1089 ATLANTIC BLVD /ATLANTIC SELF STORAGE - FIRE SPRINKLER PERMIT �' r - 'Is, CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD UV` - ;� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL FIRE SPRINKLER MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MCHF-2919 Job Type: MECHANICAL FIRE PERMIT Description: FIRE SPRINKLER Estimated Value: $94,000.00 Issue Date: 3/30/2016 Expiration Date: 9/26/2016 PROPERTY ADDRESS: Address: 1089 ATLANTIC BLVD RE Number: 177616-0000 PROPERTY OWNER: Name: ASHLAND INVESTMENT, INC. Address: 7880 GATE PKWY SUITE 300 GENERAL CONTRACTOR INFORMATION: Name: SOUTH FLORIDA FIRE PROTECTION LLC Address: 3602 29TH ST E BRADENTON FL 34208 Phone: - - FEES: Trade Permit Base Fee $55.00 State Mech DCA Surcharge $2.00 State Mech DBPR Surcharge $2.00 Total Payments: $59.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICA.. ! ► CITY OF ATLANTIC BEAC ,r) I '© r,: 800 Seminole Rd Atlantic Beach, FL 3223 ,' 4k; , ,° , 1 +-» " Ph (904) 247-5826 Fax (904) 247-5845 ` r "Li JOB ADDRESS: • - A I a., _• (ad. 1,I. 4JdR11I/ .. IV-l)- - WIN 7 PROJECT VALUE $ q("I) . ARI# fit'"..`'.:--, ! !riq� . ' i Air Handling Equipment Only Air Handling Unit & Condenser on 1 • -r Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM 'E UIRED FIRE PREVENTION FILE COPY y t Q ,Y r Y�{ n.l N Fire Sprinkler System Quantity (Requires 3 sets of plans) -"1 ; Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnace. Refrigerator Condenser BTU's # Water Heaters i1i r- 2 Q mn Solar Collection Systems LS V . Tanks (gallons) Wells OTHER: .I DEC l b 2015 1j) E© E D VE M IV/ IK4 11111 'ermit becomes void if work does •t commence within a six month period r work is suspended • b 1 Ion:.1' Z si .nt11O5ere.r T fy that I have read his application and know the same o .- . . . .. • G • • ' 'ons of I ws and ordinances g,S. 1 g this work will be compile hether specified or tot. The permit does not give authority to violate the provisions of any of er state or local law reg latio •• • '•1 or the erform. /w:/.■construction. Property Owners Name A 6.. v 0.1—S 1.. Phone Number Mechanical Company S.,.-3-N., Fto►-t d if�A2-mac Office Phon y,- eZ,28-9T�tl Fax Scoff-S11 9 �o. Address: $i 1'S��►�i r [� S: 3.eC City - + c StaWL- Zip3`!Z`10 License Holder (Print): c e r-1 ,t C,'•.si. State Certification/Registration #Firm- 00.201 VotarizectSigna ure [ n older ,o��ra Amy!Atti�eCos to =Commission#FF164887 Before me this I�.P day of &: 1:x[nt:.s: OCT 01 z41s �c c �,ti,b�� 20 "'''''''F`�•'. 1ST FLORIDA NOTARX LLC Signature of Notary Public ' 27•Cs/1°_.. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: IZWC\ rs/ 1C., ej1vC‘ • Permit Number:tS"{f� — Legal Description$- • .L2(t Parcel# cizov ( l Floor Area of Sq.Ft. Sq.Ft Valuation of Work$q4 l cot Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): atli Addition Alteration ' • lair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system insta 9 e one): Yes No N/A Florida Product Approval # For multiple products use product approval form Describe in detail the type of work to be performed: \CI \-`et\\►{13 (le� ' "N S fs ■01L�t✓ Property Owner Information: NameP6b\ftria vu.bAr ne t L _ it tdress: � G' w44 sieve 36� Citx�(�jnv e. State 1 Zip;�� Phone E-Mail or Fax# (Optional) Contractor Information: Compan Nam �{S(�\ T\re $ Yl Qualifying Agent: C\�1`(\ cif Address\1,g. tC�a(4 aAke. L Cit}15�CA�Yt�l `J State F L. Zip 3•4 LMMU Office Phoit l\ ' _Cj k 1 Job Site/Contact Numbeiltv.4.\)Z28-' ► Fax II�SIp�- � l State Certificatio _ egistration#VC, )C\M— 1 Architect Name&Phone# Engineer's Name& Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six 6)months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work, Plumbing,Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. Signature of Owner R//}YJ�y...y 4 $ Signature of Contractor 1("---- Print Name 4rejary� y Print Name ?.(eJ 6-110d7 t and subs+:cilzed before me Swo to and subsc 'bed before me this 1 ' Day of t��P , 20 1 G this c' Day of u•�,,..�.� ,20�� Notary P is �t':Commission#FF164887 'otary, ► tc (. . ' �''arie Crosby ' Expires:OCT Ol,2018 =Cot 3.54#, _ yy� ( ,,F�F164887 ' Oi `, BONDED THRU ti' 'a.T 01,2018 ,,,. 1ST FLORIDA NOTARZ LLC •N.,,opI ••,.'s BONDED THRU ••• 1ST FLORIDA NOTARY,i 1.: 1 LiV-` n /�9 JiS 1l:/ , OWNER'S AUTHORIZATION FOR AGENT r `1 a � 0 .0 is hereby authorized to act on behalf of a 1 • Y° -J _ - - - /ki,.the owner(s) of those lands described within the attached application, a d as described in the attached deed or other such proof of ownership as may be required, in applying to the City of Atlantic Beach, Florida, for an application related to a Development Permit or other action pursuant to: ❑ Zoning Variance ❑ Comprehensive Plan Amendment ❑ Use-by-Exception ❑ Zoning Map Amendment ❑ Building Permit n Plat, Replat or Lot Division Eli Sign Permit ❑ Tree Permit ■I Ot - BY: S'`', at it- o i wner Cr*∎d C/oSVI -> Print Name pfu....N, Signature o1Owner Print Name ` Telephone Number State of •kor i dl •■ County of tdt0-- -4tD. Signed and sworn before me on this I (.Q day of-De, T. By ( iCr..,A C/b41.1 Identification verified: AC•00 .j 4p „e.-m- Oath sworn: Yes No ir—......4.„..C. otary Signatur My Commission expires: IC- l --1 ":jiikk,, Amy Marie Crosby 01. '.4.4.. .,'"Expires:OCT01,2018 bk,�,o;.� BONDED THRU �,,,` 1ST FLORIDA NOTARY rar, StAkr.4„ City of Atlantic Beach wasp Building Department APPLICATION NUMBER - ~ 800 Seminole Road (To be assi d by the Building Depart t.) _r Atlantic Beach, Florida 32233-5445 /5 Y Nil 1. '7 Q PI Phone(904)247-5826 • Fax(904)247-5845 111111 (i o E-mail: building-dept @coab.us ,Z City web-site: http://www.coab.us Date routed: �j8 �s APPLICATION REVIEW AND TRACKING FORM Property Address: /a/91174,-04L Kira/ ' De ment review required quired Yes No 'Building Applicant: cDGt. rk,4/ Q�2L x—, 25 ?ariemytirt &Zoning Tree Administrator Project: A:gi, ,41rii). 'Fr' .SystElvi Public Works Public Utilities Public Safety dire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept.of Environmental Protection — Florida Dept.of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: — — . ___ _APPLI TION STATUS Reviewing Department First Review: Approved. (Circle one.) ❑Denied. Comments: BUILDING PLANNING &ZONING /� Reviewed by: ! /�oo� Date: �fl�L TREE ADMIN. Second Review: °Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: —_ Date: FIRE SERVICES Third Review: °Approved as revised. °Denied. Comments: Reviewed by: Date: Revised 07/27/10 MECHANICAL PERMIT APPLICA CITY OF ATLANTIC BEAC '1 :,._, 800 Seminole Rd Atlantic Beach, FL 3223 , �-' r Ph (904) 247-5826 Fax (904) 247-5845 F. F"° "' r' ' JOB ADDRESS: i ` 1 a.,.1; t✓d• 64E/141104 i / -1 r, uF41-! PROJECT VALUE $ (21(4 .2. ARI# , _Air Handling Equipment Only Air Handling Unit & Condenser on r Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Duct Systems: Total CFM Seer Rating REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Duct Systems: Total CFM Seer Rating REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's ALL OTHER GAS PIPING Elevators/Escalators Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnace. # Water Heaters Refrigerator Condenser BTU's npft Solar Collection Systems I ' `' u V Tanks (gallons Wells ) ETHER: ' DEC 4 0 2015 ©[ D bE finummommILVI IK4 11111 ennit becomes void if work does ot commence within a six month period •. work is suspended b 1 •on. Ti Si i n • is application and know the same o It, . < . - z • • isions of 1 ws and ordinances � -r a com lie : hether that I have read ot. The permit does not give authority to violate the provisions of any ot er state or local g g this work will be'erfor a onstru specified or Ilawr • I reg latio • '•• a r the perform. e-f. construction. P. on. t operty Owners Name A I,..- _ "0/ -h.........-.1-$ 1 _ 'hone Number Mechanical Company �lo,,t d ,� R���Arlee1, .r. Office Phon 1 e228-411141 Fax Sb7-S-719 'o. Address: 811 I eSk.a 1 k;r C- Sl,.4-c C City et r o-t,-C• State- Zip3`IZ`!J icense Holder(Print): r....,,t Go 44% State Certification/Registration#FFCN- oaDo Totarizett i, na ire r e ios ey older 'r°•�'•��':�mmi.��FF164$87 :i:: .j: .,. si n#F �1 4887 Before me this I(.P day of �� flecv b 1S - iy�OFFw�;' , o'di?Iii:TilRtl � P/✓ 20 '•Rona` 1ST FLORIDIANOTARY,LLC Signature of Notary Public - -7■0e-N c_74-?j, °fin. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: 1CACk ,'lIQ(( �. 9:_:■\Vd , Permit Number:iS.CPA)— 2,C1 '�- Legal Descriptio ..:- ' 2 �$�' Parcel #ci' k +tLD oor • rea o q. t. Valuation of Work$cA4 00.0 Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): et, Addition Alteration • •'air Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system insta a 9 • e one): Yes No N/A Florida Product Approval # For multiple products use product approval form Describe in detail the type of work to be performed: \C' Ct\Iic (\et -1e_ sqc ct.\e✓ Property Owner Information: 1 r Name: 1 rat. 1 .. + a • •d ess: j &'f 3 Cit ,\a\ e Stat- 1 Zip t Phone E-Mail or Fax#(Optional) Contractor Information: (�,,,�� �,, Company Name f,Aa 1C f\C 1'!�]�ttilo'.:_Qualifying Agent: C\. Cif Address 1111difl ttAk t awv€ L Cit CQi r State F L. Zip L4Z) Office Phoi�E-L41\ $-�$4 I Job Site/Contact Numbe p `�' State Certification/Registration#'5CQG4- 1 ��'I�l\� Z�$'�ibzt 1 Fax IC�SIp�r 'S��°� Architect Name& Phone# Engineer's Name& Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6)months at any time after work is commenced. /understand that separate permits must be secured for Electrical Work, Plumbing, Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby ertify that i have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. C� C Signature of Owner ��� 4 �� Signature of Contractor � � Print Name .4.rtyty Ray g4. l Print Name A/4,/ 6,0t Swor _ and subs:rilZed before me Swo to and subsc 'bed before me his P Day of J� t.-rb�� , 20 1 S this ic Day of •Le-42... ,20" jak 'Jotary PIP is :... ,e; rie Crosb �a' . . •.Lo`:Commission#FF164887 otary •lic .41...: .a•�n..4�;e-Expires:OCT 01,2018 LSSiO #FF l '' pF�b�, BONDED THRU ter 1 201& •, 1ST FLORIDA NOTARY,LLC SONDED T 01�ZO18 HRU OWNER'S AUTHORIZATION FOR AGENT i . " 0.■ Cr 47 l'al is hereby authorized to act on behalf of _ � •at . Igo . - -J - / hi,•the owner(s) of those lands described within the attached application, a d as described in the attached deed or other such proof of ownership as may be required, in applying to the City of Atlantic Beach, Florida, for an application related to a Development Permit or other action pursuant to: ❑ Zoning Variance ❑ Comprehensive Plan Amendment ❑ Use-by-Exception ❑ Zoning Map Amendment ❑ Building Permit ❑ Plat, Replat or Lot Division ❑ Sign Permit El Tree Permit U/ Otl - BY: S'`' at S! o ■wner Cra`of CioS" Print Name jj vil..:‘, Si nature of Owner ny 1 Print Name `i-ti-ZZ f-S cqt _ Telephone Number State of C.kor , of •• County of frt �•-•••-+c-e„ Signed and sworn before me on this i LQ day of,201c. By C'll e r %a 1.ra$10 Identification verified: lka.p,,,� _ Oath sworn: Yes No €--...–.4...C.0.4"--)._ otary Signatur My Commission expires: 10-- % —1 "'v�' „ �,,N4•.�a�; Amy Marie Crosby E 4.i. =Commission#FF164887 E°a�t 1`'1`�.r,�=Expires:OCT 01,2018 \S.;6V ,, .•, BONDED THRU •"•„„, 1ST FLORIDA NOTARX F.►.c , City of Atlantic Beach APPLICATION NUMBER Building Department J, � ;') 800 Seminole Road (To be assig d b the Build g Depart t.) � Atlantic Beach, Florida 32233-5445 Mt✓ t• Z { 7� Phone(904)247-5826 • Fax(904)247-5845 "�dj;;19r E-mail: building-dept @coab.us Date routed: /2 /8 iS City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: /i /'9 /174/1/7 /Alai De ent review required N Yes No Bui din Applicant: D(,t. FM 4/ dec.. : ?a - &Zoning /;: Tree Administrator iei, 49/-11).Proj ect: /e1Fr � SrEM Public Works Public Utilities Public Safety ire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified B Date Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: 62 Mfg I!) TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: 0Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 --------- - HYDRAULIC CALCULATION Fire Sprinkler Reports for Atlantic Self Storage 1089 Atlantic Blvd. Atlantic Beach, FL. 32233 j _oki1iIIti//,��4 Digitally signed by �� �'"M' 4:-7/: '' c V /i James M. Curtis — Na.3 . Date: 2015.07.19 =-�oX/ �` bF , TATS OF ,�o ` '23:27:21 -04'00 ' '• r•' P`. '''///ass ON - ,N1. Prepared By: Phillip Roe South Florida Fire Protection 9522 Melody Circle Port Charlotte,FL 33981 941-228-9541 7/18/15 Design Area#1 r Is Fire-Fire Sprinkler Hydraulics Calculation Program ��� Elite Software Development,Inc. Phillip Roe TO- Hydraulic Calculation. Burlington,KY 41005 - - Page 2_, General Project Data Report 1 General Data Project Title: Hydraulic Calculation Project File Name: South Florida Fire Protection - Atlantic Self Storage - DA1..fiw Designed By: Phillip Roe Date: 7/18/15 Code Reference: NFPA 13 Approving Agency: Local A.H.J. Design Area#1 Client Name: Atlantic Self Storage Phone: Address: 1089 Atlantic Blvd. City, State Zip Atlantic Beach, FL 32233 Code: Design Area#1 Company Name: South Florida Fire Protection Representative: Phillip Roe Company Address: 9522 Melody Circle City And State: Port Charlotte, FL 33981 Phone: 941-228-9541 Building Name: Atlantic Self Storage Building Owner: Contact at Building: Phone at Building: Address Of Building: 1089 Atlantic Blvd. City, State Zip Atlantic Beach, FL 32233 Code: Design Area#1 Project Data " g Description Of Hazard: Ordinary 2 Sprinkler System Wet Type: Design Area Of Water Application: 923 ft2 Maximum Area Per Sprinkler: 130 ft2 Default Sprinkler K-Factor: 5.60 K Default Pipe Material: SCHED 40 WET STEEL Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 250.