1482 MARSH VIEW CT HVAC PERMIT 11 SS\ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-MECH-1389 Job Type: MECHANICAL HVAC ONLY Description: HVAC - 1 AC, 1 AHLI, 3 TON Estimated Value: $5,476.00 Issue Date: 6/16/2016 Expiration Date: 12/13/2016 PROPERTY ADDRESS: Address: 1482 MARSH VIEW CT RE Number: 170704-0110 PROPERTY OWNER: Name: SELLERS, DAVID J AND TARA J, Address: 1482 MARSH VIEW CT GENERAL CONTRACTOR INFORMATION: Name: OCEAN STATE HEAT & AIR,INC. Address: 1476 ATLANTIC BLVD QA JAMES GLENN JONES Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $24.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $107.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH AX_ goo Seirdnole Rd Atlantic Beach,FL 32233 CL11(, ph(9045 247-5826 Fax(904)247-5845 [ME . -Nc���1_ OB ADDREss: jqg2 MnT5kVLeL0 OOL4 # 'U PROJECT VaUE$ REQU1RED Air Handling Equipmient Only Air Handling.Unit& Condenser Condenser On 4Ew AIR CONDITIONING & HEATING SYSTEM INSTALLATION- Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTUs Per Unit Seer Rating_ Duct Systems: Total CFM REQUIRED tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit �3 tU),S I q Seer Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM 11KE PREVENTION Fur,Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Quantity (Re4uires 3 sets of plans) Fire Suppression Systems. OUS: IRJE PLACES MISCELLANE Preftfitated.Fireplide Qty— Automobile Ljfts Pas Piping Outlets Boilers I — BTU"s, ElevatorsiTscalators ijLL OTHER GASTIPING Heat FAchanger Quantity of Outlets PUMPS #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks:(gallons) Wells )THER: becomes void if work-does not commence wWm a six month period or worlE issuspended or*abandoned for six months.I hereby certify that I ha provisions -s and ordinmxxs goverping this work will be complied with whoher six us application and know the same to be true mid cwTect_-All ran of lav6 onnancc of constructic "m permit does not give audmxfty to violate the provmops 0 . y other stoc or local law regulation construction orthe perr I r Phone Number 5M -A.q� Toperty Owners Name 4echanical Company ()Ceftn Si ttk- fiPl 4A_y Office Phone fax2�41 V .'o. Address: tNp M I tv J - city StatA- Zi�* ,icense Holder(print): Registration 4M2163—b lolarized Sig Y=e P.=fnseJ56dder NOTARY PUBLIC Befo me this 'T- Li KX-, 20 STATE OF FLOM13A Comm#EE879174 Si lie Expires 3MMiT This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2016. AHRI Certified Reference Number: 7117353 Date: 6/14/2016 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWX8036C1 Indoor Unit Model Number: *AM7AOC36H31 Manufacturer: TRANE Trade/Brand name: TRANE Series name: XL181 Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 36600 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 17.00 Heating Capacity(Btuh) @ 47 F: 32400 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 20800 4 publ:sh,�d iala,unless accompanied wiai aVVAS.wNch indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate,Certified ratings are valid only for models and configurations listed in the directory at TERMS AND CONDITIONS 09, This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; 6, entered into a computer database;or otherwise utilized.in any form or manner or by any means.except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at--- .clickon',- link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No,,which is listed at bottom right. 131103952241967502 (c,12014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: