Loading...
1668 E PARK TER 2016 HVAC 11 SS% CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-SS14 JOB INFORMATION: Job ID: 16-MECH-1 53 Job Type: MECHANICAL HVAC ONLY Description: 1 CLI 1 AHLI 3 TONS Estimated Value: $4,507.00 Issue Date: 1/21/2016 Expiration Date: 7/19/2016 PROPERTY ADDRESS: Address: 1668 E PARK TER RE Number: 172020-0314 PROPERTY OWNER: Name: MARVIN JR, MARION F & SONIA M, Address: 1668 E PARK TER GENERAL CONTRACTOR INFORMATION: Name: DAVID GRAY HEATING AND AIR INC Address: 6491 S POWERS AVE RYAN C ZABINSKY Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $24.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $107.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: 100 91, 4 9 —PERMIT# PROJECTVALUE $ 446'-b-I.,36- ARI# 90'7c2/9 I REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratin2 Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity 0 C) Seer Rating __:T ::: BTU's Per Unit_5�� Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Q1 ets of plans) Fire Standpipe QL ets of plans) Underground Fire Main Va As of plans) Fire Hose Cabinets QU !ts of plans) Commercial Hoods Qu., ts of plans) Fire Suppression Systems Qu, ts of plans) FIRE PLACES Prefabricated Fireplace Qty_ Gas Piping Outlets BTU's ALL OTHER GAS PIPING Quantity of Outlets #Vented Wall Furnaces b-T—ITS #Water Heaters OTHER: Permit becomes void if work does not commence with: six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correez. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the pnMsions of any other state or local law regulation construction or the performance of construction. Property Owners Name �SOC'N I CA- lf_�)a rt/i n Phone Number goq,2 _bprU j j) - -rivig , /q_,7aeo Mechanical Company , 5� A I p,- —Office Phone Wq� '761-1 t Fax Ya 4- Co. Address: 6P 4q I _P0 Lkw e- city State Ft-- Zip 3-221'7 License Holder (Print): _M 31 State Certification/Registration# Notarized Signature of License Holder R40 N Notary Public State of Florida efbwme��s dA of 20 LaSheicawilson %T/ My Commission FF 180366 ignature of Notary Public CIL-- Expires 01/04/2019 of tv Ei 3 C E RT I F I E DD www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 8072181 Date: 1/19/2016 Product: Split System: Heat pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HCE436A**31 Indoor Unit Model Number: FB4CNP036L Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER Series name: 14 SEER PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 33000 EER Rating (Cooling): 11.70 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh) @ 47 F: 33800 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh) @ 17 F: 21000 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate� DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no,responsibility for, the pro duct(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS ial and Thi Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,persol s ntial reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;dissl confide aminated: entered'nto a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING,HEATING, personai and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we mak,life beu,r- and enter the AHRI Certified Reference Number and the date on which the certificate was issued, —I which is listed above,and the Certificate No.,which is listed at bottom right. [CERTIFICATE NO.: '30976933254934334 @2014 Air-Conditioning, Heating, and Refrigeration institute