1889 ATLANTIC BEACH DR - ENERGY SHEETS OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Builder Name: Toll Brothers,Inc. Project Name: Anastasia 3242 Left SW Permit Office: Atlantic Beach Street: 1889 Atlantic Beach Dr.(Lot 56 AB) City,State,Zip: Jacksonville ,FL, Permit Number: • Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(3667.7 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 3414.20 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 253.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2d.N/A R= ft2 4. Number of Bedrooms 4 ` 10.Gelling Types (2635.0 sqft.) Insulation Area = 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2291.00 ft2 ' 3242 b.Under Attic(Vented) R=19.0 344.00 ft2 6. Conditioned floor area above grade(ft2) c.N/A R= ft2 Conditioned floor area below grade(ft') 0 11.Ducts R ft2 Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 242 7. a. U-Factor: sqft.) 1,U=0.333n ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 328.9 a. U-Factor: Dbl, 450.00 SHGC: SHGC=0.30 b. U-Factor: N/A 12.Cooling systems kBtu/hr Efficiency a.Central Unit ft' 18.0 SEER:14.00 SHGC: b.Central Unit 36.0 SEER:14.00 ft2 c. U-Factor: N/A kBtu/hr Efficiency SHGC: 13.Heating systems 18.0 HSPF:8.20 d. U-Factor: N/A ft2 a.Electric Heat Pump 36.0 HSPF:8.20 b.Electric Heat Pump SHGC: Area Weighted Average Overhang Depth: 5.221 ft. 14.Hot water systems Area Weighted Average SHGC: 0.300 a.Natural Gas Tankless •Cap:1 gallons 8. Floor Types (3242.0 sqft.) Insulation Area EF:0.600 a.Slab-On-Grade Edge Insulation R=0.0 2635.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 607.00 ft2 None c.N/A R= ft' 15.Credits Pstat Total Proposed Modified Loads: 74.06 PASS Glass/Floor Area: 0.139 Total Baseline Loads: 81.90 • I hereby certify that the plans and specifications covered by Review of the plans and °�Qil tI L STAr.G tv� this calculation are in compliance with h the Florida Energy specifications covered by this ,;�{ . •;,• " ;-:8$ �`0�'� • - Code. calculation indicates compliance �; y Iii, , ..,_ ii. 3 // / with the Florida EnergyCode. 'df CC+i+, `:, -``i*.fes,,,.0 PREPARED BY: . _' /i.GsL� .- 0 - la- Before construction is completed 4 sa: fin : FORM R405-2014 PROJECT Title: Anastasia 3242 Left SW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3242 Lot# Owner: Toll Brothers,Inc. Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers,Inc. Rotate Angle: 0 Street: 1889 Atlantic Beach Dr. Permit Office: Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Jacksonville , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE V IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range V FL,Jacksonville FL_JACKSONVILLElNT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume , 1 Block/ 2635 • 26350 2 Block2 607 5463 SPACES Number Name Area Volume Kitchen Occupants Bedrooms la,ID Finished Cooled Heated 1 Main 2635 26350 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 607 5463 No 1 1 1 Yes Yes Yes FLOORS # Floor Type • Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet V 1 Slab-On-Grade Edge Insulatio Main 221.1 ft 0 2635 ft2 ---- 0 0 1 V 2 Floor Over Other Space 2nd Floor — ---- 607 ft2 0 0 0 1 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) V 1 Gable or shed Composition shingles 3052 ft2 770 ft2 Medium 0.6 N 0.9 No 0 30.3 ATTIC V # Type Ventilation Vent Ratio(1 In) Area RBS IRCC 1 Full attic Vented 300 2635 ft2 N N I • 4/27/2016 2:03 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 I FORM R405-2014 CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type .____ 1 Under Attic(Vented) Main 38 1807 ft' 0.11 Wood V 2 Under Attic(Vented) 2nd Floor 38 484 ft' 0.11 Wood V/ 3 Under Attic(Vented) 2nd Floor 19 123 ft2 0.11 Wood V 4 Under Attic(Vented) Main 19 221 ft2 0.11 Wood WALLS ` / Adjacent Cavity Width Height Sheathing Framing Solar Below V # Ornt T.o Wall-ype Space R-Value_Et-In__EL-In Area R-Vaiue-Fraction-Absor^Grade%__ ✓ 1 SW Exterior Frame-Wood Main 19 16 10 10 0 168.3 ft' 0 0.23 0.6 0 ✓ 2 SW Exterior Frame-Wood 2nd Floor 19 38 0 9 0 342.0 ft' 0 0.23 0.6 0 1/ 3 SE Exterior Frame-Wood Main 19 80 0 10 0 800.0 ft2 0 0.23 0.6 0 ✓ 4 SE Exterior Frame-Wood 2nd Floor 19 23 3 9 0 209.3 ft2 0 0.23 0.6 0 V, 5 NE Exterior Frame-Wood Main 19 45 0 10 0 450.0 ft2 0 0.23 0.6 0 ✓ 6 NE Exterior Frame-Wood 2nd Floor 19 38 0 9 0 342.0 ft' 0 0.23 0.6 0 J 7 NW Exterior Frame-Wood Main 19 80 0 10 0 800.0 ft' 0 0.23 0.6 0 V 8 NW Exterior Frame-Wood 2nd Floor 19 23 3 9 0 209.3 ft2 0 0.23 0.6 0 ✓ 9 SW Garage Frame-Wood Main 13 28 2 9 0 253.5 ft2 0 0.23 0.01 0 ✓ 10 W Exterior Frame-Wood Main 19 4 8 10 0 46.7 ft' 0 0.23 0.6 0 V 11 S Exterior Frame-Wood Main 19 4 8 10 0 46.7 ft' 0 0.23 0.6 0 , DOORS V # Ornt Door Type Space Storms U-Value Width Height Area -! Ft In Ft In V 1 SW Insulated Main None .54 3 8 24 ft' ✓ 2 SW Wood Maln None .39 2 8 8 21.3 ft' • WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening ✓ 1 SW 1 Vinyl Low-E Double Yes 0.33 0.3 8.0 ft' 6 ft 4 in 1 ft 0 in None Exterior 5 ✓ 2 SW 1 Vinyl Low-E Double Yes 0.33 0.3 18.0 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 ✓ 3 W 10 Vinyl Low-E Double Yes 0.33 0.3 18.0 ft' 1 ft 4 in 1 ft 0 In Drapes/blinds Exterior 5 ✓ 4 S 11 Vinyl Low-E Double Yes 0.33 0.3 18.0 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 V 5 SE 3 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft' 1 ft 0 in 1 ft 4 in None Exterior 5 6 SE 3 Vinyl Low-E Double Yes 0.33 0.3 • 18.0 ft2. 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 ✓ 7 NE 5 Vinyl Low-E Double Yes 0.33 0.3 128.0 ft' 14 ft 8 In 1 ft 0 in None Exterior 5 1 8 NE 5 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 • 9 NE 5 Vinyl Low-E Double Yes 0.33 0.3 20.0 ft' 1 ft 4 in 1 ft 0 in None Exterior 5 ✓ 10 NW 7 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 ✓ 11 SW 2 Vinyl Low-E Double Yes 0.33 0.3 6.0 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 V 12 SE 4 Vinyl Low=E Double Yes 0.33 0.3 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 13 SE 4 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft' 1 ft 4 in 1 ft 0 in None Exterior 5 • V14 NE 6 Vinyl Low-E Double Yes 0.33 0.3 3.0 ft' 9 ft 4 In 1 ft 0 In Drapes/blinds Exterior 5 15 NE 6 Vinyl Low-E Double Yes 0.33 0.3 3.0 ft' 1 ft 4 In 1 ft 0 in None Exterior 5 4!27/2016 2:03 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page§oP 5 1 ' FORM R405-2014 •WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening V 16 NW 8 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft' 1 ft 4 in 1 ft 0 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation ✓ 1 602 ft' 602 ft' 67 ft 9 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000312 2651.1 145.54 273.71 .2955 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts • 1 Electric Heat Pump Split HSPF:8.2 18 kBtu/hr 2 sys#1 ✓ 2 Electric Heat Pump Split HSPF:8.2 36 kBtu/hr 1 sys#2 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Alr Flow SHR Block Ducts V 1 Central Unit Split SEER:14 18 kBtu/hr 540 cfm 0.7 2 sys#1 ✓ 2 Central Unit Split SEER:14 36 kBtu/hr 1080 cfm 0.7 1 sys#2 • HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation _il___ 1 Natural Gas Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF V None None ft DUCTS V # --Supply--- ---Return-- Air CFM 25 CFM25 HVAC# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool V 1 Attic 6 242 ft' Attic 82.225 Default Leakage 2nd Floor (Default) (Default) 1 1 2 Attic 6 328.9 ft Attic 82.225 Default Leakage Attic (Default) (Default) 2 2 4/27/2016 2:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 I FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan [[ Feb [[ ]]Mar [ A r I Ma [X]Jun X]Jul [X]Au [X]Se Oct [ Nov Dec• Heating H Jan [XFeb [X]Mar [ i Apr i Ma [ JunJulAuSeOct [X�Nov X DecVenting [ Jan [[ Feb [[X]]Mar [X]]]A r MayI 1 Jun [ 1 Jul ]Aug ]Sep [X Oct [X Nov Dec • Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) APMM 78 78 78 78 78 78 78 78 80 80 78 78 78 78 78 78 80 78 78 80 80 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 8 78 78 788 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 66 66 Heating(WEH) PM 68 68 66 66 66 68 68 68 68 68 68 68 66 4/27/2016 2:03 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 1 --- --... -- - - .. _ --------. --I FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index,the more efficient the home. 1889 Atlantic Beach Dr. (Lot 56 AB) , Jacksonville , FL, From Plans) 9. Wall Types Insulation Area 1. New construction or existing New( a.Frame-Wood, Exterior R=19.0 3414.20 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 253.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 d.N/A R= ft2 4. Number of Bedrooms 4 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2291.00 ft2 6. Conditioned floor area(ft2) 3242 b.Under Attic(Vented) R=19.0 344.00 ft2 c.N/A R= ft2 7. Windows'* Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.33 450.00 ft2a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 6 328 9 SHGC: SHGC=0.30 b.Sup: Attic,Ret:Attic,AH:Attic S b. Factor: N/A ft2 kBtu/hr Efficiency SHGC: 12.Cooling systems ft2 a.Central Unit 18.0 SEER:14.00 c. U-Factor: N/A b.Central Unit 36.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 18.0 HSPF:8.20 Area Weighted Average Overhang Depth: 5.221 ft. b.Electric Heat Pump 36.0 HSPF:8.20 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems Cap:1 gallons Natural Gas a.Slab-On-Grade Edge Insulation R=0.0 2635.00 ft2 a. EF:0.6 b.Floor Over Other Space R=0.0 607.00 ft2 b. Conservation features c.N/A R= ft2 None 15.Credits - Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building SKr:,., ,,, ., Construction through the above energy saving features which will be installed (or exceeded) os ti.� ,. ;g ,C0.4, in this home before final inspection. Otherwise, a new EPL Display Card will be completed u.,r r based on installed Code comp Iia t f a ures. r~ m1,7•" "" ` Date: )0 J Co `� - -���I e�• '"i - Builder Signature: I ,,,., . �i�� w q Q����hh .fir. City/FL Zip: ,q-1 Ft ,,1, '"`v,,c,,1 Address of New Home: (��q �Q L 1 1091 1 t 1 4,,, oo w V-N *Note: This is not a Building Energy Rating. if your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/27/2016 2:03 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 I I i FORM R405-2014l Florida Department of Business a d Professional and Prescriptive riptie RegulationsMethods Residential Whole Building Perform ADDRESS: 1889 Atlantic Beach Dr.(Lot 56 AB) Permit Number: • Jacksonville ,FL, i 1 MANDATORY REQUIREMENTS See individual code sections rofull details. shallrequirethat an energy performance level(EPL) 401.3 Energy Performance Level(EPL)display card(Mandatory). display card5 .9 completeda Statues certified requirese ilder to be accurate display card to bed correct Included asfore final an ddendumoto each sales contract for both presold and [Section ld residential 9085 Florida ] the ever performance level and efficiencies of components nona led In nbuildings.The EPL official display caverd contains informatione EPLdisplay indicating the Appendix C. installed In a dwelling unit.The demonstrate aomplfance for the that hbuEd(ng.A copy orfthe EPL td splay card can ybe founld In Applder urately reflects the plans and specifications submitted to X R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. - R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be Installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. fied as having an air leakage rate of not • 5 air Testing. Climate Zones 1 and 2,and 3tair�ch chall be anges per hour isted and nClimate Zones 3 through 8.Testing shall be condo ted with changes per (50 Pascals).Where required by the code official,testing shall be conducted by an a blower door at a pressureAwritten of 0.2 inches of the ewreg. be signed by the party ng approved T tstin shall be prform doat any time results creation tof all 1p penetrations of the building thermal envelope.and provided to the code official.Testing During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,Intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond Intends d Infiltration control measures; • 3.Interior doors,if Installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. ,2j R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. lass oors have an air per square e foot L/s/m2),andswl ging doorsnomore than 0hts and i 5 ngfm per square footl (2 6 Us/m2),lInfiltration rate of no more ted according to NFRC 400 or per square foot(1.5 ] AAMAIWDMA/CSA 101/1.S.21A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. ng mal de between Recessed conditioned landtuneonditioneded spaces.All recessed luminaireaires installed in the s shall bei IC-rated and labeled as having an ir leakageshall be sealed to limit r ratenot between E 283 at a more althan es shallf besealedwith a gasket or caulk between with housing and the psf(75 Pa)pressure or ceiling covering. All recessed luminalsystem. ji R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. i R403.2.2 Sealing(Mandatory)Ali ducts,air handlers,and filter boxes and building cavities that form the primary air containmeaccordance nt withpassageways ectionfor distribution he Coystemvshall mmercial Provisionsldered of this code and shall be shown to meet and plenum chambers, ll be duct tightnessed and criteriiasbyIpost-construction with Section C403.2.7.2 or rough-in testing below. fied Duct tightness shall be verified tby FlorSection lda Statuteseto be"substant ally leak frethr an energy eeby a then of theefollow ng:in accordance with Section 553.99,Florida Statutes,or as a thoriz d 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 Inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the alrihandler Is oned floor not Installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9 29 m2)of Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. Page 1 of 3 4/27/2016 2:03 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com i FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) �4 R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. 51 R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be Insulated to a minimum of R-3., ys R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. Pf R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. fif R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'A inches(89 mm)in the hot water distribution line and cold water line located as close as possible • to the storage tank. R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies szc R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. R403.4.4.2 Water heating equipment. Water heating equipment Installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. • ▪ R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ,,,( R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the k" Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air Intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are Integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings In ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3- If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be Insulated to a minimum or R-19,space permitting,or R-10 otherwise. R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. fel/ R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and Indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity Is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 9Y 4/27/2016 2:03 PM Ener Gauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. ry alculation and entering wet adjustedlb and for return s de gains if ther eturnlb temperatue ll be for thindoor duct(s)IsIns alleddIn an i humidity used for the load unconditioned space Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. il R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an Intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system Is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. 0 R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. . 0 R403.8 Snow melt system controls(Mandatory). Snow and Ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. 0 R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. 0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.Att report romIepdt labor or is required to verify procedure compliance.Geothermal swimming pool heat pumps are not to met this standard. 0 R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in • compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. o R403.9.3 Covers. Heated swimming pools and inground permanently Installed spas shall be equipped with a vapor-retardant cover on or I at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. A RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be i high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights • R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. SiJR405.2.1 Performance ONLY. Ceilings shall have minimum Insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. Page 3 of 3 4/27/2016 2:03 PM EnergyGaugee USA-FlaRes2014 -Section R405.4.1 Corn FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Anastasia 3242 Left SW Builder Name: Toll Brothers,Inc. Street: /7 1889 Atlantic Beach Dr.