270 6TH ST - SOLAR SYSTEM 1
♦ r y Jlv4
y ,__ f CITY OF ATLANTIC BEACH
J" !1 s) 800 SEMINOLE ROAD
0'1 =" ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
iN
ELECTRICAL PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 16-ELEC-1447
Job Type: ELECTRIC ONLY
Description: INSTALL SOLAR PV SYSTEM
Estimated Value: $400.00
Issue Date: 7/7/2016
Expiration Date: 1/3/2017
PROPERTY ADDRESS:
Address: 270 6TH ST
RE Number: 172562-0000
PROPERTY OWNER:
Name: YEATS, ALEXANDER
Address: 270 6TH ST
GENERAL CONTRACTOR INFORMATION:
Name: BEACON ELECTRICAL CONTRACTORS
Address: 1428 CRYSTAL SAND DR SHAWN HEATH
Phone: - -
FEES:
State Elec DBPR Surcharge $2.00
State Elec DCA Surcharge $2.00
Electrical Repairs $35.00
Trade Permit Base Fee $55.00
PLAN CHECK FEES $27.50
Total Payments: $121.50
PERMIT IS APPROVED ONLY IN ACCORDANCE WITII ALI. CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
S.-�,yr City of Atlantic Beach APPLICATION NUMBER
JS j
l Building Department (To be assigned by the Building Department.)
J� A8tla tic Beac RoadIt _ — 4ter'' r! Atlantic Beach, Florida 32233 5445
Phone(904)247-5826 • Fax(904)247-5845
E-mail: building-dept@coab.us Date routed: i
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: Z7 CD c S ( D ment review required Yes o
,� . —� _ Buildin V
Applicant: —FLU/V T j Q Tng &Zoning
• Tree Administrator
Project: SoL_FAK P V 1�S'1"F, ctil Public Works
Public Utilities
-
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept.of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: L Approved.
['Denied.
(Circle one.) Comments:
BUILDING
PLANNING &ZONINGn- //
Reviewed by: Date: / /'
TREE ADMIN.
Second Review: Approved as revised. ❑Denie y
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
Comments:
Reviewed by: Date:
Revised 05/14/09
LILDING PERMIT APPLICATT 'N
CITY OF ATLANTIC BEACH
800 Seminole Road, Atlantic Beach, FL 32233 FILE COPY
Office (904) 247-5826 Fax (904) 247-5845
;,obAddress: Drib Lip ce Permit Number: a -L'/L--L -` /L1y7
Legal Description [F) k of\Is' c )9E. IIc Parcel# i c) 51pa. (X)00Floor Area of Sq.Ft. 'q.Ft
Valuation of Work$ t'l5b.( D Proposed Work heated/cooled non-heated/cooled
Class of Work(circle one): Addition Alteration Repair Move Demolition pool/spa window/door
Use of existing/proposed structure(s) (circle one): Commercial a_esidentiaLM
If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No
Florida Product Approval # CLQ � le.e_is)
For multiple products use product approval form \
Describe in detail the type of work to be performed: k(�( �V coke.,-,-1/4- 1-coke.,-,-1/4- 1-Y1 Si-Q l I
Property Owner Information:
Name: P\ exo, /of \ e..QI B Address: O`-] b L1244-) S-t.
City A i i.- >.' . J State R`.Zip372 Phone 71)-2D21 - l-2-)(13
E-Mail or Fax#(Optional) .3 A eats Q nc d(. cr)(Y1
Contractor Information:
Company Name: A-1A Qr- e cfac+(
OTT-J(-Qualyning Agent: 3, 2f
\ )t(t i lC%
Address:H>-1 2 `tib Yqd.4 I nif DY)) Ci State F 'Zip
(40'lice Phone D'-i-l-ItsQ IO Job Site/Contact Number IN-y(p - 1 jp Fax#
Mate Certification/Registratio # V Q.. '7r
1
Architect Name& Phone#
Engineer's Name& Phone# Dee R MOlt c.(1 el(0
Fee Simple Title Holder Name and Address NI. A
Bonding Company Name and Address j\L. F}
Mortgage Lender Name and Address k (4
Application is hereby made to obtain a permit to do the work and installations as indicated I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null
and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6)months at any time after
work is commenced. I understand that separate permits must be secured for Electrical Work, Plumbing,Signs, Wells,Pools, Furnaces,Boilers, Heaters,
Tanks and Air Conditioners,etc
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDINGYOUR.NOTICE OF
COMMENCEMENT. ,F.. ``!4;:, VIRGINIA ANNA JADA
MY COMMISSION#FF991573
I herebycertify that I have read and examined this a plication and know the same to be true and correct. All pro isie , 'aws af�X6Hd&&hdAt gizV (ng this
type ofworkwill be complied with whether speci ted herein or not. The granting of a permit does not presu &ola3 itib uthoroa gid incel me
provisions of any other federal,state, or local law regulating construction or the performance of construction.
Signature of Owner /,g,��• Signature of Contractor // -----
Print Name [e y,e,,•,-`<S--e_4- 111 e. Print Name ------/-7TC42!,C_th 5
•
,""''Day o
sobscfibe before . 0 I V; this me Sworn Dayf .subscribed
s1W(\-Q-
W(\- -before me
_ ., ,20 �G
ii-I^1 C , ` - tit a,' r Lc � " �c Ui/n..viio a J�
Notary ' •lic w .��
' ' ' ' ION#FF991 3 No ubIic
� ': ''
'?o.Rr EXPIRES May 11,2020
(407)398-0153 F)o/ballolarySatme.com Revised 01.26.10
ECTRICAL PERMIT APPLICATION FILE COPY
CITY OF ATLANTIC BEACH
0 800 Seminole Rd, Atlantic Beach, FL 32233
• Ph(904) 247-5826 Fax (904) 247-5845 ¶ —` .( 447
JOB ADDRESS: @'1i7 tp ce f " hkkan -eagath FL, ?j22 3 PERMIT #t
JEA INFORMATION REQUIRED ON ALL PERMITS aOb AMPS cq4C) VOLTS3 PHASE
VALUE OF WORK$ 14.co
NEW SERVICE ❑ Overhead ❑ Underground ❑1 Underground up Pole
Residential(Main) Service
0-100 amps 101-150amps 151-200amps amps #of Meters
Commercial(Main)Service
0-100 amps 101-150amps 151-200amps amps CT Service amps
Conductor Type Size
Multi-Family(Main)Service
0-100 amps 101-150amps 151-200amps amps #of Unit Meters
Temporary Pole amps
SERVICE UPGRADE amps CT Service amps
NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.)
100 amps 150amps 200amps amps CT Service amps
ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC.
Outlets/Switches: 0-30amps 31-100amps 101-200amps
Appliances: 0-30amps 31-100amps 101-200amps
A/C Circuits: 0-60amps 61-100amps
Heat Circuits: # circuits @ kw
Number of Lighting Outlets, Including Fixtures:
OTHER ELECTRICAL PROJECTS
Swimming Pool Sign Smoke Detectors_Qty Transformers KVA Motors hp
FIRE ALARM SYSTEM (Requires 3 sets of plans & Fire Alarm Checklist)
Qty volts/amps VALUE OF WORK$
REPAIRS/MISCELLANEOUS
ReplaceBuurnt/Damaged Meter Can Safety Inspection Panel Change OH to UG
)ether: C3Okek( v CjlAs 'P.(Y1 1.•11S-kOQ1 t
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have
read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether
specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of
construction.
AI
Property Owners Name .,a401- fir Phone Number r 7a-3a L— l 3"1n
3
Electrical Company .E( c k 'i CC0.1 Cbik.cc thi' ,Tne._, Office Phone-339.-5.SW Fax
Co. Address:l3'1)1AUQ.1 9ikci'tN0 pd. Ste.IO7-sNo City-5Qa5D(1Uc`le_ State (_.Zip 2 1B
License Holder (Print):— , State Certification/Registration#
Notarized Signature of License Holder ' S5 A
Sworn and subscribed before me this 1G day of JUJU_ 20 i i.p
;y�✓"'"�;: VIRGINIA ANNA JADA
=' •'E MY COMMISSION#FF991573
a EXPIRES May 11,2020
.07)396-0153 Flaida$ot.ryS.,nq.co,ll
ELECTRICAL PERMIT APPLICATIO
LI
CITY OF ATLANTIC BEACH Pe',"
t 800 Seminole Rd, Atlantic Beach, FL 32233 FILE CC(
r-� hPh (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: D ! V � -c et-, 1"mak rvj C fin- t t. a PERMIT #
Signature of Notary Public 'V AA ae1cZ
,
--------------
460
4
W �.,
Z1-1
JJ
L^` W
^W c 1_ I
, W
FILE COPY
N N < N
N
N (B c4 ':
v
._
o J 4. N
o o �
CC e x N
C NI
M•
O — M
N = Q1
CD "
v
a)
r� r co 0
a.�, �" r:. ase y .. o O 1
,e: .
N • ■
• 4%, i
V
Ca
4.4
E
cu
J Ii
{4 ., '/ LL-
At" °•
y +"+r '`'+". fir•'
oVIII 0
0
i1 c
a REVIEWED FOR CODE COMPLIANCE O
CITY OF ATLANTIC BEACHQ
v SEE PERMITS FOR ADDITIONAL
N N REQUIREMENTS AND CONDITIONS c! %=
rt REVIEWED BY: DATE: 7 / '�G Lo Li)O
O VI
I\
—______ N
•
•
/ M . O
O 0 u /��/�" O cD O N M
v u 2 N , t0N }' I I
i +,,; O 7 0Zf Vv O N 41 CU
t >- a_
on U Lt.) C N ` " N
u
iJ in i •--� .. Y v, c op to ..Y
v0- 7 O V) y ,It � 0O v �_
C� U ccX C C Z m CC� �n t 0 4! fV
C 0 o o G N m 0 Q Q Q Q r'_-'!% .�lr G cC LL /n In co
V
iiU BUILDER PROJECT REPORT
VFRSION.
JUN 14,2016.06:35 PM
PROJECT TITLE: 8.55 KW RESIDENTIAL
PROJECT ID: 222C8FF4
Name: Yeats Residence Designed by None
Address: 270 6th Street SOLARMOUNT
City,State: Atlantic Beach,FL,32233 30-280 Watt Panels
Module: Suniva OPT280-60-4 35mm 531 Sq Ft.
280 Watts 8.4 kWs
INSTALLATION AND DESIGN PLAN
LAYOUT WORKSPACE
1 2 3 4 5 6
1 238.1
2 238.1
Array vertical dimension:130.7
Array horizontal dimension:238.1
Row Modules Zone Rail Type Splices Roof Attachments
6 zo"e 1 SM RAIL 240"MILL 320240M I$101 (2) 0 12
2 6 SM RAIL 240"MILL I 320240M I$101 (2) 0 12
Maximum Rail Span(Zone 11: 105.00"
Selected Rail Span: 48.00"
Maximum Rail Cantilever: 16.00"
Module Orientation: Portrait
Rail Direction: EW
`Zone 2 and 3 Rail Spans must be independently verified
• _____._._______.
LAYOUT WORKSPACE 2
1 2 3 4 5 6 7 8 1
1
355.E
2 355.6
Array vertical dimension:130.7
Array horizontal dimension:355.8
Row Modules Zone Rail Type Splices Roof Attachments
SM RAIL 168"MILL I 320168M I$70(2)
1 9 zone SM RAIL 240"MILL 1320240M I$101 (2) 2 16
SM RAIL 168"MILL I 320168M I$70(2)
2 9 Zone 1 SM RAIL 240"MILL 1320240M I$101 (2) 2 16
Maximum Rail Span(Zone 1"): 105.00"
Selected Rail Span: 48.00"
Maximum Rail Cantilever: 16.00"
Module Orientation: Portrait
Rail Direction: EW
'Zone 2 and 3 Rail Spans must be independently verified
2111 U-BUILDER PROJECT REPORT
VERSION:1.2 13
JUN 14,2016,06:35 PM
PROJECT TITLE: 8.55 KW RESIDENTIAL
PROJECT ID: 222C8FF4
Name: Yeats Residence Designed by None
Address: 270 6th Street SOLARMOUNT
City,State: Atlantic Beach,FL,32233 30-280 Watt Panels
Module: Suniva OPT280-60-4 35mm 531 Sq Ft.
280 Watts 8.4 kWs
ENGINEERING REPORT
Plan review Inspection
Product: SOLARMOUNT
Loads Used for Design Module Manufacturer: Suniva
-Building Code: ASCE 7-10 Model: OPT280-60-4 35mm
-Wind Speed: 125 mph Module Watts: 280 watts
-Ground Snow Load: 0 psf Module Length: 65.35"
-Seismic(Ss): 0.11 Module Width: 38.98"
-Wind Exposure: C Module Thickness: 1.38"
Loads Determined by Zip Expansion Joints: Every 40'
-City,State: Atlantic Beach,FL Rails Direction: EW
-Wind Speed: 125 mph Building Height: 30 ft.
-Ground Snow Load: 0 psf Roof Type: Shingle
Total Weight: 1185.00 lbs
r 0 "4111►
WORKSPACE 1
Roof Point Load Up: _198 lbs Maximum Rail Span(Zone 1):
Roof Point Load Down: 159 lbs Selected Rail Span:
Maximum Rail Cantilever: 16.00"
Total Number of Modules: 12 Roof Pitch: 6:12
Total KW: 3.4 KW
Rows/Columns: 2/6(no gaps)
NS Dimension: -10.9 ft
EW Dimension: -19.8 ft
1,11lnPv CDA.C',F '
Roof Point Load Up: -198 lbs Maximum Rail Span(Zone 1):
Roof Point Load Down: 159 lbs Selected Rail Span:
Maximum Rail Cantilever: 16.00"
Total Number of Modules: 18 Roof Pitch: 6:12
Total KW: 5.0 KW
Rows/Columns: 2/9(no gaps)
NS Dimension: -10.9 ft
EW Dimension: -29.7 ft
z A.-n.r
ULO
IC RI-
(-) r LL W
m
N N 4 N
Ce ce J `
QN
O O ,5O � N
Ni
CCC N
o .- m
2
�"+ m
-
V ` N
a
•. - .414.04111114.... ,
= N
0 • -
•
N
••+
a •
al
„5,6Z a
• •• Iz •
LI) 1111 .• ,
Lr~• y m C
CO Ni
0
—
+ + CD
CL
-I-, ccU
4-; •
•• (NI
1
CT3 CU
Irl
W Ce
O 1-r)
r
O O
a
vi
O03 H
" O M° VD N_ N M
u u in Q .Ni E •• H
O 7 o2S u O� N N ca vlL
a c > v Ln N L N a
— ..• 7 O is) U •t L_ O E r° W C 110 u
.u-cu N c a
C U > X i C Z m `� ''',...,j
v p r0 > v = ra m
G O O 2 vv) az 0 Q Q Q Q 7 cL rr C to N M
) t't2"
Se
. .
.r ' i,
a�
r:
2,•••' , /
t
,
Enphase' Microinverters
Enphase M250
n b
6 ti 4
Thenphase- M250 Microinverter delivers increased energy harvest and reduces design and
installation complexity with its all-AC approach. With the M250. the DC circuit is isolated and insulated
from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This
further simplifies installation, enhances safety. and saves on labor and materials costs.
The Enphase M250 integrates seamlessly with the Engage Cable, the Envoy Communications
Gateway'', and Enlighten . Enphase's monitoring and analysis software.
PRODUCTIVE SIMPLE RELIABLE
-Optimized for higher-power - No GEC needed for microinverter -4th-generatior product
modules - No DC design or string calculation - More than 1 million hours of testing
- Maximizes energy production required and 3 million units shipped
- Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25
dust, and debris Cable years
�e y enphkase
c us
Enphase°M250 Microinverter/I DATA
INPUT DATA(DC) M250-60-2LL-S22/S23/S24
Recommended input power(STC) 210-300 W
Maximum input DC voltage 48 V
Peak power tracking voltage 27 V-39 V
Operating range 16 V-48 V
Min/Max start voltage 22 V/48 V
Max DC short circuit current 15 A
Max input current 9.8 A
OUTPUT DATA(AC) 0208 VAC 7240 VAC
Peak output power 250 W 250 W
Rated(continuous)output power 240 W 240 W
Nominal output current 1.15 A(A rrrts at nominal duration) 1.0 A(A rms at nominal duration)
Nominal voltage/range 208 V!183-229 V 240 V/211-264 V
Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz
Extended frequency range' 57-62.5 Hz 57-62.5 Hz
Power factor >0.95 >0.95
Maximum units per 20 A branch circuit 24(three phase) 16(single phase)
Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles
EFFICIENCY
CEC weighted efficiency,240 VAC 96.5% —�
CEC weighted efficiency,208 VAC 96.0%
Peak inverter efficiency 96.5%
Static MPPT efficiency(weighted,reference EN50530) 99.4 %
Night time power consumption 65 mW max
MECHANICAL DATA
Ambient temperature range -40°C to+65°C
Operating temperature range(internal) -40°C to+85°C
Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket)
Weight 2.0 kg
Cooling Natural convection-No fans
Enclosure environmental rating Outdoor-NEMA 6
FEATURES
Compatibility Compatible with 60-cell PV modules.
Communication Power line
Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in
NEC 690.35. Equipment ground is provided in the Engage Cable. No
additional GEC or ground is required.
Monitoring Free lifetime monitoring via Enlighten software
Compliance UL1741/IEEE1547,FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91,
0.4-04,and 107.1-01
Frequency ranges can be extended beyond nominal if required by the utility
To learn more about Enphase Microinverter technology, enphase
visit enphase.cotr; � c N E it G Y
C 2013 Enphase Energy.All rghts reserved.Al trademarks or brands s n this document are registered by thew-espective owner.
1.1
W
o v
TpT
my
T G ^xy
cy 2
A — 1 /
2II
.I ._ Uf illi:.. 0
;
ill
/ °2F.r £� .s
a st _� g
x
1, _
1
2 r
Wei
n$ d 4 ;_ , � 1 1 / —` 'imams
40111111111101111111
• k 1101001111110a a n I: 1000101111
100010111
mew
AMMONS
-U■li...
— 11111111111111111111
�aU$s11S11
•
827 0..
W ! /1 r
gi /
02§ / ..
I
� _
A
Ai S /
Y 0
A-
x c 1
NAm Fx .
E; Zz3
m 2
D
S
rn _
a — 0
•
koN
Suniva
SUNIVA OPTIMUS- SERIES
MONOCRYSTALLIHESOLAR MODULES
OPT SERIES:OPT 60 CELL MODULES(BLACK FRAME)
Optimus modules are known for their superior quality
and long-term reliability.These high-powered modules
ENGINEERING EXCELLENCE
consist of Suniva's premium ARTisun'Select cell technology
• Built exclusively with Suniva's premium ARTisun and are designed and manufactured in the U.S.A.and North
Select cells,providing one of the highest power America using our pioneering ion implantation technology.
outputs per square meter at an affordable price
Suniva's high power-density Optimus modules provide
■ The leading US-born.US-operated crystalline excellent performance and value.
silicon cell and module manufacturer,spun out
of Georgia Tech's University Center of Excellence >s
in Photovoltaics;one of only two such research FEATURES
centers in the U.S. f
• Utilizes our premier American-made cell
■ Suniva's state-of-the art manufacturing and module technology,ARTisun Select
lab facilities feature the most advanced equipment
and technology • Superior performance and reliability:enhanced
stress tests conducted at Fraunhofer ISE
QUALITY & RELIABILITY
• Module families ranging from 275-285\V
■ Suniva Optimus modules are manufactured and
warranted to our specifications assuring consistent • Marine grade aluminum frame
high performance and high quality with hard anodization or powder coating
• Rigorous in-house quality management tests beyond
standard UL and IEC standards • Certified PID-free by PV Evolution Labs(PVEL)
• Performance longevity with advanced • Made in North America
polymer backsheet
• UL1703 listed Type 2 PV module • Qualifies for Ex-Im Financing
• Passed the most stringent salt spray test • 1000 'CI,
based on IEC 61701
Passed enhanced stress tests based on IEC 61215 • 25 year linear power warranty;
• conducted at Fraunhofer ISE' 10 year product warranty
• PAN files are independently validated
CERTIFICATIONS
MANUFACTURED N1r i ' $ ORIEL
Georgia & Michigan
www.suniva.com
V7.
v 0
J
v csi
CLOD 0
r_ = N
Q - N
i :; O
r+ r•
0 2 a �
CZ '
- a
ZN
40a O
F_Q
L
V J
•— (./1
c f
Z wLn
z Ln
-o '
L_ N
ro O
> i.N
CU
t CO
j� O
mz
•/%::% A�1
>,
1 t CU
M
. l - w
r
l r0 Q1
O
L cr
.4 r m
p
c: -CI
Z
A
0
s i 1111::°4 S"
0 IX
i
, IX L'Z <
,
.
I 1 - DN.
■.■
. - 111111
I-
CDs
4.1
C7
Z c 7. in
IU 1 151)
0 R 4L
a, as 1 i C ! 1
w Ii I
Z ,o
E a,
0
Z p p f \ L
LA 4, s
�4•1 X II I
Z as p j W
I
I
a'
ca s
I
IL +'•LL 3 v) am TA CD •L.
4,
L
C LL L ( t11 I
j
Z •N 0
Z L s II
%A., 11 c ill
a ca ca p0 , t I,I C `*' .0Q ca c J to O (5 ,. . i
LL ++ LL �1 ,
V p CO / 1 '
. ` ' •3 I
� L d LL ' LL 3
O c H
s s
Z ++ I s m
D al IR L f �' c 1
Z � � Lu1I , , / cu y � ,
J
� 1 V It iti1 , cs
_, ••
Q e_ N M
F- Q. a. O.
a) cu a)
Z N V) N
C
O
(0
O
-.0
C
4-,
-o
(0
C
E
u
O
>,
+J
C
(0
(0
C
a)
u
0
E
O
u
u
(0
I
Z �
Q \
IX Q
-C
N
N
1
SOLARMOUNT Technical Datasheets :I:U N I RAC
SOLARMOUNT Technical Datasheet
Pub 130817
SOLARMOUNT Module Connection Hardware 1
Bottom Up Module Clip 1
Mid Clamp 2
End Clamp 2
SOLARMOUNT Beam Connection Hardware 3
L-Foot 3
SOLARMOUNT Beams 4
SOLARMOUNT Module Connection Hardware
SOLARMOUNT Bottom Up Module Clip
Part No. 302000C
Washer • Bottom Up Clip material: One of the following extruded aluminum
Bottom Nut (hidden..s,e alloys: 6005-T5, 6105-T5, 6061-T6
1 Up Clip no , • Ultimate tensile: 38ksi, Yield: 35 ksi
* • Finish: Clear Anodized
/.‘4 • Bottom Up Clip weight: —0.031 lbs (14g)
Beam % Bolt • Allowable and design loads are valid when components are
\ assembled with SOLARMOUNT series beams according to
ii ---.. .... , _.
authorized UNIRAC documents
• Assemble with one 1/4"-20 ASTM F593 bolt, one 1/4"-20 ASTM F594
serrated flange nut, and one 1/4"flat washer
\ • Use anti-seize and tighten to 10 ft-lbs of torque
• Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third-
- party test results from an IAS accredited laboratory
• Module edge must be fully supported by the beam
* NOTE ON WASHER: Install washer on bolt head side of assembly.
DO NOT install washer under serrated flange nut
Applied Load Average Allowable Safety Design Resistance
Direction Ultimate Load Factor, Load Factor,
lbs(N) lbs(N) FS lbs (N) m
�- Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662
YTransverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441
0-X 0 Sliding,Z± 66(292) 27(119) 2.44 41 (181) 0.619
Dimensions specified in inches unless noted
111
r 1
SOLARMOUNT Technical Datasheets ::: UNI RAC
SOLARMOUNT Beam Connection Hardware
SOLARMOUNT L-Foot
Part No. 304000C, 304000D
• L-Foot material: One of the following extruded aluminum alloys:6005-
T5, 6105-T5, 6061-16
• Ultimate tensile: 38ksi,Yield: 35 ksi
�� • Finish: Clear or Dark Anodized
-.:
• L-Foot weight: 0.215 lbs(98g)
• Allowable and design loads are valid when components are
Bea r ...410011assembled with SOLARMOUNT series beams according to authorized
/ Bolt UNIRAC documents
�'' L-Foot • For the beam to L-Foot connection:
•Assemble with one ASTM F593%"-16 hex head screw and one
•
Oerrate•
'• ASTM F594'/8"serrated flange nut
Flange N •Use anti-seize and tighten to 30 ft-lbs of torque
• Resistance factors and safety factors are determined according to part
1 section 9 of the 2005 Aluminum Design Manual and third-party test
Y results from an IAS accredited laboratory
NOTE: Loads are given for the L-Foot to beam connection only; be
X sure to check load limits for standoff, lag screw, or other
attachment method
,oi Applied Load Average Safety Design Resistance
3%SLOT FOR Direction Ultimate Allowable Load Factor, Load Factor,
`."ARDWAR! lbs(N) lbs(N) FS lbs(N) m
:o: -
Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646
Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575
Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615
Traverse,X± 486(2162) 213(949) 2.28 323(1436) 0.664
r .
SOLARMOUNT Technical Datasheets U N I RAC
SOLARMOUNT Beams
Part No. 310132C, 310132C-B, 310168C, 310168C-B, 310168D
310208C, 310208C-B, 310240C, 310240C-B, 310240D,
410144M, 410168M, 410204M, 410240M
Properties Units SOLARMOUNT SOLARMOUNT HD
Beam Height in 2.5 3.0
Approximate Weight(per linear ft) plf 0.811 1.271
Total Cross Sectional Area in2 0.676 1.059
Section Modulus(X-Axis) in3 0.353 0.898
Section Modulus(Y-Axis) in3 0.113 0.221
Moment of Inertia(X-Axis) in° 0.464 1.450
Moment of Inertia(Y-Axis) in° 0.044 0.267
Radius of Gyration(X-Axis) in 0.289 1.170
Radius of Gyration(Y-Axis) in 0.254 0.502
'Rails are extruded using these aluminum alloys: 6005-T5, 6105-T5, 6061-T6
I
SLOT FOR T-BOLT OR 1.728
1/4" HEX HEAD SCREW SLOT FOR T-BOLT OR
/a"HEX HEAD SCREW
2X SLOT FOR 1 SLOT FOR
BOTTOM CUP al
2.500 BOTTOM CUP
T ifiAr 3.000
N1.3316
SLOT FOR
!Li
' SLOT FOR 1.3853/3" HEX BOLTLim i
3e
" HEX BOLT 1 1
.387
.750 L 1.207
Y Y 1.875
A A
►X ►X
SOLARMOUNT Beam SOLARMOUNT HD Beam
Dimensions specified in inches unless noted
4
r R
SOLARMOUNT Technical Datasheets ::' UNI RAC
SOLARMOUNT Mid Clamp
Part No.302101C, 302101D.302103C, 302104D.
3021050. 302106D
• Mid clamp material: One of the following extruded aluminum
\ ra - • \� Bolt alloys: 6005-T5, 6105-T5, 6061-T6
Mld 1�1a •e N _
Camp �„ • Ultimate tensile: 38ksi, Yield: 35 ksi
~ • Finish: Clear or Dark Anodized
�. • Mid clamp weight: 0.050 lbs(23g)
`
\ -.. • Allowable and design loads are valid when components are
assembled according to authorized UNIRAC documents
1;114
• Values represent the allowable and design load capacity of a single
mid clamp assembly when used with a SOLARMOUNT series beam
to retain a module in the direction indicated
•
N
• Assemble mid clamp with one Unirac%"-20 T-bolt and one'/4'-20
ASTM F594 serrated flange nut
Use anti seize and tighten to 10 ftlbs of torque
Beam
• Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third-
party test results from an IAS accredited laboratory
• Applied Load Average Allowable Safety Design Resistance
1.00 DISTANCE - - Direction Ultimate Load Factor, Load Factor,
BETWEEN MoouLEs lbs(N) lbs(N) FS lbs(N) m
Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667
iI
� - - Transverse,Z± 520(2313) 229(1017) 2.27 346(1539) 0.665
Sliding, X± 1194(5312) 490(2179) 2.44 741 (3295) 0.620
►X
Dimensions specified in inches unless noted
SOLARMOUNT End Clamp
Part No.302001C,302002C,302002D,302003C,
302003D,302004C,302004D,302005C,302005D,
302006C,302006D,302007D,302008C,302008D,
302009C,302009D,302010C,302011C,302012C • End clamp material: One of the following extruded aluminum
alloys: 6005-T5, 6105-T5, 6061-T6
i� :oft • Ultimate tensile: 38ksi, Yield: 35 ksi
�%iit • Finish: Clear or Dark Anodized
.
__->"-------:_..---3\
• End clamp weight: varies based on height: —0.058 lbs (26g)
End Clamp • Allowable and design loads are valid when components are
rrate• IP° / assembled according to authorized UNIRAC documents
Flange Nut • Values represent the allowable and design load capacity of a single
end clamp assembly when used with a SOLARMOUNT series beam
to retain a module in the direction indicated
• Assemble with one Unirac 1/4"-20 T-bolt and one'/4'-20 ASTM F594
i
serrated flange nut
�i�Bea `x111': • Use anti-seize and tighten to 10 ft-lbs of torque
\ r, • Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third-
Y ,4 party test results from an IAS accredited laboratory
A • Modules must be installed at least 1.5 in from either end of a beam
►X
I.s Applied Load Average Allowable Safety Design Resistance
MINIMUM' Direction Ultimate Load Factor, Loads Factor,
' -- lbs(N) lbs(N) FS lbs(N) 0
HEIGHT --_I
VARIES
TH• S Tension,Y+ 1321 (5876) 529(2352) 2.50 800(3557) 0.605
MUOIN.E
THICKNESS Transverse,Z± 63(279) 14(61) 4.58 21 (92) 0.330
Sliding,X± 142(630) 52(231) 2.72 79(349) 0.555
Dimensions specified in inches unless noted
zc
(f) •�
r-
>
n
DT
O
zo „
o D
o �
z �•
1
I
N
# �`
13{
. . i I \ =1 =
." — 1 \ \. m
. 4 ' -\I f ' ,
i ;
a
cC
cr
l......i 1, • li 1 al re'T
gi
i I I jvow O
. ,.,. fe...
i ') '
f I A M CD
O
1 ! t10PAJI
I%, i t. i
j rt.
CD
�' e'' p
771 1
['I."
0.
� {1l a I
O
A UJ N F+t
o su r m r `=
aro=• = aI o o1. v CM3.
°1 r, r* o
, 3 s ,-. o rt
m D m * M
ro _ mi — ro r. C.
ID
o c ^ rp 1+
3 :°
? -rj -o CU
0
n < O
ro a 7
ro
a
I
-0 5
ssC *• m Z ( -I 3 * o C g -1 • h c
_
O � zr -.r -p O -p Cu r+ -1 • .f v ' g
v + '^ v 7• s -, -I N ,-* • -z s CDq
cnv _0 � OOOQ Cr+ 2- v O � n' w' R
(D c a) c O_ '� p _ cu-, Q
0
•
N' O 0 .-.. no -
'+ D N c n 7- O (CD c C J C- O i N • 1��
c �. 'l, o Cl N Q (D CO • r�r c D
v0 , -, rt C -. O0 in' .�+ (O p Or+ (D O -8 D v ck
,+ c .- -n O O_ n n D p r+• - cD Z
c o v o 0 o cQ C �' (ND vpi '^
3 O. O_ O y 0 N ' O O (�
D (D5. 3- rte+ Lv 3 O N N �-, o
•* (D (Q
c▪ • o C (0 Z z (D D S �' -h (D O_ (D 0 -
R. O < n + .-I. -0 O �, O n v
0 r+ 3 D p 3 ' o
n N (DD v Z O v --� v v +
C e
O_ v, n N v -4 a) v CD 3 D ,-/' `<
O CD m 7 70 Cr CO (,12 (D O_ 0 D v O�
v rN+ v C "_ p 7 C (Q o C `< 3
O O (D VI N (D
8O O _ (D O_ O_ Q_
`� • v �. (D .-1. n {(D , '+ O <
cn CO (D D' o O_ p r* .
CU + _
, O O_ < O D D- (D r+ S
p'-p O_ CDD (D S vi O
D-
(D o v
,+ p CO -, E
z O (D v
1
Ni 00 O y -, K C
O O (p -n : cc CT �'
v)• Oy N•.� 0 v co nc
(D a) D m 3 CO CO p
Ca_ O N Z`� �
O
Q O S W CO C
CD - (DV (D
M D o <
o o C1 �,
S
T 1,+ 7 o v) Z
Q D -i CTIm
(D O CD en
•(D < ,•+ (D
CD to •-(‘
o (D
cD O_
LIT �
CO n
0- C
0 O-
,i• (D
O_
,+ v
v
-0 D
(0 O_
...� G,1 - OPTIMUS SERIES: OPT 60 CELL MODULES
•. i ELECTRICAL DATA(NOMINAL)
The rate). ..,ay only v r 0y a.-2.5'Aic and a:'Other eiectr,-^a?: •A•rete.,c
s e r v 1 Model Number OPT275 OPT280 OPT285
v
A 60-4-180 60-4-1B0 60-4-180
4Power Classification(Pmax) 275 W 280 W 285 W
°
4w•°•+Mw 1 Module Efficiency(%) 16.73% 17.04% 17 34°,
Voltage at Max.PowerPoint(Vmp) 32.0 V 32.1 V 32.2 V
b} Current at Max.Power Point(Imp) 8.59 A 8.72 A 8.84 A
r 1
• '� Open Circuit Voltage(Voc) 39.1 V 39.2 V 39.2 V
Short Circuit Current(lac) 9.34 A 9.47 A 9.61 A
The etectncar data cooly to standard test conaitons t$TC1:Irradiance of 1000 Wirt'with AM 1.5 spectra at 25-C.
CHARACTERISTIC DATA
Type of Solar Cell j High-efficiency ARTisun Select cells, ^�
I
Sand 5 busbar options available
IIII Frame Anodized or powder coated aluminum alloy
Glass Tempered(low-iron),anti-reflective coating
3 burr cell Junction Box NEMA IP67 rated.3 internal bypass diodes
Cable&Connectors 12 AWG(4 mm*)PV Wire cable with multiple connector
options available:cable length approx.1000 mm
11 MECHANICALS •
Cells.Module 60(6 x 10)
5 busbar cell Module Dimensions 1660 x 990 mm(65.35 x 38.98 in.i
I Module Thickness(Depth) 35 mm(1.37 in.)
Approximate Weight 17.9+1-0.25 kg.(39.5+1-0.51b.)
PV module:Suniva,OPT285-60-4-100 ------ --- -- - - _-
currenFVdtage Ov)as a
Function ofIsolabon Wm')and Ternperatue TEMPERATURE COEFFICIENTS
1z-
c.r1:m0 2i c voltage 9 3.Voc(°1Gl°C) ,-0.336
10'Iro°areha°.-1ocOWin, 295.0w -
Ourer'• -7.lac(%1°C) +0.047
8-inoere krsa.900 wmr 2292 w - --- -- ----r-
a Power y,Pmax(96/°C) i-0.420
s 6.1ro0..e rra0.9ao w+r maw
-
NOCT Avg
- (+,.2 C 46.0-
4,iro0na 1996-490 wmr 11421.
2,'mow Wad._203Wine 557w LIMITS
o Max.System Voltage j 1000 VDC for IEC. 1000 VDC for UL
0 5 10 15 20 25 30 35 40 ._.�
V019194 M Max Series Fuse Rating 15 Amps
SuOperating Module Temperatte's ' -40°C to+85°C(-40°F to+185°F)
100% [rtiN/lo
97%-".". :14 s, Storm Resistance Static Load Tested to IEC 61215 for loads of 5400 Pa(113 psfl:
FRFN�Ii hafland wind resistant
-- ----- - -- - _-..
i v0%. RM�'V ±Z . S vva$reserves the,;ht to change the data at any time ,c..1 ^ar:.a a!suniva.c.--
hAR�/N 'UV 90 kWh.TC 400.OH 2000. =Tests were conducted on modure type OPT 6C silver frame.
STANDN IY Rq,yTG
80%•
Please read installation manual before installing or working with module.
0 1 12 25 ETPAI
A F 5 HEADQUARTERS
' . ,.els Total - oeac^ree ^;-so a.B44
•53 modules ""
+;'� PLEASE RECYCLE *voas Cw0rv.a30092USA un'va
OPT•60 cell 25 36 °! •1 404 4'-2700
AUGUST 10.2015(REV 1) [SAMD_0061j sAer arc 5acK www.suniva.com 're 5n•hence o+wu.MOO.Sem.We•