1696 ATLANTIC BEACH DR - DENSITY REPORT U 11 I V E R S A L UES Project No: 0910.1400187.0000
RI p Workorder No: 165468-1
ENGINEERING SCIENCES Report Date: 01/08/2016
Consultants In:Geotechnical Engineering•Environmental Sciences
Geophysical Services•Materials Testing•Threshold Inspection
Building Code Administration,Compliance Inspection&Plan Review
5561 Florida Mining Blvd So.,Jacksonville,FL 32257 -P:904-296-0757 -F:904-296-0748
In-Place Density Test Report
Client: Toll Brothers, Inc UES Technician: Casey Turner
160 Cape May Avenue Date Tested: 01/07/2016
Ponte Vedra, FL 32081
Project: Atlantic Beach Country Club
Atlantic Beach Country Club,Atlantic Beach, Duval County, FL 32233
Tvoe of Test:
Area Tested: 1696 Atlantic Beach Dr. Lot#82 Field: ASTM D-6938 Nuclear Gauge Method
Material: Fill Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0 = Top of Fill
The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density.
Maximum Optimum Field Dry Field Soil Pass
Test Density Moisture Density Moisture Compaction or
No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail
1 southwest corner 0-1 ft 103.3 14.3 100.2 9.9 97 Pass
2 southeast corner 0-1 ft 103.3 14.3 102.3 10.3 99 Pass
3 northeast corner 0-1 ft 103.3 14.3 101.5 8.9 98 Pass
4 northwest corner 0-1 ft 103.3 14.3 102.5 10.8 99 Pass
C a ii) 10 Pe 1 vrA ‘i '
---c\', / -e_ ,
fr
/ -/ I ! 6
To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and
authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.