Loading...
1810 ATLANTIC BEACH DR - NEW HOME PERMIT 0 CITY OF ATLANTIC BEACH _ J 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 \ INSPECTION PHONE LINE 247-5814 �O.i19r SINGLE FAMILY DWELLING NEW MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFR-257 Job Type: SINGLE FAMILY RESIDENCE Description: NEW HOME -DRIVEWAY Estimated Value: $450,000.00 Issue Date: 2/24/2016 Expiration Date: 8/22/2016 PROPERTY ADDRESS: Address: 1810 ATLANTIC BEACH DR RE Number: None GENERAL CONTRACTOR INFORMATION: Name: RIVERSIDE HOMES OF N FL Address: 414 OLD HARD RD STE 502 MATTHEW ROBERTS Phone: - - PERMIT INFORMATION: UTILITY DEPT.: PUBLIC WORKS: Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. All concrete driveway aprons must be 5" thick, 4000 psi, with fibermesh from the edge of pavement to the property line. Reinforcing rods or mesh area not allowed in the right-of-way. Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. All silt must remain on-site during construction. Roll off container company must be on City approved list and container cannot be placed on City Right- of-Way. (Approved: Advanced Disposal, Realco, Republic Services, Shappel's and Waste Pro.) Full right-of-way restoration, including sod, is required. IF A:IS APPROVED ONLY IN ACCORDANCE WI III ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. r 6' ; '' '` `�'� CITY OF ATLANTIC BEACH js1 i. • f 800 SEMINOLE ROAD -, j °' ;� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 \O.F119 r ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $765.00 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $1,530.00 STATE DCA SURCHARGE $22.95 STATE DBPR SURCHARGE $22.95 SEWER SDC-SYSTEM DEV CHG $4,050.00 WATER CONNECT/TAP & METER $370.00 WATER CROSS CONNECTION $50.00 WATER SDC-SYSTEM DEV CHG $1,140.00 Total Payments: $8,100.90 PERMIT IS AI'PROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 1 Doc # 2016026195, OR BK 17450 Page 2020, Number Pages: 1, Recorded 02/04/2016 at 08:19 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 NOTICE OF COMMENCEMENT 1 PREPARE IN DUPLICATE) Tax Folio No 169505 -1610 State Permit ate Of f County of DUVAL FLORIDA F To whom It may concern: The undersigned hereby Informs you that Improvements will be made to certain real property, and In accordance with Section 711 of the Florida Statutes, the following Information Is stated In this NOTICE OF COMMENCEMENT. Legal description of property being improved: 67-132 08- 2S -29E .153 ATLANTIC BEACH COUNTRY CLUB UNIT 2 LOT 63 Address of property being Improved: 1810 ATLANTIC BEACH DRIVE ATLANTIC BEACH, FL 32233 General description of improvements: NEW CONSTRUCTION - SFR owner WILLIAM H NATTER JR , M///.G' /A/44 A, 40 Address 59 SLEEPY HOLLOW ROAD, ANNAPOLIS, MD 21401 -1074 Owner's Interest in site of the improvement Fee Simple Titleholder (if other than owner) Name Address Contractor MATTHEW ROBERTS ( RIVERSIDE HOMES OF NORTH FLORIDA INC. Address 12276 SAN JOSE BLVD, #120, JACKSONVILLE, FL 32223 t Phone No 9C4-603-7055 Fax No. ' t Surety (if any) Address Amount of be $ Phone No. Fax No. Name and address of any petson making a loan for the construction of the improvements. i Name Address f Phone No. Fax No. 7 Name of person within the State of Florida, other than himself. designated by or upon whom notices or other documents may be served: Name Address Phone No Fax No. t r In addition to himself, owner designates the following person to receNe a copy of the Lienor's Notice as provided in Section 713.06 (2) (b). Florida Statutes. (Fill in at Owner's option). I Name RIVERSIDE HOMES OF NORTH FLORIDA, INC. Address 12276 SAN JOSE BLVD #120, JACKSONVILLE, FL 32223 f Phone No. 904-5034055 Fax No. Expiration date of Notice of Commencement (the expiration date is one (1) year from the date of recording unless a different date Is specified): , � / THIS SPACE FOR RECORDER'S USE ONLY 19 � /Vat'. / � "r, "/��/�C ��, /e,/��- _ MtE • �2�/ eetr enM r1Ns 2:_i dipaf 7 =t1 2b1 Lf mot A I"' M' ilimnwnwa.oa.amnumerali «,rtd � I //, ` i s �f,[ /� !l Ste . CwntY d . t My co Public al a Largo, Stets of l J L'L M: eISy On e xpiraa: 7 U a P r duwd .rdfx Notary a m 1. Notary na Cynthia Sheckells ve., l t Comm. Expires: 2/14/18 u , •, a. • Anne Arundel County, MD :r ''CO'? 1!'. Y 4 1 +,0eaewe, ..lw, , , 17 ; 00-9, 25M K \ ;2gE? >leo22! 