1757 ATLANTIC BEACH DR - DENSITY TEST Eig& PROJECT NO: 4803-0014 LAB Ellis&Associates inc. DATE TOESTED: 01/08/2016
7064 Davis Creek Road REPORT NO: 1-0003
Jacksonville,FL 32256
(904)880-0960 Office DATE: 01/15/2016
(904)880-0970 Fax L
REPORT OF: RESIDENTIAL IN-PLACE DENSITY TEST S Ca � `
PROJECT: Atlantic Beach Country Club
Atlantic Beach, Duval County, FL L-5-- 5F.k^07av
ATTENTION: Mr Ryan Odell
REPORTED TO: Riverside Homes Inc
Suite 120
12276 San Jose Blvd
Jacksonville, FL 32223
TEST RESULTS Page 1 of 1
Field Number: Lot 34
General Location: 1757 Atlantic Beach Drive
Specific Location: House Pad
Course: Fill
Test
Test Depth Dry Percent
In Percent Density Proctor Spec Proctor
No.
(in) Location Moisture (pcf) Number No. Density Pass/Fail
1 12 Southeast Corner 10.2 98.4 115208 1 95 Pass
2 12 Northwest Corner 9.6 99.0 115208 1 96 Pass
3 12 Center 9.9 99.6 115208 1 96 Pass
Proctor Proctor Optimum Maximum LBR
No Date Moisture Dry Density Value Description Location
115208 01/05/2016 14.6 103.6 N/A Brown Fine Sand House Lot
Specification
Specification No. Compaction, %
1 95 Min
Date Received:01/08/2016 Date Tested: 01/08/2016
Gauge No.: 7
Test Methods: ASTM D6938-08a
Ong:Riverside Homes IncAttn:Mr Ryan Odell (1-ec copy) Respectfully Submitted,
Ellis &Associates, Inc.
This document has been digitally signed in accordance
with Florida Statute 61G15-23.003 on 01/19/2016.
Nemer(Nick)Y.Oweis.P.E.
Technician: Adam Jackson CMT Department Manager
(KMG) Licensed,Florida No.44755
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S)TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF