Loading...
1696 ATLANTIC BEACH DR - DENSITY REPORT U 11 I V E R S A L UES Project No: 0910.1400187.0000 RI p Workorder No: 165468-1 ENGINEERING SCIENCES Report Date: 01/08/2016 Consultants In:Geotechnical Engineering•Environmental Sciences Geophysical Services•Materials Testing•Threshold Inspection Building Code Administration,Compliance Inspection&Plan Review 5561 Florida Mining Blvd So.,Jacksonville,FL 32257 -P:904-296-0757 -F:904-296-0748 In-Place Density Test Report Client: Toll Brothers, Inc UES Technician: Casey Turner 160 Cape May Avenue Date Tested: 01/07/2016 Ponte Vedra, FL 32081 Project: Atlantic Beach Country Club Atlantic Beach Country Club,Atlantic Beach, Duval County, FL 32233 Tvoe of Test: Area Tested: 1696 Atlantic Beach Dr. Lot#82 Field: ASTM D-6938 Nuclear Gauge Method Material: Fill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Top of Fill The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail 1 southwest corner 0-1 ft 103.3 14.3 100.2 9.9 97 Pass 2 southeast corner 0-1 ft 103.3 14.3 102.3 10.3 99 Pass 3 northeast corner 0-1 ft 103.3 14.3 101.5 8.9 98 Pass 4 northwest corner 0-1 ft 103.3 14.3 102.5 10.8 99 Pass C a ii) 10 Pe 1 vrA ‘i ' ---c\', / -e_ , fr / -/ I ! 6 To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.