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: Viking Model: VK300 Size: 1/2" Temperature Rating: 155 F Water Supply Test Data A. Source Of Information: Test Hydrant ID: Date Of Test: 7/18/15 Hydrant Elevation: 0 ft Static Pressure: 50.00 psi Test Flow Rate: 1145.00 gpm Test Residual Pressure: 30.00 psi Calculated System Flow Rate: 600.21 gpm Calculated Inflow Residual Pressure: 33.44 psi Available Residual Pressure At 43.95 psi System Flow: ;Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.00 psi Minimum Desired Flow Density: 0.20 gpm/ft2 Number Of Active Nodes: 81 Number Of Active Pipes: 93 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 14 Number Of Inactive Sprinklers: 0 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®a a9AltiltiWB, 2015, 9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Phillip Roe (l Hydraulic Calculation Burlington,KY 41005 „.r• Page 3 is `Fire Sprinkler Output Data Overall Pipe Output Data Beg. Nodal Spk/Hose Residual Nom. Dia. q tr;11,1-1 F. L./ft Pipe-Len. PF-(psi) Elevation (psi/ft) Fit-Len. End. KFactor feet Discharge Pressure Inside Dia. PE-(psi) Node (K) ( ) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 1 8.00 30.30 25.37 10.06 1.00 25.37 0.20220 1.00 0.607 101 0.00 29.30 0.00 11.10 1.049 25.37 E 2.00 0.433 SCHED 40 WET STEEL 120 9.42 0 3.00 1.040 2 8.00 30.30 24.59 9.45 1.00 24.59 0.19082 1.00 0.572 102 0.00 29.30 0.00 10.45 1.049 24.59 E 2.00 0.433 SCHED 40 WET STEEL 120 9.13 0 3.00 1.005 3 8.00 30.30 25.29 9.99 1.00 25.29 0.20094 1.00 0.603 103 0.00 29.30 0.00 11.03 1.049 25.29 E 2.00 0.433 SCHED 40 WET STEEL 120 9.39 0 3.00 1.036 4 8.00 30.30 25.29 9.99 1.00 25.29 0.20094 1.00 0.603 104 0.00 29.30 0.00 11.03 1.049 25.29 E 2.00 0.433 SCHED 40 WET STEEL 120 9.39 0 3.00 1.036 5 8.00 30.30 25.31 10.01 1.00 25.31 0.20121 1.00 0.604 105 0.00 29.30 0.00 11.04 1.049 25.31 E 2.00 0.433 SCHED 40 WET STEEL 120 9.39 0 3.00 1.037 6 8.00 30.30 24.68 9.52 1.00 24.68 0.19208 1.00 0.576 106 0.00 29.30 0.00 10.53 1.049 24.68 E 2.00 0.433 SCHED 40 WET STEEL 120 9.16 0 3.00 1.009 7 8.00 30.30 25.50 10.16 1.00 25.50 0.20403 1.00 0.612 107 0.00 29.30 0.00 11.20 1.049 25.50 E 2.00 0.433 SCHED 40 WET STEEL 120 9.47 0 3.00 1.045 8 8.00 30.30 25.40 10.08 1.00 25.40 0.20258 1.00 0.608 108 0.00 29.30 0.00 11.12 1.049 25.40 E 2.00 0.433 SCHED 40 WET STEEL 120 9.43 0 3.00 1.041 9 8.00 30.30 24.20 9.15 1.00 24.20 0.18526 1.00 0.556 109 0.00 29.30 0.00 10.14 1.049 24.20 E 2.00 0.433 SCHED 40 WET STEEL 120 8.98 0 3.00 0.989 10 8.00 30.30 25.30 10.00 1.00 25.30 0.20114 1.00 0.603 110 0.00 29.30 0.00 11.04 1.049 25.30 E 2.00 0.433 SCHED 40 WET STEEL 120 9.39 0 3.00 1.036 11 8.00 30.30 24.17 9.13 1.00 24.17 0.18487 1.00 0.555 111 0.00 29.30 0.00 10.12 1.049 24.17 E 2.00 0.433 SCHED 40 WET STEEL 120 8.97 0 3.00 0.988 12 8.00 30.30 25.31 10.01 1.00 25.31 0.20124 1.00 0.604 112 0.00 29.30 0.00 11.05 1.049 25.31 E 2.00 0.433 SCHED 40 WET STEEL 120 9.40 0 3.00 1.037 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self StStargleda9A1t4Ml8,2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calcu l a ti o n Program Elite Et Software Inc.Phillip Roe p Hydraulic Calculation Burlington,KY 41005 P age 4 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor (feet) Discharge Pressure Inside Dia. PE-(psi) Node (K) ( ) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 13 8.00 30.30 25.38 10.06 1.00 25.38 0.20225 1.00 0.607 113 0.00 29.30 0.00 11.10 1.049 25.38 E 2.00 0.433 SCHED 40 WET STEEL 120 9.42 0 3.00 1.040 14 8.00 30.30 24.42 9.32 1.00 24.42 0.18836 1.00 0.565 114 0.00 29.30 0.00 10.32 1.049 24.42 E 2.00 0.433 SCHED 40 WET STEEL 120 9.07 0 3.00 0.998 101 0.00 29.30 0.00 11.10 1.00 0.00 0.20220 1.00 1.213 115 0.00 29.30 0.00 12.31 1.049 25.37 T 5.00 0.000 SCHED 40 WET STEEL 120 9.42 0 6.00 1.213 115 0.00 29.30 0.00 12.31 2.50 0.00 0.00859 1.20 0.045 116 0.00 29.30 0.00 12.27 2.635 51.99 F 4.00 0.000 SCHED 10 WET STEEL 120 3.06 0 5.20 0.045 102 0.00 29.30 0.00 10.45 1.00 0.00 0.19082 4.50 1.813 116 0.00 29.30 0.00 12.27 1.049 24.59 T 5.00 0.000 SCHED 40 WET STEEL 120 9.13 0 9.50 1.813 116 0.00 29.30 0.00 12.27 2.50 0.00 0.00263 8.90 0.034 117 0.00 29.30 0.00 12.23 2.635 27.40 F 4.00 0.000 SCHED 10 WET STEEL 120 1.61 0 12.90 0.034 103 0.00 29.30 0.00 11.03 1.00 0.00 0.20094 1.00 1.206 117 0.00 29.30 0.00 12.23 1.049 25.29 T 5.00 0.000 SCHED 40 WET STEEL 120 9.39 0 6.00 1.206 117 0.00 29.30 0.00 12.23 2.50 2.11 0.00002 5.20 0.000 118 0.00 29.30 0.00 12.23 2.635 2.11 F 4.00 0.000 SCHED 10 WET STEEL 120 0.12 0 9.20 0.000 104 0.00 29.30 0.00 11.03 1.00 0.00 0.20094 1.00 1.206 118 0.00 29.30 0.00 12.23 1.049 25.29 T 5.00 0.000 SCHED 40 WET STEEL 120 9.39 0 6.00 1.206 105 0.00 29.30 0.00 11.04 1.00 0.00 0.20121 1.00 1.207 119 0.00 29.30 0.00 12.25 1.049 25.31 T 5.00 0.000 SCHED 40 WET STEEL 120 9.39 0 6.00 1.207 118 0.00 29.30 0.00 12.23 2.50 23.18 0.00193 4.75 0.017 119 0.00 29.30 0.00 12.25 2.635 23.18 F 4.00 0.000 SCHED 10 WET STEEL 120 1.36 0 8.75 0.017 106 0.00 29.30 0.00 10.53 1.00 0.00 0.19208 4.50 1.825 120 0.00 29.30 0.00 12.35 1.049 24.68 T 5.00 0.000 SCHED 40 WET STEEL 120 9.16 0 9.50 1.825 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®-4eda9glljl1iW8,2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program __--o- Deyelo Imo, Elite Software Development Inc. Phillip Roe Ell Hydraulic Calculation Burlington,KY 41005 ii'`"'� Page 5{ Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len. Elevation Q (gpm) (psi/ft) Fit-Len. PF-(psi) End. KFactor (feet) Discharge Pressure Inside Dia. PE-(psi) Node (K) ( ) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) (p ) 119 0.00 29.30 0.00 12.25 2.50 0.00 0.00755 9.25 0.100 ' 120 0.00 29.30 0.00 12.35 2.635 48.49 F 4.00 0.000 SCHED 10 WET STEEL 120 2.85 0 13.25 0.100 107 0.00 29.30 0.00 11.20 1.00 0.00 0.20403 1.00 1.224 121 0.00 29.30 0.00 12.43 1.049 25.50 T 5.00 0.000 SCHED 40 WET STEEL 120 9.47 0 6.00 1.224 120 0.00 29.30 0.00 12.35 2.50 0.00 0.01617 0.75 0.077 121 0.00 29.30 0.00 12.43 2.635 73.16 F 4.00 0.000 SCHED 10 WET STEEL 120 4.30 0 4.75 0.077 108 0.00 29.30 0.00 11.12 1.00 0.00 0.20258 1.00 1.215 122 0.00 29.30 0.00 12.34 1.049 25.40 T 5.00 0.000 SCHED 40 WET STEEL 120 9.43 0 6.00 1.215 122 0.00 29.30 0.00 12.34 2.50 0.00 0.00969 2.75 0.065 123 0.00 29.30 0.00 12.27 2.635 55.46 F 4.00 0.000 SCHED 10 WET STEEL 120 3.26 0 6.75 0.065 109 0.00 29.30 0.00 10.14 1.00 0.00 0.18526 6.50 2.130 123 0.00 29.30 0.00 12.27 1.049 24.20 T 5.00 0.000 SCHED 40 WET STEEL 120 8.98 0 11.50 2.130 123 0.00 29.30 0.00 12.27 2.50 0.00 0.00335 3.50 0.025 124 0.00 29.30 0.00 12.25 2.635 31.26 F 4.00 0.000 SCHED 10 WET STEEL 120 1.84 0 7.50 0.025 110 0.00 29.30 0.00 11.04 1.00 0.00 0.20114 1.00 1.207 124 0.00 29.30 0.00 12.25 1.049 25.30 T 5.00 0.000 SCHED 40 WET STEEL 120 9.39 0 6.00 1.207 124 0.00 29.30 0.00 12.25 2.50 5.96 0.00016 5.50 0.001 125 0.00 29.30 0.00 12.24 2.635 5.96 F 4.00 0.000 SCHED 10 WET STEEL 120 0.35 0 9.50 0.001 111 0.00 29.30 0.00 10.12 1.00 0.00 0.18487 6.50 2.126 125 0.00 29.30 0.00 12.24 1.049 24.17 T 5.00 0.000 SCHED 40 WET STEEL 120 8.97 0 11.50 2.126 112 0.00 29.30 0.00 11.05 1.00 0.00 0.20124 1.00 1.207 126 0.00 29.30 0.00 12.25 1.049 25.31 T 5.00 0.000 SCHED 40 WET STEEL 120 9.40 0 6.00 1.207 125 0.00 29.30 0.00 12.24 2.50 18.21 0.00123 2.50 0.008 126 0.00 29.30 0.00 12.25 2.635 18.21 F 4.00 0.000 SCHED 10 WET STEEL 120 1.07 0 6.50 0.008 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®algleda9AlIlfivr8,2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program - rogram � Elite Software Development,Inc. Phillip Roe ?�'S Hydraulic Calculation _Burlington,KY 41005 orwil Page 6 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) q (gpm) F. Lift Pipe-Len. Beg. Nodal Spk/Hose Residual Nom. Dia. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot Len. PT-(psi) (fps) Type-Grp (ft) 113 0.00 29.30 0.00 11.10 1.00 0.00 0.20225 1.00 1.213 127 0.00 29.30 0.00 12.32 1.049 25.38 T 5.00 0.000 SCHED 40 WET STEEL 120 9.42 0 6.00 1.213 126 0.00 29.30 0.00 12.25 2.50 0.00 0.00618 6.20 0.063 127 0.00 29.30 0.00 12.32 2.635 43.52 F 4.00 0.000 SCHED 10 WET STEEL 120 2.56 0 10.20 0.063 114 0.00 29.30 0.00 10.32 1.00 0.00 0.18836 6.50 2.166 128 0.00 29.30 0.00 12.48 1.049 24.42 T 5.00 0.000 SCHED 40 WET STEEL 120 9.07 0 11.50 2.166 127 0.00 29.30 0.00 12.32 2.50 0.00 0.01447 7.50 0.166 128 0.00 29.30 0.00 12.48 2.635 68.90 F 4.00 0.000 SCHED 10 WET STEEL 120 4.05 0 11.50 0.166 115 0.00 29.30 0.00 12.31 2.50 0.00 0.01793 39.00 0.986 129 0.00 29.30 0.00 13.30 2.635 77.36 T 16.00 0.000 SCHED 10 WET STEEL 120 4.55 0 55.00 0.986 122 0.00 29.30 0.00 12.34 2.50 0.00 0.01946 37.25 1.036 130 0.00 29.30 0.00 13.37 2.635 80.86 T 16.00 0.000 SCHED 10 WET STEEL 120 4.76 0 53.25 1.036 129 0.00 29.30 0.00 13.30 4.00 0.00 0.00173 17.00 0.074 130 0.00 29.30 0.00 13.37 4.260 77.36 T 26.00 0.000 SCHED 10 WET STEEL 120 1.74 0 43.00 0.074 130 0.00 29.30 0.00 13.37 4.00 0.00 0.00649 14.90 0.266 131 0.00 29.30 0.00 13.64 4.260 158.23 T 26.00 0.000 SCHED 10 WET STEEL 120 3.56 0 40.90 0.266 131 0.00 29.30 0.00 13.64 4.00 134.32 0.00480 20.00 0.221 132 0.00 29.30 0.00 13.86 4.260 134.32 T 26.00 0.000 SCHED 10 WET STEEL 120 3.02 0 46.00 0.221 132 0.00 29.30 0.00 13.86 4.00 118.32 0.00379 20.00 0.174 133 0.00 29.30 0.00 14.03 4.260 118.32 T 26.00 0.000 SCHED 10 WET STEEL 120 2.66 0 46.00 0.174 133 0.00 29.30 0.00 14.03 4.00 108.29 0.00322 20.00 0.148 134 0.00 29.30 0.00 14.18 4.260 108.29 T 26.00 0.000 SCHED 10 WET STEEL 120 2.44 0 46.00 0.148 134 0.00 29.30 0.00 14.18 4.00 102.48 0.00291 20.00 0.134 135 0.00 29.30 0.00 14.31 4.260 102.48 T 26.00 0.000 SCHED 10 WET STEEL 120 2.31 0 46.00 0.134 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St a9AfLtjiv48,2015,9:48 PM 1 I Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Phillip Roe CH Hydraulic Calculation I Burlington,KY 41005 Pa e 7 Fire Sprinkler Output Data rOverali Pipe Output Data cont'd • Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe Len. PF (psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) (feet) Velocity Fittings Tot-Len. Node (K) (gpm) (psi) C-Value (fps) Type Grp (ft) PT-(psi) 135 0.00 29.30 0.00 14.31 4.00 99.03 0.00273 18.75 0.122 136 0.00 29.30 0.00 14.44 4.260 99.03 T 26.00 0.000 SCHED 10 WET STEEL 120 2.23 0 44.75 0.122 136 0.00 29.30 0.00 14.44 4.00 95.25 0.00254 13.60 0.101 137 0.00 29.30 0.00 14.54 4.260 95.25 T 26.00 0.000 SCHED 10 WET STEEL 120 2.14 0 39.60 0.101 137 0.00 29.30 0.00 14.54 4.00 88.57 0.00222 20.00 0.102 138 0.00 29.30 0.00 14.64 4.260 88.57 T 26.00 0.000 SCHED 10 WET STEEL 120 1.99 0 46.00 0.102 138 0.00 29.30 0.00 14.64 4.00 77.60 0.00174 20.00 0.080 139 0.00 29.30 0.00 14.72 4.260 77.60 T 26.00 0.000 SCHED 10 WET STEEL 120 1.75 0 46.00 0.080 139 0.00 29.30 0.00 14.72 4.00 60.89 0.00111 20.00 0.051 140 0.00 29.30 0.00 14.77 4.260 60.89 T 26.00 0.000 SCHED 10 WET STEEL 120 1.37 0 46.00 0.051 140 0.00 29.30 0.00 14.77 4.00 39.50 0.00050 14.70 0.020 141 0.00 29.30 0.00 14.79 4.260 39.50 T 26.00 0.000 SCHED 10 WET STEEL 120 0.89 0 40.70 0.020 141 0.00 29.30 0.00 14.79 4.00 19.57 0.00014 9.10 0.005 142 0.00 29.30 0.00 14.80 4.260 19.57 T 26.00 0.000 SCHED 10 WET STEEL 120 0.44 0 35:10 0.005 121 0.00 29.30 0.00 12.43 2.50 0.00 0.02811 32.33 1.359 143 0.00 29.30 0.00 13.79 2.635 98.66 T 16.00 0.000 SCHED 10 WET STEEL 120 5.80 0 48.33 1.359 128 0.00 29.30 0.00 12.48 2.50 0.00 0.02536 36.25 1.325 144 0.00 29.30 0.00 13.81 2.635 93.32 T 16.00 0.000 SCHED 10 WET STEEL 120 5.49 0 52.25 1.325 143 0.00 29.30 0.00 13.79 6.00 0.00 0.00039 17.00 0.021 144 0.00 29.30 0.00 13.81 6.357 98.66 T 38.00 0.000 SCHED 10 WET STEEL 120 1.00 0 55.00 0.021 131 0.00 29.30 0.00 13.64 2.50 23.90 0.00204 101.10 0.239 145 0.00 29.30 0.00 13.88 2.635 23.90 T 16.00 0.000 SCHED 10 WET STEEL 120 1.41 0 117.10 0.239 144 0.00 29.30 0.00 13.81 6.00 0.00 0.00132 14.90 0.070 145 0.00 29.30 0.00 13.88 6.357 191.98 T 38.00 0.000 SCHED 10 WET STEEL 120 1.94 0 52.90 0.070 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®akqleda9AlLlfiv48,2015, 9:48 PM p Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Develo ment,Inc. Phillip Roe Hydraulic Calculation Burlington,KY 41005 Page 8 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) (feet) Velocity Fittings Tot-Len. Node (K) (gpm) (psi) C-Value (fps) Type Grp (ft) PT-(psi) 132 0.00 29.30 0.00 13.86 2.50 16.00 0.00097 101.10 0.114 146 0.00 29.30 0.00 13.97 2.635 16.00 T 16.00 0.000 SCHED 10 WET STEEL 120 0.94 0 117.10 0.114 145 0.00 29.30 0.00 13.88 6.00 0.00 0.00164 20.00 0.095 146 0.00 29.30 0.00 13.97 6.357 215.89 T 38.00 0.000 SCHED 10 WET STEEL 120 2.18 0 58.00 0.095 133 0.00 29.30 0.00 14.03 2.50 10.03 0.00041 101.10 0.048 147 0.00 29.30 0.00 14.08 2.635 10.03 T 16.00 0.000 SCHED 10 WET STEEL 120 0.59 0 117.10 0.048 146 0.00 29.30 0.00 13.97 6.00 0.00 0.00187 20.00 0.109 147 0.00 29.30 0.00 14.08 6.357 231.88 T 38.00 0.000 SCHED 10 WET STEEL 120 2.34 0 58.00 0.109 134 0.00 29.30 0.00 14.18 2.50 5.81 0.00015 101.10 0.017 148 0.00 29.30 0.00 14.20 2.635 5.81 T 16.00 0.000 SCHED 10 WET STEEL 120 0.34 0 117.10 0.017 147 0.00 29.30 0.00 14.08 6.00 0.00 0.00203 20.00 0.118 148 0.00 29.30 0.00 14.20 6.357 241.92 T 38.00 0.000 SCHED 10 WET STEEL 120 2.45 0 58.00 0.118 135 0.00 29.30 0.00 14.31 2.50 3.45 0.00006 101.10 0.007 149 0.00 29.30 0.00 14.32 2.635 3.45 T 16.00 0.000 SCHED 10 WET STEEL 120 0.20 0 117.10 0.007 148 0.00 29.30 0.00 14.20 6.00 0.00 0.00212 20.00 0.123 149 0.00 29.30 0.00 14.32 6.357 247.73 T 38.00 0.000 SCHED 10 WET STEEL 120 2.50 0 58.00 0.123 136 0.00 29.30 0.00 14.44 2.50 3.78 0.00007 101.10 0.008 150 0.00 29.30 0.00 14.44 2.635 3.78 T 16.00 0.000 SCHED 10 WET STEEL 120 0.22 0 117.10 0.008 149 0.00 29.30 0.00 14.32 6.00 0.00 0.00217 18.75 0.123 150 0.00 29.30 0.00 14.44 6.357 251.18 T 38.00 0.000 SCHED 10 WET STEEL 120 2.54 0 56.75 0.123 137 0.00 29.30 0.00 14.54 2.50 6.69 0.00019 101.10 0.023 151 0.00 29.30 0.00 14.56 2.635 6.69 T 16.00 0.000 SCHED 10 WET STEEL 120 0.39 0 117.10 0.023 150 0.00 29.30 0.00 14.44 6.00 0.00 0.00223 13.60 0.115 151 0.00 29.30 0.00 14.56 6.357 254.96 T 38.00 0.000 SCHED 10 WET STEEL 120 2.58 0 51.60 0.115 1 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self StSaltiedai9Af1448,2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Phillip Roe 1 Hydraulic Calculation i Burlington,KY 41005 - -- Page 9 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot Len. PT-(psi) (fps) Type-Grp (ft) 138 0.00 29.30 0.00 14.64 2.50 10.96 0.00048 101.10 0.056 152 0.00 29.30 0.00 14.70 2.635 10.96 T 16.00 0.000 SCHED 10 WET STEEL 120 0.64 0 117.10 0.056 151 0.00 29.30 0.00 14.56 6.00 0.00 0.00234 20.00 0.136 152 0.00 29.30 0.00 14.70 6.357 261.64 T 38.00 0.000 SCHED 10 WET STEEL 120 2.64 0 58.00 0.136 139 0.00 29.30 0.00 14.72 2.50 16.71 0.00105 101.10 0.123 153 0.00 29.30 0.00 14.84 2.635 16.71 T 16.00 0.000 SCHED 10 WET STEEL 120 0.98 0 117.10 0.123 152 0.00 29.30 0.00 14.70 6.00 0.00 0.00253 20.00 0.147 153 0.00 29.30 0.00 14.84 6.357 272.60 T 38.00 0.000 SCHED 10 WET STEEL 120 2.76 0 58.00 0.147 142 0.00 29.30 0.00 14.80 2.50 0.00 0.00141 101.10 0.165 154 0.00 29.30 0.00 14.96 2.635 19.57 T 16.00 0.000 SCHED 10 WET STEEL 120 1.15 0 117.10 0.165 141 0.00 29.30 0.00 14.79 2.50 19.93 0.00146 101.10 0.171 155 0.00 29.30 0.00 14.96 2.635 19.93 T 16.00 0.000 SCHED 10 WET STEEL 120 1.17 0 117.10 0.171 154 0.00 29.30 0.00 14.96 6.00 0.00 0.00002 9.10 0.001 155 0.00 29.30 0.00 14.96 6.357 19.57 T 38.00 0.000 SCHED 10 WET STEEL 120 0.20 0 47.10 0.001 140 0.00 29.30 0.00 14.77 2.50 21.40 0.00166 101.10 0.195 156 0.00 29.30 0.00 14.97 2.635 21.40 T 16.00 0.000 SCHED 10 WET STEEL 120 1.26 0 117.10 0.195 155 0.00 29.30 0.00 14.96 6.00 0.00 0.00007 14.70 0.004 156 0.00 29.30 0.00 14.97 6.357 39.50 T 38.00 0.000 SCHED 10 WET STEEL 120 0.40 0 52.70 0.004 153 0.00 29.30 0.00 14.84 6.00 0.00 0.00282 8.20 0.130 157 0.00 29.30 0.00 14.97 6.357 289.31 T 38.00 0.000 SCHED 10 WET STEEL 120 2.92 0 46.20 0.130 156 0.00 29.30 0.00 14.97 6.00 0.00 0.00016 11.90 0.008 157 0.00 29.30 0.00 14.97 6.357 60.89 T 38.00 0.000 SCHED 10 WET STEEL 120 0.62 0 49.90 0.008 157 0.00 29.30 0.00 14.97 6.00 0.00 0.00402 2.33 0.082 158 0.00 29.30 0.00 15.05 6.357 350.21 E 18.00 0.000 SCHED 10 WET STEEL 120 3.54 0 20.33 0.082 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self Staalweda9A/tilfiiu48, 2015,9:48 PM - ----- ----------- Fire-Fire Sprinkler Hydraulics Calculation Program ils-�� Elite Software Development,Inc I Phillip Roe FOR Hydraulic Calculation 1 Burlington,KY 41005 w'°"iii Page 10 Fire Sprinkler Output Data 1 Overall Pipe Output Data (cont'd) -. Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F L./ft Pipe Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. (p PE si) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot Len. PT-(psi) (fps) Type-Grp (ft) (p ) 158 0.00 29.30 0.00 15.05 6.00 0.00 0.00402 20.00 0.153 159 0.00 9.30 0.00 23.87 6.357 350.21 E 18.00 8.660 SCHED 10 WET STEEL 120 3.54 0 38.00 8.813 159 0.00 9.30 0.00 23.87 6.00 0.00 0.00402 8.50 0.179 160 0.00 9.30 0.00 24.05 6.357 350.21 2E 36.00 0.000 SCHED 10 WET STEEL 120 3.54 0 44.50 0.179 160 0.00 9.30 0.00 24.05 6.00 0.00 0.00402 11.30 0.813 161 0.00 1.00 0.00 28.45 6.357 350.21 F2T2B2C 191.00 3.594 SCHED 10 WET STEEL 120 3.54 0 202.30 4.407 161 0.00 1.00 0.00 28.45 6.00 0.00 0.00438 17.00 0.238 162 0.00 -4.00 0.00 30.86 5.890 350.21 2E 37.20 2.165 CAST IRON, CEMENT 140 4.12 0 54.20 2.403 162 0.00 -4.00 0.00 30.86 6.00 0.00 0.00354 68.00 0.465 163 0.00 -4.00 0.00 31.32 5.993 350.21 3E 63.30 0.000 PVC, CLASS 200 150 3.98 0 131.30 0.465 163 0.00 -4.00 0.00 31.32 6.00 0.00 0.00438 8.50 0.119 164 0.00 2.00 0.00 28.84 5.890 350.21 E 18.60 -2.598 CAST IRON, CEMENT 140 4.12 0 27.10 -2.479 164 Backflo 2.00 28.84 350.68 Prey 165 3.00 psi 2.00 31.85 165 0.00 2.00 0.00 31.85 6.00 0.00 0.00438 8.50 0.200 166 0.00 -4.00 0.00 34.65 5.890 350.21 2E 37.20 2.598 CAST IRON, CEMENT 140 4.12 0 45/0 2.798 166 0.00 -4.00 0.00 34.65 6.00 0.00 0.00354 76.00 0.521 167 0.00 0.00 0.00 33.44 5.993 350.21 ETG 70.90 -1.732 PVC, CLASS 200 150 3.98 0 146.90 -1.211 Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®ateda9Alt.Ulf48, 2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program - _ - pme Inc.Phillip Roe 9 r i; Elite Software Development, . Hydraulic Calculation Burlington,KY 41005 *- Pie 11 Fire Sprinkler Output Data I Overall Sprinkler Output Data Flowing Area Group Sprinkler Sprinkler Residual Flowin Flowing Sprinkler Sprinkler Elevation Pressure 9 Density Discharge Node No. Code KFactor(K) (feet) (psi) Area (ft ) (gpm/ft2) (gpm) 1 8.00 30.30 10.06 120.00 0.211 25.37 Sub Totals For Non-Group 120.00 0.211 25.37 2 8.00 30.30 9.45 123.00 0.200 24.59 Sub Totals For Non-Group 123.00 0.200 24.59 3 8.00 30.30 9.99 120.00 0.211 25.29 Sub Totals For Non-Group 120.00 0.211 25.29 4 8.00 30.30 9.99 115.00 0.220 25.29 Sub Totals For Non-Group 115.00 0.220 25.29 5 8.00 30.30 10.01 120.00 0.211 25.31 Sub Totals For Non-Group 120.00 0.211 25.31 6 8.00 30.30 9.52 115.00 0.215 24.68 Sub Totals For Non-Group 115.00 0.215 24.68 7 8.00 30.30 10.16 120.00 0.212 25.50 Sub Totals For Non-Group 120.00 0.212 25.50 8 8.00 30.30 10.08 100.00 0.254 25.40 Sub Totals For Non-Group 100.00 0.254 25.40 9 8.00 30.30 9.15 45.00 0.538 24.20 Sub Totals For Non-Group 45.00 0.538 24.20 10 8.00 30.30 10.00 80.00 0.316 25.30 Sub Totals For Non-Group 80.00 0.316 25.30 11 8.00 30.30 9.13 54.00 0.448 24.17 Sub Totals For Non-Group 54.00 0.448 24.17 12 8.00 30.30 10.01 80.00 0.316 25.31 Sub Totals For Non-Group 80.00 0.316 25.31 13 8.00 30.30 10.06 83.00 0.306 25.38 Sub Totals For Non-Group 83.00 0.306 25.38 14 8.00 30.30 9.32 45.00 0.543 24.42 Sub Totals For Non-Group 45.00 0.543 24.42 1 Totals For All Groups 1320.00 0.265 350.21 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®apeda9AJ1448,2015, 9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Phillip Roe Hydraulic Calculation Burlington,KY 41005 ' Page 12 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node x HMD Sprinkler Node Number: 11 HMD Actual Residual Pressure: 9.13 psi HMD Actual GPM: 24.17 gpm Sprinkler Summary Sprinkler System Type: Wet Specified Area Of Application: 923.00 ft2 Minimum Desired Density: 0.200 gpm/ft2 Application Average Density: 0.379 gpm/ft2 Application Average Area Per Sprinkler: 65.93 ft2 Sprinkler Flow: 350.21 gpm Average Sprinkler Flow: 25.01 gpm OrleriOcity And Imbalance Summary___ Maximum Flow Velocity ( In Pipe 107- 121 ) 9.47 ft/sec Maximum Velocity Pressure( In Pipe 107- 121 ) 0.60 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0076 psi Actual Average Nodal Pressure Imbalance: 0.0003 psi Actual Maximum Nodal Flow Imbalance: 0.4770 gpm Actual Average Nodal Flow Imbalance: 0.0118 gpm Overall Network Summary Number Of Unique Pipe Sections: 93 Number Of Flowing Sprinklers: 14 Pipe System Water Volume: 1277.07 gal Sprinkler Flow: 350.21 gpm Non-Sprinkler Flow: 0.00 gpm Demand Flow Excluding Exterior Hose Flow: 350.21 gpm Exterior Hose Flow: 250.00 gpm Minimum Required Residual Pressure At System Inflow 33.44 psi Node: Demand Flow At System Inflow Node: 600.21 gpm C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®apyeda9A114 48,2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Phillip Roe ? Hydraulic Calculation Burlin ton,KY 41005 Page 13 j Fire Sprinkler Output Data Hydraulic Supply/Demand Graph 100 - 90 80 N 70 Q 60 5 50 0 a_ 40 30 30 20 10 0 0 2 4 6 8 10 12 14 16 18 20 Flowrate(x1 00) gpm Supply Curve Data Static Pressure: 50 psi Test Residual Pressure: 30 psi Test Flow Rate: 1145 gpm Demand Curve Data Calculated Residual Pressure: 33.44 psi Calculated Flow Rate: 600.21 gpm Exterior Hose Flow: 250.00 gpm Excess Available Residual Pressure At Calculated Flow: 10.51 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 16.12 psi C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®aipeda9Afllfiv48,2015,9:48 PM f Page 1 of 4 N1KING® MICROFAST® QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION The Viking Microfast®Quick Response Upright Sprinkler VK350 is a small, ther- mosensitive, glass-bulb spray sprinkler available in several different finishes, temperature ratings, and K-Factors to meet design requirements. The special 1-f Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) ! ` 11' coatings can be used in decorative applications where colors are desired. In ad- dition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval I Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion « 1: resistant.) - , 2. LISTINGS AND APPROVALS c 01. us cULus Listed: Category VNIV FM Approved: Class Series 2000 vds VdS Approved: Certificates G414017 and G414018 ay- LPCB Approved CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0786-CPD-40278 CE NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. • 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP, 3/4" NPT, 20 mm BSP Nominal K-Factor: 8.0 U.S. (115.2 metric—) Glass-bulb fluid temperature rated to-65 °F (-55 °C) Viking Technical Data may be found on Overall Length: 2-5/16" (59 mm) The Viking Corporation's Web site at *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi(0.5 bar). http://www.vikinclude aimore r. The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). The Web site may include a more recent Material Standards: edition of this Technical Data Page. Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers.. Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast®Quick Response Upright Sprinkler VK350 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, and Black PTFE = N, ENT=JN Temperature Suffix(°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK350 with a 1/2"thread, Brass finish and a 155 °F/68 °C temperature rating = Part No 18259AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Form No. F_033014 Rev 14.2 (Added 06665B, 14817, and 06764B) Page 2 of 4 NIKING OD TECHNICAL DATA MICROFAS-P QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray to extinguish or control the fire. 9 pip cap and p y pattern 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast°Quick Response Upright Sprinkler VK350 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. =:TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES ;''Sprinkler Temperature Sprinkler Nominal Classification Ter •erature Ratin•' CMaximum Ambient Ordinary eilin• Temperature2 Bulb Color 135°F(57°C) 100'F(38°C) Ordinary 155°F(68°C) Orange Intermediate 100°F(38°C) Red 175°F(79°C) 150°F(65°C) Intermediate 200°F(93°C) G High 150°F(65°C) Green 286°F(141 °C) 225°F(107°C) Sprinkler Finishes:Brass,Chrome,White Polyester, Black Polyester, Black PTFE,and ENT Blue Corrosion-Resistant Coatings':White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135°F(57°C) 'The sprinkler temperature rating is stamped on the deflector. Footnotes 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester,ENT,and PTFE coatings. For ENT coated automatic sprinklers,the waterway is coated. Protective Sprinkler Cap--.--„___ i ■ i • Wrench Flat ---___________i: il,. s.ti r, r:1 rA ` ^ i 7 4,' 'F' td %, kis.1.( VlM1 r w , Figure 1: Form No. F_033014 Rev 14.2 Standard Sprinkler Wrench 10896W/B 1 ' I ! 1\, li Page 3 of 4 NG.4, 0 TECHNICAL DATA MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 (UL) Temper --- Microfastn Quick Response —Fteh in .to a KEY Upright Sprinkler VK350 MX a—Escutcheon Of applicable) Maximum 175 PSI (12 bar)WWP Base Part Thread Size Nominal K-Factor Overall Length Number' SIN Listings and APprovals� NPT BSP U.S. metric= Inches mm , (Refer also to Design Criteria.) 18257 VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B2 Al LPCB Bl CE 18278 VK350 20 mm 8.0 115.2 2-5/16 59 Al, B2 Al Al B1' 182599 VK350 1/2" 15 mm 8.0 115.2 Al, B2 Al Al B1' 5.2 2-5/16 59 Al, B2 Al — NOTICE Product Below-Limited Availability(Contact Local Viking Office) 61• 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B2 Al Al B17 06764B9 VK350 1/2" 15 mm 8.0 Al, B2 Al Al 61' 115.2 2-5/16 59 Al, B2 111110111MMIN A18 Approved Temperature Ratings A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) 286°F(141°C) , and Approved Finishes B- 155 °F(68 °C), 175 °F(79°C), 200°F(93°C), and 286 °F(141°C) 1 -Brass, Chrome, White Polyester", and Black Polyester" 2-ENT' 'Base part number is shown.For complete part number,refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10 0. 'This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 'Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. °cULus Listed as corrosion resistant. °Other colors are available on request with the same Listings and Approvals as the standard colors. 'CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. °CE Certified,Standard EN 12259-1,EC-certificate of conformity 0786-CPD-40278. °The 1/2'NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. DESIGN CRITERIA NL (Also refer to Approval Chart 1) The Microfastt Quick Response Upright Sprinkler VK350 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033014 Rev 14.2 . a Page 4 of 4 NIKING. MICROFAST® QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) �L —Temper.:„. • KEY • Microfast5 Quick Response Fic+gin Upright Sprinkler VK350 A1X÷Exuteon(taq;'icaC;e) • Maximum 175 PSI(12 bar)WWP Base Part SIN Thread Size Nominal K-Factor Overall Length a 3 Number' FM Approvals NPT BSP U.S. metric2 Inches mm (Refer also to Design Criteria below.) 18257 VK350 3/4” -- 8.0 115.2 2-5/16 59 - _ 18278 VK350 Al, B2 20 mm 8.0 115.2 2-5/16 59 Al, B2 182595 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al B2 NOTICE.Product Below..Limited Availability(Contact Local Viking Office) 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B2 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B2 06764B5 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, 82 Approved Temperature Ratings Approved Finishes A- 135°F(57°C), 155°F(68°C), 175°F(79 °C), 200°F(93 °C), and 286°F(141°C) 1 - Brass, Chrome, White Polyester', and Black B- 155°F(68°C), 175°F(79°C), 200 °F(93°C), and 286°F(141°C) Polyester' 2-ENT' Footnotes 'Base part number is shown. For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Other colors are available on request with the same Approvals as the standard colors. The 1/2'NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. °FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reouirements; The Microfast Quick Response Upright Sprinkler VK350 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide.For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design,ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033014 Rev 14.2 (Added 06665B, 14817, and 06764B) s Page 1 of 6 • NEKING® MICROFAST® QUICK T "ECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION • The Viking Microfast" Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes �= and temperature ratings to meet design requirements. The special Polyester, Polytetrafluoroethelyne (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM , Global has no approval classification for PTFE and Polyester coatings as corro- ~-) sion resistant.) :���� �► 2. LISTINGS AND APPROVALS p� oa cULus Listed: Category VNIV M FM Approved: Class Series 2000 vdS VdS Approved: Certificates G414009 and G414010 NHS LPCB Approved (E CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 and Design Criteria cULus Listing requirements,and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Viking Technical Data may be found on Specifications: The Viking Corporation's Web site at Minimum Operating Pressure: 7 psi (0.5 bar) http://www.vikinggroupinc.com. Rated to 175 psi (12 bar)water working pressure The Web site may include a more recent Factory tested hydrostatically to 500 psi (34.5 bar) edition of this Technical Data Page. Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to-65°F(-55 °C) Overall Length: 2-1/4"(58 mm) °cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Orelk Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector. Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, Black PTFE = N, and ENT=JN Temperature Suffix: 135 °F (68 °C)=A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F(141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C)temperature rating = Part No. 12979AB Form No. F_033314 Rev 15.2 • Page 2 of 6 2211 MICROFAST QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B(available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B**(available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915(available since 2010) **A'/:"ratchet is required(not available from Viking). "'Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool.Ideal for sprinkler cabinets.Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfase Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Wrench Flat Clip Protective Sprinkler "."'"'"•• Cap -""--"w"..""10 ' Y - Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 Rev 15.2 • Page 3 of 6 MICROFAST QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155°F (68 °C) 100°F (38 °C) Red Intermediate 175 °F(79 °C) 150°F (65 °C) Yellow Intermediate 200 °F(93 °C) 150°F(65 °C) Green High 286 °F(141 °C) 225°F(107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester,PTFE,and ENT coatings. For ENT coated automatic sprinklers,the waterway is coated T7trePt•ile v4; t v. Sprinkler wrench 13655W/B** . • # for recessed pendent j sprinklers **A 1/2" ratchet is required • (not available from Viking) Carefully slide the wrench sideways around ,, the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 Rev 15.2 Page 4 of 6 NIKI MICROFAST QUICK TECHNICAL DATA • RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com f Approval Chart 1 (UL) Temperature KEY The Viking Microfast Quick Response Pendent Sprinkler VK302 A1X 1 • Escutcheon tcheon(J appiicabtb) Maximum 175 PSI(12 Bar)WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN Style K-Factor Length (Refer also to Design Criteria.) Number NPT BSP U.S, metric2 Inches mm cULus' VdS LPCB �(' 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y,D2,C2X Al A1Z,B1Y D1Z,C1Y — D3Z NOTICE-Product Below-Limited Availability(Contact Local Vikkig Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 Al Z,B1Y,D2,C2X — — — — — 18021 VK302 Pendent 1/2" 15 mm_ 5.6 80.6 e 2 1/4 58 A1X,61Y Al MX,B1Y D1X D1X C1Y ,C1Y' — Approved Temperature Ratings Approved Finishes Approved Escutcheons A-135°F(57°C), 155°F(68°C), 175°F 1-Brass,Chrome,White X-Standard surface-mounted escutcheon or the (79°C),200°F(93°C),286°F(141°C) Polyester56,Black Polyes- Viking Micromatic5 Model E-1 Recessed Escutcheon B-135°F(57°C), 155°F(68°C), 175°F ter-5.6 Y-Standard surface-mounted escutcheon or the (79°C),and 200°F(93°C) 2-ENT5 Viking Microfast Model F-1 Adjustable Escutcheon,or recessed with the Viking Micro- C-155°F(68°C), 175°F(79°C),and 3-Chrome matic®Model E-1,E-2,or E-3 Recessed Escutcheon 200°F(93°C) Z-Standard surface-mounted escutcheon or the D-155°F(68°C), 175°F(79°C),200°F Viking Microfasta Model F-1 Adjustable Escutcheon (93°C),286°F(141°C) Footnotes 'Base part number shown.For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Other approvals may be in process. •Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 'CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2001. 6 CE Certified,Standard EN 12259-1,EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. e MED Certified,Standard EN 12259-1,EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Reauirements; The Viking Microfaste Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 15.2 • Page 5 of 6 NIKING MICROFASP' QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) Temperatse KEY The Viking Microfast' Quick Response ,- - FMS, Pendent Sprinkler VK302 A1X• Escutcheon Llapplcabte) • Maximum 175 PSI(12 Bar)WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' Style , Design(Refer also to Criteria. NPT BSP U.S. metric Inches mm ( 9 ) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y,D2X,C2 NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y,D2X,C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 _ A1Z,B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A- 135°F(57°C), 155°F(68°C), 175°F(79°C),200°F Viking MicromatiO Model E-1 Recessed (93°C),286°F(141 °C) Approved Finishes Escutcheon B- 135°F(57°C), 155 °F(68 °C), 175 °F(79°C), and 1-Brass,Chrome,White Polyester°, Y - Standard surface-mounted escutcheon or the 200°F(93°C) and Black Polyester4 Viking Microfast5 Model F-1 Adjustable Escutcheon, C - 155°F(68°C), 175 °F(79 °C), 200 °F (93 °C), 286 2-ENT' or recessed with the Viking Micromatica Model E-1 °F(141 °C) or E-2 Recessed Escutcheon D-155°F(68°C),175°F(79°C),200°F(93°C) Z - Standard surface-mounted escutcheon or the Viking Microfast®Model F-1 Adjustable Escutcheon Footnotes 'Base part number shown.For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing.Other approvals may be in process. °Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The Viking Microfastm Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0).FM Global Loss Prevention Data Sheets contain guidelines relating to,but not limited to: minimum water supply requirements,hydraulic design,ceiling slope and obstructions,minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances,and standards, whenever applicable. Form No. F_033314 Rev 15.2 Page 6 of 6 MICROFASP QUICK TECHNICAL DATA - '` RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com ' M=i Ceiling Opening Size: 1/2" 1:7—=:-.±11.---11 2-5/16" (58.7 mm) minimum (15 mm) 2-1/2" (63.5 mm) maximum NPT 2-1/8" \.. s„ 1- (54 mm 2-1/4" Mi 1-1/2" (57 mm) .cf �I i ( 1 314" 51 mm (3M Min. (44.5 mm) ( Max. ) r Installed with a standard Installed with a Microfast Note:At maximum,adapter is 1/8" surface-mounted Model F-1 Adjustable exposed 1/2"(12.7 mm)from escutcheon Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon ~� Ceiling Opening Size: 2-5-16" (58.7 mm) minimum i. 2-1/2" (63.5 mm) maximum 2-1/8" 2-118" (54 mm) mm)—al ..T. r rw ....._ 1-1/8" 1-1/8" 1-3/4" (28.6 mm) 2"" (28.6 mm) (44.5 mm) ,- /� Min (51 mm) -,— ,;y Min. Max. Max. -w,. .. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 Rev 15.2 Replaces Form No. F_033314 Rev 15.1 (Replaced wrench 16036W/B with 13655W/B) August 14, 2013 RE2321 Sprinkler 43o QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature rat- ings to meet varying design requirements. The special Polyester and PTFE coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. 2. LISTINGS AND APPROVALS ) c ut „ cULus Listed: Category VNIV •� Refer to the Approval Chart on page 43r and Design Criteria on page 43s for cULus Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2009. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread Size: 3/4" (20 mm) NPT Nominal K-Factor: 8.0 U.S. (115.2 metric') "Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: 2-5/8" (66 mm) Covered by the following US Patent Nos: 7,854,269 and 7,712.218 Viking Technical Data may be found on Material Standards: The Viking Corporation's Web site at Sprinkler Frame: Brass UNS-C84400 http:Nwww.vikinggroupinc.com. Deflector: Brass UNS-C23000 or Phosphor Bronze UNS-C51000 The Web site may include a more recent Bulb: Glass, nominal 3 mm diameter edition of this Technical Data Page. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screws: 18-8 Stainless Steel Yoke: Phosphor Bronze UNS-C51000 Ejector Spring: 17-7 Stainless Steel For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated F Polvester Coateri Sorinkl rt. Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Horizontal Sidewall Sprinklers by first adding the appropriate suffix suffix for the temperature rating to the sprinkler base part number. ffix for t prIi"kler finish and then the ap- propriate Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, and Black PTFE=N Temperature Suffix (°F/°C): 135°/57°=A, 155°/68°= B, 175°/79° = D, 200°/93° = E For example, sprinkler VK360 with a Brass finish and a 155°F/68 °C temperature rating = Part No 15591AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No 10896W/B (available since 2000). B. Wrench for recessed sprinklers with protective shields: Part No 13655W/B**(available since 2003) "'A'/2"ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) Form No. F_092508 Replaces page 43o-t, dated February 26, 2010. (Added Patent Nos) Sprinkler 43p 2rIll August 14, 2013 QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the yoke, pip cap, and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Quick Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Wrench Sprinkler Flat Shield III _ 10896 I) Figure 1: Standard Sprinkler Wrench 10896W/B August 14, 2013 Sprinkler 43q NI Kim® QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.o) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Classification Maximum Ambient Temperature Rating' Ceiling Temperature' Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and Black PTFE °C) Green Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location.and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only Note that the spring is exposed on sprinklers with Polyester and PTFE coatings. Sprinkler Wrench Part No. 13655W/B0 must be used with Coated and/or Recessed Sprinkler VK360. (Recessed Sprinkler VK360 is shown.) Fit the wrench over the sprinkler and protective shield as shown. (Note the orientation of Protective the shield in the wrench.) II Sprinkler I Shield II —Ii_ ._.iii_ I i 11P!� � 1 o s. --.-47ii--.4- it_ l I I I Refer to data page QR1-3 for I complete installation instructions and Figure 3 *Note: A 1/2" ratchet for correct Final deflector orientation. is required (not available from Viking). Figure 2: Installation of Coated and/or Recessed Sprinkler VK360 a Sprinkler 43r EIZZal August 14, 2013 QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fa: 698181680: Email: techsvcs @vikingcorp.com Approval Chrt Quick Response Horizontal Sidewall Sprinkler VK360 fi Temperature KEY For Light or Ordinary Hazard Occupancies. A1Xf-Escutcheon(if applicable) Deflector must be located 4"to 12"(102 mm to 305 mm)below the ceiling. Base Part Maximum Thread Size Nominal SIN K-Factor Overall Length Listings and Approvals' Number' Pressure (Refer also to Design Criteria on pg 43s.) NPT BSP U.S. metric' Inches mm cULus' NYC FM 15591 VK360 175 psi 3/4" 20 mm 8.0 115.2 2-5/8 66 A1X See Footnote 5 -- LP-- - Approved Temperature Ratings Approved Escutcheons Approved Finishes X - Installed with standard surface-mounted escutcheons or A-135°F(57 C),155°F(68°C), 175°F 1 - Brass, Chrome, White Polyesters, Black the Viking Microfasr Model F-1 Adjustable Escutcheons, (79°C), and 200°F(93°C) Polyester, and Black PTFE6 or recessed with the Viking Micromatica Model E-1 or E-2 Recessed Escutcheon, or the Model G-1 Recessed Escutcheon Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Other approvals may be in process. °Listed by Underwriters Laboratories Inc.for use in the U.S. and Canada. 