Loading...
1689 LINKSIDE CT N - HVAC ,S!.�A.l�l� , \s, CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD \E_) ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ri )r -�J131 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-MECH-1102 Job Type: MECHANICAL HVAC ONLY Description: HVAC - 1 AC, 1 AHU, 2.5 TON Estimated Value: $4,000.00 Issue Date: 5/12/2016 Expiration Date: 11/8/2016 PROPERTY ADDRESS: Address: 1689 N LINKSIDE CT RE Number: 172374-6210 PROPERTY OWNER: Name: JARANOWSKI,JOHN & ELIZABETH B, * Address: 1689 N LINKSIDE CT GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN Phone: 904-241-3785 PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $20.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $103.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 1 Co-• nA,ee R -` ( CZ FOB ADDRESS: 16 X 9 L i NA St\ C C-1- `V PERMIT# PROJECT VALUE $ yt ezc3 ARI# y I 0 I c t REQUIRED _Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit D. 5 i Heat: Unit Quantity / BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ■IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) +IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: crmit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any otherlstate or local law regulation construction or the perform�g,of���ruction. 'roperty Owners Name Z0kt J O:.@moo S�l Phone Number Mechanical Company .- - tA� A.-IAtc Office Phono \i ' Fax ;o. Address: 1` (o c- AV-k, \A k-- City��o.c_k�o�w1\c State Zip` r y- J .ieense Holder(Print): W,t kk ,b.,, r"-N,Os,,� 1 State Certification/Registration# 3Qt 2 (0 1 Notarized Signature of License Holder ,�Y",•b• RICHARD TOMPKINS efore me thi I! day of M 20 ( L *f.:: Commission#FF 040399 ...��,a€ Expires July 29,2017 ignature of Notary Public ,Ri„^.1t Boded Theo Troy Fen Imuena 800.385-701f • Job: Project Summary Date: May 10,2016 Entire House By: Aaron Thacker Donovan Heat & Air 315 6th Ave S.JeckAonville Beech,FL 32250 Phony 904-241-3785 Fax;904.241-3745 Email:a aron2>idonevnnec.com Web:www.donovenec.com 'Pro eat Information.. For: John Jaranowski 1585 Linkside Ct N,Atlantic Beach, FL 32233 Notes: Desii e n information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 99 °F d Outside db 39 °°F Inside db 75 °F Inside b 70 F Design TD 31 °F Design TD 24 'F Daily range L Relative humidity 55 Moisture difference 62 gr/Ib II Heating Summary Sensible Cooling Equipment Load Sizing 15577 Btuh Structure 13228 Btuh Ducts Structure 3083 Btuh Ducts 4589 Btuh 954 Btuh Central vent(28 cfm) 739 Btuh H vent(28 cfm) 0 Btuh Blower 0 Btuh Humidification 0 Btuh Piping quip 19614 Btuh Use manufacturer's data n Equipment load Rate/swing multiplier 1.04 Infiltration Equipment sensible load 19298 Btuh MethcJ Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2622 Btuh Fireplaces 1 (Average) Structure 1189 Btuh Heating Cooling Central vent(28 cfm) 1188 Btuh Area (ft~) 1120 1120 Equipment latent load 4999 Btuh Volume (ft3) 11200 11200 Air changes/hour 0.56 0.23 Equipment total load 24297 Btuh Equiv, AVF (cfm) 104 43 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade XR 15 Weathertron Trade XR 15 Weathertron Model 4TWR4030D1 Cord 4TWR4030D1 ARI ref no. 7419158 Coil TEM4A0B30 AR1 ref no. 7419158 14 EER Efficiency 8.5 HSPF Efficiency Heating input Sensible cooling 20300 Btuh 29600 Btuh 47°F Latent cooling 8700 Btuh Temperature raturre eu r ise output 28 °F Total cooling ling 29000 Btuh rise Actual air flow 967 cfm Actual air flow 967 cfm Air flow factor 0,052 cfm/Btuh Air flow factor 0.054 cfm/Btuh thermostat 0 in H2O Static pressure 0 in H2O SpaceStatic pressure Load sensible heat ratio 0.79 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 201 E;-May-11 11:03:31 r}+- wrlghts.afc- RIght•Suite Unwereel 7.1.01 RSU05998 1 03. 1 ACCCC.A C:tDocumants and Settinga\ApMen1My DocumenlalwrIghteo$HVAC\Tempialn\Begus 2.5 Ton.rup Oak.MJ