(Lot 56 AB) Permit Office: Atlantic Beach City,State,Zip: Jacksonville ,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 1 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. 7 Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and / framing shall be sealed. / Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside / and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl.space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. 7 Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or / unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled / by insulation that on installation readily conforms to the available cavity spaces. 7//Garage separation Air sealing shall be provided between the garage and conditioned spaces.Recessed lighting Recessed light fixtures installed In the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air / • barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or / air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall beZ. • sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have . / • gasketed doors • 4/27/2016 2:03 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 I I 1 I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Anastasia 3242 Left SW Builder Name: Toll Brothers,Inc. Street: 1889 Atlantic Beach Dr.(Lot 56 AB) Permit Office: Atlantic Beach City,State,Zip: Jacksonville ,FL, Permit Number:Jurisdiction: 261300 Design Location: FL,Jacksonville Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data ELA: HOUSE PRESSURE FLOW: Eq LA: ACH: • ACH(50): — SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 Inches l be ted y an roved test shall bel50 Pascals).Where required by the code signed by the arty conducting the testa providedttothe code official.Testing shall be performed d at any time after crd party.A written reation of all of the ts of the penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if Installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. , A1;' 4i, I hereby certify that the above envelope leakage Where required by the code official, v'�` o1 • S..' performance results demonstrate compliance testing shall be conducted by an • , � approved third party. A written ' '"' _ �' c with Florida Energy Code requirements in co r,•1/i,•• . ,�•j . ��, o accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party conducting the test and provided to .`-D '. r" SIGNATURE: the code official. r, '4, • ... 5R 9 . +� Cop wev. PRINTED NAME: • BUILDING OFFICIAL: DATE: DATE: —_— 4/27/2016 2:03 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Softwar Page 1 of 1. McGowan i Project Summary Job: 56 ABCC Date: 4/27/16 dfoufkm4Afr By: Stephen Barber ,�;fo„ e M,, , (Rest of House) YN,•t a��.. 'l McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey©mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: The Anastasia Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25005 Btuh Structure 20644 Btuh Ducts 3383 Btuh Ducts 4304 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28387 Btuh Use manufacturer's data Y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25514 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average0Structure 3375 Btuh Fireplaces Ducts 754 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2635 2635 Equipment latent load 4129 Btuh Volume(ft3) 26106 26106 Air changes/hour 0.23 0.12 Equipment total load 29643 Btuh Equiv.AVF (cfm) 98 53 Req.total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB036 Cond CH14NB036 AHRI ref Coil FB4CNP036 AHRI ref Efficiency 8.2 HSPF Efficiency 11.7 EER, 14 SEER Heating input Sensible cooling 23800 Btuh Heating output 35200 Btu h @47°F Latent cooling 10200 Btuh Temperature rise 31 °F Total cooling 34000 Btuh Actual air flow 1050 cfm Actual air flow 1050 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Apr-27 11:53:01 wrightsoft` Comfort Builder by Wrightsoft 17.0.03 RSU12270 Page 1 ACh` ...struction\Toll Brothers\Anastasia 3242 Left.rup Calc=MJ8 Front Door faces:SW - McGowan' Project Summary • Job: 56ABCC Date: 4127116 Conatkrrirtg n3Air up By: Stephen Barber arilit McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone:(904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: The Anastasia Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 6922 Btuh Structure 6200 Btuh Ducts 1135 Btuh Ducts 1529 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8057 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12949 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average0Structure 1343 Btuh Fireplaces Ducts 267 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 607 607 Equipment latent load 2311 Btuh Volume(ft3) 6030 6030 Air changes/hour 0.51 0.28 Equipment total load 15260 Btuh Equiv.AVF (cfm) 52 28 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB018 Cond CH14NB018 AHRI ref Coil FB4CNP018 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12040 Btuh Heating output 17200 Btuh @ 47°F Latent cooling 5160 Btuh Temperature rise 30 °F Total cooling 17200 Btuh Actual air flow 525 cfm Actual air flow 600 cfm Air flow factor 0.065 cfm/Btuh Air flow factor 0.078 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Apr-27 11:53:01 wrightsoft Comfort Builder by Wrightsoft 17.0.03 RSU12270 Page 2 ACCO \A ...struction\Toll Brothers 3242 Left.rup Calc=MJ8 Front Door faces:SW rI - First Floor Master Bath Me 7& 10x6 3"FanMaster Bedroom 6" •' 16x16 14x6 14„ 3'Fan 4x8 8„ Iligltlst4"' .1101 aFA — 8x4 •• • t16x16 hers 4x8 10" 4" 2-way 6x12 _ 7. breakfast 6x10ba OA 6" 8x4 Bedroom 2 4" 3"Fan 2-cmy, rix 1. 12x12 12 R" 1 Great Room 14 x 14 6x10 Oo 6" �a O� Reatreat 2-way . 6 x 12 7„ kitchen 14" 6 x 10 ',lair, (a) 24 x 18 6 i (0........1...24d0 .. 16" Pantry It all 1 44" x8 pi 9" lo :at1Y\ y.`, ent 4x8• PM \G •��� 3"Fan 10 x 6 4" 10 x6 rJ ,.r 54. 6' 12x12 8" garage 16" 1 Drning recess --❑ til ill 1'—'''.rt Foyer • I ,lair. 10x 6 6""' J 14x6 Garage 12 x 12 8 10" 10 study 7 Jess \ i .\\.,. ..,e,/ Job#: 56 ABCCScale: 1 : 118 McGowan's Heating & Air Conditioning Performed by Stephen Barber for: Page 1 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 17.0.03 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2016-Apr-27 11:53:29 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey@mcgowansac.com ..-Brothers\Anastasia 3242 Left.rup www.tollbrothers.com smerten@tollbrothersinc.com N Ak up pa 14., pa 3'Fan wic 4 y me8x4 18x18 .ath3 4„ " 14' 12x1 10x6 112x12 6" r 1 J 10• II loft 6 xx 14 = 1111110 11 M ■" 11 hall • 1 8. bonus room 4x8 4- 66.0stairs do Job#: 56 ABCCMcGowan's Heating & Air Conditioning Scale: : 118 Performed by Stephen Barber for: Page 2 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 17.0.03 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2016-Apr-27 11:53:29 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey@mcgowansac.Com ...Brothers\Anastasia 3242 Left.rup www.tollbrothers.com smerten@tollbrothersinc.com Manual S Com liance Re ort Job: 56ABCC MCGO iaj p p Date: 4127116 Muting fiAir 1,.. (Rest of House) By: Stephen Barber Cbrtditiatirtq� McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone:(904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 25514 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 4129 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 29643 Btuh Indoor RH: 50% Estimated airflow: 1050 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB036+FB4CNP036 Actual airflow: 1050 cfm Sensible capacity: 25585 Btuh 100%of load Latent capacity: 4855 Btuh 118%of load Total capacity: 30440 Btuh 103%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 28387 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB036+FB4CNP036 Actual airflow: 1050 cfm Output capacity: 26516 Btuh 93%of load Capacity balance: 27 °F Supplemental heat required: 1872 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1050 cfm Output capacity: 8.3 kW 100%of load Temp. rise: 49 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Apr-27 11:53:01 wrightsoftA Comfort Builder by Wrightsoft 17.0.03 RSU12270 Page 1 .4C ...structlon\Toll Brothers\Anastasia 3242 Left.rup Calc=MJ8 Front Door faces:SW Job: 56 ABCC McGowan Manual S Compliance Report Date: 4/27/16 Heating 4;Air up By: Stephen Barber CwtdilearHrtq` • McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 12949 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 2311 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 15260 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB018+FB4CNP018 Actual airflow: 600 cfm Sensible capacity: 13326 Btuh 103%of load Latent capacity: 2476 Btuh 107%of load Total capacity: 15802 Btuh 104%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 8057 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB018+FB4CNP018 Actual airflow: 525 cfm Capacity balance: 13 °F Output capacity: 13500 Btuh 168%of load Economicpacitybalance:la : 13 °F Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 525 cfm Output capacity: 2.4 kW 100%of load Temp. rise: 12 °F The above equipment was selected in accordance with ACCA Manual S. 2018-Apr-27 11:53:01 `, wrightsoft Comfort Builder by Wrightson 17.0.03 RSU12270 Page 2 AC ...struction\Toll BrothersAAnastasia 3242 Left.rup Calc=MJ8 Front Door faces:SW McGowanDuct System Summary Job: 56 ABCC y • Y Date: 4/27/16 yn»tingBNr By: Stephen Barber Conditioning (Rest of House) McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.365/0.135 in H2O 0.365/0.135 in H2O Lowest friction rate 0.094 in/100ft 0.094 in/100ft Actual air flow 1050 cfm 1050 cfm Total effective length(TEL) 532 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath 2 h 270 10 9 0.186 4.0 Ox 0 VIFx 16.4 180.0 st4 Bed 3 h 2131 79 74 0.177 6.0 Ox 0 VIFx 21.5 185.0 st4 Bedroom 2 c 1424 50 60 0.108 6.0 Ox 0 VIFx 57.0 280.0 st6 Dining c 1907 74 80 0.144 6.0 Ox 0 VIFx 58.3 195.0 st3 Foyer h 2266 84 81 0.147 6.0 Ox 0 VIFx 53.8 195.0 st3 Great Room-B c 2532 91 107 0.123 7.0 Ox 0 VIFx 57.3 240.0 st5 Great Room-C c 2532 91 107 0.125 7.0 Ox 0 VIFx 53.2 240.0 st5 Great Room-D c 2532 91 107 0.106 7.0 Ox 0 VIFx 66.0 280.0 st6 Ldry. h 510 19 19 0.178 5.0 Ox 0 VIFx 25.0 180.0 st4 Master Bath h 2467 91 46 0.094 6.0 Ox 0 VIFx 68.6 320.0 st7 Master Bedroom-A h 3575 132 131 0.096 8.0 Ox 0 VIFx 60.8 320.0 st7 Pantry h 172 6 4 0.147 4.0 Ox 0 VIFx 59.0 190.0 st3 Reatreat c 1321 48 56 0.134 6.0 Ox 0 VIFx 36.7 235.0 st5 bath c 81 2 3 0.108 4.0 Ox 0 VIFx 52.1 285.0 st6 clst-A h 410 15 7 0.094 4.0 Ox 0 VIFx 66.7 320.0 st7 hers h 711 26 14 0.096 4.0 Ox 0 VIFx 65.2 315.0 st7 his c 79 2 3 0.096 4.0 Ox 0 VIFx 59.4 320.0 st7 study c 3390 137 143 0.148 8.0 Ox 0 VIFx 51.9 195.0 st3 • 2016-Apr-27 11:53:01 4-..-... +IA wrightsoft` Comfort Builder by Wrightsoft 17.0.03 RSU12270 Page 1 AC ...struction\Toll Brolhers\Anastasia 3242 Left.rup Calc=MJ8 Front Door faces:SW . Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 301 308 0.144 564 10.0 0 x 0 ViniFlx st2 st7 Peak AVF 267 202 0.094 489 10.0 0 x 0 VinIFIx st6 st6 Peak AVF 410 372 0.094 522 12.0 0 x 0 VinIFIx st5 st5 Peak AVF 641 640 0.094 600 14.0 0 x 0 VinIFIx st4 st4 Peak AVF 749 742 0.094 536 16.0 0 x 0 VinIFIx st2 st2 Peak AVF 1050 1050 0.094 594 18.0 0 x 0 VinIFIx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 317 262 143.6 0.094 907 8.0 Ox 0 VIFx dl rb3 Ox 0 403 453 141.0 0.096 325 16.0 Ox 0 VIFx rt1 rb9 Ox 0 330 335 131.3 0.103 615 10.0 Ox 0 VIFx dl Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 1050 1050 0.094 594 18.0 0 x 0 VinIFIx I 2016-Apr-27 11:53:01 ,v^ I wrightsoft° Comfort Builder by Wrightsoft 17.0.03 RSU12270 Page 2 ltil ...struction\Toll Brothers\Anastasia 3242 Left.rup Calc=MJ8 Front Door faces:SW Job: 56 ABCC McGlowan*s Duct System Summary Date: 56AB CaandiVortAgr 'a up By: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.349/0.151 in H2O 0.349/0.151 in H2O Lowest friction rate 0.199 in/100ft 0.199 in/100ft Actual air flow 525 cfm 600 cfm Total effective length(TEL) 251 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk bath 3 h 685 45 40 0.209 6.0 Ox 0 VIFx 22.0 145.0 st1 bonus room c 3166 187 246 0.207 8.0 Ox 0 VIFx 23.1 145.0 st1 hall-A c 100 4 8 0.212 4.0 Ox 0 VIFx 19.7 145.0 st1 loft-C c 2865 184 222 0.211 8.0 Ox 0 VIFx 25.5 140.0 st1 stairs do-A h 876 57 46 0.199 6.0 Ox 0 VIFx 29.8 145.0 st1 wic4-A h 745 49 38 0.203 4.0 Oxo VIFx 26.5 145.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 525 600 0.199 561 14.0 0 x 0 VinIFIx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb2 Ox 0 525 600 76.0 0.199 561 14.0 Ox 0 VIFx 2016-Apr-27 11:53:01 :` +if- wrightsoft' Comfort Builder by Wrightsoft 17.0.03 RSU12270 Page 3 4 ka ...struction\Toll Brothers\Anastasia 3242 Left.rup Calc=MJ8 Front Door faces:SW