Loading...
1545 FRANCIS AVE KITCHEN REMODEL fra f,IS\ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RESIDENTIAL ALT/OTHER MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-RAAR-412 Job Type: RESIDENTIAL ALTERATION Description: INTERIOR REMODEL - KITCHEN Estimated Value: $2,500.00 Issue Date: 2/25/2016 Expiration Date: 8/23/2016 PROPERTY ADDRESS: Address: 1545 FRANCIS AVE RE Number: 172284-0000 PROPERTY OWNER: Name: Roys, Mary Jane Address: 1545 Francis AVE PERMIT INFORMATION: FEES: PLAN CHECK FEES $31.25 BUILDING PERMIT FEE $62.50 STATE DCA SURCHARGE $2.00 STATE DBPR SURCHARGE $2.00 Total Payments: $97.75 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. City of Atlantic Beach 'A Building Department APPLICATION NUMBER 800 Seminole Road (To be assigned by the Building Depart]]ment.) flantic Beach, Florida 32233-5445 Phone(904)247-5826 * Fax(904)247-5845 IRA r.;J19 E-mail: building-dePt@coab.us t ro City web-site: http://www.coab.us F[Date roupte��d: APPLICATION REVIEW AND TRACKING FORM Property Address: S4S! FRf�ADus �)v Buildi i ent review required Ye No i:�'Q gi Applicant: C) LAD Zoning Project: Tre Administrator Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Florida Dept. of Environmental Protection of Permit Verified By Date Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI�'ATION STATUS Reviewing Department First Review: pproved. []Denied. (Circle one.) Comments: EBUILDING D PLANNING &ZONING Reviewed by: :121h� TREE ADMIN. Date:c)// Second Review: DApproved as revised. IDe d. PUBLIC WORKS Comments: El PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ElApproved as revised. OlDenied. Comments: Reviewed by: Date: Revised 07/27110 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH I OFFICE COPY 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 16 - RARR -4 ( 2: Job Address: Number: Legal Description Do Ploor Area of' S(�TF_t. Parcel# SqTt Valuation of Work S —Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): New Addition � Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s) (circle one): Commercial (P�esidenti No If an existing structure,is a fire sprinkler system installed? (Circle one): es No N/A Florida Product Approval# For multiple products use produ&_—app_ro_va_Ffo—rm— Describe in detail the type of work to be performed: U PrODerty wner Information: Name:_,A A-," 4 Address: City 02:t&n, ADA Stat ip Phone -2- 3 E-Mail or Fax# (Optional) 'h Contractor Information: CONTRACTOR EMAIL ADDRESS: Company Name: Quali g Agent: Address: State Zip Office Phone Job Site/Contact er Fax 4 State Certification/Registration# Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Addr Bonding Company Name and Addres Mortgage Lender Name and Add- s 4pplication is hereby made to obtain apermit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be peiformed to meet the standards of all laws regulating construction in thisjurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandonedfor aWeriod ofsix(6)months at any time after work is commenced. I understand that separate permits must be securedfor Electricat Work,Plunibing, Mins, ells,Pools, Furnaces,Boilers,Heaters, Tanks andAir Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Ihere certify that I have read and examined this,a lication and know the same to be trite and correct. A It provisions of laws and ordinances govern in this ,�Iwork will be cmnplied with whether eci 70 herein or not. The granting of a perinit does not presume to give authority to violate or canc�l the %, g provisions of any otherfederal,state, or local aw regulating construction or the pe�fo�mance of construction. Signature of Owner `�o L(S .3rint Name A#g U Signature of CoZntractor . . . . . ....... ............................................................ Print Name .j ................................... .................................................................................................. 3ef3 e Before ine his f this —Day of 20 SSION 0 FF 924111 19 Zotary Public Pubic U W B Notary Public Revised 01.26.10 OFFICE COPY ATLANTIC]REACH ITY OF OWNER / BUILDER AFFIDAVIT i- FLV�-MMWA STA—tUTES,- CHAPTER 1489, FLO–Riu–A' STATUTES, PART "CONSTRUCTiON 11r%NTf!1=!%'G"RE--UtRES 0104NIERI BUILDER TO ACKN'O%"&'-DGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 499.103(17).FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. You HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION To T-HAT LAW, THEEXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUS SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE-OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU 14AVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE,TTIE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE,WHICH IS IN VIOLATION,OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATION& IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCE& ft. INtURY LMEtLITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE, THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. Iff. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO$6,000 PENALTY UNDER FLORIDA STATUTE NO. 455-228(1� AN-OCCUPATIONAL LICENSE-IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY 'CERTIFICATE OF COMPETENCY' OR THE FLORIDA 'CONTRACTORS CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. TELEPHONE THE BUILDING DEPARTMENT(247-5826)IF IN DOUBT. V.ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. S— ADDRESS PHONE NUMBER P7TNAME1 f7� SIGNATURfj 0 DATE Before me this n rl _nM day oLTQngjjZV 20414 in the county of Duval,State of Florida,has personally appeated herin by himself I herself and affirms that -11 statements and declarations are=truend a,,,,nte, of a Notary Public at Large,Statef )C, I C ounty SHELLEY SHAFFER Notary Pubk-State of FkwW& E3 Prdud kJn#katbn- My COMM.Expiret Nov it 2017 Coallrdilillon#FF 39054 �a// "�'& Notary Signal., A F:MLDG/0wna-BVAdw Aft&va,REVISMV1612009 .......... ------- ................ ............ .......... -- ------------------------------------- ..............I'll, ---------------- .........."I'll", .................. ... .... ........................ .................................. --------------------- "I............ ..... ............ �.Pj' Structures Inspection Report 1545 Francis Avenue Atlantic Beach, FL 32233 Duval County, Florida M I rn m 0 -no m ic 3u: -on 00 z z 4 m '0 0 C) CZ) MW on r4o > Z > 0 z r- X z 0 m Fares E. T®Rnous FL P.E. No. 6378 13"Dunns Lake Dri Jacksonville,FL 32218 (904)234-06$ ebruary 17, 2016 OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63 784 1322 Dunns Lake Drive*Jacksonville, PL J2218*Uell:(904)2J4-0657-e-mail:Jh1annousghotmail.com February 17, 2016 To: Mr. Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach FL 32233 Re: Structures Inspection Report 1545 Francis Avenue Atlantic Beach FL. 32233 Dear Mr. Jones, I am pleased to submit this Structures Inspection Report for the single family residence located at 1545 Francis Avenue, Atlantic Beach, FL 32233. This report documents the findings and professional engineering opinion based on the on-site reconnaissance findings conducted on February 14, 2016 upon the request of the property owner Ms. Mary Jane Roys. The Location Map and front elevation of the aforementioned property is shown in Figure 1 of Appendix A. The scope of services is to visually inspect two partition walls to determine if they are of the load-bearing type or of the non-load-bearing type. This request was made by the owner of the property, Ms. Mary Jane Roys, who intends on removing two partition walls in an effort to remodel the interior of the house. The inspected house is a single story with a floor area of approximately 765 ft2. The exterior bearing walls are constructed from 6 x 8 x16 standard concrete Masonry Units (CMUs) providing the structural strength to resist roof loads as well as lateral wind loads. The Interior partition walls mainly constructed from 4" partition cement masonry 4 x 8 x 16 partition blocks in a running bond pattern with %" mortar joints. Figure 2 in Appendix A shows the floor plan of the property located at 1545 Francis Avenue. It also shows the location of the subject partition walls. The following is a brief summary of the inspection findings: 1. Partition Wall 1: Partition Wall 1 (PW1)was removed prior to field inspection on 2/14/16 and without consultation or consent by the Author of this Report. Therefore hands-on inspection was not performed and only visually examined the photographic records provided by the owner depicting PW1 prior to its removal. Exhibit I shows the north elevation of PW1 after the removal of the 1/4" sheetrock fascia exposing the 1%"x 1/4"wooden support strips. In addition, it shows the original finished top section of wall. Exhibit 2 shows timber framing on top of PW1 after the removal of the %"plywood cover boards. Visual inspection of photographic record indicates that the top section of the wall is not constructed as a structural load bearing wall and it does not support the roof beams (PW1 runs in between and parallel to roof beams). Exhibit 3 shows the comer connection to bearing wall and Exhibit 4 shows the kitchen floor after PW1 was removed. For Exhibits 1 thru 4, See Appendix B. For approximate location of PW1 before it was removed and photo view depicted by each exhibit, see Figure 2. OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63 784 2 JJZ2 Dunns Lake Drive,Jackyonville,PL J22hy-Cell:(Y04)234-0657,e-mail:jhtannousg1jotmail.com MMMMMMMMMM� 2. Partition Wall 2: Visual inspection of Partition Wall 2 (PW2) revealed it was of similar construction to that of PWI. Exhibits 5 shows the north elevation of PW2 prior to the removal of the sheetrock fascia board. Exhibit 6 shows the 7'-6"± section of PW2 after removal of the sheetrock fascia. Hands-on inspection showed that PW2 of similar construction to that of PWI. The sheetrock fascia was completely removed off the PW2 section above the closet door as shown in Exhibit 7. Wall framing consisted of 2x4 stud sect,ions @ 16"spacing resting on top of 2x4 cover plates. A stud finder was used to confirm the 16" spacing of the studs concealed by the sheet rock shown in Exhibit 6. Upon visual examination of a typical stud framing member connection to the roof beam as shown in Exhibit 8, it indicates that the timber studs were nailed to the side of the 3x6 roof beam to provide support for the sheetrock fascia and not to structurally support the roof beam. Similar to PW1, the roof beams span parallel to PW2. Therefore and based on the above, it is my Professional engineering opinion that PWI and PW2 are of the non-load bearing type and do not provide structural support to the roof beams. 2.Window in East Wall of Room 1: The window along the east wall of Room 1 was removed prior to site inspection on 2.14.16 and without consultation or consent by the Author of this Report. Visual inspection of performed work showed that the window frame was removed and opening was filled in with standard concrete masonry blocks of similar size and running bond pattern to that of existing blocks. Visual inspection of the work indicates that was of good quality and does not seem to compromise the structural integrity of this load bearing wall. I appreciate this opportunity to be of service to you and I look forward to maintaining our professional relationship. If you have any questions regarding the contents of this report, please do not hesitate to contact me. Sincerely, A/V 5 84 Ili IV OF R St g1heer Florida License No. 63784 OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63 784 3 WZLhinns Lake Drive*Jacksonville,PL 32216-Celt:(YU4)234-0637*e-mail:jhlannous(a,)hotmaiL com -- APPENDIX A FIGURES OFFICE COP� Fares E. Tannous, P.E. — Florida License No. 63 784 4 IJ22VunnsLak,e Drive*Jacksonville,PL Mid Cell:(YO4)2J4-06-)Z*e-mail.,jhlannousGa)holmall.com 1545 Francis Avenue a----__Atlantic Beach, FL 32233 Site Location ME 1545 Francis Avenue, Atlantic Beach, FL 32233 FIGURE I T OFFICE COPY 6-17-t 24'-LY'-t rb 'T——————— ——————— Window Roof Pitch lRoof Pitch N rn M zr Cr Q1 -- Z rn tn :30 C) 0 DO 0 0 Partition Wall I (PWI) rn Ln X t6r, (A 1+ rn 7-6"�± --———————— P 2 )our Partition Wall 2 (PW2) rn X 03 zr m Q) :rj Cx fb CLOSET CLOSET (b ----- LL N X zr Cr 00 ;;: tn DO NJ Window Window OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63 784 1322 Vunns Lake Dilve Jacksonville,PL J221tY*Cell:(YU4)234-U657-e-mail:jhlannous(a_)hotmaiLcom APPENDIX B LIST OF EXHIBITS OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63784 7 IJ22L)unns Lake Drive*Jacksonville,1,L J2214Y*Cell:(904)234-00.)1-e-maii:jhtannous(a.)hol7nall.com EXHIBIT 1 —North Elevation of Partition Wall I Prior to Removal EXHIBIT 2—North Elevation of Partition Wall I Prior to Removal OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63 784 8 I J22 Vunns Lake L)rive*Jacksonville,PL 322far*(;ell:(Y04)2J4-0657*e-mail:jhtannous(a_)hotmail.com EXHIBIT 3—Location of Partition Wall I Connection to Bearing after Removal of Wall EXHIBIT 4—Location of Partition Wall I Connection to Floor after Removal of Wall OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63 784 9 1322 Vunns Lake Drive*Jacksonville,I'L 52216-cell:(YU4) ,M-057-e-mail:jhtannous(a_)hotmail.com EXHIBIT 5—North Elevation of Partition Wall 2 Prior to the Removal of Sheetrock Mm. EXHIBIT 6—North Elevation of Partition Wall 2 after Removal of Sheetrock OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63 784 10 1322Dunns Lake Drive*Jacksonville,PL J2214Y Cell:(YU4)2_44-U657 e-mail:jhtannousQ"otmail.com EXHIBIT 7—North Elevation of Partition Wall 2 above Closet Door after Sheetrock Removal %w EXHIBIT 8—Framing Stud Connection to Roof Beam(Non-Load Bearing) OFFICE COPY Fares E. Tannous, P.E. — Florida License No. 63 784 1522 Lhinns Lake Drive*Jacksonville, PL J221 *Cell:(904)234-06.3 7 e-mail:jhlannousghotmaii-com .......................... C��A EXHIBIT 9—Masonry Blocks Fills in Field after Removal of Window (Location: East Load Bearing Wall)