1303 BEACH AVE REVISION � .1 a \�� CITY OF ATLANTIC BEACH
rs1 800 Seminole Road
Y� --,:_$,-. . l j Atlantic Beach Florida 32233
{.:..",z, OFFICE COP I Telephone (904) 247-5800
FAX (904) 247-5845
e.,....
/ REVISION REQUEST SHEET
Date: -9 /67/ (O
Received by: Resubmitted:
Permit Number: is ' R gfla3 'J/ n/� 1 _ r
Original Plans Examiner: Project Name: rl/Cl (c:tiS/ Lq 10 r01.4
Project Address: / 30 3 i- life_ , -R3 3
Contractor: /l'� 3 G , IdP; s C on t act N ame:
C,A.� J ack. L-)a �
Contact Phone : 9 o c (_ E qj 5 O ys Contact e Sacle.. C rtc ?Intl)/
Revision / Plan Check / Permit Fee (s) Due: $ $K' �d��s ` �M
_Description of Proposed Revision to Existing Permit: nn
S e ' I
' _arc f (c�c>c c � dote AiAJ . M l � - er - � n-ek) �oier n c cva .,e
tc •_ I i - o2 : . r vi rl s q t. G . 5
Additional Increase in Building Value: $ /1 Ov1c2_ Additional S.F. /I an e
Site Plan Revised: 11 o feed e d Public W / U Approval:
By signing below. I (print name) i C h n Li Q CC—
is inc is e of the proposed changes. affirm that the above revision
/ 14 1 . ���1 � l/
E
Sig attire of Contractor / Agent (Contractor must sign if increase in valuation) Date
/ Office Use Only
Date: 5 -- l9 - / 6 Approved: \ Rejected:
H,..
:
Plan Review Comments: AWAY - 5 2016
i t tiv as 'e iSe w e SP
41\e Sob j
5'q ck (or 4•%. a • 1 1* ,/ .Se. 1 -e_
S 4 - trvc•ivra s h - svb -kted -Air ou-r -i'a -e copi,
Department review required Yes No /�
:uild �.
"Il )--'
r larming 8, Zoning
Tree Administrator
Public Works
Plans Examiner
Public Utilities 5 -J 6
Public Safety
Fire Services Date
Created 8/20/15 Rev. 2
11 - (5 D D 2.3 (-7/
Mark Keister
RE: 314- 066.01 RFI 007 and 008 Responses
April 26, 2016 at 7:50 AM
jack c• r....;,_. , Maiju Stansel , Lenny (Jr. ) McAneny
Daniel Overmyer �vermyer(i>
Jack
If there is only slab adjacent to the fireplace and the column will
not bear on a concrete pier or ledge on the chimney foundation, the column will require a 2' -6"
x 2' - 6" x 1' -4" footing with 3 - #5 each way bottom with 3 - #5 drilled and adhesived into the
chimney foundation or masonry and bearing on or with the chimney foundation see S -5.1 New
Footing Abutting Existing Footing Detail. It is acceptable to make the new footing monolithic
with the garage floor slab provided the footing bears on the chimney footing, is doweled into
the chimney and doweled into the surrounding garage concrete slab with #3 x 2' -4" at 2' -0"
O.C. drilled and adhesived into the existing concrete slab, 6" embedment.
Mark .7. Keister, P.E.
Principal
ATLANTIC ENGINEERING SERVICES
Jacksonville, FL \AI\
904 - 743 -4633
m.keister @aespj.com (http: / /www.aespj.com
From: jack [mailto :jack @mcanenybuilders.com]
Sent: Monday, April 25, 2016 11:40 AM
To: Mark Keister <m.keister @aespj.com >; Maiju Stansel <mstansel @rs- architects.com >;
Lenny McAneny <Iwm @ mcanenybuilders.com>
Cc: Daniel Overmyer <d.overmyer@ aespj.com>
Subject: RE: 314 - 066.01 RFI 007 and 008 Responses
Good morning. RFI 007 on the steel column next to the fireplace when I said it is bearing on
4 " -5" of concrete that is the thickness of the slab in that location.
OFFICE COPY
Jack ware
McAneny Builders
904 - 885 -8458 REVISION
mcanenybuilders.com BP# 15 DO c1-3
DATE 5 / G / /6
SIGNED /7/)
M.
I
AES ENGINEERING
SERV1[Eti
n501 Arlington Espy
building B, suite 201
...skswwille.FL32211 Confirmation of Telephone Conversation
PH. 904 743 4633
'r K 904 725 9295 Andrews — Lambrou
lrxfaespi.corn Date: 05 -05 -16 Project: Residence
rww arspi corn
Time: 7:40 am AES Project No.: 314 - 066.01
[x]
Telephone No.: (x) 904 -885 -8458 Call: Placed [] Received
1, Mark j. Keister, P.E. spoke with Jack Ware
of McAneny Builders regarding Garage concrete slab
Comments:
The replacement concrete slab in the garage should match the new slab at the elevator and shall be a
new 6" concrete slab with 6x6- W2.9xW2.9 WWM on vapor barrier on compacted fill. Where the new
slab connects to existing slab, drill and adhesive #3 x 2' -4" at 2' -0" O.C. 6" embedment. Where the
new slab is placed against the existing garage foundation wall, maintain the the floating slab like the
existing garage slab and do not connect the new slab to the existing foundation wall.
i•
f
mark 3, Keister,,.P.E •O51.1