Loading...
227 BEACH AVE - REVISION PERGOLA io CITY OF ATLANTIC BEACH 800 Seminole Road . _ ` Atlantic Beach,Florida 32233 J yr Telephone(904)247-5800 FAX(904)247-5845 REVISION REQUEST SHEET Date: q'2 c--15- Received by: Resubmitted: Permit Number: 1. 73 24 I Original Plans Examiner: Project Name: 600de4 Project Address: '44 6e4 64- Avg. Contractor:/40r cr S Cam?-57/vd7i n2 Contact Name: C14.i's As� Contact Phone : go 4- 494- 33 41 Contact e-mail: ( ,rr-S (Q r lo/a Ls. c�rGv . Goat Revision/Plan Check/Permit Fee (s)Due: $ c! Description of Proposed Revisiop to Existing Permit: ?e rav lu- tRa 4 S 64!L. 11,t j,14<" 7[4,4S Additional Increase in Building Value: $ g, d0Q Additional S.F. Site Plan Revised: Public W/U Approval: By signing below. I(print name) 2-t t'i S f I -� affirm that the above revision is incl 've the proposed changes. V/Ci"l 4:1 :-.*I_E Signature of Contractor/ gent(Contractor must sign if increase in valuation) D j Office Use Only I I 2015 Date: Approved: X Rejected: otified b Y• 1 Plan Review Comments: _.Dep. 1 ent review required Yes No B *2 —" arming&Zoning -- = . -'- a or Public Works Plans Examiner Public Utilities Public Safety Fire Services Date Created 8120115 Rev.2 221 Ee4c<, Ave Atit...._ Pevewit- it 14- 03 2 7 MCVEIGH&MANGUM pQy E N G i N E E R l N G • I N C �_C e F�G Mr.Jeff Lane, Lane Architecture, P.A. 904 Margaret Jac ksonvill e, Florida 32204 REVISION 904-355-9020 BP# /Gl—e, 3.2 7 • DATE Jo J;7 / 5 SIGNED p79.- _ARE: Goodell Residence Pergola MME# 12114 Dear Mr. Lane, This letter concerns the pergola for the referenced project. Per FEMA, the pergola must be designed to break free under the larger of the design wind load or 1Opsf. However, if the design loading exceeds 20psf, certification is required by a registered engineer that the structure will collapse under a water load associated with a base flood event.The wind pressures for this location exceed 20psf. The 100 year storm design grade for this location is EL5.5. The existing grade is at approximately EL14.25. The bottom of the pergola posts are at approximately EL9.75. Therefore, the pergola will collapse and break up at a flood load much weaker than the design base flood. I certify the structure will collapse under a water load associated with a base flood event. Sincerely, IL O B Y • THIS P., 14 MUST BE H. n McVeigh,P.E. Structural Engineer of Record ON B SITE FOR EACH INSPECTION 46,�t fig ti'G 1 ll1 Y'„„„f 2 �.. / : 0 OCT 2 7 2015 TA3T-6:7102: �; J ? I ; ;_A�5 �'�� "� STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL