Loading...
270 6TH ST - SOLAR SYSTEM 1 ♦ r y Jlv4 y ,__ f CITY OF ATLANTIC BEACH J" !1 s) 800 SEMINOLE ROAD 0'1 =" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 iN ELECTRICAL PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-ELEC-1447 Job Type: ELECTRIC ONLY Description: INSTALL SOLAR PV SYSTEM Estimated Value: $400.00 Issue Date: 7/7/2016 Expiration Date: 1/3/2017 PROPERTY ADDRESS: Address: 270 6TH ST RE Number: 172562-0000 PROPERTY OWNER: Name: YEATS, ALEXANDER Address: 270 6TH ST GENERAL CONTRACTOR INFORMATION: Name: BEACON ELECTRICAL CONTRACTORS Address: 1428 CRYSTAL SAND DR SHAWN HEATH Phone: - - FEES: State Elec DBPR Surcharge $2.00 State Elec DCA Surcharge $2.00 Electrical Repairs $35.00 Trade Permit Base Fee $55.00 PLAN CHECK FEES $27.50 Total Payments: $121.50 PERMIT IS APPROVED ONLY IN ACCORDANCE WITII ALI. CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. S.-�,yr City of Atlantic Beach APPLICATION NUMBER JS j l Building Department (To be assigned by the Building Department.) J� A8tla tic Beac RoadIt _ — 4ter'' r! Atlantic Beach, Florida 32233 5445 Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: i City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Z7 CD c S ( D ment review required Yes o ,� . —� _ Buildin V Applicant: —FLU/V T j Q Tng &Zoning • Tree Administrator Project: SoL_FAK P V 1�S'1"F, ctil Public Works Public Utilities - Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: L Approved. ['Denied. (Circle one.) Comments: BUILDING PLANNING &ZONINGn- // Reviewed by: Date: / /' TREE ADMIN. Second Review: Approved as revised. ❑Denie y PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 LILDING PERMIT APPLICATT 'N CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 FILE COPY Office (904) 247-5826 Fax (904) 247-5845 ;,obAddress: Drib Lip ce Permit Number: a -L'/L--L -` /L1y7 Legal Description [F) k of\Is' c )9E. IIc Parcel# i c) 51pa. (X)00Floor Area of Sq.Ft. 'q.Ft Valuation of Work$ t'l5b.( D Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s) (circle one): Commercial a_esidentiaLM If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No Florida Product Approval # CLQ � le.e_is) For multiple products use product approval form \ Describe in detail the type of work to be performed: k(�( �V coke.,-,-1/4- 1-coke.,-,-1/4- 1-Y1 Si-Q l I Property Owner Information: Name: P\ exo, /of \ e..QI B Address: O`-] b L1244-) S-t. City A i i.- >.' . J State R`.Zip372 Phone 71)-2D21 - l-2-)(13 E-Mail or Fax#(Optional) .3 A eats Q nc d(. cr)(Y1 Contractor Information: Company Name: A-1A Qr- e cfac+( OTT-J(-Qualyning Agent: 3, 2f \ )t(t i lC% Address:H>-1 2 `tib Yqd.4 I nif DY)) Ci State F 'Zip (40'lice Phone D'-i-l-ItsQ IO Job Site/Contact Number IN-y(p - 1 jp Fax# Mate Certification/Registratio # V Q.. '7r 1 Architect Name& Phone# Engineer's Name& Phone# Dee R MOlt c.(1 el(0 Fee Simple Title Holder Name and Address NI. A Bonding Company Name and Address j\L. F} Mortgage Lender Name and Address k (4 Application is hereby made to obtain a permit to do the work and installations as indicated I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6)months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work, Plumbing,Signs, Wells,Pools, Furnaces,Boilers, Heaters, Tanks and Air Conditioners,etc WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDINGYOUR.NOTICE OF COMMENCEMENT. ,F.. ``!4;:, VIRGINIA ANNA JADA MY COMMISSION#FF991573 I herebycertify that I have read and examined this a plication and know the same to be true and correct. All pro isie , 'aws af�X6Hd&&hdAt gizV (ng this type ofworkwill be complied with whether speci ted herein or not. The granting of a permit does not presu &ola3 itib uthoroa gid incel me provisions of any other federal,state, or local law regulating construction or the performance of construction. Signature of Owner /,g,��• Signature of Contractor // ----- Print Name [e y,e,,•,-`<S--e_4- 111 e. Print Name ------/-7TC42!,C_th 5 • ,""''Day o sobscfibe before . 0 I V; this me Sworn Dayf .subscribed s1W(\-Q- W(\- -before me _ ., ,20 �G ii-I^1 C , ` - tit a,' r Lc � " �c Ui/n..viio a J� Notary ' •lic w .�� ' ' ' ' ION#FF991 3 No ubIic � ': '' '?o.Rr EXPIRES May 11,2020 (407)398-0153 F)o/ballolarySatme.com Revised 01.26.10 ECTRICAL PERMIT APPLICATION FILE COPY CITY OF ATLANTIC BEACH 0 800 Seminole Rd, Atlantic Beach, FL 32233 • Ph(904) 247-5826 Fax (904) 247-5845 ¶ —` .( 447 JOB ADDRESS: @'1i7 tp ce f " hkkan -eagath FL, ?j22 3 PERMIT #t JEA INFORMATION REQUIRED ON ALL PERMITS aOb AMPS cq4C) VOLTS3 PHASE VALUE OF WORK$ 14.co NEW SERVICE ❑ Overhead ❑ Underground ❑1 Underground up Pole Residential(Main) Service 0-100 amps 101-150amps 151-200amps amps #of Meters Commercial(Main)Service 0-100 amps 101-150amps 151-200amps amps CT Service amps Conductor Type Size Multi-Family(Main)Service 0-100 amps 101-150amps 151-200amps amps #of Unit Meters Temporary Pole amps SERVICE UPGRADE amps CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) 100 amps 150amps 200amps amps CT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS Swimming Pool Sign Smoke Detectors_Qty Transformers KVA Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans & Fire Alarm Checklist) Qty volts/amps VALUE OF WORK$ REPAIRS/MISCELLANEOUS ReplaceBuurnt/Damaged Meter Can Safety Inspection Panel Change OH to UG )ether: C3Okek( v CjlAs 'P.(Y1 1.•11S-kOQ1 t Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. AI Property Owners Name .,a401- fir Phone Number r 7a-3a L— l 3"1n 3 Electrical Company .E( c k 'i CC0.1 Cbik.cc thi' ,Tne._, Office Phone-339.-5.SW Fax Co. Address:l3'1)1AUQ.1 9ikci'tN0 pd. Ste.IO7-sNo City-5Qa5D(1Uc`le_ State (_.Zip 2 1B License Holder (Print):— , State Certification/Registration# Notarized Signature of License Holder ' S5 A Sworn and subscribed before me this 1G day of JUJU_ 20 i i.p ;y�✓"'"�;: VIRGINIA ANNA JADA =' •'E MY COMMISSION#FF991573 a EXPIRES May 11,2020 .07)396-0153 Flaida$ot.ryS.,nq.co,ll ELECTRICAL PERMIT APPLICATIO LI CITY OF ATLANTIC BEACH Pe'," t 800 Seminole Rd, Atlantic Beach, FL 32233 FILE CC( r-� hPh (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: D ! V � -c et-, 1"mak rvj C fin- t t. a PERMIT # Signature of Notary Public 'V AA ae1cZ , -------------- 460 4 W �., Z1-1 JJ L^` W ^W c 1_ I , W FILE COPY N N < N N N (B c4 ': v ._ o J 4. N o o � CC e x N C NI M• O — M N = Q1 CD " v a) r� r co 0 a.�, �" r:. ase y .. o O 1 ,e: . N • ■ • 4%, i V Ca 4.4 E cu J Ii {4 ., '/ LL- At" °• y +"+r '`'+". fir•' oVIII 0 0 i1 c a REVIEWED FOR CODE COMPLIANCE O CITY OF ATLANTIC BEACHQ v SEE PERMITS FOR ADDITIONAL N N REQUIREMENTS AND CONDITIONS c! %= rt REVIEWED BY: DATE: 7 / '�G Lo Li)O O VI I\ —______ N • • / M . O O 0 u /��/�" O cD O N M v u 2 N , t0N }' I I i +,,; O 7 0Zf Vv O N 41 CU t >- a_ on U Lt.) C N ` " N u iJ in i •--� .. Y v, c op to ..Y v0- 7 O V) y ,It � 0O v �_ C� U ccX C C Z m CC� �n t 0 4! fV C 0 o o G N m 0 Q Q Q Q r'_-'!% .�lr G cC LL /n In co V iiU BUILDER PROJECT REPORT VFRSION. JUN 14,2016.06:35 PM PROJECT TITLE: 8.55 KW RESIDENTIAL PROJECT ID: 222C8FF4 Name: Yeats Residence Designed by None Address: 270 6th Street SOLARMOUNT City,State: Atlantic Beach,FL,32233 30-280 Watt Panels Module: Suniva OPT280-60-4 35mm 531 Sq Ft. 280 Watts 8.4 kWs INSTALLATION AND DESIGN PLAN LAYOUT WORKSPACE 1 2 3 4 5 6 1 238.1 2 238.1 Array vertical dimension:130.7 Array horizontal dimension:238.1 Row Modules Zone Rail Type Splices Roof Attachments 6 zo"e 1 SM RAIL 240"MILL 320240M I$101 (2) 0 12 2 6 SM RAIL 240"MILL I 320240M I$101 (2) 0 12 Maximum Rail Span(Zone 11: 105.00" Selected Rail Span: 48.00" Maximum Rail Cantilever: 16.00" Module Orientation: Portrait Rail Direction: EW `Zone 2 and 3 Rail Spans must be independently verified • _____._._______. LAYOUT WORKSPACE 2 1 2 3 4 5 6 7 8 1 1 355.E 2 355.6 Array vertical dimension:130.7 Array horizontal dimension:355.8 Row Modules Zone Rail Type Splices Roof Attachments SM RAIL 168"MILL I 320168M I$70(2) 1 9 zone SM RAIL 240"MILL 1320240M I$101 (2) 2 16 SM RAIL 168"MILL I 320168M I$70(2) 2 9 Zone 1 SM RAIL 240"MILL 1320240M I$101 (2) 2 16 Maximum Rail Span(Zone 1"): 105.00" Selected Rail Span: 48.00" Maximum Rail Cantilever: 16.00" Module Orientation: Portrait Rail Direction: EW 'Zone 2 and 3 Rail Spans must be independently verified 2111 U-BUILDER PROJECT REPORT VERSION:1.2 13 JUN 14,2016,06:35 PM PROJECT TITLE: 8.55 KW RESIDENTIAL PROJECT ID: 222C8FF4 Name: Yeats Residence Designed by None Address: 270 6th Street SOLARMOUNT City,State: Atlantic Beach,FL,32233 30-280 Watt Panels Module: Suniva OPT280-60-4 35mm 531 Sq Ft. 280 Watts 8.4 kWs ENGINEERING REPORT Plan review Inspection Product: SOLARMOUNT Loads Used for Design Module Manufacturer: Suniva -Building Code: ASCE 7-10 Model: OPT280-60-4 35mm -Wind Speed: 125 mph Module Watts: 280 watts -Ground Snow Load: 0 psf Module Length: 65.35" -Seismic(Ss): 0.11 Module Width: 38.98" -Wind Exposure: C Module Thickness: 1.38" Loads Determined by Zip Expansion Joints: Every 40' -City,State: Atlantic Beach,FL Rails Direction: EW -Wind Speed: 125 mph Building Height: 30 ft. -Ground Snow Load: 0 psf Roof Type: Shingle Total Weight: 1185.00 lbs r 0 "4111► WORKSPACE 1 Roof Point Load Up: _198 lbs Maximum Rail Span(Zone 1): Roof Point Load Down: 159 lbs Selected Rail Span: Maximum Rail Cantilever: 16.00" Total Number of Modules: 12 Roof Pitch: 6:12 Total KW: 3.4 KW Rows/Columns: 2/6(no gaps) NS Dimension: -10.9 ft EW Dimension: -19.8 ft 1,11lnPv CDA.C',F ' Roof Point Load Up: -198 lbs Maximum Rail Span(Zone 1): Roof Point Load Down: 159 lbs Selected Rail Span: Maximum Rail Cantilever: 16.00" Total Number of Modules: 18 Roof Pitch: 6:12 Total KW: 5.0 KW Rows/Columns: 2/9(no gaps) NS Dimension: -10.9 ft EW Dimension: -29.7 ft z A.-n.r ULO IC RI- (-) r LL W m N N 4 N Ce ce J ` QN O O ,5O � N Ni CCC N o .- m 2 �"+ m - V ` N a •. - .414.04111114.... , = N 0 • - • N ••+ a • al „5,6Z a • •• Iz • LI) 1111 .• , Lr~• y m C CO Ni 0 — + + CD CL -I-, ccU 4-; • •• (NI 1 CT3 CU Irl W Ce O 1-r) r O O a vi O03 H " O M° VD N_ N M u u in Q .Ni E •• H O 7 o2S u O� N N ca vlL a c > v Ln N L N a — ..• 7 O is) U •t L_ O E r° W C 110 u .u-cu N c a C U > X i C Z m `� ''',...,j v p r0 > v = ra m G O O 2 vv) az 0 Q Q Q Q 7 cL rr C to N M ) t't2" Se . . .r ' i, a� r: 2,•••' , / t , Enphase' Microinverters Enphase M250 n b 6 ti 4 Thenphase- M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the M250. the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety. and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage Cable, the Envoy Communications Gateway'', and Enlighten . Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIABLE -Optimized for higher-power - No GEC needed for microinverter -4th-generatior product modules - No DC design or string calculation - More than 1 million hours of testing - Maximizes energy production required and 3 million units shipped - Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25 dust, and debris Cable years �e y enphkase c us Enphase°M250 Microinverter/I DATA INPUT DATA(DC) M250-60-2LL-S22/S23/S24 Recommended input power(STC) 210-300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A Max input current 9.8 A OUTPUT DATA(AC) 0208 VAC 7240 VAC Peak output power 250 W 250 W Rated(continuous)output power 240 W 240 W Nominal output current 1.15 A(A rrrts at nominal duration) 1.0 A(A rms at nominal duration) Nominal voltage/range 208 V!183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range' 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 24(three phase) 16(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC 96.5% —� CEC weighted efficiency,208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted,reference EN50530) 99.4 % Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 2.0 kg Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547,FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, enphase visit enphase.cotr; � c N E it G Y C 2013 Enphase Energy.All rghts reserved.Al trademarks or brands s n this document are registered by thew-espective owner. 1.1 W o v TpT my T G ^xy cy 2 A — 1 / 2II .I ._ Uf illi:.. 0 ; ill / °2F.r £� .s a st _� g x 1, _ 1 2 r Wei n$ d 4 ;_ , � 1 1 / —` 'imams 40111111111101111111 • k 1101001111110a a n I: 1000101111 100010111 mew AMMONS -U■li... — 11111111111111111111 �aU$s11S11 • 827 0.. W ! /1 r gi / 02§ / .. I � _ A Ai S / Y 0 A- x c 1 NAm Fx . E; Zz3 m 2 D S rn _ a — 0 • koN Suniva SUNIVA OPTIMUS- SERIES MONOCRYSTALLIHESOLAR MODULES OPT SERIES:OPT 60 CELL MODULES(BLACK FRAME) Optimus modules are known for their superior quality and long-term reliability.These high-powered modules ENGINEERING EXCELLENCE consist of Suniva's premium ARTisun'Select cell technology • Built exclusively with Suniva's premium ARTisun and are designed and manufactured in the U.S.A.and North Select cells,providing one of the highest power America using our pioneering ion implantation technology. outputs per square meter at an affordable price Suniva's high power-density Optimus modules provide ■ The leading US-born.US-operated crystalline excellent performance and value. silicon cell and module manufacturer,spun out of Georgia Tech's University Center of Excellence >s in Photovoltaics;one of only two such research FEATURES centers in the U.S. f • Utilizes our premier American-made cell ■ Suniva's state-of-the art manufacturing and module technology,ARTisun Select lab facilities feature the most advanced equipment and technology • Superior performance and reliability:enhanced stress tests conducted at Fraunhofer ISE QUALITY & RELIABILITY • Module families ranging from 275-285\V ■ Suniva Optimus modules are manufactured and warranted to our specifications assuring consistent • Marine grade aluminum frame high performance and high quality with hard anodization or powder coating • Rigorous in-house quality management tests beyond standard UL and IEC standards • Certified PID-free by PV Evolution Labs(PVEL) • Performance longevity with advanced • Made in North America polymer backsheet • UL1703 listed Type 2 PV module • Qualifies for Ex-Im Financing • Passed the most stringent salt spray test • 1000 'CI, based on IEC 61701 Passed enhanced stress tests based on IEC 61215 • 25 year linear power warranty; • conducted at Fraunhofer ISE' 10 year product warranty • PAN files are independently validated CERTIFICATIONS MANUFACTURED N1r i ' $ ORIEL Georgia & Michigan www.suniva.com V7. v 0 J v csi CLOD 0 r_ = N Q - N i :; O r+ r• 0 2 a � CZ ' - a ZN 40a O F_Q L V J •— (./1 c f Z wLn z Ln -o ' L_ N ro O > i.N CU t CO j� O mz •/%::% A�1 >, 1 t CU M . l - w r l r0 Q1 O L cr .4 r m p c: -CI Z A 0 s i 1111::°4 S" 0 IX i , IX L'Z < , . I 1 - DN. ■.■ . - 111111 I- CDs 4.1 C7 Z c 7. in IU 1 151) 0 R 4L a, as 1 i C ! 1 w Ii I Z ,o E a, 0 Z p p f \ L LA 4, s �4•1 X II I Z as p j W I I a' ca s I IL +'•LL 3 v) am TA CD •L. 4, L C LL L ( t11 I j Z •N 0 Z L s II %A., 11 c ill a ca ca p0 , t I,I C `*' .0Q ca c J to O (5 ,. . i LL ++ LL �1 , V p CO / 1 ' . ` ' •3 I � L d LL ' LL 3 O c H s s Z ++ I s m D al IR L f �' c 1 Z � � Lu1I , , / cu y � , J � 1 V It iti1 , cs _, •• Q e_ N M F- Q. a. O. a) cu a) Z N V) N C O (0 O -.0 C 4-, -o (0 C E u O >, +J C (0 (0 C a) u 0 E O u u (0 I Z � Q \ IX Q -C N N 1 SOLARMOUNT Technical Datasheets :I:U N I RAC SOLARMOUNT Technical Datasheet Pub 130817 SOLARMOUNT Module Connection Hardware 1 Bottom Up Module Clip 1 Mid Clamp 2 End Clamp 2 SOLARMOUNT Beam Connection Hardware 3 L-Foot 3 SOLARMOUNT Beams 4 SOLARMOUNT Module Connection Hardware SOLARMOUNT Bottom Up Module Clip Part No. 302000C Washer • Bottom Up Clip material: One of the following extruded aluminum Bottom Nut (hidden..s,e alloys: 6005-T5, 6105-T5, 6061-T6 1 Up Clip no , • Ultimate tensile: 38ksi, Yield: 35 ksi * • Finish: Clear Anodized /.‘4 • Bottom Up Clip weight: —0.031 lbs (14g) Beam % Bolt • Allowable and design loads are valid when components are \ assembled with SOLARMOUNT series beams according to ii ---.. .... , _. authorized UNIRAC documents • Assemble with one 1/4"-20 ASTM F593 bolt, one 1/4"-20 ASTM F594 serrated flange nut, and one 1/4"flat washer \ • Use anti-seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- - party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, lbs(N) lbs(N) FS lbs (N) m �- Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662 YTransverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441 0-X 0 Sliding,Z± 66(292) 27(119) 2.44 41 (181) 0.619 Dimensions specified in inches unless noted 111 r 1 SOLARMOUNT Technical Datasheets ::: UNI RAC SOLARMOUNT Beam Connection Hardware SOLARMOUNT L-Foot Part No. 304000C, 304000D • L-Foot material: One of the following extruded aluminum alloys:6005- T5, 6105-T5, 6061-16 • Ultimate tensile: 38ksi,Yield: 35 ksi �� • Finish: Clear or Dark Anodized -.: • L-Foot weight: 0.215 lbs(98g) • Allowable and design loads are valid when components are Bea r ...410011assembled with SOLARMOUNT series beams according to authorized / Bolt UNIRAC documents �'' L-Foot • For the beam to L-Foot connection: •Assemble with one ASTM F593%"-16 hex head screw and one • Oerrate• '• ASTM F594'/8"serrated flange nut Flange N •Use anti-seize and tighten to 30 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory NOTE: Loads are given for the L-Foot to beam connection only; be X sure to check load limits for standoff, lag screw, or other attachment method ,oi Applied Load Average Safety Design Resistance 3%SLOT FOR Direction Ultimate Allowable Load Factor, Load Factor, `."ARDWAR! lbs(N) lbs(N) FS lbs(N) m :o: - Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615 Traverse,X± 486(2162) 213(949) 2.28 323(1436) 0.664 r . SOLARMOUNT Technical Datasheets U N I RAC SOLARMOUNT Beams Part No. 310132C, 310132C-B, 310168C, 310168C-B, 310168D 310208C, 310208C-B, 310240C, 310240C-B, 310240D, 410144M, 410168M, 410204M, 410240M Properties Units SOLARMOUNT SOLARMOUNT HD Beam Height in 2.5 3.0 Approximate Weight(per linear ft) plf 0.811 1.271 Total Cross Sectional Area in2 0.676 1.059 Section Modulus(X-Axis) in3 0.353 0.898 Section Modulus(Y-Axis) in3 0.113 0.221 Moment of Inertia(X-Axis) in° 0.464 1.450 Moment of Inertia(Y-Axis) in° 0.044 0.267 Radius of Gyration(X-Axis) in 0.289 1.170 Radius of Gyration(Y-Axis) in 0.254 0.502 'Rails are extruded using these aluminum alloys: 6005-T5, 6105-T5, 6061-T6 I SLOT FOR T-BOLT OR 1.728 1/4" HEX HEAD SCREW SLOT FOR T-BOLT OR /a"HEX HEAD SCREW 2X SLOT FOR 1 SLOT FOR BOTTOM CUP al 2.500 BOTTOM CUP T ifiAr 3.000 N1.3316 SLOT FOR !Li ' SLOT FOR 1.3853/3" HEX BOLTLim i 3e " HEX BOLT 1 1 .387 .750 L 1.207 Y Y 1.875 A A ►X ►X SOLARMOUNT Beam SOLARMOUNT HD Beam Dimensions specified in inches unless noted 4 r R SOLARMOUNT Technical Datasheets ::' UNI RAC SOLARMOUNT Mid Clamp Part No.302101C, 302101D.302103C, 302104D. 3021050. 