating $24.00 AC and Refrigeration $32.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Total Payments: $115.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. I MECHANICAL PERMIT APPLICATION rYIC`13e • CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904)247-5845 .OB ADDRESS: 1211 SeJ Va_ i\lAcdpc, D Co PERMIT# PROJECT VALUE$ 5 5S3 00 ARI#, (0°1 MS P REQUIRED i _Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only 1EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED • tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit 1---A'kW S l See Heat: Unit Quantity 1 BTU's Per Unit 'r�COO Seer Rating Duct Systems: Total CFM REQUIRED SIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) "• . Fire Suppression Systems. . Quantity (Requires 3 sets of plans) ■IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty ^. Automobile Lifts Gas Piping Outlets • Boilers BTU's Elevators/Escalators k.LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets • • Pumps #Vented Wall Furnaces ' Refrigerator Condenser BTU's # Water Heaters , - Solar Collection Systems • _ Tanks(gallons) . Wells )THER: ED ennit becomes void if work does not corn ce within a six month period or work is suspended or abandoned for six months.I hereby certify that I have nu- lls application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether speciliet at. The permit does not give authority to violate the proviis'Ion_s of my other state or local law regulation construction or the performance of construction. 'roperty Owners Name 1" 1 e t a, V" t`li b l . . Phone Number '24 C 2t) Mechanical Company V CeCt.lr‘ . Cam , SKr- 1 Office Phone2`icI 2S1 Fax 2 - N 9 :o. Address: -'\--A IP Af C.n.''h/d 13,1\A. City NyfUrE. ' lhtate FL- Zip ___ ,icense Holder(Print): - C _L,:uu.tu,At / ' ..,,--- ification/Registration# Critt)-1g3k) lotarized s::,, i to Hol, • �_,1 K+irB�r� ALE • ., NOTARY PUBLIC Before me this No' i f [eCem 20 5- +�� :=STATE OF FLORIDA . commt+~EE879174 .•nature of No : Public UJC-Lt,I Expires 3/2/2017 ç)/)' �2)l2__f U This combination qualifies for a Federal Energy rlu :i CERTIFIED' Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2014. www.ahridirectory.org LIC Certificate of 1rb w . , 4.41 ert` AHRI Certified Reference Number: 6936859 Date: 12/2/2015 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HCB648A**31 Indoor Unit Model Number: FV4CN(B,F)005L Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER AIR CONDITIONING Series name: PERFORMANCE 16 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 47000 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 16.00 Heating Capacity(Btuh) @ 47 F: 46500 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 29200 • • 'Ratings followed by an asterisk('I Indicate a voluntary rerale of previously published data,unless accompanied with a WAS..vnich indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to.and assumes no responsibility for. the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at TERMS AND CONDITIONS UM This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual.personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced:copied;disseminated: • entered into a computer database;or otherwise utilized,in any form or manner or by any means.except for the users individual, personal and confidential reference. AIRCONDITIONING.HEATING. CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at , w,ahridircetory.org,click on`Verify Certifica 'link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above.and the Certificate No„which Is listed at bottom right. 130935460166689488 ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: