Loading...
1637 ATLANTIC BEACH DR NEW HOME DOCS a. le CITY OF ATLANTIC BEACH SS J 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 X1319 SINGLE FAMILY DWELLING NEW MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFR-269 Job Type: SINGLE FAMILY RESIDENCE Description: NEW HOME-DRIVEWAY Estimated Value: $255,817.00 Issue Date: 2/24/2016 Expiration Date: 8/22/2016 PROPERTY ADDRESS: Address: 1637 ATLANTIC BEACH DR RE Number: None GENERAL CONTRACTOR INFORMATION: Name: TOLL BROS.,INC Address: 250 GIBRALTAR RD STEVEN R MERTEN Phone: - - PERMIT INFORMATION: PUBLIC WORKS: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. All silt must remain on-site during construction. Roll off container company must be on City approved list and container cannot be placed on City Right- of-Way. (Approved: Advanced Disposal, Realco, Republic Services, Shappel's and Waste Pro.) Full right-of-way restoration, including sod, is required. FEES: ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $473.73 UTIL REV RESIDENTIAL BLDG $50.00 1$MDlNQ~UNT)�-►IjBN ACCORDANCE"IRAF)L CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. `S, CITY OF ATLANTIC BEACH #, 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 STATE DCA SURCHARGE $14.21 STATE DBPR SURCHARGE $14.21 SEWER SDC-SYSTEM DEV CHG $4,050.00 WATER CONNECT/TAP & METER $370.00 WATER CROSS CONNECTION $50.00 WATER SDC-SYSTEM DEV CHG $1,140.00 Total Payments: $7,209.60 a PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. i BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH OFFICE COPY 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: 1637 Atlantic Beach Drive-, Atlantic Beach FL 32233 Permit Number: /G f SFR-cg9 Legal Description Lot 7 Atlantic Beach Country Club Unit 1 67-52-08-2S-29E.152 Parcel Floor Area of Sq.Ft. Sqq.Ft Valuation of Work$ 255,817 Proposed Work heated/cooled 2,125 non-heated%ooled 540 Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/pro posed structure(s) (circle one): Commercial Residential If an existing strucure,is a fire sprinkler system installed? (Circle one): N/A Florida Product Approval # See attached For multiple products use product approval form Describe in detail the type of work to be performed: New Residential Construction Property Owner Information: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May AvenueS U V E City Ponte Vedra State FL Zip 32081 Phone 904 217-0739 J E-Mail or Fax#(Optional) arogers@tollbrothers.com i Contractor Information: CONTRACTOR EMAIL ADDRESS: aro ers toll q o ers — 4 206 Company Name: Toll Bros., Inc. Qualifying Agent: Steven R. Merten ' Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904 217-0739 Job Site/Contact Number 904 386-6472 Fax# State Certification/Registration# CGC 1510225 Architect Name&Phone# Engineer's Name &Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6)months at any time after work is commenced. 1 understand that separate permits must be secured for Electrical Work, Plumbing, Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specid herein or not. The grantin of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. Signature of Owner Signature of Contractor Print Name Steven R. Merten Division Sr.Vice President Print Name Steven R. Merten Before me Before me, this 3PPa Februa 2016 this 3 a of Februa 2016 Notary Not lic Revised 01.26.10 MELISSA LIEBERrAAN MELISSA LIEBERMAN MY COMMISSION#FF055605 os tember 18.2017 MY COMMISSION#FF055605 '9'foFe�°e; EXPIRES Sep :a' ._ C - �_ FloridaWaryservice.com "9.'FovF ?; EXPIRES September 18.2017 407)398-0153 1'107 398-0153 FloridallotaryService.com DO NOT WRITE BELOW- OFFICE USE ONLY App iea e Co es: 2010771 ORIDA BUILDING CODE Review Result (circle one): Approved Disapproved Approved w/ Conditions i Review Initials/Date: /77 Development Size Habitable Space 57 S.F. Non-Habitable 1? 3 S. Impervious area Miscellaneous Information Occupancy Group 13 Type of Construction V13 Number of Stories Zoning District 61,6 61,b Max. Occupancy Load Fire. Sprinklers Required Flood Zone x Conditions/Comments: perm-j 16 ` SP9-- 267 NOTICE OF COMMENCEN1-jeAT OFFICE COPY State of: FLORIDA Tax Folio No. 169505-1090 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 7 Atlantic Beach Country Club Unit 1 67-52-08-2S-29E.152 Address of property being improved: 1637 Atlantic Beach Drive ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD. HORSHAM,PA 19044 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: Contractor: TOLL BROS.,INC. poll Address: 160 CAPE MAY AVE. PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN Address: 160 CAPE MAY AVE.PONTE VEDRA,_EL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): 06/30/17 THIS SPACE FOR RECORDER'S USE ONLY OWNER / Signed: Date: Before m is (D day of f7C71 in the County of Duval,State Doc#2015237736,OR BK 17337 Page 582, Of Florid as personally appeared Ski h 1 Number Pages:1 Notary Public at Large,State f Flpri j County of Duv Recorded 10/15/2015 at 01:58 PM, My commission exp2922 C Ronnie Fussell CLERK CIRCUIT COURT DUVAL Personally Known: or COUNTY Produced Identifica , RECORDING$10.00 "�MELISSA L OMMISSION#FF055605IRES September 18.2017 FloridallotaryService.com -- 0 tJ O b '17 YCD f�D Na n o c. tr°Q y o o CD = d (IQ a . CD UQ cr P CD CD m Ln cL En CD CL ° O CD W ° cmc o �• w � � O C 71 ti ti -u �c n -� �? ° o a 00 n ° G CD t1i CD CCCL y (D < w o o , Cl- CD UQ n � C o v o Y o c o o w CD ^. cr o tbCD z 5 CD o r O Q C W CD H N O W " z 0 0 "o cn `••" °7 x N Cr1 r H a :5- b ) CD G1 Y < < < CDD a ° 0 0 0 �' O f* rJ UQ CL CL CD G7 X' o to o CL O f. < H CL d o c o a o a. cD d cuCL CD• y '+ � 5 o y 0 o a ° o C ' K � H a r (Da O W cn cn cn N N z Z r '•*� E O H ° n o UQ x CL C c o = c0 CD O oQ rr r r rr r TI� S. = � 00 d CT 0o O oN, o W N O rn A O tA N = 00 N "n N N CD r N O to tr a, N O� � N W r \m ° 'O �l 0 � � A w N .- O � oo J O� v� J� w N --• � = � v oo J O� v� � w N -- n o ~ � z � rz PVzL4r� zz caz o ° n o o m o ova a _ ° o a "o O SCD CD (D = CD =� Z v c`o va ,Z3va cro o ¢ zs va ° ° Cr o. tt �, s oh = o o CD n cc X C w .� CSD CD. p, CD Uma A: °1 CD Una n U ° r" c d°a w77 CQ as °o o -n - Cl- s � o x x C-' cn �• �' 0. 0. 7 ° UQ Ua 0. 0. n n ca- n n Ua CA N Ua UQ X CoUa 0. 0. NV) f1- 3 CD CD w S S C O a Up UQ O CACD n C � O r O z z z zzz + z z z z w o' 0 -n C CD ° -n ITI -n r r r r r r r r r00 r r N w N A oo O O N wZ-Al00 I�j N w J w J N A W N CD 77 Go N i ° n a; ■ N xj N «-• 0 N ao ztl7 Q � v�"y1 wjcvo� - -d �tiO ws_ l ON cn A w N nyaG i4 -.4 a-,O_ on Ao w' N - M� � ; O ; nPdtrI -3QM mor 08 o o n o ao r ao "C� Ae vai n ?. 0' O kyr � ° o o °'- �' `; m o z n coo w �' o ff o o Lei H �H. o o FCri1 0 (D z H � ^- OCD CD c � � eD n o 0 0' 004 H -e .d 0 C O. N O� a y _ a4 5* CD o o ja, CD� CDw a `D w cf Do O rn N .•, CD CD � � n CD O N. O En a � 0 o CD 0 w � a 04 0 m 'O° ITI En cnc 0 O N EnX � � y CD a z r o. O O . c2 Ln ° r. A N o. O O O 0 0 C y o. •Lj '17 'z7 b b '� w C> .r ^- 41. w a4 U4 ti ti C 0. 0• cet U4 U4 : O A R / ƒ Ln ° \ / E R k R S ° § > \ ° K \ CL \ � \ / \ / / ƒ « e .. e ] CD n n CD < n = t & \ ] 8 < Q @ 0 \ 2 2 @ / 2 / ® 2 n = ƒ CN 2 / ) a / f / \ / CD ƒ § / g ± Q CD \ ƒ \ / CD / \ 0 / ƒ / 7 / CD § x \ / \w D� c CD / / " r q .. § � m f \ / CD \ E � / 0 ¢ / C \ « n § ° ] $ 0 f � m / ƒ \ OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Builder Name: Toll Brothers Project Name: Cumberland 2125 Left W Permit.Office: Atlantic Beach Street: 1637 Atlantic Beach Dr.(Lot 7 AB) Permit Number: City,State,Zip: Atlantic Beach ,FL, Jurisdiction: 261300 Owner: Toll Brothers Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(2314.8 sgft.) Insulation Area a.Frame-Wood,Exterior R=19.0 2133.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 181.50 ft2 1 c.N/A R= ft2 3. Number of units,if multiple family ft2 3 d.NIA R= 40 sgft.) Insulation Area a.Under Attic(Vented) R=38.0 1913.00 ft2 i 5. Is this a worst case? N0 R=19.0 212.00 ft 2125 b.Under Attic(Vented) ft2 6. Conditioned floor area above grade(ft2) c.N/A R- Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 Area a.Sup:Attic,Ret:Attic,AH: Garage 6 425 7, Windows(267.0 sgft.) Description a. U-Factor: Dbl,U=0.33 267.00 ft2 SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency ft2 30.0 SEER:14.00 N/A b. U-Factor: a.Central Unit SHGC: ft2 c. U-Factor: N/A 13.Heating systems kBtulhr Efficiency SHGC: ft2 a.Electric Heat Pump 30.0 HSPF:8.20 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: 4.345 ft. 14.Hot water systems 0.300 Area Weighted Average SHGC: a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (2125.0 sgft.) Insulation Area EF:0.600 a. Slab-On-Grade Edge Insulation R=0.0 2125.00 ft2 b Conservation features b, NIA R c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 51.56 PASS Glass/Floor Area: 0.126 Total Baseline Loads: 55.55 Review of the plans and IRE ST�11 I hereby certify that the plans and specifications covered by specifications overed by this ti0, _" 0� this calculation are in compliance with the Florida Energy calculation indicates compliancero �o,•''' Code. with the Florida Energy Code. 1 Before construction is completed er. PREPARED BY: 'a - - O1�0"T�It P this building will be inspected for c71 DATE: compliance with Section 553.908 . Florida Statutes. ,,,a„.,•s�� I hereby certify that this building, as designed,is in compliance RGpf}. with the Florida Energy Cod . . BUILDING OFFICIAL: ---- ------ ----- OWNER/AGENT:._.. ._ . .._ ...... __-------- - -- DATE: - --- - - DATE: --- i - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as I certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage. test report in accordance with R402.4.1.2. I ! EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 1/712016 2:39 PM i E FORM R405-2014 PROJECT Cumberland 2125 Left W Bedrooms: 3 Address Type: Street Address Title: Lot# Building Type: User Conditioned Area: 2125 Total Stories: 1 Block/SubDivision: Owner. Toll Brothers PlatBook: #of Units: 1 Worst Case: No Street: 1637 Atlantic Beach Dr. Rotate Angle: 0 Builder Name: Toll Brothers County: Duval Permit Office: Atlantic Beach Cross Ventilation: No Whole House Fan: No City,State,Zip:- Atlantic Beach , Jurisdiction: 261300 FL, Family Type: Single-family New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Jr Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range V FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS l V Area Volume o Name -----------.. ._. Number -- -.._..---- - ---....----..--------------- - - 1 -Blockl 2125 21250 SPACES eArea Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated Number Name e ... -- --- 3 1 Yes Yes Yes Main 2125 21250 Yes 4 FLOORS Tile Wood Carpet ---- # Floor Type Space Perimeter R-Value Area -- - 0 2125 ft= 0 0 1 1 Slab-On-Grade Edge Insulatio Main 212.9 ft ROOF / Pitch Roof Gable Roof Solar SA Emitt Testred IDnsul.eck (deg) V # Type Materials Area Area Color Absor. Tested _. .. 1 Gable or Shed Composition shingles 2461 ft= 620 ft2 Medium 0.8 N 0.9 No 0 30.3 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC -^ 1 Full attic F%V/ Vented 300 2125 ft2 N N CEILING Framing Frac Truss Type # - Ceiling Type Space R-Value Area ���--- 1913 ft2 0.11 Wood 1 Under Attic(Vented) Main 38 2 Under Attic(Vented) Main 19 212 ft2 0.11 Wood i i Page 2 of 4 1/7/2016 2:39 PM EnergyGauge®USA-FlaRes2014 Section R405,4.1 Compliant Software FORM R405-2014 WALLS Cavity Width Height Sheathing Framing Solar Below V/ Adjacent Space R_VaIu�����Et-jn Area R-Value-EracticnWbsor-GtadeJA-_ #. .__Ornt_--J°-T00.23 0.6 0 V 1 W Exterior Frame-Wood Main 19 19 10 10 0 198.3 ft2 0 2 S Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft2 0 0.23 0.6 0 3 E Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.6 0 4 N Exterior Frame-Wood Main 19 76 9 10 0 767,5 ft2 0 0.23 0.6 0 5 20 2 9 0 181.5 ft' 0 0.23 0,01 0 W Garage Frame-Wood Main 13 DOORS I Storms U-Value Width Height Area # Ornt Door Type Space Ft In Ft-In - _ . -- None .6 3 8 24 ft2 1 W Insulated Main 2 21.3 ft2 V None 6 2 8 8 �/�/ Insulated Main WINDOWS Orientation shown is the entered,Proposed orientation. _ Overhang V Wall - Area De th Se aration Int Shade Screening # OrntID_ Frame Panes NFRC U-Factor SHGC p p - 1 y� 1 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 7 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 _V 4- 90.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 2 S 2 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 3 E 3 Vinyl Low-E Double Yes 0.33 0.3 72,0 ft2 10 ft 0 in 1 ft 0 in Drapes/blinds Interior 5 4 E 3 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 5 N 4 Vinyl Low-__ E Double Yes 0.33 0.3 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation - -- 9 ft 1 -- --- - - 540 ft2 510 ft2 64 ft .--F� INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 -_ .2446 5 1 Wholehouse Proposed ACH(50) .000318 1770.8 97.22 182.83 HEATING SYSTEM Efficiency Capacity Block Ducts # System Type Subtype 1 Electric Heat Pump Split HSPF:8.2 30 kBtulhr 1 sys#1 COOLING SYSTEM Efficienc Ca acit Subtype Air Flow SHR Block Ducts # System Typey --- J 1 Central Unit Split SEER:14 30 kBtulhr 900 cfm 0• 7 sys#1I I I 1/7/2016 2:39 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use __-_SetPnt Conservation g ------ - I _ ---- None / 1 Natural Gas Tankless Exterior 0.6 1 gal 60.9 gal 120 de SOLAR HOT WATER SYSTEM Collector Storage FSEC Collector Model# Area Volume FEF Cert # Company Name System Model# -- ----- -- - -- — --- ft2 None None DUCTS Air CFM 25 CFM25 HVAC# ----Supply-- --Return- ------- --- -- # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool - -ttic- -----425 ftx Attic 106.25 De- - - i 1 ✓ 1 A 6 fault Leakage Garage (Default) (Default) TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr May X Jun �Xj Jul [[X]Aug �Xj Sep ( ]Oct [ ]Nov H Dec [XI [[ ]] ki ( ] [ Ma Jun JulAugSep []Oct X Nov Dec Heating Jan (X]Feb Mar []Apr t y Jun Jul l Aug Sep [Xl Oct X Nov Dec Venting Jan [[ ]l Feb Mar [Xl Apr L May --.--- Hours Thermostat Schedule: HERS 2006 Reference 3 4 5 6 7 8 g 10 11 12 Schedule Type 1 2 --- AM 78 78 78 78 78 78 78 78 80 80 80 80 Cooling(WD) PM 80 80 78 78 78 78 78 78 78 78 78 78 78 78 78 7B 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 66 66 66 68 68 68 68 68 68 66 Heating(WD) AM 66 66 PM 68 68 68 68 68 68 68 68 68 68 66 66 8 68 Heating(WEH) PM 66 66 68 66 66 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Run Time Cooling System Type.. . . Supply CFM Exhaust CFM Fan Watts _ HR_V Heating System .............. . _ --.- - - ._.. . __.... 0% 1 -Central Unit 0 0 0 1-Electric Heat Pump None 117/2016 2:39 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the En e rgy Performance Index,the more efficient the home. 1637 Atlantic Beach Dr. (Lot 7 AB) , Atlantic Beach , FL, 1. New construction or existing New From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19,0 2133.30 ft= 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 181.50 ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 d.NIA R= ft2 4. Number of Bedrooms 3 Insulation Area 10.Ceiling Types 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1913.00 ft2 6. Conditioned floor area(ft2) 2125 b.Under Attic(Vented) R=19.0 212.00 ft2 c.N/A R= ft2 7. Windows'" Description Area 11.Ducts R ft2 a. U-Factor. Dbl,U=0.33 267.00 ft2 a.Sup:Attic,Ret:Attic,AH: Garage 6 425 SHGC: SHGC=0.30 NIA ft2 b. U-Factor, kBtu/hr Efficiency SHGC: 12.Cooling systems ft2 a.Central Unit 30.0 SEER:14.00 C. U-Factor: N/A SHGC: ft2 kBtu/hr Efficiency d. U-Factor: NIA 13.Heating systems SHGC: a.Electric Heat Pump 30.0 HSPF:8.20 Area Weighted Average Overhang Depth: 4.345 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems ! 8. Floor Types Insulation Area a.Natural Gas Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2125.00 ft2 EF:0.6 b.N/A R= ft2 2 b. Conservation features c.N/A R= ft None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building osr�. Construction through the above energy saving features which will be installed (or exceeded) ��, in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,; i ;,,,, ,, o based on installed Code cc p' ntfeatures. Builder Signature: Date: (�I' I'g N k ?t City/FL Zip: Tt.323 Address of New Home: I1p31 ani _ / '� i *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/7/2016 2:39 PM 9Y 9 Ener Gau e®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS:. 1637 Atlantic Beach Dr.(Lot 7 AB) Permit Number. Atlantic Beach ,FL, i MANDATORY REQUIREMENTS see individual code sections for full details. performance level(EPL) I 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy p display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and j ontains information indicating the energy performance level and efficiencies of components nonpresold residential buildings.The EPL display card c installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in Where required by the code official,an approved thirdons and hparty shall ia inspect alted in lcompon components and verify compliance.le to the ethod of construction. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code any time after creation of all penetrations of the building thermal envelope. official.Testing shall be performed at z i During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and I6.Supply and return registers,if installed at the time of the test,shall be fully open. I R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. 8402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. Id R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as.having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. ET Standards by either an energy rater certified in accordance with Section Duct tightness shall be verified by testing to Section 803 of the RESIN 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2, Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested ng he I to a dpressure or otherwise sealed during the test If he air handler.(25Pa)across te system,is not installed atlthettime of the test manufacturer's totalair leakage shall be less All than or equal to isters shall 3 cfm I taped or oth (85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. i Page 1 of 3 geO USA-FlaRes2014 -Section R405.4.1 Com 1/7/2016 2:39 PM EnergyGau FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) kage of no more than 2 percent of the R403.2.2.1 Sealed air handler. Air handlers l have a 19ufacturer's designation for an air lea i design air flow rate when tested in accordance with 3. I I R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.3 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., 1 I R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. I / hot p] R403.4.1 Circulating hot water systems`Me hot-water circulating Circulating when the system its Inotein useded with an automatic or readily accessible manual switch that can turn R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with Integral heat traps and having vertical pipe risers shall have heat traps installed on both the inets and d of atl lleast 3'/2 inlches(89rmm)nathe hot water d stribut on line and cold water line t traps shall consist of either a commercially llocated aslale heat tcl srap e as possible downward and upward benen to the storage tank. R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°4 ed R403.4.4A.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided tsupe mit the power supplied to the main burner(s) • to electric service systems to be turned off.A separate valve shall be provided to ermit the energy pp of combustion types of service water heating systems to be turned off. units shall t the minimum ies of Table .4.2 Water heating equipment. Water heating equipmentConservatled ion,IComlmercfiall Provisions,for the type of equipment installed. YV Table C404.2 in Chapter 4 of the Florida Building Code,Energy Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar eof nergy factor of the system.The solar energy factor hall be tested in aocordancel be rmined from the Florida Solar with SO Standard 9806,Test Methods forSolarCollectors, 1 Certified Solar Systems.Solar collector and SRCC Standard TMA,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria; 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. I8403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. !( to be operated at a positive indoor pressure or for mechanical R403.5.2 Ventilation air. Residential buildings designed ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. I 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or RA 9,space permitting,or R-10 otherwise. ,( R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. yJ l equipment uiment loads calculated in a cordance with ACCA Manual J or other approved heaHeatinand cooling equipment shall be sized in ting ndcool ng cal ulation methodologies, q pP based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor an indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. so that its R4016A.1 Cooling equipment capacity15 times only equip ment shall be selected calculated total load,but not more than e total load calculated according totthe procedure selected In al capacity is not less than the Section 403.6,or thebe osest less than available size a d stent the manufacturer's product lines.The corresponding latent capacity of the equipment shall not Page 2 of 3 1/7/2016 2:39 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com i FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This i selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. i Exceptions: I 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. I 2. When signed and sealed by a Florid a-registe red engineer,in attached single-and multi-family units,the capacity o equipment may be sized in accordance with good design practice. i I R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according Section l R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design • requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ' R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55'F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. 0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. p R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. p R403.9.3 Covers. Heated swimming pools and Ing round permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. such as a heat pump or i Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy, ' solar energy source computed over an operating season. RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed fighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R 6. R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. pa e 3 of 3 1/7/2016 2:39 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com g FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Builder Name: Toll Brothers Project Name: Cumberland 2125 Left W permit Office: Atlantic Beach Street: 1637 Atlantic Beach Dr.(Lot 7 AB) permit Number: I City,State,Zip: Atlantic Beach ,FL, Jurisdiction: 261300 Owner: Toll Brothers r Design Location: FL,Jacksonville I CHECK COMPONENT CRITERIA Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim 'oists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity s aces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have gasketed doors 1n12016 2:39 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 I I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Builder Name: Toll Brothers Project Name: Cumberland 2125 Left W permit Office: Atlantic Beach Street: 1637 Atlantic Beach Dr.(Lot 7 AB) Permit Number: City,State,Zip: Atlantic Beach , FL, Jurisdiction: 261300 Design Location: FL,Jacksonville Envelope Leakage Test Results Leakage Characteristics Regression Data: R:.... - -- - CFM(50): Single or Multi Point Test Data ELA: - - - --- --- ---- ------- -- ------ -- HOUSE PRESSURE I FLOW: EgLA: ACH: ACH(50): — SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through S.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; j 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,-shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Q � A I hereby certify that the above envelope leakage Where required by the code official, -- performance results demonstrate compliance testing shall be conducted by an i' �fl, � *�' approved third a A written i with Florida Energy Code requirements in PP party. r,,,,, ... c=• ,•;;,;� i repo of the results of the test shall �� ., accordance with Section R402.4.1.2. P be signed by the third party conducting the test and provided to u� I the code official. SIGNATURE: _ . COD NrE i PRINTED NAME: ---- - -- ------ BUILDING OFFICIAL: DATE: — DATE: ----- - ---- — ---r- ------- -- -. .I 117!2016 2:39 PM 9Y Ener Gauge®USA-FlaRes2014 -Section R405.4.1 Compliant Softwar Page 1 of 1 Lot 7 Manual S Compliance p liance Re ort Jab:Date: 1/7/16 117/16 CC TOV CC tieatlra rd Air By: Stephen Barber Endre House McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,FI 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Bacobs@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers FI Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 21497 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.2°F Latent gain: 4429 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 25926 Btuh Indoor RH: 50% Estimated airflow: 953 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0300000A+FB4CNP030L Actual airflow: 953 cfm Sensible capacity: 22400 Btuh 104%of load Latent capacity: 4429 Btuh 100%of load Total capacity: 26829 Btuh 103%of load SHR: 83% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 28499 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0300000A+FB4CNP030L Actual airflow: 953 cfm Output capacity: 28499 Btuh 100%of load Capacity balance: 33 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 953 cfm Output capacity: 9.0 kW 108%of load Temp. rise: 25 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Jan-07 11:35:30 " ft Comfort Builder by Wrightsoft 15.0.23 RSU12270 Page 1 wrlghtso i9lL�s^C1F\ ...nstruction\Toll Brothers\2.5 TON-Manual S.rup Calc=MJ8 House faces: W Job: Lot 7 ABCC Project Summary Date: 117116 Entire House By: Stephen Barber c «1�1Q McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,FI 32073 Phone:904278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers FI Notes: Cumberland Design Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 22746 Btuh Structure 15938 Btuh Ducts 3059 Btuh Ducts 3902 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25804 Btuh Use manufacturerdata n Rate/swing multiplier ier 1.04 Infiltration Equipment sensible load 20674 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 3145 Btuh Fireplaces 0 Structure Ducts 677 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ftp 2125 2125 Equipment latent load 4288 Btuh Volume(T) 21289 21289 24962 Btuh Air changes/hour 0.32 0.16 Equipment total load Equiv.AVF (cfm) 114 57 Req.total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade 14 SEER PURON HP Trade 14 SEER PURON HP Model CH14NBO300000A Cond CH14NBO300000A AHRI ref 0 Coil FB4CNP030L AHRI ref 0 Efficiency 8.2 HSPF Efficiency 11.7 EER, 14 SEER Heating Input Sensible cooling 20020 Btuh Heating output 28600 Btuh @ 47°F Latent cooling 8580 Btuh Temperature rise 27 °F Total cooling 28600 Btuh Actual air flow 953 cfm Actual air flow 953 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Jan-0711:21:02 "l w rightsoft' Comfort Builder by Wrightsoft 15.0.23 RSU12270 Page 1 ,CCA ...truction\Toll Brothers\Cumberland 2125 Left.rup Calc=MJ8 Front Door faces: W First Floor m,wic master bed 16 x 16 14x6 12„ 10x6 8 5" ® 4x8 8x4 6x12 3"Fan 4 m.bath 4 7" 12" family 12 x 12 Fa 3"Fan 8 24 x 18 14" 1 bath 2 6x10 6x12 bed 2, 6 7" 8 x 4 hall' 4„ 12x6 8x4 14" 12x12 5" 8" 10 x 10 kitchen' bed 3 6 x 10 9, 18" 6" 10 x 10 d OO o 16' 10x6 6" foyer garage 12 x 6 7^ d inq 10x6 6" Job#: Lot 7 ABCC McGowan's Heating & Air Conditioning, Scale: 1 : 101 Performed by Stephen Barber for: Page 1 Ton Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,FI 32073 15.0.23 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2016-Jan-0711:21:34 www.mcgowansac.com korey@mcgowansac.com rothers\Cumberland 2125 Left.rup Lot 7 Duct System Summary Job: 1/7/16 CC ��� Y Summary Date: 117116 !s••a'mg&�4+r`,� �64, Entire House By: Stephen Barber �Grl[ti-tSl7tfiltg McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,FI 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com 7*11:141 M • i I I n t • For: Toll Brothers FI Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.250/0.140 in H2O 0.250/0.140 in H2O Lowest friction rate 0.086 in/100ft 0.086 in/100ft Actual air flow 953 cfm 953 cfm Total effective length (TEL) 454 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (Cfm) (Cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk bath 2 c 129 3 6 0.110 4.0 Ox 0 VIFx 43.2 185.0 st2 bed 2 h 1809 67 60 0.108 6.0 Ox 0 VIFx 47.5 185.0 st2 bed 3 h 2191 81 76 0.145 6.0 Ox 0 VIFx 27.9 145.0 st1 dining h 2244 83 51 0.140 6.0 Ox 0 VIFx 33.5 145.0 SO dining-A h 2244 83 51 0.134 6.0 Ox 0 VIFx 41.4 145.0 st1 family C 2322 102 112 0.112 7.0 Ox 0 VIFx 39.2 185.0 st2 family-A C 2322 102 112 0.090 7.0 Ox 0 VIFx 52.3 225.0 st3 foyer C 2084 96 100 0.141 7.0 Ox 0 VIFx 32.6 145.0 st1 kitchen C 