Loading...
312 4TH ST - REVISION FOR 310 4TH ST CITY OF ATLANTIC BEACH • _ f 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 V INSPECTION PHONE LINE 247-5814 RESIDENTIAL ADDITION MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-RADD-2521 Job Type: RESIDENTIAL ADDITION Description: INTERIOR REMODEL Estimated Value: $50,000.00 Issue Date: 3/2/2016 Expiration Date: 8/29/2016 PROPERTY ADDRESS: Address: 312 4TH ST RE Number: 169812-0000 PROPERTY OWNER: Name: HOLLOWAY ET AL. MARGARET M Address: 1200 OCEANFRONT GENERAL CONTRACTOR INFORMATION: Name: TURNKEY CONSTRUCTION RUBEN LAVARIAS Address: 5991 Chester AVE STE 105 Phone: - - PERMIT INFORMATION: PUBLIC WORKS: A Right-of-Way Permit must be obtained for use of (construction parking, if required). All concrete driveway aprons must be 5" thick, 4000 psi, with fibermesh from the edge of pavement to the property line. Reinforcing rods or mesh area not allowed in the right-of-way. Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. All silt must remain on-site during construction and silt fence must fully enclose work area. Roll off Container Company must be on City approved list and container cannot be placed on City Right-of-Way. (Approved: Advanced Disposal, Realco, Republic Services, Shappel's and Waste Pro.) Full right-of-way restoration, including sod, is required. IFEU$:IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. d' _1:* °S, CITY OF ATLANTIC BEACH --, J 800 SEMINOLE ROAD J ,a n s) Z ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ,..>----O131t)r BUILDING PERMIT FEE $300.00 STATE DCA SURCHARGE $4.50 ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $150.00 UTIL REV RESIDENTIAL BLDG $50.00 STATE DBPR SURCHARGE $4.50 STATE DCA SURCHARGE $4.50 STATE DBPR SURCHARGE $4.50 PLAN CHECK FEES $150.00 BUILDING PERMIT FEE $300.00 Total Payments: $868.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Regante 312 4th St Builder Name: t tzd i<C')/ cc i /- i/ r7/A//j Street: 312 4th Street Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL,32250- Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing Existing(Projecte 9. Wall Types(1896.0 sqft.) Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=13.0 1528.00 ft2 b.Frame-Wood,Common R=11.0 368.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (885.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 885.00 ft2 6. Conditioned floor area above grade(ft2) 1770 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(247.4 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 177 a. U-Factor: Dbl,U=0.33 247.40 ft' b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 177 SHGC: SHGC=0.30 b. U-Factor: N/A ft= 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 17.8 SEER:14.00 b.Central Unit 17.8 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.8 HSPF:8.20 SHGC: b.Electric Heat Pump 17.8 HSPF:8.20 Area Weighted Average Overhang Depth: 1.000 ft. (L a Area Weighted Average SHGC: 0.300 14.Hot water systems �C v 8. Floor Types (1770.0 sqft.) Insulation Area a.Electric Cap:4EF:iTgalloli 0.9� a.Slab-On-Grade Edge Insulation R=0.0 885.00 ft' b. Conservation features b.Floor Over Other Space R=0.0 885.00 ft2 None FEB 2 4 2016 c.N/A R= fy 15.Credits - CF,Ps Glass/Floor Area: 0.140 Total Proposed Modified Loads: 32.27 PASS Total Standard Reference Loads: 40.51 I hereby certify that the plans and specifications covered by Review of the plans and -••'' THE sr'4l''' this calculation are in compliance with the Florida Energy specifications covered by this '1..� `,;.. FO'': Code. � ,�' calculation indicates compliance ;'��,,, .,--.. 11.44,,e.: `, ,'Ile pia -rvic:-- with the Florida Energy Code. 4/,u,,, SO? u:, PREPARED BY: 4i<<• a" E3efore construction is completed l' 1 �Q' 7° DATE: __ _ 6/16%2015 _ this building will be inspected for �',.. 1 a,. compliance with Section 553.908 1. * -. I hereby certify that this building, as designed, is in compliance Florida Statutes. r' �►' :Y. ::,� = with the Florida Energy Code. %-..'•-'0i)tyEI4,,.