Loading...
2211 ALICIA LN - HVAC (2) y\J' -S ' CITY OF ATLANTIC BEACH y� 800 MINOLE j " " "ATLANTIC BEACH SE ,FL 32233 ROAD INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 ]OB INFORMATION: Job ID: 15-MECH-2085 Job Type: MECHANICAL HVAC ONLY Description: 1 cu 1 ahu 5 tons Estimated Value: Issue Date: 9/2/2015 Expiration Date: 2/29/2016 PROPERTY ADDRESS: Address: 2211 ALICIA LN RE Number: 169519-0745 PROPERTY OWNER: Name: DUTTERA TRUST Address: 2211 ALICIA LN 2211 ALICIA LANE GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315 SIXTH AVENUES QA WILLIAM J DONOVAN Phone: 904-241-3785 PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $40.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 TotalPayments: $123.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax(904) 247-5845 10B ADDRESS: D .\l C ( 1 �?� . PERMIT# PROJECT VALUE $ LI ARI# i 6C( REQUIRED Air Handling Equipment Only .Air Handling Unit & Condenser Condenser Only JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total. CFM REQUIRED tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air. Conditioning: Unit Quantity! I Tons Per Unit Seer Rating Heat: Unit Quantity 1 BTU's Per Unit a� REQUIRED Duct Systems: Total CFM +IRE PREVENTION uanti (Requires 3 sets of plans) Fire Sprinkler System Q �' R uires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of flans) Underground Fire Main Value a Fire Hose Cabinets Quantity Quantity (Rquires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of lane plans) +IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators I.LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: emit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that l have read its application and know the samc to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance construction. 'roperty Owners Name Du + c - P hone Number r�J(/(� ,4echanical Company V ~` Y1 't 6NN C Office Phone 44 i 11 ax ;o. Address: l (kh 11,.j t. ‘-o u 4'l'` City 3 L--Stated/ lip 2aEO license Holder(Print): ��.1�`\'a"� ��b�— State Certification/Registration#Gb4,15 ''iq 71,1 1 Votarized Signature of License Holder Gtlittl.;---, ,. , efore me this ,a day of Sc.- ) 20� 110lxQernlQ ',et. �Pd 1n�1 N41 Dopag ____ La,�lmr sohdx� (vj}uolssnuoO Signature of Notary Public Dlo1 avH3la / � .�. .�.� Job: Project Summary Date: 8(28(15 Entire House`n►lrightStDf�. Sy: Brandon Zaharie Donovan Heat& Air 315 6th rive south,Jackson: Vllle 880011,FL 32250 Phone:241-3785 Emelt:brandonatdonovettac.c w - \ Project Information For: DUTTERA 2211 ALIXA LANE,Atlantic Beach, FL 32233 Notes: Desi n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions 39 °F Outside db 95 °F Outside db 68 eF Inside db I g 29 °F Design TD 20 °F Design sign T TD Daily range L Relative humidity 50 % li Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing 23790 Btuh Structure 25120 Btuh Ducts Structure 11327 Btuh Ducts 16371 Btuh C 4 Btuh Central vent (52 cfm) 1134 Btuh Central vent cfm) 164 0 Btuh Blower 0 Btuh Humidification ification n 0 Btuh Equipment load 36761 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 42624 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1876 Btuh Ducts 3876 Btuh 866 Stuh Heating Cooling Central vent (52 cfm) 1 1866 Btuh Area(ft') 2160 2160 Equipment latent load Volume(ft°) 19440 19440 Air changes/hour 0.38 0,16 Equipment total load 50191 Btuh Equiv.AVF (cfm) 124 52 Req. total capacity at 0.70 SHR 5,1 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade Trade 4TWR4060 Model 4TWR4060 Cond ARI ref no. 7419158 Coil TEM4A0C60 ARI ref no. 7419158 15 SEER 8.5 HSPF Efficiency Heating 43982 Btuh Heatin input Sensible cooling 18849 9tuh g 62519 Btuh @ 47°F Latent cooling Heating output 27 °F Total cooling 62831 Btuh Temperature rise 2094 cfm Actual air flow 2094 cfm Actual air cow 0.060 cfm/Btuh Air flow factor 0,050 cfm/Btuh Str flow factor 0 in H2O Static pressure 0 in H2O Static press Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 5th Ed. -4k- w- i tvre Bligh-SuttelD Unlvereat 7.1.01 RSU05588 201r•Aug•7.B 51:08'50 CIUsnrstSales\Documents%NrloHRatt HVAC15 TON,rup Calc=MJB Orlerttetion N range I