Loading...
1390 BEGONIA ST - PW -ri•y` City of Atlantic Beach APPLICATION NUMBER ' • Building Department (To be assigned by the Building Department) ✓' 800 Seminole Road /cr464 /���' ' Atlantic BeachFlorida 32233 5445 J��L n : Zl�l'• I i ,,', Phone(904)247-5826 • Fax(904)247-5845 -' Email: building-dept @coati us Date routed —_��� /� City web-site http//www.coab.us --_-- - APPLICATION REVIEW AND TRACKING FORM Property Ad ss: /39 Q e c !R- r nt review required ` Yes No Applicant: /Yeti /1 4/)L.77 ;TiQ . Planning&Zonin._ n/( Wier: 'r ' trator L Project: ,C " I() /11 d r7)6. 4 Publi -- d ttlic Utilities 'ublic Safety T Fire Services Review fee $ Dept Signature Review or Receipt Other Agency Review or Permit Required of Permit Verified By Date Flonda Dept of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: I /Approved [V Denied. l (Circle one ) Comments: jet BUILDING �ti��iliej PLANNING&ZONING Reviewed by: C Date: 7A ,5' TREE ADMIN. Second Review: Approved as revised. I 'Denied PUBLIC WORKS Comments: see 1 ki, i `m k- PUBLIC UTILITIES `3 L/ �jy� /�,QC (,� r?"' PUBLIC SAFETY Reviewed by 4.---- Date: /* /S J FIRE SERVICES Third Review: [Approved as revised. Denied. Comments: /2t✓/S.EZ T 4 w,...) • 'A.;Eb ii/d' /S Reviewed by: C Date: /2 / �^ Revised 07/27/10 •;51J-14.r1,1 Comp. By: SRW Date: 11/24/2015 r Public Works Department City of Atlantic Beach Permit No: 15-S FR-1572 Address: 1390 Begonia Street Required Storaqe Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V= CAR/12 Where: V=Volume of Runoff C= Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area(A) = 7,162 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft2) "C" Wtd "C" Impervious 0 7,162 1.00 0.00 Pervious 7,162 7,162 0.20 0.20 Runoff Coefficient(C)= 0.20 Runoff Volume V= 0.20 x 7,162 x 9.3 / 12 V= 1,110 ft3 Postdevelopment Runoff Volume: Lot Area(A) = 7,162 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft) "C" Wtd "C" Impervious 3,015 7,162 1.00 0.42 %ISA = 42.1% Pervious 4,147 7,162 0.20 0.12 Runoff Coefficient(C)= 0.54 Runoff Volume V= 0.54 x 7,162 x 9.3 / 12 V= 2,979 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume- Predevelopment Runoff Volume DV= 2,979 - 1,110 DV= 1,869 ft3 Retention Begonia 1390 Revision 2 11/24/2015 Comp. By: SRW r J Date: 11/24/2015 Public Works Department City of Atlantic Beach Permit No: 15-SFR-1572 Address: 1390 Begonia Street Provided Storage: Elevation Area Storage (ft) 5.0 (ft2) (ft3) 750 0 BOTTOM 60 X 12.5 6.0 1,050 900 TOB 70 X 15 Elevation Area Storage (ft) (ft2) (ft) 5.0 75 0 BOTTOM 15 X 5 ! 6.0 192 134 TOB 16 X 12 Elevation Area Storage (ft) (ft) (ft3) 5.0 297 0 BOTTOM 33 X 9 6.0 640 469 TOB 40 X 16 Inground storage=A*d*pf A=Area= 1882.0 d=depth to ESHWT= 2.0 pf= pore factor= 0.3 Inground Storage= 1129.2 ft3 0 Required Treatment Volume= 1,869 ft3 0 Supplied Treatment Volume= 2,029 ft3 0 0 i I 0 i Retention Begonia 1390 Revision 2 11/24/2015 0