173, 177, 181, 185 OCEAN GATE DR - ENERGY SHEETS OFFICE COPY C7 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-QUADPLEX-OUTSIDE-A-R-173 Builder Name: BEACHES HABITAT Street: 173 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: 5-- S rA T "a b?4/3 Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(1637.3 sqft.) Insulation Area 2. Single family or multiple family Multi-family a. Frame-Wood,Exterior R=19.0 1138.70 ft2 b. Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (605.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area above grade(ft') 1170 b.N/A R= ft2 R= ft2 Conditioned floor area below grade(ft2) 0 c N/A R R ft2 11.Ducts 7. Windows(130.0 sqft.) Description Area a.Sup:1st Floor,Ret: 1st Floor,AH:Attic 6 165 a. U-Factor: Dbl,U=0.30 130.00 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 22.7 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 23.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems a. Electric Cap:40 gallons 8. Floor Types (605.0 sqft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 b. Conservation features b.N/A R= ft2 None 2 c• R= ft 15.Credits Pstat Total Proposed Modified Loads: 27.52 Glass/Floor Area: 0.111 PASS Total Baseline Loads: 31.69 ' I hereby certify that the plans and specifications covered by Review of the plans and 'tl�B ST 4 .. ........Aro''•••. this calculation are in compliance with the Florida Energy specifications covered by this ��Y s 04.:... Code. calculation indicates compliance 'yam:,,,��,... i _ ,1'...tt,•; with the Florida Energy Code. I I- nn, . "'.4. p': PREPARED BY: J FERNANDEZ(ESIGN) Before construction is completed ; W -y. ,•.may C !� 4 DATE: 11/2015 this building will be inspected for ` OL irl�' _ ,z_ 0 = compliance with Section 553.908 '; , �° .�1'1, * :` I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Co M Cpp WE.- v•: : OWNER/AGENT: BUILDING OFFICIAL: // ` /- DATE: //- it -i'_ DATE: ti/ id'02 g`l SI- - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 11/4/2015 1:43 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: HABITAT-QUADPLEX-OUTSI Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1170 Lot# Owner: Total Stones: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 270 Street: 173 OCEAN GATE DRI Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 1170 9360 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 565 4520 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 605 4840 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 605 ft2 ____ 0.2 0 0.8 ROOF V/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 638 ft2 100 ft2 Medium 0.85 No 0.9 No 0 18.4 VATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 605 ft2 N N CEILING ✓ # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 605 ft2 0 Wood 11/4/2015 1:43 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # rlrnt Tn Wall Typo Space R-Values Ft In Ft In Araa R-Valna Frartinn Ahmr hrarir+"/ , 1 N=>W Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 2 E=>N Exterior Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 3 S=>E Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 4 W=>S Neighbor Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 5 N=>W Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 6 E=>N Exterior Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 7 S=>E Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 8 W=>S Neighbor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated 1st Floor Metal .46 3 6 8 20 ft2 2 S=>E Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 6 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 7 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed CFM(50) .1 .00 .01 .0000 .0003 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 23.55 kBtu/hr 1 sys#1 11/4/2015 1:43 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 22.71 kBtu/hr 681 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ---Supply--- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [X]Jan [X]Feb [X)Mar [X]Apr (X)May X)Jun [X]Jul [X]Aug g K12,37 [X)Oct [Xj Nov IX)Dec Heating X Jan X Feb X Mar [[X]]Apr [[X]]May X]]Jun [[X]]Jul [[X]]Au [ ] [[X)]Oct [[X])Nov [[X]]Dec Venting X Jan X Feb X Mar X Apr X May X Jun X Jul X Aug X Sep X Oct X Nov X Dec Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 11/4/2015 1:43 PM EnergyGaugee USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. 173 OCEAN GATE DRIVE, ATLANTIC BEACH , FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 ft2 b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area(ft2) 1170 b.N/A R= ft2 c.N/A R= ft2 7. Windows** Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.30 130.00 ft2 a.Sup:1st Floor,Ret: 1st Floor,AH:Attic 6 165 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 22.7 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 23.6 HSPF:8.50 Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 a.Electric EF:0.92 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building "".. Construction through the above energy saving features which will be installed (or exceeded) ;:•D*ZH6 STgj.•., in this home before final inspection. Otherwise,a new EPL Display Card will be completed :1,21,;;,, ',,,,•. based on installed Code compliant features. :i.:'�,,, ."''' •3,, 0 i 0` U'Builder Signature: Date: /- // S .4 s _ o _•Address of New Home: • .Y • 1 �� QCac.�,�1�e �'1• City/FL Zip: ��..�t i��c�•`'•.!�'' �........ .4S.•/' ..... .................... *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/4/2015 1:44 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Florida Code 2014 Summary Report Title: HABITAT-QUADPLEX-OUTSIDE-A-R-173 TMY City: FL_JACKSONVILLE_ Util:OCEAN GATE DRIVE FLProp2014 Elec il: Florida Average ATLANTIC BEACH , FL, 32233 Gas Util: Florida Average Registration#: Run Date: Energy Uses Reference Home Proposed Home e-Ratio Heating 2.43 MBtu 1.37 MBtu 0.56 Cooling 5.66 MBtu 4.95 MBtu 0.87 Hot Water 8.58 MBtu 8.94 MBtu 1.04 Total 16.67 MBtu 15.26 MBtu 0.92 Building Loads Reference Home Proposed Home e-Ratio Heating 5.13 MBtu 2.89 MBtu* 0.56 Cooling 18.15 MBtu 15.87 MBtu* 0.87 Hot Water 8.41 MBtu 8.76 MBtu* 1.04 Total 31.69 MBtu 27.52 MBtu 0.87 * normalized modified loads Glass/Floor Area: 0.111 Total Proposed Modified Loads: 27.52 PASS Total Reference Loads: 31.69 11/4/2015 1:44 PM EnergyGauge®USA-FlaRes2014/ Page 1 of 1 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-QUADPLEX-OUTSIDE-A-R-173 Builder Name: BEACHES HABITAT Street: 173 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/4/2015 1:51 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 173 OCEAN GATE DRIVE Permit Number ATLANTIC BEACH ,FL,32233 I MANDATORY REQUIREMENTS See individual code sections for full details. %] 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. i R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. c R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed. beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust.intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures: 3. Interior doors, if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test.shall be turned off:and 6.Supply and return registers,if installed at the time of the test.shall be fully open. O R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2).and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. 1St R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. g] R403.2.2 Sealing(Mandatory)41l ducts, air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers.shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes.or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55`F(13°C)shall be insulated to a minimum of R-3.. C R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight,moisture,equipment maintenance.and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. Sl R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies C R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation.Commercial Provisions.for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806.Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code, Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. G R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality. shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics.crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. o R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data. the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. • R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. o R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. • R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 55`F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40`F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. o R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2. Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. o R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. o R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ▪ solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights • R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. o R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 Manual S Compliance Report Job: QUADPLEX-OUTSIDE UNI... wrightsoft Date: 1012015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email.FAE@ENGINEER.COM Web:WWW.NORTHFLORIDAAIR,COM Project Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 173 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.0°F Sensible gain: 17931 Btuh Entering coil DB: 76.2°F Outdoor design WB: 78.0°F Latent gain: 2425 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 20356 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A'"30+FX4DNF025 Actual airflow: 800 cfm Sensible capacity: 21971 Btuh 123%of load Latent capacity: 744 Btuh 31%of load Total capacity: 22715 Btuh 112%of load SHR: 97% Heating Equipment Design Conditions Outdoor design DB: 39.0°F Heat loss: 21480 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A"30+FX4DNF025 Actual airflow: 800 cfm Output capacity: 23554 Btuh 110'/o of load Capacity balance: 36 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 5.2 kW 83% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Oct-30 14:41:17 wrightsoft Right-SuiteS?Universal 2015 15.0.17 RSU13554 P 1 A�� ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces: W 1, Residential Plans Examiner Review Form Form ACCK for HVAC System Design (Loads, Equipment. Ducts RPER 1 15 Mar 09 At[:nlrry�yrartm t r rent Header Information Contractor: FLORIDA AIR SERVICE ENGINEERING REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ® No ❑ Mechanical license: CAC1813923 or MJ1AE Form*(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes ❑ No El Building plan#: Manual D Friction Rate Worksheet: Yes ® No El Duct distribution sketch: Yes ® No El Home address(Street or Lot#, Block,Subdivision): 173 OCEAN GATE DR, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building_C_onstruction Information Winter Design Conditions Building Outdoor temperature: 39 °F Orientation: Building Front faces West North,East,West,South,Northeast,Northwest,Southeast.Southwest Indoor temperature: 70 °F Total heat loss: 21480 Btuh Number of bedrooms: 3 Conditioned floor area: 1170 ft° Summer Design Conditions Number of occupants: 0 Outdoor temperature: 92 °F Indoor temperature: 75 °F Windows Grains difference: 58 gr/Ib @50% RH Eave overhang depth: 8.0 ft Sensible heat gain: 17931 Btuh Internal shade: none r.,_ Latent heat gain: 2425 Btuh Blinds,drapes,etc. Total heat gain: 20356 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating FquipmentData Cooling Equipment Data Blower Data Equipment type: Split ASHP Eauioment type: Split ASHP Heating cfm: 800 urnace.Hea pump,Bolter,etc. Airtonditioner,Heat pump,etc. Cooling cfm: 800 Model: Carrier Model: Carrier Static pressure: 0.50 in H2O 25HBC524A""30+FX4DNF025 25HBC524A""30+FX4DNF025 Fan's rated external static pressure for design airltow Heating output capacity: 3554 Btuh Total cooling capacity: 22715 Btuh Heat pumps-capacity at winter design ou our conditions Sensible cooling capacity: 21971 Btuh Aux.heating output capacity: 17762 Btuh Latent cooling capacity: 744 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 800 cfm Longest supply duct: 377 ft Duct Materials Used Equipment design ESP: 0.50 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 377 ft Available static pressure(ASP): 0,50 in H2O Friction rate:1 t f10 in/100ft Branch duct: Round flex vinyl Friction Rate=ASP+(TEL Too) I declare the load calculation.equipment equipment selection and duct design were rigorously performed based on the building uIa• listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: J FERNADNEZ Contractor's signature: J FERNANDEZ(ESIGN) Date: 11/2015 Reserved for County. Town Municipality or Authority having jurisdiction use. "Home qualifies for MJ1AE Form based on Abridged Edition Checklist ± wrightsoft Rig ht-Suite Universal 2015 15.0.17 RSU13554 Load Short Form Job: QUADPLEX-OUTSIDE UNI... wrightsoft Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEgENGINEER.COM Web:WVWV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 173 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Design Information Htg Clg Infiltration Outside db(°F) 39 92 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 31 17 Fireplaces 1 (Average) Daily range - L Inside humidity(%) 40 50 Moisture difference (gr/Ib) 16 58 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC524A**30 Cond 25HBC524A**30 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17718 Btuh Heating output 23554 Btuh @ 47°F Latent cooling 4997 Btuh Temperature rise 27 °F Total cooling 22715 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (f12) (Btuh) (Btuh) (cfm) (cfm) BATH2 96 794 426 30 19 MBED 196 10337 9111 385 406 B E D2 158 2062 1253 77 56 GREAT 249 3160 4301 118 192 MWIC 32 490 94 18 4 BATH1 52 100 130 4 6 MECH 48 501 126 19 6 BED3 151 1996 1204 74 54 KITCHEN 188 2039 1286 76 57 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Oct-30 14:41:18 ti wrightsoft Rig ht-Su ite<F)Universal 2015 15.0.17 RSU13554 Page 1 A ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front laces: W Entire House 1170 21480 17931 800 800 Other equip loads 0 0 Equip. @ 1.00 RSM 17931 Latent cooling 2425 TOTALS I 1170 I 21480 I 20356 I 800 I 800 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Oct-30 14:41:18 , wrightsoft Right-Suite)Universal 2015 15.0.17 RSU13554 Page A ...htsott HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces: W Building Analysis Job: QUADPLEX-0OUTSIDE UNI... wrightsoft Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEiENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 173 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Desi•n Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design 1D (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( I ) Method Simplified Wet bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Heatin• Component Btu h/ft2 Btuh %of load Walls 2.0 1262 5.9 Glazing 48.2 11660 54.3 ---., Doors 0 0 0 Ceilings 1.0 1161 5.4 Floors 1.2 1431 6.7 Infiltration 3.8 3373 15.7 Ducts 2593 12.1 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 21480 100.0 Coolin. Component Btu h/ft2 Btuh % of load Walls 1.2 767 4.3 Glazing 46.6 11289 63.0 Doors 0 0 0 Ceilings 1.7 2035 11.3 .- Floors 0 0 0 Infiltration 0.8 754 4.2 Ducts 3086 17.2 -r Ventilation 0 0 Internal gains 0 0 Blower 0 0 , Adjustments 0 Total 17931 100.0 Latent Cooling Load =2425 Btuh Overall U-value=0.155 Btuh/ft2-°F Data entries checked. 2015-Od-30 14:41:18 wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 P 1 ACCt' ...htsoft HVAC1HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces W •Y• + wri htsoft Project Summary Job: QUADPLEX-OUTSIDE UNI... 9 Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 173 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Notes: Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 %a Moisture difference 58 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18887 Btuh Structure 14845 Btuh Ducts 2593 Btuh Ducts 3086 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21480 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17931 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1596 Btuh Ducts 829 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1170 1170 Equipment latent load 2425 Btuh Volume (ft') 10530 10530 Air changes/hour 0.56 0.23 Equipment total load 20356 Btuh Equiv.AVF (cfm) 99 40 Req. total capacity at 0.78 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC524A**30 Cond 25HBC524A**30 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17718 Btuh Heating output 23554 Btuh @ 47°F Latent cooling 4997 Btuh Temperature rise 27 °F Total cooling 22715 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W rl htsoft 2015-Oct-30 14:41:18 9 Right-SuiteC Universal 2015 15.0.17 RSU13554 Page 1 ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces: W +I+ wrightsoft Loads for Multiple Orientations Job: QUADPLEX-OUTSIDEUNI... Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:VWWV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 173 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD(°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) Vet bulb(°F) - 78 Wind speed (mph) 15.0 7.5 Building Front North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 19163 17105 19695 21522 22224 20052 17931 19836 Latent Load (Btuh) 2425 2425 2425 2425 2425 2425 2425 2425 Total Load(Btuh) 21588 19530 22120 23947 24649 22477 20356 22261 Heating AVF (cfm) 800 800 800 800 800 800 800 800 Cooling AVF (cfm) 800 800 800 800 800 800 800 800 Building Orientation Cooling Load 25000• 2J000 10000 gIn 0 . N NE E g S SN W MN D rEctiai Bild rg Fat fao s Current Orientation: Building Front faces West Highest Cooling Load: Building Front faces South Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-0d-30 14:41:18 t wrightsoft Rig ht-Suitee Universal 2015 15.0.17 RSU13554 Ppst AFtk ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MJ2.rup Calc=MJ8 Building Front faces. W 4 wri htsoft Duct System Summary Job: QUADPLEX-OUTSIDE UNI... 9 Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEO2ENGINEER.COM Web:WVWV.NORTHFLORIDAAIR.COM i Project Information For: QUADPLEX-OUTSIDE UNIT-A, BEACHES HABITAT 173 OCEAN GATE DR, ATLANTIC BEACH, FL 32233 . Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.500 in/100ft 0.500 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 377 ft Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk MECH h 542 28 10 0.500 4.0 Ox 0 VIFx 307.0 70.0 BATH2 h 818 42 30 0.500 4.0 Ox 0 VIFx 307.0 70.0 MBED h 3382 172 147 0.500 7.0 Ox 0 VIFx 307.0 70.0 BED3 h 2297 117 96 0.500 6.0 Ox 0 VIFx 307.0 70.0 KITCHEN h 2343 119 103 0.500 6.0 Ox 0 VIFx 307.0 70.0 BED2 h 2366 120 100 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT c 2148 85 148 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT-A c 2148 85 148 0.500 6.0 Ox 0 VIFx 307.0 70.0 BATH1 c 148 6 10 0.500 4.0 Ox 0 VIFx 307.0 70.0 M1MC h 530 27 7 0.500 4.0 Ox 0 VIFx 307.0 70.0 1 I 1 2015-Oct-3014:43:54 t wrightsoft Right-Suite,Universal 2015 15.0.17 RSU13554 Page CA ..ghtsof HVAC\HABIJAX-QUAD-OUTSIDE UNIT-A-MD.rup Calc=MJ8 Building Front faces W OFFICE COPY 1'77 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-QUADPLEX-INSIDE-B-R-177 Builder Name: BEACHES HABITAT Street: 177 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: I - '- L fi i' T - c)0 yzf Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(1920.0 sqft.) Insulation Area 2. Single family or multiple family Multi-family a. Frame-Wood, Common R=19.0 1392.00 ft' b. Frame-Wood,Exterior R=19.0 528.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (605.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area above grade(ft') 1358 b. N/A R= ft' Conditioned floor area below grade(ft') 0 c. N/A R= ft' 11.Ducts R ft2 7. Windows(105.1 sqft.) Description Area a. Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165 a. U-Factor: Dbl,U=0.30 105.06 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 24.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.049 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (605.0 sqft.) Insulation Area a. Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft' EF:0.920 b. Conservation features b.N/A R= ft' None c. N/A R= ft' 15.Credits Pstat Glass/Floor Area: 0.077 Total Proposed Modified Loads: 25.46 PASS Total Baseline Loads: 26.75 I hereby certify that the plans and specifications covered by Review of the plans and »•O 13E.STAT•`•:•,• this calculation are in compliance with the Florida Energy specifications covered by this 1.,'""i. F •; Code. calculation indicates compliance ' �,.y�'�`•'% °,,-..'"6,,..,': J FERNANDEZ(ESIGN) with the Florida Energy Code. ! ;:u,,;z j.. p•PREPARED BY: Before construction is completed ?� i DATE: __ 11/2015 this building will be inspected for 0 I :a compliance with Section 553.908 : `. p t I hereby certify that this building, as designed, is in compliance Florida Statutes. 4... .y. :4S I` with the Florida Energy ode-" •••.COd v,, OWNER/AGENT: ' 4d • - ,� _. BUILDING OFFICIAL: DATE: // - %/ - /) DATE: , - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance requires a roof emittance test in accordance with R405.7.2 11/4/2015 3:13 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: HABITAT-QUADPLEX-INSID Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1358 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 270 Street: 177 OCEAN GATE DRI Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 1358 10864 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 805 6440 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 553 4424 No 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge lnsulatio 1st Floor 190 ft 605 ft2 ---- 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 638 ft2 100 ft2 Medium 0.75 No 0.9 Yes 0 18.4 V ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 605 ft2 N N CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 605 ft2 0 Wood 11/4/2015 3:13 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below !t Clrnt Tn W211 Typo Space R-VaIua Ft In Ft In Aran R-Vahia Frartinn Ahcnr (.rada°L, 1 N=>W Exterior Frame-Wood 1st Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 2 E=>N Neighbor Frame-Wood 1st Floor 19 52 0 8 416.0 ft2 0.23 0.75 0 3 S=>E Exterior Frame-Wood 1st Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 4 W=>S Neighbor Frame-Wood 1st Floor 19 52 0 8 416.0 ft2 0.23 0.75 0 - 5 N=>W Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 6 E=>N Neighbor Frame-Wood 2nd Floor 19 35 0 8 280.0 ft2 0.23 0.75 0 7 S=>E Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 _ 8 W=>S Neighbor Frame Wood 2nd Floor 19 35 0 8 280.0 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated 1st Floor Metal .46 3 6 8 20 ft2 2 S=>E Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 S=>E 3 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 4 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed CFM(50) .1 .00 .01 .0000 .0003 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 24 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 24 kBtu/hr 720 cfm 0.75 1 sys#1 11/4/2015 3:13 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply--- --Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling X Jan X Feb X Mar X Apr X May X Jun rxi Jul X'Aug X Sep X Oct X Nov X Dec Heatinngg �XJ Jan X�Feb X�Mar [X�Apr �X�May f X�Jun Jul X Aug [X�Sepp [X�Oct X�Nov f X�Dec Venti X Jan X Feb X Mar [X A r X Ma X Jun Jul X'Aug [X Sep [X Oct X Nov X Dec• Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 11/4/2015 3:13 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD 1 ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index,the more efficient the home. 177 OCEAN GATE DRIVE, ATLANTIC BEACH , FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Common R=19.0 1392.00 ft2 b.Frame-Wood,Exterior R=19.0 528.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? 10.Ceiling Types Insulation Area No a.Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area(ft2) 1358 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.30 105.06 ft2 11.Ducts R ft2 a.Sup:1st Floor,Ret: 1st Floor,AH:Attic 6 165 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 24.0 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 24.0 HSPF:8.50 Area Weighted Average Overhang Depth: 3.049 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems ft2 a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft EF:0.92 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building .•••"-NEST ......... .9r Construction through the above energy saving features which will be installed (or exceeded) .yO �; 1 `F in this home before final inspection. Otherwise,a new EPL Display Card will be completed yam:;; %.. 'i t ..4.,.;\r.based on installed Code compliant features. ' '. ,,.0 Builder Signature: Date: J.1.;. . _on--yp 1a Address of New Home: /77 D, 44.E City/FL Zip: ,nom/ , ge `�`•.-4;" . ct. `, C.D -32_2_33 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/4/2015 3:14 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Florida Code 2014 Summary Report Title: HABITAT-QUADPLEX-INSIDE-B-R-177 TMY City: FL_JACKSONVILLE_ 177 OCEAN GATE DRIVE FLProp2014 Elec Util: Florida Average ATLANTIC BEACH , FL, 32233 Gas Util: Florida Average Registration#: Run Date: Energy Uses Reference Home Proposed Home e-Ratio Heating 1.58 MBtu 0.69 MBtu 0.44 Cooling 4.76 MBtu 4.79 MBtu 1.01 Hot Water 8.58 MBtu 8.94 MBtu 1.04 Total 14.92 MBtu 14.42 MBtu 0.97 Building Loads Reference Home Proposed Home e-Ratio Heating 3.09 MBtu 1.35 MBtu* 0.44 Cooling 15.25 MBtu 15.35 MBtu* 1.01 Hot Water 8.41 MBtu 8.76 MBtu* 1.04 Total 26.75 MBtu 25.46 MBtu 0.95 *normalized modified loads Glass/Floor Area: 0.077 Total Proposed Modified Loads: 25.46 PASS Total Reference Loads: 26.75 11/4/2015 3:14 PM EnergyGaugee USA-FlaRes2014/ Page 1 of 1 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-QUADPLEX-INSIDE-B-R-177 Builder Name: BEACHES HABITAT Street: 177 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow Cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/4/2015 3:15 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 177 OCEAN GATE DRIVE Permit Number: ATLANTIC BEACH ,FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. xi 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. 0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust.intake,makeup air,backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures: 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6. Supply and return registers,if installed at the time of the test,shall be fully open. c R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. C: R402.4.3 Fenestration air IeakageWrndows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows.skylights and doors. 0 R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. 6 R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. X R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that.except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. El R403.2.2 Sealing(MandatoryAll ducts,air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41`C) or below 55°F(13°C)shall be insulated to a minimum of R-3., G R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight,moisture,equipment maintenance.and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. El R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies 0 R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100`F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. c R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code, Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. G R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. 1 c R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19.space permitting,or R-10 otherwise. KJ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. G R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) C R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal. rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data. the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units.the capacity of equipment may be sized in accordance with good design practice. n R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ▪ R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. C R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. o R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. C R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas- and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16.2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2, Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. C: R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. o R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 Manual S Compliance Report Job: QUADPLEX-INSIDE UNIT-B wrightsoft Date: 1112015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-INSIDE UNIT-B, BEACHES HABITAT 177 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.0°F Sensible gain: 19218 Btuh Entering coil DB: 76.3°F Outdoor design WB: 78.0°F Latent gain: 2756 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 21974 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A"030+FX4DNF025 Actual airflow: 800 cfm Sensible capacity: 17901 Btuh 93%of load Latent capacity: 4802 Btuh 174%of load Total capacity: 22703 Btuh 103%of load SHR: 79% Heating Equipment Design Conditions Outdoor design DB: 39.0°F Heat loss: 21676 Btuh Entering coil DB: 69.4°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A*030+FX4DNF025 Actual airflow: 800 cfm Output capacity: 22220 Btuh 103%of load Capacity balance: 36 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 5.2 kW 82%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. wrightsoft ht50Th 2015-Nov-0410:16:37 9 Rig Universal2015 15.0.17 RSU13554 Page 1 ...ghtsott HVAC\HABIJAX-QUAD-INSIDE UNIT-B-MJ3.rup Calc=MJ8 Building Front faces W ,.w � Residential Plans Examiner Review Form Form CK. for HVAC System Design (Loads, Equipment. Ducts RPER 1 15 Mar 09 At rmillmn9(. tn,rth,.. Header Information Contractor: FLORIDA AIR SERVICE&ENGINEERING REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes No ❑ Mechanical license: CAC1813923 or MJ1AE Form`(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes ❑ No ❑ Building plan#. Manual D Friction Rate Worksheet: Yes ® No ❑ i Duct distribution sketch: Yes ® No ❑ Home address(Street or Lot#,Block,Subdivision): 177 OCEAN GATE DR, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Desi.gn_Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 39 °F Orienttion: Building Front faces West Indoor temperature: 70 °F North,East.West.South,Northeast,Northwest.Southeast.Southwest Total heat loss: 21676 Btuh Number of bedrooms: 3 Conditioned floor area: 1358 ft' Summer Design Conditions Number of occupants: 0 Outdoor temperature: 92 °F Indoor temperature: 75 °F Windows Grains difference: 58 gr/Ib @50% RH Eave overhang depth: 8.0 ft Sensible heat gain: 19218 Btuh Internal shade: none E: Latent heat gain: 2756 Btuh Blinds,drapes,etc. Dept?, ',1 rn::,. Total heat gain: 21 974 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Faitipment Data Cooling Fauipment Data Blower Data Equipment type: Split ASHP ElYiTment type: Split ASHP Heating cfm: 800 urnace,Hea pump,Boller,etc. tr ondttione,Heat pump,etc. Cooling cfm: 800 Model: Carrier Model: Carrier Static pressure: 0.50 in H2O 25HBC524A'030+FX4DNF025 25HBC524A*030+FX4DNF025 Fan's rated external static pressure for design airflow Heating output capacity: 2220 .Btuh Total cooling capacity: 22703 Btuh Heat pumps-capacity at winter design ou oor conditions Sensible cooling capacity: 17901 Btuh Aux.heating output capacity: 17762 Btuh Latent cooling capacity: 4802 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 800 cfm Longest supply duct: 377 ft Duct Materials Used Equipment design ESP: 0.50 in H2O Longest return duct: 0 ft Trunk duct Total device pressure losses: 0 in H2O Total effective length(TEL): 377 ft Available static pressure(ASP): 0.50 in H2O Friction rate: �,5flp in/100ft Branch duct: Round flex vinyl Friction Rate=ASP+(TEL too)) I declare the load calculation. equipment. equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: J FERNANDEZ Contractor's signature: J FERNANDEZ(ESIGN) Date: 11/2015 Reserved for County. Town Municipality or Authority having jurisdiction use. 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist -F}+ wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 +If wrightsoft Load Short Form Job: QUADPLEX-INSIDE UNIT-B Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:WWVJ.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-INSIDE UNIT- B, BEACHES HABITAT 177 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Design Information Htg Clg Infiltration Outside db (°F) 39 92 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 31 17 Fireplaces 1 (Average) Daily range - L Inside humidity(%) 40 50 Moisture difference(gr/Ib) 16 58 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A*030 Cond 25HBC524A*030 AHRI ref 7914088 Coil FX4DNF025 AHRI ref 7914088 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17708 Btuh Heating output 22220 Btuh @ 47°F Latent cooling 4995 Btuh Temperature rise 25 °F Total cooling 22703 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft) (Btuh) (Btuh) (cfm) (cfm) BATH2 88 407 197 15 8 BED2 216 2014 1160 74 48 GREAT 276 3220 4379 119 182 BATH1 98 2055 1183 76 49 MECH 66 531 168 20 7 BED3 202 2116 1335 78 56 KITCHEN 198 2111 1326 78 55 BED1 214 9222 9470 340 394 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft I"ltSOt� 2015-Nov-0410:16:37 t 9 Right-Suite®Universal 2015 15.0.17 RSU13554 Page l oak ...ghtsoft HVAC1HABIJAX-QUAD-INSIDE UNIT-B-MJ3.rup Calc°MJ8 Building Front faces: W Entire House 1358 21676 19218 800 800 Other equip loads 0 0 Equip. @ 1.00 RSM 19218 Latent cooling 2756 TOTALS 1 1358 I 21676 I 21974 I 800 I 800 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2015-Nov-0410:16:37 t 9 Rig Universal 2015 15.0.17 RSU13554 Page 2 lak ...ghtsoft HVAC\HABIJAX-QUAD-INSIDE UNIT-B-MJ3.rup Calc=MJ8 Building Front faces. W 41- Building Analysis Job: QUADPLEX-INSIDE UNIT-B wrightsoft Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone.904-823-9696 Email:FAECENGINEER.COM Web:WVWV.NORTHFLORIDAAIR.COM Pro'ect Information For: QUADPLEX-INSIDE UNIT-B, BEACHES HABITAT 177 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Desi•n Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( I ) Method Simplified \A t bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Heatin• Component Btu hilt' Btuh %of load Walls 2.7 2415 11.1 Glazing 47.1 10230 47.2 Doors 0 0 0 Ceilings 1.0 1347 6.2 _ _. Floors 0.8 1095 5.0 Infiltration 3.4 3806 17.6 Ducts 2784 12.8 Piping 0 0 Humidification 0 0 Ventilation 0 0 `" Adjustments 0 Total 21676 100.0 Coolin• • Component Btu Mt' Btuh %of load ...iii Walls 1.4 1274 6.6 Glazing 52.2 11325 58.9 Doors 0 0 0 Ceilings 1.7 2362 12.3 Floors 0 0 0 Infiltration 0.8 876 4.6 Ducts 3382 17.6 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 19218 100.0 Latent Cooling Load =2756 Btuh Overall U-value =0.127 Btuh/ft2-°F Data entries checked. L wrightsoft 2015-Nov-0410:16:37 Right-Suitet Universal 2015 15.0.17 RSU13554 Page 1 ACCP. ...ghtsoft HVAC\HABIJAX-QUAD-INSIDE UNIT-B-MJ3.rup Calc=MJ8 Building Front faces W Project Summary Job: QUADPLEX-INSIDE UNIT-B wrightsoft Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEcENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-INSIDE UNIT- B, BEACHES HABITAT 177 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Notes: Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 58 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18892 Btuh Structure 15837 Btuh Ducts 2784 Btuh Ducts 3382 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21676 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19218 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1852 Btuh Ducts 904 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 1358 1358 Equipment latent load 2756 Btuh Volume (ft') 12222 12222 Air changes/hour 0.55 0.23 Equipment total load 21974 Btuh Equiv.AVF (cfm) 112 47 Req.total capacity at 0.78 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A*030 Cond 25HBC524A'030 AHRI ref 7914088 Coil FX4DNF025 AHRI ref 7914088 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17708 Btuh Heating output 22220 Btuh @ 47°F Latent cooling 4995 Btuh Temperature rise 25 °F Total cooling 22703 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. . 4* W f I fltsoft 2015-Nov-04 10:16:37 � g Right-Su 2015 15.0.17 RSU13554 Page 1 A77(:--A- ...ghtsoft FIVAC\HABIJAX-QUAD-INSIDE UNIT-B-MJ3.rup Calc=MJ8 Building Front faces W +3+- wrightsoft Loads for Multiple Orientations Job: QUADPLEX-INSIDE UNIT-B 9 Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE.FL 32081 Phone:904-823-9696 Email:FAE©ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM 1 Project Information For: QUADPLEX-INSIDE UNIT-B, BEACHES HABITAT 177 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference(grub) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Dailyrange (°F) - 15 ( L ) Wet bulb(°F) - 78 Wind speed(mph) 15.0 7.5 Building Front North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 18863 18758 21670 22109 21040 20150 19218 20252 Latent Load (Btuh) 2756 2756 2756 2756 2756 2756 2756 2756 Total Load(Btuh) 21620 21515 24426 24866 23796 22906 21974 23008 Heating AVF (cfm) 800 800 800 800 800 800 800 800 Cooling AVF (cfm) 800 800 800 800 800 800 800 800 Building Orientation Cooling Load .:m 1-HI of 0 N NE E g S SN W ❑reclim Bildrp Fr al fa3ts Current Orientation: Building Front faces West Highest Cooling Load: Building Front faces Southeast Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2015-Nov-0410:16:37 g Right-Suite�Universa1201515.0.17 ROW 3554 Page 1 ...ghtsoft HVACIHABIJAX-QUAD-INSIDE UNIT-B-MJ3.rup Cale=MJ8 Building Front faces. W +i+ wrightsoft Duct System Summary Job: QUADPLEX-INSIDE UNIT-C Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEtENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-INSIDE UNIT-B, BEACHES HABITAT 177 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.500 in/100ft 0.500 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 377 ft Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk MECH h 580 31 14 0.500 4.0 Ox 0 VIFx 307.0 70.0 BATH2 h 863 46 34 0.500 4.0 Ox 0 VIFx 307.0 70.0 BED3 h 2522 135 114 0.500 6.0 Ox 0 VIFx 307.0 70.0 KITCHEN h 2507 134 112 0.500 6.0 Ox 0 VIFx 307.0 70.0 BED2 h 2576 138 116 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT-A c 2199 94 154 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT c 2199 94 154 0.500 6.0 Ox 0 VIFx 307.0 70.0 BATH1 h 2405 129 101 0.500 6.0 Ox 0 VIFx 307.0 70.0 2015-Oct-30 16:01:56 ^.`�c' wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 ...ightsoft HVACIHABIJAX-QUAD-INSIDE UNIT-B-MD.rup Calc=MJ8 Building Front faces: W OFFICE COPY 1 I FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-QUADPLEX-INSIDE-C-S-181 Builder Name: BEACHES HABITAT Street: 181 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: /S-SM/ -- �S' Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(1920.0 sqft.) Insulation Area 2. Single family or multiple family Multi-family a. Frame-Wood,Common R=19.0 1392.00 ft' b.Frame-Wood,Exterior R=19.0 528.00 ft' 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types (605.