5 Meets New York City requirements, effective July 1, 2008. 5cULus Listed as corrosion-resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. Ceiling—/ Note top and bottom of the deflector. The top surface is marked 'TOP'. The sprinkler- MUST be oriented as shown. 4' (100 mm) Keep leading edge of the deflector oriented minimum Parallel to the ceiling. to 12' 1—VKaeo ` FL04 Measure from top of (304.8 mm) TOP deflector to ceiling, maximum I I. Top of deflector ��1\ I75T 79'c JIM) cas Bottom of NZ MY deflector Keep the sprinkler frame arms oriented parallel to the ceiling. Figure 3: Correct Deflector Orientation f August 14, 2013 1E2E3 Sprinkler 43s QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.corn DESIGN CRITERIA (Also refer to the Approval Chart on page 43r.) 1JLus L istina jjaculimilmaili Quick Response Horizontal Sprinkler VK360 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • Locate the deflector 4"to 12"(102 mm to 305 mm)below the ceiling. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft.(1.8 m). • Locate no less than 4"(102 mm)from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. DEFLECTOR POSITION:Install sprinkler VK360 with the leading edge of the deflector and the sprinkler frame arms oriented parallel to the ceiling(see Figure 3).THE TOP SURFACE OF THE DEFLECTOR IS MARKED"TOP".The sprinkler must be oriented as shown in Figure 3. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes,ordinances, and standards, whenever applicable. Wall Opening Size: 2-5/16' (58.7 mm) minimum 2-1/2' (63.5 rim) maximum 2-1/2' 1-15/16' 2-5/8' (63.5 rim) (49 rim) (66 mm) I Minimum al 11 II I_ I I_ 2-1/8' �„ ili� \. �. I m) �I (54 m i 11L-147111..,1 I/ 3/4'� pi (20 mm) Sprinkler VK360 NPT 111 2-1/2' (63.5 rim) Installed with a Maximum standard 1/8' (3.1 rim) Installed with a Microfast surface-mounted escutcheon. Model F-1 Adjustable Escutcheon. Figure 4: Sidewall Sprinkler VK360 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon • Sprinkler 43t ElEIZEI August 14, 2013 QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Wall Opening Size: 2-5/16' (58.7 rim) minimum 2-1/2' (63.5 mm) maximum 1-3/4' 1-1/2' (45 mm) I (38 mm) I Minimum Minimum II�iiIU' 2-1/8' 1111TV -Al ' I•i _ l!j (54 mm) I .I I (54 mm) fi,f'iII I "'•' ---;�Illi.: 1.-i L_____100* 1,,ii._ 2-1/2' NI 2 1/8' (63.5 mm) Maximum (54 rim) Maximurt Installed with a Model E-2 Thread-on Recessed Escutcheon. Installed with a Micromatic Model E-1 Recessed Escutcheon. Figure 5: Sidewall Sprinkler VK360 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Wall Opening: 1/8' 2-5/8' (66 mm) Minimum (3.2 mm) 3-3/4' (95 mm) Maximum Ad aptnble Adjustable ` _II \\\ Adapter Outer Cup Ring le 1111 MA, I .\\\ i q1 11� _.I (66 4' � �1 li� i�� ■ mm) I ftio (102 mm) ti\.'/. iir4 il Depth: 1 , 1-1/16' (27 mm) k_ t-1/16'1 (27 mm) Maximum Recess: 1/2' (12.7 rim) Figure 6: Sprinkler VK360 Dimensions with the Model G-1 Escutcheon Form No. F_092508 Replaces page 43o-t, dated February 26, 2010. (Added Patent Nos) Form No. F_012706 Rev 14.2 Page 1 of 5 FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION Viking Freedoms Residential Pendent Sprinkler VK468 is a small, thermosensitive, glass- -- - -_? bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corro- sion resistant as indicated in the Approval Chart. The orifice design, with a K-Factor of 4.9 /41I�SAO MDKi�II,\ (70.6 metrict),allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteris- tics meet the challenges of residential sprinkler standards. 2. LISTINGS AND APPROVALS e Ous UL Listed(C-UL-US-EU): Category VKKW `■� EU VdS Approved °••�•� •�•" VdS NYC Approved: MEA 89-92-E, Volume 35 UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components(MH48034). Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi(34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metrict) tMetric K-factor measurement shown is in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65°F(-55°C) Overall Length: 2-1/4" (58 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Viking Technical Data may be found on Deflector. Brass UNS-C23000, Phosphor Bronze UNS-C51000, or Brass The Viking Corporation's Web site at UNS-C26000 http://www.vikinggroupinc.com. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Web site may include a more recent Polytetrafluoroethylene(PTFE)Tape edition of this Technical Data Page. Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screw: Brass UNS-C36000 For ENT coated sprinklers: Belleville spring- Exposed. Screw and Piocao - ENT plated. Ordering Information:(Also refer to the current Viking price list.) Sprinkler: Base Part No. 13637 Order Sprinkler VK468 by first adding the appropriate suffix for the sprinkler finish - appropriate suffix for the tempera- ture rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome= F,White Polyester= M-/W, Black Polyester=M-/B, . ^ .-i N Temperature Suffix: 155°F(68°C)= B, 175°F (79°C) = D `'' , For example, sprinkler VK468 with a Brass finish and a 155°F (68°C)temperature rating= *art '0. 3637AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B(available since 2000) B. Wrench for recessed sprinklers: Part No. 13577W/B*(available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool"Part No. 15915(available since 2010.) *A'A"ratchet is required(not available from Viking). "Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: (Added VdS Approval) Form No. F_012706 Rev 14.2 Page 2 of 5 N1KING. FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com A Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature= Ordinary 155 °F(68 °C) 100 F (38 'C) Red Intermediate 175°F(79°C) 150 'F (65 C) Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion Resistant Coatings': ENT Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For ENT coated sprinklers,the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. Wrench Flats Protective ��r. 1�, Protective %l` � 1h∎, 0 ite I L � Sprinkler MIMI Sprinkler Cap Shield _.__.... " III t� 10896 --- . Figure 1: Standard Sprinkler Wrench 10896W/B I. . Form No. F_012706 Rev 14.2 Page 3 of 5 NIKINGR! FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1 Approval Chart Viking VK468, 4.9 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13,13R or 13D 2013 Editions Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water L. Overall Length Part Number' Inches mm U.S. metric= Working Pressure Inches mm 13637 VK468 1/2 J 15 4.9 70.6 175 psi(12 bar) 2-1/4 58 Ordinary Temp Intermediate Temp Listings and Approvals' Max.Coverage Rating (155°F168°C) Rating(175°F179°C) Deflector Minimum Area Installation Spacing Ft.X Ft Flow' Pressure' Flow' Pressure' to Type C-UL- Ft. (m X m) GPM PSI GPM PSI Ceiling US- VdS NYC" NSF° m (Umin) (bar) (Umin) (bar) EU' ( ) 12 X 12 13 7.0 13 7.0 (3.7 X 3.7) (49.2) (0.48) (49.2) (0.48) Standard sur- face-mounted 14 X 14 13 7.0 13 7.0 escutcheons,the (4.3 X 4.3) (49.2) (0.48) (49.2) (0.48) Microfast®Model F-1 Adjustable See See See See 16 X 16 13 7.0 13 7.0 1-1/8 to Escutcheon,or Foot- Foot- Foot Foot- 8 (4.9 X 4.9) (49.2) (0.48) (49.2) (0.48) 2 inch recessed with notes notes note note (2,q 7 and 7 and (2.4) the Micromatio9 10. 10. 7. 7. 18 X 18 17 12.0 17 12.0 Model E-1, (5.5 X 5.5) (64.4) (0.83) (64.4) (0.83) E-2,or E-3 Recessed 20 X 20 20 16.7 20 16.7 Escutcheon (6.1 X 6.1) (75.7) (1.15) (75.7) (1.15) Footnotes ' Part number shown is the base part number. For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. For areas of coverage smaller than shown,use the"Flow"and"Pressure"for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum"Flow"and"Pressure"used. 5 Listed by Underwriter's Laboratories, Inc.for use in the U.S.,Canada,and European Union. 6 Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol. 35. 'Approved Finishes are:Brass,Chrome,White Polyester,and Black Polyester° 8 UL Classified to:NSF/ANSI Standard 61,Drinking Water System Components(MH48034). °Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 10 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. Form No. F_012706 Rev 14.2 Page 4 of 5 VIKING R` FREEDOM'S RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com f-1 1,12----,-.-ii i, ili /IIF?Weti LI TA 0 © lid,' Sprinkler Wrench (P', (AP _.—_._.... 13577W/Bww must be used for Installing Step 1: Carefully slide recessed Sprinkler the wrench sideways i around the deflector t --- - i and protective shield. t / - (Note the orientation of Step 2 Carefully press the shield in the wrench.) the wrench upward and turn slightly to ensure wwA 1/2' ratchet is required engagement with the (not available from Viking). sprinkler wrench flats. Figure 2: Wrench 13577W/B for Recessed Sprinkler Installed with a Microfast Model F-1 1/2' - Adjustable Escutcheon (15 mm) ---,\ y N P T `-- f � �t•� ■ %N� �>i�Ilj>r t 1 I /-ll x` .1'1, I\ 2-1/4' 411111 __1-1/2' I I I I (58 mm) (44.5 mm) � 144' .I � f (38.1 mm) . I ' i 1-1/2' (38.1 mm) l \�� ! _-_.... 2' (50.8 mm) got 1 Minimum - Maximum •.� I 1-1/8' I Installed with a _— (28.7 mm) standard 1/8' (3.1 mm) surface-mounted escutcheon Sprinkler VK468 Figure 3: Sprinkler VK468 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Form No. F012706 Rev 14.2 Page 5 of 5 NIKINGR, FREEDOM' RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Ceiling Opening Size 2-5/16' (58.7 rim) minimum 2-1/2' (63.5 rim) maximum 1-3/4' loot 1 1/8' (28.6 rnrn) �. I�I11�Irl 1 I/8' (28.6 rnrn) (44.5 rnrn) Minimum (50.8 rim) ` Minimum Maximum Maximum i Installed with a Micronatic Installed with a threaded Micrornatic Model E-1 Recessed Escutcheon Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK468 Dimensions with the Model E-1 and E-2 Recessed Escutcheons DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU); When using Viking Residential Pendent Sprinkler VK468 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13:The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage.Q[ • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the"design area"in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers:8 ft.(2.4 m). IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, VdS, and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. (Added VdS Approval) 1, r' 3 . r : Schedule..10 and Sc1idu1 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of Bull Moose Tube's Sch. 10 and Sch. 40 pipes are quality pipe products. Our Schedule 10 and made to ASTfv1 and Schedule 40 are FM Approved and UL Listed.(for U.S. products are typically 5 supplied swith our5protective These and Canada), even though these products do not require separate approvals and listings. Bull Moose coating but can be supplied without the coating so Tube made the decision to have them a they can be hot dip galvanized to meet FM pproved and requirements for use in dry systems In accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing with the zinc coating specifications of ASTM A795 or g as our ASTM A53. other fine pipe products. Schedule 10 Pipe •1 , r, t `� . •!� '.,,e � �7 (' i•>r h .^L l!:P41: rt l'!' S`. X•• 4i• 1.315 4 *, 1 1/4 1.097 1.41 lbs/ft 91 1.660 1.442 1.81 lbs/ft 61 1 1/2 1.900 2 1682 2.09 lbs/ft 2.375 2.157 2 37 2 1/2 2.875 2.635 Ibstft 37 3 .635 3.53 lbs/ft 30 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe �`. ..,,.,jay„;4 -.'`- ;:�Y°r. r .r ,�r.,.. i r + 1 1.315 . .� 1, .� ;8undt�5ie, 7� 1 1/4 1.D49 1.68 lbs/ft 1.660 70 1 1/2 1.380 2.27 lbs/ft 51 1.900 1.610 2.72 lbs/ft 44 2 2.375 2 1/2 2.067 3.66 lbs/ft 2.875 2.468 30 3 3.500 5.80 Ibs/ft 30 4 3.068 7.58 lbs/ft 19 4-.500- 4.260 10.80 lbs/ft 19 For proper operation,all pipe surfaces should be cleaned prior to installation tallat oPREPARATION n In rr to provide a leak-tight seat for the asket, —`be free from Indentations and projections from the end of the pipe to the groove All loose paint,scale,din,chips,grease,and rust must be removed prior to installation. Failure to take-these 9 pipe surfaces should be II instructions for the specific fitting usedrn steps may result in irnprpperIing assembly,causing leakage. Also,check the manufacturer's ell l 6 1819 Clarkson Road =or additional information, \�� '/�rhJ Chesterfield,MO 63017 contact your salesperson c C) uS , 1 ` BULL MOQ TUBE t .NY (800)325-4467 today at(800)325-4467 or Q --, V FAX:(636)537-2645 (636)537-2600 in the USA, �3F/1 _'•titsil n:;1;l+,r.,:_ejail r;e: or call(800)Canada A`�- eocompany 41:* e-mail:s,31_s `tt iiitl;_ r;Cf.;yr col;, call(800)882-4666 AN informs'on co Ie,netl here,n Is accurate as known it the time of pupl!calipn avll Noose Tube reserves Ihp righ APPROVED t 10 change prod�cl 9peor,r:al:ona wMOUI notice end.nlhoul.ntumng oe!iga!ton 't 0.R 4. 1 a i "r. ,n > it .r.+u 1.. . . V srk Hole-Cut System MODEL V-M22 MECHANICAL TEE, GROOVED-END OUTLET The VG5 Model V-M22 mechanical tee provides a fast and easy I T mid-pipe grooved-end branch outlet. The groove dimensions c conform to AWWA C606.UIJFM working pressure is rated 300 I Url psi(20 bar). 4 .\ r, ��:, w { 1 J COL US ® I la LISTED APPROVED nl a A.96 Pip* 1442e OIL Run X Stands O.0� •12-0/60.4 --....._-7.-..-11 _ e B6 x s s r "r""" ^^n^h�_..._ m.wlw "°'' nw,o, wwr■ SI 905 S33 ' X7111 --170 3%15 3500 X 1900 300 1.36 6.19 1. 0 ii X 35 1.74 80 X 50 88.9%60 3 64 903 2 I 6.19 1.70 I/2 X 7 ¶83 _ 3 X 2 _...� 3500 X 2.375 230 502 157.2 1020 M12 X 75 1.d3 100 X 40..... SI -__ 921 667 6.19 1.25 I2 X 3 sat 1143X483 921 667 4X15 4.500X1.900 2.00 t I 1719 4.00 1/2 X 3S ' 191 MO X 50 114 3%60 7 64 6 2.63 ! 719 4.00 _ 12 X 3 1 3 4 X 2 �4500 X 2.375 250 1.00 66.7 1826 1014 M 12 X 7S l 8.93 I00X6! I 1143X73.0 70 2.63 719 4.00 t/2 X3 1.35 101.6 4 X 23 4500 X 2.875 2.73 4.00 66.7 17.19 4 44 • MU X 3S 2.66 100580 114 3 X 88.9 89 -- 104 8 2.63 719 f 18. 1/2 X 3 2.41 4X3 4500X3500 66.7 112.6 It 5.06 M/2X35 41 3.50 1 117 t 2.63 J19 I 3.06 t3S X SO 141.3X60.3 I 61 I V6 X3 233 1207 8fA 223.8 � 106.4 MI6 X 90 2.63 S X 2 5563 X2 375 _ 2.30 4.73 125 X66 1413X730 f'14 1.3.8 1.19 SgX3.1/2 1D 120.7 81.0 t 5_79 S X 2S S 563X 2-875 277.8 ¶13.7 M16 X 90 -2 0s"`- 27S 1.75 KOXfO 1683%607 6a 1302 � 319 `"_ 8.81 444 i 5/1 X3•/2 654 _ 6 X 2 +-f 945 W6.4 M16 X 90 2.93 6.623 X 2375 1 250 lj 5.13_ 1 3.77 I 9.87 4.19 150 X 65 168 3 X 73.0 70 5/1 X 3-1/2 612 I30 2 I 91.5 250.8 I 117.1 MI6 X 90 6X25 6625X2473 273 511 3.27 150X80 I 168 11 88.9 I 89 )77 9 Al t 4 44 5/1 X 3-1/2 7.01 130.2 94.5 6 X 3 I 6.625 53500 1 3S0 s!3 372 981 $19 811390 8.10 ISO X 100 1 168.3 X 114 3 9.87 5.19 5/16 T)- ,05 ` I 114 I 132t 945 250.8 tS1.8 M16 XX 9�0 1,D! 6 X 4 I 6.625 X 4500 l 450 i 5.40 I, ` I 3.72 ) 9.87 I 6.25 5/5 X 3-1/2 I 1.91 I Hole diameters lined are suggested hole saw diameters .\ Trusted above all 1A' rr . I. jri1 V's 1n4LXy fe ... )t•ry�J. \IGS'AI Grooved Fittings MODEL V-901 SHORT RADIUS 90° ELBOW MODEL V-903 SHORT RADIUS TEE • C.i. ca 70,7-3: C �l U5 FM L� '� . t�.r c. 2f.�. LISTED s w APPROVED Mg= Pipe 0.D. V-907 SR G O.D. V-903 9 Elbow 117re1/In ®•ht Tee So rC`E!mm/in) K•s/Lba 60] K•s/Lbs _ 0 7 70 61 �n� :.75 Il 2.75 10 7.5 �76 09 72 2 e75 76 1] 65 76.1 1'00 10 7.00 t 0 09 76 Il 90 - 1 ee9 —e6 •0 7500 1.4 e6 zo w0 1— 102 l.t 1.16 114 l 102 T 17 4"4 125 4.500 l 7 102 1 l a 5 1111011__ .. l 4.00 7.9 150 5361 4 66 5 124 6 165.1 140 77 4.66 1 101 S1 1:0 e6 6 16Q5 140 S f 6.625 5.50 140 66 200 710.1 176 11.0 176 16.0 •6 1 176 165 6.04 24.2 I 6.94 16.1 .._ q, t...{. .... oi\,. 0 (... i ' t 1....k _ V 1 3 ` 11 .„ •Nao]w11401e reth hot dp zinc gllvanszed(whaled topuoneo Trusted above aIJ.TM II 20 KING VG su Grooved Fittings MODEL V-7160 END CAP C @DS ® ,. LISTED APPHUVW Lillik r•1 E 4 I-I/I"" fj• V-71150 End Cap PIP*O.D, mm/In mmNn K9s/LEu 66.3 u 1.900 "73--LOO 0.4 SO I 60.3 - 2 O3 2.375 1.00 0.7 65 73 0 3S 2.5 2976 1.00 0.4 .00 0.9 63 761 '- 0.4 1.00 106.0 zs 11 11 MN 4.250 1.00 2.6 175 141.3 23 S 5.363 1 7 1.00 3.7 ISO 169.3 6 0.623 , 3 0 1.00 6.6 ISO 1651 25 " , 3.0 200 219.1 30 6 6.615 416 11 250 1 111 2730 72 70 10 10.750 Las Is 4 300 123.9 72— 00 12 12730 123 22 0 •Also 1WI131:Ie with h61 dp zinc 9aI armed f ushed(opuona6 Trusted above aU.TM 18 �'i<IN ; � �� rYs.w _444*, f� VGSTM Grooved Fittings MODEL V-7120 TEE MODEL V-7135 CROSS '- ii <t i jy n '•:1677 VGS grooved fittings are cast of ductile iron. ,•. . .NI.? it '- 3 0 U F� !'' 444e LISTED �9•V.)>20 Tar APPROVED Fig V•7133 Cane Fig V-7135 Nomsnel - cross Size 0.1).T V 71:0 mm/ln Tee Cross s mmgn Gots 32 X.1/1.136 125 R7 70 07 E K.. 1.136 '— 1.660 2 75 t.0 40 4113 70 t.9 70 2 2 1900 i73 09 70 II ]O 60.3 62 2.0 275 25 6s 2373 323 29 I 3.23 1.i 2s 73 0 - - 2e75 22 9S 30 65 761 4 e 3.75 ._ vi 6 7 2.3 95 W 3O 3 6e 9 106) — ... 10e 3300 4.25 66 4.25 38 W 7 _—_6e 4 4500 127 us ii 5 1463 �® _ 5.563 150 7663 6 765 6.625 650 220 5 120 150.--H-- 1651 i 763 �O 320 _ 143 200 2ro�" 197 " 6.625 275 5 20. 777s p.7 1. •Also 6w56015 ma he dD ant g61v4nind Tuo6Aed(op9on6U Trusted above aII.TM NI 6 �� 1s �idl.�� G r ' .1. � .t 'h 1 F" vo,„ Grooved Fittings GROOVED ELBOWS MODEL V-7110.90° ELBOW MODEL V-7111 45°ELBOW MODEL V-7112 22-1/2°ELBOW MODEL V-7113 11-1/ ° 4 ELBOW f VGS grooved fittings are cast of ductile iron. C E r ' C :ar •E Fig.7112 Fig.7113 ® 22.1/7 Elbow 11-1/4'Elbow UL US LISTED APPROVED C. - C.E' Fig.7110 Rg•7111 fig 90 Elbow 4S Elbow lb it--t/I/ Elbow Elbow Nominel Slse Ftpe V-7t70 V-7111 nm1/in O.D. 9G Elbow 4S Elbow V-7113 32 /n C-1 K•s/Lbs C-� K. Lbs 11-1/4'Elbow 123 1.660 2 7O °S 45 • .. 40 483 7p 11 1.75 4 OZ p7 °! MIN 04 SO 1.900 175 IS 7S 4S 0.6 2 60J 83 0.9 SI 0.9 4a 1] xJ7s 3 2 o T 4e ea 73.0 2.5 2.875 3.75 93 12 S7 ..t8 138 10 6S 761 2.6 2.25 ', 2SI 1.0 3a I0 9S S7 i0 3/ tO 22 1.50 22 - _ 1.0 - BO 889 1.0 108 20 64 13 n47 3.500 _ 1.26 6J LSO 29 37 1.1 le 08 ! 1x7 2e I 76 10 225 43 I.50 18 _ 4500 5.00 62 '7 x0 !3 .. 123 1413 140 3.0 700 31 2.88 !4 L75 S 83 J S 3J S 363 S 30 110 3 25 --• -'- ISO 7.7 y- '- 168.3 163 ----474-- --.'-'--;:;:;"----" - 6 6.6x5 650 141 e9 SO Si 34 tS0 1651 165 S.7 -•-••�--750 9T 3.12 110 200 75 89 !.- . 79 s O 31 ]1 -- - 200 2191 197 125 2 --' -- _. _ tog 250 8625 7.75 273 42s o0 9e 120 3s 10 273 0 229 24 0 } 121 17.0 5 al ::.o z0 o 12.I 10 750 9 00 52 8 4.75 376 - - "' MODEL V 7110DR DRAIN ELBOW , I Nomin.l swo Apo O.D. •Im9rtda c The Model V-7110DR is a grooved-end ductile iron cast elbow with " / D own/in K N°� an integral 1" NPT or BSP drain. The V-7110DR was primarily .0 Ct tl225 SO 603 8] 17.2 ® 12_• designed for,but not limited to,use on fire protection standpipes. 2 _ 2)7s 3.27 x xs -_ 65 T3 0 9s I 7o 40 ,3 _ 23 2.075 I 3.75 x 73 1.57 65 1 7 e 76.1 93 70 40 13 ea 9 E 108 70 49 20 3.500 4 2 2.75 49) ..1 100 1143 127 I 70 63 70 I1' I 4.VO .M/87.1' !■-_{"_�_r.s 0 2.7 2 48 6.6 ISO I 1631 165 70 90 7.0 C US ISO I 1683 163 70 90 .. 70 LISTED i 1PPROVED --° _6675 6.7■33 114 1s! 200 ^- 219.1 197 l 63 114 - tz7 •Also av41l4be was na dip nttc galvanized rnlsneo 1 8 8625 7.76 3.27 ! 4 49 279 (optional) Trusted above all T^1 JII<IfIi i •1 .... ., . . . . . . .... .. , ..... .-. . . ..-.. -.. .- .• .. .... . . .. . . . . . NGs TM Grooved Couplings 1 MODEL V-7706 REDUCING COUPLING The VGS Model V:7706 reducing coupling allows for direct reduction • piping nun and eliminates the need for a concentric reducer and �.on a The fpedaily designed rubber r•~.•�,�,1' telescoping into Larger pipe gasttet helps prevent small pipe from �¢' 9 p pe during vertical assembly. _'` Caution:The ts: Model V-7706 couplings 't {� �Sv'`« as the end cap may p should not be used with an end cap, . 74,1. P Y be sucked into the pipe when draining the system. lc COUS 11:111111• LISTED APPROVED • :.7.....,1_,,,,,:.!..'„, I 3,., Nominal Piper Max.Workin 4.21 p,p• 9 Max.End /may Preuure '^^I�^ mm/In liar/P51 Load Displacement Per Coupling Per 50 x n 603 x 4213 �� �4L0bs mm/In De-ree P! mrn/m In/ft , • ht /1. Belt Site B 2x15 0_31 �/. n..l. 2.373 x 1.900 350 26.0 e3 117 65x50 1350 0.0.17 3•'02' MIO x SS 0.9 770x60] 071 335 1.60 23x2 2875x2]76 0_71 7/bx235 to 0'OU 1'•30• 22.0 96 48 144 M104S5 MI 761 0 603 026 1.2 3.�a S 67 1s9 3/s®Mill ILO I 102 ne 2.6 _. 1•.21• I6 eo x 30 e19.603 21 -• .. 7 x 1 )300 4 2375 6'� 0_]2 '• — 350 3770 0 013 1••01' Ia.O 116 161 16 60x63 e19x 730 24 021 I 137 M3*75 7x2.5 3.500 x 2973 330 1001 0.7.7 ' 11.0 6.61 189 1/2 x 7 El 60xbf al94761 3]70 O.Oq_-i 2•'01' 116 161 Ie M12x75 24 0 22 1 7 •A 10.91 0_32 137 661 169 V2 x7 ® - ... _. -- 2••04' la O 116 i Ids /e 1004 50 114.3460.3 - L7 24 613 O,La •1 16 4•2 4.500 x 2.]75 330 5360 2'•01' 2t 0 146 191 - IOOx6S 11/34710 0..019 51 M1307f 2.4 24 027 5.75 730 1001 O.4.8 2,05 1/1 x] 5.3 4 423 4500x2875 350 I 5360 1••21' 19.0 116 19e 100465 11434761 0.4.8 52 MII47S 24 . _ 24 1091 — 023 ' 3.75 760 203 - - 21.0—�� 1/2 x 3 5 7 •_ 2•.21• 116 198 Si 100 480 • 1143 4 889 24 - _ _ 11.69 0_49 .. ••1 ♦300 x 3.300 330 5360 0 2•.2/' 21.0 146 19e sI 150.100 165.1.111.] �� 019 Off 5.75 280 20! Mtt47S 2.4 21 21 61 0_61 . t/1 4] )•) 20 0 2•-t1' 202 I 269 52 M16490 1504 b0 1613*1117 '- 0 45 2161 0.6.1 6x/ 6.615x1.500 2••11' 190 2W 275 • ~. 200x150 219 141687 5132 0_0.13 MI6x90 24 533! 023 ale 1097 8,6 1675 s 662] 0 61 150 S/6•]•1R l00 20110 0_025 1.-40' 260 371 37 M20 x 120 7.6 200 x 130 219.1 it I651 21 ®� 018 10 21 13 IS 2 21 3/4 4 4.3/4 16 7 260 314 57 '•�10' 150 M2010 120 76 De8ectkln or angular movemenl IS the maximum value drat a coupling allows undo no Internal Pressure. .. •• •• • 'Also**■lade wish 1101 Op Sine galvanized(Oohed(Oplicnaf Trusted above all.TM 13 NIKING . • - ■ .,'•- -•: ..,,. . • '..„•.... . .. , . . . NG s 1441 Grooved Couplings MODEL V-7705 STANDARD FLEXIBLE COUPLING The VGS Model V-7705 flexible coupling is designed for use In a variety of piping applications of moderate or high pressure services.Working pressure is usually �'' dictated by the wall thickness and rating of the pipe being used.The Model V-7705 couplings feature flexibility that can deal with misalignment, distortion, thermal stress,vibration and noise and also resist seismic tremors. With the use of Model V-7705 couplings you can even design a curved layout. See Typical Applications ' –flexible Couplings on page 25. 1 i Sizes available:1-1/2"_ 8"/40mm_200mm Working Pressure:Up to 500 psi/35 bar e c C 0 US – LISTED APPROVED I I/2'-a- Nomirul Pipe Mex.Working Max.End 1 Slze O.D. mrMn mm/1n Pressure Load Displacement Axial Dimensions _ mm/1n BeNPeI Load ml71/I,, A 0 C Dolt m/In Weight gs ht 40 se.] mm/tn mm/In mm/In g 15 6) 1.6 72 _ mm/In Kgs/Lbs 13 1.900 SOO _ we 46 MIO z 55 0.7 1420 0.0625 50 60.3 3S 9.9 1 6 y 129 191 ]/e x C 55 1.6 2 2.373 SOO 129 IO M102 / 0.1 2210 00621 .63 73A )S 111 16 3.]I 50a leg 30410aSe 9 2.5 2.e1S 300 3240 i 99 112 49 M1oxSS 00 6S 761 35. L___A.0625 14 5 5 t 157 16 eV ]lex2•Ve 20 �- 513 117 40 MIOx55 10 e0 8649 3S 21•4' 169 _ Ib 3 1 3.500 500 4110 00625 4.57 169 Ie 1/2 a 75 13 100 114.3 35 35 4 6 61 ' 52 1/2x) 1 e 4SOO 72 HS 7.76 52 M12x 7S 19 100 1 7950 D.12f 3 n 776 — 123 1413 31 I 41.6 201 1/2x3 41 ]2 172 234 5 5263 ISO 10930 0.125 S2 M16x90 26 ISO 1651 31 66.1 3 2 �•—196— 0 21 2.05 S/e z 3-tr2 Si •_ 260 -- S4 MI6 a 90 31 ISO 1667 31 690 31 — ... _. _ 6 6.625 450 2D0 268 62 MI6*90 3.2 •15500 0.123 1.17 loss 244 200 2191 31 116 9 'T SRI 6 a 90 S 70 e 1 623 430 3i 160 ISO M Ml{x90 � Se 1 26200 0.123 j 10 24 I 13 7e 2 52 5/e a 3-1/2 128 'Also miabk„ilh hot dip zinc galvanized 6nnhed Io00ons9 Trusted above aI1.rM 12 �'11(1 Right Hand Coupling _ /„�nJV Star �/�IVVIL Malleable FirePranuWDi UXIofenvCinternational Z Iron Fittin gs Class 15 0 (Standard] Submittal Sh e APPROVED T' For Listing/Approval w details contact your AnviiStars"'Representative am. . FIGURE 1121 RIGHT HAND COUPLING W Weight Klock NPS/DN la/mm 16s/kg A 1.c 0 06 0.06 /s '11, 0.09 0.09 __ — —.____T_. _ 0 13 013 h IAs 02 — 0.21 0.21 ------77^ �''� 019 031 1 1 As 0 48 019 1/4 1'A, 071 016 1 1 2 7'S i IS 16 21/2 I. ft I( 7 4 7 S 3 .MI 33 31 4 Si MATERIAL SPECIFICATIONS. Anvil Class 150 (standard Weight)Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME 816.3 and Unions conform to ASME 816.39. Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight bonded pattern fittings in this catalog, ALL MOWS&TEES 3/o'(IODNM ond LARGER ARE 100%GAS TESTED ATA sizes I/8 NPS to 6 NPS (6 to 150 DN) inclusive, are included MINIMUM OF t00P$I.lo.9bar! NOTE See the Technical Data section for pressure•lemperalure ratings Sea AnvilSlor Web site for the most current listings and approvals PROJECT INFORMATION: Project: APPROVAL STAGTP: Date: I Phone: Architect/Engineer: I Contractor: i Address: Notes 1: --- —. Notes 2: Anvil Cast&Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe schedule, Rev oa 03.oe4ca4 go to www.anvllstar.com 01 contact your local AnvilStar representative W Z 7,NN01. FIG. 1124 Cap AMA-Star' ---�_.— F.re Predi,ci�r�+ian d Mvr nVaN �.rwt� Malleable Iron Fittings Class 150 (Standard) Submittal Sheet APPROVED •FIGURE 1124 CAP For Listing/Approval derails contact tact your Weight Size AnvtIStarrm Representative If block gal,. NPS/ON lbs./kg /bsJkg 003 0 04 • 0.06 0.06 's4 009 01 0 12 0 1? /1 0? 0.38 0.38 IA I 058 0.61 11/2 —I- 0 73 0 75 2 11 11 2'h 18 18 3 26 28 • 31h 3 2 3 2 4 45 46 S .T. 64 69 6 10 10 •'rA,''/ &sh Id,8&10 ON ore Made in Stele MATERIAL SPECIFICATIONS Anvil Class 150(standard Weight)Malleable Iron Fittings in the "List of Id conform to ASME B16.3 and Unions conform to ASME B16.39 Materials" issued bye the FUnderrwri ears' Laboratories,n c. Anvil standard weight banded pattern fittings in this catalog, Alt EL8Ow58 TEES Ys'110 DN) ond LARGER ARE 100%GAS TESTEDATA sizes I/8 NPS to 6 NPS (6 to 150 DN) inclusive, are included MINIMUM OF 100 PSI.(6.9 bar) NOTE.Set the Technical Data section for pressure.lemperoture ratings See AnvilStor Web site for the moo current Listings and approvals PROJECT INFORMATION: APPROVAL STAMP: Project: Date: Phone: Architect/Engineer: Contractor: Address: Notes 1: --- Notes 2: Anvil Cast 6 Malleable Iron Fittings For the latest UlIULC Listed and FM Approved pressure'attnes.versus pipe schedule, REV 03 03 36-0035 go to www.anvltstar.com or contact your local AnviiStar representative Sz �NV14 • • FiG,• 11058. Reducing Tee 1 Fire Products Div Seta!'" Z;)4NVI4 Malleable Iron Fittings Class 150 (Standard) Submittal Sheet ,� APPROVED ' ""i- For Listing/Approval details contact your i_ AnvilStarn,Representative. 4 -- - FIG.•1105R REDUCING TEE JENIIAgIFYATIMILIMMIIIIng au o 14 .�•, ,„ -„ tit l►:j�, l- �; ^` �� 013 0.11 -�>��� 0.45 0`16 t 0.19 0.7 0.36 h I0.46 0.48 0.19 01 1._.....__' / 0.43 0 41 I MAW 0.21 0.22 I h i 3s ( �, 051 OSI 0 21 0.19 �� 0.38 0.4 ib �� 011 012 A all 0.11 0.46 is ,A. 016 029 1 'A Oil 5 nt I n s I A 0 4 019 In wow 03 031 IT_ 1 n ins 14 061 046 i IA Sil= NI 0.28 0.19 1111111111111 0 9 093 1q I ! 0.21 0.29 .,? 11111 1 r?s 0.3 0 32 I .4 1 A . 1 A 4. 