Loading...
920 MAYPORT RD - STUCCO ATTACHMENT TEST Jason Canning, Architect Architecture, Planning,Interiors 1713 Furman Rd. Jacksonville, FL 32217 P: (904) 755-5589 F: (904) 406-7227 jason@'canninoarch.com To: Department of Planning Development Building Inspection Division Re: Response to Field Inspection Comments For: Moto Electric Vehicles 9th Street West Atlantic Beach, Florida 32223 April 29, 2016 In response to a field inspection comment in regards to the pull-out strength of the fasteners, an independent test was conducted in(5)locations. The fastener is a#8 2-3/8" self-tapping screw made by Grabber Construction Products. The locations tested were in the center of the smooth area of the metal panel and not at panel overlaps or with metal stud backing. The test results are as follows: Location 1: 247 Location 2: 166 Location 3: 224 Location 4: 227 Location 5: 208 Based on a fastener pattern of 12"O.C.vertically and horizontally(typical Wind Devil 2 fastening pattern"C"),this exceeds the requirements for the 135 mph wind load. Please contact me if you need further information. Sincerely, f Jason Canning,Architect