2561 77 123 0.108 7.0 Ox 0 VIFx 46.5 185.0 st2 laund. C 897 12 43 0.143 5.0 Ox 0 VIFx 29.6 145.0 st1 m.bath h 768 28 17 0.088 4.0 Ox 0 VIFx 59.4 225.0 st3 m.wic In 2388 88 44 0.086 5.0 Ox 0 VIFx 66.6 225.0 st3 master bed C 3244 130 156 0.089 8.0 Oxo VIFx 54.8 225.0 st3 wc C 37 1 2 0.089 4.0 Ox 0 VIFx 55.6 225.0 st3 SupplyDetail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 350 331 0.086 445 12.0 0 x 0 VinlFlx st2 st2 Peak AVF 599 632 0.086 591 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 953 953 0.086 683 16.0 0 x 0 VinlFlx 2016-Jan-07 11:21:02 wright'sofr Comfort Builder by Wrightsoft 15.0.23 RSU12270 Page 1 J'f4s .,.truction\Toll Brothers\Cumberland 2125 Left.rup Calc=MJ8 Front Door faces: W Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (Cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 170 242 147.2 0.095 226 14.0 Ox 0 VIFx rt1 rb4 Ox 0 248 220 162.5 0.086 316 12.0 Ox 0 VIFx rt1 rb3 Ox 0 274 289 143.0 0.098 828 8.0 Ox 0 VIFx rt1 rb2 Ox 0 261 203 134.5 0.104 749 8.0 Ox 0 VIFx rt1 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 953 953 0.086 539 18.0 0 x 0 VinlFlx 2015-Jan-07 11:21:02 I - wrightsoft' Comfort Builder by Wrightsoft 15.0.23 RSU12270 Page 2 AC4:k ...truction\Toll Brothers\Cumberland 2125 Left.rup Calc=MJ8 Front Door faces: W �t •, +FI CITY OF A,TLA I200 Sandpiper Lane ATLANTIC BEACFI,FL 32233 (904)270-2535 or(904)247-5874 NEW WATER/SEWER TAP REQUEST Date:_2- e-ol— /(e Project Address: /&32 No. of Units:�_Commercial Residential ✓ Multi-Family New Water T Meter(s) �(s)&M (s) Meter Size(s) /—t New Irrigation Meter Upgrade Existing Meter from to (size) • New Reclaimed Water Meter v"" 3 Size �q New Connection to City Sewer Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# /�o— —Zoo 9 Water System Development Charge $ ' 1 iffi,W Sewer System Development Charge $ ,�,pv Water Meter Only $ L 04T1W Reclaimed Meter Only $—Z6 , da Water Meter Tap $ Sewer Tap $ (notes) Cross Connection $ s!J—, Cgo Other $ TOTAL (o APPROVED: Kayle Moore,PE Xv1g (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAA REASSESSED 5_1' City of Atlantic Beach LBY: �� APPLICATION NUMBER Building Department C ' (To be assigned by the Building Department.) tla Seminole RoadAtlantic Beach, Florida 32233-5445FEa � 4 Zjj�FPhone(904)247-5826 • Fax(904) 450,119 E-mail: building-dept@coab.us Date routed: Z �4 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1lr3� ZC Ar%ServVices Department review required Yes No Applicant: �� Q s oning is ratorProject: AW /—I V/� � y Review fee $ d Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLATION STATUS Reviewing Department First Review: MApproved. [-]Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING 1 4j �� W11 -9 /IReviewed by: Da TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. JBEIC ORKS Comments: PUBLIC TILITIES 0 � PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 City of Atlantic Beach Building Department FFDate PLICATION NUMBER 800 Seminole Road ned by the Building Department.) Atlantic Beach, Florida 32233-5445 � �Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us d: Z City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1�3r- De artment review required Yes No Applicant: a nit &Zoning ` minis rator Project: NG f jV's JQ Public W c Utilitie Pu is Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: XApproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: TREE ADMIN. Second Review: DApproved as revised. []Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: DApproved as revised. []Denied. Comments: Reviewed by: Date: Revised 07/27/10 City of Atlantic Beach "A , Department FrDaterouted: PLICATION NUMBER 800 Seminole Road Z ed by the Building Department.) 9- — �r Atlantic Beach, Florida 32233-5445 -��� •��9 Phone(904)247-5826 • Fax(904)247-5845 r'JIT E-mail: building-dept@coab.us Z �� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 37Ck,,IjAr- De artment review required Ye No Applicant: l Q S a ning &Zoning t minis rator Project: W�v fjvr Public W C Utilitie Pu is Safety Fire Services ;Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt ed By Date Florida Dept. of Environmental Protection of Permit Verifi Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI TION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUI IN PLANNING &ZONING Reviewed by: Date �IL TREE ADMIN. Second Review: [Approved as revised. ❑Deni d PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 City of Atlantic Beach r Building Department ' - APPLICATION NUMBER 800 Seminole Road -'C�+ �'�j + o be assigned by the Building Department.) r Atlantic Beach, Florida 32233-5445FE Phone(904)247-5826 • Fax(904)247-5845 ?916 E-mail: building-dept@coab.us / City web-site: http://www.coab.us Date routed: APPLICATION REVIEW AND TRACKING FORM Property Address: �' — — --- —--- — Dh tCLf Ar' De artment review required Yes No Applicant: ��/ Hing&Zoning Project: �f,J minis rator - r�Y +q Public W c Utilitie Pu is Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified'B Date Florida Dept.of Environmental Protectio'_ n — ---- Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: _ APPLICATION STATUS Reviewing I Department First Review: []Approved. � L✓1Denied. (Circle one.) Comments: / � J BUILDING 41e 0"lL(>D� 4ZZ&At ,9G PLANNING &ZONING _ Reviewed by: ,� TREE ADMIN. V Date: f! �-d Second Review: []Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY _ Reviewed by: Date: FIRE SERVICES Third Review: QApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 Building Component Supply, Inc. B4627 J.P. Hall Blvd. Suite 208 CS Green Cove Springs, FL 32043 BUILDING COMPONENT SUPPLY,INC. Tel:• (904) 297-9390 Re : 8536TO Date: 01/15/16 Site Information: Project Customer: Toll Brothers Model Name :The Cumberland Lot/Block: 7 Subdivision :Atlantic Beach Elevation :Caribbean Name Address and License # of Structural Engineer of Record, If there is one, for this building. Name: Lou Pontigo&Assoc. - Lou Pontigo P.E. License#: 53311 Address: 420 Osceola Avenue , Jacksonville Beach, FL 32250 General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2014/TP12007 Design Program: 7.62 Apr 30 2015 Roof Load: 40.0 psf Floor Load: NIA Wind Code: MWFRS(Directional)/C-C hybrid Wind ASCE 7-10 Wind Speed: 130 mph This package includes 59 individual, dated rTruss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 611315-31.003, section 5 of the Florida Board of Professional Engineers Rules. No Date Truss ID# Seal# No Date Truss ID# Seal# No. Date Truss ID# Seal# 1 11/12/15 EJ02 A0088536 23 11/12/15 T06 A0088558 45 01/14/16 T37 A0088580 2 11/12/15 EJ03 A0088537 24 11/12/15 T07 A0088559 46 01/14/16 T38 A0088581 3 11/12/15 EJ04 A0088538 25 11/12/15 T08 A0088560 47 01/14/16 T39 A0088582 4 11/12/15 EJ05 A0088539 26 11/12/15 T09 A0088561 48 01/14/16 T40 A0088583 5 11/12/15 EJ06 A0088540 27 11/12/15 T10 A0088562 49 01/14/16 T41 A0088584 6 11112'15 EJ07 AG038541 28 11/i2ii5 T11 AG088563 50 131/14/10 T41A A0088585 7 11/12/15 EJ15 A0088542 29 01/14/16 T12 A0088564 51 01/14/16 T42 A0088586 8 11/12/15 EJ17 A0088543 30 01/14/16 T13 A0088565 52 01/14/16 T43 A0088587 9 11/12/15 EJ18 A0088544 31 01/14/16 T14 A0088566 53 01/14/16 T44 A0088588 10 11/12/15 EJ61 A0088545 32 01/14/16 T15 A0088567 54 01/14/16 T45 A0088589 11 11/12/15 HJ02 A0088546 33 01/14/16 T16 A0088568 55 01/14/16 T46 A0088590 12 11/12/15 HJ03 A0088547 34 01/14/16 T17 A0088569 56 01/14/16 T47 A0088591 13 11/12/15 J01 A0088548 35 01/14/16 T18 A0088570 57 01/14/16 T48 A0088592 14 01/14/16 PB01 A0088549 36 01/14/16 T19 A0088571 58 01/14/16 T49 A00885913 15 11/12/15 PB02 A0088550 37 01/14/16 T20 A0088572 59 01/14/16 T50 A0088594 16 11/12/15 P1303 A0088551 38 01/14/16 T21 A0088573 17 11/12/15 P604 A0088552 39 01/14/16 T22 A0088574 18 11/12/15 T01 A0088553 40 01/14/16 T26 A0088575 19 11/12/15 T02 A0088554 41 01/14/16 T27 A0088576 20 11/12/15 T03 A0088555 42 01/14/16 T28 A0088577 21 11/12/15 T04 A0088556 43 01/14/16 T29 A0088578 22 11/12/15 T05 A0088557 44 01/14/16 T30 A0088579 The truss drawing(s)referenced above have been prepared by MiTek Truss Design Engineer's Name:Julius Lee, PE Industries, Inc.under my direct supervision based on the parameters My license renewal date for the state of Florida is February 28,2017. provided by Building Component Suppy, Inc.in Green Cove Springs, FL. Note:The seal on these drawings indicate acceptance of Digitally signed by Julius professional engineering responsibility solely for the truss Lee components shown.The suitability and use of this component for an articular building Is the res onsiblit of the building �.us..S'K Y P 9 P Y 9 �J.. �cENSF .F�'; DN: c=US, st=Florida, desinger,per ANSI/TPI-1 Section 2. *. N 34869 1=Boynton Beach, o=Julius c� J, =� w,U= Lee, cn=Julius Lee, STATE OF '.FCORIOP'. (7\� email=leeengr@aol.com Date: 2016.01 .15 10:22:18 -05'00' Page 1 of 1 lob Tioul runs ype iOty -- Pty —-iihe Cumberiand 853610 ComerJadc 1 1 'k 1Job Reference motional)_____- — _ Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 UTek Industries,Inc. Fri Jan 15 0-8:12:57-20-1-6-Page-1 ID:x9nVlb8fQsyW522OBfFblzyMue3-?5MzU1 YKdrIF7RA6htcnipHb(OSF2g5361ZtL3zvB2a 1-1-1 --- -� 1-1-1- 7.0012 2 Scale=1:9.8 1 K. wi T1 29#/-18# 37#/0# B1 181/-4# 4 3 3x8 I I Plate Offsets(X,Y)- [4:0-4-4 0-1-5] — -- - ---- LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 I TC 0.03 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.02 Vert(TL) -0.00 4 >999 180 BCLL 0.0 ' Rep Stress Inc- YES WB 0.00 Horz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014fTP12007 (Matrix-M) Weight:4 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-1-1 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. �MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 4=37/0-5-8 (min.0-1-8),2=27/Mechanical,3=11/Mechanical Max Horz4=29(LC 12) Max Uplift2=-18(LC 12),3=-4(LC 12) Max Grav4=37(LC 1),2=29(LC 17),3=18(LC 3) FORCES. (lb)-Maximum Compression/Maximum Tension OFFICE VOPY TOP CHORD 14=29/5,11-2=-19/118 BOT CHORD 34=0/0 NOTES- 1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)zone;end vertical left exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 18 Ib uplift at joint 2 and 4 Ib uplift at joint 3. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard rnui I8iib T_ JE�J02 -Open :7y i The Cumbedand LL Job Reference(optiona) j Building Component Supply,Green Cove Springs,FL Run:7.620 sApr 30 2015 Print:7.620 s Apr 30 2015 Wek Industries,Inc. Fri Jan 15 08:12:58 2016 Page 1 ID:x9nVIb8fQsyW522OBfFblzyMue3-TlwLhNZyO8Q6lbklFa7OF1 p2Gno2nHLCLPIQtVzvB2Z 2-0-0 2-" Scale=1:12.4 2 7.00 12 T1 53#/-� 74#/-6# 1 _ 0-5-8(0-1-8) '4 B1 36#/-17# 4 3 3x8 11 Plate Offsets(X,Y)— [4:0-4-4,0-1-8] — LOADING(psf) SPACING- 2-0-0 CSL DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.06 Vert(LL) 0.00 4 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.05 Vert(TL) -0.00 3-4 >999 180 BOLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight:7 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer REACTIONS. (Ib/size) 4=74/0-5-8 (min.0-1-8),2=52/Mechanical,3=22/Mechanical Installation guide. Max Horz4=44(LC 12) Max Uplift4=-6(LC 12),2=-30(LC 12),3=-17(LC 12) Max Grav4=74(LC 1),2=53(LC 17),3=36(LC 3) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 14=-59/12,1-2=-34/29 BOT CHORD 34=0/0 NOTES- 1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)zone;end vertical left exposed;porch left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 6 Ib uplift at joint 4,30 Ib uplift at joint 2 and 17 Ib uplift at joint 3. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard I I I j 1 Job Truss rues ype �PIy - The Cumberland - 853670 P801 PIGGYBACK 1 1 f 1 _ Job Referenceo tionalL _ Beildinp Camponery SuR*Leen Cove Sprkw FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 MTek Industries,Inc. Fri Jan 15 08:13:01 2016 Pagel ID:x9nVlb8fQsyW522OBfFblzyMue3-tsbUJPbrh3ogc3TtwihjtfRZy?p7_evfl NX4UgzvB2W 2-10-14 --- 5-9-13— -- 2-10-14 2-10-15 4x5 Scale=1:11.0 3 1 7.00 F12 STI �TI 4 2 5 Q o Io I 6 2x4= 2x4 2x4= 5-9-13 5-9-13 LOADING(psf) T SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.03 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.02 Vert(TL) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.01 Horz(TL) 0.00 5 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix) Weight:13 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-9-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 FMiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. _1 REACTIONS. (Ib/size) 2=119/4-1-7 (min.0-1-8),4=119/4-1-7 (min.0-1-8),6=102/4-1-7 (min.0-1-8),1=-7/4-1-7 (min.0-1-8),5=-7/4-1-7 (min.0-1-8) Max Hoa 1=-24(LC 10) Max Uplift2=-31(LC 12),4=-31(LC 12),1=-16(LC 17),5=-7(LC 18) Max Grav2=121(LC 17),4=119(LC 1),6=102(LC 1),1=17(LC 11),5=9(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-28/41,2-3=-37/22,3.4=-36/22,4-5=-6/23 BOT CHORD 2-6=-11/18,4-6=-11/18 WEBS 3-6=-64/20 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.Il; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)zone;C-C for members and forces&MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Gable requires continuous bottom chord bearing. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 31 Ib uplift at joint 2,31 Ib uplift at joint 4,16 Ib uplift at joint 1 and 7 Ib uplift at joint 5. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 8)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable,or consult qualified building designer. LOAD CASE(S) Standard Job Truss russype Qty I PIy i Job Reference optional) 8536TO P1303 PIGGYBACK Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 KTek Industries,Inc. Fri Jan 15 08.13.01 2016 Page 1 ID:x9nVIb8fQsyW522OBfFblzyMue3-tsbUJPbrh3ogc3TtwihjtfRZW?pp_eof1 NX4UgzvB2W 2-10-14 _5-9_13 _ f 2-10-14 — 2-10-15 Scale=1:12.2 4x5= 3 7.00 12 1 ST1 4 2 5 1 o to 6 2x4-- 2x4 II 2x4 5-9.13 - - -- 5.9.13 -_ - -- LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.06 Vert(LL) 0.00 5 n/r 120 MT20 244/190 TCDL10.0 Lumber DOL 1.25 BC 0.04 Vert(TL) 0.00 5 n/r 120 BCLL 0.0 " Rep Stress Incr YES WB 0.02 Horz(TL) 0.00 4 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix) Weight:17 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-9-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3r MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer L Installation guide_ REACTIONS. (Ib/size) 2=122/4-1-7 (min.0-1-8),4=122/4-1-7 (min.0-1-8),6=150/4-1-7 (min.0-1-8) Max Horz2=-30(LC 10) Max Uplift2=41(LC 12),4=41(LC 12) FORCES. (Ib)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0/15,2-3=-51/30,3-4=-50/31,4-5=0/15 BOT CHORD 2-6=-6/22,4-6=-6/22 WEBS 3-6=-99/37 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)zone;C-C for members and forces&MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 41 Ib uplift at joint 2 and 41 Ib uplift at joint 4. 6)Non Standard bearing condition. Review required. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 8)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable,or consult qualified building designer. LOAD CASE(S) Standard - - o cuss i Truss Type--—— ry ---'Ffy-�umbedand 1 tI ' fI :853670 PB04 PIGGYBACK � -- ng po Supply,Green Cove S-n s,FL — -- _- Run.7. Job Reference o tiOnaU Buikli Com nent Su pfi g - - 620 s Apr 30 2015 Print 7.620 s Apr 30 2015 UTek Industries,Inc. Fri Jan 15 08:13:02 2016 Page 1 ID:x9nVIb8fQsyW522OBfFblzyMue3-L39sXkcTRNwXED24UQCyPt_iYP7lj5KoF1 GeOGzvB2V 1-4-14 2-10-14 4.4-15 5-9-13 1-4-14 - �- — 16.0 --- - -` — 1$1 1-4-14 Scale=1:11.5 4 3x6 - 3x6 7.00[12 3 T2 \ 5 T1 6 ugl 1 B1 v pCD o 0 n 2X4 2X4 =- 5-9-13 5-9-13 Plate Offsets(X,Y)- [10-3-0.0-1-12],[4:0-3-0,0-1-12]_ LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25TC 0.11 Vert(LL) 0.00 5 n/r 120 i MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.16 Vert(TL) 0.00 6 n/r 120 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 5 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix) Weight:15 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-9-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer REACTIONS. (Ib/size) 2=197/4-1-7 (min.0-1-8),5=197/4-1-7 (min.0-1-8) Installatio"uide,_ Max Horz 2=13(LC 11) Max Uplift2=-36(LC 12),5=-36(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0/15,2-3=-248/151,4-5=-248/152,5-6=0/15,3-4=-2161131 BOT CHORD 2-5=-104/216 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.ll; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)zone;C-C for members and forces&MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 36 Ib uplift at joint 2 and 36 Ib uplift at joint 5. 7)Non Standard bearing condition. Review required. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 9)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable,or consult qualified building designer. LOAD CASE(S) Standard ruSB O y The Cumberland 853670 EJ07 ___]J7-70p:: 10 1 Building Component Supply,Green Cove Springs,FL Run:7.620 s Job Reference(Optional Apr 30 2015 Print:7.620 s Apr 30 2015 MiTek Industries,Inc. Fri Jan 15 08:13:02 2016 Page 1 ID:x9nVlb8fOsyW522OBfFblzyMue3-L39sXkcTRNwXED24UQCyPt_bHP2Tj5KoF1 GeOGzvB2V 6.4-8 Scale=1:18.6 T 5.00 12 253#/-9# 1671W-59# i 7 N O v) N B1 117#/0# 3x5 11 3 Plate Offsets(X,Y— [1:0-24,0-1-11 _ 7_ LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) 0.09 3-6 >890 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.46 Vert(TL) -0.22 3-6 >342 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.03 1 n/a n/a BCDL 10.0 Code FBC2014(TP12007 (Matrix-M) I Weight:21 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE MiTek recommends that Stabilizers and required cross bracing Left:2x4 SP No.3 be installed during truss erection,in accordance with Stabilizer Installation guide. _ REACTIONS. (Ib/size) 2=167/Mechanical,3=86/Mechanical, 1=253/0-5-8 (min.0-1-8) Max Herz 1=76(LC 12) Max Uplift2=-59(LC 12),1=-9(LC 12) Max Grav2=167(LC 1),3=117(LC 3),1=253(LC 1) FORCES. (Ib)-Maximum Compression/Maximum Tension TOP CHORD 1-7=-99/16,7-8=-66/23,2-8=-63/51 BOT CHORD 1-3=-117/116 NOTES- 1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.ll; Exp B;Encl.,GCpi=0.18;MW FRS(directional)and C-C Exterior(2)0-0-0 to 3-0-0,Interior(1)3-0-0 to 6-3-12 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 59 Ib uplift at joint 2 and 9 Ib uplift at joint 1. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Tob toss —,Truss Ty—pe iQty 'Ply -TThe Cumberland --- -- --- -I' — f 1 8536TO T45 i Valley Job Reference fOnal _! Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 MiTek Industries,Inc. Fri Jan 15 08:13:04 2016 Page 1 ID:x9nVlb8fQsyW522OBfFblzyMue3-IRHcyQejz_AFTWCSbrEQV131 nCp4B_B5jLlk59zvB2T 4-0-0 � - 8-0-0 - ---- 4-0-0 a-ao 45= Scale:3/8"=1' 7.00 12 2 9 T7 ATl'� 10 2x4 11 2x4 11 7 V 1�� 3 "1 T I Ni ld N lLl B1 6 5 42X4 l 2x4 2x4 I I 8-0-0 8-0-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.19 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.14 Vert(TL) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.11 Horz(TL) 0.00 4 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix) Weight:40 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-M oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer _Installation guide. REACTIONS. (Ib/size) 6=152/8-0-0 (min.0-1-8),4=152/8-M (min.0-1-8),5=312/8-0-0 (min.0-1-8) Max Horz6=-45(LC 10) Max Uplift6=-39(LC 12),4=-39(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-6=-125/84,1-7=-77/53,7-8=-59/58,2-8=-47/69,2-9=-47/69,9-10=-59/58,3-10=-77/53,3-4=-125/84 BOT CHORD 5-6=-15/31,4-5=-15/31 WEBS 2-5=-224/62 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=24ft;eave=oft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-1-12 to 3-1-12,Interior(1)3-1-12 to 4-0-0,Exterior(2)4-0-0 to 7-0-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Gable requires continuous bottom chord bearing. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5).This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 39 Ib uplift at joint 6 and 39 Ib uplift at joint 4. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job I nlss fU88 ype —rQtyy. ..---TPIy_.TThe Cumberland 8536TO T13 Piggyback Base 2 1 Buildrg Component Supply.Green Cove Spings,FL Run:7.620 s i- ---Job Reference(optional) Apr 30 2015 Print:7.620 s Apr 30 2015 MiTek Industries,Inc. Fri Jan 15 08:13:15 2016 Page 1 I D:x9n VI b8fQsyW 522OBfFblzyMue3-TZS mFBmdONZh HCYa lex?RcOsmeOVGomj f YwgzOzvB21 5149 1159 17510 18$8 2110-0 28-57 340.7 39-11-0 5149 57-1 4314- - 57-1 -' 5-7-1 510.9 Scale=1:74.2 7.00 F12 5x6 2x4 11 5x6 6 7 8 3x6 5 Ag 4 2x4 4x5 3 511 25 26 4x5 ,2 12 10 W 12 20 27 19 28 18 -- 85 1Q 2- 45-0(0-1-8) 3x8 MT20HS= 0-5-8 2-6 1$) 58 20051!-210# 18 3x6= 7 # 2x4 1 3x8= 18-6-8 I 8-8-1 17.010 18-2-122_ 22-10-6 31-2-15 39.11-0 8-8-1 8+9 1-2-2t�-_...- 4314 --- - - &49 81 1 0.312 Plate-Offsets�,Y)- [1:0_5-2,0-1-14],[6:0-3-0,0-1-12],[8:0-114,0-2-4],[13:0-1-12,0-1 [18:0-2-12,0-3-0] LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) -0.35 18-20 >647 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.85I Vert(TL) -0.68 18-20 >328 180 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.75 Horz(TL) 0.02 13 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight:315 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 SP No.2"Except' end verticals. B3:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: WEBS 2x4 SP No.3 1 Row at midpt 7-18 OTHERS 2x4 SP No.3 WEBS Web Brace:Length(member)7-7-13(5-18);8-3-5(6-18);7-7-12 SLIDER Left 2x6 SP No.2 1-6-0 (9-16); T-Brace: 2x4 SP No.3-8-18 Fasten(2X) T and I braces to narrow edge of web with 1 Od(0.131"x3") nails,6in o.c.,with 3in minimum end distance. Brace must cover 90%of web length. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 1=558/0-5-8 (min.0-1-8),18=1949/0-5-8 (min.0-2-6),13=675/0-5-8 (min.0-1-8) - Max Horz 1=-199(LC 10) Max Upliftl=-65(LC 12),18=-21O(LC 12),13=-77(LC 12) Max Grav1=589(LC 21),18=2005(LC 17),13=733(LC 22) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-471/0,2-25=-718/146,3-25=-590/160,3-4=-542/145,4-5=-452/171,5-6=0/456,6-7=0/388,7-8=0/388,8-9=-199/190, 9-10=-546/196,10-11=-688/170,11-26=-124/91,12-26=-178/75,12-13=-203/104 BOT CHORD 1-20=-117/621,20-27=-65/245,19-27=-65/245,19-28=-65/245,18-28=-65/245,17-18=-21/36,7-18=-209/75,16-17=-219/0 ,16-29=-1/404,15-29=-1/404,15-30=-1/404,14-30=-1/404,13-14=-80/613 WEBS 3-20=-301/158,5-20=-32/579,5-18=-702/202,6-18=-381/57,16-18=-11/242,8-18=-1006/185,8-16=-128/694, 9-16=-617/198,9-14=-42/462,11-14=-220/157,11-13=-694/97 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 17-0-10,Exterior(2)17-0-10 to 22-10-6,Intedor(1)28-5-7 to 39-94 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)All plates are 3x4 MT20 unless otherwise indicated. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=I O.Opsf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 65 Ib uplift at joint 1,210 Ib uplift at joint 18 and 77 Ib uplift at joint 13. 9)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 10)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard 711,5u Russ ype Qty �fy Cum—[The beriandJob 8536TO Piggyback Base 1 1 Job Reference(optional) J Building Component Supply,Green Cove Springs,FL Run:7.620 s AAppr 30 2015 Print:7.620 s Apr 30 2015 M,Tek Industries,Inc. Fri Jan 15 06:13:16 2016 Pa 1 ID:x9nVl bBfQsyW 522O8fFblzyMue3-xl?9TXnF8g hYvM6m I MSE_gZwR2jQ?NtsUCEN W Szv82H 5109 11.5-9 1715 22-10-11 28-5-7 34-0-7 39-11-0 5 10 9 5.7-1 5$12 5-10-6 5$12 5-7-1 + 5-10-9 5x6= Scale=1:71.2 6x6= 7.00 12 6 7 14 3x4 3x6 3x4 5 8 3x6 4 9 W v 2x4 2x4 3 W3 t0 0 27 28 4x5%2 4x5 11 1 1 12-1 1O 00 5$( !, 18 29 30 17 16 31 15 14 32 33 13 161170-4-15) 3x4= 3x6— 3x4= 3x4= 0-4osAA bji_15) 1623#/-176# 3x8= 3x6= 8-8-1 17-0-5 22-1011 31-2-15 39-11-0 �— 8-8-1 8-4-4 5-10 6 844 8$1 PlateOffsetSTX,Yj_0:0-5-10,Edge],[6:0-3-0,0-1712],[7:0-1-8,0-2-4],[12 0-5-10 EdgeL_ — LOADING(psf) SPACING- 2-0-0 CSI. i DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0Plate Grip DOL 1.25 TC 0.85 Vert(LL) -0.30 13-15 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.93 Vert(TL) -0.67 13-15 >715 180 BCLL 0.0 Rep Stress Incr YES WB 0.25 Horz(TL) 0.18 12 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:246 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2'Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. T1:2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 5-16,7-16,8-15 WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing SLIDER Left 2x6 SP No.2 2-0-0,Right 2x6 SP No.2 2-0-0 be installed during truss erection,in accordance with Stabilizer Installation guide___ REACTIONS. (Ib/size) 1=1597/0-5-8 (min.0-1-15),12=1597/0-5-8 (min.0-1-15) Max Horz 1=200(LC 11) Max Upliftl=-1 76(LC 12),12=-176(LC 12) Max Grav 1=1617(LC 17),12=1623(LC 18) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-884/9,2-27=-2518/430,3-27=-2428/452,34=-2377/450,4-5=-2263/466,5-6=-1878/453,6-7=-1571/435, 7-8=-1889/453,8-9=-2272/466,9-10=-2387/450,10-28=-2437/452,11-28=-2528/430,11-12=-883/9 BOT CHORD 1-18=-311/2224,18-29=-237/1997,29-30=-237/1997,17-30=-237/1997,16-17=-237/1997,16-31=-1 13/1610, 15-31=-113/1610,14-15=-232/1865,14-32=-23211865,32-33=-232/1865,13-33=-232/1865,12-13=-306/2082 WEBS 3-18=-199/136,5-18=-20/373,5-16=-582/192,6-16=-86/648,7-16=-170/173,7-15=-84/719,8-15=-582/192,8-13=-20/373, 10-13=-199/136 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.Il; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 17-0-5,Exterior(2)17-0-5 to 22-10-11,Interior(1)28-5-7 to 39-11-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 176 Ib uplift at joint 1 and 176 Ib uplift at joint 12. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type y The Cumberland !—1 853670 T16 Hip 1 1 Job Reference(optional) Building Component Supply.Green Cove Springs,FL Run:7.620 a Apr 30 2015 Print 7.820 s Apr 30 2015 Walk kxk�ries,Inc.Fri Jan 15 08:13:17.2016 Page 1 ID:x9nVIb8K)syW5220BfFblzyMue3-PxDCgtolv�PXWhys3zTW163KS2ykm091sPw2uzvB2G 1 7-115 15.7-3 19-11 24 3 13 31-11-11 39-11-0 7-115 7-7-13 4 4 5 4-4-5 1 7-7-13 7-115 Scale=1:67.9 5x6= 7.00 Fi2 5x6= 5 26 6 27 7 3x6 3x6 4 828 25 �3 9 9 to � or 24 29 4x5%24x5 4x5 10 1 1 1� c 30 15 14 31 32 13 12 33 0*5$((� 2x4 11 5x12= 5x12- 2x4 11 77AJ! 77�## 1597#/-176# 1 7-11-5 15-7-3 24-3-13 31-11-11 39-11-0 7-115 7-7-13 8 8 10 7-7-13 --7-11-5 Plate Offsets(X,Y)- [1:0-5-t0,Edge],[3:0-1-12,0.1 8],[5:0.3-0,0.1-12],[7:0-3-0,0-1-12],[9:0.1-12,0.1-8],[11:0-5-10,Edge],113;0-5-12,0- ,114:0-5-12,0-3- LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.97 Vert(LL) -0.2813-14 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.98 Vert(TL) -0.54 13-14 >880 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.49 Horz(TL) 0.18 11 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:280 Ib FT=20% - - ------- ----'--------_ _ ___--------- - ----- - -- --------------- LUMBER- BRACING- TOP CHORD 2x4 SP No.1*Except* TOP CHORD Structural wood sheathing directly applied. T3:2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.2 WEBS Web Brace:Length(member)6-11-9(3-14);8-2-1 (6-14);8-2-1(6-13); WEBS 2x4 SP No.3 6-11-9(9-13); OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing l' SLIDER Left 2x6 SP No.2 2-0-0,Right 2x6 SP No.2 2-M be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 1=1597/0-5-8 (min.0-1-14),11=1597/0-5-8 (min.0-1-14) Max Horz 1=-183(LC 10) Max Upliftl=-176(LC 12),11=-176(LC 12) Max Grav 1=1 597(LC 17),11=1597(LC 18) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-949/0,2-24=-2459/430,3-24=-2303/450,3-25=-1967/410,4-25=-1897/418,4-5=-1846/445,5-26=-1623/440, 6-26=-1623/440,6-27=-1623/440,7-27=-1623/440,7-8=-1846/445,8-28=-1897/418,9-28=-1967/410,9-29=-2303/450, 10-29=-2459/430,10-11=-950/0 BOT CHORD 1-30=-303/2157,15-30=-303/2157,14-15=-303/2157,14-31=-167/1700,31-32=-167/1700,13-32=-167/1700, 12-13=-296/2034,12-33=-296/2034,11-33=-296/2034 WEBS 3-15=0/277,3-14=-581/184,5-14=-76/629,6-14=-274/85,6-13=-274/85,7-13=-76/629,9-13=-581/184,9-12=0/277 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 15-7-3,Exterior(2)15-7-3 to 29-11-9,Interior(1)29-11-9 to 39-11-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are 3x4 MT20 unless otherwise indicated. 5)This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 176 Ib uplift at joint 1 and 176 Ib uplift at joint 11. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job nlsS ruse Type 10-ty- ---(Ply–-The Cumberland II 8536TO T17 Hip 1 1 Job Reference(optional_ Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 MiTek Industries,Inc. Fri Jan 15 08:13:17 2016 Page 1 ID:x9nVIb%syW522OBfFblzyMue3-PxZXgtoty_pPXWhys3zTW 165AS7Rkoh?ispw2uzVB2G 7-2-12 14-2-1 19118 25-8-15 32-8-4 39.11-0 - 7-2-12 6-11 5 9 7 5-9 7 —+ 6-11-4 7-2-12 Scale=1:67.6 7.00 F12 5x8 2x4 11 5x8= 5 29 6 307 3x6 13 3x 6 4 8 28 3 93 W 13 o 45 21116 27 i 4 4x5 aa 10 1 - 1 O 1 Io 18 17 16 33 15 34 14 13 12 0 5 9 1�?, ) 2x4 11 3x6— 3x8= 3x6— 2x4 11 0--'Wi-14) 159 131 76# 1597#/-176# 7-2-12 14-2-1 19-11 6 25$-15 _32$-0 39-11-0 7-2-12 1 6-11-0 5-9-7 5 9 7 1 6-11-0 7-2-12 Plate Offsets.(X,)Jr 1:0-5-10,Edge],[3:0-1-12,0-1-8],[5:0-6-0,0-2-4],[7:0-",0-2-41,[9:0-1-12,0-1-8],J_1:0-5-10,Edge] LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/defl Ud T PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) -0.14 15-17 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.69 Vert(TL) -0.41 17-18 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.34 Horz(TL) 0.17 11 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight:268 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.1`Except` TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. T3:2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. BOT CHORD 2x4 SP No.1'Except* WEBS Web Brace:Length(member)6-1-10(3-17);6-5-14(6-15);6-1-10 B2:2x4 SP No.2 (9-13); WEBS 2x4 SP No.3 F MiTek recommends that Stabilizers and required cross bracing OTHERS 2x4 SP No.3 be installed during truss erection,in accordance with Stabilizer SLIDER Left 2x6 SP No.2 2-0-0,Right 2x6 SP No.2 2-0-0 Installation guide. REACTIONS. (Ib/size) 1=1597/0-5-8 (min.0-1-14),11=1597/0-5-8 (min.0-1-14) Max Horz 1=166(LC 11) Max Upliftl=-1 76(LC 12),11=-176(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-947/41,2-27=-2463/439,3-27=-2308/457,3-28=-2058/427,4-28=-1967/439,4-5=-1953/459,5-29=-1838/477, 6-29=-1838/477,6-30=-1838/477,7-30=-1838/477,7-8=-1953/459,8-31=-1967/439,9-31=-2058/427,9-32=-2308/457, 10-32=-2463/439,10-11=-947/41 BOT CHORD 1-18=-315/2097,17-18=-315/2097,16-17=-180/1740,16-33=-180/1740,15-33=-180/1740,15-34=-174/1689, 14-34=-174/1689,13-14=-174/1689,12-13=-309/2042,11-12=-309/2042 WEBS 3-18=0/235,3-17=-489/162,5-17=-27/464,5-15=-71/404,6-15=-377/158,7-15=-71/404,7-13=-27/464,9-13=489/162, 9-12=0/235 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.ll; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 14-2-1,Exterior(2)14-2-1 to 31-4-11,Interior(1)314-11 to 39-11-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are 3x4 MT20 unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 176 Ib uplift at joint 1 and 176 Ib uplift at joint 11. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard fuss Truss Type -Z�- P�-- The Cumberland —� 8536T0 T18 Hip 1 1 Job Reference(optional) Building Component Supply,Green Cove Springs,FLr3 Run:7.620 s Apr 30 2015 Print 7.620 s Apr 30 2015 MiTek Industries,Inc. Fri Jan 15 08:13:182016 Page 1 I D:x9n VI b8fQsyW 522OBfFblzyMue3-t87vuDoVg IxGSgG8QnU i3FeHArUTBx9xW8UaLvB2F 1 683 12-0 14 19-11-8 27-2-2 33-0-13 39-11-0 8S3 8-2-11 7-2-10 7-2-10 6-2-11 6-6-3 Scale=1:66.4 5x8= 2x4 11 5x8= 4 27 28 5 29 30 6 7.00 12 3x4 3x4 3 317 v N 25 4 32 ao cc 4x5%2 4x5 %V!l 8 1 9 1 [� C 16 15 1433 73 3412 11 10 c 2x4 3x4- 3x8 MT20HS= 3x8= 3x8 MT201-!S= 3x4= 2x4 11 176#) 1597#/-176# 683 _12-8-14 19-11-8 27-2-2 33.4-13 _ - 39-11-0 �- 683 6-2-11 7-2-10 7-2-10 _ 6-2-11 683 Plate Offsets(X,Y)— (1 0 3 8,Edge,,(3:0 1 12,0-1-8),[!CO-6-0,0-2-41,16:0_6-0,0-2-41,[7:0-1-12,0-1-8],[9:0-5-1 ge LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (]cc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) -0.17 11-13 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.70 Vert(TL) -0.4211-13 >999 180 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.60 Horz(TL) 0.16 9 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:233 Ib FT=20% LUMBER- — BRACING- TOP CHORD 2x4 SP No.1'Except' TOP CHORD Structural wood sheathing directly applied or 2-4-8 oc purlins. T2:2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. BOT CHORD 2x4 SP No.1'Except' MiTek recommends that Stabilizers and required cross bracing B2:2x4 SP No.2 be installed during truss erection,in accordance with Stabilizer WEBS 2x4 SP No.3Installation guide.__ SLIDER Left 2x6 SP No.2 2-0-0,Right 2x6 SP No.2 2-0-0 - REACTIONS. (Ib/size) 1=1597/0-5-8 (min.0-1-14),9=1597/0-5-8 (min.0-1-14) Max Horz 1=-149(LC 10) Max Upliftl=-176(LC 12),9=-176(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-958/70,2-25=-2460/447,3-25=-2325/461,3-26=-2141/436,4-26=-2122/467,4-27=-2053/504,27-28=-2053/504, 5-28=-2053/504,5-29=-2053/504,29-30=-2053/504,6-30=-2053/504,6-31=-2122/467,7-31=-2140/436,7-32=-2325/461, 8-32=-2460/447,8-9=-958/70 BOT CHORD 1-16=-325/2106,15-16=-325/2106,14-15=-208/1839,14-33=-208/1839,13-33=-208/1839,13-34=-202/1774, 12-34=-202/1774,11-12=-202/1774,10-11=-319/2041,9-10=-319/2041 WEBS 3-16=0/186,3-15=-399/142,4-15=-14/432,4-13=-92/533,5-13=490/203,6-13=-92/533,6-11=-14/432,7-11=-399/142, 7-10=0/186 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5f;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 12-8-14,Exterior(2)12-8-14 to 32-9-14,Interior(1)32-9-14 to 39-11-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 176 Ib uplift at joint 1 and 176 Ib uplift at joint 9. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard !Jo6 cuss uypeCumberiand _- 8536T0 T19 7L:]Hirp:- - — 1 ' Job Reference o tional) Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print 7.620 s Apr 30 2015 Wok Industries,Inc. Fri Jan 15 08:13:19 2016-Page 1 ID:x9nVIb8fOsyW522OBfFblzyQue3-LKhH5Zp8Rb37mgrL_UOxcSBOOFkeCfylAAu 17nzvi32E �._ 5-9-10 11-3-12 17-3-15 22-7-1 _28-7.4 34-1-6 _ 39-11-0 5 9 10 5$2 6-0.3 5-3-2 610-3 5-6-2 5-9-10 Scale=1:67.2 5x6= 34= 5x6= 4 28 29 5 30 6 7 31 32 8 33 7.00 F12 9 v 27 34 V 4x5 4x5 1 2 10 0 9( -- o 18 17 35 16 36 15 37 14 38 13 12 0-5-8j�-1-14) 2x4 11 3x8= 3x8 MT20HS= 3x8 MT20HS= 3x8= 2x4 11 1597#T11g6 1597#/-176# 5-9-10 11-3-12 19-11$ 28-7-4 1 34-1-6 i - --11-0 �— 5-9-10____—+ 5.6-2 1_ 8-7_-12 8-7-12 5$2 5-9-10 Plate Offsets(X,Y)— :0-3-8,Edc�e],_�3:0-1-12,0-1-81,L4:0-3-0,0-1-12],[8:0-3-0,0-1-121 j9:0--1-12,0-1-81,[11:0-5-10,Edge) _ — — - — — LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.99 Vert(LL) -0.23 13-15 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.96 Vert(TL) -0.57 13-15 >842 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.55 Horz(TL) 0.18 11 n/a n/a BCDL 10.0 Code FBC2014ffP12007 (Matrix-M) Weight:251 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.1'Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. B2:2x4 SP No.2 WEBS Web Brace:Length(member)6-10-14(5-17);6-10-14(6-13); WEBS 2x4 SP No.3 MiT k recommends that Stabilizers and required cross bracing OTHERS 2x4 SP No.3 I be installed during truss erection,in accordance with Stabilizer SLIDER Left 2x6 SP No.2 1-6-0,Right 2x6 SP No.2 1-6-0 1 Installation guide. REACTIONS. (Ib/size) 1=1597/0-5-8 (min.0-1-14),11=1597/0-5-8 (min.0-1-14) Max Horz 1=-133(LC 10) Max Upliftl=-1 76(LC 12),11=-176(LC 12) FORCES. (Ib)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-1188/130,2-27=-2454/441,3-27=-2352/465,3-4=-2220/473,4-28=-1871/449,28-29=-1871/449,29-30=-1871/449, 5-30=-1871/449,5-6=-2268/511,6-31=-1871/449,7-31=-1871/449,7-32=-1871/449,32-33=-1871/449,8-33=-1871/449, 8-9=-2220/473,9-34=-2352/465,10-34=-2454/441,10-11=-1188/130 BOT CHORD 1-18=-333/2086,17-18=-333/2086,17-35=-310/2264,16-35=-310/2264,16-36=-310/2264,15-36=-310/2264, 15-37=-316/2240,14-37=-316/2240,14-38=-316/2240,13-38=-316/2240,12-13=-327/2031,11-12=-327/2031 WEBS 3-18=-27/114,3-17=-303/122,4-17=-97/769,5-17=-652/135,5-15=0/223,6-15=0/223,6-13=-652/135,8-13=-97/769, 9-13=-303/122,9-12=-28/114 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 11-3-12,Exterior(2)11-3-12 to 34-1-6,Interior(1)34-1-6 to 39-11-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)All plates are 3x4 MT20 unless otherwise indicated. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)`This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 176 Ib uplift at joint 1 and 176 Ib uplift at joint 11. 9)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Tb —iTruss russT-a --- -- - - f5 - - YP - - tY Y The Cumberland 18536TO T20 1 Job Reference(optional) Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 WTek Industries,Inc.Fri Jan 15 08:13:21 2016 Paggee 1 I D:x9nV Ib8fQsyW522OBfFblzyMue3-ljp2 W E rOzDJr077j 5v2PhtGnG3TrgcObd UNBBgzv82C 7-0-0 9-10-1016-7-13 23-3-3 30-0-6 32-11-0 39-11-0 7-M --- 2-1 }0-10 6-9-3 6 7-7 —6-9 3-- 2-10-10 -- 7-0-0 Scale=1:67.1 5x8= 2x4 11 3x6= = 4 27 28 5x8 5 6 7 3031 32 8 7.00 12 2x4 2x4 3 9 33 v 4x5 i 2 4X5\ ty1 \ 10 �D 1 11BI 2 �1 o �o 17 34 1615 35 1413 36 12 0-5-8Jf�1 �) 3x6= 3x8= 0-018�j14) 159 3x6= 1597#/-176# s-10-10 16-7-13 z3-3-3 30-0-6 39-11-0 9-10-10 6-9 3 67 6-9-3 9-10-10 Plate Offsets(KY)- [1:0-3-8,Edge],[4:0-6-0,0-2-4],[8:0-6-0,0-2-4],[11.0-5-10,Edge] LOADING(psf) SPACING- 2-0-0 CSI. ; DEFL in (loc) I/deft Ud� PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 iVert(LL) -0.19 12-14 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.72 1 Vert(TL) -0.47 14-15 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.36 Horz(TL) 0.16 11 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) -- -- - - _ ----- - -- Weight:233 Ib FT=20% - - -- _- -- - __ - ---- - _� - LUMBER- BRACING- TOP CHORD 2x4 SP No.1'Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. T2,T3:2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 9-7-15 oc bracing. BOT CHORD 2x4 SP No.1'Except' WEBS Web Brace:Length(member)6-8-9(5-14); 132:2x4 SP No.2 MiTek recommends that Stabilizers and required cross bracing WEBS 2x4 SP No.3 be installed during truss erection,in accordance with Stabilizer OTHERS 2x4 SP No.3 Installation guide. SLIDER Left 2x6 SP No.2 2-0-0,Right 2x6 SP No.2 2-0-0 - ----—- - REACTIONS. (Ib/size) 1=1597/0-5-8 (min.0-1-14),11=1597/0-5-8 (min.0-1-14) Max Horz 1=-116(LC 10) Max Upliftl=-1 76(LC 12),11=-176(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-1090/0,2-26=-2429/459,3-26=-2321/487,34=-2253/494,4-27=-2515/566,27-28=-2515/566,28-29=-2515/566, 5-29=-2515/566,5-6=-2515/567,6-7=-2515/567,7-30=-2515/567,30-31=-2515/567,31-32=-2515/567,8-32=-2515/567, 8-9=-2253/495,9-33=-2321/489,10-33=-2429/461,10-11=-1090/0 BOT CHORD 1-17=-334/2057,17-34=-254/1969,16-34=-254/1969,15-16=-254/1969,15-35=-370/2530,14-35=-370/2530, 13-14=-254/1920,13-36=-254/1920,12-36=-254/1920,11-12=-326/2005 WEBS 3-17=-233/142,4-17=-33/359,4-15=-168/888,5-15=470/176,5-14=-85/69,7-14=422/183,8-14=-167/887,8-12=-32/360, 9-12=-233/141 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=S.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(l)3-11-14 to 9-10-10,Exterior(2)9-10-10 to 35-8-2,Interior(1)35-8-2 to 39-11-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are 3x4 MT20 unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 176 Ib uplift at joint 1 and 176 Ib uplift at joint 11. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard F '.853670 721 `Hi yp --. __--- --_ '1 ry y 1 The Cumberland I Job cuss Trust e - Q Pl- - — , r ► f ng Component soppy,Green Cave Springs,FL 1-D- - - Run:7. Apr 3--- Job Reference _phonal) Builth Can -- -- 620 s 0 2015 Print:7.620 s Apr 30 2015"Tek Industries,Inc Fn Jan 15 08:13:222016 Pagge 1 I D:x9n V I b8fQsyW522OBfFblzyMue3-mvNQjasO k WSidHawfdZeD5pxhSnyP2QIs86hj6zv82B 6-0.0 &S7 16-2-1— —--� -- 23-8-15 - - -- 31-5-9-. - 33-11-0 - -39-11-0 6-0.0 2 5 7 7-8-10 7-6-14 7-8-10 2-5-7 6-0.0 Scale=1:66.9 5x8= 3x6 Job hype y The Cumberland < is '.8536TO T22 Roof Special SWdural Gable 1 1 �Ob�� �(optional) Building C -- omponent Supply.Green Cove Springs,FL - Run:7.620 s Apr 30 2015 Print 7.820 s Apr 30 2015 MTek Nrduetriea,Inc. Fri Jen 1508:13:22 2016 Page 1 ID:x9nvlb8fOsyW522OBfFblzyMue3-mvNOjasOkWSidHawfdZeD5pxYSoHPzNls86hj6zvB2B _--__ 7-8-12_ $-5 3 1459 20-7-15M5 32-10 11 39-11-0 7-8-12 d5'7 6.1-6 - 6-1-6- - -1 6-1-6 6-1$ 74)-5 Scale=1:69.9 5x6= 7.00',125x6- 3x4= 3x4= 3x6= 3x4= 5x6= 3 27 5 26 6 7 8 29 4 30 31 9 32 0 4x5 %02 �; 33 4x5 ua "r 1 2 t0 a -- - o� oDOOM o. 17 1615 14 13 12 (0-2-5) 34 3R0-2-5) 3x6- 3x4= 3x4= 0l®1 8) 418%%40 178ftl05# 3x4= 3x6= 1223#/-154# 8-5-3 16-7-0 24-8-14 32-10-11 39-11-0 - 8-5-3 8-1-13 8-1-13 8-1-13 Plate Offsets�X,Y)- [1:0-3-0,0-1-1�,(9_0-3-0,0-1_12]_[11:0-5-10,Ed9e - - — - LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.87 i Vert(LL) -0.13 17-20 >800 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.78 Vert(TL) -0.38 17-20 >269 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.76 Horz(TL) 0.11 11 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight:203 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS T-Brace: 2x4 SP No.3-5-17 OTHERS 2x4 SP No.3 Fasten(2X) T and I braces to narrow edge of web with 1 Od(0.131"x3") SLIDER Left 2x6 SP No.2 1-6-0,Right 2x6 SP No.2 1-6-0 nails,6in o.c.,with 3in minimum end distance. Brace must cover 90%of web length. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide_. REACTIONS. (Ib/size) 1=230/15-5-8 (min.0-2-5),11=1223/0-5-8 (min.0-1-8),17=1741/15-5-8 (min.0-2-5),1=230/15-5-8 (min.0-2-5) Max Horz 1=90(LC 11) Max Upliftl=-94(LC 12),11=-154(LC 12),17=-105(LC 12) Max Gravl=418(LC 21),11=1223(LC 1),17=1786(LC 22),1=230(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-332/110,2-26=-340/382,3-26=-259/433,34=-139/491,4-27=-205/421,5-27=-205/421,5-28=-1465/418, 6-28=-1465/418,6-7=-2038/484,7-29=-2038/484,8-29=-2038/484,8-30=-1478/375,30-31=-1478/375,9-31=-1478/375, 9-32=-1694/385,32-33=-1711/369,10-33=-1801/365,10-11=-743/0 BOT CHORD 1-34=-330/225,34-35=-330/225,17-35=-330/225,16-17=-271/1183,15-16=-271/1183,14-15=-370/1908, 13-14=-370/1908,12-13=-369/2025,11-12=-235/1461 WEBS 3-17=-553/32,4-17=-4/113,5-17=-17521290,5-15=-25/746,6-15=-720/144,6-13=0/257,8-13=-12/160,8-12=-691/169, 9-12=-39/553 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.ll; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 7-8-12,Exterior(2)7-8-12 to 36-10-9,Interior(1)36-10-9 to 39-11-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 94 Ib uplift at joint 1,154 Ib uplift at joint 11, 105 Ib uplift at joint 17 and 94 Ib uplift at joint 1. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 8)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard Job Truss NSS ype �73fy i The Cumberiand i 853670 728 Roof Spaded 1 1 —Job Reference otip onal) Building Component Supply,Green Cove Springs,FL Run:7.620 sAqpprr 30 2015 Print 7.620 s Apr 30 2015 MiTek Industries,Inc. Fri Jan 15 08:13:23 2016 Page t ID:x9nVlb8fQsyW5220BfFblzyMue3-E5woxwseVgaZFR96DK4tmIL9ds7u8MTu5osFGYzvB2A 7 8 12 9 105 15-2-12 21-7-2 27-11-7 34-3-13 3311-0 7$12 2-1-9 5.4-7 6 4 6 6�6 645 -- 5-7-3 -- Scale=1:71.1 5x6= 7.00 12 3 5x6= 2x4 II 3x6= 4 5 9 5x6= 32 4x5 4x5 27 2 29 7 31 �. 