0.43 0.45 -- I T'l Iy 4 14 0 5 j 05r • MATERIAL SPECIFICATIONS Anvil Class 150 (standard Weight) Malleable Iron Fittings in the "list of Inspected Fire Protection Equipment and conform to ASME B 16.3 and Unions conform to ASME B 16.39. Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight banded pattern fittings in this catalog, All ELBOWS A TEES Wh'110DM orsd LARGER ARE IW%GAS TESTED ATA sizes 1/8 NPS to 6 NPS (6 to 150 DN) inclusive, are included mimmuMOF 103P51.16.964 NOTE.See the Technical Doia section for pressure-temperature rulings Set AnvilSiar Web site for dse moss current listings and dos It PROJECT IrlFOR6TATIOr4: Project: APPROVAL STAMP: Date: Phone: Architect/Engineer: Contractor: Address: Notes 1: ,._ —— .`____----- Notes 2: ill Anvil Cast&Malleable Iron Fittings D""E .CF 3 REV Anvil 03 a.06-0030 9 For the latest UUULC Listed and FM Approved pressure ratings,versus pipe schedule, go to www.anvllslar corn or contact your local Af•/rlStar representative �, �NV1L FIG. 1105R Reducing Tee �.. g /���,.S ar- 1�j4.NVi4 Malleable Iron Fittings `wP°°�'�^"°"dana�,M N gs Class 150 (Standard) Submittal Sheet z-.; ,� % rf` I ')OXI V • .4x . 1 J••• i j1 NICIAMMINIIIIWIMMIRmintill FIG. 1105R REDUCING'TEE(caNT.) ;� 1111111111 1r>ttrrrf. 1 1h 069 071 '' � ,er. D ����N� �)� ,,� ,,,, .1 A IA IA Ih 055 h 1!.} 1 Ar 1 Ar O SS ih i I 1 —IV 1 As 0 56 -f' 0 62 �, l,} I c I r I I 1.6 1 _ I j TA I h I h ��� 016 013 - 1 IM I�Ar 0.59 062 131 .S I �� IA 1.3 1 ,A 111111111 NI 0.73 0 75 1 11/2 IR I 44 BO I ���® 0/B 081 L1 i A 14 14 14 055 055 n Inr 1 Ai I I I V i 1 A 1 114 la 0.6 -r 0 63 I'i� I I/i 1 111111111e A I'r I/� I 0.7 011 44 I I ' 1 1 1 n 1 A` �� MI A 1A � 081 081 IA I IA I As ��mai 1 A' 092 091 M _11 I 146 I A4 1111 1.1 IIIII 2 I � �h 1/r Elgin I 2 I 16 16 1 1M 14 1'Al 087 094 1'A I 1 1 1 ~i�+ 1 t ��® 1A 14 144 "IT/, 1 I I1 i I2 19 1.'16 14 0 86 086 2 2'A 1.1 Ell 4 I 1 1 AI ' 1 A I Ai 096 088 rity-�' 1'4 I . 1 2 A 2 t II IA1- 1 076 019 IAA 1 I r2 2n ��Ill 11/4 I I I A� A 0 87 0 92 2 I% 11/2 I 1rAr 1 9 IIIII 1 Al I.I 1 1 2 1111111111 . IA ainen 1 1 I 12 I 1 'A 2 IIII IA IAe 086 089 ,I 4 m_ I Yt A I A 1` 2 A Mill 1As 098 0.98 4' 1111111111111 14 1 1 ! r ©� 1 I At IAA 1 AI I 1 2 1.2 __ 2 2A 2Ar 1 ®� . I d ' 14 i-li "' 1 5 I I -1 4 7 111111111 111111111 VT- 1 18 Anvil Cast&Malleable Iron Fittings For the latest UUULC listed and FM Approved pressure ratings,versus pipe schedule, vA` 2 OF 3 tFV.OJ 03 060031 go to www.anvllstar.corn or contact your local AnvilStar representative (�! FIG. 1105R Reducing Tee ,� jr� = /�M/IL Malleable — ____--___— Fro Products V�.ni/ ^ able Iron Fittings Class 150 (Standard) Submittal Sheet ® g f°z"' At.APPfQVEO Y For Listing/Approval #_ .._�..y_ details contact your XI AnvilStartm Representative j— FIG. 1105R REDUCING TEE (coruT.J _ sr:. I x E © N�pH I N' ON- N' DN ���'+ black ., x ®� 16r ��L,1 ■el' ,' 0 a� �� black 3 4 11611111111111 !6r . saws ''' 1'A 1,5 1 , I o 12 4 1• 2<f 3•y, 8 4 6.B 1 1 I i4 IA 2 18 2 1 • I 4 ?h 31A, I 3 41 3A Iyr 2h �� 2.4 15 I 3 3Ar Ai 3A 11 th 2 ?Ar 15 16 Mil 111 2h IC lih 2 2A 2 t 34 24 2 As 24 2 Ai 3.8 1 2A----1'h 83 1 24 2 Ar 24 la 3.6 mai 2' 2i 18 , 1 um 1A 14 29 3 ?'h NMI Ma Ma Tr'tr�_ 1h 24 3 3 1'.t�;_ 38 1 2 24 2/s — 2�h 41 I 3 3A 1, 1A 3A 61 65 i--------/---- 214 2 —15-----11— 4 8 1'.h 4— 24 2 c 1 A6 3 i IA 111111111111M1 3 41 44 1/r Ell 2 t I1 "Ti 3 114 1°Ae 2A. 2' t 5i III 2h 24 2b 58 INN i ifiami 1 As 3 61 61 Anvil Cast&Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe schedule, PAGE 3 OF, RFV 03.03.060032 go to www.anvilstar.coin or contact your local AnvilStar representative Z� �/IL FIG. 1101.8 Reducing Elbow Star -Z-- Fw•ProrWa4 Ok41,%c,of anvil'Im4mrlionr1 `'V /1M/II.: Malleable Iron Fittings Class 150 (Standard) Submittal Sheet tg FM ....-z--; APPROVED i ---ForI.istin 9/A •.,:. •/Approval r details contact your x AnvilStar"u Representative. �I FIGURE 11O1R REDUCING ELBOW Site x t Weight __ _ black ydy Sire l X I Wright NPS/011 NPS/pN _%m in/mm 76s/kg__l -._� 9 NPS/DX T.---- I -- —in/—m-m—. _. beck _gale ' rs - _ c 0.1 —T•-NPS/-1/ irr/mm !n/mm /0.83 V 44/kg 0.1 i �. 0.11 1 h 0.83 0.8 ti 013 ,ih I- I -,._—_—.1—____1.4—'�—T,e 1-0771— _ 1 14 1 a 1 Il _T 0.15 1-17--1--114; ,4 1 to ( /c � 1 9.19 0 2 �_ 1.? _F_ ! h I��"h��—��2 1 3 - 4< "c 0 21 I 0:: --_i____[___ 1.3 i I+h Ih 2 I.: 11 ! 15 /c 0.16 0.28 1-77—I-7.--C , lr )'b 1— 2 A I S IBM 019 0.3 I i— — — III 1.--17-1T ? 1 n 1.8 1As IA 0.39 18 0.1 —�'T—` 1 At r 14 I 1'AS I�c 1'h ?h 2.3 ?S 011 i 0.42 2 P/u `' 19 i' 2 h i 4 046 0.17 � 1 2/ts ? At 38 39 /' JM 0 S OM 3 1 ?h I c 3 4 4 1 IAi, 06? 0.64 1 3 3 � 79 I'rr + Ih� "� 071 , i , 3 073 , 1 iAi 1.,is 086 09 • MATERIAL SPECIFICATIONS . Anvil Class 150 (standard Weight) Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME B16.3 and Unions conform to ASME B16.39. Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight banded pattern fittings in this catalog, A1IEIBOWS&TEES 3/i 110 ON)and LARGER ARE 100%GAS TESTED AT 4 sizes I/s NPS to 6 NPS (6 to 150 DN) inclusive, are included MINIMUM OF 100 PSI.169 bar) NOTE'See the Technical Dolo f dion for preuure.i mperawre roiing, See Anv,i5,or WM A recr the mns+current bongs s anti C 9 PProvals. - PROJECT INFORMATION: Project: APPROVAL STAMP: Date: Phone: Architect/Engineer: Contractor: —----- Address: Notes 1: _ --- Notes 2: Anvil Cast& Malleable Iron Fittings For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule. PP/oa oa 06 ooa. go to www.anvIlsfar.corn or contact'yrn,r „jai Aeviistar ropreesentattve • �=I�AIVIL, Reducer ilNVStar^ "'g' �.111/IL Malleable Iron Fittings FeePronutl�favnanolA"sA 'K°'yGme g Class 150 (Standard) Submittal Sheet 6 g • • •—�_ _ • -_ FIGURE 1125 REDUCE R APPROVED Siie Wei h! M ,'< Site dS Weight — • T_ For Listing/Approval Wink 'dr. �;t. fa I,__WG 111 '� details contact your NPS/DN NPS DN Zn. no 6S �, r black alt. iii -'�' AnvilStarm Representative. �' n ` N rN �� Ibt. NPS ON MPS ON �'m gt 4 0 07 0.08 0 71 0 8 0.11 0.13 © 13 4 'n I In 1 088 0 9 31q 1'' I n I I 0.17 l h 1 15Ar 4 1.8• I _ 09 091 it 0.11 015 Iii� 3 S I 52 0 9 0.93 ih A 11/ 0.55 016 1,1 19 S 0 I.t © Si S 016 018 r 13 4 ail Iti1 0 ZI 0 25 2 I 6 El 11111 ,/� I r 11 0 23 ai tIffff7j 7y f 0.15 0 76 17 16 t 6 3 h f � 4 4 A 96 91 r 0.16 OIB f I 21 - --1? 6 4 TAT 10 II 4 035 037 0.35 tin I a Stn 'f 2.'• •rOa 1 1.,At 0.33 I n 2 1 r 1 I I h 0 39 0.41 . 2 �I _ _ I 1.S 16 F i'' 0 42 0 44 - -- j 'I j� T'3.2 31 rS ■ O.d 0 63 / -- -ill ® 3 1t/, A 1'As j 0.64 065 3 1-1177-1 3"4i 33 35 1 0.68 0 2 31 34 _Lira 3.3 3/ MATERIAL SPECIFICATIONS Anvil Class 150(standard Weight)Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME 816.3 and Unions conform to ASME 816.39 Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight banded pattern fittings in this catalog, ALL MOWS&TEES'ri(10 ON and URGER'kE1013 GAS TESTED AIA sizes 1/e NPS to 6 NPS )6 to 150 DN) inclusive, ore included A1N1M UM OF IOOPSt.(d96orl NOTE.See the Technical Dolo section for pressure.tem rc r tin s. ---......—_ .. Pe Ne r g Se ee Mv,I54v Web site for Ilse most twrerY h o t ngl and approvals. PROJECT INFORM Project: INFORMATION: _....___ _.._.,.._.._ .�..___�. �.-.. APPROVAL -•.�._-.'.."`"".«..y. STAMP: Date: Phone: Architect/Engineer: Contractor: Address: Notes 1: ------- —__.__._._.._ Notes 2: Anvil Cast& Malleable Iron Fittings i aEV.03 03 06-0033 9 For the latest UL/ULC Listen ann FM Approves pressure ratings,versus pipe schedule, go to www.anvltstar.corn or contact your local AnvllStar representativeZ�/J1VVI(T - FAG. _41105 straight Tee A �-�--� Z'>��N1/II Malleable Iron Fit F+•arst�r~ Fittings Class 150 (Standard) x 0 @ Submittal Sheet• ® 'FIGURE7105'STRAIGHT TELE'` APPRgYEp ---'.:'-'--'- For Listing/Approval details contact your An details Representative. NPS/DN in/mn, �— lbs./kg no 0 09 4 0.1 ---I.., Tom-- " O.IS 016 -----"ThiIT-- 0 36 —0.37 /� :'= 1 OSb t ----.._ I h 0.58 0.4 0.92 11 13 l4, IIMMI 13As 11 - 11111111111111 2A Id A--.. 2h ?.5 1d ��'� -----3-- 2As 4.9 --S E 3r1s —T t . 1 it 34 3A, 90• IC d 3 r 11 12 S 1 4R 19 6 10 S'.i 16 • 30 TO A MATERIAL SPECIFICATIONS Anvil Class 150 (standard Weight) Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME 816.3 and Unions conform to ASME 816.39. Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight banded pattern fittings in this catalog, ALL Et8OWSa TEES Ye1100N)and LARGER ARE 100%GAS TESTEDATA sizes 1/e NPS to 6 NPS (6 to 150 DN) inclusive, are included MwMuMOF 100P9■6.96j NOTE:See the Technical Dole macaw for presrurriemperoiwe rivings, See A+MISior Web re.tar the maw wrens Wing' d n9 an approvals. PROJECT INFORMATION: Project: APPROVAL.STAMP: Date: Phone: Architect/Engineer: Contractor: Address: Notes 1: - - Notes 2: Anvil Cast &Malleable Iron Fittings For the latest ULlULC listed and FM Apprjie:pressure ratings. versus pipe schedule. REV 03 01 060029 go to www.anvllstar.corn or contact your local AnvilStar representative llriANVIIy t • FIG. 1101 so° Elbow i' �!�NtL Malleable Iron 49tar- e on Fittings Class 150 (Standard] nr.T h Submittal Sheet A E �c ® APPROVED For APPROVED ... ... .• _FIGURE 1101 90° ELBOW derailscontactyour • AnvilStar"•Representative. t ``?A°, Site r? A Weigh' Nd._ 114/pR M/mra black palr Illirl 0.06 �� t. 0.11 01? 1 a 'r`—H'T;--i" --611- 1 h .... 017 I'r --;--\--f I�� 0.26 `rl 0.2? I A �' 1 4 `�—= 0.38 0.13 0.63 0.65 15 _ 0.91 O P; —..._-Icy! r s 2 l 2t/' —1 1.1 2 1? -- 2ds 3S 3.6 3 I ins S1 S,3 3'h I 3 Ai 7 t 7J A 8.4 91 i 4 4 14 15 514 73 6 1� . Anvil Class 150(standard Weight)Malleable IrM MATERIAL SPECIFICATIONS • • Anvil C is ASME B 16.3 and Unions Malleable lleable to ASME Fittings 16.39 in the "List of Inspected Fire Protection Equipment Anvil standard weight banded pattern fittings in this catalog, ALL MOWS&TEES rii•iI0Dtrl ondt:.RGER ARE:Oo% TESTED and Materials" issued by the Underwriters' Laboratories, Inc. sizes 1/e NPS to 6 NPS (6 to 150 ON) inclusive, ore included MI"MUMOF IOOP51.(6.96orl GAS TESTED Ar a NOTE See tha;sheKa(Dab section for--. senses senperarvs ratings. See AmnfSior Web Dire for the(eau currant l,u _ uK,,t and appwrois PROJECT IN. . ...___ ._T._._.. . Project: APPROVAL STAMP: Oats: Phone: Architect/Engineer: Contractor: Address: Notes 1: ---- —__.________�- Notes 2: Anvil Cast&Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ralings•versus pipe sr-he <Ev 03 01060023 go to www.anvtlstar.corn or contact your local AnvifSlar representative dine. 1 ',. N IBCO` k _ . Q - .� Wviiw nibco corn s _ - :— . .. AHEAD OF THE :FLOW' ";� - 06/21/05 Class 125 Bronze Check Valves Dezmcficat:o" Resistant Horizontal Swing • Regrinding Type • Y-Pattern - Renewable Seat and Disc 125 PSI/8.6 Bar Saturated Steam to 353° F/178° C `r? ,2,- . 200 PSI/13.8 Bar Non-Shock Cold Working Pressure - • CONFORMS TO MSS SP-80 MATERIAL LIST T-413 PART SPECIFICATION Threaded 1 Bonnet Bronze ASTM 6 62 2 Body Bronze ASTM 8 62 3 Hinge Pin Bronze ASTM B 140 Alloy C31400 or (21.... __ B 134 Alloy C23000 • 4 Disc Hanger Bronze ASTM 8 62 or G.. ,-"•'..'-‘. 304 Stainless Steel'/4"th_ru'`:" sizes s Cry �' 5 Hanger Nut _ Bronze_AS_T_M B 16 r G•' +� � 6 Disc Holder Bronze ASTM 8 62— `�' 7 Seat Disc Water,Oil or Gas(Buna-N;(140 r Steam(PTFE)(Y) p 1 Bronze ASTM B 62(B) - •'S - - Viton N1 8. Seat-------- �__Disc Nut Bronze ASTM B 16 or 8 62 ' 1 9 Hinge - Bronze ASTM B 140 Alloy C32000 rot shown 7-413-B 9 e Pin Plug - -- -- --°y -- - - h,'•■,si p, "10 Seat Disc Washer ASTM B 98 Alloy C65500 or ASTM B 103 not shown 'Sizes V.",1".1W,and 11/2"only. o °6 r' DIMENSIONS—WEIGHTS—QUANTITIES �� \40 QQ I. �.�� Dimensions a�. 4��•,• tel Size A B Master I:�li:f ` '� <Ssl- In. mm. In. mm. In. mm. Lbs. Kg. Ctn.Qty. t:��{� a v. 8 .2 13 54 163 e t 050 0 23 5 I s.,� .� .. .... a/e 10 213 54 163 41 047 0 22 50 1/2 15 2.44 62 169 43 0 55 0 25 50 T-413-Y 44 20 2.94 75 188 48 0.90 0 41 50 OA NPT x NPr 1 25 356 90 2.31 59 t 46 066 30 11/4 32 419 106 2 69 68 2.17 099 20 - 1' 40 450 114 294 75 295 134 10 250 5 25 133 394 100 4 79 217 10 )IIIIIII ' 2'h• 65 800 203 506 129 1148 5.21 5 3• 80 9.25 235 6 25 159 17 53 796 4 NIBCO check valves may be installed in both horizontal and Ordering T-413 normally furnished with Bronze Disc(7.413-8) vertical lines with upward flow or in any intermediate position They will operate satisfactorily in a declining plane(no more Available with PTfE Steam Disc(T 413•Y)or CWP Disc Than 15') (T-413-W)or 300'f 57 PSI steam Viton Disc(T-413-V). •-Class 150(433)furnished for these sizes Warning-Do Not Use for Reciprocating Air Compressor Service \3:: :.:z.:,-E-: -."ERS•'5-s P'CC-E3U:°S' •:_ -_ • _- s:•_5:.• e.:.:.2 .:::::' 18 _.-SE;V'2ES'ii 1 888 446 4226•'AX 1 888 336 4226•iN'ERV. _. , • 5'4 2__:22'- �x ••- =2.=- ._ WWV+^.ibCO C7 INDOOR/OUTDOOR butterball ® BUTTERFLY VALVES VALVES LESS SUPERVISORY TAMPER SWITCH ASSEMBLY ... . . .- _ .,. _________-- ..4._•. -..- .._. .., . I --- -,- . - - • • , . _._ ... _..• „ —__-------- L - • - • - .. ‘,.. . - u• - . _ - BBVSC100 BBVSC100 3 piece with Uni-body with BB-SC100 (Threaded Ends) Grooved Ends Grooved Ends Sizes 1", 1-1/4", 1-1/2 ', 2 ,2-1/2" Size 2" Size 2-1/2" VALVES WITH SUPERVISORY TAMPER SWITCH ASSEMBLY 7 s•7 i . . AACY1d , .. • • - - i••.„ • . , . .. 0. .. .. • .. .. _ • • _ __ .,. -.I - - .. ., ,.. , . . 7---, L, - - -•• - - - THREADED ENDS NYC INDICATOR • BB-SCS02 kAvailable on both switched BBVSCS02 BBVSCS02 and non-switched modes.) 3 piece with Uni-body with ALL DIMENSIONS-INCHES Grooved Ends Grooved Ends Threaded Grooved Size 2 Size 2-112 " " . , SIZE; 1' , 1-1/4" 1-1/2"I 2' SIZE : 2" 2-112" B 3-15116' 4-9132 4-1,2— 5 1 B 5 5-13/32 C 1-9/16 1-15116 2.3/16 2-314 C 1 2-314 • 3.3/16 O 1-23/.32 2-7/64 2-3/8 3-1/16 D 3.1/16 3-1/2 J 4-15/16 5-1/8 5-19/32 6.1/8 E 5/8 ' 15/16 K 66 .73 .73 .79 F 5/16 : 518 L .83 90 .99 1.41 G i 6 • 4-1/2 'M-40 1.05 1.38 1 1.61 2.07 1- H 1 2-3/8 1 2-7/8 M-80 .96 1.28 ; 1.50 1.94 1 J 1 6-1/8 , 6-114 MATERIAL LIST 1 N-40. 2.25 2 • 25 i 225 , K ! .79 118 11 ,W6. PART ' MATERIAL T SPECIFICATION ' WI' iiii..'"T-T4 1-ij,32.1-ii.l& . -L T74-1. 1-1 29 i 1 • NA-4o- ' 2 47 m-4o ARE DimENSIONS uSING SCHEDuLE -- 7 --,,--- -7 ---- 1 Indicator S ltered troll 1 F0008P 40 PIPE M:Su; 1.S4 .2 3-2 2 Housing Bronze . ASTM 584 m-80 ARE DiMENSIONS USING SCHEDULE ...t446 ,..220."-: . 10 ; _. P9'ziy ze ron B i ,... i ASTM 584 8O PIPE - 4i-------:----— -144 t . 4 Handle . Brass N-40 IS FLOW RESISTANCE ExPRESSEDIN EQUIVALENT LENGTH OF SCHEDULE 5 Disc , Stainless Steel . Type 304 40 PIPE 6 Disc Seal EPOM Elastome i W IS THE WRENCH MAKE-UP LENGTH i---, 1 L7 Switch Housing ' Die Cast Alum:nurn._i_ Rev 1 • September 16, 2009 ' a j EASYPAC RESIDENTIAL TECHNICAL DATA RISER MANIFOLD ASSEMBLIES 2 :DN25 - � The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION Viking EasyPac Residential Riser Manifold Assemblies are available in sizes 1". 1-1/4', 1-'"2 . ana 2 for NFPA 13D and NFPA13R residential fire sprinkler systems. The configuration eliminates the need to drain the system before irsta ling the relief valve. while a built in test port allows hydrostatic testing without draining the system The EasyPac Residential Assemb:•es include pressure gauges Potter flow switches,3-way gauge control valve and 1"drain valve(or 1-1/4"for 2"Manifold) The EasyPac assemblies are made w steel bodies and are available in threaded or grooved connections. 2. LISTINGS AND APPROVALS Pressure Gauges: UL Listed. FM Approved Waterflow Alarm Switch: UL Listed- Category USQT,cUL Listed. FM Approved-Waterfiow Detectors. Vane Type. CSM Listed Ball Valve: UL Listed, FM Approved AGF TestanDrain Model 1000: UL Listed-Category VEHZ. FM Approved-Sprinkler System Alarm Testers AGF TestanDrain Model 1011 with Pressure Relief Valve: UL Listed-Category VEHZ,FM Approves-Sprinkler System Alarm Testers 3. TECHNICAL DATA r Viking Technical Data may be found on ' Specifications and Material Standards: The Viking Corporation's Web site at I Available since 2007. http:Nwww vikinggroup:nc com. Tne Web site may include a more recent • Pressure Rating: 250 PSI (17.2 bar)maximum water working pressure. edition of this Technical Data Page • Fabricated steel pipe. i_ • Available in male NPT threaded inlet and outlet connections using Schedule 40 steel pipe • Available in grooved inlet and outlet connections using Schedule 10 steel pipe. • Available with male NPT threaded inlet x grooved outlet using Schedule 40 steel pipe. • Riser bodies coated with black Ecoat. • Flow Switch:Two single-pole double-throw switches with Form C contacts rated at 15 Amps 125!250 V AC. 2.5 Amp 0-30 V DC Each switch can be wired for open or closed circuit operation.See Figure 1 Ordering Information: (Also refer to the current Viking price list.) • There are three different options available for the Residential line' Basic Residential EasyPac Assemblies with Ball Valve Drain(See Figure 2) Residential EasyPac Assemblies with TESTanDRAIN Valve(See Figure 3) Residential EasyPac Assemblies with TESTanDRAIN and Pressure Relief Valve(PRV)(See Figure 4) See Table 1 for Part Numbers. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Note:The EasyPac Residential Riser Manifold Assembly can be installed horizontally with flow switch on top.or vertically with flow upward Viking EasyPac Riser Assemblies use Potter VSR flow switches The literature that accompanies the VSR states that the switch should not be installed within 6"of a change of direction of pipe or within 24"of a valve.This is merely a recommendation to reduce the pos- sibility of the switch not operating while minimal waterflaw is occurring This is a recommendation only not a requirement 5. TESTANDRAIN VALVE OPERATING INSTRUCTIONS 1. To Test:Turn valve handle counterclockwise from"Off' to"Test-. The handle will stop automatically After test is completed retur^ handle to"Off 2. To Drain: Turn handle counterclockwise from "Off to 'Test". The handle will stop automatically. Depress "Push' button and turn handle to"Drain". When system is empty. return handle clockwise to"Off'position. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspect or, Testing and Ma,ntenance requirements 7. AVAILABILITY The Viking EasyPac Riser Assemblies are available through a network of domestic and rr.ternatiorra d.str;butors See The Viiung Co•- poration web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty. refer to Viking s current list price schedule or contact Viking directl; Porn, No. F_102407 Replaces page 31a-1 dated July 3'. 2009 (Removed note regarc the flow switch for Canada orders-rot, use the same riot sw t f•. ■ 3:b September 18 2009 EASYPAC RESIDENTIAL NIKING - TECHNICAL DATA RISER MANIFOLD ASSEMBLIES ' 2 D :23 - JN.5_ The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TESTanDRAIN Option: Table 1 -Commercial EasyPac Assemblies : lncli des a lest onfice with size specs':ec Inlet/Outlet Viking Part from 3 8 'K2 8 to 25K ESFR' depe^d,rg Pipe Size Connections Option Pipe Size Number cm the smatest sprinker irs!a'ed on the Bal Valve 15226 system Must add suffix to the part r.:1'oer Thread!Thread TESTanDRAIN Schedule 40 15227 , for the desired orrice s ze TESTanDRAIN and PRV 15228 Orifice Suffix: 1" 15243 A=3r8' rK 2 8) Bail Valve B=7r16'(K 4 2) Groove/Groove TESTanDRAIN Schedule 10 15244 C=1!2.1K 5 6) TESTanDRAIN and PRV 15245 D= 17!32.11(8 0) Ball Valve 14840 Thread/Thread TESTarDRAIN Schedule 40 15229 TESTanDRAIN with PRV Option: TESTanDRAIN and PRV 15230 I Includes:es:orifice and pressure rel e! Ball Valve 14841 valve The!est orifice must be speck(eri nosed on tie sma lest sprinkler insta lec o- 1-1.4' Groove!Groove TESTanDRAIN Schedule 10 15231 the system for 318' (K2 8)to K25 ESFR' TESTanDRAIN and PRV 15232 The pressure relief valve is not factory Ball Valve 14905 assemuied to the TestanDrain Must add Thread/Groove TESTanDRAIN Schedule 40 15233 r suffix to the pal number for the desired TESTanDRAIN and PRV 15234 t orifice size and pressure setting of the Ball Valve 14842 I pressure relief valve . Thread!Thread TESTanDRAIN Schedule 40 15235 Orifice Suffix: TESTanDRAIN and PRV 15236 A=3'8' (K2.8) i B=7'16'(K 4 2) Ball Valve 14843 I C= 1!2 lK 5 6) 1-1-2" Groove/Groove TESTanDRAIN Schedule 10 15237 D= V132 il<8 C. TESTanDRAIN and PRV 15238 PRV Suffix' • Ball Valve 14849 175 Thread!Groove TESTanDRAIN Schedule 40 15239 185 TESTanDRAIN and PRV 15240 195 Ball Valve 14844 205 225 Thread/Thread TESTanDRAIN Schedule 40 15241 250 TESTanDRAIN and PRV 14901 NOTE:It is important to note that the Ball Valve 14845 i pressure rating of the relief valve ndicateti 2 Groove/Groove TESTanDRAIN Schedule 10 15242 an operating range of pressure k r bo!I TESTanDRAIN and PRV 149CC opening and closing of the va're Standar: Bali Valve 14846 rel of va:es are required to OPEN in a range Thread/Groo:e TESTanDRAIN Schedule 40 15246 i of pressure between 90%anti 105%of tr.e.r TESTanDRAIN and PRV 15247 I rating The valves are required to CLOSE at ' a pressure aoove 80%of that rating Table 2-Pipe Diameters 1" 1-114" 1-112" 2" Pipe OD 1 315"(33 4 mm) 1 660 (42 mm) 1 900'(48 mm; 2 375 160 mm) Schedule 10 Pipe ID 1 097•'(27.9 mm) 1 45"(36 6 mm) 1 69'(42 7 m'r.: 2 16' 54.8 mm) Schedule 40 Pipe ID 1 049"(26.6 mm) 1 38-(35 1 mm) 1 61' (40 9 rnrri 2 07';52 5 rim) L Figure 1 -Flow Switch with Two Single Pole, Double Throw Micro Switches • I September 18. 2009 EASYPAC RESIDENTIAL R RISER MANIFOLD ! NIKING TECHNICAL DATA ASSEMBLIES - 2 DN25 - DN5f1. The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com • i-- - -F---- -H _ F -- H I ! rri---":-.5 1 vq+o i Imem — a ��a� 1 . -- I � D C .. I_- D ii ;.1.: i� A ' ' - ir�{ - �\ -- I � I,-. L. ';o, 1 - I J - i i1 - . ' B• (_,. f B 1" (DN25)1 1-114" -2" (DN32-DN50) II [ Figure 2-Basic Residential EasyPac Size A B C D E F G H I I 16-3,32" 14-15.16' 1" 6-3 16' 5,3 4 3-1/2" 8 1" (DN25)1 VSR-S F'on,Switch' V Hose (409) (379) (25) (157) 046) (89) (203' 16-1'2' 15 1-1/2' 6-3 32 6-11 32' 4.3/16 6.9/16' 1-1/4" (DN32) VSR-S Few S:vitcr' 1'NPT (41i3; (381) (38) 055) 1.611 (107) 12180 16-1,2' 15' 1.1/2' 6-7 32' 6-15.'6 4-5,16 9-'1.16 1-1/2"(DN40) VSR-S Flow Swdcr3 1-NPT (419) (381) (38) 056) 1'64) ;110) 1246' . 14-1/2' 13 -1'2' 6.7 16 5.51:64' 5' 9.23 64 2" (DN50) VSR Flow Sw tch4 1-1,4'NPT (369) (330) (-12)1 (164) 1148) (127) (238; 'The body of the V manifold is comprised of four 1°nipples and three tee's Dimension E is negative because the ball valve extends be ow the end of tre manifold oody `Mounted with included nipple(As shown above) Mourted with induced U bolt(Not Shown; —_-_ ---.------- Note: Dimensions may vary by± 1/4" (6.3 mm) 4.,...., GUARDIAN FIREEQUIPMENT,INC. DETAIL AND SUBMITTAL SHEET �j / MIAMI,FL --- Ph.800 327 6584•Fax 800.827.3869 5000 Series - Hose Valves Project/Location: Date: Architect/Engineer: Qty: Contractor: p'Appropriate Selection Female x Male Angle Valves-Used as fire hose outlet connections Female NPT inlet x Male hose thread outlet,300 PSI,cast brass,UL listed/FM approved r--A - r_ Model No. Size A B(Open) C D Swing Radius ❑ 5010 11/4"x 1'r4' 4" 7W 2Y. 8 p ❑ 5015 2W x 2W 51/4' ®® 2W ��L T.-# Optional Finish:❑-B Polished Brass ❑-C Rough Chrome Plated ❑-D Polished Chrome Plated -'•- rr-( Threads:❑UST ❑Other -- J-C 5010/5015 Female x Female Angle Valves-Used with hose rack assemblies Female NPT inlet and outlet. 300 PSI, cast brass,UL listed/FM approved. _-A -.. f -f- Model No. I Size A I B(Open)I C I D Swing Radius El 5020 11/4"x 11/4" 7'/: B p ❑ 5025 Optional Finish:❑-B Polished Brass ❑-C Rough Chrome Plated ❑-D Polished Chrome Plated ! 41 Female x Male Pressure Restricting Angle Valves-Used as fire hose outlet connections Field-adjustable C restricting mechanism reduces water pressure under flowing conditions(175 PSI max inlet) When full flow 5020/5025 is required,restriction can be over-ridden by trained personnel Female NPT x Male hose thread outlet, 175 PSI,cast brass,UL listed/FM Approved. r t--1_jj i-: Model No. ( Size A B(Open) C D Swing Radius I i ❑ 5030 1 2W x 1W 4' ���� 1_- / ❑ 5035 2W x 2 51/4" 11W f— ! Optional Finish:❑-B Polished Brass ❑-C Rough Chrome Plated ❑-D Polished Chrome Plated ld^ Threads:❑NST ❑Other --4-C 5030/5035 Female x Female Pressure Restricting Valves -Used with hose rack assemblies. Field-adjustable re- stricting mechanism reduces water pressure under flowing conditions(175 PSI max. inlet) When full flow A- is required,restriction can be over-ridden by trained personnel.Female NPT inlet and outlet,175 PSI,cast i��°—, brass,UL listed/FM Approved. I -j' Model No. Size I A B(Open) C D Swing Radius 1 (_-r-__-_ p ❑ 5040 11/4"x 1W 4' 8' 2W 2" ME ❑ 5045 21/4'x 21/4 5W 11W 3W 2W 1` r''� Optional Finish:❑-8 Polished Brass ❑-C Rough Chrome Plated ❑-D Polished Chrome Plated 5040/5045 Caps with Chains-Caps with Chains-Used to protect hose Reducer-Used to change outlet size.Rigid pin thread outlets on valves and hydrants lug',female x male threads Cast brass caps(pin lugs)'or red plastic caps(rocker lugs) Model No. 1 Size Threads: Model No. Size Type ❑ 3315 2%"x 1%i Threads: DUST ri.. ❑ 5515 1W Brass ❑NST Optional Finish: ❑Other ❑ 5515P 1%i Plastic ❑Other ❑-B Polished Brass ❑ 5525 21/4i Brass l ❑-C Rough Chrome Plated ❑-D Polished Chrome Plated ❑ 5525P 2W Plastic 'Optional:❑-RL Rocker lugs Optional Finish:0-B Polished Brass 0-C Rough Chrome Plated ❑-D Polished Chrome Plated 'Optional:❑-RL Rocker lugs . . - . . ` GUARDIAN ifFIREEQUIPMENT,INC. DETAIL AND SUBMITTAL SHEET I MIAMI,FL / Ph.800.327.6584•Fax 800.827.3869 6300 Series - Fire Dept. Inlet Connections - Bodies Project/Location: Date: Architect/Engineer: Qty: Contractor: /Appropriate Selection Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies. Provides 250 GPM flow(minimum),per 2'/:"inlet. A ' I Two and three-way-inlet connections feature clappered brass bodies(straight �1-- I or angle pattern),with female hose thread swivel inlets and female outlets.Cast —B brass construction, standard. 6314 Two and Three-Way Connections - -- B---n Model No. Outlet Size Clappers A B f ' /////\\\\ i ❑6314' Back 4"x 2'/i x 2'h" 1 _y 5'/i 8'/: _ 1 f ❑6315' Angle 4"x 2'/i x 2'1i 1 8'/: 8'l: A '• ' ❑6324 Back 4"x 2'h"x 2'12' 2 7'/: 10'/i ��"� ❑6325 Angle 4"x 2'/2"x 2'/i 2 81: 10'/2. 6315 El 6326 Back 6"x 2'/2"x 2'/i 2 71: 101:' ❑6327 Angle 6'x 2'/i x 2'/2" 2 10" 10'/2" f---- -----1 ❑6336 Back 6'x 2'/i x 272"x 2'/• 3 r 10'/2' f_ 13'/: `-.• ❑6337 Angle 6'x 2'/i x 2'/2"x 2'li 3 11'/2" 1 14'/i A , Body Lettering , i�- ❑AUTO SPKR ❑STANDPIPE - •- B - ❑Blank(unlettered) 6324/6326 . 'Auto Spkr lettering only Optional Finish:❑-B Polished Brass Threads: l t 1, ❑-C Rough Chrome Plated ❑NST ❑-D Polished Chrome Plated ❑Other A L.. _ • . 632516327 Plugs with Chains and Break Caps-Used to keep fire dept inlet connections free of debris and f _ protect female threads. ∎`-�~ . Plugs with Chains Break Caps A•\% V. Model No.I Size I Type • ' Model No.I Size I •Type I I _ E - • ❑ 6404 2'/i Brass 1 ❑6406 ' 2'h" Aluminum L--- B -- I Optional Finish: 1 ❑6407 2'/i Plastic 6336 ❑-B Polished ❑-C Rough Chrome Plated Threads: Adjustable Plugs • B ❑-D Polished Chrome Plated 0 NST Model No.I Size I Type �� ❑Other ❑6408 2'/i Aluminum 1 -mot I ID 6409 ® Plastic A i.' -r7 I 6337 Contact factory for current listings and approvals