1- 6/(!2 `, }!§ ;J \ § a■ � 4 :el:l : a Zaa0 *a (\ § | 4 }( !gaga A§ k§ %6 �t^ z !§ {! " ` ; )\/� k _ _ ! ! g - �2 )§ «({'� § ) \ , r §� £ , }\ \ ] n ,-7, 0:,g \ } ] i&EE , , ; ; , als2, 7 / { \ } E $} Q ! \ g ■!) w kEE\' � ( _a% 2 , `m!»x:i.£ F ! ®!!`!!!k»»_, k F!�! § - : / _% - _ ) CCC ` 2 o L2/ } E \Eg(� 0 \ }}\\ % ! 11 ) - S _M .-5k : 73 - 5 M 1 335M 9107 WI§ - _ _ 0 - \])� ( - _ ; E! N § * - , - ;;f ` � ! /§\; : a ` J. : _ , m . i \}2 \ / W� � ( \}/ R4 ( \ \ >0,“ /� i, \ } \5' /} '12 E\) ;! W/ ƒ\\ (} . \ _ i, , } � g \ 0 f ( i �> , ■ � m . 0. z nn } _! e �_x.\ . k\ }) \' 2 - £! \ }} _ 0 \ m ? }} . 13 (} no \ \ \� \\ \ _ 0 2 ` ({(} `` \ ( ) § } §�§ I - vc l o C ' W Ny n1 m a_ mnv W r.»a p ?ma 5 mx N 0 p w o IoW X10 N N -.r �m ,'(m ON A +O� A x) CN x C m $ 3 O c D _N m o on <m O N N 9N unA O l 1 o A Om o _° C O O c m m ° °n 5 '° If O 1 I D ° o nv S_ Y g q'2.- x o m a o ° . S n 3 v 3 nm %. 014= 8P5-1 ' 3 Z A m n m o v c °w o m ti 2 o = ' ° o n n3 -.p5 O - v a a _ > Au m nO 3 o c m o y m _ m nm n kaki O c w w 3 '- O g 38 3 v Nm N a g w w O m Z I 21. nog R O d O o g o d _ C N I� 21 n rt v ° m 1 n m ° ° H -4 n m rn m G 0 m w v N xt 2° oS- Z m ° Z o N Ji1ji n -9 u O cO I11 m Z.a w Co z I °i ,�-� 3GZZ zz Kz m-+zz.zzzz m- 3 v+ zzf.zf�z zzzzf.zzzzzz�zcn z iO m '0 /n m S no = 'DD D➢ 1 Y uci w DDDD DD➢ w H 1 � D➢➢DDo 'D >D'DD➢DDDD'D'➢D D 'D o aa J = !,,, ,,,,u = N. w N. p 3 no 3 - 3 9 w D z d 3 3 O � '. mo " a.< m a w O nn D V, - N 2 N O a -1 C z I O sm ° rv1 3 m l m C r r D O :72;. r a m m n°<' 7n a',."3 m N 5' a°i m w m m > > -n w n -. y =_E n ° 9 O 0 m_c m.o u xr3 m A3 n 0 $ n 0 0 0 ° ° 3 ° 3N H °. y 0 N ? a o. r Om!-r n 'O C n X233 m m o -�3 a 1 5 '° N �n 0 3 v n H N Q A -° 5 V ..4 P 3 R- m y -,D w 0 W n N m A _? `2g 3 m g A n ? o o H m o Q o r m - 3 -a a ^ 3 y 3 v N O E - 5 9 _ a , = 5 o ,< a c Q o n° a r o m v - °m' w < ° EE T -002, O D Y g a j° o° oV n g°a i s -m -69 w 2 ' = ° a N a J° ?a - m o 0 o g a 3 9 3 3 n 6 ° O n O m • w w w ° c a m °c `° 9 `^ E'ry £ °m �° 3'n 3 -' w N w 2 w o - a a m a j X O N 4 a O a n. N y a - 52_z -2 2 m 5 a• m m n e . y.➢ 2 2 4 R 8 0 8 ;D ao N N o iii a ° 9 ° mp 9 O ° i t.6 '' "6 n O 6 E F_. c - - - Win° 0 0 °' 'c^ n o a d =.m° - un c°i m d y ° 3 m° m° m m S ;,.-6.w' m n a m 5 r R n a m °x a m 3 5 . 2 c O o 0 0 0 N m N n 0 -I m° n m ?m _(0 J O m m T 8 Q z o a a"" 3 ba R m o ° n 3 m C V c N 3 3 3 w a n m E E m ° - T T. n n - m m 0 O O C w 2 Z5 fA 0 w w 0 Z D n n > >4 D O > > 'e• 'w m a a _ a�p w w R. m m a m o 0 0 O O '$i v V 9 9 F. a y £ �E_, j ?. .C Z N 9 < 3 D oo D m A s O 3 3 m a m N N N °n v W A O J J V J N _ > N A pwwN -.0' D . A u r O n I _ _ I I l I _. :: ri PUBLIC UTILITIES 1200 Sandpiper Lane �!psi S c;%° ATLANTIC BEACH,FL 32233 (904)270-2535 or(904) 247-5874 NEW WATER/SEWER TAP REQUEST Date: 2-- 4 1—/6 Project Address: /9/0 A 7„ T7 j - No. of Units: Commercial Residential r Multi-Family New Water Tap(s)&Meter(s) 3/ ” p( ) ( ) Meter Size(s) � New Irrigation Meter IV Upgrade Existing Meter from to (size) New Reclaimed Water Meter Size ,, / 3�y New Connection to City Sewer ✓ Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# no -SFR - 2 5-7 Water System Development Charge $ I, NO, OD Sewer System Development Charge $ y;ti sp , 00 Water Meter Only $ /e5" pp Reclaimed Meter Only $ /BS,00 Water Meter Tap $ Sewer Tap $ (notes) Cross Connection $ 50, oD Other $ TOTAL $s‘,io , OD APPROVED: Kayle Moore,PE / - (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED ,s rs--�myz„ City of Atlantic Beach ;`-•6 • '--' Building Department APPLICATION NUMBER 4 , s) 800 Seminole Road (To be assigned by the Building Department.) �� `'� Atlantic Beach, Florida 32233-5445 s'�� _ Z Phone(904)247-5826 • Fax(904)247-5845 �v;il9� E-mail: building-dept @coab.us Date routed: 2ff City web site: http://www,coab.us APPLICATION REVIEW AND TRACKING FORM Property Addres • Ao M4,4., LiA... De artmen Department review required q ed Yes No Applicant: I V1(51.6 !a)Es tanning &Zonin. Project: , / '�II istrator 44 a a • . A:.u• • tilities Public Safety • Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: :------- Date: .1-740‘. TREE ADMIN. Second Review: []Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: DApproved as revised. ❑Denied. Comments: Reviewed by: Date: tevised 07/27/10 1 1 1 01 A J• ti City of Atlantic Beach °4 C Building Department APPLICATION NUMBER 4 ..