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 605.00 ft' 6. Conditioned floor area above grade(ft') 1358 b. N/A R= ft2 Conditioned floor area below grade(ft') 0 c. N/A R= ft' 11.Ducts R ft' 7. Windows(105.1 sqft.) Description Area a. Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165 a. U-Factor: Dbl,U=0.30 105.06 ft' SHGC: SHGC=0.30 b. U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 22.7 SEER:15.25 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 22.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.049 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems a. Electric Cap:40 gallons 8. Floor Types (605.0 sqft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft' b. Conservation features b.N/A R= ft2 None c.N/A R= ft' 15.Credits Pstat Glass/Floor Area: 0.077 Total Proposed Modified Loads: 25.23 PASS Total Baseline Loads: 26.75 I hereby certify that the plans and specifications covered by Review of the plans and :;.••.i/HE Stn....; this calculation are in compliance with the Florida Energy specifications covered by this b. .............. •- .• er•;: Code. calculation indicates compliance 'y "1(°`• •• ` ,`._.s+s J FERNANDEZ(ESIGN) with the Florida Energy Code. • %m„ '•; "=€P4...,.., .„\0 PREPARED BY: Before construction is completed .�'10"•_ DATE: 11/0215 this building will be inspected for 4: 1)• ... ,`a compliance with Section 553.908 ■ * I hereby certify that this building, as designed, is in compliance Florida Statutes. °� : ,S with the Florida Energy Code. OD IS...... OWNER/AGENT: BUILDING OFFICIAL: DATE: !___t.1 i) DATE: / '7' i 5• - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 10/30/2015 4:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: HABITAT-QUADPLEX-INSID Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1358 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 270 Street: 181 OCEAN GATE DRI Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH • Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL JACKSONVILLE INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block/ 1358 10864 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 1st Floor 805 6440 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 553 4424 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 605 ft2 --__ 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 638 ft2 100 ft2 Medium 0.75 No 0.9 No 0 18.4 V ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 605 ft2 N N CEILING ✓ # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 605 ft2 0 Wood 10/30/2015 4:32 PM EnergyGauge8 USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS V Adjacent Cavity Width Height Sheathing Framing Solar Below It Ornt To Wall Typo Space R-valuo Ft In Ft In ArP.a. R Valuo Frartion Absor Grado°4 _ 1 N=>W Exterior Frame-Wood 1st Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 _ 2 W=>S Neighbor Frame-Wood 1st Floor 19 52 0 8 416.0 ft2 0.23 0.75 0 3 S=>E Exterior Frame-Wood 1st Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 4 E=>N Neighbor Frame-Wood 1st Floor 19 52 0 8 416.0 ft2 0.23 0.75 0 5 N=>W Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 _ 6 W=>S Neighbor Frame-Wood 2nd Floor 19 35 0 8 280.0 ft2 0.23 0.75 0 7 S=>E Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 8 E=>N Neighbor Frame-Wood 2nd Floor 19 35 0 8 280.0 ft2 0.23 0.75 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated 1st Floor Metal .46 3 6 8 20 ft2 2 S=>E Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(_>)changed to As Built(rotated 270 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 S=>E 3 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 4 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 It 0 in 1 ft 0 in Drapes/blinds None 6 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed CFM(50) .1 .00 .01 .0000 .0003 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 22.2 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15.2522.7 kBtu/hr 681 cfm 0.75 1 sys#1 10/30/2015 4:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 HOT WATER SYSTEM ✓ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply-- —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Venting XI Jan [X�Feb XI Mar [Xl Apr Xi May �X�Jun X1 Jul XI Aug �X�Sep �Xi Oct iXxl Nov �Xi Dec Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 10/30/2015 4:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 181 OCEAN GATE DRIVE, ATLANTIC BEACH , FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a. Frame-Wood, Common R=19.0 1392.00 ft b. Frame-Wood, Exterior R=19.0 528.00 ft 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types Insulation Area a. Under Attic(Vented) R=30.0 605.00 ft 6. Conditioned floor area(ft2) 1358 b. N/A R= ft' 7. Windows" Description Area c. N/A R= ft'' a. U-Factor: Dbl,U=0.30 105.06 ft' 11.Ducts R ft a. Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165 SHGC: SHGC=0.30 b. U-Factor: N/A ft' SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a.Central Unit 22.7 SEER:15.25 SHGC: d. U-Factor: N/A ft' 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 22.2 HSPF:8.50 Area Weighted Average Overhang Depth: 3.049 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a. Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft EF:0.92 b.N/A R= ft' c. N/A R= ft' b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ...*foe ST,gj;'••... Construction through the above energy saving features which will be installed (or exceeded) .._,,v,..;.:. in this home before final inspection. Otherwise, a new EPL Display Card will be completed 4t/.;;;;'1 `.; based on installed Code compliant features. : `li�„l S Builder Signature: --C' _1, ,✓ Date: //- /(- / 5- Le_ . a Address of New Home: ICI ©e�. L„/.L `;-� City/FL Zip: ./�----ri ,bZ gC„-.." '....,^.....-7Y 5� . . . ', 3 OD .". *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/30/2015 4:22 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Florida Code 2014 Summary Report Title: HABITAT-QUADPLEX-INSIDE-C2 TMY City: FL_JACKSONVILLE_ 181 OCEAN GATE DRIVE FLProp2014 Elec Util: Florida Average ATLANTIC BEACH , FL, 32233 Gas Util: Florida Average Registration#: Run Date: Energy Uses Reference Home Proposed Home _ e-Ratio Heating 1.58 MBtu 0.69 MBtu 0.44 Cooling 4.76 MBtu 4.72 MBtu 0.99 Hot Water 8.58 MBtu 8.94 MBtu 1.04 Total 14.92 MBtu 14.35 MBtu 0.96 Building Loads Reference Home Proposed Home e-Ratio Heating 3.09 MBtu 1.35 MBtu* 0.44 Cooling 15.25 MBtu 15.12 MBtu* 0.99 Hot Water 8.41 MBtu 8.76 MBtu* 1.04 Total 26.75 MBtu 25.23 MBtu 0.94 * normalized modified loads Glass/Floor Area: 0.077 Total Proposed Modified Loads: 25.23 PASS Total Reference Loads: 26.75 10/30/2015 4:22 PM EnergyGauge®USA-FlaRes2014/ Page 1 of 1 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-QUADPLEX-INSIDE-C2 Builder Name: BEACHES HABITAT Street: 181 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City, State,Zip: ATLANTIC BEACH . FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/30/2015 4:22 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods I ADDRESS: 181 OCEAN GATE DRIVE Permit Number ATLANTIC BEACH ,FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. to 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085. Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. & R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. c R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust.intake, makeup air, backdraft and flue dampers shall be closed.but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open: 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed: 5.Heating and cooling systems,if installed at the time of the test.shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. o R402.4.2 Fireplaces.New wood-burning fireplaces shall have light-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2).and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMANVDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. o R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. It R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. KI R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. KI R403.2.2 Sealing(Mandatory)Jl ducts.air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system.including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test.total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. C R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. O R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., C R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind.and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. )i R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies C R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100`F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806.Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal:and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. C R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawtspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. KI R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. C R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. C R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. • R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. o R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 55"F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40`F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. G R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2.Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. 0 R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy, such as a heat pump or solar energy source computed over an operating season. RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. C R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 10/9/2015 8:35 AM EnergyGaugee USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 Manual S Compliance Report Job: QUADPLEX-INSIDE UNIT-C wrightsoft Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE.FL 32081 Phone:904-823-9696 Email:FAEcENGINEER.COM Web:WWVV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-INSIDE UNIT-C, BEACHES HABITAT 181 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.0°F Sensible gain: 19210 Btuh Entering coil DB: 76.3°F Outdoor design WB: 78.0°F Latent gain: 2756 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 21967 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A*030+FX4DNF025 Actual airflow: 800 cfm Sensible capacity: 17901 Btuh 93% of load Latent capacity: 4802 Btuh 174%of load Total capacity: 22703 Btuh 103%of load SHR: 79% Heating Equipment Design Conditions Outdoor design DB: 39.0°F Heat loss: 21662 Btuh Entering coil DB: 69.4°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A*030+FX4DNF025 Actual airflow: 800 cfm Output capacity: 22220 Btuh 103%of load Capacity balance: 36 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 5.2 kW 82% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 201 5-Nov-0410:17:33 wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Pagel ...ightsoft HVACWABIJAX-QUAD-INSIDE UNIT-C-MJ.nrp Calc=MJ8 Building Front faces: W Residential Plans Examiner Review Form Form ACCA. for HVAC System Design (Loads, Equipment, Ducts RPER 1 15 Mar 09 Ar Cerrinoi∎Glttalm,N!ever.: Header Information Contractor: FLORIDA AIR SERVICE&ENGINEERING REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes in No ❑ Mechanical license: CAC1813923 or MJ1AE Form'(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes ❑ No ❑ Building plan#: Manual D Friction Rate Worksheet: Yes [Z] No ❑ Duct distribution sketch: Yes ® No ❑ Home address(Street or Lot#.Block,Subdivision): 181 OCEAN GATE DR, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 39 °F Orientation: Building Front faces West Indoor temperature: 70 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 21662 Btuh Number of bedrooms: 3 Conditioned floor area: 1358 ft' Summer Design Conditions Number of occupants: 0 Outdoor temperature: 92 °F Indoor temperature: 75 °F Windows Rte. Grains difference: 58 gr/Ib @50% RH Eave overhang depth: 8.0 ft Sensible heat gain: 19210 Btuh Internal shade: none • B Enve linds,drapes,etc. Dept Latent heat gain: 2756 Btuh Depth wtna.,, Total heat gain: 21967 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating_Equipment Data Cooling Fquipment Data Blower Data Equipment type: Split ASHP EaAuiTment type: Split ASHP Heating cfm: 800 umace,Hea pump,Boller,etc. Ir ondltlone,Heat pump,etc. Cooling cfm: 800 Model: Carrier Model: Carrier Static pressure: 0.50 in H2O 25HBC524A'030+FX4DNF025 25HBC524A'030+FX4DNF025 Fan's rated external static pressure for design airflow Heating output capacity: 2220 Btuh Total cooling capacity: 22703 Btuh Heat pumps-capac ty at winter design ou oor conditions Sensible cooling capacity: 17901 Btuh Aux.heating output capacity: 17762 Btuh Latent cooling capacity: 4802 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 800 cfm Longest supply duct: 377 ft Duct Materials Used Equipment design ESP: 0.50 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 377 ft Available static pressure(ASP): 0.50 in H2O Friction rate: - 0 in/100ft Branch duct: Round flex vinyl Friction Rate=ASP+(TEL tml I declare the load calculation.equipment equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: J FERNANDEZ Contractor's signature: J FERNANDEZ(ESIGN) Date: 11/2015 Reserved for County. Town Municipality or Authority having jurisdiction use. 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist ± wrightsoft Rig hi-Suttee Universal 2015 15.0.17 RSU13554 wrightsoft Load Short Form Job: QUADPLEX-INSIDE UNIT-C 9 Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:VWWV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-INSIDE UNIT-C, BEACHES HABITAT 181 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Design Information Htg Clg Infiltration Outside db(°F) 39 92 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 31 17 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 40 50 Moisture difference (gr/Ib) 16 58 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A*030 Cond 25HBC524A*030 AHRI ref 7914088 Coil FX4DNF025 AHRI ref 7914088 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17708 Btuh Heating output 22220 Btuh @ 47°F Latent cooling 4995 Btuh Temperature rise 25 °F Total cooling 22703 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) BATH2 88 407 197 15 8 BED2 216 1982 1147 73 48 GREAT 276 3223 4380 119 182 BATH1 98 2058 1184 76 49 M EC H 66 531 168 20 7 BED3 202 2119 1336 78 56 KITCHEN 198 2114 1327 78 55 BED1 214 9228 9472 341 394 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Nov-04 10:17:33 wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 I ...ightsoft HVACWABIJAX-QUAD-INSIDE UNIT-C-MJ.rup Calc=MJ8 Building Front faces. W Entire House 1358 21662 19210 800 800 Other equip loads 0 0 Equip. @ 1.00 RSM 19210 Latent cooling 2756 TOTALS I 1358 I 21662 I 21967 I 800 I 800 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Nov-04 10:17:33 ti�+ wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 2 / ...ightsoft HVAC\HABIJAX-QUAD-INSIDE UNIT-C-MJ.rup Calc=MJ8 Building Front faces: W Building Analysis Job: QUADPLEX-INSIDE UNIT-C wrightsoft Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAECENGINEER.COM Web:VVvWV.NORTHFLORIDAAIR.COM Pro'ect Information For: QUADPLEX-INSIDE UNIT-C, BEACHES HABITAT 181 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Desi•n Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( I ) Method Simplified V\kt bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Heatin• Component Btuh/ft2 Btuh % of load Walls 2.7 2402 11.1 Glazing 47.1 10230 47.2 Doors 0 0 0 Ceilings 1.0 1347 6.2 Floors 0.8 1095 5.1 Infiltration 3.4 3806 17.6 Ducts 2783 12.8 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 21662 100.0 Coolin. Component Btu h/ft2 Btuh %of load Walls 1.4 1267 6.6 Glazing 52.2 11325 59.0 Doors 0 0 0 Ceilings 1.7 2362 12.3 Floors 0 0 0 Infiltration 0.8 876 4.6 Ducts 3381 17.6 Ventilation 0 0 Internal gains 0 0 j Blower 0 0 Adjustments 0 Total 19210 100.0 Latent Cooling Load =2756 Btuh Overall U-Value =0.127 Btuh/ft2-°F Data entries checked. 2015-Nov-04 10 17:33 wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 ACC*. ...ightsoft HVAC\HABIJAX-QUAD-INSIDE UNIT-C-MJ.rup Calc=MJ8 Building Front faces: W Project Summary Job: QUADPLEX-INSIDE UNIT-C wrightsoft Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:VVWW.NORTHFLORIDAAIR.COM Pro"ect Information For: QUADPLEX-INSIDE UNIT-C, BEACHES HABITAT 181 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Notes: Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 58 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18879 Btuh Structure 15830 Btuh Ducts 2783 Btuh Ducts 3381 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21662 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19210 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1852 Btuh Ducts 904 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 1358 1358 Equipment latent load 2756 Btuh Volume (ft') 12222 12222 Air changes/hour 0.55 0.23 Equipment total load 21967 Btuh Equiv. AVF (cfm) 112 47 Req. total capacity at 0.78 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A*030 Cond 25HBC524A*030 AHRI ref 7914088 Coil FX4DNF025 AHRI ref 7914088 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17708 Btuh Heating output 22220 Btuh @ 47°F Latent cooling 4995 Btuh Temperature rise 25 °F Total cooling 22703 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + wrightsoft 2015-Nov-0410:17:33 a Q Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 A ...ightsoft HVACWABIJAX-QUAD-INSIDE UNIT-C-MJ.rup Calc=MJ8 Building Front faces: W +I+ wrightsoft Loads for Multiple Orientations Job: QUADPLEX-INSIDE UNIT-C Date: 11!2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEIXENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM i Project Information For: QUADPLEX-INSIDE UNIT-C, BEACHES HABITAT 181 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference(grub) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) V■kt bulb(°F) - 78 Wind speed(mph) 15.0 7.5 Building Front North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 18856 18751 21662 22102 21033 20142 19210 20244 Latent Load(Btuh) 2756 2756 2756 2756 2756 2756 2756 2756 Total Load(Btuh) 21612 21507 24418 24858 23789 22899 21967 23001 Heating AVF (cfm) 800 800 800 800 800 800 800 800 Cooling AVF (cfm) 800 800 800 800 800 800 800 800 Building Orientation Cooling Load 2900 0 . N NE E g S SN W WV Drum BiIdrg Rort faes Current Orientation: Building Front faces West Highest Cooling Load: Building Front faces Southeast Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .` 'fief Wf 1 htsoft 2015-Nov-04 10:17:33 9 Right-Suite6 Universal 15.0.17 RSU13554 Page 1 AM ...ightsofl HVAC\HABIJAX-QUAD-INSIDE UNIT-C-MJ.rup Calc=MJ8 Building Front laces. W 4 Duct System Summary Job: QUADPLEX-INSIDE UNIT.C wrightsoft Date: 11/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEGENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-INSIDE UNIT-C, BEACHES HABITAT 181 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.500 in/100ft 0.500 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 377 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk MECH h 580 31 14 0.500 4.0 Ox 0 VIFx 307.0 70.0 BATH2 h 863 46 34 0.500 4.0 Ox 0 VIFx 307.0 70.0 BEDS h 2522 135 114 0.500 6.0 Ox 0 VIFx 307.0 70.0 KITCHEN h 2507 134 112 0.500 6.0 Ox 0 VIFx 307.0 70.0 BED2 h 2576 138 116 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT-A c 2199 94 154 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT c 2199 94 154 0.500 6.0 Ox 0 VIFx 307.0 70.0 BATH1 h 2405 129 101 0.500 6.0 Ox 0 VIFx 307.0 70.0 2015-Oct-30 16:01:56 wrightsoft Rig ht-Su iteGUniver sal 2015 15.0.17 RSU13554 Pagel AM ...ightsoft HVAC\HABIJAX-QUAD-INSIDE UNIT-C-MD.rup Calc=MJ8 Building Front faces: W OFFICE COPY 18 r,._--.) FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-QUADPLEX-OUTSIDE-D-R-185 Builder Name: BEACHES HABITAT Street: 185 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY r)r)yw j City, State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number:/1"S /� / p( Owner Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(1637.3 sqft.) Insulation Area a. Frame Wood,Exterior R=19.0 1138.70 ft' 2. Single family or multiple family Multi-family b.Frame-Wood,Common R=19.0 498.67 ft' 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft' 10.Ceiling Types (605.