33 Tti 2 %% \ 1 10%Vt R2 R1 " 1T 17 16 15 14 13 12 0-3-8(0-1-8) 1855#/22# 3x6 8139#/-112# 3x8= 7.8-12 _15.2-12 24-95 34313 3311-0 7$-12 I 7-6 0 i 95-9 95-9 5 7 3 Plate Offsets(X,Y)— [1:0-3-0,0-1-10],[9:0-3-0,0-1-12],[11:0-5-2,0-1-10) LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) 0.16 12-13 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.88 Vert(TL) -0.4512-13 >661 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.90 Horz(TL) 0.07 11 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:205 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 44-5 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3 6-0-0 oc bracing:16-17. OTHERS 2x4 SP No.3 WEBS Web Brace:Length(member)5-1-9(6-16); SLIDER Left 2x6 SP No.2 1-6-0,Right 2x6 SP No.2 1-6-0 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 1=449/0-3-8 (min.0-1-8),11=889/0-5-8 (min.0-1-8),16=1855/0-5-8 (min.0-2-3) Max Horz 1=90(LC 11) Max Upliftl=-223(LC 12),11=-112(LC 12),16=-322(LC 12) Max Grav1=483(LC 21),11=889(LC 1),16=1855(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-301/180,2-26=475/392,3-26=-380/412,34=-367/430,4-27=0/690,27-28=0/690,5-28=0/690,5-6=0/690, 6-29=-1152/282,7-29=-1152/282,7-30=-1152/282,8-30=-1152/282,8-31=-1034/273,9-31=-1034/273,9-32=-1177/276, 32-33=-1249/263,10-33=-1267/253,10-11=-522/21 BOT CHORD 1-17=-249/393,16-17=-270/261,15-16=-176/790,14-15=-176/790,13-14=-176/790,12-13=-258/1344,11-12=-160/1022 WEBS 3-17=-273/85,4-17=-5/266,4-16=-873/394,5-16=-393/153,6-16=-1603/271,6-13=0/596,8-13=-325/140,8-12=-362/116, 9-12=0/380 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 7-8-12,Extedor(2)7-8-12 to 38-3-12,Interior(1)38-3-12 to 39-11-0 zone;porch left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are 3x4 MT20 unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 223 Ib uplift at joint 1,112 Ib uplift at joint 11 and 322 Ib uplift at joint 16. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Typey me a,mbedana ! 853870 727 Roof Specal Girder CareJob Reference(optional) Wldirg + f BCarport Supply, en Cove Springs,FL —Run:7.620 s Apr 30 2015 Print 7.620 s Apr 30 2015 Welt Industries,Inc.Fri Jan 15 08:13:24 2016 Paye 1 ID:x9nVIb8fOsyW522OBffblzyMue341UABGtGG8iPtbklmlb6JWuGrGSetgW1JSboo? 29 40 2 7 812 1:1617 17.413 23-6-3 _ 29-7-9 35 815 39 11-0 40 2 3$10 8-1.6 6 1-0 6-1-6 6-1 6 42-1 Scale=1:69.9 5x6= 7.00 12 3 5x6—_ NAILEDNAILED NAILED 3x6 NAILED Special 4 I 4x1 — 4'_- x — = — NA ED NA ED 3xNA ED NA ED 3 —NAII ED NA ED 5x6 MIA 4x5 7 28 29 31 32 33 34 35 7 36 3 38 4x5 1 2 10 N nn nn d, 0 18 17 16 39 40 15 14 41 42 13 43 44 45 t2 46 0 01 ) 3x4— 0-5-8(0-�5Y NAILED 4x6= NAILED 3x4 cuss ruse Type -- y The Cumberland 853670 727 Roof Spedal Girder 1 t Job Reference(optional) Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 20151u . Industries,Inc. Fn Jan 15 08.13.24 2016 Page 2 ID:x9nVlb8fQsyW522OBfFbtzyMue3-ilUA8GtGG8iPtbklml b6JWuGrGSetgW 1 JSboo7zvB29 LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=-60,34=-60,4-9=-60,9-11=-60,19-23=-20 Concentrated Loads(lb) Vert:9=-107(F)16=-66(F)15=-66(F)8=-107(F)12=-66(F)14=-66(F)29=-107(F)30=-107(F)31=-107(F)32=-107(F)33=-107(F)35=-107(F)36=-107(F)37=-107(F) 38=-107(F)39=-66(F)40=-66(F)41=-66(F)42=-66(F)43=-66(F)44=-66(F)45=-66(F)46=-115(F) Juib �ss TrussType iQty 1 PIy 'The Cumbedand —' ` 853670 T,8 Valley i 1 1 Reference(optional) Bulking Component Supply,Grsen Cove Spring,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 WTek Industries,Inc. Fri Jan 15 08:13:04 2016 Pagel ID:x9nVIb8fQsyW5220BfFblzyMue3-IRHcyQejz_AFTWCSbrEQV13l gCp5B j5j Llk59zvB2T 4-0-0 8-0-0___ 4-0 0 4-0-0 -I 4x5— Scale=1:27.1 2 7.00 12 8 9 i 7 10 2x4 II 2x4 I 3 1 T I` i 1 N1 9 N B1 6 5 4 2.4 11 2x4 I I 2x4 11 _ 8-0-0 8-0-0 LOADING(psf) SPACING- 2-0-0 CSL DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.13 Vert(TL) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.07 Horz(TL) 0.00 4 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix) Weight:36 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-M oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 6=160/8-0-0 (min.0-1-8),4=160/8-" (min.0-1-8),5=297/8-0-0 (min.0-1-8) Max Horz6=-45(LC 10) Max Uplift6=41(LC 12),4=-41(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-6=-132/88,1-7=-90/59,7-8=-71/64,2-8=-59/74,2-9=-59/74,9-10=-71/64,3-10=-90/59,3-4=-132/88 BOT CHORD 5-6=-12/39,4-5=-12/39 WEBS 2-5=-210/55 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=24ft;eave=oft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-1-12 to 3-1-12,Interior(1)3-1-12 to 4-0-0,Exterior(2)4-0-0 to 7-0-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Gable requires continuous bottom chord bearing. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 41 Ib uplift at joint 6 and 41 Ib uplift at joint 4. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard 'Job Inm Truss Type -— y The Cumberland ,8536TO T47 Valley 1 1 Job Reference o tion! n9 Po �4pN.Green Cove _ �---- Building Component Sprv1ps,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 Welk Industries,Inc. Fri Jan 15 08:13:04 2016 Pa 1 ID:x9nVIb8fQsyW522OBfFblzyMue3-IRHcyQejz_AFTWCSbrEOV131 uCp3B?85jLIk59zvB2T 4-" 8-0-0 4-" 4-0-0 4x5= Scale=1:22.9 2 7.00 12 9 8 T1 T1 7 10 2x4 11 2x4 11 ST1 3 1 1 1 v N B1 6 5 4 2x4 11 2x4 11 2x4 1 8-0-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.14 Vert(TL) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.04 Horz(TL) 0.00 4 n/a n/a BCDL 10.0 Code FBC2014fTP12007 (Matrix) Weight:33 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 6=177/8-0-0 (min.0-1-8),4=177/8-0-0 (min.0-1-8),5=263/8-0-0 (min.0-1-8) Max Horz 6=45(LC 11) Max Uplift6=-45(LC 12),4=-45(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-6=-149/96,1-7=-121/73,7-8=-103/78,2-8=-91/88,2-9=-91/88,9-10=-103/78,3-10=-121/73,3-4=-149/96 BOT CHORD 5-6=-24/63,4-5=-24/63 WEBS 2-5=-175/39 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-1-12 to 3-1-12,Interior(1)3-1-12 to 4-0-0,Exterior(2)4-0-0 to 7-0-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Gable requires continuous bottom chord bearing. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 45 Ib uplift at joint 6 and 45 lb uplift at joint 4. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard cuss rues Type Y The a,mberiend 8536T0 Tao Courson Supported Gable 1 1 Job Reference(optional) Bum Component Supply,Green Cove Sprirps,FL Run:7.620 s Apr 30 2015 Print 7.620 s Apr 30 2015 Welt Industries,Inc.Fri Jan 15 08:13:07 2016��Pae9pee 1 ID:x9nVIb8fOsyW522OBWblzyMue3-iOzlaSgcGvZgK_wl Hzo76whaTOtiOLAXP4_OhUzvB2O 7$12 15-5-8 7-8-12 7-8-12 7 Scale=1:26.0 8 6 7.00 12 V 9 5 \� 10 4 � 3 TT T T 12 2 13 1 a a U LiB, 62 I 3x4 25 24 23 22 21 20 19 18 17 16 15 14 3x4- 3x6= 15-5-8 _ 15-5-8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.03 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.01 Vert(TL) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WS 0.03 Horz(TL) 0.00 13 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix) Weight:87 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installationuig de. REACTIONS. (Ib/size) 1=38/15-5-8 (min.0-1-8),13=38/15-5-8 (min.0-1-8),20=90/15-5-8 (min.0-1-8),21=110/15-5-8 (min.0-1-8),22=106/15-5-8 (min.0-1.8), 23=107/15-5-8 (min.0-1-8),24=107/15-5-8 (min.0-1-8),25=106/15-5-8 (min.0-1-8),19=110/15-5-8 (min.0-1-8),17=106/15-5-8 (min.0-1-8), 16=107/15-5-8 (min.0-1-8),15=107/15-5-8 (min.0-1-8),14=106/15-5-8 (min.0-1-8) Max Horz1=92(LC 11) Max Upliftl=-17(LC 10),21=-19(LC 12),22=-28(LC 12),23=-24(LC 12),24=-25(LC 12),25=-28(LC 12),19=-19(LC 12),17=-28(LC 12),16=-24(LC 12),15=-25(LC 12),14=-28(LC 12) Max Gravl=59(LC 18),13=43(LC 17),20=91(LC 17),21=112(LC 17),22=107(LC 21),23=107(LC 17),24=107(LC 17),25=110(LC 17),19=111(LC 22), 17=107(LC 18),16=107(LC 18),15=107(LC 18),14=108(LC 18) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-76174,2-3=-69/62,3-4=-63/52,4-5=-56/46,5-6=-76/81,6-7=-101/111,7-8=-101/111,8-9=-76/81,9-10=-47/46, 10-11=-36/18,11A2=113/26,12-13=-63/52 BOT CHORD 1-25=-46/61,24-25=-46/61,23-24=46/61,22-23=-46/61,21-22=46/61,20-21=46/61,19-20=46/61,18-19=46/61, 17-18=46/61,16-17=136/61,15-16=46/61,14-15=46/61,13-14=46/61 WEBS 7-20=-66/25,6-21=-85/46,5-22=-84/56,4-23=-81/52,3-24=-82/54,2-25=-82/55,8-19=-84/46,9-17=-84/56,10-16=-81/52, 11-15=-82/54,12-14=-82/55 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=24ft;eave=2ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Corner(3)0-0-0 to 3-0-0,Exterior(2)3-0-0 to 7-8-12,Corner(3)7-8-12 to 10-8-12 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 4)All plates are 2x4 MT20 unless otherwise indicated. 5)Gable requires continuous bottom chord bearing. 6)Gable studs spaced at 14-0 oc. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 17 Ib uplift at joint 1,19 Ib uplift at joint 21, 28 Ib uplift at joint 22,24 Ib uplift at joint 23,25 Ib uplift at joint 24,28 Ib uplift at joint 25,19 Ib uplift at joint 19,28 Ib uplift at joint 17,24 Ib uplift at joint 16,25 Ib uplift at joint 15 and 28 Ib uplift at joint 14. 10)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard JOD Truss Truss Type Qty Ply The Cumberland 953870 704 Cormion 1 1 Job Reference ' nal BuftV Car ponent Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print TOM u.Apr 30 Z�MTS bxWbies,kv.Fri Jen 15 09:13:07 2016 Page 1 ID:x9nVIb8K) 522 3 i0zla div K w1Hzo76wh000hfOEFXPJ_OhUzv820 I 7-0-0 9-11-0 14 0 8 185-8 7-0.0 2-11-0 4-1 8 1 45-0 4x5= Scale=1:38.4 4 \\/ 7.00F1_2 2x4 3 15 4x5 5 16 cc 14 Nr 2x4 11 05 1 6 2 B1 B2 r, 9 8 3x8 I 3x8= 3x6— 7 gg 0-5-8(0-1-0) (T 041.8) 732#V-80 9-11-0 18-5-8 ,,,e _ 9-11-0 8-6-8 Plate Offsets(X,Y)- [1:0-3-0,0-1-10] LOADING(psf) SPACING- 2-0-0 CSL DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) -0.14 9-12 >999 240 I MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.78 Vert(TL) -0.37 9-12 >588 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.47 Horz(TL) 0.04 1 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:97 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-64 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. SLIDER Left 2x6 SP No.2 1-6-0 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 1=732/0-5-8 (min.0-1-8),7=733/0-5-8 (min.0-1-8) Max Horz 1=-107(LC 10) Max Upliftl=-80(LC 12),7=-82(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-697/0,2-14=-916/162,3-14=-838/182,3-4=-722/189,4-15=-650/172,5-15=-724/153,5-16=-92/53,6-16=-134/41, 6-7=4 50/68 BOT CHORD 1-9=-1881724,8-9=-98/629,7-8=-98/629 WEBS 3-9=-312/154,4-9=-113/549,5-9=427/114,5-7=-760/144 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-0-0,Interior(1)3-0-0 to 9-11-0,Exterior(2)9-11-0 to 12-11-0 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 80 Ib uplift at joint 1 and 82 Ib uplift at joint 7. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Jo&-- -- Truss ------- - cuss e - - - - --. - — Y The Cumberland 8536TO T01 Hip Girder 1 1 Job Reference(optional) Buikfing Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print 7.620 s Apr 30 2015 Wek Industries,Inc. Fri Jan 15 08:13:08 2016 Page 1 4-270 9-11-0 ID:x9nVIb8fQsyW522OBfFblzyMue3-ADW7nohE1 Dhhy8VDggJMf8Ebjp?l7jLhezjyEwzvB2P - _ - 1 -5 9 0 - 4 2-0 4-2-0 540 - - Scale=1:32.8 5x6; NAILED Special Special NAED 1NAI ED 2>4 NAI ED 7.0 2 2 24 0 4x5 4x5 2 ��� 6 N H11- 7M 1 � � -- _ nn 26 11 27 2810 9 29 6 30 NAILED 2X4 II NAILED NAILED 3x8- 3x6- NAILED NAILED 4x10 1 2x4 II- 4x10 11 0-3-8(0-1$) NAILED NAILED NAILED NAILED 1 0-3-8(0-1-8) 140#/-548# 1141#/-549# 4 2-0 T 15-8-0 19-10-0 - 9-0 -- 5-9-0 _ 4-2-0 -- - - 5 Plate Offs --J1 ets(X,Y) :0-3-8,Edge],_[3:0-1 4,0-2 4�,[5:0-1 4 0 2 4],L-5-10,Edge] LOADING(psf) SPACING- 2-0-0 CSL DEFL in (loc) I/deft Ud j PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.15 8-10 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.84 Vert(TL) -0.24 8-10 >993 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.35 Horz(TL) 0.06 7 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:98 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-2-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-0-3 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing SLIDER Left 2x6 SP No.2 1 6-0,Right 2x6 SP No.2 1 6-0 be installed during truss erection,in accordance with Stabilizer REACTIONS. (Ib/size) 1=1140/0-3-8 (min.0-1-8),7=1141/0-3-8 (min.0-1-8) Installation uide. Max Horz 1=49(LC 6) Max Upliftl=-548(LC 8),7=-549(LC 8) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-850/448,2-3=-1631/802,3-20=-2139/1088,20-21=-2139/1088,21-22=-2139/1088,4-22=-2139/1088, 4-23=-2139/1088,23-24=-2139/1088,24-25=-2139/1088,5-25=-2139/1088,5-6=-1632/803,6-7=-850/448 BOT CHORD 1-26=-645/1344,11-26=-645/1344,11-27=-649/1349,27-28=-649/1349,10-28=-649/1349,9-10=-655/1350, 9-29=-655/1350,8-29=-655/1350,8-30=-652/1345,7-30=-652/1345 WEBS 3-11=-81/232,3-10=458/920,4-10=-585/284,5-10=457/919,5-8=-82/234 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional);porch left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 548 Ib uplift at joint 1 and 549 Ib uplift at joint 7. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 8)"NAILED"indicates 3-10d(0.148"x3")or 3-12d(0.148"x3.25")toe-nails.For more details refer to MiTek's ST-TOENAIL Detail. 9)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)89 Ib down and 88 Ib up at 4-2-0, and 89 Ib down and 88 Ib up at 15-8-0 on top chord. The design/selection of such connection device(s)is the responsibility of others. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=-00,3-5=-60,5-7=-60,12-16=-20 Concentrated Loads(lb) Vert:3=-49(B)5=-49(B)9=-29(B)11=-29(B)10=-29(B)4=-49(B)8=-29(6)20=-49(B)22=49(6)23=-49(6)25=-49(6)26=-73(B) 27=-29(B)28=-29(8)29=-29(B)30=-73(B) Job Hiss russ ype y The Cumberland 853670 702 Hip 1 1 Job Reference(optional) Building Component Supply,Green Cove Springs,R Run:7.620 s AApprr 30 2015 Print 7.620 s Apr 30 2015 FATek Industries,Inc. Fri Jan 15 08:13:08 2016wzv9Paee 1 _ ID:x9nVIb8fOsyW5220BfFblzyMue3-ADW7nohElDhhy8VDggJMfBEYKp6X7kphezjyE2P 63-2-0 7-0 0 --- 18-2-12 19-10-0 4-6-12 Scale=1:33.7 4x5= 4x10= 3 22 23 24 25 4 7.00 F12 T2 21 26 4x5 20 T 275 4\4x5 2 6 1 1 � 7 B1 EE1 Io 11 10 9 3x8 11 3x4= 3x6— 3x4= 8 3x8 11 0-3-8(0-1-8) 2x4 11 0-5-8(0-1-8) 724#/-262# 863#/-277# 6-2-0 13-8-0 18-2-12 19-10-0 5-2-0 7-6-0 4-6-12 Plate Offsets(X,Y)– [1:0-M.0-1-101,[4:0-7-8,0-2-0] [5.0-1-12 0-1-8] [7:0-5-2,0-1-141 LOADING(psf) SPACING- 2-0-0 CSI. —T DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) 0.11 9-11 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.42 Vert(TL) -0.17 9-11 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.26 Horz(TL) 0.02 8 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:101 Ib FT=20% LUMBER- - BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-M oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing SLIDER Left 2x6 SP No.2 1 6-0,Right 2x6 SP No.2 1 6-0 be installed during truss erection,in accordance with Stabilizer REACTIONS. (Ib/size) 1=724/0-3-8 (min.0-1-8),8=863/0-5-8 (min.0-1-8) Installation nuide. Max Horz 1=-72(LC 10) Max Upliftl=-262(LC 12),8=-277(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=438/390,2-20=-963/713,20-21=-902/723,3-21=-887/739,3-22=-767/685,22-23=-767/685,23-24=-767/685, 24-25=-767/685,4-25=-767/685,4-26=-084/627,26-27=-799/611,5-27=-809/604,5-6=0/54,6-7=43/68 BOT CHORD 1-11=-558/765,10-11=458/642,9-10=458/642,8-9=-19/13,7-8=-19/13 WEBS 3-11=-203/216,4-11=-124/191,4-9=-115/109,5-9=481/673,5-8=-787/542 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf,h=25ft;B=45ft;L=24ft;eave=oft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-M to 3-M,Interior(1)3-0-0 to 6-2-0,Exterior(2)6-2-0 to 17-10-15, Interior(1)17-10-15 to 19-10-0 zone;cantilever right exposed;porch left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 262 Ib uplift at joint 1 and 277 Ib uplift at joint 8. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard runs russ vpe Y=Cumbrerdn:4703 Hip 1 Builth Can nen.S (optional ng po apply,Green CoveSprings,FL Run:7.820 s r 30 2015 Print 7.620 s Apr 30 2015 PA l ek Industries,Inc. Fd Jan 15 08:13:09 2016P 1 ID:x9nVlb8(QsyW522OBfFblzyMue3-eP4V?8 hsoXpYZH4OOOq bCLmpCDRxsCFgtcTVmMzve2O 6-2-0 8-2-0 11-8-0 18-2-12 19-10-0-- 62-0 200 360 612 - - 14 4x5= Scale=1:37.6 4x5 4 5 T2 \\ 7.00 12 2x4 3 i 22 23 a 21 24 3x4 4x5 1 6 4x5 Ln 2 7 1 1 8 61 FTJto 12 „ 3 10 9 3x8 11 x8 I I 3x8= _ 0.5.8(0-1-) 365 81-) 0-2x4 11 -) "72# 525 91# 501#/-135# 8-2-0 124114 _ 18.2-12 1910-0 8-2-0 4$4 5 6 8 1-7� _Plate Offsets(X,Y)— [1:0-3 0 0-1-141 r5:0-2-8,0-141,[6:0-1-12 0-1-8],[8:0-5 2,0-1-14] LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Vert(LL) -0.08 12-15 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.47 Vert(TL) -0.22 12-15 >673 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.24 Horz(TL) 0.03 1 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight:110 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing SLIDER Left 2x6 SP No.2 1 6-0,Right 2x6 SP No.2 1 6-0 be installed during truss erection,in accordance with Stabilizer REACTIONS. (Ib/size) 1=560/0-5- (min.0-1-8),10=525/0-5$ (min.0-1-8),9=501!0-5-8 (min.0-1-8) Installation guide. Max Horz 1=-96(LC 10) Max Upliftl=-72(LC 12),10=-91(LC 8),9=-135(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-563/0,2-21=-645/164,21-22=-582/165,3-22=-558/180,3-0=-515/193,4-5=421/168,5-23=-250/147,23-24=-264/125 ,6-24=-287/117,6-7=-67/148,7-8=-118/138 BOT CHORD 1-12=-132/526,11-12=-25/239,10-11=-25/239,9-10=-130/113,8-9=-130/113 WEBS 3-12=-294/151,4-12=-66/242,5-12=0/305,5-10=-458/69,6-10=-12/150,6-9=461/129 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-M to 3-M,Interior(1)3-M to 8-2-0,Exterior(2)8-2-0 to 11-8-0, Interior(1)15-10-15 to 19-10-0 zone;end vertical right exposed;porch right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3--0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 72 Ib uplift at joint 1,91 Ib uplift at joint 10 and 135 lb uplift at joint 9. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard "Joy rues i Trus ype - y The Cumberland !,853670 T05 Roof Special Girder 1 1 Building Component Supply,Green Cove S Job Reference(optiona0 pn •FL Run.7.820 sAp r 30 2015 MnL 7.620 s Apprr 30 2015 2.111 Industries,Inc. Fri Jan 15 08:13:10 2016 Page 1 ID:x9nVIb8fQsyW5220BfFblzyMue3-6betCUiUZgxPBRfcy5LgkZ)tSdiybYbz5GC310z, 2N 51� 911-0 17-15 24911 30-11-2 37-2-5 39-11-0 5 1� 49 12 7-2-5 5x6= Scale=1:72.0 7.00 12 4 2x4 4x6= NAILEDNAILED NAILEDNAILED NAILED 3 5x6= NAI D 1 2x4 11 3x6—3x4— Sx8= 4x5 5 6 NA ED 7 NA D 9 NA DNA ED 10 35 4x5 1 2 _ W4 5 26 27 28 29 32 33RP 11 = a 1�20 19 16 isl� � _ 1 675#0-5-810-1g-8) 7$0 12#) 3x8= 3x6= 0-5-8(pr`4)=NAILED 16 NAILED 14 NAILEDNAILED13 0- 2-0) 2698#/-303# 3x8 MT20HS= 1687 - 12# 3x4 4x10 3x5= 3x5= 2x4 II NAILED NAILEDNAILED NAILEDNAILED NAILED 9.11-0 18-2-12 1 249-11 _ 30.11-2 37-2-5 39 71-0 911-0 8312 12 63-0 61-7 633 2811 Plate Offsets(X Y)— [1:0-2-0.0-0-2] [6 0 2-12 0-1-81 110:045-0.0-2-41,[13:0-2-4,0-1-81,[14:0-2-0,0.1-81 [16.0-4-0 0 1 12] [18 0 3-0,0-2-1121 LOADING(psf) SPACING- 2-0-0 CSI. T EFL. in (loc) I/def! L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94ert(LL) -0.12 14-16 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 1BC 0.81ert(TL) -0.32 14-16 >803 180 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr NO WB 0.69orz(TL) 0.02 1 n/a n/a BCDL 10.0 Code FBC2014ITP12007 (Matrix-M) Weight:211 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2*Except* TOP CHORD Structural wood sheathing directly applied or 2-11-1 oc purlins, except T4:2x4 SP SS end verticals. BOT CHORD 2x4 SP No.1'Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: B2:2x4 SP No.2 6-0-0 oc bracing:18-20,16-17. WEBS 2x4 SP x SP *Except* MiTek recommends that Stabilizers and W5:2x4 SP Not be installed during truss erection,in accordance rdlwitred h Stabilizer SLIDER Left 2x6 SP No.2 1-6-0 Installation guide. REACTIONS. (Ib/size) 1=675/0-5-8 (min.0-1-8),18=2698/0-5-8 (min.0-3-3),12=1685/0-5-8 (min.0-2-0) Max Horz 1=155(LC 7) Max Upliftl=-1 02(LC 25),18=-303(LC 8),12=-212(LC 8) Max Grav 1=675(LC 1),18=2698(LC 1),12=1687(LC 18) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-727/0,2-3=-866/191,34=-633/168,4-5=-670/155,5-6=-89/507,6-25=-2433/294,25-26=-2433/294,26-27=-2433/294 7-27=-2433/294,7-28=-2433/294,28-29=-2433/294,29-30=-2433/294,8-30=-2433/294,8-31=-2433/294, 9-31=-2433/294,9-32=-3039/380,32-33=-3039/380,33-34=-3039/380,10-34=-3039/380,10-35=-1579/209, 11-35=-1634/203,11-12=-1647/188 BOT CHORD 1-20=-122/768,19-20=-200/273,18-19=-200/273,17-18=0/212,6-18=4819/312,17-36=-292/76,36-37=-292/76, 37-38=-292/76,16-38=-292/76,16-39=-341/3039,15-39=-341/3039,1540=-341/3039,14.40=-341/3039, 14-41=160/1380,41-42=-160/1380,4243=-160/1380,13-43=-160/1380,1344=21119,1244=-21/19 WEBS 3-20=-298/117,4-20=-29/354,5-20=-55/520,5-18=-823/224,6-16=-325/3040,7-16=-700/245,9-16=-686/108, 9-14=492/231,10-14=-204/1851,10-13=-404/136,11-13=-172/1601 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional);end vertical right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 102 Ib uplift at joint 1,303 Ib uplift at joint 18 and 212 Ib uplift at joint 12. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 9)"NAILED"indicates 3-1Od(0.148"x3")or 3-12d(0.148"x3.25")toe-nails.For more details refer to MiTek's ST-TOENAIL Detail. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard Continued on page 2 o Truss russType --- ----iO�yTPIy TheCumbedand ;_ _�_ Job Reference(optional) ' 853670 705 Roof Speaal Girder Run.7.6620 s r 30 2015 Print 7.620 s Apr 30 2015 MiTek Industries,Inc. Fn Jan 15 08:13:10 2016 Pa 2 Bwkling Component Supply,Green Cove Springs,FL AApp pp ggee x9nVlb8fQsyW522OBfFblzyMue3 6betCUiUZgxPBRfcy5LgkZJtSdiybYbz5GC31ozv82N LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:14=-60,4-5=-60,5-10=-60,10-11=-60,18-21=-20,12-17=-20 Concentrated Loads(lb) Vert:15=-70(B)25=-117(B)26=-117(B)27=-117(B)28=-117(B)30=-117(B)31=-117(B)32=-117(B)33=-117(B)34=-117(B)35=32(B)36=-70(B)37=-70(B)38=-70(B) 39=-70(B)40=-70(B)41=-70(B)42=-70(B)43=-70(B)44=-219(8) JW russruS3 __ YPe �ty -"Ply The Cumberland 8536TO T06 Roof Special 1 1 Buiklin Component Su --- - _- mob Reference o tionalL__ 9 Po PPh,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 MTek Industries,Inc. Fri Jan 15 08:13:10 2016 Pagge 1 I D:x9n VI b8fQsyW 522OBfFblzyMue3-6betCU i UZgxPBRfcy5Lq kZJ_3d hu bZBz5GC31ozvB2 N 5-1.4 9-11-0 15-8-3 � -1 24-3-6 ---30 0 5 5-35 14 39-11-0 5-1-0 4-9-12 5-95 ' - 8-7--7- 3 5-8-148-14 Scale=1:71.1 54= 7.00 12 4 2x4 25 26 5x6= 2x4 II 3x6= 3 5 6 4x5 == 3x4= 5x6- N 4x5 24 T3 7 - �4-- 10 - - c� 7 828 �� 29 4x5 1 2 T5 IM 11 w 1 Gto y3; A.,O ,R 19 18 17 — a�) 3x8= 3x8— 0-5 8(p=2-0) 3x4= t3 0- 1-8) 167 177# 3x6= 809 - 3# 4x5= 3x8= 2x4 ;1 _9-11-0 18-2-12 181-¢-8 27-1-13 35-9-33911-0 9-11-0 8-312 0$12 8-75 8-7-5 _ 4-1-13 Plate Offsets("-- [1.0-2-0,0-0-2 110:0-3-0 0-1-12j, 17:0-3�,0-2 4) LOADING(psf) SPACING- 2-0-0 CSL DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 1 Vert(LL) -0.12 19-22 >999 240 MT20 244/190 TCDL 10.0Lumber DOL 1.25 BC 0.88 Vert(TL) -0.3215-16 >800 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.58 Horz(TL) 0.02 17 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight:218 Ib FT=20% LUMBER- - BRACING-- -- — TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-7-9 oc purlins, except BOT CHORD 2x4 SP No.2"Except' end verticals. B3:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SPFMiTek recommends that Stabilizers and required cross bracing SP No.2 No.2 W5:2x6 SP be installed during truss erection,in accordance with Stabilizer SLIDER Left 2x6 SP No.2 1 6-0 Installation guide. REACTIONS. (Ib/size) 1=704/0-5-8 (min.0-1-8),17=1672/0-5-8 (min.0-2-0),12=805/0-5-8 (min.0-1-8) Max Horz1=155(LC 11) Max Upliftl=-82(LC 12),17=-177(LC 12),12=-93(LC 12) Max Grav 1=704(LC 1),17=1672(LC 1),12=809(LC 22) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-750/0,2-24=-920/197,3-24=-813/216,3-25=-684/159,4-25=-623/182,4-26=-612/164,5-26=-692/144,5-6=-28/213, 6-7=-17/158,7-27=-992/229,27-28=-992/229,8-28=-992/229,8-9=-992/229,9-29=-711/190,10-29=-711/190, 10-11=-876/181,11-12=-784/169 BOT CHORD 1-19=-148/757,18-19=-57/415,17-18=-57/415,16-17=-95/713,6-17=-266/97,15-16=-133/770,14-15=-205/1074, 13-14=-205/1074,12-13=-30/48 WEBS 3-19=-295/145,4-19=-34/403,5-19=-3/163,5-17=-878/192,7-16=-1115/230,7-15=4/423,9-15=-145/118,9-13=444/115, 10-13=0/231,11-13=-101/722 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 9-11-0,Exterior(2)9-11-0 to 13-10-14,Interior(1)15-8-3 to 35-9-3 zone;end vertical right exposed;C-C for members and forces&MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 82 Ib uplift at joint 1,177 Ib uplift at joint 17 and 93 Ib uplift at joint 12. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard 0 r s�T-s russ ype �QTy y The Cumberland • 8536TI T07 Roof Special 1 1 --- -1 Job Reference(optional) Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print 7.620 s Apr 30 2015 Hlrek Industries,Inc. Fri Jan 15-0811112016 Paggee 1 ID:x9nVlb8fQsyW522OBfFblzyMue3-aoCGQpj6K83FpbEoWps3Hms5t13gK1 s7KwycgFzv82M 1- 5-149-11-0 1431 1 18 6 8 F 26-5-4 34-4-1 39-11-0 5-14 4-9-12 4-4-1 437 7-10-12 -- - 7-10-12 - -- -5-6-15 -- Scale=1:71.1 5x6= 7.00 12 4 25 2x4 54- 4x5= 3x6= 2x4 II 5x8= 3 24 5 6 B 9 Pi CC 4x5 23 7 27 28 29 30 4x5 1 2 X31 10 B11 R \ o o 18 77 16 701440-1-8) 3x8= 3x6- 0-5.802-0) 14 12 0- 1-8) 1678#/170# 807#1- 3x4 I 3x8= 34- 3x4= 2x4 9-11-0 18-2-12 18r¢-_826-54 34-4-1 _ 39-11-0 9-11-0 8_3-12 0-3'12 7-10-12 _ 7-10-12 5-6-15 Plate Offsets X,Y)- [1:0_2_0,0-0-2]'[9-0-",0-2-41,[114:0-2-8,0-_1 8],[14 -2-41 --- --- -- - LOADING(psf) SPACING- 2-0-0CSI. I DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25TC 0.71 i Vert(LL) -0.1218-21 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.77 Vert(TL) -0.31 18-21 >720 180 I BCLL 0.0 ' Rep Stress Incr YES WB 0.56 Horz(TL) 0.02 16 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight:217 Ib FT=20% LUMBER- - — — BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins, except BOT CHORD 2x4 SP No.2'Except' end verticals. B3:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3 6-0-0 oc bracing:14-15. SLIDER Left 2x6 SP No.2 1-6-0 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer REACTIONS. (Ib/size) 1=701/0-5-8 (min.0-1-8),16=1678/0-5-8 (min.0-2-0),11=802/0-5-8 (min.0-1-8) Inst_alla_tion guide. Max Horz 1=155(LC 11) Max Upliftl=-85(LC 12),16=-170(LC 12),11=-96(LC 12) Max Grav 1=701(LC 1),16=1678(LC 1),11=807(LC 22) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-749/0,2-23=-916/206,3-23=-810/226,3-24=-676/167,4-24=-615/190,4-25=-644/182,5-25=-657/161,5-26=-10/160, 6-26=-10/160,6-7=-863/256,7-27=-863/256,8-27=-863/256,8-28=-863/256,28-29=-863/256,9-29=-863/256, 9-30=-791/199,30-31=-835/185,10-31=-912/179,10-11=-760/177 BOT CHORD 1-18=-149/756,17-18=-64/485,16-17=-64/485,15-16=0/135,6-16=-986/257,14-15=-122/47,13-14=-116/719, 12-13=-116/719,11-12=-40/84 WEBS 3-18=-298/148,4-18=-68/414,5-18=-40/132,5-16=-843/162,6-14=-209/1141,8-14=-510/205,9-14=-47/168,9-12=-48/135 ,10-12=-82/682 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 9-11-0,Exterior(2)9-11-0 to 13-10-14,Interior(1)14-3-1 to 39-9-4 zone;end vertical right exposed;C-C for members and forces&MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 85 Ib uplift at joint 1,170 Ib uplift at joint 16 and 96 Ib uplift at joint 11. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard hiss russ YPe P Y The Cumberland fi 853670 TOB Roof Special 1 1 Ouikiing Component Supply,Green Cove Springs,FL Job Reference o tional Run:7.620 s Apr 30 2015 Print 7.620 s Apr 30 2015 ABTek Industries,Inc. Fri Jan 15 08:13:112016 Pa �e 1 ID:x9nVlbBfQsyW5220BfFblzyMue3-aoCGQpj6K83FpbEoWps3Hms8812vKxL7KwycgFzvB2M 51� 911-0 12-914 18 22$11 26-10-14_ 29-10-14 34-9-3 39-11-0 5 1� 4 9 12 2-10 14 5$10 4-2-0 4-2-3 —� 3-0 0 4 10 5 5 1-13 Scale=1:71.1 54= 5x6= 7.00 12 4 9 5x8= 4x5= 2x4 II 5x6 5 8 7 \25 28 4x5 3 26 27 10 24 2 29 4x5 IM 2X4 11 N 1 2 L - R1 1 11 0 .131 0 19 18 17 2 6 0-1-8) 3x8= 3x6= 0-5;p2-0) 15 13 04# 169 153# 2x4 I 3x8= 3x6_— 3x8= 3x5= 9-11-0 18-2-12 11"-8 '-1 22$11 29-10-14 39.11-0 9-11-0 8-3-12 12 4-2-3 7-2-3 10-0-2 Plate Offsets(X,Y)~ [1:0-2-0,0-0-2],[12:0-2-4,0-1-8,[117:0-3-4,0-241 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) -0.2412-13 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.83 Vert(TL) -0.6012-13 >423 180 BCLL 0.0 " Rep Stress Incr YES WB 0.91 Horz(TL) 0.02 17 n/a We BCDL 10.0 Code FBC2014ITP12007 (Matrix-M) Weight:240 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 SP No.2*Except* end verticals. B3:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3 6-0-0 oc bracing:15-16. SLIDER Left 2x6 SP No.2 1-6-0 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer i REACTIONS. (Ib/size) 1=694/0-5-8 (min.0-1-8),17=1692/0-5-8 (min.0-2-0),12=796/0-5-8 (min.0-1-8) Installation guide. Max Horz 1=155(LC 11) Max Upliftl=-94(LC 12),17=-153(LC 12),12=-104(LC 12) Max Grav1=698(LC 21),17=1692(LC 1),12=802(LC 22) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-749/0,2-24=-912/223,3-24=-805/243,3-25=-670/183,4-25=-588/206,4-5=-631/212,5-26=-5/198,6-26=-5/198, 6-7=401/216,7-27=-401/216,8-27=-401/216,8-9=-707/239,9-28=-668/223,10-28=-752/201,10-29=-149/70, 11-29=-194/55,11-12=-194/72 BOT CHORD 1-19=-1621775,18-19=-80/519,17-18=-80/519,16-17=0/59,6-17=-1065/239,15-16=-151/33,14-15=-97/663, 13-14=-97/663,12-13=-135/675 WEBS 3-19=-306/149,4-19=-114/406,5-19=-63/158,5-17=-846/144,6-15=-129/888,7-15=-230/89,8-15=-471/81,8-13=-200/158 ,9-13=-130/462,10-13=-175/134,10-12=-787/174 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 9-11-0,Exterior(2)9-11-0 to 12-9-14,Interior(1)26-10-14 to 39-94 zone;end vertical right exposed;C-C for members and forces&MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 94 Ib uplift at joint 1,153 Ib uplift at joint 17 and 104 Ib uplift at joint 12. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job--- -j ruT ss--- - --- JT'russ ype Qty [Ply__ TI7 853670 T09 Roof Special 7,1 --�. Job Reference(optional). Builth Component Su _-- -- --- -- -- Building po Supply,Green Cove Springs,FL Run.7.620 s Apr 30 2015 Print 7.620 s Apr 30 2015 MiTek Industnes,Inc. Fri Jan 15 08:13:13 2016 Paggee 1 I D:x9 n V I bBfQsyW522OBfFblzyMue3-XAKOq VI NslJz2vOBd EvXMBxT6gkVovFQnE Rjv7zvl32 K r 5-1-4 +_ 9-11-01-4-1 18-6-8 r _23-54_ 28-4-0 _ 29-10-1 349-3 _- - 39-11-0 _ - -}--14 5-1-4 4-9-12 -5.1 7-1-12 4-10-12 � 4-10-12 1-6-74 446-5-- Scale -13 Scale=1:72.5 5x6= 5x6- 5x6= 5x6= 7.00 F12 4 5 3x6= 4x5= 2x4 '! 10 28 6 7 Ta 8 29 3g 2x4 26 31 4x5 3 \. 11 25 V02 -,T6 32 ^� 4x5 '1 2x4 1 2 12 m — - - 1 \ 2 20 3319 34 18 -- 3 36 . 0-5-8 0-1-8) 3x8- 3x4 0-5-8q( 2-0) 16 14 0-5$y 1-8) 6 3x6- 1691#7,-146# 802 -07# 2x4 II 3x8 3x6- 3x8= 3x5 = 9-11-0 18-2-12 18¢-8 23-5-4 29-10-14 39-11-0 9-11-0 - - 8-3.12 0-3712 4-10-12 -- -- 6-5-10 + 10-0-2 Plate Offsets(X,Y)- [10-2-0,0-0-21_j13:0-2-4,0_1-8] [18:0-34,0-2 _ - LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) -0.24 13-14 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(TL) -0.61 13-14 >412 180 BCLL 0.0 Rep Stress Incr YES WB 0.69 Horz(TL) 0.02 18 n/a n/a BCDL 10.0 Code FBC2014TPI2007 (Matrix-M) - Weight:259 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-M oc purlins, except BOT CHORD 2x4 SP No.2`Except* end verticals. 133:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3 6-0-0 oc bracing:16-17. OTHERS 2x4 SP No.3 WEBS Web Brace:Length(member)6-9-11(5-18); SLIDER Left 2x6 SP No.2 1-6-0 - - � M(Tek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer .. REACTIONS. (Ib/size) 1=694/0-5-8 (min.0-1-8),18=1691/0-5-8 (min.0-2-0),13=796/0-5-8 (min.0-1-8) Installation guide. Max Horz1=155(LC 11) Max Upliftl=-98(LC 12),18=-146(LC 12),13=-107(LC 12) Max Grav 1=698(LC 21),18=1691(LC 1),13=802(LC 22) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-749/0,2-25=-912/226,3-25=-806/246,3-26=-670/187,4-26=-588/209,4-5=-626/234,5-27=-63/187,27-28=-63/187, 6-28=-63/187,6-7=-63/187,7-8=-426/234,8-29=-426/234,29-30=426/234,9-30=-426/234,9-10=-710/257, 10-31=-694/233,11-31=-764/211,11-32=-151/69,12-32=-195/55,12-13=-195/72 BOT CHORD 1-20=-161/787,20-33=-62/551,19-33=-62/551,19-34=-62/551,18-34=-62/551,17-18=0/85,7-18=-1094/258, 16-17=-153/37,16-35=-68/627,15-35=-68/627,15-36=-68/627,14-36=-68/627,13-14=-135/674 WEBS 3-20=-307/148,4-20=-155/450,5-20=-151/181,5-18=-849/118,8-16=-272/105,9-16=-388/45,9-14=-240/168, 10-14=-155/510,11-14=-177/134,7-16=-120/845,11-13=-785/184 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.ll; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 9-11-0,Exterior(2)9-11-0 to 114-12,Interior(1)284-0 to 39-94 zone;end vertical right exposed;C-C for members and forces&MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 98 Ib uplift at joint 1,146 Ib uplift at joint 18 and 107 Ib uplift at joint 13. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard o cussn,T—ssT — nd i - - — -— ------7s—TY—Pe � TPIy 'The Cumberla8536TO IT10 Hip 1 1 Building Component Sup y,Gre _LJob Reference(optionen Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 WTek Industries,Inc. Fn Jan 1-5108—:13;1-3 2016—Page--1 ID:x9nV1 b8fQsyW522OBfFblzyMue3-XAKOqVINslJz2vOBdEvXMBxTIgkXotNQnERjv7zvB2K 570-15 _+ 9-10-0 14-2-7 + 18-6-8_ _ 24-3-9 30-0-10__ 34-10-1 3911-0 5-0-15 4-9 7 4 4 1 4-4-1 5.9 1 5-9 1 - - 49-7 - 5-0.15- � Scale=1:68.4 5x6= 3x4= 4x5= 3x6 -= 3x4- 5x6 7.00.12 4 25 5 26 27 6 7 6 28 29 9 2x4 �\ � 4x5 ! N 3 N ^ 24 10 30 7 9 45 1 2 �\ 2x4 II \1 - -- 0 $ 19 1831 32 17 = IQ 007i���#) 3x8= 3x6= 0-5-8{W2-1) 19 13 0 1-8) 1733#/-131# 36 81 - 2x4 i 3x4= x — 3x8= (g1 a4# 94076 18-2-12 1 8 24-3-9 30-0.10 39-11-0 9-10-6 -4-- 0 3-12 5-9.1 5-9-1 9-10-6 Plate Offsets(X,Y)_ [1:0-2-0,0-0-2],_[4:0-3-0,0-1-12],[9:U-3-0,0-1-12] 0-2-4,0-1.8-] [17:0-3-8,0-2-4] LOADING(psf) SPACING- 2-0-0 CSI. DEFL in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Vert(LL) -0.25 12-13 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(TL) -0.63 12-13 >403 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.81 Horz(TL) 0.02 1 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:245 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-"oc purlins, except BOT CHORD 2x4 SP No.2*Except* end verticals. 63:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3 6-0-0 oc bracing:15-16. SLIDER Left 2x6 SP No.2 1-6-0 MiTek recommends that Stabilizers and required cross bracing REACTIONS. (Ib/size) 1=704/0-5-8 (min.0-1-8),17=1674/0-5-8 (min.0-2-1),12=804/0-5-8 (min.0-1 8)In Iinstalled during truss erection,in accordance with Stabilizer nstallation guide. Max Horz1=155(LC 11) Max Upliftl=-1 06(LC 12),17=-131(LC 12),12=-114(LC 12) Max Grav1=707(LC 21),17=1733(LC 17),12=811(LC 22) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-767/0,2-24=-926/260,3-24=-821/279,3-4=-682/243,4-25=-551/241,5-25=-551/241,5-26=-119/194,26-27=-119/194 6-27=-119/194,6-7=-471/269,7-8=-471/269,8-28=-614/261,28-29=-614/261,9-29=-614/261,9-10=-767/260, 10-30=-150/68,11-30=-194/54,11-12=-193/71 BOT CHORD 1-19=-176/782,18-19=-37/318,18-31=-37/318,31-32=-37/318,17-32=-37/318,16-17=0/127,6-17=-971/237, 16-33=-126/40,15-33=-126/40,15-34=-59/439,14-34=-59/439,13-14=-59/439,12-13=-154/681 WEBS 3-19=-311/160,4-19=-9/170,5-19=-10/434,5-17=-717/135,6-15=-155/858,8-15=-572/165,8-13=-2/260,9-13=-6/173, 10-13=-174/135,10-12=-794/214 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.11; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 9-10-6,Extedor(2)9-10-6 to 35-8-6,Interior(1)35-8-6 to 39-94 zone;end vertical right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 106 Ib uplift at joint 1,131 Ib uplift at joint 17 and 114 Ib uplift at joint 12. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard i Jori -- -- --truss —� rusT-S Type 7777--� �ly The Cumberland o 853670 711 Hip 1 1 _ Job Reference(optional) 2015 Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 Print7.820 s Apr 30 2015 FATek Industries,Inc. Fri Jan 15 08:13:14 2016 Page 1 ID:x9nVIbBfQsyW5220BfFblzyMue3-?Nu02ri?d3Rgg3zNBxQmvPUeWE4cXJ320uAGRazvB2J 11-3-9 18-6.8 _ 23-7-0 _+ 28_7-7 34-1-8 39.11-0 5-9-8 - 5-0 0 7-2-15 5-0-8 5:6-8 5 6 0 Scale=1:68.4 5x6= 3x6= 4x5= 2x4 !i 4 24 25 5 6 267 27 28 8 5x6 7.00 V2 \ 2x4 4x5 3 g 4.5 i 23 29 3x4 11 °D 1 2 10 I -7 0 IIC 18 30 17 31 16 Ia' Jq 699#f1d) 3x4= 3x6= 0-58(02-2) 14 3x4- 0_56p-1-8) 1 1800#/-105# 3x6= 80/4127# 2x4 i' 3x8= _._9-5-0 18-2-12 1 8 23-7-0 31-7-4 39-11-0 9-5-0 - 8-9-12 0-3-12 5 0 8 - 8-0-4 8-3 12 Plate Offsets X,Y)- -3-0,0 1 10],[4•.0 4-0,072741 (8:0-3-00 1-1 16:0-3-8,Edge] T �- LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) -0.2516-18 >881 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.76 Vert(TL) -0.4816-18 >463 180 BCLL 0.0 Rep Stress Incr YES WB 0.85 Horz(TL) 0.02 11 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:244 Ib FT=20% - - --- LUMBER- BRACING- -- - - - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-M oc purlins, except BOT CHORD 2x4 SP No.2"Except* end verticals. 133:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3 6-0-0 oc bracing:14-15. OTHERS 2x4 SP No.3 T-Brace: 2x4 SP No.3-6-16 SLIDER Left 2x6 SP No.2 1-6-0 WEBS T-Brace: 2x4 SP No.3-4-16,8-14 Fasten(2X) T and I braces to narrow edge of web with 1 Od(0.131'x3") nails,bin o.c.,with 3in minimum end distance. Brace must cover 90%of web length. MiTek recommends that Stabilizers and required cross bracing - be installed during truss erection,in accordance with Stabilizer - REACTIONS. (Ib/size) 1=694/0-5-8 (min.0-1-8),16=169210-5-8 (min.0-2-2),11=796/0-5-8 (min.0-1-8) Installation guide. - Max Horz 1=171(LC 11) Max Upliftl=-120(LC 12),16=-105(LC 12),l l=-127(LC 12) Max Grav1=699(LC 21),16=1800(LC 17),11=809(LC 18) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-634/0,2-23=-903/269,3-23=-777/292,3-4=-689/283,4-24=-129/249,24-25=-129/249,5-25=-129/249,5-6=-129/249, 6-26=418/283,7-26=418/283,7-27=418/283,27-28=418/283,8-28=-418/283,8-9=-861/315,9-29=-139/94, 10-29=-189/77,10-11=-203/92 BOT CHORD 1-18=-176/776,18-30=-50/431,17-30=-50/431,17-31=-50/431,16-31=-50/431,15-16=0/83,6-16=-1103/254, 15-32=-159/16,14-32=-159/16,14-33=-62/498,13-33=-62/498,13-34=-62/498,12-34=-62/498,11-12=-150/701 WEBS 3-18=-325/172,4-18=-21/525,4-16=-780/93,6-14=-111/861,7-14=-282/128,8-14=-324/38,8-12=-50/427,9-12=-215/157, 9-11=-837/192 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=5.Opsf;BCDL=5.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 11-3-9,Exterior(2)11-3-9 to 34-3-1,Interior(1)34-3-1 to 39-94 zone;end vertical right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 120 Ib uplift at joint 1,105 Ib uplift at joint 16 and 127 Ib uplift at joint 11. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 8)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard i TheCumbedand 853670 712 Hip 1 1 Building Component Soppy,Green Cove Springs,FL Run:7.620 Job Reference(optional) s Apr 30 2015 Print:7.620 s Apr 30 2015 PAek Industries,Inc.Fri Jan 15 08:13:15 2016 Page 1 ID:x9n V I bBfQsyW 5220 BfFblzyM u e3-TZSmFB mdONZh HCYalex?RcOrQeNMGsDjFYwgzOzvB21 23-11-8 18-7-8 21-3-8 22-10-7 6S1 18-11 15.11-8 7 9 11 7 27-2-5 334-15 3911-0 6&1 6 2 9 3-2-13 1 14-014-01 14-0 -1- 1-10.13 6-2.9 6S1 Scale=1:79.9 3x6= 0-2-15 14-0 3x6= 5x6= 9 10 12 13 16 17 19 l 5x6- 7 20 5x6 _ 4 s 5x6 7.00 12 2 23 3x4 3 24 0, 44 38 39 4x5 12 25 0 2 33 4032 41 31 )Ir' Jq 702AW 0-5-8(0-1-8) H# 3x4= 3x6= 10838a 1& 29 27 807 15# ���e 17� 4x5= 3x8= 3x6- 3x4= 4x6= 95-0 18-2-12 1 27-25 334-15 39.11-0 95 0 8-9-12 12 &7-13 6 2-9 6.6-1 Plate Offsets(X,Y)- [1:0-3-0,0-1-10],[4:0-3-0,0-1-12],[5:0.3-8,0-3-01,[10:0-3-0,0-1-121,[17:0-3-0,0-1-12],[18:0-5-0,0-2-0],[22:0-2-8,030],123:0-3-0,0-1-121,[24:0-1-12,0-1-8], [27:0-1-12,0-1-8],[30:0-2-0,0-2-0] [31:0-4-4,0-2-0] LOADING(psf) SPACING- 2-0-0 CSI. �- DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) -0.3231-33 >712 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.92 Vert(TL) -0.5431-33 >415 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.47 Horz(TL) 0.02 1 n/a n/a BCDL 10.0 Code FBC2014fTP12007 (Mat rix-M) Weight:289 Ib FT=20% LUMBER- BRACING- --- TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-6-0 oc purlins, except BOT CHORD 2x4 SP No.2"Except" end verticals. 63:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3 2-2-0 oc bracing:30-31. OTHERS 2x4 SP No.3 T-Brace: 2x4 SP No.3-11-31 SLIDER Left 2x6 SP No.2 1-6-0 WEBS T-Brace: 2x4 SP No.3-4-31,18-30,24-29 Fasten(2X) T and I braces to narrow edge of web with 10d(0.131'x3") nails,6in o.c.,with 3in minimum end distance. Brace must cover 90%of web length. JOINTS 1 Brace at Jt(s):11,18,6 MTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 1=688/0-5-8 (min.0-1-8),31=1703/0-5-8 (min.0-2-3),26=790/0-5-8 (min.0-1-8) Max Horz 1=-199(LC 10) Max Upliftl=-1 14(LC 12),31=-182(LC 12),26=425(LC 12) Max Grav1=702(LC 21),31=1838(LC 17),26=807(LC 22) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=-625/0,2-38=-895/238,3-38=-766/254,3-4=-730/270,4-5=-146/202,5-6=-247/214,6-8=-247/214,8-11=-247/214, 11-14=-253/220,14-15=-253/220,15-18=-253/220,18-21=-667/288,21-22=-067/288,22-23=-555/255,23-24=-638/253, 24-39=-753/223,25-39=-920/204,25-26=-746/198,5-7=0/176,7-9=0/171,9-10=0/154,17-19=0/100,19-20=0/190, 20-22=-5/198,10-12=0/122,12-13=0/127,13-16=0/127,16-17=0/127 BOT CHORD 1-33=-166/797,33-40=-25/357,3240=-25/357,32-41=-25/357,31-41=-25/357,30-31=-97/844,11-31=407/155, 3042=-29/261,4243=-29/261,2943=-29/261,28-29=-123/722,27-28=-123/722,26-27=-27/87 WEBS 3-33=-357/180,4-33=-53/625,4-31=-694/94,18-30=-775/151,18-29=-14/462,23-29=0/138,24-29=-385/133, 24-27=-55/131,25-27=407/658,13-14=41/25,15-16=-64/26,18-19=-182/50,20-21=-104/71,11-12=-253/95,8-9=-56/0, 6-7=-91/63 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=S.Opsf;BCDL=S.Opsf;h=25ft;B=45ft;L=40ft;eave=5ft;Cat.II; Exp B;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-11-14,Interior(1)3-11-14 to 17-7-9,Extedor(2)17-7-9 to 26-6-14,Interior(1)27-2-5 to 39-94 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are 2x4 MT20 unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 114 Ib uplift at joint 1,182 Ib uplift at joint 31 11, Co8�5ort ogja�t joint 26. �— The Cumberland . o nd33 Truss Ply 8536T0 T12 Hip — 1 1 Job Reference(optional) Building Component Supply,Green Cove Springs,FL Run:7.620 s Apr 30 2015 Print:7.620 s Apr 30 2015 UTek Industries,Inc. Fri Jan 15 08:13:15 2016 Page 2 ID:x9nVl bBfQsyW522OBfFblzyMue3-TZSm FB and ONZh HCYalex?RcOrQeNMGsDj FYwq zOzvB21 NOTES- 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 9)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10)Waming:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: 1637 Atlantic Beach Drive,• Atlantic Beach, FL 32233 Permit Number: Legal Description Lot 7 Atlantic Beach Country Club Unit 1 67-52-08-2S-29E.152 Parcel Floor Area of Sqq.Ft. S .Ft Valuation of Work S 255,817 Proposed Work heated/cooled 2,125 non-heated cooled 540 Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/pro osed structure(s) (circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed? (Circle one): N/A Florida Product Approval# See attached For multiple products use product approval form Describe in detail the type of work to be performed: New Residential Construction Property Owner Information: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May Avenue f E C ISO V °'i City Ponte Vedra State FL Zip 32081 Phone 904 217-0739 I {-- E-Mail or Fax#(Optional) arogers@tollbrothers.com t p - Contractor Information: CONTRACTOR EMAIL ADDRESS: aro ers toll q o ers.��t►�i 4 2016 Company Name: Toll Bros., Inc. Qualifying Agent: Steven R. Merten Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904 217-0739 Job Site/Contact Number 904 386-6472 Fax# State Certification/Registration# CGC 1510225 Architect Name &Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6)months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work, Plumbing, Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 1 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The grantin of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state, or local law regulating construction or the per ormance of construction. Signature of Owner Signature of Contractor Print Name Steven R.Merten,Division Sr.Vice President Print Name Steven R. Merten Before me Before me,— this e—this 3� a of Februa 2016 this—3 av of Februa 2016 Notary u is Not lic Revised 01.26.10 =dalloSta ISSA LIEBERPJIANMMISSION FF055605 'a e<;:, MELISSA LIEBERMAN ternber 18.2017MY COMMISSION#FF055605 ES Sep jridallotaryService.com ';FOFK o?; EXPIRES September 18.2017 1-�07i s98-0!53 Floridallotaryservice.com