227 BEACH AVE - REVISION PERGOLA io CITY OF ATLANTIC BEACH
800 Seminole Road
. _ ` Atlantic Beach,Florida 32233
J yr Telephone(904)247-5800
FAX(904)247-5845
REVISION REQUEST SHEET
Date: q'2 c--15- Received by: Resubmitted:
Permit Number: 1. 73 24
I
Original Plans Examiner: Project Name: 600de4
Project Address: '44 6e4 64- Avg.
Contractor:/40r cr S Cam?-57/vd7i n2 Contact Name: C14.i's As�
Contact Phone : go 4- 494- 33 41 Contact e-mail: ( ,rr-S (Q r lo/a Ls. c�rGv . Goat
Revision/Plan Check/Permit Fee (s)Due: $ c!
Description of Proposed Revisiop to Existing Permit:
?e rav lu- tRa 4 S 64!L. 11,t j,14<" 7[4,4S
Additional Increase in Building Value: $ g, d0Q Additional S.F.
Site Plan Revised: Public W/U Approval:
By signing below. I(print name) 2-t t'i S f I -� affirm that the above revision
is incl 've the proposed changes.
V/Ci"l
4:1 :-.*I_E Signature of Contractor/ gent(Contractor must sign if increase in valuation) D j
Office Use Only I I 2015
Date: Approved: X Rejected: otified b Y• 1
Plan Review Comments:
_.Dep. 1 ent review required Yes No
B *2
—" arming&Zoning
-- = . -'- a or
Public Works
Plans Examiner
Public Utilities
Public Safety
Fire Services Date
Created 8120115 Rev.2
221 Ee4c<, Ave
Atit...._
Pevewit- it 14- 03 2 7
MCVEIGH&MANGUM pQy
E N G i N E E R l N G • I N C �_C
e F�G Mr.Jeff Lane,
Lane Architecture, P.A.
904 Margaret
Jac ksonvill e, Florida 32204 REVISION
904-355-9020 BP# /Gl—e, 3.2
7
• DATE Jo J;7 / 5
SIGNED p79.-
_ARE: Goodell Residence Pergola
MME# 12114
Dear Mr. Lane,
This letter concerns the pergola for the referenced project. Per FEMA, the pergola must be designed to
break free under the larger of the design wind load or 1Opsf. However, if the design loading exceeds
20psf, certification is required by a registered engineer that the structure will collapse under a water load
associated with a base flood event.The wind pressures for this location exceed 20psf.
The 100 year storm design grade for this location is EL5.5. The existing grade is at approximately
EL14.25. The bottom of the pergola posts are at approximately EL9.75. Therefore, the pergola will
collapse and break up at a flood load much weaker than the design base flood.
I certify the structure will collapse under a water load associated with a base flood event.
Sincerely, IL O B Y
•
THIS P., 14 MUST BE
H. n McVeigh,P.E.
Structural Engineer of Record ON B SITE FOR
EACH INSPECTION