Loading...
708 SELVA LAKES CIR - HVAC , ' '` CITY OF ATLANTIC BEACH A 800 SEMINOLE ROAD si IN` • ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-MECH-1402 Job Type: MECHANICAL HVAC ONLY Description: HVAC - 1 AC, 1 AHU. 3 TON Estimated Value: $4,609.00 Issue Date: 6/17/2016 Expiration Date: 12/14/2016 PROPERTY ADDRESS: Address: 708 SELVA LAKES CIR RE Number: 172027-5836 PROPERTY OWNER: Name: BELLOIT. WHITNEY E Address: 708 SELVA LAKES CIR GENERAL CONTRACTOR INFORMATION: Name: OCEAN STATE HEAT & AIR.INC. Address: 1476 ATLANTIC BLVD QA JAMES GLENN JONES Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $24.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $107.00 PERMIT IS APPROVED ONLY IN ACCORDANCE NI I"1'H ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. lliG/.2k5 - -- MECHANICAL PERMIT APPLICATION • - •• CITY OF ATLANTIC BEACH • •FA> E a . 800 Seminole Rd Atlantic Beach,FL 32233 • 2 11P .. Ph(904)247-5826 Fax(904)247-5845 `� ` _ q-O Z OB ADDRESS: 70 0 . Se_/low � Li•K PERMIT# - PROJECT VALUE$ "4 0 / . i#r757?,-,V5 REQUIRED Air Handling Equipment Only X Air Handling Unit & Condenser Condenser On 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit •• Heat: Unit Quantity - BTU's Per Unit Seer Rating QU1RED Duct Systems: Total CFM - tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM STEM INSTALLATION Air Conditioning: Unit Quantity ( Tons Per Unit ^/1 Heat: Unit Quantity BTU's Per Unit 3'y;CO 0 Seer Rating /6-0 Duct Systems: Total CFM REQUIRED IRE PREVENTION (Requires 3 sets of plans) Fire Sprinkler System Quant Fire Standpipe . Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity uires 3 sets of plans) Fire Suppression Systems, Quantity (Requires 3 sets of plans) 'IRE PLACES. • ,. MISCELLANEOUS: ' . Prefabricated Fireplace Qty ..•; Automobile Lifts Gas Piping Outlets . Boilers BTU's'- Elevators/Escalators • kLL OTHER GAS•PIPING ;- . Heat Etchanger Quantity of Outlets . fps_ #Vented Wall Furnaces - ' Refrigerator Condenser • BTU's #Water Heaters , •.-Solar Collection Systems . • , _ -. .`Tanks'(gallons) • Wells )THER: - ermit becomes void if work does not commence within a six month period or work i%suspended or abandoned for six months.I hereby certify that-1 ha ais application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether spt 31. The permit does not give authority to violate the provviision s of any other state or local law regulation construction or the performance of constructic 'roperty Owners Name W h�i ve/I/O • • Phone Number b /O&2 Mechanical Company Oen:0 M - ;P/97r Office Phone /- Faxagert'/ Address: )'t T"/( C-6/(/S' City /1/..6 State kZi13 .icense Holder(Print): J- G Len i 4!* 4 - . State cation/Registration#olid lotarized Sig ,{ e p, n er NOTARY PUBLIC C Ohe me this lig �. • of 20 �:���+STATE OF FLOR � / 1i8"`t•-""'Comm#EE879174 1 V,, • S i,r i t - of No Public �� Expires 3/2/2017 - - ► . This combination qualifies for a Federal Energy . ,ate Efficiency Tax Credit when placed in service ; t J % 3 , , ,, _ � �;between Feb 17, 2009 and Dec 31, 2016. AHRI Certified Reference Number: 7599415 Date: 6/17/2016 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWR5036G1 Indoor Unit Model Number: TEM6A0C36H31+TDR Manufacturer: TRANE Trade/Brand name: TRANE Series name: XR15 Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: 11 i Cooling Capacity (Btuh): 35800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 iii ; Heating Capacity(Btuh) @ 47 F: 34000 tg i Region IV HSPF Rating (Heating): 9.50 i Heating Capacity(Btuh) @ 17 F: 21400 i I l II E 1, e ( i• t t 'R::iir s rdi<:ate a voluntary rerate of previously published dala,unless accomparied with a WAS.wr ch indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the products}listed on this Certificate and makes no representations,warranties or guarantees as to.and assumes no responsibility for. 1 the products;listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the �.•, directory at • i TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and y 5;. 1111 confidential referent e purposes.The contents of this Certificate may not.in whole or in part,be reproduced;copied;disseminated; • a entered into a computer database:or otherwise utilized,in any form or manner or by any means.except for the user's individual, ,a personal and confidential reference. AIR-CONDITIONING,HEATING #I CERTIFICATE VERIFICATION &RFFRIOERSTION INSTITUTE ,' . q , The information for the model cited on this certificate can be verified at , ,� � ,click on`Verify Certificate'link t and enter the AHRI Ce£tified Reference Number and the date on which the certificate was issued, ,t, which is listed above.and the Certificate No.,which Is listed at bottom right. 1 131106422799789694 .1 ©2014 Air-Conditioning. Heating. and Refrigeration Institute CERTIFICATE NO.: