1021 ATLANTIC BLVD UNIT 967 - FIRE SERVICE DRAWINGS CODE REQUIREMENTS Q00 ARCHITECTURAL" THE PROJECT IS A REMODEL OF AN EXISTING RESTAURANT. THE BUILDING IS CONSTRUCTED G-1 CODE DATA A WITH LOAD-BEARING STEEL COLUMNS, STEEL BEAMS, BAR JOISTS AND METAL DECK. 0 (n o C �/ FLORIDA BUILDING CODE 5th EDITION (2014) ? w o G-2 LIFE SAFETY PLAN FLORIDA FIRE PREVENTION CODE 5th EDITION (ENCOMPASSING THE 2012 EDITIONS OF NFPA 1 & NFPA 101) `s A-1 EXISTING FLOOR PLAN FLORIDA BUILDING CODE - ACCESSIBILITY 5th EDITION (2014) FLORIDA BUILDING CODE EXISTING 5th EDITION (2014) - LEVEL 2 ALTERATION (FBC-E 504.1) A-2 FLOOR PLAN &WALL TYPES # ¢ - OCCUPANCY CLASSIFICATION OF TENANT SPACE: ASSEMBLY (A-2) FBC 303.1; NFPA 3.3.22, 3.3.178.2 AND CHAPTER 12. RESTAURANTS AND DRINKING ESTABLISHMENTS WITH AN OCCUPANT LOAD OF GREATER " 2 Q THAN 50 PERSONS. , 'O� U Q CONSTRUCTION: FBC SECTION 602.2 - TYPE IIB, UNSPRINKLED 14 ALLOWABLE HEIGHTS AND BUILDING AREAS: TABLE 503 - TYPE IIB, UNSPRINKLED `� °' �-s MAX. HEIGHT - 55'-0>, MAX. STORIES - 2 BASIC ALLOWABLE AREA - 9,500 SQ. FT. TENANT SPACE AREA: 4,509 SF ❑❑ ❑❑ TYPE IIB - TABLE FBC 601 ❑ BUILDING ELEMENT TYPE 1113El z-- Q a STRUCTURAL FRAMEU)p s INCLUDING COLUMNS, GIRDERS, TRUSSES 0� cM rn W o BEARING WALLS z N EXTERIOR 0 o INTERIOR LJJ o0 Z co Lo Za NONBEARING WALLS AND PARTITIONS 0 W od M t w EXTERIOR ow toLLQ 4- .. _ . NONBEARING WALLS AND PARTITIONSp U) 0 j ® INTERIOR W ujma� �, � CD FLOOR CONSTRUCTIONp a r _ ai _ o o 4- r INCLUDING SUPPORTING BEAMS AND JOISTS W _ o o co U J �. = V � o4t4 -0 cac� ROOF CONSTRUCTION ALV N •a'D p OG1Q I mmaC) o'a INCLUDING SUPPORTING BEAMS AND JOISTS I- rn ULU- TYPE IIB TABLE FBC 602 FIRE SEPARATION DISTANCE TYPE OF CONSTRUCTION GROUP A-2 (FT) PROJECT LOCATIO i �1 < 5 OTHERS 1 a• > 5 OTHERS 1 < 10 PROJECT SITE < 20 LIB 0 01 a• fl Lu FLORIDA STATE MAP > 20 r� DUVAL/ST.JOHNS COUNTY MAP 8 < 30 OTHERS p r� NOT TO SCALE m CN D N > 30 ALL p r0 z T S L Q04 0 m lJ S �TE INITY P SEPARATED ACCESSORY OCCUPANCIES (FBC TABLE 508.4): z SEPARATION OF AN ASSEMBLY OCCUPANCY FROM A MERCANTILE OR BUSINESS OCCUPANCY - 3c 1= _ 2 HR WITHOUT A SPRINKLER SYSTEM z U SEPARATED ACCESSORY OCCUPANCIES (FLORIDA FIRE PREVENTION CODE TABLE 6.1.14.4.1(a & b)): Q m SEPARATION OF AN ASSEMBLY OCCUPANCY FROM A MERCANTILE OR BUSINESS OCCUPANCY - `L ' N.T.S. �'� ° 2 HR WITHOUT A SPRINKLER SYSTEM. Q C `�� � C�� OCCUPANT LOAD: MINIMUM OCCUPANT LOAD - FBC TABLE 1004.1 .1 (NFPA TABLE 7.3.1.2 8c 42.1.7): t I COBBLESTONE 2''' q� MERCANTILE: 30 GROSS SF PER PERSON Q PARKWAYOFFICE: 100 GROSS SF PER PERSON 'A Alkh NOTE A: COMMERCIAL KITCHEN (PREP AREA : 200 GROSS SF PER PERSON EXIT DOOR TACTILE COMMERCIAL KITCHEN (PREP AREA): 100 GROSS SF PER PERSON PPC)MCORMiGK RD SIGNAGE READING: STORAGE, STOCK: 300 GROSS SF PER PERSON EXIT QUEUING AREA: 5 NET SF PER PERSON SIGNAGE SHALL z z COMPLY w/ANSI/CABO C)< �QUEUING AREA 36 SF (NET)/5 SF PER PERSON = 7 OCCUPANTS A117.1; > >w 4 PERSON BANQUETTES & BOOTHS (4 x 12) =48 OCCUPANTS MOUNT = 5 OCCUPANTS o o0f Q 3 PERSON BANQUETTE ( x 5 x ) IL > 5 PERSON BANQUETTE 60 AFF TO (3 1 ) 3 OCCUPANTS o CENTERLINE OF rK wo 8 PERSON TABLES & BANQUETTE (8 x 4) =32 OCCUPANTS SIGN LOCATION OF SIGN o v¢ WALK-IN-COOLER 142 SF (GROSS)/300 SF PER PERSON 3 OCCUPANTS loo KITCHEN 566 SF (GROSS)/200 SF PER PERSON SHALL COMPLY WITH = 1 OCCUPANT SUBTOTAL =99 OCCUPANTS cATLANTIC BLVD FBC-ACCESSIBILITY 703 LESS THAN 100 PEOPLE; NO C BL�p SPRINKLER SYSTEM REQUIRED (FBC 903.2.1 .2) OUTDOOR SEATING =30 OCCUPANTS D TOTAL =129 OCCUPANTS �� z QUEUING AREA 36 SF (NET)/5 SF PER PERSON 7 OCCUPANTS C° 4 PERSON BANQUETTES & BOOTHS (4 x 12) =48 OCCUPANTS z ro z Dw 5 PERSON BANQUETTE (5 x 1) = 5 OCCUPANTS z �' ¢ o Uw 3 PERSON BANQUETTE (3 x 1) = 3 OCCUPANTS of Ld a w o� 8 PERSON TABLES & BANQUETTE (8 x 4) =32 OCCUPANTS Y p > wo KITCHEN 566 SF (GROSS)/100 SF PER PERSON = 6 OCCUPANTS F, op D_ u J WALK-IN-COOLER 142 SF (GROSS)/300 SF PER PERSON = 1 OCCUPANT - SUBTOTAL =102 OCCUPANTS BEACH BLVD ^^ LESS THAN 300 PEOPLE; NO C) STREET MAP125P INDICATES EXIT OR EXIT ACCESS, NUMBER OF SPRINKLER SYSTEM REQUIRED PROJECT SITE NOT TO SCALE 32„ PERSONS ( ') DISCHARGING AT EXIT OR EXIT ACCESS, (FFPC/NEPA 101 12.3.5.2) AND EGRESS CLEAR WIDTH (AT DOORS). OUTDOOR SEATING =30 OCCUPANTS Li TOTAL -132 OCCUPANTS Q o®m v m m m SAMPLE EGRESS TRAVEL PATH AND DISTANCE INTERIOR FINISHES: o MINIMUM AS REQUIRED BY FBG TABLE 803.9 (UNSPRINKLED): ■ � � � � EXISTING TWO-HOUR FIRE-RATED TENANT SEPARATION WALL FIELD VERIFY w PLUMBING FIXTURE COUNT PER TABLE 403.1 FLORIDA PLUMBING CODE ( ) OCCUPANCY VERTICAL EXITS EXIT ACCESS CORRIDORS ROOMS & ENCLOSED SPACES D o ASSEMBLY (A-2) A A B 0 RESTAURANT (A-2) Z Q WATER CLOSETS 1 WC PER 75 MALES AS REQUIRED BY NFPA 101 TABLE A.10.2.2: Lo W 1 WC PER 75 FEMALES OCCUPANCY VERTICAL EXITS EXIT ACCESS OTHER SPACES "i z Z o TOTAL OCCUPANT LOAD - 129 FIRE EXTINGUISHER TYPE A (UL RATING 3A-40B:C) 5 LB MULTIPURPOSE DRY CHEMICAL ASSEMBLY < 300 A OR B A OR B A OR B § m v_ EQUAL TO BAD GER MODEL #5MB-6H {A KIDDE COMPANY) < z w o �- 65 MALESFIRE EXTINGUISHER TYPE "B" (UL RATING 2-A:K) 6 LITER (1.56 GAL) EXTINGUISHER FOR CLASS K FIRES CLASS A INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450 o a Z N w 65 FEMALES EQUAL TO KITCHEN ONE MODEL #KS-6000 BY PYRO-CHEM CLASS B INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450 uj W W a o FIRE EXTINGUISHERS SHALL BE CERTIFIED BY A LICENSE FIRE PROTECTION COMPANY 1 WATER CLOSET & 2 URINALS CAN ACCOMMODATE 225 MALES CLASS C INTERIOR WALL AND CEILING FINISH FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450 z V,C) Z 2 WATER CLOSETS CAN ACCOMMODATE 150 FEMALES CLASS A FIRES (ORDINARY COMBUSTIBLE MATERIALS F of SUCH AS WOOD, CLOTH, PAPER RUBBER AND MANY PLASTICS) MEANS OF EGRESS: = a= 1 LAV PER 200 PEOPLE CLASS B FIRES (LIQUIDS, TARS, OILS, GASES) MAXIMUM TRAVEL DISTANCE, DEAD END LENGTH, EXIT AND MEANS OF EGRESS WIDTH: a a o DRAWN BY: CAS CLASS C FIRES ELECTRICAL EQUIPMENT) FBC TABLES 1005.1 & 1016.1 , & FFPC/NFPA TABLE A.7.6, 12.2.5 & 12.2.6: cr N 4 LAVATORIES CAN ACCOMMODATE 800 PATRONS CLASS K FIRES ((CO KING MEDIA VEGETABLE OR ANIMAL OIL AND FATS) MAXIMUM TRAVEL DISTANCE TO EXIT (UNSPRINKLED): ASSEMBLY - 200 FT W O oo CHECKED BY: CAS PLUS ONE UNISEX TOILET ROOM MAXIMUM FLOOR AREA PER UNIT OF A = 1,500 SF NFPA 101 - 200 FT (ASSEMBLY NFPA 12.2,6.2) 0 MAXIMUM FLOOR AREA PER 2A UNIT = 3,000 SF MAXIMUM TRAVEL DISTANCE MAXIMUM DEAD END CORRIDOR LENGTH (ASSEMBLY): 20 FT (FBC 1018.4) SERVICE SINKS 1 SERVICE SINK MAXIMUM TRAVEL DISTANCE TO AN EXTINGUISHER 75 FT TOA K EXTINGUISHER = 30 FT NFPA 101 - 20 FT (ASSEMBLY NFPA 12.2.5.1.3) om0 Of DATE: 11 -10-15 EGRESS WIDTH PER PERSON SERVED: a o o } DRINKING FOUNTAINS (FLORIDA PLUMBING CODE SECTION 410.1): OTHER EGRESS COMPONENTS (CORRIDORS, RAMPS, ETC.) = .02" (©.2" x 94 OCCUPANTS ~ ~� Q DRINKING FOUNTAINS SHALL CONFORM TO ASME Al 12,19.1 M, o,Z, o ASME Al 1219.2M OR ASME Al 12.19.9M, AND WATER COOLERS 18.8" REQUIRED 96" PROVIDED; 96" CAN ACCOMMODATE 480 PEOPLE) Z Z o SHEET SHALL CONFORM TO ARI 1010. WHERE WATER IS SERVED IN MINIMUM CORRIDOR AISLE WIDTH: 44" (FBC 1018.2 & FFPC 12.2.3.8) o Q o H N Z Z RESTAURANTS DRINKING FOUNTAINS SHALL NOT BE REQUIRED. MINIMUM CLEAR WIDTH OPENING OF EXIT DOORS: 32" (32"/.02" PER PERSON = 160 PERSONS) _ Z,a 29 m w w 0 o DOORS SHALL SWING IN THE DIRECTION OF EGRESS EXCEPT WHEN SERVING AN > co W OCCUPANT LOAD OF LESS THAN 50 (FBC 1008.1.2) N 02 m =ZWZ COMMON PATH OF TRAVEL (UNSPRINKLED): 75 FT (FBC 1014.3); JaZ NFPA 101 20 FT; 75 FT FOR LESS THAN 50 PEOPLE (ASSEMBLY) (FFPC 12.2.5.1 .2) W ui CORRIDOR FIRE-RESISTANCE RATING (FBC TABLE 1018.1): ASSEMBLY GREATER THAN 30 OCCUPANTS w/OUT w a a A SPRINKLER SYSTEM- 1 HOUR FIRE RATING REQUIRED W Of w a DOORS SHALL SWING IN THE DIRECTION OF EGRESS EXCEPT WHEN SERVING AN OCCUPANT LOADW�W Lo OF LESS THAN 50 (FBC 1008.1 .2) o�=_n Q � Q d ccs W o Lij ry WALK-IN COOLER ❑❑ v ❑❑ 160P 160P El 32 " 32" — cra NOTE A NOTE A W rn 1FE-"A" w M m FE- B , (n Z o N - CLASS K FIRE EXTINGUISHER r [ r� a - FIELD VERIFY LOCATION ' e 62 i - w (� a cc a G z ca Z a N w p OV) � FC-1 e _' _ ® cn l— Ed a 1 w 00-4- WCD _ PRIVAT OFFICE I---- _ ® � — Q=o o �CE c m 00) w = OFFICE I I Q = v T N cc 0:D c of v- (A WOMEN'S MENSI oc auIT � = KITCHEN e 1 - O o Q M�� � 00 I*- TOILET TOILET � _ 1 e 1 _ t e 1 77 -- -- ® e 1 I o UNISEX - ` JTOILET I CL 10 m C"� _ C m I w — PRIVATE z v I DININGXXXXXXN 50 ♦ - Q ADVANCE - , ® 1 48 — z W AMERICA / e f4 A . CASH - ADVANCE e - 1 � , ® I , 1 NAVY OCCUPANCY I SE ♦ 1 - FEDERAL 1 AREA 1 1 CREDIT UNIONI I (B) 1El 40 ' ♦ 1 e = OCCUPANCY e - FE-„A„ 1 DINING DINING 1 1 BAR e — ® I � CL CD> 77 I ® _ LLJ ----------- d1 ♦ ILL------- L-------------- _— _----_--_ ! ® ENTRY/HOSTESSLLJ ® - - � ~ _ Z � - � o � L, 1 z QZ♦ ® 'i oN W I — N w I u e - = oW� o r—�uj V7 Z --- --- --------� , z =� z x x NOTE A NOTE A a a o DRAWN BY: CAS �oI � 160P 160P a � uj� 9 000 00 0 CHECKED BY: CAS 32 32 aoN � r o W o W DATE: 11-10-15 OUTDOOR zm a opz SEATING F- ~LJQ IoW SHEET WZ mom . _ = Z lY WWo N W W As Z W o - J - Z d W J G _ Q W N F = LIFE SAFETY PLAN Z- la 2 XB� Z SCALE: 1/4"= 1�_0�� W o o J W O� 0- LLJ W =xLI) WCL = O F-W I- j Q 0 00 <C dt (/) 0 "1 1�ryW - e,^ 0 U Q WALK-IN COOLER ❑m ❑❑ ❑ z o w cn W a � z om w o0 0 Z mN z° 5 w to xsM to O cn a pU) 0 �Z w CC v(i 00 a> a = �/ y �rnrn cavi PRIVAT OFF CE ---- --� w = �_> �U GENERAL NOTES: OFFICE rn 1. PATCH AND REPAIR ALL EXISTING MATERIALS AND FINISHES AT WALLS, FLOORS _ �' O-.4- d -q m t6 T_ NN N "D T3 AND CEILINGS WHERE AFFECTED OR DAMAGED BY NEW CONSTRUCTION OR MEN'S WOMEN'S 0 o 0 r- 0 REMOVAL OF EXISTING CONSTRUCTION. MATERIALS AND FINISHES SHALL MATCH ❑ Q M-�rn m 1E M KITCHEN EXISTING CONSTRUCTION AND FINISHES, ALL OPENINGS IN FLOORS, WALLS AND TOILET TOILET CEILINGS RESULTING FROM DEMOLITION OPERATIONS SHALL BE INFILLED WITH MATERIAL TO MATCH EXISTING CONSTRUCTION AND FINISHES. FIRE RATINGS OF EXISTING WALLS SHALL BE MAINTAINED. 2. FIELD VERIFY DIMENSIONS AND EXISTING CONDITIONS BEFORE STARTING WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT OR ENGINEER. ----- 3. VERIFY EXISTING FIRE RATINGS ON EXISTING PARTITIONS, PARTITIONS THAT ARE CUT TO INSTALL PLUMBING, ELECTRICAL & MECHANICAL SYSTEMS SHALL BE PATCHED AS REQUIRED TO MAINTAIN FIRE RATINGS. 4. REMOVE & REPLACE EXISTING .FRONT SIDEWALK AND RAISE SIDEWALK TO LEVEL WITH FINISHED FLOOR SLAB. RAISE WATER METER AND CLEAN OUT. j UNISEX 71 ui 8 W 5. REMOVE EXISTING SWITCHES, RECEPTACLES, JACKS, CONDUITS, ETC. ON WALLS ! o NOTED TO BE REMOVED, REMOVE WIRING BACK TO EXISTING PANEL BOXES ! TOILET O c�i AND REMOVE EXISTING BREAKERS. ! ❑ w > � m J DEMOLITION NOTES: ! W z v _ 1. ___= INDICATES WALLS, FIXTURES AND COUNTER TO BE REMOVED ! Q PRIVATEly Oc 2. REMOVE & REPLACE EXISTING ACOUSTICAL DROPPED CEILING IN THE DINING & LARGE TOILET ROOM. ------ f r ------ ¢ w 3. REMOVE & EXISTING ACOUSTICAL DROPPED CEILING OVER THE BAR AS NOTED & PROVIDE RAISED DINING _- ---- ---- Q m (24") EPDXY PAINTED GYPSUM WALLBOARD CEILING. I I CJ cy) Z I j Imo, I I ; I SERVERI / REMOVE EXISTING ACOUSTICAL I CEILING AND RAISE CEILING OVER AREA I i BAR 24" & PROVIDE NEW EPDXY i PAINTED GYP BOARD CEILING X I I I ! I I I I I II• I I I ii DINING STAGE SERVER BAR DINING AREA REMOVE EXISTING SERVER BAR AND INSTALL NEW BAR TO MATCH EXISTING AND z ——r PROVIDE NEW BAR TOP n o ! V r I C) C) ry i ; r--------- ! (D ! !I ! L------------- I REMOVE EXISTING BOOTH & z I ! ! I I ----------------------------- PARTITIONS AS REQUIRED � 1 " ---- — FOR NEW CONSTRUCTION x L---------- ---- - W Q uj REMOVE EXISTING WALL & LJ 100 ! :'i N o ! SEATING AS REQUIRED FOR < z W o NEW CONSTRUCTION, PATCH I Z� 0 w & REPAIR FLOORING l t o w = C) REMOVE EXISTING ELEVATED ER SEATING; --------r -"----� � a TORM L =PACH & REPAIR R FLOOR TO z MATCH EXISTING ——— a DRAWN BY: CAS o, �z 1 wo�� \ w u o o CHECKED BY: CAS ao} 17'-18„ 17'-48" 17'-48„ 17'-�'❑ o uj o DATE: 11 -10-13 =1N roloo r�100 SIN G m o a •—I�t 'Z O O Z d Nw r OUTDOOR REMOVE EXISTING SINGLE = �Z ` c0 STOREFRONT DOOR & PROVIDE SINGLE � z Z SHEET SEATING WOOD DOOR W/PANIC HARDWARE; MODIFY o Q o STOREFRONT GLASS AS REQUIRED (PROVIDE _ V)a m TEMPERED GLASS ADJACENT TO DOOR) w W o 0 > oNw N �0m ul QRZ r-'n a uj EXISTING FLOOR PLAN WN~ = 1 = uEw a ZZ �� w a'W J wav>a SCALE. 