�s 800 Seminole Road RECEIVED (To be assigned by the Building Department.) 5V r Atlantic Beach, Florida 32233-5445; FEB 0 v Phone(904)247-5826 • Fax(904)247-5845 2016 ��/G 2�� 74111/111107, E-mail: building-dept @coab.us City web-site: http://www.coab.us By: Date routed: 2177 APPLICATION REVIEW AND TRACKING FORM / Property Addres • fi a i n •C 1 1 De•artment review required _ No Applicant: _— i VV( 7 a f -A m�S :,�"' o -- r'arming &Zoning on Project: / _____ istrator _ ��,rub tilities — = Public Safety 1111 Fire Services - Review fee $ Dept Signature Other Agency Review or Permit Required Review rowe Receipt -- of Permit Verified B Date Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers _- Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco - Other: — APPLICATION STATUS Reviewing Department] First Review: ❑Approved. Denied. (Circle one.) Comments: fG #14141,/ BUILDING T'�"✓ PLANNING &ZONING > ` Reviewed by: !4' yj � TREE ADMIN. Date: 6 Second Review: Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY I Reviewed by: Date: FIRE SERVICES Third Review: --- ❑Approved as revised. Denied. 1 Comments: - Reviewed by: ------ --- --— — _ Date: tevised 07/27/10 Js 0LANr,�, . City of Atlantic Beach r Building Department APPLICATION NUMBER ' . } 800 Seminole Road �EIV�� D (To be assigned by the Building Department.) ,v - ., Atlantic Beach, Florida 32233-5445 FEB 0 _ S'�� �? Phone(904)247-5826 • Fax(904)247-5845 3 �QI6 Pionit• E-mail: building-dept @coab.us By.— Date routed: Z� ' City web-site: http://www.coab.us ----__ _ APPLICATION REVIEW AND TRACKING FORM Property Addres • U i a Mqn.A'G , Department review required q Yes No .:nib Applicant: I VI(�i a ins - arming &Zonin i 'r:of istrator Project: i1 t 4 Wo , �O'ub' tilities� Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. (Circle one.) Comments: / Denied. ✓Gi j �l tz/0( 4"f/4 BUILDING 1 PLANNING &ZONING 1�/' ,l !� Reviewed by: �'� Date: 6/6 TREE ADMIN. Second Review: (Approved as revised. ❑Denied. PUBLIC WORKS Comments: JO 4 4G'1�//��, 1004 cek 6 PUBLIC UTILITIES f� PUBLIC SAFETY Reviewed by: tic Date: Z A 1 Jl 4 FIRE SERVICES Third Review: UApproved as revised. ODenied. Comments: Reviewed by: Date: 2evised 07/27/10 i 0 `!r,,, City of Atlantic Beach APPLICATION NUMBER j 11 Building Department (To be assigned by the Building Department.) :1 800 Seminole Road : ,,_� sce _ 25 -1 Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept @coab.us Date routed: 2/45-//‘, City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Addres • ko ' dAciA... Department review required Yes No Applicant: V�/��'! a - arming &Zonin Ate , 1 -- 's u istrator Project: !N f-4 m� �'y1 I&a /4 . 41'ubli tilitie� Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: o C." BUILDING PLANNING &ZONING c 8/ Reviewed by: Date: // /6 TREE ADMIN. Second Review: lijApproved as revised. ❑D ied. PUBLIC WORKS Comments: PUBLIC UTILITIES • PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 .is,-0-tviy., ' City of Atlantic Beach . A ..;1� Building Department APPLICATION NUMBER 1+L�_f i 800 Seminole Road`EWE �� To be assigned by the Building Department.) 4 J c.,' .'y't) u` - Atlantic Beach, Florida 32233-5445 , — s'ce - 25'7 Phone(904)247-5826 • Fax(904)247-'':45 FEB 0 3 2016 Azartis)` E-mail: building-dept @coab.us City web-site: http://www.coab.us Date routed: Z, APPLICATION REVIEW AND TRACKING FORM Property Addres •• Ao Mgn�'G Li/A. Department review ew re uired Yes No Applicant: VEr� b lays ..„,....... - arming &Zonii rimer:a istrator Project: , /7) .,a 4 WO , I'ub• tilities Public Safety • Fire Services Review fee $ co Dept Signature ,L Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI TION STATUS Reviewing Department First Review: pproved. ['Denied. one.) Comments: BUILDING PLANNING &ZONING �' ��� �, J Reviewed by: /4 —— P ' " 'Date: 2/r111 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. e!J'.Llt WCjRKS Comments: PUBLIC TILITIES PUBLI SAFETY • Reviewed by: Date: FIRE SERVICES Third Review: ]Approved as revised. ❑Denied. Comments: Reviewed by: Date: tevised 07/27/10 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH OFFICE COPY 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904)247-5845 Job Address: /8(0 4-f-1 af\i C 3 � 1 c. , 33permit Number:/6- srfl-c S 17 1D?-l32. 041-25-24E .153 ( ko L. Legal Description 02)0 t� C f 2 Lot Lo3 Parcel# I(, F 5 - 16110 FIoor ea o Sq.Ft. q. t Valuation of Work$ 46' 0042 Proposed Work heated/cooled 2-7c Z non-heated/cooled g i4 ________., Class of Work(circle one): t w Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial •esiden '• If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No QN/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed:N Qu..) C S J st- wC0( J - 5 F, .. Property Owner Information: • 1 , , Name: �11 C 1 Otl'Yl NCA -4g- Address: 5q 3i� P �o/iDLA c•L City >�NNQIbb/iS Sta eal t1Zip..)1 40 1 Phone b -- ¢i�(7 E-Mail or Fax#(O?tional) h ij A..l .ev- (c?I-'-zv t/.,i e I Contractor Information: Company Name: f�1 vex S1C1Q 44)O(Y1QS Quali ing Agent: rn -4-hQx_J Qpkef-{-S Address: (2a7(1) aJ' Q V311/41.:::1 e-*-1 4210 City ONViI 1-e State 1CL Zip Sad i Office Phone 904'. ')3.'1 Job Site/Contact Number Spt,MR Fax# N IA State Certification/Registration# CMC (15 4c 35 Architect Name&Phone# 1.1 FL— D.2J �IV I me . • 0l4. aLP •3 319 Engineer's Name& Phone# lie_ _' .a, " ■,:, 110,64 - ,00 Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certi that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months or i construction or work is suspended or abandoned for a period of six f6)months at any time alter work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs,Wells,Pools,Furnaces,Boilers,Heaters,Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certfy that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specifi d herein or not. The ranting of.a permit does not presume to give authority to violate or cancel the provisions of any oche edeera,state,or local law regulating constructio o the pe ormance o cons' i—on _._ Signature of Owner: 1 . �i G%L(rL/�( Signature of Contractor: / 'l? !7• ,4 Ji Print Name: N10.1411pt\J RD'�(t ` tint Name: LU/LL ij NIA-17-b2.- to and subscribed before me Sworn to and subset' ed before me th' 2�s�Day of aura- ,201 this Day of IL ..1,_. ' -L. ,2011e ■o,•ry u. tc 1ot7'� • Ic , .... �•,/ Got,,,,,. gyp. : z//'/ZDi�S , 1 ..., . 4 UNQs€r M.BISHOP Nat p •$tats of Floridra 1,G,� ,✓LE 0� ewe/Dv ,/�,I� (.../1. Con don a1 fF 916201 �,Llrivacd�(.��(/IQ � '1":"‘" • My Comm.Eplms Jan 19,2020 T Arrl�i ; ► _ �� 1 , DO NOT WRITE BELOW- OFFICE USE ONLY Applicable Codes: 2010 FLORIDA BUILDING CODE Review Result (circle one): Approved Disapproved Approved w/ Conditions Review Initials/Date: II? a 8 i 6 Development Size OFFICE COPY Habitable Space ?9a.S'.F Non-Habitable T7'1 S. P. Impervious area Miscellaneous Information Occupancy Group R-3 Type of Construction V Q Number of Stories Zoning District cc Jr7 G((,6 Max. Occupancy Load Fire Sprinklers Required Flood Zone X Conditions/Comments: I ,. , OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RIVER2792-West Indies(Mod) Builder Name: Riverside Homes Street: 18l D At T art,(-f a-4-h Dr\v-t" Permit Office: City of Atlantic Beach City,State,Zip: Atlantic Beach,FL,3. 33 Permit Number: Owner: Natter Residence Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(3166.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 2866.40 ft� b.Frame-Wood,Adjacent R=13.0 235.00 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=19.0 65.00 ft' 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2213.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=22.0 1982.00 ft' 6. Conditioned floor area above grade(ft') 2792 b.Knee Wall(Unvented) R=0.0 231.00 ft2 Conditioned floor area below grade(ft') 0 c. N/A R= ft2 11.Ducts R ft2 7. Windows(412.8 sqft.) Description Area a.Sup:Attic,Ret:Attic,Al-I:Attic 6 558.4 a. U-Factor: Dbl,U=0.35 412.83 ft2 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 48.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 48.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 5.903 ft. Area Weighted Average SHGC: 0.220 14.Hot water systems a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (2792.0 sqft.) Insulation Area EF:0.820 a.Slab-On-Grade Edge Insulation R=0.0 1982.00 ft' b. Conservation features b.Floor Over Other Space R=0.0 810.00 ft' None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.148 Total Proposed Modified Loads: 67.82 PASS Total Baseline Loads: 72.35 I hereby certify that the plans and specifications covered by Review of the plans and :''F'CKE STq?�•, this calculation are in compliance with the Florida.Energy specifications covered by this 'b,.;� :;.s ..,0�,`:: Doug u g a s R. Digitally signed by Douglas R. '',.1,•.; Code. Stickles calculation indicates compliance yi, DN:cn=Douglas R.Stickles,c=US, with the Florida Energy Code. ,m„ ''•:, .,;,•',;..0 ; PREPARED _��c nnactP«►+var,ins Before construction is completed f t:4 = -. DATE: Date:2016.02.0115:28:18-05'00' this building will be inspected for 0`.: j a e compliance with Section 553.908 . *' d.,.9.• . •� I hereby certify that this building, as designed, is in compliance Florida Statutes. �S with the Florida Energy oje. OWNER/AGENT: ►t -B1 BUILDING OFFICIAL: ill DATE: 2041 & DATE: aR /j/I (p - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 1/29/2016 2:11 PM EnergyGauge ■USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: RIVER2792-West Indies(Mod Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 2792 Lot# 63 Owner: Natter Residence Total Stories: 2 Block/SubDivision: Atlantic Bch CC #of Units: 1 Worst Case: No PlatBook: Builder Name: Riverside Homes Rotate Angle: 270 Street: Permit Office: City of Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 1 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume - 1 Block/ 2792 27110 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 1982 19820 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 810 7290 No 2 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 209.9 ft 0 1982 ft' ____ 0.2 0.8 0 2 Floor Over Other Space 2nd Floor _— ____ 810 ft' 0 0.15 0.85 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2382 ft' 0 ft2 Light 0.6 No 0.9 No 22 33.7 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1982 ft' N N 1/29/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Unvented) 1st Floor 0 1172 ft2 0.11 Wood 2 Under Attic(Unvented) 2nd Floor 0 810 ft2 0.11 Wood 3 Knee Wall(Unvented) 2nd Floor 0 231 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt To Wall Type Space R-Value Ft In Ft In Area- R-Value Fraction-Abcor Grade% 1 N=>W Exterior Frame-Wood 1st Floor 19 16 9 10 167.5 ft' 0.23 0.75 0 2 E=>N Exterior Frame-Wood 1st Floor 19 7 9 10 77.5 ft2 0.23 0.75 0 _ 3 N=>W Exterior Frame-Wood 1st Floor 19 23 6 12 282.0 ft2 0.23 0.75 0 4 E=>N Exterior Frame-Wood 1st Floor 19 16 6 12 198.0 ft' 0.23 0.75 0 5 N=>W Exterior Frame-Wood 1st Floor 19 4 6 10 45.0 ft2 0.23 0.75 0 6 E=>N Exterior Frame-Wood 1st Floor 19 13 9 10 137.5 ft' 0.23 0.75 0 7 N=>W Exterior Frame-Wood 1st Floor 19 5 10 50.0 ft2 0.23 0.75 0 8 E=>N Exterior Frame-Wood 1st Floor 19 6 6 10 65.0 ft2 0.23 0.75 0 9 S=>E Garage Frame-Wood 1st Floor 13 23 6 10 235.0 ft2 0.23 0.01 0 10 S=>E Garage Frame-Wood 1st Floor 19 6 6 10 65.0 ft2 0.23 0.01 0 11 S=>E Exterior Frame-Wood 1st Floor 19 5 10 50.0 ft2 0.23 0.75 0 _12 E=>N Exterior Frame-Wood 1st Floor 19 6 6 10 65.0 ft' 0.23 0.75 0 _13 5=->E Exterior Frame-Wood 1st Floor 19 16 6 10 165.0 ft2 0.23 0.75 0 14 W=>S Exterior Frame-Wood 1st Floor 19 57 6 10 575.0 ft2 0.23 0.75 0 15 N=>W Exterior Frame-Wood 2nd Floor 19 16 6 9 148.5 ft2 0.23 0.75 0 16 E=>N Exterior Frame-Wood 2nd Floor 19 1 3 9 11.3 ft2 0.23 0.75 0 17 N=>W Exterior Frame-Wood 2nd Floor 19 5 6 9 49.5 ft2 0.23 0.75 0 18 E=>N Exterior Frame-Wood 2nd Floor 19 13 3 4 6 59.6 ft2 0.23 0.75 0 19 S=>E Exterior Frame-Wood 2nd Floor 19 12 9 9 114.8 ft' 0.23 0.75 0 20 E=>N Exterior Frame-Wood 2nd Floor 19 5 6 9 49.5 ft2 0.23 0.75 0 21 5=>E Exterior Frame-Wood 2nd Floor 19 5 6 9 49.5 ft' 0.23 0.75 0 22 E=>N Exterior Frame-Wood 2nd Floor 19 6 6 9 58.5 ft2 0.23 0.75 0 23 S=>E Exterior Frame-Wood 2nd Floor 19 16 6 9 148.5 ft2 0.23 0.75 0 _24 W=>S Exterior Frame-Wood 2nd Floor 19 33 3 9 299.3 ft' 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>E Insulated 1st Floor None .46 3 8 24 ft' 2 S=>E Insulated 1st Floor None .46 2 8 8 21.3 ft' 1/29/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.35 0.22 54.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 2 E=>N 2 Vinyl Low-E Double Yes 0.35 0.22 21.3 ft' 25 ft 2 in 1 ft 0 in Drapes/blinds None 3 N=>W 3 Vinyl Low-E Double Yes 0.35 0.22 12.5 ft2 13 ft 2 in 1 ft 0 in Drapes/blinds None 4 N=>W 3 Vinyl Low-E Double Yes 0.35 0.22 96.0 ft2 13 ft 2 in 1 ft 0 in Drapes/blinds None 5 E=>N 4 Vinyl Low-E Double Yes 0.35 0.22 25.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 6 E=>N 6 Vinyl Low-E Double Yes 0.35 0.22 16.0 ft' 1 ft 8 in 1 ft 0 in Drapes/blinds None 7 S=>E 13 Vinyl Low-E Double Yes 0.35 0.22 42.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 8 W=>S 14 Vinyl Low-E Double Yes 0.35 0.22 15.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 9 W=>S 14 Vinyl Low-E Double Yes 0.35 0.22 4.5 ft' 1 ft 8 in 1 ft 0 in Drapes/blinds None 10 W=>S 14 Vinyl Low-E Double Yes 0.35 0.22 37.5 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 11 N=>W 15 Vinyl Low-E Double Yes 0.35 0.22 15.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 12 E=>N 18 Vinyl Low-E Double Yes 0.35 0.22 15.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 13 S=>E 21 Vinyl Low-E Double Yes 0.35 0.22 9.0 ft' 1 ft 8 in 1 ft 0 in Drapes/blinds None 14 S=>E 23 Vinyl Low-E Double Yes 0.35 0.22 18.0 ft' 1 ft 8 in 1 ft 0 in Drapes/blinds None 15 W=>S 24 Vinyl Low-E Double Yes 0.35 0.22 25.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 16 W=>S 24 Vinyl Low-E Double Yes 0.35 0.22 7.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None GARAGE ✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 666.99972 ft' 384 ft2 64 ft 10 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000308 2259.2 124.03 233.25 .2924 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 48 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit split SEER: 14 48 kBtu/hr 1440 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.82 1 gal 60 gal 120 deg None 1/29/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 a FORM R405-2014 SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / Supply-- -- Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 558.4 ft Attic 139.6 ft Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [ ]Jan Feb ]Mar [ ]A r Ma [X]Jun (X]Jul X Au X]Se 1 ]Oct ]Nov Dec Heating [X]Jan [X Feb ;X]Mar [ ]Apr f i May [ ]Jun [ 'Jul Jul [ i Aug f ]Sep [ ]Oct [X]Nov [X Dec Venting [ 1 Jan [ Feb X]Mar [X]Apr [ May [ ]Jun [ ] Aug [ 1 Sep [X]Oct [X]Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) PM 80 80 78 78 78 78 78 78 7 78 80 80 78 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 66 1/29/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. , Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 2866.40 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 235.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=19.0 65.00 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=22.0 1982.00 ft2 6. Conditioned floor area(ft2) 2792 b.Knee Wall(Unvented) R=0.0 231.00 ft2 c. N/A R= ft2 7. Windows" Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.35 412.83 ft2 a.Sup:Attic,Ret:Attic,AK:Attic 6 558.4 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 48.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 48.0 HSPF:8.20 Area Weighted Average Overhang Depth: 5.903 ft. Area Weighted Average SHGC: 0.220 8. Floor Types Insulation Area 14.Hot water systems Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1982.00 ft2 a.Natural Gas EF:0.82 b.Floor Over Other Space R=0.0 810.00 ft2 b. Conservation features c. N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ••'' �I I st Construction through the above energy saving features which will be installed(or exceeded) ,oF "".....Ali''•`. in this home before final inspection. Otherwise, a new EPL Display Card will be completed ;'y4` ,,?.%. . '. to- based on installed Code compliant feature '1. " ..:''''/A."`o Builder Signature: �1�� �� Date: -7,17,1 ,(,, *.. a a Address of New Home: (9 10 Ail a"_;(_,-Rea al k.ye_ City/FL Zip: ��IA,I,�i'i(. ?kat ' 4 ............-7...JSC/`: !�' I cop�,,,E11.....:: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/29/2016 2:11 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: I Atlantic Beach,FL, MANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. o R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. o R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. o R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. o R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. I 1/29/2016 2:12 PM EnergyGauges USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., O R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies O R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. O R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. O R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 1/29/2016 2:12 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) o R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. o R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. o R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. o R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. o R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. o R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. o R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. o R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 1/29/2016 2:12 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: RIVER2792-West Indies(Mod) Builder Name: Riverside Homes Street: iO p -ia-44-fi C� Rj-ai J- Dr ► i-Q- Permit Office: City of Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Natter Residence Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. ✓ Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and ✓ framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently I y� attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity V spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. l/ Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available ✓ space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1/29/2016 2:12 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 Manual S Compliance Report Job: RIVER2792 p p Date: 01/29/16 IIIATIMG `coal/( Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonulle,FL 32256 Phone:904-722-8995 Fax:904-722-8944 Project Information For: Riverside Homes 12276 San Jose Boulevard, Suite#120, Jacksonville, FL 32223 Cooling Equipment Design Conditions Outdoor design DB: 93.0°F Sensible gain: 34544 Btuh Entering coil DB: 77.6°F Outdoor design WB:77.0°F Latent gain: 7018 Btuh Entering coil WB: 63.8°F Indoor design DB: 75.0°F Total gain: 41563 Btuh Indoor RH: 50% Estimated airflow: 1533 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0480000A+FB4CNP048L Actual airflow: 1533 cfm Sensible capacity: 33180 Btuh 96% of load Latent capacity: 10240 Btuh 146% of load Total capacity: 43420 Btuh 104% of load SHR: 76% Heating Equipment Design Conditions Outdoor design DB: 32.0°F Heat loss: 43713 Btuh Entering coil DB: 68.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0480000A+FB4CNP048L Actual airflow: 1533 cfm Output capacity: 46000 Btuh 105% of load Capacity balance: 32 °F Supplemental heat required: 0 Btuh Economic balance:-99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1533 cfm Output capacity: 10.6 kW 83% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Jan-29 14:37:27 . wrightsoft• Comfort Builder by Wrightsoft 15.0.22 RSU13256 Page 1 AC K ...side Homes\ATLANTIC BEACH CC\ABCC63(Natter).rup Cale=MJ8 Front Door faces: E Project Summary Job: R/29/1692 Date: 01/29/16 UtATIN4 �(OOIING Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax 904-722-8944 Pro'ect Information For: Riverside Homes 12276 San Jose Boulevard, Suite#120, Jacksonville, FL 32223 Notes: Lot 63,Atlantic Beach Country Club Natter Residence Desi• n Information Weather: Jacksonville, Intl Airport, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 50 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32391 Btuh Structure 21244 Btuh Ducts 11323 Btuh Ducts 13300 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 43713 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 34544 Btuh Method Detailed Latent Cooling Equipment Load Sizing Shielding 3 (partial) Stories 1 Structure 3550 Btuh Ducts 3468 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 2792 2792 Equipment latent load 7018 Btuh Volume (ft3) 26524 26524 Air changes/hour 0 0 Equipment total load 41563 Btuh Equiv.AVF (cfm) 0 0 Req. total capacity at 0.70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade 14 SEER PURON HP Trade 14 SEER PURON HP Model CH14NB0480000A Cond CH14NB0480000A AHRI ref 7835757 Coil FB4CNP048L AHRI ref 7835757 Efficiency 8.2 HSPF Efficiency 11.7 EER, 14 SEER Heating input Sensible cooling 32200 Btuh Heating output 45500 Btuh @ 47°F Latent cooling 13800 Btuh Temperature rise 27 °F Total cooling 46000 Btuh Actual air flow 1533 cfm Actual air flow 1533 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Jan-29 14:37:28 AC -Pl wrightsoft' Comfort Builder by Wrightsoft 15.0.22 RSU13256 Page 1 ..side Homes\ATLANTIC BEACH CC\ABCC63(Natter).rup Cale=MJS Front Door faces: E 14 I - Right-J®Worksheet Job: R1VER2792 Date: 01/29/16 OWING (onlir.c Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax 904-722-8944 1 Room name Entire House Whole House 2 Exposed wall 3 Room height 4 Room dimensions 345.3 ft 345.3 heat/cool ft 9.5 ft heacool 2792.0 x 1.0 ft 5 Room area 2792.0 ft' 2792.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft;°F) (Btuh/ft9 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WJ 12E-Osw 0.068 n 2.58 1.46 722 645 1667 943 722 645 1667 943 L-G 3A-2ov 0.350 n 13.30 9.78 77 0 1024 753 77 0 1024 753 12E-0sw 0.068 e 2.58 1.46 528 435 1124 636 528 435 1124 636 3A-2ov 0.350 e 13.30 13.71 69 27 918 946 69 14 918 946 11 11J0 0.600 e 22.80 18.36 24 24 547 441 24 24 547 441 W 12E-0sw 0.068 s 2.58 1.46 874 785 2028 1148 874 785 2028 1148 L-G 3A-2ov 0.350 s 13.30 1.78 89 178 1184 158 89 89 1184 158 W 12E-Osw 0.068 w 2.58 1.46 725 547 1413 800 725 547 1413 800 G 3A-2ov 0.350 w 13.30 13.71 178 71 2367 2440 178 35 2367 2440 F 12B-Osw 0.097 - 3.69 1.73 300 279 1028 482 300 279 1028 482 L_ p 11J0 0.600 n 22.80 18.36 21 21 479 386 21 21 479 386 P 16B-Oad 0.408 - 15.50 22.07 231 231 3581 5099 231 231 3581 5099 C 16X19-0ad 0.408 n 2.15 1.59 1982 1982 4265 3151 1982 1982 4265 3151 F 19A-19bscp 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tph 1.358 n 51.60 0.00 1982 209 10765 0 1982 209 10765 0 6 c)AED excursion 1943 1943 Envelope loss/gain 32391 19324 32391 19324 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 4 920 Appliances/other 1000 1000 Subtotal(lines 6 to 13) 32391 21244 32391 21244 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32391 21244 32391 21244 15 Duct loads 35% 63% 11323 13300 35% 63% 11323 13300 Total room load 43713 34544 43713 34544 Air required(cfm) 1533 1533 1533 1533 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wf i htSOft 2016-Jan-29 14:37:28 AC 9 Comfort Builder by Wrightsoft 15.0.22 RSU13256 Page 1 ...side Homes\ATLANTIC BEACH CC\ABCC63(Natter).rup Calc=MJ8 Front Door faces: E Building Analysis Job: RIVER2792 Date: 01/29/16 ALATItl6 '(00tING Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road.Suite#204.Jacksonville,FL 32256 Phone:904-722-8995 Fax 904-722-8944 Pro'ect Information For: Riverside Homes 12276 San Jose Boulevard, Suite #120, Jacksonville, FL 32223 Design Conditions Location: Indoor: (°F) Heating Cooling Jacksonville, Intl Airport, FL, US Indoor temperature ( F) 70 75 Elevation: 30 ft Design TD (°F) 38 18 Latitude: 31°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 11.5 50.0 Dry bulb (°F) 32 93 Infiltration: Daily range (°F) - 18 ( M ) Method Detailed Wet bulb (°F) - 77 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Heatin • Component Btuh/ft2 Btuh % of load Walls 3.7 10842 24.8 w,, „, Glazing 13.3 5493 12.6 Doors 22.8 1026 2.3 Ceilings 2.2 4265 9.8 Floors 5.4 10765 24.6 Infiltration 0 0 0 Ducts 11323 25.9 �nrg Piping 0 0 Humidification 0 0 Do,,. awes Ventilation 0 0 ca, Adjustments Total 43713 100.0 Coolin • Component Btuh/ft2 Btuh % of load rternal Walls 3.1 9107 26.4 Glazing 15.1 6240 18.1 Doors 18.4 826 2.4 Ceilings 1.6 3151 9.1 Floors 0 0 0 Infiltration 0 0 0 Ducts 13300 38.5 Ventilation 0 0 Internal gains 1920 5.6 Blower 0 0 G"""° Adjustments 0 Total 34544 100.0 Doors c.,.,,, Latent Cooling Load = 7018 Btuh Overall U-value = 0.211 Btuh/ft2-°F Data entries checked. 2016-Jan-29 14:37:28 -Pk wrightsoft° Comfort Builder by Wrightsoft 15.0.22 RSU13256 Page 1 ...side Homes 1ATLANTIC BEACH CC\ABCC63(Natter).rup Calc=MJ8 Front Door faces: E M ° r diet ig 1 ?., If li 4 i o 1A1 � !w 7. 8r ' Cg 3..1 s 1 A A A iii �S—......0 a.,...g.g..A Ad I \ i ill ss M——.. sc o. r x . a 1 � ti R 1.p a -q— --Rimer- w P $ 8R iii '� 1'C;! .' 1.� Et • 1 k 1 l s 7 w 1, k:: J !6� Z L24 8 0 _ . J Y Q 0 S I 6a `S y I Q 5.:.'g i J _, �� K ° — kl go a e f4� °te*. e OI '3� A-1 ( r --- _ l } —� 01 m 1. °L6 13 z , i: LI I■V ,..-,,,,iiv.„,„,,,,w,.0111.77:■41111;,, L, �B3 i 2. t t ......a. p Q....1 1 1.00 1 ...w.,1. I ..x K 1 0. j 1 .. a„ o. K N .d at • }0.i �=.m... � 0... 0..,65 a m. 1/.. Ili IF i 1 ' ::13 1 � 1. if 1 1 N R 11. - R —J g ■ d c a �' a �I;�1I [w 1 4,,i g ft S N I O . RI QQ s it g R : p LL es F.. t : p w z€ IPh it me ell g of Ji � li ' .0 e3 1