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area above grade(ft') 1170 b. N/A R= ft' c. N/A R= ft' Conditioned floor area below grade(ft') 0 11.Ducts R ft2 7. Windows(130.0 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165 a. U-Factor. Dbl,U=0.30 130.00 ft' SHGC: SHGC=0.30 b. U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency a.Central Unit 22.7 SEER:15.00 SHGC: c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 23.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a.Electric Cap:40 gallons 8. Floor Types (605.0 sqft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft' b. Conservation features b. N/A R= ft2 None c. N/A R= ft' 15.Credits Pstat Total Proposed Modified Loads: 27.52 PASS Glass/Floor Area: 0.111 Total Baseline Loads: 31.69 I hereby certify that the plans and specifications covered by Review of the plans and :�o••Ira srgT�'•'ti•• this calculation are in compliance with the Florida Energy specifications covered by this .j• v. ' _ ,:.:0,,, Code. calculation indicates compliance :'y %o, °'• :',,.0•'°'{'•.. J FERNANDEZ(ESIGN) with the Florida Energy Code. i . PREPARED BY: Before construction is completed '• IL-_= '-.::°t" - >; DATE: 11/2015 this building will be inspected for `•. ' e- ?a c compliance with Section 553.908 }.*"a - I hereby certify that this building, as designed, is in compliance Florida Statutes. ! •SS,,, .,.fc00 •-O with the Florida Energy Co e. WE • '•o• OWNER/AGENT: BUILDING OFFICIAL: DATE: j/ - I I - / ) DATE: 1 i- ` ' ./ Y - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 11/4/2015 3:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: HABITAT-QUADPLEX-OUTSI Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1170 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 270 Street: 185 OCEAN GATE DRI Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 1170 9360 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 565 4520 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 605 4840 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 605 ft2 _-- 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 638 ft2 100 ft2 Medium 0.85 No 0.9 No 0 18.4 V ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 605 ft2 N N CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 605 ft2 0 Wood 11/4/2015 3:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it (lrnf Tn Wall Tyra Space R_Valua Ft In Ft In Aran R_Valua Frartinn Ahcnr C;rarla°/ 1 N=>W Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 2 E=>N Exterior Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 3 S=>E Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 4 W=>S Neighbor Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 5 N=>W Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 6 E=>N Exterior Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 7 S=>E Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 8 W=>S Neighbor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated 1st Floor Metal .46 3 6 8 20 ft2 2 S=>E Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 6 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 7 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed CFM(50) .1 .00 .01 .0000 .0003 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 23.5 kBtu/hr 1 sys#1 11/4/2015 3:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 22.7 kBlu/hr 681 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS / --Supply--- --Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [X]]Jan X]Feb X Mar [X]A r [[X]]Ma [[X]]Jun [Xj Jul ((X]]Au [[X�]]Se [[X]]Oct [[X]Nov ((X Dec Heating iX]Jan X)Feb 7C]Mar iX]Ar, [X]May [X]Jun [X)Jul [X]Aug [X]Sep [X]Oct [X]Nov iX Dec Venting X Jan X Feb X Mar [X]Apr [X May [[X]l Jun [X]Jul [[X]]Aug [[XX]]Sep [[X]]Oct [[X]Nov [[X Dec Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) PM 72 72 72 72 72 72 72 72 72 72 72 72 0 11 I 11/4/2015 3:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. 185 OCEAN GATE DRIVE, ATLANTIC BEACH , FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 ft2 b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area(ft2) 1170 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.30 130.00 ft2 11.Ducts R ft2 SHGC: SHGC=0.30 a.Sup: 1st Floor,Ret: 1st Floor,AK Attic 6 165 b. U-Factor. N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 22.7 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.252 ft. a.Electric Heat Pump 23.5 HSPF:8.50 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 a.Electric Cap:40 gallons b.N/A R= ft2 EF:0.92 c. N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building " FTHE ST9T•• Construction through the above energy saving features which will be installed (or exceeded) O _ Fo in this home before final inspection. Otherwise,a new EPL Display Card will be completed ; "''%• '>:'"=s'' .i4,- based on installed Code compliant features. ,•'h,;,,,,,, ,: = 0=. Builder Signatul i< - Date: (/ - // / )� i'' `-� `y Address of New Home: I -1 ©e, City/FL Zip: ,/ �(a,L, /3e, -.. 3ZL3y wE *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/4/2015 3:27 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Florida Code 2014 Summary Report Title: HABITAT-QUADPLEX-OUTSIDE-D-R-185 TMY City: FL_JACKSONVILLE_ 185 OCEAN GATE DRIVE FLProp2014 Elec Util: Florida Average ATLANTIC BEACH , FL, 32233 Gas Util: Florida Average Registration #: Run Date: Energy Uses Reference Home Proposed Home e-Ratio Heating 2.43 MBtu 1.37 MBtu 0.56 Cooling 5.66 MBtu 4.95 MBtu 0.87 Hot Water 8.58 MBtu 8.94 MBtu 1.04 Total 16.67 MBtu 15.26 MBtu 0.92 Building Loads Reference Home Proposed Home e-Ratio Heating 5.13 MBtu 2.89 MBtu* 0.56 Cooling 18.15 MBtu 15.87 MBtu* 0.87 Hot Water 8.41 MBtu 8.76 MBtu* 1.04 Total 31.69 MBtu 27.52 MBtu 0.87 * normalized modified loads Glass/Floor Area: 0.111 Total Proposed Modified Loads: 27.52 PASS Total Reference Loads: 31.69 11/4/2015 3:27 PM EnergyGauge®USA-FlaRes2014/ Page 1 of 1 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-QUADPLEX-OUTSIDE-D-R-185 Builder Name: BEACHES HABITAT Street: 185 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/4/2015 3:27 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 185 OCEAN GATE DRIVE ATLANTIC BEACH .FL,32233 Permit Number: I MANDATORY REQUIREMENTS See individual code sections for full details. Xl 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. KJ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. C R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed.but not sealed. beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust.intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures: 3. Interior doors,if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test.shall be fully open. C R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. C R402.4.3 Fenestration air leakage Windows.skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMAM/DMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. C R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. i R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. In R403.2.2 Sealing(Mandatory)4ll ducts,air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55'F(13'C)shall be insulated to a minimum of R-3., C R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight,moisture.equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. gl R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies O R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code.Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806.Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal:and 2. Be installed at an orientation within 45 degrees of true south. I=1 R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. O R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics.crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. C R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) C R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal. rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer, in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. c R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. • R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40`F. ❑ R403.9 Swimming pools, inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. c; R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. C; R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ▪ solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. o R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 10/9/2015 8:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 Manual S Compliance Report Job: QUADPLEX-OUTSIDE UNI... +�+ wrightsoft p p Date: 1012015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEtENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT-D, BEACHES HABITAT 185 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.0°F Sensible gain: 17903 Btuh Entering coil DB: 76.2°F Outdoor design WB: 78.0°F Latent gain: 2425 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 20328 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A"30+FX4DNF025 Actual airflow: 800 cfm Sensible capacity: 21971 Btuh 123%of load Latent capacity: 744 Btuh 31%of load Total capacity: 22715 Btuh 112%of load SHR: 97% Heating Equipment Design Conditions Outdoor design DB: 39.0°F Heat loss: 21429 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A**30+FX4DNF025 Actual airflow: 800 cfm Output capacity: 23554 Btuh 110p/o of load Capacity balance: 36 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 5.2 kW 83%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 201 5-Oct-30 14:58'05 "f{{" wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 ACC* ...htsoft HVACIHABIJAX-QUAD-OUTSIDE UNIT-D-MJ2.rup Calc=MJ8 Building Front faces' W �.�;,,, Residential Plans Examiner Review Form Form ACCt . for HVAC System Design (Loads, Equipment, Ducts) RPER 1 15Mar09 I Cordrs+vt iyartm,nA rra Header Information Contractor: FLORIDA AIR SERVICE&ENGINEERING REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ® No ❑ Mechanical license: CAC1813923 or MJ1AE Form'(and supporting worksheets): Yes ❑ No El OEM performance data(heating,cooling,blower): Yes El No ❑ Building plan#: Manual D Friction Rate Worksheet: Yes El No ❑ Duct distribution sketch: Yes ZI No ❑ Home address(Street or Lot#,Block,Subdivision): 185 OCEAN GATE DR, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 39 °F Orientation: Building Front faces West °F North,East,West,South,Northeast,Northwest.Southeast,Southwest Indoor temperature: 70 Total heat loss: 21429 Btuh Number of bedrooms: 3 Conditioned floor area: 1170 ft' Summer Design Conditions Number of occupants: 0 Outdoor temperature: 92 °F Indoor temperature: 75 °F Windows ka.' Grains difference: 58 gr/Ib @50% RH Eave overhang depth: 8.0 ft Sensible heat gain: 17903 Btuh Internal shade: none Eave Latent heat gain: 2425 Btuh Blinds,drapes.etc. Depth ,Vali.'u Total heat gain: 20328 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Eq lipm -nt Data Blower_Data Equipment type: Split ASHP Ec�uipcment type: Split ASHP Heating cfm: 800 urnace,Hea pump,Boiler.etc. it onditioner,Heat pump,etc. Cooling cfm: 800 Model: Carrier Model: Carrier Static pressure: 0.50 in H2O 25HBC524A'"30+FX4DNF025 25HBC524A"30+FX4DNF025 Fan's rated external static pressure for design airflow Heating output capacity: 3554 Btuh Total cooling capacity: 22715 Btuh Heat pumps-capacity at winter design ou oor conditions Sensible cooling capacity: 21971 Btuh Aux.heating output capacity: 17762 Btuh Latent cooling capacity: 744 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 800 cfm Longest supply duct: 377 ft Duct Materials Used Equipment design ESP: 0.50 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 377 ft Available static pressure(ASP): 0.50 in H2O Friction rate:0 , 0 in/100ft Branch duct: Round flex vinyl Friction Rate=ASP+(TEL x I declare the load calculation.equipment. equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: J FERNANDEZ Contractors signature: J FERNANDEZ(ESIGN) Date: 11/2015 Reserved for County. Town Municipality or Authority having jurisdiction use. 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist -F}F- wrightsoft Right-Suite®Universal 2015 15.0.17 RSU1 3554 4 wrightsoft Load Short Form Da e: 10L ODSLEX-OUTSIDE UNI... Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEGENGINEER.COM Web:WWVV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT- D, BEACHES HABITAT 185 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Design Information Htg Clg Infiltration Outside db(°F) 39 92 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 31 17 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 40 50 Moisture difference(grub) 16 58 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC524A**30 Cond 25HBC524A**30 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17718 Btuh Heating output 23554 Btuh @ 47°F Latent cooling 4997 Btuh Temperature rise 27 °F Total cooling 22715 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) BATH2 96 736 393 27 18 MBED 196 10341 9114 386 407 BED2 158 2063 1253 77 56 GREAT 249 3160 4301 118 192 MWIC 32 490 94 18 4 BATH1 52 100 130 4 6 M EC H 48 502 127 19 6 BED3 151 1997 1205 75 54 KITCHEN 188 2040 1286 ' 76 57 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2015 Oct-30 14:58:e 1 Right-Suited Universal 2015 RSU13554 Pagel ACCt1 ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-D-MJ2.rup Calc=MJ8 Building Front(aces: W Entire House 1170 21429 17903 800 800 Other equip loads 0 0 Equip. @ 1.00 RSM 17903 Latent cooling 2425 TOTALS I 1170 I 21429 I 20328 I 800 I 800 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Oct-30 14:58:06 wrightsoft Right-SuiteSUniversaI 201515.0.17RSU1354 t Paget ACCA ...htsolt HVAC\HABIJAX-QUAD-OUTSIDE UNIT-D-MJ2.rup Calc=MJ8 Building Front faces: W 4 wrightsoft Building Analysis Job: QUADPLEX-OUTSIDE UNI... Date: 10/2015 Entire House FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAElENGINEER.COM Web:WVWV.NORTHFLORIDAAIR.COM Pro'ect Information For: QUADPLEX-OUTSIDE UNIT- D, BEACHES HABITAT 185 OCEAN GATE DR, ATLANTIC BEACH, FL 32233 Desi• n Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range - 15 ( I ) Method Simplified Wet bu lb(° F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Heatin• Component Btu h/ft2 Btuh %of load Walls 2.0 1264 5.9 Glazing 48.2 11609 54.2 Doors 0 0 0 Ceilings 1.0 1161 5.4 Floors 1.2 1431 6.7 Infiltration 3.8 3373 15.7 Ducts 2591 12.1 ' -•• Piping 0 0 W' Humidification 0 0 �^ Ventilation 0 0 Adjustments 0 Total 21429 100.0 Coolin• Component Btu h/ft2 Btuh % of load Walls 1.2 768 4.3 Glazing 46.7 11261 62.9 Doors 0 0 0 ! .v Ceilings 1.7 2035 11.4 Floors 0 0 0 Infiltration 0.8 754 4.2 Ducts 3084 17.2 I Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 17903 100.0 Latent Cooling Load =2425 Btuh Overall U-value=0.155 Btuh/ft2-°F Data entries checked. 2015.0c1-30 14:58:06 wrightsoft Rig ht-Su itee Universal 2015 15.0.17 RSU13554 Page 1 ACCA ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-D-MJ2.rup Calc=MJ8 Building Front faces: W Project Summa Job: QUADPLEX-OUTSIDE UNI... wrightsoft Summary Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone.904-823-9696 Email.FAEIENGINEER.COM Web:WVWJ.NORTHFLORIDAAIR.COM Pro'ect Information For: QUADPLEX-OUTSIDE UNIT-D, BEACHES HABITAT 185 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Notes: Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 58 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18837 Btuh Structure 14819 Btuh Ducts 2591 Btuh Ducts 3084 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21429 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17903 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1596 Btuh Ducts 829 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1170 1170 Equipment latent load 2425 Btuh Volume(ft3) 10530 10530 Air changes/hour 0.56 0.23 Equipment total load 20328 Btuh Equiv. AVF (cfm) 99 40 Req.total capacity at 0.78 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC524A**30 Cond 25HBC524A**30 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 8.7 HSPF Efficiency 12.0 EER,15.25 SEER Heating input Sensible cooling 17718 Btuh Heating output 23554 Btuh @ 47°F Latent cooling 4997 Btuh Temperature rise 27 °F Total cooling 22715 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rrT- wri htsoft 2015-Oct-30 14:58:06 1 9 Right-Suite®U niversal 2015 15.0.17 RSU13554 Page 1 AC-CA ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-D-MJ2.rup Calc=MJ8 Building Front faces. W +y+ Job: QUADPLEX-OUTSIDE UNI...wrightsoft Loads for Multiple Orientations Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:WWVV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT- D, BEACHES HABITAT 185 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling temperature (OF) 70 75 m t door ep Jacksonville Mayport Naval, FL, US Indoor 31 17 Elevation: 16 ft Design TD (°F) Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) Wet bulb(°F) - 78 Wind speed (mph) 15.0 7.5 Building Front North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 19108 17084 19672 21474 22148 19993 17903 19790 Latent Load (Btuh) 2425 2425 2425 2425 2425 2425 2425 2425 Total Load(Btuh) 21533 19509 22097 23899 24573 22418 20328 22215 Heating AVF (cfm) 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 Cooling AVF (cfm) - Building Orientation Cooling Load 1-u' MI • 0 I g S SN W NA/ N NE E Drectim Bul irg Fiat faces Current Orientation: Building Front faces West Highest Cooling Load: Building Front faces South Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Oct-30 14:58:06 ,..,. wrightsoft Right-Suite®Universal201515.0.17 RSU13554 Page 1 ACC* ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-D-MJ2.rup Calc=MJ8 Building Front laces. W Summary System Duct S Job: QUADPLEX-OUTSIDE UNI... + ' wrightsoft y y Date: 10/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEQENGINEER.COM Web:WVWV.NORTHFLORIDAAIR.COM Project Information For: QUADPLEX-OUTSIDE UNIT- D, BEACHES HABITAT 185 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 i Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.500 in/100ft 0.500 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 377 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk MECH h 542 28 10 0.500 4.0 Ox 0 VIFx 307.0 70.0 BATH2 h 818 42 30 0.500 4.0 Ox 0 VIFx 307.0 70.0 MBED h 3382 172 147 0.500 7.0 Ox 0 VIFx 307.0 70.0 BED3 h 2297 117 96 0.500 6.0 Ox 0 VIFx 307.0 70.0 KITCHEN h 2343 119 103 0.500 6.0 Ox 0 VIFx 307.0 70.0 BED2 h 2366 120 100 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT c 2148 85 148 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT-A c 2148 85 148 0.500 6.0 Ox 0 VIFx 307.0 70.0 BATH1 c 148 6 10 0.500 4.0 Ox 0 VIFx 307.0 70.0 MWIC h 530 27 7 0.500 4.0 Ox 0 VIFx 307.0 70.0 I NI 0 0 2015-Oct-30 15:31:55 wrightsoft Right-Suited Universal 2015 15.0.17 RSU13554 Pagel ACCT. ...ghtsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-D-MD.rup Calc=MJ8 Building Front faces: W