1390 BEGONIA ST - PW -ri•y` City of Atlantic Beach APPLICATION NUMBER
' • Building Department (To be assigned by the Building Department)
✓' 800 Seminole Road
/cr464 /���' ' Atlantic BeachFlorida 32233 5445 J��L n : Zl�l'• I i
,,', Phone(904)247-5826 • Fax(904)247-5845
-' Email: building-dept @coati us Date routed —_��� /�
City web-site http//www.coab.us --_-- -
APPLICATION REVIEW AND TRACKING FORM
Property Ad ss: /39 Q e c !R- r nt review required ` Yes No
Applicant: /Yeti /1 4/)L.77 ;TiQ . Planning&Zonin._
n/( Wier: 'r ' trator
L
Project: ,C " I() /11 d r7)6. 4 Publi --
d ttlic Utilities
'ublic Safety T
Fire Services
Review fee $ Dept Signature
Review or Receipt
Other Agency Review or Permit Required of Permit Verified By Date
Flonda Dept of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: I /Approved [V Denied. l
(Circle one ) Comments:
jet BUILDING �ti��iliej
PLANNING&ZONING Reviewed by: C Date: 7A ,5'
TREE ADMIN.
Second Review: Approved as revised. I 'Denied
PUBLIC WORKS Comments:
see 1 ki, i `m k-
PUBLIC UTILITIES `3 L/ �jy� /�,QC (,� r?"'
PUBLIC SAFETY Reviewed by 4.---- Date: /* /S J
FIRE SERVICES Third Review: [Approved as revised. Denied.
Comments:
/2t✓/S.EZ T 4 w,...) • 'A.;Eb ii/d' /S
Reviewed by: C Date: /2 / �^
Revised 07/27/10
•;51J-14.r1,1
Comp. By: SRW
Date: 11/24/2015
r
Public Works Department
City of Atlantic Beach
Permit No: 15-S FR-1572
Address: 1390 Begonia Street
Required Storaqe Volume
Criteria:
Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations
requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be
stored on site. Volume of Runoff is defined as follows:
V= CAR/12
Where: V=Volume of Runoff
C= Coefficient of Runoff
A=Area of lot in square feet
R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach)
Predevelopment Runoff Volume:
Lot Area(A) = 7,162 ft2
Runoff Coefficient
Area Lot Area
Description (ft2) (ft2) "C" Wtd "C"
Impervious 0 7,162 1.00 0.00
Pervious 7,162 7,162 0.20 0.20
Runoff Coefficient(C)= 0.20
Runoff Volume
V= 0.20 x 7,162 x 9.3 / 12
V= 1,110 ft3
Postdevelopment Runoff Volume:
Lot Area(A) = 7,162 ft2
Runoff Coefficient
Area Lot Area
Description (ft2) (ft) "C" Wtd "C"
Impervious 3,015 7,162 1.00 0.42 %ISA = 42.1%
Pervious 4,147 7,162 0.20 0.12
Runoff Coefficient(C)= 0.54
Runoff Volume
V= 0.54 x 7,162 x 9.3 / 12
V= 2,979 ft3
Required Storage Volume
DV= Postdevelopment Runoff Volume- Predevelopment Runoff Volume
DV= 2,979 - 1,110
DV= 1,869 ft3
Retention Begonia 1390 Revision 2 11/24/2015
Comp. By: SRW
r J Date: 11/24/2015
Public Works Department
City of Atlantic Beach
Permit No: 15-SFR-1572
Address: 1390 Begonia Street
Provided Storage:
Elevation Area Storage
(ft)
5.0
(ft2) (ft3)
750 0 BOTTOM 60 X 12.5
6.0 1,050 900 TOB 70 X 15
Elevation Area Storage
(ft) (ft2) (ft)
5.0 75 0 BOTTOM 15 X 5
! 6.0 192 134 TOB 16 X 12
Elevation Area Storage
(ft) (ft) (ft3)
5.0 297 0 BOTTOM 33 X 9
6.0 640 469 TOB 40 X 16
Inground storage=A*d*pf
A=Area= 1882.0
d=depth to ESHWT= 2.0
pf= pore factor= 0.3
Inground Storage= 1129.2 ft3
0
Required Treatment Volume= 1,869 ft3
0 Supplied Treatment Volume= 2,029 ft3
0
0
i
I
0
i
Retention Begonia 1390 Revision 2 11/24/2015
0