••'� OWNER/AGENT:- -_ BUILDING OFFICIAL: �_ DATE: /A --- DATE: - � - Compliance requires completion of a Florida Air Barrier and Insulati&Tn nspection C r-ckl0 p - Compliance requires a roof absorptance test and a roof emittance to t in ac�• ', .r. i 4 6. THIS PLAN MUST BE ON JOB SITE FOR 6/16/2015 2:32 PM EnergyGauge®USA-FlaRes2010 Sectiorr4t `h�rl an�� r8 E CT I O e`� Page 1 of 6 PROJECT Title: Regante 312 4th St Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1770 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: `lea A%<<tY (_t'n'S" 1MA/IotateAngle: 0 Street: 312 4th Street Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Multi-family FL, 32250- New/Existing: Existing(Projected) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 885 7080 2 Block2 885 7080 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 885 7080 Yes 5 1 1 Yes Yes Yes 2 2nd Floor 885 7080 No 0 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Pen meter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 97 ft 0 885 ft2 ____ 0.6 0 0.4 2 Floor Over Other Space 2nd Floor ____ ____ 885 ft2 0 0.3 0 0.7 ROC1F Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Are Color Absor. Tested Tested Insul. (deg) 1 Flat Compositionshingles 888 ft2 38 ft' Light 0.85 Yes 0.8 Yes 0 4.8 ATTIC V # Type Ventilation Vent Rat o(1 in) Area RBS IRCC 1 No attic Vented 300 885 ft2 N N 6/16/2015 2:32 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Vaiue Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 885 ft2 0.11 Wood WAI.LS Adjacent Cavity Width Height Sheathing Framing Solar Below i# Omi At cent Type Space R-Value_ Ft In Ft In Area R-value Frartion Absor Grade% _ 1 W Exterior Frame-Wood Main 13 14 0 8 0 112.0 ft' 0 0.23 0.8 0 _ 2 N Exterior Frame-Wood Main 13 7 0 8 0 56.0 ft2 0 0.23 0.8 0 _ 3 E Exterior Frame-Wood Main 13 12.5 0 8 0 100.0 ft2 0 0.23 0.8 0 4 E Exterior Frame-Wood Main 13 17 0 8 0 136.0 ft' 0 0.23 0.8 0 _ 5 S Exterior Frame-Wood Main 13 18 0 8 0 144.0 ft' 0 0.23 0.8 0 _ 6 S Exterior Frame-Wood Main 13 12 0 8 0 96.0 ft' 0 0.23 0.8 0 _ 7 W Exterior Frame-Wood Main 13 16 0 8 0 128.0 ft' 0 0.23 0.8 0 _ 8 E Exterior Frame-Wood 2nd Floor 13 11 0 8 0 88.0 ft2 0 0.23 0.8 0 _ 9 E Exterior Frame-Wood 2nd Floor 13 6 0 8 0 48.0 ft' 0 0.23 0.8 0 _10 E Exterior Frame-Wood 2nd Floor 13 12 0 8 0 96.0 ft' 0 0.23 0.8 0 _11 S Exterior Frame-Wood 2nd Floor 13 10 0 8 0 80.0 ft' 0 0.23 0.8 0 _12 S Exterior Frame-Wood 2nd Floor 13 5 0 8 0 40.0 ft' 0 0.23 0.8 0 _13 S Exterior Frame-Wood 2nd Floor 13 14 0 8 0 112.0 ft' 0 0.23 0.8 0 14 W Exterior Frame-Wood 2nd Floor 13 14 0 8 0 112.0 ft' 0 0.23 0.8 0 _15 W Exterior Frame-Wood 2nd Floor 13 15.5 0 8 0 124.0 ft' 0 0.23 0.8 0 _16 N Exterior Frame-Wood 2nd Floor 13 7 0 8 0 56.0 ft' 0 0.23 0.8 0 17 N Neighbor Frame-Wood Main 11 23 0 8 0 184.0 ft' 0 0.23 0.8 0 _18 N Neighbor Frame-Wood 2nd Floor 11 23 0 8 0 184.0 ft' 0 0.23 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width In Ft Area n 1 N Insulated Main Metal .28 3 6.7 20.1 ft' WINDOWS Orientation shown is the ente.ed,Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 3 Vinyl Low-E Double Yes 0.33 0.3 40.2 ft' 1 ft 0 in 1 ft 0 in None None 2 E 4 Vinyl Low-E Double Yes 0.33 0.3 12.0 ft' 1 ft 0 in 10 ft 0 in None None 3 S 5 Vinyl Low-E Double Yes 0.33 0.3 40.2 ft' 1 ft 0 in 1 ft 0 in None None 4 W 7 Vinyl Low-E Double Yes 0.33 0.3 25.0 ft' 1 ft 0 in 10 ft 0 in None None 5 E 8 Vinyl Low-E Double Yes 0.33 0.3 25.0 ft' 1 ft 0 in 1 ft 0 in None None 6 E 9 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft' 1 ft 0 in 1 ft 0 in None None 7 S 11 Vinyl Low-E Double Yes 0.33 0.3 25.0 ft' 1 ft 0 in 1 ft 0 in None None 8 S 13 Vinyl Low-E Double Yes 0.33 3.3 25.0 ft' 1 ft 0 in 1 ft 0 in None None 9 W 15 Vinyl Low-E Double Yes 0.33 13 25.0 ft' 1 ft 0 in 1 ft 0 in None None 10 N 16 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft' 1 ft 0 in 1 ft 0 in None None 6/16/2015 2:32 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Best Guess .0003 1392.8 .6.46 143.8 .2844 5.9018 HEATING SYSTEM # System Type Subtype - Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 17.8 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:8.2 17.8 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 17.8 kBtu/hr 534 cfm 0.75 1 sys#1 2 Central Unit None SEER: 14 17.8 kBtu/hr 534 cfm 0.75 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SelPnt Conservation 1 Electric None Main 0.94 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Ceri # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS V ---Supply--- – Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 177 ft2 Main 44.25 ft Default Leakage Main (Default) (Default) 1 1 2 Attic 6 177 ft2 2nd Floor 44.25 ft Default Leakage 2nd Floor (Default) (Default) 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin ,]Jan r ]]Feb Mar [ r [ Ma (X]Jun [X]Jul X Au [X]Se [ ]Oct Nov Dec Heating 1 Jan V Feb )( Mar I .Apr r I May [ ]Jun I ]Jul 4 i Aug I ]Sep [ ]Oct Nov Dec Venting Jan [ ]Feb )( Mar IX r [ May [ ]Jun [ ]Jul [ Aug [ ]Sep [X]Oct X:Nov n Dec 6/16/2015 2:32 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 r ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/16/2015 2:32 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index, the more efficient the home. 312 4th Street, Atlantic Beach, FL, 32250- 1. New construction or existing Existing(Projecte 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=13.0 1528.00 ft2 2. Single family or multiple family Multi-family b.Frame-Wood,Common R=11.0 368.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 885.00 ft2 6. Conditioned floor area(ft2) 1770 b.N/A R= ft2 c.N/A R= ft2 7. Windows" Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.33 247.40 ft2 a.Sup:Attic,Ret:Main,AH:Main 6 177 SHGC: SHGC=0.30 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 177 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 17.8 SEER:14.00 SHGC: b.Central Unit 17.8 SEER:14.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 17.8 HSPF:8.20 Area Weighted Average Overhang Depth: 1.000 ft. b.Electric Heat Pump 17.8 HSPF:8.20 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 885.00 ft2 a.Electric EF:0.94 b.Floor Over Other Space R=0.0 885.00 ft2 b. Conservation features c.N/A R= ft2 None 15.Credits CF,Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building .•........••••........` . -flu srg Construction through the above energy saving features which will be installed (or exceeded) .• 04 .............._lE•o•: in this home before final inspection. Otherwise, a new EPL Display Card will be completed i co.-./Nip: ,;,.„... based on installed Code compliant fe•tures. :F'"'7„, k"°'..,..:?.,/,,,t-,` 0 t Builder Signature: /411r # - Date: b/ -V h3" : ce'- a a s ce Address of New Home: City/FL Zip: - - •.,COD... *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Regante 312 4th St Builder Name: Bosco Custom Homes Street: 312 4th Street Permit Office: Atlantic Beach City.State.Zip: Atlantic Beach,FL,32250- Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelop€ insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unveiled attic). knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and of subfloor decking. cantilevered floors) Air barrier is installed at aiy exposed edge of insulation. Crawl space walls Insulation is permanently :attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetra:ions, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit. or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed betwe, n outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them frcm the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in ccmmon wall between dwelling units. HVAC register boots HVAC register boots that K:enetrate building envelope are sealed to subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 SE:ction 405.4.1 Compliant Software FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 312 4th Street PERMIT#: Atlantic Beach, FL, 32250- MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must preveit supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to = R-2+ accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 6/16/2015 2:32 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6