Loading...
310 4TH ST 16-RAAR-535 ASSESSMENT LETTER AGO Alexander Grace Consulfing, Inc. June 14,2016 Bill Elledge Turnkey Construction 5991 Chester Avenue, Unit 105 Jacksonville, FL 32217 Re: Joist Assessment Letter Regante, Unit 310 4th Street,Atlantic Beach, FL Job Number 15-10-0110 Dear Bill, During construction of the above referenced structure's floor system, several plumbing holes were drilled into existing reinforced joists. Several joists were also notched to allow some existing tongue and groove decking to remain. I have visited the site, assessed the joists for the holes and done supplemental calculations on the notched joists. To summarize, all conditions, as they existed during my site visit on June 13,2016,are acceptable.To elaborate: • The 4" holes: I addressed these holes in previous letter communications. The existing 2x10 joists had to be extended to stretch to a new length.The original permit indicated adding a 2x10xl4' scab to each face of the existing joist, with the ends of the scabs bearing in buckets at the new steel beam. A piece of 2x10 filler was installed between the scabbed pieces.This repair was far beyond what was required, but it was best for construction.We assessed the 4" holes and their effect on the moment of inertia and section modulus. Al the locations of the holes, the joists remain strong enough by a large factor. • The 54"long notch: until yesterday,this problem hadn't been made clear to AGC. In the living room area, where the 2x10 joists were extended as described above,there was an area where the original construction included T&G sheathing being installed. That sheathing was left in place, so the repaired joists were trimmed down 2", essentially making the joists an equivalent depth of(2)2x8 starting at the steel beam and extending 54" into the joist. Analyzing the joist within that 54"inches, the joists are still sufficient for bending and shear. Deflection is not a concern so close to the bearing point. If you have further questions, please don't hesitate to call. �pr�Siin WAYA Htrbp�a, • im: +: OFFICE COPY :amu, O E Geo gftA! REVIEWED FOR CODE COMPLIANCE FL 59328 CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS REVIEWED BY: /?10, DATE: 6- /416 3016Swd,3 Stre•I,Smw201 • Jac' ." B.ecb,R-32250 • 904-241-6010 r• OFFICE COPY STOPS