302106D • Mid clamp material: One of the following extruded aluminum \ ra - • \� Bolt alloys: 6005-T5, 6105-T5, 6061-T6 Mld 1�1a •e N _ Camp �„ • Ultimate tensile: 38ksi, Yield: 35 ksi ~ • Finish: Clear or Dark Anodized �. • Mid clamp weight: 0.050 lbs(23g) ` \ -.. • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents 1;114 • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SOLARMOUNT series beam to retain a module in the direction indicated • N • Assemble mid clamp with one Unirac%"-20 T-bolt and one'/4'-20 ASTM F594 serrated flange nut Use anti seize and tighten to 10 ftlbs of torque Beam • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory • Applied Load Average Allowable Safety Design Resistance 1.00 DISTANCE - - Direction Ultimate Load Factor, Load Factor, BETWEEN MoouLEs lbs(N) lbs(N) FS lbs(N) m Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667 iI � - - Transverse,Z± 520(2313) 229(1017) 2.27 346(1539) 0.665 Sliding, X± 1194(5312) 490(2179) 2.44 741 (3295) 0.620 ►X Dimensions specified in inches unless noted SOLARMOUNT End Clamp Part No.302001C,302002C,302002D,302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011C,302012C • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 i� :oft • Ultimate tensile: 38ksi, Yield: 35 ksi �%iit • Finish: Clear or Dark Anodized . __->"-------:_..---3\ • End clamp weight: varies based on height: —0.058 lbs (26g) End Clamp • Allowable and design loads are valid when components are rrate• IP° / assembled according to authorized UNIRAC documents Flange Nut • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SOLARMOUNT series beam to retain a module in the direction indicated • Assemble with one Unirac 1/4"-20 T-bolt and one'/4'-20 ASTM F594 i serrated flange nut �i�Bea `x111': • Use anti-seize and tighten to 10 ft-lbs of torque \ r, • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- Y ,4 party test results from an IAS accredited laboratory A • Modules must be installed at least 1.5 in from either end of a beam ►X I.s Applied Load Average Allowable Safety Design Resistance MINIMUM' Direction Ultimate Load Factor, Loads Factor, ' -- lbs(N) lbs(N) FS lbs(N) 0 HEIGHT --_I VARIES TH• S Tension,Y+ 1321 (5876) 529(2352) 2.50 800(3557) 0.605 MUOIN.E THICKNESS Transverse,Z± 63(279) 14(61) 4.58 21 (92) 0.330 Sliding,X± 142(630) 52(231) 2.72 79(349) 0.555 Dimensions specified in inches unless noted zc (f) •� r- > n DT O zo „ o D o � z �• 1 I N # �` 13{ . . i I \ =1 = ." — 1 \ \. m . 4 ' -\I f ' , i ; a cC cr l......i 1, • li 1 al re'T gi i I I jvow O . ,.,. fe... i ') ' f I A M CD O 1 ! t10PAJI I%, i t. i j rt. CD �' e'' p 771 1 ['I." 0. � {1l a I O A UJ N F+t o su r m r `= aro=• = aI o o1. v CM3. °1 r, r* o , 3 s ,-. o rt m D m * M ro _ mi — ro r. C. ID o c ^ rp 1+ 3 :° ? -rj -o CU 0 n < O ro a 7 ro a I -0 5 ssC *• m Z ( -I 3 * o C g -1 • h c _ O � zr -.r -p O -p Cu r+ -1 • .f v ' g v + '^ v 7• s -, -I N ,-* • -z s CDq cnv _0 � OOOQ Cr+ 2- v O � n' w' R (D c a) c O_ '� p _ cu-, Q 0 • N' O 0 .-.. no - '+ D N c n 7- O (CD c C J C- O i N • 1�� c �. 'l, o Cl N Q (D CO • r�r c D v0 , -, rt C -. O0 in' .�+ (O p Or+ (D O -8 D v ck ,+ c .- -n O O_ n n D p r+• - cD Z c o v o 0 o cQ C �' (ND vpi '^ 3 O. O_ O y 0 N ' O O (� D (D5. 3- rte+ Lv 3 O N N �-, o •* (D (Q c▪ • o C (0 Z z (D D S �' -h (D O_ (D 0 - R. O < n + .-I. -0 O �, O n v 0 r+ 3 D p 3 ' o n N (DD v Z O v --� v v + C e O_ v, n N v -4 a) v CD 3 D ,-/' `< O CD m 7 70 Cr CO (,12 (D O_ 0 D v O� v rN+ v C "_ p 7 C (Q o C `< 3 O O (D VI N (D 8O O _ (D O_ O_ Q_ `� • v �. (D .-1. n {(D , '+ O < cn CO (D D' o O_ p r* . CU + _ , O O_ < O D D- (D r+ S p'-p O_ CDD (D S vi O D- (D o v ,+ p CO -, E z O (D v 1 Ni 00 O y -, K C O O (p -n : cc CT �' v)• Oy N•.� 0 v co nc (D a) D m 3 CO CO p Ca_ O N Z`� � O Q O S W CO C CD - (DV (D M D o < o o C1 �, S T 1,+ 7 o v) Z Q D -i CTIm (D O CD en •(D < ,•+ (D CD to •-(‘ o (D cD O_ LIT � CO n 0- C 0 O- ,i• (D O_ ,+ v v -0 D (0 O_ ...� G,1 - OPTIMUS SERIES: OPT 60 CELL MODULES •. i ELECTRICAL DATA(NOMINAL) The rate). ..,ay only v r 0y a.-2.5'Aic and a:'Other eiectr,-^a?: •A•rete.,c s e r v 1 Model Number OPT275 OPT280 OPT285 v A 60-4-180 60-4-1B0 60-4-180 4Power Classification(Pmax) 275 W 280 W 285 W ° 4w•°•+Mw 1 Module Efficiency(%) 16.73% 17.04% 17 34°, Voltage at Max.PowerPoint(Vmp) 32.0 V 32.1 V 32.2 V b} Current at Max.Power Point(Imp) 8.59 A 8.72 A 8.84 A r 1 • '� Open Circuit Voltage(Voc) 39.1 V 39.2 V 39.2 V Short Circuit Current(lac) 9.34 A 9.47 A 9.61 A The etectncar data cooly to standard test conaitons t$TC1:Irradiance of 1000 Wirt'with AM 1.5 spectra at 25-C. CHARACTERISTIC DATA Type of Solar Cell j High-efficiency ARTisun Select cells, ^� I Sand 5 busbar options available IIII Frame Anodized or powder coated aluminum alloy Glass Tempered(low-iron),anti-reflective coating 3 burr cell Junction Box NEMA IP67 rated.3 internal bypass diodes Cable&Connectors 12 AWG(4 mm*)PV Wire cable with multiple connector options available:cable length approx.1000 mm 11 MECHANICALS • Cells.Module 60(6 x 10) 5 busbar cell Module Dimensions 1660 x 990 mm(65.35 x 38.98 in.i I Module Thickness(Depth) 35 mm(1.37 in.) Approximate Weight 17.9+1-0.25 kg.(39.5+1-0.51b.) PV module:Suniva,OPT285-60-4-100 ------ --- -- - - _- currenFVdtage Ov)as a Function ofIsolabon Wm')and Ternperatue TEMPERATURE COEFFICIENTS 1z- c.r1:m0 2i c voltage 9 3.Voc(°1Gl°C) ,-0.336 10'Iro°areha°.-1ocOWin, 295.0w - Ourer'• -7.lac(%1°C) +0.047 8-inoere krsa.900 wmr 2292 w - --- -- ----r- a Power y,Pmax(96/°C) i-0.420 s 6.1ro0..e rra0.9ao w+r maw - NOCT Avg - (+,.2 C 46.0- 4,iro0na 1996-490 wmr 11421. 2,'mow Wad._203Wine 557w LIMITS o Max.System Voltage j 1000 VDC for IEC. 1000 VDC for UL 0 5 10 15 20 25 30 35 40 ._.� V019194 M Max Series Fuse Rating 15 Amps SuOperating Module Temperatte's ' -40°C to+85°C(-40°F to+185°F) 100% [rtiN/lo 97%-".". :14 s, Storm Resistance Static Load Tested to IEC 61215 for loads of 5400 Pa(113 psfl: FRFN�Ii hafland wind resistant -- ----- - -- - _-.. i v0%. RM�'V ±Z . S vva$reserves the,;ht to change the data at any time ,c..1 ^ar:.a a!suniva.c.-- hAR�/N 'UV 90 kWh.TC 400.OH 2000. =Tests were conducted on modure type OPT 6C silver frame. STANDN IY Rq,yTG 80%• Please read installation manual before installing or working with module. 0 1 12 25 ETPAI A F 5 HEADQUARTERS ' . ,.els Total - oeac^ree ^;-so a.B44 •53 modules "" +;'� PLEASE RECYCLE *voas Cw0rv.a30092USA un'va OPT•60 cell 25 36 °! •1 404 4'-2700 AUGUST 10.2015(REV 1) [SAMD_0061j sAer arc 5acK www.suniva.com 're 5n•hence o+wu.MOO.Sem.We•