645 OCEAN BLVD - RESID. ADDITION PERMIT.r. t CITY OF ATLANTIC BEACH Al t 800 SEMINOLE ROAD s? ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 -►'f3 sf RESIDENTIAL ADDITION MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-RADD-729 Job Type: RESIDENTIAL ADDITION Description: DUPLEX TO SFR SEE PERMIT# 16-SFR-566 Estimated Value: $313,000.00 Issue Date: 4/1/2016 Expiration Date: 9/28/2016 PROPERTY ADDRESS: Address: 645 OCEAN BLVD RE Number: 170126-0000 PROPERTY OWNER: Name: Indriolo, Joseph Address: 645 Ocean BLVD GENERAL CONTRACTOR INFORMATION: Name: EQUITY BUILDERS OF FL LLC Address: 2650 ROSSELLE ST STE 2 ST QA JOSEPH C INDRIOLO Phone: - - PERMIT INFORMATION: FEES: ENG REV RESIDENTIAL BLD $100.00 BUILDING PERMIT FEE $460.00 STATE DCA SURCHARGE $16.79 PLAN CHECK FEES $559.50 STATE DBPR SURCHARGE $16.79 UTIL REV RESIDENTIAL BLDG $50.00 Total Payments: $1,203.08 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. • oi ,..16 City of Atlantic Beach � a Building Department fJ APPLICATION NUMBER ca (To be assigned by the B • •• P-; -n . 800 Seminole Road j -0 Atlantic Beach, Florida 32233-5445 ( � �• (Q i Phone(904)247-5826 • Fax(904)247-5845 M • ' E-mail: building-dept @coab.us Date routed: 2 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM (.0 Property Addres : � (VA SC. V I • - •artment review required Yes No ildin g Applicant: U. i , 1 J C4 , Planning &Z�uing) -ree.Admmin.istrator Project: Al/f r- g MEI I J , PublicWokks--) Utilitie \d/ •T � °ubl afety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ['Approved. Denied. (Circle one.) Comments: iit.arjj BUILDING PLANNING &ZONING r.Z-f/d Reviewed by: i!!!� Date: TREE ADMIN. Second Review: A roved as revised. pp ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by • rL---'";"---- --' Date: 3/3t//1 FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 C;a y:lr� CITY OF ATLANTIC BEACH FIL. , Building Department E COPY �. 800 Seminole Road ier rr Atlantic Beach,Florida 32233 (904)247-5800 PLAN REVIEW COMMENTS Permit Application # / G - R D b-7 a c) Property Address: 6 4/5- c7cea n Oka/ Applicant: �gli 7 /y A, ./ /ale r 3' Project: Con verf Vvie x As 3/t'/. / a a,n Qdo/i/icy) This permit application has been: Approved Pille. 3/2"1/46 IM -atteien: 0 & &/Yl r/ 02 co/J/9 S O / a /eyed St.r ve . - / ,z- b h✓ 0 door" -6x6-& I d cam, 0l nof- © The, -�',r S f -�' ©o cc� o be Q cce pLo 6/e, . F736 - P-esSeel kat 15 /-t 6d, ),zyyx Sec/ion R ado, R 3,)0, I. / Pero.r- .i -/Act-/ 4A,2-re e cz d9 " cIeaY seae-Q. The GY`6t` c 6`?" kior7'/ Prou;CJ-e IAaf (vken -P,1/, o/enc. C& S'vb /r7,/,4 Ca/cv/aIia✓I F I SAOw Roo74 V!'/1I11a-/-io,-\ 2e'v/i'e — /'h ei& (iiryy J -/•fJ)- l'/00n L,SA1,`/15 c {p0 41, -e ✓ PIaA . -- k)/%en =Slam et CoUn-/Pr 710P a f S/au� j 6e Sore ,La co,,, sc, 11- Lv I 'I JA your l i c-e n seal e l ec v s c..:u ►. for -Ike p e c e p c/. O e o,;--e mei / Per 41,-e I /Ve' „Pc / , 1 1 �� Fl) OO7 *11- - 1cSu , 1d/-ri St b-epur fr ell /s Prod uc// Ipploktl PoY r S C a co i'�S 1 `rv✓' ct /I coy-y.120)1-0,1J-" $ C 0C�o�1/✓1 �q Y ` .0 S. r - J R-Q pl., lc, ,`1P vi s a Bova w 4-J, ui r■ d-Jen 1-eHPr c o/dreS'Si/J eac b ', ON , at Please re-submit your application when these items have been completed. 3J, //6 nix Reviewed By: Date: d PPUr fwS' 3l10 G 17)^ ' C-Y S- a <L� FILE COPY•_0 f r.�r, CITY OF ATLANTIC BEACH <s1 800 Seminole Road J Atlantic Beach,Florida 32233 j s r� Telephone(904)247-5800 FAX(904)247-5845 '''-1.JFI1rP / REVISION REQUEST SHEET Date: <-3'/ ` '/ Received by: Resubmitted: Permit Number: =- /a/� Original Plans Examiner: Project Name: nay , 70 5 s oe—,..,—rL,_ Project Address: &:/-71,5- O(,v"_,, fi/fr Contractor: gy c 177 i ,doe,./5- Contact Name: ,c___ Phone i c//. 6 '7 < 0/2'2- Contact e-mail: Rem/Plan Check/Permit Fee (s) Due: $ Description of Proposed Revision to Existing Permit: J. .) r—criNs f s€"= C :a/Gtr47je /15 717 SX,:'w /c 0-1 te42 7g9%c ,-! ✓'eeiL,` V`h7 A%r✓ ,4-,z , 5 a .z q' a-- / Additional Increase in Building Value: $ O Additional S.F. /'_ Site Plan Revised: Public W/U Approval: By signing below. I(print name) CIO., - 44 ill-; so 4 affirm th. 1- .I eve revision is inclusive of the proposed changes. ri ECEIVE01 Signature o •ntract.� i -f g /Agent(Contractor must si:n if increase in valuation) Date MAR 1 // 11111 4 2016 f 6 Office Use Only Date: 21 6 Approved: // ( Rejected: Notified by: Plan Review Co ments:�, ii / Pprcve Q s S rbyn.r lied. Department review required Yes o Building 21 Planning &Zoning // 1 Tree Administrator Public Works ns Examiner Public Utilities j f //‘ Public Safety l Fire Services Date Created 8/20/15 Rev.2 a _.„........,,,,,,,.,„,_, -1 JAA ARCHITECTURE INC. :. 4 JAC 90NVILLE.FL 32205 2716 Sr.JoHnes Ave. 3.,'a,-xe LIC:AR92740 -`^+ ';mow P.(904)379.5108 R m ,s„ _ E:JGMNe}JAAARCNIT[CTURE.CGM ARCHiTECTJRE INC City Review Comments Project: Indriolo Residence FILE COP', O Submission No.: Date of Issuance: 03.14.2016 Submitted JAA Architecture By: 2716 St. Johns Ave. Jacksonville, FI 32205 (904)379-5108 2� M Permit#: B-16-SFR-566 Description: The purpose of this submittal is to provide responses regarding plan review comments. Departments Initial Building 1. Submit 2 copies of a legal survey. To be submitted by owner. 2. The first floor bathroom door(2-6x6-8 HC)will not be acceptable. FBC-Residential 5th Edition Section R320, R320.1.1 requires that there be a 29"clear space.The 2'-6"x6'-8"won't provide that when fully opened. 2'-6"x6'-8"changed to a 2'-8"x6'-8"door to comply with 29"clear opening per FBC Residential 5th Edition. 3. Submit calculations to show roof ventilation requirements. Roof vent calculations added to sheet A3. 4. FYI; First floor lighting&power plan—kitchen island&counter top at stove; be sure to consult with your licensed electrician for the receptacle requirement per the NEC 2011. Note added to sheet El. 5. Fill out the building departments product approval forms(2 copies)for all component&cladding items. To be handled by owner. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH FILE COPY - - 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904)247-5845 16,-( 40D-7 Z Job Address: l'P _ i-1.-.7 Gib,,,-, >/c-d. Permit Number: Legal Description 7- 15 /G, -�, - - ' G Parcel# /70/X 6d DO _,) Floor Area of Sq.Ft. S .Ft Valuation of Work$ ySc%o o° — Proposed Work heated/cooled iY non-heated/cooled Y44 X13, tied . Class of Work(circle one): Ne dition 'Alteration\ Repair Move Demolition pool/spa window/door Use of existing/proposed structures) (circle one): Commercial Residenti. If an existing structure,is a fire sprinkler system installed? (Circle one . No N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: • ‘,(744,7‹ / c� ' Property Owner Information: / Name: d`o X __7---7,,,4-,a o Address: Xjr' &c,2_,,-._,, y!City .471-'l,--,41.6 u,_- Statei%Zi p 39-, 33 Phone fie/ • '/,/ r :�- E-Mail or Fax# (Optional) • Contractor Information: CONTRACTOR EMAIL ADDRESS: Company Name: -,., u,/ ; ,>747,C76.-,-,9?-0---- Qualifying Agent:_ .7L__ .�,di.- ,/G Address:)&SL.-‹72 X.' Sfru./ City ,,4/2,4,,i,/Lc... State L Zip ..??-,)-.6 Office Phone �D y- 39P /c Job Site/Contact Number 9 /- 7 y p — State Certification/Registration# (2 C/5-// "."LL, c`'lL s/ Fax# �� 3jlo �SS�S Architect Name&Phone# .,74- 7111—e_.-1L, 6i, ,i . _ 70y- J 77 5706- Engineer's Name&Phone# Fee Simple Title Holder Name an. Address Ai/A. Bonding Company Name and Address /4/ Mortgage Lender Name and Address /f1/A Application is hereby made to obtain a permit to do the work and installations as indicated. I cert that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is sus ended or abandoned for a period of six 6)months at any time after work is commenced. I understand that separate permits must be secured for Electrical'York,Plumbing,Signs, Wells,Pools,Furnaces ,Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby ert that I have read and examined this a placation and know the same to be true and correct. All provisions of laws and ordinances governing this .ype of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the 7rovisions of any other federal,state, or local law regulating construction or the performance of construction. >ignature of Owner Signature of Cbntract 'rint Name , // - f� ........... ... .... .... ,,. v� Print Name 3efs e its -/ Day 4 ,.11 II_ 1! fa "':L., '-4...:#,- ._".�"�� •• • �� TON;cln; ER I ay of , 20 I M%C01'.iiISSION#FF924951 ±_ Ar 1■ I EXPIr3ES:October 6,2019 '".. rota ,---=: lc �_ MIL {"aa run Notaq P'.lIZZO Revised 01.26.10 ■ I DO NOT WRITE BELOW- OFFICE USE ONLY Applicable Codes: 2010 FLORIDA BUILDING CODE Review Result (circle one): Approved Disapproved Approved w/ Conditions PI 7 Review Initials/Date: 3/L/ 1/ b 1 COPY Development Size Habitable Space e2 to/ t S.F.Non-Habitable Impervious area Miscellaneous Information Occupancy Group te -3 Type of Construction U (3 Number of Stories Zoning District Max. Occupancy Load Fire Sprinklers Required Flood Zone A Conditions/Comments: -1 Z°1 S1 �� City of Atlantic Beach a � � APPLICATION NUMBER �� III' Building Department (To be assigned by the Building De.artment.) P. 800 Seminole Road „,,,,, -,, Atlantic Beach, Florida 32233-5445 c r / Phone(904)247-5826 • Fax(904)247-5845 3 .11v ' JF �a E-mail: building-dept @coab.us Date routed: 7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM /, Property Address: L, �� �C'fJy1 [A� Department review required Yes No 1 Building _ _. Applicant: _,`k i . , iv 1 cz-.R , Planning &Z.•.-. r 4.....-re- '.ministtator Project: ,%, - / nit I I , Public Wo . - 4 -u.lic Utilitie Y v /f-DT c afety Fire Services Review fee $ Dept Signature i. Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING VO PLANNING &ZONING Reviewed by: 1 Date:3/'2///6 TREE ADMIN. Second Review: ❑Approved as revised. °D-"red. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 City Q Zcl APPLICATION NUMBER �•�, Cit of Atlantic Beach Building Department \( ' (To be assigned by the Building De•artment.) 800 Seminole Road — �, / i �� , Atlantic Beach, Florida 32233-5445 f�EC IV 1 .' Phone(904)247-5826 • Fax(904) 047-5845 3 j 9' E-mail: building-dept @coab.us MAR 0 9 2016 Date routed: Yi City web-site: http://www.coab.us I • APPLICATION RE CKING FORM Property Addres : lJ i/ t�(. P Y L f fi A/ /c/ vd u - . • . review required Yes No . ing Plan &Z••' • _� Applicant: ! j �i�l I ,--aerator �_� ---- ing Project: 1t. ,/ a nth i I Public W• Y / /1- Th Fire Services Review or Receipt Date Other Agency Review or Permit Required of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: V I C TREE ADMIN. Second Review: Approved as revised. Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ElApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH • 800 Seminole Road,Atlantic Beach, FL 32233 Office (904)247-5826 Fax (904)247-5845 Job Address: _ 7 -� L � ..---PA',./_- Permit Number: Legal Description `- > A., —,3s-- _ ,-py c Floor Area of Sq.Ft. Parcel# /),I,:,,-) Valuation of Work$ /Sc;c c Proposed Work heated/cooled t !� =l� ooe non-heated/cooled j��" Class of Work(circle one): New Addition J Alteration Repair Move_Demolition pool/spa window/door Use of existing/proposed structure(s) (circle one): Commercial .Residential If an existing structure,is a fire sprinkler system installed? (Circle one No N/A Florida Product Approval# For multiple products use product approva form Describe in detail the type of work to be performed: 4' (.c n/,-,, ai <, ,/s' !-1 /2 .7`-�---, /,,,,- 0. (L L Property Owner Information: , Name il(- / ( .,,,, , r i Address: r A-, /�'_ — / .�City A. .-<17.e. ;-2, ; C� Stater.-:-L-Zip 7:a a ji Phone d Y-6-70/• ,/Y;1- E-Mail or Fax#(Optional) Contractor Information: CONTRACTOR EMAIL ADDRESS: Company Name: ., � �,/ �� Company tiL". ,, l ' 'G/`,-'"fg Qualifying Agent: •�� ��«/7i,. d/c %t.s- /' -S/rt:c"/" City Office Phone •37 t' , e.3'7 °d4/4- State AL Zip ,1;r a- y Job Site/Contact Number 7�.y- ���"ily Fax# J` y- 1�e s y."- State Certification/Registration# r(2C 7 S 7/ ",_., Architect Name&Phone# _,7'-if /,,k4 0 ; A c_ 7()7. �_ Engineer's Name&Phone# ' // ' ��'-"'� Fee Simple Title Holder Name and�Addre s ,ij l�arK/4A7 �,L �'�/. ���. `� Bonding Company Name and Address A .+ Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for aLperiod of six(6)months at any time after work is commenced. I understand that separate permits must be secured for ElectricalWork,Plumbing,Signs, Wells, Pools,Furnaces,Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby ert that I have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the 7rovisions of any other federal,state, or local law regulating construction or the performance of construction. gnature of Owner ��'��-- Signature of Coontractbr 'Tint Name / '�--� r /l "..._,,, f r v Print Name 3ef• , � �• !! 70t:aln,� � I ay of 20 1 MY Cnhl,iiISSION#FF 924951 �� I :,1 f EXPIRES:October 6,2019 I Iota a is O_ � F ,. :,n, a IIM Notary P, i i�-rZ , :tut-i�+y�+.1C Revised 01.26.10 City of Atlantic Beach FIVFD APPLICATION NUMBER Building Department n� (To be assigned by the Building De.artment.) 800 Seminole Road t� , j � Atlantic Beach, Florida 32233-54 5 MAR 0 9 Z016 Phone(904)247-5826 • Fax(9 )247-5845 ! E-mail: building-dept @coab.us CY: Date routed: 2 City web-site: http://www.coab.0 16 < A-DO 7z9 APPLICATION REVIEW AND TRACKING FORM (12 Property Addres : �� A�1y/ 1/70 - •artment review required Yes No 1 I ; : rig Applicant t✓(, 1 A Planning &Z.•--. -re- '•ministrator Project: et II u. is Utilitie v\// �i alZ fety Fire Services Review fee $ Dept.Signature; Other Agency Review or Permit Required Review Receipt Date of Permit or Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: - Approved. ['Denied. (Circle one.) Comments: 4%iJ 9 11,1 PLANNING &ZONING Reviewed by: AA- /" Date:3 Z31(L TREE ADMIN. Second Review: Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: QApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 14ifleditnAd_ Lo * Si KY° yo,ro _ ; Ira -ftd /0 5( Iv t4/ 4 1401(eie 76 cot I ? 401 Puk_ I X ; 1247__ 4 2.21f1( k Jr3 4 # 1fk -1-; L e ii P itive9 f44 0 pit e- #C la/ MO K3 Z7 Lk iiti,d7rie I__/ X_r4_ .- 4,... _fart) — 3 6_IJI 1114A , — 11-4 a A 3( / i " _ _ fiv4figei&k, /3 g .., _ Ar k i'vl -.-- log /4 2- -54e/I /4 av 1 940 / Y 6 to Wai ,15eJ k 49Z 4.,, /ei 1 _ _ L ---- —-- pf ZONING REVIEW COMMENTS rj A City of Atlantic Beach T3 x-. - z Building and Zoning Department 800 Seminole Road Atlantic Beach, Florida 32233-5445 ,.r J )' Phone: (904) 247-5826 Fax: (904)247-5845 Email: dreeves @coab.us Date: 3/25/16 Permit: 16-RADD-729 Applicant: Equity Builders of Florida Review: 1st Address: 2650-2 Rosselle St, Jacksonville, FL 32204 Site Address: 645 Ocean Blvd Phone: (904) 398-1044 RE#: 170126-0000 Email: N/A Correction Comments 1. Survey: Please provide a legal survey. 2. Shed Setbacks: Setbacks for detached structures like sheds are 5 feet from side and rear property lines. Please show that the relocated shed meets those requirements. 3. Fence Height: Please show the fence height of new portions of fencing. 4. Pool Permit: Please show that the pool is to be permitted separately. Q9)‘ ,,, ./ Derek W. Reeves \\ L Planner �V ��7 dreeves @c•. . . ../ \.e> 0 leek la-Z V /Eget Z Ste e v 1 , c kr-c 1'' s--3- 9 v, ,.....,\ ...} MAP SHOWING BOUNDARY SURVEY OF 77-IE WEST 1 /2 OF LOT 4, DANIEL AND HACKETT'S REPLAT OF BLOCK 16, ATLAN77C BEACH, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 9, PAGE 35, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. FILE COPY 20 10 0 20 40 SCALE IN FEET 1" = 20' ( ) LOT 5 FOUND 81.50 ZR PPE(NO 1/2 IRON N8934 43"E 1.29(M) P Now)IRON•O -6. ' A/C o' n p PAD >.•-•4 WEST 1 / 2 0� EAST 1 /2 gii Cn� LOT 4 p0 2-STORY SHINGLE 2.00 BLOCK 16 N LOT 4 0 C 0 j545 & 647 j A/c 3 O rn -0 cA #' PAD N fl y OO o OD N o 0 O CC/) 19.0' 34.2' K o, +: ISA FOUND 1/2 fltoAr� Fo mD 1 IRON .8935$5 W 80. A ' ROD O 1 2) PPE 'LB 3672' 80.83'(R) LOT 1 LOT 2 LOT 3 '" `. 1�/ D siit MAR 1 4 2016 I 1 1 NOTES: 1.) BEARINGS SHOWN HEREON ARE BASED ON THE EAST RIGHT OF WAY LINE OF OCEAN BOULEVARD BEING N 00179'32" W AND ARE ASSUMED. 2.) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A 7777.E �c ,� COMMITMENT OR REPORT, THEREFOR THERE MAY BE ADDITIONAL _i MATTERS OF RECORD NOT SHOWN HEREON THAT MAY BE FOUND IN JEFFREY H. WEINERT THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. ••IDA REGISTERED LAND SURVEYOR NO. 5748 3.) THE ABOVE CAP77ONED LANDS LIE WITHIN FLOOD INSURANCE ( NOT VALID WrtUHOUT THE SIGNATURE AND THE ORIGINAL RAISED RATE MAP, COMMUNITY No. 12031C, PANEL 0409 H, DATED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER 6-03-13. JJEFFREY H. WEINERT P.S.M. 5014 KINGSMEADOW LANE HJACKSONVILLE, FLORIDA 32217 W (904) 509-8562 W.O. NO.: 15-103 SURVEY DATE: 7/01/15 DRAFTED BY: J. WEINERT CHECKED BY: J.H.W. CAD FILE: 15103.DWG FB 142 PG 03 ' b b O `Y . O O 0" 5. 1 a. a. : p 00 ■J ch c!i A w N 5N c� w N . Cil <D o .0 (D p m m d � a � d n x � z Qa .� � • � o wosr . .� O P.'i> X' O Sv O a 9. 6 ¢. = cD co cro O c o C Pz k. p N O r LD 4 O, w , . , , ......., i O O N Iro \, 4\ O C0 N cn �7 - * "':; pow o o ° is c' O '1 d `� Q- x 0 °c , O u.�.r N y 4 .. �. o' CD -t O �C \ p 5, c O c� Y � � � CD y it nil N.It o i bd Uj 04 rli r. Gl � CO .�O \ b c o x 1�1 °Q P " 2 o�go 0 c it rm ° 8 :)'C) g (( a o _ p (D (D O cr N • .,D L J P n n . 01 u 4 W N .-� O Po �1 O" (•i W N -. g — p o Oo :1 O� to ? W N :— OQ N I' p cno ,�~-' o o v o o > 0 0 C 4 m � n o o a z o . 0 0 . o 0 0o Q E. g o E 't7 ,Ti E. tii t. Po '-- a ¢ U0 . Ao do 'O rDD '0 = ao P n �. O " ° o C P11 \ 0 O cG d o E.CD 174 0 (5 o cA 5 . o .-n C I . ■ 4 ta 0 f r. 4 I , N d et t 'N Po (` ,,,,i‘.::: o a. 0 , , , i . , I 1 4 o VI Y F O n AD It - i P '71 ril el n y eD eD .— - w N O oo --.1 01 v w N "-. v CT LA w • •� C O ,'v UI ' n o o a R o C 0 0 o C y y En a 0 I 1 1 to e., C A "'t . 1 b ri O c. C I d rA A 2. b a. O Aa O O 5 y eD D, eD It I. I • - , I r 0 A to 4t n H (i 4 n n - s• n 5 0 CD N •-C O V� ) . O� °0 \ Z z o 0X tll a DI ° � � N CD o � so a ... " cr 1:4 o o n \ Q- (• ~• t. 0 0 CD C et `) 00 mg C i� �. 0 eD 6 Go c'T'cr 4- `° O 0 0 — � • � 0 m X .� 4 0 co 0 o co fD a 0 O O vi ^ a �� J Cig CL O ci) .�. o `C ,__, 'O a. -.LT w O .-,' O N o 1"4t 1 OG ' 5 w A 5. II CD 0 co co CD o AD eofe It 0 .� 0 o o `0 0 co 0 �. O. o O CA � P. N Q. -t 0 0 O• 5 0 0 cu co cn FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) ..,n DISPLAY CARD r®= m ESTIMATED ENERGY PERFORMANCE INDEX* = 88 n The lower the EnergyPerformance Index, the more efficient the home. O w 645 Ocean Blvd, Atlantic Beach, FL, 32233 "'C 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=19.0 3088.20 ft2 b.Frame-Wood,Adjacent R=19.0 384.92 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 1564.00 ft2 6. Conditioned floor area(ft2) 2618 b. N/A R= ft2 7. Windows** Description Area c. N/A R= ft2 a. U-Factor: Dbl,U=0.35 547.33 ft2 11. Ducts R ft2 a.Sup:Attic,Ret:Attic,AH: Foyer 6 261.8 SHGC: SHGC=0.27 b.Sup: Attic, Ret:Attic,AH:Foyer 6 317.4 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 23.4 SEER:14.00 SHGC: b.Central Unit 34.6 SEER:14.00 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 23.2 HSPF:8.20 Area Weighted Average Overhang Depth: 3.762 ft. b. Electric Heat Pump 32.8 HSPF:8.20 Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14. Hot water systems ft2 a. Natural Gas Cap: 1 gallons a. Floor Over Other Space R=0.0 1264.00 ft EF:0.82 b.Slab-On-Grade Edge Insulation R=0.0 1054.00 ft2 c.other(see details) R= 299.00 ft2 b. Conservation features None 15.Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building STq :, Construction through the above energy saving features which will be installed (or exceeded) �F rfi'``t, in this home before final inspection. Otherwise, a new EPL Display Card will be completed 'I ,,„".•$, based on installed Code compliant features. ti ',,,,r ,, Builder Signature: Date: 5 ./6 ` 0 A% : Address of New Home' (, /L �.0 City/FL Zip: ��� •iy civ ,. c,`� „, S Gam, o ,, D t1 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 t, FORM R405-2014 FILE COPY RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the reside ntial Simulated Performance method shall include Q' This checklist Y' A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page) and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). r Energy Performance Level(EPL) Display Card(one page) E / Mandatory Requirements(three pages) Required prior to CO for the Performance Method: Cpl Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) miFt ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge®-USRCSB v4.0 3/4/2016 8:27:54 AM Page 1 of 1 t , FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Indriolo Residence Builder Name: Joe Idriolo Street: 645 Ocean Blvd Permit Office: City,State,Zip: Atlantic Beach, FL,32233 Permit Number: Owner: Joe Idriolo Jurisdiction: Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(3473.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=19.0 3088.20 ft2 b. Frame-Wood,Adjacent R=19.0 384.92 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1564.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1564.00 ft2 6. Conditioned floor area above grade(ft2) 2618 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11. Ducts R ft2 7. Windows(547.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH: Foyer 6 261.8 a. U-Factor: Dbl,U=0.35 547.33 ft2 b.Sup: Attic, Ret:Attic,AH: Foyer 6 317.4 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 23.4 SEER:14.00 c. U-Factor: N/A ft2 b.Central Unit 34.6 SEER:14.00 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 23.2 HSPF:8.20 SHGC: b. Electric Heat Pump 32.8 HSPF:8.20 Area Weighted Average Overhang Depth: 3.762 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems 8. Floor Types (2617.0 sqft.) Insulation Area a. Natural Gas Tankless Cap: 1 gallons EF:0.820 a.Floor Over Other Space R=0.0 1264.00 ft2 b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 1054.00 ft2 None c.other(see details) R= 299.00 ft2 15.Credits CF, Pstat Total Proposed Modified Loads: 69.37 Glass/Floor Area: 0.209 PASS Total Baseline Loads: 78.52 I hereby certify that the plans and specifications covered by Review of the plans and .• '1 E STA '. this calculation are in compliance with the Florida Energy specifications covered by this ',4� p Code. calculation indicates compliance „,,, ' :tia s1 with the Florida Energy Code. I.- zuut '� d'A%`gyp PREPARED BY Before construction is completed a 4'4' - V 5 DATE: this building will be inspected for rkIrg O compliance with Section 553.908 I hereby certify that this building, s designed, is in compliance Florida Statutes. - ':- . ' with the Florida Energy Code. g g p C'o. W 14. . OWNER/AGENT: BUILDING OFFICIAL: j� 3 } DATE: DATE: VVV f/O,`C� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. Ronald E. Miller,Jr. Certified Commercial EnergyRater#960 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: Indriolo Residence Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2618 Lot# Owner: Joe Idriolo Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Joe Idriolo Rotate Angle: 0 Street: 645 Ocean Blvd Permit Office: Cross Ventilation: County: Duval Jurisdiction: Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V1 Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range V FL,Jacksonville FL_JACKSONVILLE 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 1054 10887.8 2 Block2 1564 18251.9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Foyer 118 1218.9 No 0 1 Yes Yes Yes 2 Kitchen 218 2251.9 Yes 0 0 1 Yes Yes Yes 3 Mudroom 40 413.2 No 0 0 1 Yes Yes Yes 4 Dining Room 190 1962.7 No 0 0 1 Yes Yes Yes 5 Living Room 315 3253.9 No 0 0 1 Yes Yes Yes 6 Office 115 1188 No 0 0 1 Yes Yes Yes 7 Bathroom 1 58 599.1 No 0 0 1 Yes Yes Yes 8 Master Closet 110 1283.7 No 0 0 1 Yes Yes Yes 9 Master Bath 210 2450.7 No 0 0 1 Yes Yes Yes 10 Master Bedroom 220 2567.4 No 2 1 1 Yes Yes Yes 11 Bedroom 1 175 2042.3 No 1 1 1 Yes Yes Yes 12 Bedroom 2 175 2042.3 No 1 1 1 Yes Yes Yes 13 Bathroom 2 85 992 No 0 0 1 Yes Yes Yes 14 Bedroom 3 145 1692.2 No 1 1 1 Yes Yes Yes 15 Bathroom 3 65 758.5 No 0 0 1 Yes Yes Yes 16 Bedroom 4 180 2100.6 No 1 1 1 Yes Yes Yes 17 Laundry Room 40 466.8 No 0 0 1 Yes Yes Yes 18 Hall and Stairs 159 1855.5 No 0 0 1 Yes Yes Yes 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS \/ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet %\./ 1 Slab-On-Grade Edge lnsulatio Foyer 21.42 ft 0 118 ft2 ____ 0 1 0 1/ 2 Slab-On-Grade Edge Insulatio Kitchen 33.92 ft 0 218 ft2 ____ 0 1 0 3 Slab-On-Grade Edge lnsulatio Mudroom 8.58 ft 0 40 ft2 ____ 0 1 0 1 4 Slab-On-Grade Edge lnsulatio Dining Room 8.83 ft 0 190 ft2 ____ 0 1 0 5 Slab-On-Grade Edge lnsulatio Living Room 34.5 ft 0 315 ft2 0 0 1 6 Slab-On-Grade Edge Insulatio Office 32.75 ft 0 115 ft2 ____ 0 0 1 V 7 Slab-On-Grade Edge lnsulatio Bathroom 1 16.5 ft 0 58 ft2 ____ 1 0 0 V 8 Floor over Garage Master Closet ____ ____ 99 ft2 19 0 0 1 ✓ 9 Floor over Garage Master Bath ____ ____ 200 ft2 19 1 0 0 / 10FIoor Over Other Space Master Bedroom ____ ____ 240 ft2 0 0 0 1 11FIoor Over Other Space Bedroom 1 ____ ____ 175 ft2 0 0 0 1 ✓ 12FIoor Over Other Space Bedroom 2 ____ ____ 175 ft2 0 0 0 1 13FIoor Over Other Space Bathroom 2 ____ ____ 85 ft2 0 1 0 0 `1 14FIoor Over Other Space Bedroom 3 ____ ____ 145 ft2 0 0 0 1 15Floor Over Other Space Bathroom 3 ____ ____ 65 ft2 0 1 0 0 16FIoor Over Other Space Bedroom 4 ____ ____ 180 ft2 0 0 0 1 17FIoor Over Other Space Laundry Room ____ ____ 40 ft2 0 1 0 0 18FIoor Over Other Space Hall and Stairs ____ ____ 159 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) Y 1 Hip Metal 1612 ft2 0 ft2 Medium 0.96 No 0.9 No 0 14 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC ✓ 1 Full attic Vented 300 1564 ft2 N N 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type J 1 Under Attic(Vented) Master Closet 30 110 ft2 0.11 Wood 2 Under Attic(Vented) Master Bath 30 210 ft2 0.11 Wood -y- 3 Under Attic(Vented) Master Bedroom 30 220 ft2 0.11 Wood __,,/ 4 Under Attic(Vented) Bedroom 1 30 175 ft2 0.11 Wood ✓/ 5 Under Attic(Vented) Bedroom 2 30 175 ft2 0.11 Wood 6 Under Attic(Vented) Bathroom 2 30 85 ft2 0.11 Wood ✓ 7 Under Attic(Vented) Bedroom 3 30 145 ft2 0.11 Wood ✓ 8 Under Attic(Vented) Bathroom 3 30 65 ft2 0.11 Wood __AL, 9 Under Attic(Vented) Bedroom 4 30 180 ft2 0.11 Wood y 10 Under Attic(Vented) Laundry Room 30 40 ft2 0.11 Wood Y 11 Under Attic(Vented) Hall and Stairs 30 159 ft2 0.11 Wood WALLS / Space Adjacent Cavity Width Height Sheathing Framing Solar Below V # nrnt Tn Wall Type p R-Value Ft In Ft In Area R-Vallle Frartinn Ahanr ( rade% 1r 1 W Exterior Frame-Wood Foyer 19 11 4 10 4 117.1 ft2 0.23 0.75 0 ✓2 N Garage Frame-Wood Foyer 19 10 1 10 4 104.2 ft2 0.23 0.75 0 l'3 W Exterior Frame-Wood Kitchen 19 14 10 4 144.7 ft2 0.23 0.75 0 -4 S Exterior Frame-Wood Kitchen 19 12 6 10 4 129.2 ft2 0.23 0.75 0 ✓5 N Garage Frame-Wood Kitchen 19 7 5 10 4 76.6 ft2 0.23 0.75 0 ■76 N Garage Frame-Wood Mudroom 19 8 7 10 4 88.7 ft2 0.23 0.75 0 °/7 S Exterior Frame-Wood Dining Room 19 8 10 10 4 91.3 ft2 0.23 0.75 0 /8 S Exterior Frame-Wood Living Room 19 13 10 4 134.3 ft2 0.23 0.75 0 7 9 E Exterior Frame-Wood Living Room 19 21 6 10 4 222.2 ft2 0.23 0.75 0 10 S Exterior Frame-Wood Office 19 7 8 10 4 79.2 ft2 0.23 0.75 0 ,\../11 E Exterior Frame-Wood Office 19 15 1 10 4 155.9 ft2 0.23 0.75 0 12 N Exterior Frame-Wood Office 19 10 10 4 103.3 ft2 0.23 0.75 0 l/13 N Exterior Frame-Wood Bathroom 1 19 5 4 10 4 55.1 ft2 0.23 0.75 0 17 14 W Garage Frame-Wood Bathroom 1 19 11 2 10 4 115.4 ft2 0.23 0.75 0 L/ 15 W Exterior Frame-Wood Master Closet 19 11 2 11 8 130.3 ft2 0.23 0.75 0 f 16 N Exterior Frame-Wood Master Closet 19 7 10 11 8 91.4 ft2 0.23 0.75 0 ✓1 17 N Exterior Frame-Wood Master Bath 19 19 11 8 221.7 ft2 0.23 0.75 0 7✓ 18 N Exterior Frame-Wood Master Bedro 19 15 11 8 175.0 ft2 0.23 0.75 0 19 E Exterior Frame-Wood Master Bedro 19 14 7 11 8 170.1 ft2 0.23 0.75 0 20 W Exterior Frame-Wood Bedroom 1 19 14 4 11 8 167.2 ft2 0.23 0.75 0 21 W Exterior Frame-Wood Bedroom 2 19 11 11 8 128.3 ft2 0.23 0.75 0 22 S Exterior Frame-Wood Bedroom 2 19 16 2 11 8 188.6 ft2 0.23 0.75 0 ✓ 23 W Exterior Frame-Wood Bathroom 2 19 1 6 11 8 17.5 ft2 0.23 0.75 0 -724 S Exterior Frame-Wood Bathroom 2 19 8 9 11 8 102.1 ft2 0.23 0.75 0 25 S Exterior Frame-Wood Bedroom 3 19 11 9 11 8 137.1 ft2 0.23 0.75 0 26 S Exterior Frame-Wood Bathroom 3 19 5 6 11 8 64.2 ft2 0.23 0.75 0 -/'27 E Exterior Frame-Wood Bathroom 3 19 11 11 8 128.3 ft2 0.23 0.75 0 /28 E Exterior Frame-Wood Bedroom 4 19 11 6 11 8 134.2 ft2 0.23 0.75 0 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In __Z_ 1 W Wood Foyer Wood .46 3 6 8 20 ft2 _..s L 2 N Wood Mudroom Wood .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening V 1 W 1 Vinyl Low-E Double Yes 0.35 0.27 12.3 ft2 3 ft 0 in 2 ft 3 in Drapes/blinds None ✓ 2 W 1 Vinyl Low-E Double Yes 0.35 0.27 5.0 ft2 3 ft 0 in 2 ft 3 in Drapes/blinds None >� 3 W 3 Vinyl Low-E Double Yes 0.35 0.27 24.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 4 S 7 Vinyl Low-E Double Yes 0.35 0.27 30.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 5 S 8 Vinyl Low-E Double Yes 0.35 0.27 30.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None V 6 E 9 Vinyl Low-E Double Yes 0.35 0.27 40.0 ft2 7 ft 8 in 2 ft 3 in Drapes/blinds None ✓ 7 E 9 Vinyl Low-E Double Yes 0.35 0.27 80.0 ft2 7 ft 8 in 2 ft 3 in Drapes/blinds None -7- 8 S 10 Vinyl Low-E Double Yes 0.35 0.27 12.0 ft2 7 ft 8 in 2 ft 3 in Drapes/blinds None 9 E 11 Vinyl Low-E Double Yes 0.35 0.27 24.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 10 N 12 Vinyl Low-E Double Yes 0.35 0.27 12.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None V 11 N 13 Vinyl Low-E Double Yes 0.35 0.27 6.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 12 W 15 Vinyl Low-E Double Yes 0.35 0.27 36.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 13 N 17 Vinyl Low-E Double Yes 0.35 0.27 16.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 14 N 18 Vinyl Low-E Double Yes 0.35 0.27 36.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 15 E 19 Vinyl Low-E Double Yes 0.35 0.27 24.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 4.0" 16 W 20 Vinyl Low-E Double Yes 0.35 0.27 36.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 17 W 21 Vinyl Low-E Double Yes 0.35 0.27 36.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 18 S 22 Vinyl Low-E Double Yes 0.35 0.27 18.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None ,1 / 19 S 24 Vinyl Low-E Double Yes 0.35 0.27 8.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None 20 S 25 Vinyl Low-E Double Yes 0.35 0.27 18.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None / 21 E 27 Vinyl Low-E Double Yes 0.35 0.27 8.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None ?✓ 22 E 28 Vinyl Low-E Double Yes 0.35 0.27 36.0 ft2 2 ft 6 in 2 ft 3 in Drapes/blinds None GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation V 1 301.8375 ft2 384 ft2 38 ft 10.33 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000035 242.8 13.33 25.07 .0335 .5 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts J 1 Electric Heat Pump Split HSPF:8.2 23.2 kBtu/hr 1 sys#1 2 Electric Heat Pump Split HSPF:8.2 32.8 kBtu/hr 2 sys#2 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts ✓ 1 Central Unit Split SEER: 14 23.4 kBtu/hr 800 cfm 0.75 1 sys#1 2 Central Unit Split SEER: 14 34.6 kBtu/hr 1200 cfm 0.75 2 sys#2 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation ./ 1 Natural Gas Tankless Garage 0.82 1 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return- Air CFM 25 CFM25 HVAC# �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool ✓ 1 Attic 6 261.8 ft Attic 65.45 ft Default Leakage Foyer (Default) (Default) 1 1 ✓ 2 Attic 6 317.4 ft Attic 76.3 ft2 Default Leakage Foyer (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin ]Jan Feb Mar A r Ma X Jun X Jul X Au X Se Oct Nov Dec Heating [X]Jan [X�Feb [Xi Mar [ I Ar f I May f I Jun f I Jul 4 I Aug f I Sep [ i Oct [X1 Nov [X�Dec Venting [[ ]Jan [ Feb [X Mar [X Apr [ May [ Jun [ Jul [ Au [ Sep [X Oct [X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 , FORM•R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 645 Ocean Blvd Permit Number: Atlantic Beach , FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. V 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. o R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers, if installed at the time of the test,shall be fully open. o R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. o R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. o R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls / that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. CJ R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system, including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 FORM*R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ni R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., o R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/:inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies o R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. o R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. o R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. o R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. o R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 ' FORM'R405-2014 MANDATORY REQUIREMENTS - (Continued) o R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. o R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. o R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 4. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. q R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. o R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance • with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. o R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. o R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. I RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. o R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. o R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Indriolo Residence Builder Name: Joe Idriolo Street: 645 Ocean Blvd Permit Office: City,State,Zip: Atlantic Beach, FL,32233 Permit Number: Owner: Joe ldriolo Jurisdiction: Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 3/4/2016 8:28 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 EMS Heat Loss/Heat Gain Calculation Company: Green Engineering Solutions, Customer: Indriolo Residence Inc. Preparer: Ronald Miller CER#960 Address: Phone: 904-400-0624 645 Ocean Blvd. Atlantic Beach, FL 32233 Phone: Date: 3/3/2016 This HVAC load calculation has been performed using sound engineering principles as prescribed by Manual J seventh and eighth abridged editions and ASHRAE Fundamentals. Duct sizing has been performed as prescribed by Manual D. 1. Design Conditions Total conditioned area (sq.ft.) 1054 Indoor Outdoor Temp.Diff. Front of home is facing: Winter 70 34 36 West Summer 75 95 20 2. How would you describe the summer humidity in your area? Very Humid 60 Grains difference 3. How tight is the house? Average-under 1500 Sq. Ft. Winter air change/hr: 1 Summer air change/hr: 0.5 4. Fireplace evaluation : Number: None Tightness: No fireplace 0 5. Number of occupants: l 6. Overhang characteristics (optional) East West S/SE/SW Distance of overhang from 2.25 2.25 2.25 top of window(Ft.) I Length of overhang II 2.5 II 2.5 II 2.5 I Tab 0 . 7. Solar gain through glass Facing Total area Sq.Ft. Type of glass HTM Linear ft. J Unshaded Shaded BTUH N/Shaded 150.06 Trpl or low-E 20 Below OH 150 NE/NW -- Select -- 0 0 South 60 Trpl or low-E 33 60 0 1980 SE/SW -- Select -- 0 0 0 East 24 Trpl or low-E 65.0 24 0 1560 West 41.34 Trpl or low-E 65.0 41 0 2687 Skylight -- Select -- 1 0 Total North and Shaded 150 3001 Total Solar Gain 9228 !Adjust for tinted or reflective window coating No 1 9228 8. Ducts/Pipes !Location: (Radial or spider in attic Attic Temp. Insulation Leakage [ Area 130 R-4 1.24 sealed Q 1054 'Duct gain: 110.233 IlDuct loss: 110.107 I Tab 1 9. Load Calculation Elements of Load Insulation/R-value l Area/lin.ft. U value Heat Loss Heat Gain IGross Wall 1616.65 Glass solar gain 19228 'Glass 1 1Trpl or low-E 1275 0.42 14164 Glass 2 I-- Select-_ I0 (.Skylight 1-- Select -- 0 10 Boors 'Insulated or Storm 140.02 10.4 576 320 Net wails IR-19 1301 0.06 12811 1561 'Ceilings 1 - Select- 10 0 'Floors 1-- Select -- 10 0 !?pen floors" '-- Select -- 10 (0 Slab floors No Insulation 156.5 10.8 14507 10 'Volume of your building or zone(cu. Ft.) 110887.82 7186 1996 'People 300 Appliances 1900 ub 15306 lduct Total LosslGain 12064 19244 3567 'Sensible Load 121308 18873 'Latent Load 3932 'TOTAL BTUH (21308 122805 Summary BTUH Tons Total heating load 21308 Total cooling load 22805 1.9 Tab 2 Room by Room Total Heat Loss 21308 System CFM(cooling) 800 Total Heat Gain 18873 System CFM (heating) 800 III oom name Foyer !Kitchen Mudroom Roomg oom 'Office 'Bathroom 'Gross wall 11221.27 350.39 88.63 91.21 356.39 338.31 170.45 1North windows 120.06 124 6 1NE/NW windows Isouth windows 1 30 30 E/SW windows East windows 124 (West windows 17.34 124 Skylight 1 'Doors 1120.01 120.01 (Net walls 184 326 69 61 1206 1290 164 !Ceiling I 'Floor-crawl I !Floor-open I 'Floor-slab 121.42 33.92 8.58 8.83 34.5 32.75 16.5 'Infiltration 37 124 120 30 150 148 6 'People 1 1 (Appliances 1900 500 500 (Heat loss 12674 12870 1262 1687 7891 3753 1171 'Sensible Heat Gain 12151 3704 1455 1545 6274 14306 1438 'Cooling CFM 91 157 1147 66 1266 183 19 [Heating CFM 11100 11108 1147 1163 11296 11141 1144 1 Tab 5 Air Ducts Sizing Total measured length of ducts 42 Use cooling CFM Total equivalent length of fittings 17.5 Metal ducts used Available static pressure for duct .34 Friction rate .07 CFM No. outlets Outlet CFM Duct diam. Air vel. I Supply trunk I branch I First section off AHU I 800 13.7 780 1 1st reduction 1 branch I 75 5.6 439 I 2nd reduction/branch I 150 7.3 519 1 3rd reduction/branch I 50 4.8 398 I 4th reduction 1 branch I 75 5.6 439 1 5th reduction I branch I 250 8.8 588 (_ Return trunk/branch I First section off AHU 800 13.7 780 1 1st reduction/branch 1 0 1 2nd reduction/branch I 0 1 3rd reduction/branch I 0 4th reduction/branch 0 1 5th reduction/branch 1 0 I Room runs I Foyer 91 1 91 6 459.8 Kitchen 157 1 157 7.4 524.9 Mudroom 19 1 19 3.3 314.2 Dining Room 66 1 66 5.3 425.2 Living Room 266 2 133 7 504.2 Office 183 2 91.5 6 460.4 I Bathroom 1 II 19 II 1 II 19 II 3.3 II 314.2 I Tab 6 Equipment selection as per Manual S BTUH Nom.Tons Total heat loss 21308 Design temp. Outdoor Indoor Total heat gain 22805 1.9 Winter 34 70 Sensible heat gain 18873 Summer 95 75 i Latent heat gain 3932 ID design RH 50%, 63F WB Sensible/total ratio 0.83 Altitude Target cooling TD 19 Predominantly Cool climate Manufacturer's Equipment Specification Equipment manufacturer Model Nu. BTUH output Furnace rig.capacity @ OD design temp. Boiler Total Sensible Latent Heat Bump l mana ASZ14024 23400 18720 4680 AC Evaporator Air handler (Amana IARUF25C 14 TOTAL CAPACITY with altitude correction 0 23400 18720 4680 'Selected equipment size OK OK OK OK Heating Ext.static pressure of CFMooling CFM(rec.) blower III 896 .5 Available static pressure for duct Supplemental heat needed for heat pump !Blower ext.static press. .5 IHP capacity @ 47F 123200 coil pressure drop IIIP capacity @ 17F 13000 filter pressure drop .1 (HP capacity ODDT 18780 register pressure drop .03 IBTUH supplemental heat 12528 grille pressure drop .03 1KW supplemental heat I 1 other Available SP for duct 110.34 Tab 7 • EMS Heat Loss/Heat Gain Calculation , Loan an Green Engineering Solutions, Company: Inc. Customer: Indriolo Residence Preparer: Ronald Miller CER#960 Address: Phone 904-400-0624 645 Ocean Blvd. Atlantic Beach, FL 32233 Phone: Date: 3/3/2016 This HVAC load calculation has been performed using sound engineering principles as prescribed by Manual J seventh and eighth abridged editions and ASHRAE Fundamentals. Duct sizing has been performed as prescribed by Manual D. 1. Design Conditions Total conditioned area(sq.ft.) 1564 Indoor Outdoor Temp.Dff. Front of home is facing: Winter 70 34 36 West Summer 75 95 20 2. How would you describe the summer humidity in your area? Very Humid 60 Grains difference 3. How tight is the house? Average-over 1500 Sq. Ft. Winter air change/hr: 0.7 Summer air change/hr: 0.35 4. Fireplace evaluation : Number: None Tightness: No fireplace 0 5. Number of occupants: 5 6. Overhang characteristics (optional) East West S/SE/SW Distance of overhang from 2.25 2.25 2.25 top of window (Ft.) I Length of overhang II 2.5 II 2.5 II 2.5 I Tab 0 7. Solar gain through glass Facing Total area-Sq.Ft. Type of glass HTM Linear ft. J Unshaded Shaded BTUH N/Shaded 52 Trpl or low-E 20 Below OH 52 lE/1 'W 1 _- Select -- 0 0 South 44 Trpl or low-E 33 44 0 1452 SE/SW -- Select -- 0 0 0 East I 68 Trpl or low-E 65.0 68 0 4420 West 108 Trpl or low-E 65.0 108 0 7020 Skylight -- Select -- 0 I Total North and Shaded I 52 1040 I Total Solar Gain I 13932 'Adjust'for tinted or reflective window coating:! No 1 13932 8. Ducts/Pipes !Location: drunk and branches in attic Attic Temp. I Insulation ! Leakage Area 130 R-6 1 sealed 0 1564 !Duct gain: 110.344 11Duct loss: 110.165 Tab 1 9. Load Calculation Elements of Load Insulation/R-value Area/lin.ft. U-value Heat Loss Heat Gain J !Gross Wall 1856.46 Glass solar gain 13932 lass 1 'Trpl or low-E 1272 10.42 14113 l 'Glass 2 1-- Select -- 10 kylight I-- Select-- 0 10 'Doors 1-- Select -- 10 0 1584 10.06 13422 1901 'I1et walls 1R-19 'Ceilings 1--- Select -- 10 N 'Floors - Select -- 10 10 Open floors IR-19 38 0.055 75 142 [Slab floors I-- Select -- 10 JO 'Volume of your building or zone(cu. Ft.) 118251.88 8432 12342 'People 1 1500 'Appliances 3000 [Sub Total 16043 122717 'Duct Loss/Gain `112640 7811 ISensible Load 18683 30529 'Latent Load 5494 'TOTAL$TUH 18683 136023 Summary BTUH Tons Total heating load 18683 Total cooling load 36023 3 Tab 2 . Room by Room Total Heat Loss 18683 System CFM (cooling) 1200 Total Heat Gain 30529 System CFM (heating) 1200 itt Master aster aster edroom edroom 'Bathroom 'Bedroom athroom edroom Laundry oam name Closet ath edroom 1 2 3 13 Room 'Gross wall 1221.73 1221.73 345.20 167.23 317.07 119.62 137.12 192.56 134.21 North 16 36 windows NE/NW windows South` 18 8 18 windows SE/SVV windows 'East windows 124 8 36 West 36 36 36 windows , li,ht (Doors et wails 186 1206 1285 131 1263 112 119 185 98 0 !Ceiling ; 110 1210 1220 175 175 85 145 165 180 140 (Floor-crawl (Floor-open'' 19 19 IFloor-slab 'Infiltration 136 16 60 36 54 8 18 8 36 0 (People 1 1 1 1 1 'Appliances 500 500 500 500 500 500 Ifleat loss 112445 1421 3940 12264 3562 710 1266 894 12181 0 Sensible Heat 3889 975 5293 4848 6067 627 2274 1089 4795 672 Gain oolin e CFM 153 38 1208 191 1238 125 89 143 188 126 'Heating CFM 157 91 1253 145 1229 146 81 57 140 Io (Room nan a IHall/Stairs 'Gross wall 'North windows INE/NW windows South windows ISE/SW windows 'East windows I 'West windows Skylight IDoors II I Tab 5 INet walls 10 !ceiling 1 159 loor-crawl !Moor-open I !Floor-slab tInfiltration Ito 'People Appliances !Heat loss 10 [Sensible Heat Gain 0 'Cooling CFM (0 !Heating CFM 110 Tab 5 a Air Ducts Sizing Total measured length of ducts 45 Use cooling CFM Total equivalent length of fittings 16.5 Metal ducts used Available static pressure for duct .34 Friction rate .07 CFM No.outlets Outlet CFM Duct diam. Air vet. I Supply trunk/branch 1 First section off AHU 1200 16 861 1st reduction/branch 860 14.1 794 2nd reduction/branch 450 11 678 3rd reduction/branch` 150 7.3 519 4th reduction I branch 0 I 5th reduction/branch I 0 I Return trunk/branch First section off AHU 1200 16 861 1st reduction/branch 860 14.1 794 2nd reduction/branch 450 11 678 3rd reduction/branch; 150 7.3 519 4th reduction/branch 0 5th reduction/branch 0 Room runs Master Closet 153 1 153 7.3 521.7 Master Bath 38 1 38 4.3 371.9 Master Bedroom 208 1 208 8.2 562.1 Bedroom 1 191 1 191 8 550.5 Bedroom 2 238 1 238 8.7 580.8 Bathroom 2 25 1 25 3.7 335.9 Bedroom 3 89 1 89 6 457.3 Bathroom 3 43 1 43 4.5 383.2 Bedroom 4 188 1 188 7.9 548.4 Laundry Room 26 1 26 3.7 339.1 I Hall/Stairs II 0 II 0 II II 0 II I Tab 6 Equipment selection as per Manual S BTUII Nom.Tons Total heat loss 18683 Design temp. Outdoor Indoor Total heat gain 34023 2.8 Winter 34 70 Sensible heat gain 25529 Summer 95 75 Latent heat gain 8494 ID design RH 50%, 63F WB Sensible/total ratio 0.75 Altitude Target cooling TD 21 Predominantly Cool climate Manufacturer's Equipment Specification Equipment Manufacturer Model No. BTUH output Furnace IClg. capacity @ OD design temp. 1 Boiler Total Sensible Latent Heat pump/ mana kSZ14036 34600 25600 9000 Evaporator Air handler lAmana IARUF37D 14 (TOTAL CAPACITY with altitude correction j 0 34600 25600 9000 Selected equipment size I OK OK OK OK Heating Cooling CFM Ext.static pressure of CFM (rec.) blower 1108 .5 Available static pressure for duct Supplemental heat needed for heat pump 'Blower ext.static press. 1.5 (HP capacity @ 47F 32800 1 coil pressure drop 1 OP capacity @ 17F 119000 filter pressure drop .1 OP capacity @ ODDT, 1126820 1' register pressure drop 1.03 IBTUH supplemental heat -8137 I grille pressure drop .03 (KW supplemental heat 1-2 other 1 'Available SP for duct 110.34 Tab 7 49 ,Q EAST/2 -S\• ` LOT 4 g. <)<V ,0. V -,,, / 500°18'24"M 50.051(M) EXISTING FENCE LOT 5 50.021(R) LC z z � ❑ ❑ o ■ ■ ■ ■ O^ — Y O n • b i " ce bbbb i i •W',.',.'s, •,",s,"4:1 — O I ' :VW: iy's!i i,i' $„$.28'-O .,.∎ ,. j...jt %�jdI,Ir N Z O ,�� � i. y y. ,.�.�t i.... - r �..�....j.% I ,■— -.`1 .___ ■1 I 'III .. / I I I I I I I I I I I I I I I I I I■I a %% z_D ■I■■■■■■■■■■■■■■■■■■■■■■■ ■ ■■■■W Lu W ■ RELOCATED ■%41%% % .I ....WINO ■ SHED i'k!ifir4I il ,.. mot �Ir ALL COPING b ■;444; I4;p4IN NEW POOL ■., so • CURBS TO BE q ■;gi�vb�i�b�!I ��i�i�i�i PERVIOUS PAVERS • ■�I�s��I•, ,I�i���•. ■:III ALL COPING 4 • R E its* st.*�h�. ���I��sI' TO BE PERVIOUS j ■��i,i�i� ►%%,,,,„, i■n■■■■■�■■■�■■■■■n■■■■■■■WW,,,,,.I NEW PERVIOUS �a KASI , ert k rs��•c c rt.rvws•rs crcwc c•v r .�c. v'� PAVERS STYLE PAVERS \ 1 riKAVUS,#444 444•CI`%„ d„,,,,S,I. I I I I,, y 4 N■ i thAt attl.�s�I�:�tkka`t:.:.t .I.:.Sss.I.:.u.; , s sti ;$ TBD BY OWNER . ■ :itiii NEW FENCE-STYLE E�i�$$$ L / TO MATCH EXISTING NEW PERVIOUS 4,I,,,,,,,I COQUINA SHELL I • �Itaat, �i�i Ai NEW 3X3 POOL •i Ma EQUIP.PAD li FC m WEST%2 II N ' NEW 3X3 A/C PADS ■ -Z 1 8' 8, o LOT 4 POOL s el , BLOCK 16 EQUIP. CV i dJ -� i A/G y ; EXISTING 2-STORY WOOD I PAD 1 FRAME RESIDENCE w u> ' #645 64l A/C d- cZ 1 I, PAD �] CS LI> ir I- ■ m e m i N W dJ i a � O NEW FENCE W/GATE- J . 0 co STYLE TO MATCH r } 51,-0” Ln EXISTING j ° I a KT PROPERTY LINE •• I s 1 .. ■ �I�I�I�I�`'I.I�FRONT SETBACK IL • iii ii:I:�±:I4 *1 ■ = e # a' NEW FRONT PORCH ., Q/ — I■ _ r-o r- I ���• • ALL COPING d CURBS TO BE �, PERVIOUS PAVERS O m W i X�Q6c r++• NEW PERVIOUS '-f , D D ■a COQUINA SHELL Gc Z O Q_ DRIVEWAY d WALKWAY 1 O (L•• •■ Lt- p- II II 6 I NOO°0°152'H 50.021(M) NOTE: 50.001(P) I.NO WATER RETENTION N /�P c �„4� ��, t NOT EXCEED THE 4005QF OCEAN BO JLEA D 2.GRADE TO SLOPE AWF / ON ALL SIDES FOR DRAII ` ft/� A, s-/6.-A, (SO' RIGHT OF WAY) 0---- .1E)__ 2 NEW SITE PLAN AGE AO.I 1/8” = 1'-0" SITE PLAN NOTES I. IT IS THE RESPONSIBILITY OF THE GENE PERIMETER OF STRUCTURE b FIELD VERI SOFT COMMENCEMENT OF CONSTRUCTION. ` ` . JAA ARCHITECTURE INC. T 2718 ST.JOHN'S AVE. }1' JACKSONVILLE, FL 32205 •"' LIC:AR92749 � a. ;. � t�,,* P:(9041379-5108 . 4:: z E:JOHN @JAAARCMITECTURE.COM A R C H I T E C T U R E I N C City Review Comments _.................................................. Project: Indriolo Residence 02 Submission No.: Date of Issuance: 03.28.2016 Submitted JAA Architecture By: 2716 St. Johns Ave. Jacksonville, Fl 32205 (904) 379-5108 Permit#: B-16-RADD-729 ................................. ............................................ Description: The purpose of this submittal is to provide responses regarding plan review comments. Departments Initial Building 1. Survey: Please provide a legal survey. To be submitted by owner. 2. Shed Setbacks:Setback for detached structures like sheds are 5 feet from side and rear property lines. Please show that the relocated shed meets those requirements. Shed location moved to adhere to 5' rear and side yard setbacks on sheet A0.1 3. Fence Height: Please show the fence height of new portions of fencing. Notes added to new portions of fencing to have a maximum height of 6'. 4. Pool Permit: Please show that the pool is to be permitted separately. Note added to sheet A0.1. r :: . JAA ARCHITECTURE INC. 2716 ST.JOHN'S AVE. JACKSONVILLE, FL 32205 .° LIC:AR92746 A .- ._� P:(9041379-510E1 ,.- E:JOHN@JAAARCMITECTURE.COM A R C H I T E C T U R E I N C City Review Comments .................................................... Project: Indriolo Residence 02 Submission No.: Date of Issuance: 03.28.2016 Submitted JAA Architecture By: 2716 St. Johns Ave. Jacksonville, Fl 32205 (904)379-5108 Permit#: B-16-RADD-729 ................................................................................................................................................................................................................................................................................................................................................................... Description: The purpose of this submittal is to provide responses regarding plan review comments. Departments Initial Building 1. Survey: Please provide a legal survey. To be submitted by owner. 2. Shed Setbacks: Setback for detached structures like sheds are 5 feet from side and rear property lines.Please show that the relocated shed meets those requirements. Shed location moved to adhere to 5'rear and side yard setbacks on sheet A0.1 3. Fence Height: Please show the fence height of new portions of fencing. Notes added to new portions of fencing to have a maximum height of 6'. 4. Pool Permit:Please show that the pool is to be permitted separately. Note added to sheet A0.1. MAP SHOWING BOUNDARY SURVEY OF THE WEST 1 /2 OF LOT 4, DANIEL AND HACKETT'S REPLAT OF BLOCK 16, ATLANTIC BEACH, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 9, PAGE 35, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. 20 10 0 20 40 SCALE IN FEET 1" - 20' LOT 5 FOUND 1/2 IRON 81.50'(R) FOUND 1/2 IRON PIPE(NO ID) N8954'43"E 1.29(M PIPE(NO/D )x• 2 '.1SLfl" �36.� Z A/C C0 n O PAD O' O r h•� Z (A(4 WEST LOTT 14 2 0� EAST 1 /2 I to . , 2.0' BLOCK 1 6 --' LOT 4 CN OC O� 0 a 647 2 A/C IO �PAO ° nT �O PALO � � O .NO O `c >s ^i a r• o 1 19.0' 34.2' �K 0FOUNV 1 IRON oS89.55'555"W 80.89"(M) " FOUND 1/2�av- PIPE '.1.8 3672' 80.83'(R) ROD (NO ID) LOT 1 LOT 2 LOT 3 NOTES: 1.) BEARINGS SHOWN HEREON ARE BASED ON THE EAST RIGHT OF WAY LINE OF OCEAN BOULEVARD BEING N 00V9'32" W AND ARE ED. / 2.)ASSUM THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A TITLE COMMITMENT OR REPORT, THEREFOR THERE MAY BE ADDITIONAL '. MATTERS OF RECORD NOT SHOWN HEREON THAT MAY BE FOUND IN JEFFREY H. WEINERT THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. • 0 REGISTERED LAND SURVEYOR NO. 5748 3.) THE ABOVE CAPTIONED LANDS LIE WITHIN FLOOD INSURANCE NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED RATE MAP, COMMUNITY No. 12031C, PANEL 0409 H, DATED SEAL OF A FLORIDA ICENSED SURVEYOR AND MAPPER 6-03-13. JJEFFREY H. WEINERT P.S.M. H 5014 KINGSMEADOW LANE JACKSONVILLE, FLORIDA 32217 W (904) 509-8562 W.O. NO.: 15-103 SURVEY DATE: 7/01/15 DRAFTED BY: J. WEINERT CHECKED BY: J.H.W. CAD FILE: 15103.DWG FB 142 PG 03