1/4 1 -Q Z w w w L) v,ww ( <n w a. w w x i o w I Q 0 co Q d CO co 0 KEY PLAN NEW WALLS o CIO KNEE WALL: 3 5/8", 20 GA METAL STUDS .. `. @ 16" O.C, (ALIGN FINISHES ON BOTH SIDES OF WALL), Q - 1/2" PAINTED GYP BD Li AND WOOD MOLDINGS, WAINSCOTING & BASEBOARDS TO MATCH EXISTING. MATCH HEIGHT OF _ ADJACENT KNEE WALLS v U m TYPICAL INTERIOR PARTITION: 3 5/8", 20 GA METAL STUDS Q @ 16" O.C. (ALIGN FINISHES ON BOTH SIDES OF WALL), 1/2" PAINTED GYP BD ON BOTH SIDES; EXTEND TO ACOUSTICAL CEILING WALK-IN GENERAL NOTES COOLER ALL OTHER WALLS ARE EXISTING TO REMAIN 1. SWING & FORCED OPEN DOORS SHALL MEET THE REQUIREMENTS OF NEPA LIFE SAFETY ❑� d ❑❑ CODE 2012 EDITION CHAPTER 7.2.1.4 AND THE FLORIDA BUILDING CODE 5th EDITION (2014) ❑ Z ❑ 1008.1.2. 2, SELF CLOSING DEVICES SHALL BE PROVIDED ON DOORS 1N A MEANS OF EGRESS AND SHALL MEET THE REQUIREMENTS OF THE NEPA LIFE SAFETY CODE 2012 EDITION CHAPTER 7.2.1.8 CL AND THE FLORIDA FIRE PREVENTION CODE 5th EDITION (2014 ENCOMPASSING THE W m 2012 EDITIONS OF NEPA 1- & NFPA 101). _&FE W o rn CL0 {� FEC)o N 3. THIS BUILDING WILL BE A NONSMOKING FACILITY. -- oM 4. ALL WORK SHALL BE IN COMPLIANCE WITH THE BUILDING CODES, RECOGNIZED INDUSTRY CC G Z mN z( STANDARDS, CRAFTSMANSHIP STANDARDS IN THE AREA, AND ALL MANUFACTURER'S Wod 04 RECOMMENDATIONS. ow U- AHU Q Q 5. FLOOR FINISHES ON BOTH SIDES OF A DOOR SHALL BE LEVEL FOR A DISTANCE EQUAL TO pE:l o THE WIDTH OF THE WIDEST SINGLE DOOR (DOOR ON BOTH SIDES): ® (� 0 a) ° Z CD 6. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. L1j m n `~ �-' v REPORT ANY AND ALL DISCREPANCIES TO THE ARCHITECT/ENGINEER. PRIVAT OFFICE © � .- > °�� r °1' c Lij 7: CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL FIRE-RESISTANT-RATED WALLS (AND OFFICE = C.� *- co) r NUJ CORRESPONDING FIRE-RESISTANT RATINGS) INCLUDING FIRE BARRIER WALLS, SMOKE ® '� O" " ° 0 � i I r�N N '0"a BARRIER WALLS, FIRE PARTITIONS, IRE WALLS, AND SHAFT ENCLOSURES EITHER BY KITCHEN WOMEN'S o MENS ❑ O Q °') 0 C00 C INSTALLING SIGNS OR BY STENCILING IN CONCEALED SPACES THE FOLLOWING: C • M rn (D U-U- ( ) HOUR FIRE AND SMOKE RATED BARRIER - PROTECT ALL OPENINGS. TOILET TOILET IDENTIFICATION SHALL BE SPACED NO MORE THAN TWELVE (12) FEET ON CENTER WITH I A MINIMUM LETTER SIZE OF TWO (2)2 INCHES IN HEIGHT ON A CONTRASTING BACKGROUND 8. DO NOT SCALE DRAFTING, REPORT ERRORS IN DIMENSIONING TO ARCHITECT BEFORE PROCEEDING WITH WORK. ------ �€ FRAMING NOTES: 71'-51, 0 UNISEX o 1. PROVIDE FIREBLOCKING AND DRAFTSTOPPING IN PARTITIONS PER FBC 717. 8 2. EXPOSED INSULATION MATERIALS INSTALLED SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN ('� 25 AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 450 AS DETERMINED IN ACCORDANCE WITH / TOI LET PROVIDE THIN-SET STONE/TILE j N ASTM E 84. VENEER; REMOVE EXISTING GYP BD m .= N 3. CONCEALED INSULATION MATERIALS INSTALLED SHALL HAVE A FLAME SPREAD RATING OF NOT MORE4& REPLACE WITH TILE z w J II - m --� THAN 25 AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 450 AS DETERMINED IN ACCORDANCE UNDERLAYMENT SHEATHING Q w WITH ASTM E84. I -- �\�� ------ w � 4 � 4. PROVIDE WATER RESISTANT GYPSUM BOARD AROUND PLUMBING FIXTURES AND WALLS TO RECEIVE PRIVATE -- ----- z Q CERAMIC TILE EQUAL TO USG'S FIBEROCK'S BRAND AQUA-TOUGH INTERIOR PANELS.GYPSUM z w WALLBOARD PRODUCTS MUST BE RATED FOR WET LOCATIONS IN ACCORDANCE WITH THE TILE COUNCIL OF NORTH AMERICA(TCNA)HANDBOOK. GREEN BOARD IS NOT APPROVED FOR TOILET ROOM DINING (-__ ______ m LOCATIONS. I I U 5. PROVIDE P.T.WOOD BLOCKING IN WALL AS REQUIRED TO SUPPORT TOILET ROOM FIXTURES,ACCESSORIES, _ SHELVES&CABINETS,WALL MOUNTED TELEVISIONS AND FIRE EXTINGUISHERS. COORDINATE LOCATIONS o Q I I n OF CEILING&WALL MOUNTED TELEVISIONS WITH TENANT IN FIELD. U I � 6. PROVIDE R-11 SOUND ATTENUATION BATT AROUND THE TOILET ROOM. 7. PROVIDE EXIT DOOR TACTILE SIGNAGE READING: "EXIT". SIGNAGE SHALL COMPLY w/ANSI/CABG A117.1; I MOUNT 60"AFF TO CENTERLINE OF SIGN, f i I REMOVE EXISTING ACOUSTICAL I I 8. STUD GAUGES LISTED AREA MINIMUM. CEILING AND RAISE CEILING OVER I I I BAR 24" & PROVIDE NEW EPDXY PAINTED GYP BOARD CEILING SERVER AREA I I I I I II I I iI I I I II I I 31-51 D I CLEAR DAR I I I I I I I I f I I I FE -- --------I II I NEW I I I DINING SEATINGNQUET TTO MATCHDINING II I EXISTING I DISPLAY CASE BY OWNER 3'-8'' o ¢ `— .NEW KNEE WALL TO I CLEAR a u MATCH EXISTING I I REMOVE EXISTING SERVER I BAR.AND INSTALL NEW BAR. I I o TO MATCH EXISTING AND PROVIDE NEW BAR TOP �� IT I � I r�t� � � I ----- 11 HOSTESS STAND BY OWNER CL rx 11 Of II----- ----- - JI NEW BANQUET & --------------- ---------------I o 0 SEATING TO MATCHLi EXISTING 3 Z X V) o 00 N ZZ 1 U c cli NEW KNEE WALL TO a � z MATCH EXISTING ENTRYM OSTESS 0 a W o w i = ozwLLJ REMOVE EXISTING ELEVATED W, a cn z PLATFORM UNDER SEATING; L--------- --------J z Dw, Z w w PATCH & REPAIR FLOOR TO MATCH EXISTINGcr a a o DRAWN BY: CAS �W � w 6:2 L) 0 CHECKED BY: CAS ora 17'-1 „ 17'-48„ 17 -48„ 17'-3 „ o w_ DATE: 11 -10-15 "00MIS -1N p W.8 j I OUTDOOR �I REMOVE EXISTING SINGLE �, G. `jl a o o z 0o PROVIDE PANIC HARDW RE a� � 0 STOREFRONT DOOR; `60�JR- "' °° o W o ON EXISTING DOOR S EAT)N G & PROVIDE SINGLE WOOD y z ~ SHEET Zoo DOOR w/PANIC HARDWARE; MODIFY 0 a o STOREFRONT GLASS AS REQUIRED = tea (PROVIDE TEMPERED GLASS ADJACENT - 0 Z TO DOOR) > cn w w m � zw z } J a FLOOR PLAN � Vi G NU' x V) A 2 X �$ Z SCALE: 1/4"= 1'-0" w c� J WoW � _ Z �� � v) wn. w w=x o �w